Loading...
Permit q CITY OF TIGARD MASTER PERMIT I. • COMMUNITY DEVELOPMENT Permit#: MST2014-00125 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/18/2014 T t t, A R L7 g Parcel: 2S110BA08800 Jurisdiction: Tigard Site address: 14225 SW 116TH TER Subdivision: EVERGREEN SPRINGS Lot: 13 Project: Jirles Project Description: Installation of residential solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $4,590.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins. 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add?500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: JIRLES,PETER&SHERYL SOLARCITY CORPORATION Required Items and Reports(Conditions) 14225 SW 116TH TER 6132 NE 112TH AVE TIGARD,OR 97224 PORTLAND,OR 97220 PHONE: 503-504-0108 PHONE 503-894-6903 FAX: 866-445-7459 Total Fees: $321.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. A •• Oregon law requires you to follow the rules adopted by the Oregon Utility Notification ter. Those rules are set forth in OAR 952-0. -0010 through••R 95 10 .090. You may obtain a copy of the rules or direct questions to OUNC by calling 50 ' . :7 or 1:32.23 Iss -d By: ��L Permittee Signature: �11,/► J� .. Call 503.639.4175 by 7:00 a.m.for the next available Inspe on date. �_r • This permit card shall be kept in a conspicuous place on the job site until completion o th, t , Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential RECEIVED FOROFIRL t -I I IN i 1 City of Tigard Received /'/ City g Peril No' }/`1-610/0/SL ,� ' 13125 SW Hall Blvd.,Tigard.OR � 3 0 2014 nalers ? T + S�aC Phone: 503.718.2439 Fax: 503.5 8., �i��l� Other Perm° I I G A R l? Inspection Line: 3.63.4176 CITY OF TIGARD Uate Ready:y: p ` 7uru Supplemental See Pace l for Internet: www.ti rd-or. ov Notified/MNhod: U /y 1y Supplemental Information 3141,4 44: DIVISION hi it-i //`l6Z/ssrq- TYPE OF WORK REQUIRED DATA:I-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 21 Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the ('A'1'EG(IR1" OF ('ONS"1'RUCTION work indicated on this application. ® I-and 2-family dwelling ❑Commercial/industrial Valuation: 5 4590 ID Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: _ Job site address: 14225 SW 116TH TERRACE New dwelling area: square feet City/State/ZIP: TIGARD OR 97224 Garage/carponarea: square feet Suite/bldg./apt.no.: Project name: JIRLES RESIDENCE Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERC'IALI'SE CHECKLIST Subdivision: I.ot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. PV ROOF MOUNT Valuation: S Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name. SHERRY JIRLES Type of construction: Address: 14225 SW 116TH TERRACE Occupancy groups: City/State/ZIP: TIGARD OR 97224 Existing: Phone:(50`31 504 0108 I Fax:( ) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES Business name:SOLAR CITY (Please refer S MK*aja Contact name:MELISSA BENTLEY Structural plan review fee(or deposit): Trt FLS plan review fee(if applicable): Address:6132 NE 112 AVE City/State/ZIP:PORTLAND OR 97220 Total fees due upon application: Phone:(503)894 6903 f Fax::(1866)445-7459 Amount received: E-mail:ABENTLEY(ipSOLARCITY.COM PHOTOVOLTAIC'SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONT'RACT'OR roof-top mounted PhotoVoltaic Solar Panel System. Business name:SOLAR CITY Submit two(2)sets of roof plan with connection details ,e and fire department access,along with the 2010 Oregon Address:6132 NE 112 AVE Solar Installation Specialty Code checklist. City/State/ZIP:PORTLAND OR 97220 Permit Fee(includes plan review 5180.00 and administrative fees): Phone:(503)894-6903 I Fax:(1866)445-7459 State surcharge(12%of permit fee): 621.60 COI lie.: 180498 I Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. 7/29/14 I •Fee methodology set by To-County Building Industry Print name:A. MELISSA TLE Service Board. I:\BuildingPermits\BUP-RESPermitApp.doc 02/24/2011 4404613T(II/02/COM/WFB) , Electrical Permit A ce liCEIVE1 11>„ (,i i 1 1 ,1 1 i I 1 Si City of Tigard n 71I P«mitNo.: gTap/t(—rx�l3S� 13125 SW Hall Blvd.,Tigard,OR ; 3 0 2014 Plan Review Phone: 503.718.2439 Fax: 503.5W:1960 DatdB Other Permit: Inspection Line: 503.63975 CITY OF TIGARD Date ReadyBy: .I 0 See Pace 2 for Internet: www.tigsrd-or. 1. Notified/Method: Suppkwentallararwatba IdBIG DIVISION PLAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit j sets of plans w/items checked below): ❑Service or Ikeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OP CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. ® 1-and 2-family dwelling ❑CommerciaVindustrial Accessory building less for other a exceeds 14,000 n. ❑commercial-use agricultural ❑ rY $ amps far aB other irhatallNions. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 K VA or JOB BITE INFORMATION AND LOCATION ❑Addition y system. larger E".separately ","1-3". system. ❑Addition of new motor load of ❑"A""E""I-2""1-1" Job no.: 9722112 Job site address: 14225 SW 116TH TERRACE I00HPormore. occupancy. O Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP: TIGARD OR 97224 ❑Healthcare Ihcililies. O Supply voltage for more than ❑Hazardous locations. 600 volts nominal Suite/bldg./apt.no,: I Project name: J I RLES RESIDENCE ❑Service or feeder 600 amps or mare. FEE SCHEDULE Cross street/directions to job site: Deserted.. I Qty. I Fee. I Tout I • New residential single or multi-family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.IL or portion 33.92 1 Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.IL) - Limited energy.multi-family 75.00 2 PV ROOF MOUNT residential(with above sq.B) Renewable Energy See Pay 2 Services or feeders installation,alteration.and/or relocation ® PROPERTY OWNER 1 ❑ TTi:NANT 200 amps or less 100.70 2 Name: l 201 amps to 400 amps 133.56 2 SHERRY J I RL ES 401 amps to 600 amps 200.34 2 Address: .14225 SW 166TH TERRACE 601 amps to 1,000 amps 30104 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP: TIGARD OR 97224 Temporary services or feeders installation,alteration,and/or Phone:(503) 504 0108 I Fax:( ) relocation 200 amps or less 59.36 1 Owner installation:This installation is being made on property that 1 own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits-new,alteration,or ex_tension,per panel ® APPWCANT I is CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name:SOLAR CITY each branch circuit B.Fee for branch circuits without Contact name:MELISSA BENTLEY service or feeder fee,first 56.18 2 branch circuit Address:6132 NE 112"AVE Eachadd'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) City/State/ZIP:PORTLAND OR 97220 Each manufactured or modular 67.84 2 Phone:(503)894-6903 I Fax::(1866)445-7459 dwelling,service and/or feeder Reconnect only 67.84 2 E-mail:ABENTLEY®SOLARCITY.COM Pump or irrigation circk 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:SOLAR CITY Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 _ 2 Address:6132 NE 112TlI AVE Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr City/State/ZIP:PORTLAND OR 97220 Investigation(1 hr min) 66.25/hr Phone:(503)894-6903 Fax:(188)445-7459 Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 180498 I Electrical Lic.: C562 //1111 Suprv.Lic.: 52015 specifically listed(Si hr min) 90.00/hr EIACTRICAL PERMIT FE Suprv.Electrician signature,required: Subtotal: Print name: DEREK CROPP Date: 7/29/14 Plan review(25%of permit fee): t _ State surcharge(12%of permit fee): Authorized signature: rI TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: A. MELI ' i Date: 7/29/14 days after It has beta accepted as complete. • Number of inspections allowed per permit. 118uildingWomM IIELC_PeraaiApp_ELR ERE dew Ray 03/01/2013 440.4615T(11/03KOM/w[B r Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Fee for all residential systems combined........ $75.00 r>r ;ptw 1 Qtr. [ pee ( Thai {' Renewable electrical energy systems: Check Type of Work Involved: 5 kva rr less 1 100.70 100.70 2 5.OI to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: n Burglar AIanii - 2501 to 50 kva 30104 2 Garage Door Opener* 50.01 to 100 kva 552.26 2 I00 kva(fce in accordance with 552.36 2 ❑ Heating, Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systenis In excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva no additional charge 0 C 3 Each additional inspection over allowable in any of the above: Other: Each additional inspection is 66 251 hr charged at on hoally(1 hr min) Inspections for which no fee is 90 Ipr hr specifically listed t;i hr min) Fee for each commercial system ... $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fcc): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: Thi3 permit application spires if a pet•tall is not obtained within 180 nAudio and Stereo Systems days after it has been accepted as complete. • Number at inspections allowed per permit El Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ 1-IVAC ❑ Instrumentation H Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical n Nurse Calls n Outdoor Landscape Lighting* [1 Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations B.k1 n.lc in LC_l w,nilApp_LLIt_Em'.loc Rcv 115,212vI !PI City of Tigard RECEIVED I MI Building Division 13125 SW Hall Blvd,Tigard, OR 97223 JUL 3 0 2014 • Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 CITY OFTIGARD www.tigard-or.gov BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14225 SE 116TH TERRACE City: TIGARD Zip: 97224 Owner's Name: SHERRY JIRLES Date: 7/29/14 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:Bui lding/Forms/PhotoVoltaic-Checkl isidocx Is the construction material wood and does • Yes Type of If"Yes", qualifies for the construction qualify Construction 111 No the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. 0 No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ® If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for I I the 2010 Oregon Solar NO the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No to the roof framing or blocking the prescriptive path. directly? 2 I:Building/Fortes/PhotoVoltaic-Checklist.docx Is the gauge 26 or less? 1-1 Yes If"Yes", qualifies for ❑ No the prescriptive path. • 115 lbs for 60 inch spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes",qualifies for I fastener? Yes the prescriptive path. I No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members El No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: TRINA SOLAR Model Number: TSM-250PA05.18 Listing Agency: UL-1703 4 l:Bui I ding/Fonns/PhotoVoltaic-Checklist.docx ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING RE E ' I AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, - BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. JUL 3 0 2014 DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY CITYOFTIGARD (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING BUILDING DIVISION FSB Fire Set-Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL GND GROUND COMPLY WITH ART. 250.97, 250.92(8) CITY OF TIGARD HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER REVILwED FOR CODE COMPLIANCE I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC Approved: [ 1.4/ Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). OTC: 1 1 kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Pcrrnit#: J 446T-20(4- -e27(2-- LBW LOAD BEARING WALL UL LISTING. Address: )42_2,5- -6-0 / (c , — MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE (N) NEW UL-LISTED LOCATION PROVIDED BY THE Suite#: 1447- NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING ) Dates NTS NOT TO SCALE HARDWARE. Br ^` OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND P01 POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & SS STAINLESS STEEL 690.47. STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT -''-rt• Cn r 4. .#if -i• • ." .. _ �` ^ PV1 COVER SHEET r G • l . .'• " PV2 SITE PLAN ;W"Gaarde St -_'_ - - . - - SW Gaarde St�;"" PV3 STRUCTURAL VIEWS 7_ PV4 UPLIFT CALCULATIONS 4 - ` ' r " "`� V. ;� , i PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES :. -:„ .1`.-- �` = PV6 ELECTRICAL CALCULATIONS �, } ", f k.:. Cutsheets Attached OR # 180498 1. THIS SYSTEM IS GRID-INTERTIED VIA A , Y j t '� ` .'i' �� M, ,Q,g, R CGC1 UL-LISTED POWER-CONDITIONING INVERTER. i M„ f• ? _ • s,.. . \" ' • 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. •. 3. SOLAR MOUNTING FRAMES ARE TO BE ii .:4 .: . GROUNDED. ' ! ;� .� ,r 4. ALL WORK TO BE DONE TO THE 2010 OBC �. ç r- A I ,�' rti^ .1i -A".. , ` MODULE GROUNDING METHOD: ZEP SOLAR BASED ON THE 2009 IBC. • 7 f - Y -- -, . i,. i r_ ,�\, ! 4 4. 5. ALL ELECTRICAL WORK SHALL COMPLY WITH .. ,� ea • I.., A i b REV BY DATE COMMENTS AHJ: Tigard THE CURRENT NATIONAL ELECTRIC CODE AS ` • • • t REV A DATE COMMENTS AMENDED BY THE OREGON ELECTRICAL SPECIALTY • - Akt), ` ' ,i t - - ' �,1 _IM CODE. r '� : ►�' i:. =y r`! �i 4 -- �V ■,�1©-_ UTILITY: Portland General Electric • 1� t•' ®®® ` cip " an d O orf.State f on U.S. eolo is urve.. . re Oregon, c ®®® 9 � of 9 � � Y J B—9722112 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER' CONTAINED SHALL NOT BE USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist =\..;So�arC�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ;.''"' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14225 SW 116TH TERRACE 4.59 KW PV ARRAY ,, PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULEP TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV DAIS: 3055 9Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN T:(650)638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. INVERTER (503); AURORA PVI-3.6-OUTD-S-US-Z-A (503) 504-0108 COVER SHEET PV 1 7/28/2014 (688) soL-arn(765-2489) www.sdarcity.com • PITCH: 36 ARRAY PITCH:36 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 14 MATERIAL: Comp Shingle STORY: 2 Stories 225 SW 116th Terrace (E)DRIVEWAY ATTACHMENTS SHALL SE SPACED NO GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS LOCATED WITHIN 3 FEET OF A ROOF EDGE,HIP,EAVE OR RIDGE. OSISC 305.4.3(B) LEGEND \ I-, \/ 11 I r O (E) UTILITY METER & WARNING LABEL ® ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS �- 1 DC DISCONNECT & WARNING LABELS AC I-.H AC DISCONNECT & WARNING LABELS °Ladd Gited o ° DC JUNCTION/COMBINER BOX & LABELS • 0 DISTRIBUTION PANEL & LABELS ° ° Loiked Coated. a a 1. i etbac j LC LOAD CENTER & WARNING LABELS v 0 _ O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR =MI — CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED c.----1 '( ;I INTERIOR EQUIPMENT IS DASHED L_J A N TOTAL ARRAY AREA (SF): 324 SITE PLAN TOTAL ROOF AREA (SF): 2494 Scale: 3/32" = 1' w `+ E TOTAL ARRAY AREA IS a 12.98 O 1' 10' 21' PERCENT OF TOTAL ROOF AREA 1'-■mmmil S J B-9 7 2 2112 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER ts::zSolarCity.CONTAINED SHALL NOT BE USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist .,BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WNOLE OR IN Comp Mount Type C 14225 SW 116TH TERRACE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A (503) 504-0108 SITE PLAN PV 2 7/28/2014 (888)-SOL-aTY(765-2489) www.solacity.com I! (E) 2x4 PV MODULE / 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE PRE-MANUFACTURED TRUSS ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT (1101 STRUCTURE MEETS THE ZEP ARRAY SKIRT (6) HOLE. PRESCRIPTIVE REQUIREMENTS -- -' SEAL PILOT HOLE WITH OF THE OSISC SECTION 305.4 (4) (2) POLYURETHANE SEALANT. ZEP COMP MOUNT C A11713111WAITAIIIIIIII0 NINININP'4010-11-6-114 --- CO / ZEP FLASHING C `���a� (`) INSERT FLASHING. �. �. r�� V— ��jc'L'a ��� (E) COMP. SHINGLE vs; ■:■ (4) PLACE MOUNT. 1'�; 5'-3° 5'-9" 5'-10" (E) ROOF DECKING (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. M (E) LBW STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH_ SIDE VIEW OF MP1 NTS WITH SEALING WASHER (6) BOLT & WASHERS. A (2-1/2" EMBED, MIN) MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER STANDOFF LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 16" 0 Scale: 1 1/2" = 1' TOP CHORD 2x6 @ 24"OC ROOF AZI 180 PITCH 36 STORIES:2 ARRAY AZI 180 PITCH 36 ROT CHORD 2x4©24"OC Comp Shingle J B-9722112 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION USED FOR THE JOB NUMBER: ‘.,,So�arCity CONTAINED SHALL NOT FO USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14225 SW 116TH TERRACE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULEP TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearvlew Woy THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR TSM-255PA05.18 Soo Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME: SHEET: REV DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A (503) 504-0108 STRUCTURAL VIEWS PV 3 7/28/2014 (888)-sa-CITY(765-2489) www.solorcity.com UPLIFT CALCULATIONS 07.28.2014 SolaiCity SleekMount'M PV System Version#37.7 Structural Design Software Project Information &Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'" Comp Roof Comp Roof Layers of Comp Roofing 1 Roof Slope 36° Rafter Spacing a _ 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 317 sf PV Module Width 39" PV Module Length `iu` 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf 1 ASCE Table 7-1 Surrounding Roof Snow 1009k 25.0 psf 'ASCE Eq: 7.4-1 Roof Snow Over PV Modules 100% 25.0 psi 'ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 ' Wind Design Method Partially/Fully Endosed Method Basic Wind Speed V 95 mph ' Fig.6-1 Exposure Category C ' Section 6.5.6.3 Roof Style Gable/Hip Roof 'Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft agialsonamook Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.6 psi Ext.Pressure Coeffident(Up) GCp(Up) -0.95 Rg.6-11B/C/D-14A1B Ext.Pressure Coeffident(Down) GCp(Down) 0.88 Fig.6-118/C/D-I4A/B Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure Up p(up) -17.7 psi Wind Pressure Down p(down) 16.3 psi Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spadng Landscape 72" 39" Max Allowable Cantilever Landscape RISSIONAMINI. 24" NA Standoff Configuration Landscape Staggered __ Max Standoff Tributary Area Tribl11h 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual MUM -316 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capadty DCR 63.2% Max Allowable Standoff Sparing Portrait 48" 65' Max Allowable Cantilever Portrait 16" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Tub 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -351 lbs Uplift Capacity of Standoff T-allow 500 lbs • Standoff Demand/Capacity DCR 70.1% CONFIDENTIAL J B THE INFORMATION HERON -9722112 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: EIN JOB NUMBER: \‘,4 CONTAINED SHALL NOT BE USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist : ;S��arC�ty , BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM 14225 SW 116TH TERRACE 4.59 KW PV ARRAY �"•1:' 1 y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS MoouLE� TI G A R D, OR 97224 NM ORGANIZATION, EXCEPT IN CONNECTION W 3055 Clearvlew Way THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NVEIt7ER: # PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. (503) 504-0108 PV 4 7/28/2014 :(s5o)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A UPLIFT CALCULATIONS ( )—SOL—CITY(765-2489)WWW.eoiorcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded OR # 180498 INV 1 —(1)POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A LABEL: A — 1(8)TRINA SOLAR 1 TSM-255PA05.18 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23129129 FCI Inverter; Zigbee 3600W, 240V, 96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 373 Vpmax: 30.5 . INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E 200A MAIN SERVICE PANEL E5 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND 1 . (E) WRING COOPER � 200A/2P Meter Socket (3 POWER—ONE DC, DO NOT ADJUST MIN.ACTIVATION V TAGE AURORA PVI 3.6—OUTD—S—US—Z A Dc- I String(s)Of 9 On MP1 (1 •� (E) LOADS A I 290V I r ___ EGC J • �. n �4- Lz DD. I • I • • I 1 II 11 N DG I 2 DO NOT ADJUST MIN.ACTIVATION V TAGE 20A/2P GND EGCI �_ DC*I�� DC N 1� l• A " GEC - T� 1.---- `� DC- I pp 1 SMrg(5)Of 9 On MP1 • B I Ll® EGC -----f-- - -r EGC VL. J V (1)Conduit Kit; 1' EMT N ki EGCIGEC o- Z-CD CD — Z GEC r Y TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I I I I I I I I I I I I — — Voc* = MAX VOC AT MIN TEMP POI_(1)CUTLER-HAMM R j BR220 PV BACKFEED BREAKER A —(1)COOPER B Line Meter Socket 011 /� D Breaker, 20A/2P, 2 Spaces Meter Socket; 125A, 4-14AWG, Ring Type H -(2)Ground Rod; 5/8' x 8', Copper -(1)AW CAP; B-Line Meter Socket Accessory -(1)Milbank i CL200D /Itron CIS Solid-State Single-Phase Meter; Digitol O (1)AWG/10, TH•N-2, Black (2)AWG /10, PV WIRE, Black Voc* =380.56 VDC Isc =8.92 ADC (1)AWG 110, THWN-2, Red 1 1 AWG S Bare copper EGC Vm =274.5 VDC Imp=8.36 ADC (1)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)Conduit( ) p p Kit;Stronded de EMT -(1)AWG/8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4'EMT O (2)AWG /10, PV HARE, Black Voc* =380.56 VDC Isc =8.92 ADC �(1)AWG /6, Stranded Bare Copper EGC Vmp =274.5 VDC Imp=8.36 ADC (1)Conduit Kit; 3/4' EMT • J B-9722112 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: \\`!t � CONTAINED SHALL NOT BE USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist �;,,SoIarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��•• l.�/ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14225 SW 116TH TERRACE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULEP TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH , ardew ay W THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV DATE: S 3055 an Mateo CleCle Ce say2 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) 638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A (503) 504-0108 THREE LINE DIAGRAM PV 5 7/28/2014 (888)-SOL-aTY(765-2489) •ww.solarcity.com • ELECTRICAL CALCULATIONS Module: 18 TRINA SOLAR#TSM-255 ZEP 232.2 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 6_0.8 Inverter 1: 1 Power-One PVI-3.6-S AFCI 96.0% 3,840 4,012 Vdrop= (Imp) • (2'Length)•(Resistance) / (Vmp) Module: f Imp(A) Max. Length(ft) Wire Inverter 2: String: I 8.36 30 C AWG 10 at Max Me Hi: 80 deg F Module: Vdrop= (8.36 A ' 60 ft '0.00124 Ohms) / 231 V= 0.27% . Inverter 3: Branch: 8.36 I 80 1 C AWG 10 at Max Ave Hi: 80 deg F Module: Vdrop= (8.36 A ' 160 ft •0.00124 Ohms) / 231 V= 0.72% Inverter 4: Total voltage drop in DC conductors= 0.99% Inverter: I 16.00 I 80 I E AWG 06 at 240V Total: 18 modules Total Inv Pwr 3,840 4,012 PTC Vdrop= (16.00 A • 160 ft '0.00049 Ohms) / 240 V 0.52% Photovoltaic Module Electrical Specifications: Total STC 4,590 Combined 16.00 I 0 I E AWG 06 at 240V Voc= 37.7 V deg F deg C Vdrop= (16.00 A ' 0 ft "0.00049 Ohms) I 240 V 0.00% Vmp= 30.5 V Record Low Temp: 8 -13.3333333 Total voltage drop in AC conductors = 0.52% lsc= 8.92 A Max Average Hi Temp: 80 26.66666667 Total voltage drop in AC and DC conductors = 1.51% Imp= 8.36 A Record Hi Temp: 106 41 Tvoc= -0.12064 V/deg C Power-One Strings: Individual MPPT Tisc= 4.1924 mA/deg C I String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1-way wire length: 80 It Power-One PVI-3.6-S AFCI 1 strings per branch 1 1 strings per branch 2 9 TRINA SOLAR#TSM-255 ZEP Inverter Min Vdc Input: 120 Vdc 9 modules per series string 9 modules per series string Voc= 339.3 V Min Vmp at Max Temp: 214 Vdc Voc= 339.3 V 339.3 V Vmp= 274.5 V Max Voc at Min Temp: 381 Vdc Vmp= 274.5 V 274.5 V Isc= 8.92 A Inverter Max Vdc Input: 600 Vdc Isc= 8.92 A 8.92 A Imp= 8.36 A Max String Size: 14 Imp= 8.36 A 8.36 A Icont= 11.15 A Art 690.8(A)(1) 1-way wire length: 30 ft lcont= 11.15 A 11,15 A Art 690.8(A)(1) 1.a Conductor:C AWG 10 PV Wire 2.a Conductor 1:C AWG 10 Conductor 2:C AWG 10 Conductor 1: Conductor 2: Icont' 1.25= (Amps) 13.94 Icont'1.25= (Amps) 13.94 13.94 30 deg C ampacity= 40 30 deg C ampacity= 40 40 I 1.b Icont= (Amps) 11.15 2.b lcont=(Amps) 11.15 11.15 Start ampacity 40 Start ampacity 40 40 Temperature derate(%=F) 0.76 Temp.derate(%=F) 0.71 0.71 Conduit fill derate(%=#) 0.7 Cndt.fill derate(%=#) 0.8 0.8 Derated ampacity 21.28 I Derated ampacity 22.72_ 22.72 Term 1 Term 2 1.c Icont'1.25= (Amps) 13.94 Temp table 90degC 90degC Ampacity 40 2.c Icont'1.25=(Amps) 13.94 13.94 I Ampacity 40 40 I 1.d Icont'1.25= (Amps) 13.94 2.d EGG C AWG 10 C AWG 10 Art. 250.122 OCP size= 15 OCP size= 15 15 Inverter Type A Output Combined Inverter Output Power-One PVI-3.6-S AFCI 1-way wire length: 80 11 Service Voltage= 240 Volts Icont= 16.00 A Art 690.8(A)(1) Total Inverter Power= 3,840 Nameplate Watts 1-way wire length: 0 It 3.a Icont'1.25= (Amps) 20.00 A Art 690.8(B)(1) Icon!=#of inverters•max inverter current Art 690.8(A)(1) OCP size= 20 A Art.240.6(A) Icont= (Amps) 16.00 3.b Conductor E AWG 06 THWN-2 at 90 deg C: Table 310.15(B)(16) 4.a Icont•1.25= (Amps) 20.00 A Art 690.8(B)(1) Icont'1.25= (Amps) 20.00 OCP size= 20 A Art. 240.6(A) 30 deg C ampacity= 75 _ I 4.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.15(B)(16) 3.c Icont= (Amps) 16.00 Icont'1.25= (Amps) 20.00 Start ampacity 75 30 deg C ampacity= 75 I Temperature derate(%=F) 0.91 4.c Icont= (Amps) 16.00 Conduit fill derate(%=#) 1 Start ampacity 75 Derated ampacity 68.25 I Temp.derate(%=F) 0.91 3.d Icont'1.25=(Amps) 20.00 Cndt.fill derate(%=#) 1 Ampacity 65 1 Derated ampacity 68.25 I 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3).250.166(B) 4.d Icont*1.25= (Amps) 20.00 Ampacity 65 I J B-9722112 0 0 PREMISE OWNER. DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: +� !}CONTAINED SHALL NOT BE USED FOR THE JIRLES, SHERRY JIRLES RESIDENCE Brady Gilchrist SoIarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: -�'�"' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14225 SW 116TH TERRACE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULE P �' TI G A R D, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clear-view Way THE SALE AND USE OF THE RESPECTIVE 18 #TRINA SOLAR # TSM-255PA05.18 San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DATE: T;(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER' (503) 504-0108 PV 6 7/28/2014 (888)-SOL-CITY(765-2489) www.solarcity.com POWER-ONE_# AURORA PVI-3.6-OUTD-S-US-Z-A ELECTRICAL CALCULATIONS Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (POI) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _v NEC 690.54 SECOND SOURCE Is NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: • PHOTOVOLTAIC DC (DC) (INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- A (DC) (INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER-_V NEC 690.53 POINT VOLTAGE(Vmp) Label Location: MAXIMUM SYSTEM V VOLTAGE(Voc) WARNING (AC) (POI) SHORT-CIRCUIT A Per Code: CURRENT(Ise) ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (POI) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.B.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A PHOTOVOLTAIC AC (AC) (P01) OPERATING CURRENT (AC): AC Disconnect MAXIMUM AC v (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB):CB : Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (P01) (LC): Load Center Per Code: (M): Utility Meter PHOTOVOLTAIC SYSTEM NEC 690.64.B.4 CIRCUIT IS BACKFED (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `%41f4j r 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set ����� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ! Sola rC ity (888)-50L-CiTY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 0 S ZS Comp Edge Zone Calculations 1 of 4 0 ZS Comp Edge Zone Calculations 2 of 4 Zep Sola r 5/28/13 Zep So lar 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing- calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads design load landscape= 9.62 17.32 17.32 psf Uplift= 656 lbs Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs AO.r.01.1 note:use 10 psf minimum �, ,r". 6•a';,,�- Snow Calculations Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing 13 OREGON r lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 degrees. Allowable Uplift Load FRr >o. � uplift spacing= Orr Ro module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 Design Snow Load 29.11 25.98 psf p=ghGCN Kd V2 I (snow load spread over the length of the rafter) qh=0.00256 Kz K=t Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kit= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf lorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 lscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape down force spacing = 39"x132.46 s x 144 [t2 = 130" ortrait effective area= 21.7 ft2 p f f Plandscape= -30.79 psf qh= 19.25 psf Pportralt= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ft2 = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = x 144 39"x 29.05 psf ft2 =83" 656 lbs in • portrait uplift spacing = 65"x 27.12 psf x 144 ft2 = 54" 0 ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 ZepSolar 5/28/13 ZepSolar 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+ 120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing =-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing =-1.4545 x 32.46 psf+120.7273 =73" Ps=Cs Pf Roof Pitch= 31 45 degrees pf=0.7CeC5IPg Ce= 0.9 Cs= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing= -1.7917 x 32.46 psf+118.58= 60" = 1.0 ps= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) Lateral 30° 27° 30° 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing= 39"x 14.49 psf x 144 f't2 =74" 2921bs in portrait lateral spacing = 65"x 14.49 psf x 144 Ft2 =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees portrait lateral spacing= 65"x 13.50 psf x 144 Ft2 =48" SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed _„. '` Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and •Interlock and grounding devices in system UL • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps,combined with the addition •Interlock and Ground Zep ETL listed to UL 1703 -- • Seal pilot hole with roofing sealant of array trim and a lower profile all contribute P _ s. to a more visually appealing system.SleekMount as"Grounding and Bonding System" ti, • Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as \ layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs,effectively eliminating the .- need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance • Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this I \\_____ with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions • Secure Leveling Foot to the Comp Mount using machine Screw • Place module 4Z Z.S. ifil 411 Components \�� - • 5/16"Machine Screw <( %Nil • Leveling Foot • Lag Screw e • Comp Mount • - • Comp Mount Flashing •' dit <0 ',ell �pMP� t 4 SolarCity, January 2013 : 01) 0 LISTED SolarCitym January 2013 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE ISM-PA05.18 ELECTRICAL DATA SIC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 • 941mm Peak Power Watts-Pwr(Wp) 240 245 250 255 260 -S . •0' Power Output Tolerance-PMAx(%) 01+3 0/+3 0/+3 0/+3 0/+3 AM,. m Maximum Power Voltage-VMr,(V) 29.7 30.2 30.3 30.5 30.7 sox o - Maximum Power Current-IwT(A) 8.10 8.13 8.27 8.36 8.47 Ts _ PA405 .18Talr Mn�� Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 `.amu Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency ro,(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE 3 SIC:Irradiance 1000 W/m'.Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction Cell Temperature tur 25°C,according to EN 60904-1. E ,o E o O S 3 ELECTRICAL DATA NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Px,Ax(Wp) 174 178 181 184 188 (V. Maximum Power Voltage-VMr(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE 60.3C UCIN4 HOU Maximum Power Current-1. (A) 6.55 6.64 6.70 6.77 6.86 A A WITH TRINAMOUNT FRAME //�10P°1NH01 Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 't / Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 1 812mm I 180 I NOCI.Iradiance at 800 w/m'.Ambient Temperature 20°C.Wind Speed I m/s. 240-260W Bock view POWER OUTPUT RANGE DATA Our most versitile product 11 I • Compatible with all major BOS components and system -� Solar cells Multicrystalline 156.156 mm(6 inches) designs Cell orientation 60 cells(6 x 10) 15.9 0 v o Module dimensions 1650 x 992.40 mm(64.95 x 39.05 x 1.57 inches) Weight 18.6 kg(41.0 Ibs) MAXIMUM EFFICIENCY 1 Glass High transparency solar glass 3.2 mm(0.13 inches) Backsheet White One of the industry's most trusted modules C Frame Black Anodized Aluminium Alloy with Trinamount Groove • Over 2 GW sold across all major global markets 0 �'3% • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 C-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10.. 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9m ••' Bm Connector Original MC4 7m 800w/m° Highly reliable due to stringent quality control i 5m \M As a leading global manufacturer • Over 30 in-house tests(UV,TC,HF,and many more) V 4.0. :: `; TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic 011- • In-house testing goes well beyong certification requirements '°° ,/m \I Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close 2m V Temperature(NOCT) cooperation with our partners Mil Maximum System 1000V DC(IEC)/ 0.e Temperature Coefficient of P.ux -0.43%/°C Voltage 600V DC(UL) is critical to success. With local o.m to.° 20.. 30.0 40.. presence around the globe,Trina is Vdtope(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Isc 0.047%/°C to each customer in each market Certified to withstand challenging environmental and supplement our innovative, reliable products with the backing conditions of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please reler to product warranty for details) and other partners as the ■ backbone of our shared success in CERTIFICATION r� driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY (� -. PACKAGING CONFIGURATION c 10 Year Product Warranty• 25 Year Linear Power Warranty A. \ w „„,•u C spUS Modules per box:24 pieces Trina Solar Limited www.trinasolar.com `u 100% ISO t o (E Os N'emu Modules per 40'container:672 pieces f aAddition al vat ., MEI Nt • d 90% °e ft Trina Solar- ne Y 0 s l! I� • o _ ar Warrant CAUTION:na Solar SAFETY iimited AND rights INSTALLATION ved INSTRUCTIONS n hTHda PRODUCT.1 ore subject to ���4r F Tr�nasolar 809 Tr�nasolar change without notice. Smart Energy Together years s 0 s 20 25 Smart Energy Together 'h ��'CO Trina Solar • ri • power ONO Renewable Energy Solutions S TECHNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Q .-...... . . . 01: Nominal Output Power W 3000 3600 3300 3800 4200 C Maximum Output Power W 3000 3300' 3300' 3600 4000' 4000' 3300 3800 4200' 3000 4600' 4600' Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 208 240 277 1( < Input Side(DC) PVI-J.O-T L Number of Independent MPPT Channels 2 2 2 2 Maximum Usable Power for Each Channel W 2000 3000 3000 3000 PVI-3.6-1L Absolute Maximum Voltage(Vmax) V 600 200 la Start-Up Voltage(Vstart) V (adj.124350) j^( Full Power MPPT Voltage Range V 160-530 120-530 n D 7xVzta > 140-530 114530 P VI-3.V-T L Operating MPPT Voltage Range V -580( =90V) Maximum Current Ildcmax)for both MPPT in Parallel A 20 32 32 32 Maximum Usable Current per Channel A 10 16 16 16 P1/I-4.2-TL Maximum Short Circuit Current Limit per Channel A 12.5 20.0 20.0 20.0 Number of Wire Landing Terminals Per Channel 2 pairs Array Wiring Termination Terminal block,Pressure Clamp,AWGIO-AWG4 output Side(AC) GENERAL S P E C I F I C AT I O N S .4 Grid Connection Type 10/2W Split- 10/2W 10/2W Split 10/2W 10/2W SpIA- 10/2W 10/2W Split- 10/2W 0/3W 0/3W 0/3W 0/3W AdjustableValtage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 g Grid Frequency Hz 60 Adjustable Grid Frequency Range Hz 57-60.5 O Maximum Current(lacmaxl Amos 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16,0 16.0 20.0 20.0 20.0 Power Factor >0995 The most common residential inverter is the ideal size for an average Total Harmonic Distortion At Rated Power % 2 sized family home. This family of single-phase string inverter Grid Wiring Termination Type Tertttklalbbck Pressure Clamp AWG10-AWG4 < Protection Devices complements the typical number of rooftop solar panels,allowing Input , .. Reverse Polarity Protection Yes home owners to get the most efficient energy harvesting for the /"/" „////" .-?,//eee Over-Voltage Protection Type Varistor,2 for each channel size of the property.This rugged outdoor inverter has been designed - - - -- PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental output Anti-ISlanding Protection Meets UL 1741/IEE1547 requirements conditions. External AC OCPD Rating Am, 20 20 15 25 20 20 20 20 20 25 25 25 I Over-Voltage Protection Type Varistor,2(I.,-I,/1.-G) Efficiency One of the key benefits of the Uno family of single-phase inverters Maximum Efficiency % 96.9 97 97 97 is the dual input section to process two strings with independent CEC Efficiency % 96 MPPT especially useful for rooftop installations with two different Night im Performance Cons m Consumption p y p ) Night Time Consumption Ww, <06 • orientations(ie East and West).The high speed MPPT offers real-time a Stand By Consumption Www, <B • Communication power tracking and improved energy harvesting. User-Interface 16 characters x 2 lines LCD display Remote Monitoring(1 090485 incl.) AURORA-UNIVERSAL(opt.) The transformerless operation gives the highest efficiency of up to }" Wired Local Monitoring I1xRS485 incl.) PVI-USB-RS485 232(opt.),PVI-DESKTOP(opt.) Wireless Local Monitoring PVI"DESKTOP(opt.)with PVI-RADIOMODULE(opt.) 97.0%. The wide input voltage range makes the inverter suitable to • Environmental low power installations with reduced string size. Ambient Air Operating Temperature Range "F('C) -13 to+140(-25 to+60)with derating above 122(50) i,. Ambient Air Storage Temperature Range "F 1'C) -40 to 1761-4010+80) Relative Humidity %RH 0.100 condensing Acoustic Noise Emission Level db(A)@1m <50 Maximum Operating Altitude without Derating ft(m) 6560(2000) F C a•u r C^ Mechanical Specifications Enclosure rating NEMA 40 VS .1.11111111111= Cooling Natural Convection Dimensions(H x W x DI in(mm) 33.8 x 12.8 08.7(859 x 325 x 222) • Each inverter is set on specific grid codes which can be selected in the field Weight >47.3(21.3) lb(kg) • Single phase output Shipping Weight lb(kg) <60(270) • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented Mounting System Wall bracket Trade size KOs:(tea x 1/2)and in different directions conduit connections' (tea x 1-1/4",3 places side,front,rear) • Wide in ut range Side-12)plugged 3/4-openings,(2)Concentric EKOs 3/4;1" I P 9 Back:(4)Concentric EKOs 3/4",1" • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting DC Switch Rating-(PerContact) AN 25/600 • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance Safety Isolation Level Transformerless(Floating Array) across the entire input voltage and output power range Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01,UL1998 UL1699B,FCC Part 15 Class B • Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions Safety Approval ,CSA-, Warranty • Integrated DC disconnect switch in compliance with international Standards(-S Version) Standard Warranty years 10 • RS-485 communication interface(for connection to laptop or datalogger) Extended Warranty years 15620 Available Models • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Swtich and Wiring Box PVIa9-OUTD-US PVI-3.6-OUTDUS PVI-3.8-OIITDU5 PVI-42-OUTD-US • Integrated Arc Fault Detection and Interruption(-A Version) Standard-With DC Switch and Wiring Box PVI-3.0-OUTD-SUS PVI-3.6-0UT0-S-US PVI-3.8-OUTD-s-U5 PVI-42-OUTD-S-US With DC Switch,Wiring box and Arc Fault Detector PVI-3.0-OUTD-SUS-A PVI-3.6-0010-S-US-A PVI-3.8-OI11D-S-US-A P1/I-4.2-OUTD-5-US-A and Interrupter 'All data is subject to change without notice AURORA UNO 1 - 'Capability enabled 0 nominal AC voltage and with sufficient DC power available AURORA UNO 3 'When equipped with optional DC switch and Wiring Hoe Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14225 SW 116TH TER, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - No C of O MST2014-00125 Jeff Grove Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14225 SW 116TH TER, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2014-00125 Jeff Grove Violation Summary: Inspector Contractor