Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT • COMMUNITY DEVELOPMENT Permit#: MEC2014-00428 Ti G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/12/2014 Parcel: 1 S 135BA00102 Jurisdiction: Tigard Site address: 10114 SW WASHINGTON SQUARE RD Project: Pieology Subdivision: OAKBURG Lot: 9 Project Description: Replace(1)RTU and(1)split system,like for like. Contractor: ARROW MECHANICAL Owner: PPR SQUARE TOO LLC 10330 SW TUALATIN RD PO BOX 847 TUALATIN, OR 97062 CARLSBAD,CA 92018 PHONE: 503-692-1565 PHONE: FAX: 503-691-1879 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 08/12/2014 $525.51 Class of Work: ALT Type of Const: Plan Review 08/12/2014 $131.38 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 08/12/2014 $63.06 Stories: Project Valuation: $17,000.00 Fuel Air Handlers Fuel Types: Units<10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $719.95 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Noti - -nter. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or di - questions to 0 C by calling 503.232.1987 or 1.800.332.2344. ued By: _ Permittee Signature:_ ; Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • . Mechanical Permit Ai ! • ' U i '''IVEP FOR OFFICE SE ON1,1' 1 City of Tigard Received ,,,• i f, 0....J.P) Pemait No.: 13125 SW Hall Blvd_ gard . • T ,OR 97223 i ' I Phone: 503.718.2439 Fax: 503.598.190 11111‘ Date/By: , I, Y Plan Review Date/By. Other Pam& Po 0( _60 I-7• Inspection Line: 503.639.4175 AUG 1 2 2014 TIGARD Date Ready/By: furis: 0 See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OFTIGARD ittAilti**IltligiNirkagT310110:070NS Ilig4".0.10 *0147;.***. tigtri Mechanical permit fees*are based on the value°film work- - 0 New construction $Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit Value:Si 17, 47.23L., - ID 1-and 2-family dwelling XCommercial/industrial 0 Accessory building For special information sae checklist 0 Multi-family 0 Master builder 0 Other: Description I Qty. I Ea. I Total 40111:1;..'1,0trt4t4,10,1444000:4164404-010ik'a'..VL::::21,:r.. .-A:. Jill Z' Air conditioning 46.75 Job site address: / )//1/_6./..4.) 1,0,167,i .., ,6 . , _..v Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: 77,G.A 12,0, E.,a 7 7.-7--3 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 _. Suite/bldg./apt.no.: 1 Project name: /0/" L.4,-.h7 (.../ Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision: I Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 Gas fireplace/insert 3339 * N:N:ta"Trkuit.ir::raeb-Mriftft#EWIO...;,,,,,,,;' Iry„,,,..43,,,,,,,,,,,4-;?:::1::::it:',..:'''-P4V1:=',':;-"f41,5':::';:Mfr%': Flue vent for water heater or gas . • PA_Pi__At.- C, ) r4.-/57,A./ On-, fireplace 23.32 Log lighter(gas) 23.32 6) 6-Pt 1-1-- 6 ei A 7- --1 Wood/pellet stove 33.39 Z.--// -f A- 1/e. ,.--; Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 _ Vfklfe:V,,Ji,• . 4;,./s4:-4*-01*.4--„ ,-.litealltireraliVWfat*:';-,4,;-..,,..A,.,,,.;::'1,7247''''',.:'4P--4*'"W Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 geiggivetcowiw 1:4:,--0•177;11001o :447-704.0to, go; °ther: 23.32 Fuel piping: Business name: kt 6--et•1,4 du;CI __frit,',e...., $14.15 for first four,$4.03 for each additional Contact name:/2.6v,/Ai ,e)/2 ej.f.s2‘-i e t i s./z4 Furnace,etc. • Gas heat pump Address: /0.3 3,.D rS ,_( 724 A z.-A-`7141/ al- Wall/suspended/unit heater City/State/ZIP: r7?„„...4-4 4-1--;;‘,..„, z> tf.)02ei/„....2 Water heater Phone:e) ) _ j7 I Fax::52:&)40,9 i, /63-2, Fireplace Range E-jrnail re912-‘ .401.4....) 4..1‘c.Fe ke--ackr7-1 .4 ebo, Barbecue ,WII''YgYe-VNP:PAW::tg''eiei'AWA:aPvll*,Ztl"f". .;VO4:.%*V:fr/cnie,'AW".V:,Mt:/ jEl;WO:- -,lY, Clothes dryer(gas) Other: Business name: itf:ilizi.2_02.4 j 4_14-zse.,A.Li-)e 4 4 axi7,.. zi--,...,, Impoggis*oorow:::::vgiw~404-mos.", Address: i.0 a D c..54„.j /Z4,4 4,A 7-2 A j /&)- Subtotal 50,5" 5 I t City/State/ZIP: -77,,,„7,_„4-7,A.,. ne 43'7 e le,2 Minimum permit fee($90.00) .------ Plan review(25%of permit fee) _13 1.4 Phone:53)40.(3 2 - /SZ,V Fa/6-1)3)( ,q/- ig? 9 State surcharge(12%of permit fee) 65, CCB lie.: S---/ e",..5 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 .-- • -- .../- , 9 -----)-9 . days after it has been accepted as complete. Authorized signs te: .. • Fee methodology set by Tri-County Building Industry Service Board Fs Print name: ,/, '" ,-, g,2 ,.._is 7_44/gia Date: 46.9-g-/41 1:\Buildi*Permits\MEC_PennitApp_040113.doc 440-4617T(11/07JCOMANE13) f • RECEIVED 0 TRANE Model AUG 12 2014 Nomencla 'IG%RD BUILDING DIVISION 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 ITWA3036A 3 00 0A A Air Handler AMSA 836 M31 - AA Outdoor Units T77i-1-;I ■ I7 TI* if i T TT Brand -- --- r Refrigerant Type T=Better 4-H-410A G=Good Product Type TRANE - A=Air Handler Product Type Convertabllity- W-Split Heal Pump M=Multi-poise 4-way T Spit Cooling =Upflow Front Return,3-way - T=3-way Product Family Product Tier Z-Leadership 2=Good.Entry Level Feature Set X=Premien 4=Better,Retail Replacement Mid Efly. R=Replacement/Retail 5=Better,Entry Level High Elf y.,Multi-Speed M or B=Basic 7=Best,Retail Replacement High Effy., A=Light Commercial Variable-Speed Family SEER 8=Best,Retail Ultimate High Efty, 0=20 3=13 6=16 Variable-Speed 1=11 4=14 8=18 Major Design Change----2=12 5=15 9=19 No Descriptor Split System Connections 1-6 Tons 0=Air Handler/Coil 0=Brazed Size(Footprint)- -- -Nominal Capacity in 0008 of BTUs A=17.5 x 21.5 8=21.0 x 21.5 Major Design Modifications C=23.5 x 21.5 Power Supply Cooling Sire:Air Handler or Coil 1=200-23071/60 or 208-230/1/60 0-9=AH Coil-1000 BTU's(18,24,30,36,42,48,60) 3=200.23043/60 Airflow Type&Capability 4=460"3/60 S=Low EEff ly PSC,1.5-nom.Tonnage(chiffon) Secondary Function M=Mid Effy Multi-Speed,1-5-nom.Tonnage(cfnVton) H=High Effy Multi-Speed,1-5-nom.Tonnage(cfmlon) Mina Design Modifications V=High Effy Variable.1-5-nom.Tonnage(cfnVlon) Unit Parts Identifier Power Supply 1=208-230/1/60 System Control Type S=Standard-24 VAC C=CLII 13.8 VDC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Minor Design Change- Gas Furnaces T u 1 0 8 0 A 9 H3 1 A Unit Parts Identifier-- -_-- • A I i7 T Iii Heat Pump/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Furnace C/Honzaton TU=UpflowMonzontal Cooling Coils j t A I iiiil- TD=Downflow/Honzonfal Type E=80%Induced Draft Standard Refrigerant Type---- D=80%Induced Draft Premium 4=R-410A C- 90%Condensing Standard X=90%Condensing Premium Series H=95%Condensing Premium T=Premium(Heat poop a Canertihe Cailj C=Standard(Caoig 0rdy) Number of Heating Stages -- Coll Design 1 =Single Stage X=Direct Expansion Evaporator Coil 2=Two Stage M=M dtiatitg Coll Feature C=Cased A Coil Cabinet Width-- -- - - - A=Uncased A Coil A=14.5'Cabinet Width F=Cased Horizontal Flat Coil B-17.5'Cabinet Width C=21.0"Cabinet Width Coil Width(Cased/Uncased) --- 0=24.5'Cabinet Width A=14.5'/13.3" B=17.5'/16.3' Heating Input in 1000's(BTUH) — C=21.0'/19.8' 080-80,000 BTUH D=24.5'/23.3' H=1as. Major Design Change Refrigerant Line Coupling - Voltage 0=Brazed 9=115 Volts/60 Hertz/Natural Gas A=115 Volts/50 Hertz/Natural Gas Nominal Capacity in 1000's(BTUH) C=115 Volts/Natural Gas with Communicating System Control Major Design Change F=115 Volts/Natural Gas with Integrated Electronic Fite* D=115 Volts/Natural Gas with Communicating System Control and Efficiency Integrated Electronic Fifer C=Standard Atr Capacity for Cooling S=Hi Efficiency(derived from 10 SEER products) Standard PSC Variable Speed High Efficiency Refrigerant Control 24=2Tons V3=3Tons H3=3Tons 3=TXV-Non-Bleed 36=3Tons V4=4Tons H4=4Tons Coil 42=35 Tons V5=5 Tons H5=5 Tons Circuitry 45=4Tons H=Heat Pump 48=4 Tons C=Cooling 54=5Tons 80=5 Tons Airflow Configurallon-- 72=8 Tons A=Upflow Only U=Upflow/Downflow 1=Single Speed Speeds C=Horizontal Only-Upfiow,Dowrdlow,Left or Right Airflow 2=Two Speed V=Variatke Speed Minor Design Change------ ------- -- - Minor Design Change- - _ -- Service Digit-Not Orderable-- ----- ----------- Service Digit-Not Orderable - - - - -- 22-1792-09 7 TRANE. General Data Product Specifications Model No.C!> 4TWA3060B3000A 4TWA3060B4000A Electrical Data V/Ph/Hz'z` 200/230/3/60 460/3/60 Min Cir Ampacity 20 10 Max Fuse Size(Amps) 35 15 Compressor SCROLL SCROLL RL Amps-LR Amps 15.6- 110 7.8-52 Outdoor Fan FL Amps 0.86 0.6 Fan HP 1/5 1/5 Fan Dia(inches) 27.6 27.6 Coil Spine FinTM Spine FinTM Refrigerant R-410A 8/14-LB/OZ 8/14-LB/OZ Line Size-(in.)O.D.Gas c 3' 7/8 7/8 Line Size-(in.)O.D.Liquid<_ 3/8 3/8 Charge Spec.Subcooling 8° 8° Dimensions H x W x D(Crated) 46.4 x 351 x 38.7 46.4 x 35.1 x 38.7 Weight-Shipping 280 280 Weight-Net 244 244 Start Components NO NO Sound Enclosure NO NO Compressor Sump Heat YES YES Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X084 AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 Snow Leg-Base&Cap 4"High BAYLEGS002 BAYLEGS002 Snow Leg-4"Extension BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 Sound Enclosure BAYSDEN004 BAYSDEN004 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 Seacoast Kit BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 Refrigerant Lineset TAYREFLN3" TAYREFLN3* O Certified in accordance with the Air-Source Unitary Heat Pump equipment certification program which is based on ARI Standard 210/240. ®Calculated in accordance with N.E.C.Onty use HACR circuit breakers or fuses. O Standard line lengths-60'.Standard lift-60'Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0'.('denotes latest revision) © For accessory description and usage,see page 5. ® •=15,20,25,30,40 and 50 foot lineset available. 6 22-1792-09 , . 0 TAE` Model Number Description - 3-10Ton W S C 1 2 0 E 4 R 0 A * * 1 2 3 4 5 6 7 8 9 10 11 12 13 Digit 1 - UnitType M Low Leak Economizer with Reference Digit 23 - Refrigeration Controls W Packaged Heat Pump3 Enthalpy with Barometric Relief 0 No Refrigeration Control3 P Low Leak Economizer with 1 Frostat"13 Digit 2 - Efficiency Comparative Enthalpy with 11 2 Crankcase Heater -11 Standard Efficiency Barometric Relief 3 Frostat and Crankcase Heater11,13 Digit 3 -Airflow Digit 15 - Supply Fan/Drive Type/ Digit 24- Smoke Detector C Convertible Motor 0 No Smoke Detector Digit 4,5,6 - Nominal Gross 0 Standard Drive4 A Return Air Smoke Detector9 Cooling Capacity (MBh) 1 Oversized Motor B Supply Air Smoke Detector 2 Optional Belt Drive Motor C Supply and Return Air Smoke 036 3Ton 6 SingleZoneVariableAir Detectors9 048 4Ton Volume(SZVAV)16 D Plenum Smoke Detector 060 5Ton 7 Multi-Speed Indoor Fan14 072 6Ton Digit 25 - System Monitoring 090 71/2Ton,Single Compressor Digit 16 - Hinged Service Access/ Controls 120 1OTon Filters 0 No Monitoring Control Digit 7 - Major Design Sequence 0 Standard Panels/Standard Filters 1 Clogged Filter Switch E R-410A Refrigerant A Hinged Access Panels/Standard 2 Fan Failure Switch Filters 3 Discharge Air Sensing Tube Digit 8 -Voltage Selection B Standard Panels/2" MERV 8 Filters 4 Clogged Filter Switch and Fan 1 208-230/60/1 C Hinged Access Panels/2" MERV 8 Fail Switch 3 208-230/60/3 Filters 5 Clogged Filter Switch and Discharge 4 460/60/3 D Standard Panels/2" MERV 13 Filters Air Sensing Tube W 575/60/3 E Hinged Access Panels/2" MERV 13 6 Fan Fail Switch and Discharge Air Filters Sensing Tube Digit 9 - Unit Controls Digit 17 Condenser Coil 7 Clogged Filter and Fan Fail Switches R ReliaTelT" Microprocessor Protection and Discharge Air Sensing Tube A Condensate Drain Pan Overflow Digit 10 - Heating Capacity 0 Standard Coil Switch 0=No Electric Heat F=14 kW(1 phase)' 1 Standard Coil with Hail Guard B Clogged Filter Switch and A=5 kW(1 phase)1 G=18 kW(1&3 phase) 2 Black Epoxy Pre-Coated Condenser Condensate Drain Pan Overflow B=6 kW(3 phase) 3=23 kW(3 phase) Coil Switch C=9 kW(3 phase) K= 27 kW(3 phase) 3 Black Epoxy Pre-Coated C Fan Failure Switch and Condensate D=10 kW(1 phase)1 N = 36 kW(3 phase) Condenser Coil with Hail Guard Drain Pan Overflow Switch E=12 kW(3 phase) P= 54 kW(3 phase) Digit 18 -Through-the-Base 0 Discharge Air Sensing and Condensate Drain Pan Overflow Digit 11 -Minor Design Sequence Provisions Switch A First Sequence 0 NoThrough-the-Base Provisions E Clogged Filter Switch,Fan Failure Digit 12,13 - Service Sequence A Through-the-Base Electric6 Switch and Condensate Drain Pan ** Factory Assigned Digit 19 - Disconnect/Circuit Overflow Switch Breaker(three-phase only) F Clogged Filter Switch,Discharge Digit 14 - Fresh Air Selection Air Sensing Tube and Condensate O No Fresh Air 0 No Disconnect/No Circuit Breaker Drain Pan Overflow Switch A Manual Outside Air Damper 0-50%2 1 Unit Mounted Non-Fused G Fan Failure Switch,Discharge Air B Motorized Outside Air Damper Disconnect6 SensingTube and Condensate 0-50%12 2 Unit Mounted Circuit Breaker6 Drain Pan Overflow Switch C Economizer, Dry Bulb 0-100% Digit 20 - Convenience Outlet H Clogged Filter Switch,Fan Failure without Barometric Relief5 Switch, Discharge Air Sensing 0 No Convenience Outlet D Economizer, Dry Bulb 0-100% and Condensate Drain Pan Overflow with Barometric Relief5 A Unpowered Convenience Outlet Switch E Economizer, Reference Enthal B Powered Convenience Outlet ° py (three-phase only)? Digit 26 - System Monitoring 0-100%without Barometric Relief5 Controls F Economizer, Reference Enthalpy Digit 21 - Communications 0-100%with Barometric Relief5 Options 0 No Monitoring Controls is G Economizer,Comparative A Demand Control Ventilation (CO2) 0 No Communications Interface B Low Leak Economizer with FDD(Fault Enthalpy 0-100%without 1 Trane®O Communications Interface Detection&Diagnostics) Barometric Relief5 2 LonTalk®Communications Interface g H Economizer,Comparative C FDD(Fault Detection&Diagnostics) Enthalpy 0-100%with Barometric 6 BACnetO Communications Interface with DCV(Demand Control Reliefs Digit 22 - Refrigeration System Ventilation) K Low Leak Economizer with Option Barometric Relief 0 Standard Refrigeration System8 20 PKGP-PRC013J-EN 0 TRAIN General Data Table 3. General data -6-10 tons -standard efficiency(continued) --__� 6 Tons 71/2 Tons 10 Tons I WSC072E3,4,W WSC090E3,4,W ✓/ WSC120E3,4,W Outdoor Coil-Type Lanced \,..\ Lanced _-- Lanced Configuration Full Face Full Face Intertwined Tube Size (in.) 0.3125 0.3125 0.3125 Face Area (sq. ft.) 17.00 19.83 25.56 Rows/FPI 3/16 3/16 3/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Indoor Coil-Type Lanced Lanced Lanced Configuration Full Face Full Face Intertwined Tube Size (in.) 0.3125 0.3125 0.3125 Face Area (sq. ft.) 9.89 12.36 16.65 Rows/FPI 4/16 3/16 4/16 Refrigerant Control Orifice Orifice Orifice Drain Connection Number/Size (in.) 1 3/4 NPT 1 3/4 NPT 1 3/4 NPT Outdoor Fan -Type Propeller Propeller Propeller Number Used/Diameter(in.) 1/26 1/26 1/30 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 cfm 5,800 6,200 6,900 Motor hp 0.70 0.75 0.75 Motor rpm 1,100 1,100 1,100 Indoor Fan -Type FC Centrifugal FC Centrifugal BC Plenum Number Used/Diameter (in.)/Width (in.) 1/12x12 1/15 x 15 1/19.7 x 15 Drive Type/No. Speeds/rpm BeltNariable/1,750 Belt/Variable/1,750 Direct/Variable(f) Motor hp (Standard/Oversized) 1.0/2.0 1.0/3.0 3.75/— Motor Frame Size(Standard/Oversized) 56/56 56/56 —/- Filters(9) -Type Furnished Throwaway Throwaway Throwaway Number Size Recommended (4) 16x25x2 (4)20x25x2 (3)20x25x2 (2) 20x30x2 Refrigerant Charge(h) Pounds of R-410A 12.00 13.80 9.75/9.31 (a)Cooling performance is rated at 95°F ambient,80°F entering dry bulb,67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat.AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to±20%of nominal cfm. Units are certified in accordance with the Unitary Air-Conditioner Equipment certification program,which is based on AHRI Standard 340/360. (b)EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. (c)Integrated Efficiency Ratio(IEER)is rated in accordance with AHRI Standard 340/360.The IEER rating requires that the unit efficiency be determined at 100%, 75%, 50%and 25%load(net capacity)at the specified in AHRI Standard. (d)Heating performance is rated at 47°F ambient with 43°F wet bulb,70°F entering dry bulb,60°F entering wet bulb. High Temp. Btuh Rating includes the effect of fan motor heat.Units are suitable for operation to±20%of nominal cfm.Units are certified in accordance with the Unitary Air-Conditioner Equipment certification program,which is based on AHRI Standard 340/360. (e)Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. For additional information refer to Table 32, p. 49. (f) For multispeed direct drive rpm WSC values,reference Table 31, p. 49. (g)Optional 2"MERV 8 and MERV 13 filters also available. (h)Refrigerant charge is an approximate value. For a more precise value,see unit nameplate and service instructions. PKGP-PRC013J-EN 25 • TRANE General Data Table 2. General data -5 tons-standard efficiency{continued) 5 Tons WSC060E1 WSC060E3,4,W Outdoor Fan -Type Propeller Propeller Number Used/Diameter(in. 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 cfm 5,145 5,138 Motor hp 0.40 0.40 Motor rpm - _ 1,075 1,075 Indoor Fan -Type (Standard) FC Centrifugal FC Centrifugal Number Used/Diameter(in.)/Width (in.) 1/11x11 -- 1/11x11 Drive Type/No. Speeds/rpm Direct/5(e) BeltNariable/1,750 Motor hp 1.00 - 1.00 Motor Frame Size 48 56 Filters(f) -Type Furnished Throwaway Thr way Number Size Recommended (4) 16x25x2 (4) 16x25x2 Refrigerant Charge(g) Pounds of R-410A 10.0 10.6 (a)Cooling performance is rated at 95°F ambient,80°F entering dry bulb,67°F entering wet bulb.Gross capacity does not include the effect of fan motor heat.AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to±20%of nominal cfm. Units are certified in accordance with the Unitary Air-Conditioner Equipment certification program,which is based on AHRI Standard 210/240. (b)EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. (c)Heating performance is rated at 47°F ambient with 43°F wet bulb,70°F entering dry bulb, 60°F entering wet bulb. High Temp. Btuh Rating includes the effect of fan motor heat.Units are suitable for operation to±20%of nominal cfm.Units are certified In accordance with the Unitary Air-Conditioner Equipment certification program,which is based on AHRI Standard 210/240. (d)Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. For additional information refer to Table 32, p. 49. (e)For multispeed direct drive rpm WSC values,reference Table 31,p. 49. (f) Optional 2"MERV 8 and MERV 13 filters also available. (g)Refrigerant charge is an approximate value. For a more precise value,see unit nameplate and service instructions. Table 3. General data -6-10 tons-standard efficiency - 6 Tons 71 Tons 10 Tons WSC072E3,4,W WSC090E3,4,W WSC120E3,4,W Cooling Performance(a) Gross Cooling Capacity 78,000 94,000 126,000 EER(b) 11.4 11.1 11.2 Nominal cfm/AHRI Rated cfm 2,400/2,100 3,000/2,625 4,000/3,200 AHRI Net Cooling Capacity 75,000 89,000 118,000 IEER(C) 13.0 12.0 13.1 System Power(kW) 6.58 8.02 10.54 Heating Performance(d) High Temp. Btuh Rating 71,000 86,000 111,000 System Power kW/COP 5.95/3.50 7.41/3.40 9,04/3.60 Low Temp. Btuh Rating 39,000 48,000 69,000 System Power kW/COP 5.2/2.30 6.39/2.30 8.43/2.40 HSPF(Btu/Watts-hr) — — — Compressor Number/Type 1/Scroll 1/Scroll 2/Scroll Sound Outdoor Sound Rating (dB)(e) 89 89 87 continued on next page 24 PKGP-PRC013J-EN 0 77MNIE Dimensional Data Figure 19. Heat pump-71 tons standard efficiency Note: All dimensions are in inches/millimeters. 1Or MIS i EVAPORATOR 6EOTION ,--CONDENSER FAN ACCESS PANEL • - / 48 71R 1i70M31 r 4114 108 MAN ^-- ALTERNATE CONDENSATE ORAN \ AT CONNECTION 34-14 NTT D A.HOLE �_ 341? ' `�I 772 W 77 WIR \ ® 1 AII��I' CONDENSER COIL 701 MAI '` UNIT CONTROL WIRE HOLE ipp, - 1221!MI \� �� - SERVICE ON1BE PORT ACCESS IIII Er a 51 9761 W 2441491�..4/'I-�4114 l air( h MA.HOLE illpp, t W r j 3 14 Mfr POWER WIRE W 1 Mr(761/8)DIA HOLE 7S6 174 AM 55114' 2 ECTIL ODM4ECTlo14� 1763 M$111 H 741C/ (6NDLE PONT POWER WHEN HER INSTALLED) CONTROL AND COMPRESSOR ACCESS PANEL Figure 20. Heat pump-71/2 tons standard efficiency-downflow airflow supply/return through-the-base utilities Note: All dimensions are in inches/millimeters. 92 1 -- 17 1/2' 9 7 I7 1/2- �— 444 W `251 Mlle z li ma`N 1 - � I . ■ RETURN SUPPLY .;� • ' 32 I/6' 83383-41 /-"?...----------4 \\. A�f r r4jl//A4w\.lJ\� \101‘kwk",.,1> ,,I.,a i `,., THROUGH TIC ,``+--- /, USE CLRIOC TEAT( y ` t 2 3/4• 1 71 IIM }6 )/' Ila .� J I Mew 27 5/7' y s. 701 141 TI D.AN THE (27 1(1r-- i ELSE ELECTRICAL T -49/IM g• l'767/6L 2 PKGP-PRC013J-EN 79 • TRANE Dimensional Data Figure 21. Heat pump -71/2 tons standard efficiency - horizontal airflow supply and return Note: All dimensions are in inches/millimeters. "'.. _ 37/8" 98 MM t(rs:, - TM �----- r� - ----"` 9 3•�8" f-- I Return j 321/4" I I I I I 425 MM 832 MM I Supp Y I 191/4' '237/8" I ' 489 MM 606 MM 11 1 . I `�_ 4 3J4 1 � •' . %_ 120 MM . � 27 5/8' 4 1/4" 1_ ..! 701 MM 108 MM 3/4-14 NPT DIA.HOLE CONDENSATE DRAIN Figure 22. Heat pump-71 tons standard efficiency- unit clearance and roof opening Note: All dimensions are in inches/millimeters. CLEARANCE CLEARANCE 36" (914 MM) HORIZONTAL FLOW-18° (457 MM) \ DOWNFLOW 36"(914 MM) / I -. TYPICAL ROOF OPENING CLEARANCE FROM TOP OF UNIT 72" -. 46'\\ 88 5/8" (1168 MM) 46" \ (2251 MM) (1168 MM) \� /531/4 A (1352 MM) CLEARANCE 48"(1219 MM) CLEARANCE 36" (914 MM) 80 PKGP-PRC013J-EN • TRE Dimensional Data Figure 23. Heat pump-71 tons standard efficiency - roof curb Note: All dimensions are in inches/millimeters. 3b. c(\A Mai c�Fy 4AP P PNC� 46 3/8 4//�-r��` L� R 178 NM) 1- ue o M�, // YCF "6' G c873/MI) (23MM) U685MM> l84 (91 14 ' 09-:\._ �jy� 1s 1i2 80 it' r9`Sj�I''11M, (356 MM) ` /� �q-��470 MM) (2045 l�l) a3 7/8' *4 ,7` R SMM>_ (2130 MM) Q,Q k O u�i� \SVpP\: N(23.,,7) <>0+7 c M�J Mr4) G`cPRPNCE 51 Figure 24. Heat pump-71 tons standard efficiency downflow-duct connections field fabricated Note: See p. 17 for duct clearance to combustible materials. Note: All dimensions are in inches/millimeters. t'451MM -y t,`/ 173/4", / / Oirs7 MM 33 3/4" 857 MM/ 4 i __________ / i 33314' i857MM i i i i � ALL FLANGES 1 1/4"(31 MM) ii e 1 /4 y= 1 PKGP-PRC013J-EN 81 . . • TRANE* Weights Table 53. Maximum unit&corner weights(lbs)and center of gravity dimensions (in.) Maximum Model Unit Weights(a) Corner Weights(b) Center of Gravity (in.) Tons Model No. Shipping Net A B C D Length Width 3 WSC036E 589 514 177 107 113 117 29 20 4 WSC048E 600 525 181 109 115 119 29 20 5 WSC060E 825 682 228 177 114 163 38 24 6 WSC072E 835 740 235 196 140 168 40 22 — 71/2 WSC090E 902 804 255 217 153 180 41 22 10 WSC120E 1388 1199 342 328 259 270 49 28 (a)Weights are approximate. (b)Corner weights are given for information only. CENTER OF GRAVITY LENGTH A — - a CENTER GRAVITY WIDTH D C CENTER OF GRAVITY Table 54. Factory installed options (fiops)/accessory net weights(lbs)(a),(b) WSC036E-048E WSC***E WSC072E-090E WSC120E Net Weight Net Weight Net Weight Net Weight Accessory 3-4 Tons 5 Tons 6-71/2 Tons 10 Tons 460 V IDM Transformer(C7 29 29 Barometric Relief 7 10 10 10 Belt Drive Option (3 phase only) 31 31 — — Coil Guards 12 20 20 30 Economizer 26 36 36 36 Electric Heaters(d) 15 30 30 40 Hinged Doors 10 12 12 12 Low Leak Economizer 68 93 93 93 Manual Outside Air Damper 16 26 26 26 Motorized Outside Air Damper 20 30 30 30 Oversized Motor 5 8 8 — Powered Convenience Outlet 38 38 38 50 Powered Exhaust — 80 80 80 Roof Curb 61 78 78 89 Smoke Detector, Supply 5 5 5 5 Smoke Detector, Return 7 7 7 7 Through-the-Base Electrical 8 13 8 13 Unit Mounted Circuit Breaker 5 5 5 5 Unit Mounted Disconnect 5 5 5 5 (a)Weights for options not listed are<5 lbs. (b)Net weight should be added to unit weight when ordering factory-Installed accessories. (c)Apply weight with all 460V units with the Standard Direct Drive Motor. (d)Applicable to Heat Pump units only. 86 PKGP-PRC013J-EN J YgNITTAI , Part Number: Unit Hold-Down Brackets for Trane and FORM NO. 3262-1P DATE: 10/03 American Standard YSC, YHC, TSC, THC, MH-PRC-HOLD SUBMITTED TO WSC, 036-120 COMPANY: DRAWN BY: M.HARGIS JOB NAME: EQUIPMENT: NOTES; a s1 Y ly 1 9 ,FEATURES: 4 . • Manufactured from 16 ga galvinized steel • Package includes four(4)hold-down brackets thirtytwo(32)#10 x 1/2"tek screws eight Ter / „ ,, bracket ' Unit base rail , I■f-' i ; Attach to curb _ (4)#10x 1/2" — Tek screws - Attach to unit(4 ea.)#10 x 1/2"Tek screws 0 it000lliro „lie'o Roof curb '/- THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. M IC ROM ETL CORPORATION•3035 N.SHA DELAN D AV EN U E,SUITE 300•INDIANAPOLIS,IN.48226•1.800-882-4822-•M IC RO M ETL WEST•202 SOUTH 18TH ST.•SPARKS.N v mall•i-ann-nne_eaRI Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10114 SW WASHINGTON SQUARE RD, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2014-00428 Chip Barnett Violation Summary: Inspector Contractor