Plans
Mainlander; Commerce Plaza Exhaust Hood System Carlson Services Inc. 1 RECEIVED .. EXI-tA(A ST FAN MAR JUL 16 2013 DI.tCT 11, ex-r RIOR CITYUFTIGARD BUILDING DIVISION CM IA WALL-TO EXTERIOR 'I CITY 91 F TIGARD Approved ............. [L]-•-•- Conditionally Approved. [ ] See Letter to:Fo l low [ I Attached [ Permit Number: •" bfr ;4s < 9 Ad. • : *-4-04,- .114 .1 �►y l3a By: _Wan, Date: n77 I HOOD MAW., P A I R D IA.CT Approved plans shall be on job site. ` KITCH-FN OFFICE COPY TPctax. ss t ."7--E. HOOD INFORMATION - Job#1 7805 7 EXHAUST PLENUM HOOD ONFIG. MAX. TOTAL HOOD i, MODEL LENGTH COOKING TOTAL R[SER(S) SUPPLY HOOD END TO No. TEMP. EXH. CFM WIDTH LENG. DIA. CFM S.P. CFM CONSTRUCTION END RDW 5418 9' 0.00' 10' 20' 2646 -0.550' 430 SS 1 600 Deg. 2646 1588 ALONE ALONE SND-2-PSP-F Where Exposed, JIOOQ INFORMATION F ILTER(S) LIGHT(S) UTILITY CABINETS) FIRE HOOD t HOOD FIRE SYSTEM ELECTRICAL SWITCHES NO. TYPE QTY.HEIGHT LENGTH QTY. TYPE WIRE LOCATION SYSTEMHANGINO GUARD TYPE SIZE MODEL k QUANTITY PIPING WGHT 1 SS Bo FFIe with Handles 3 20' 16' 3 Incandescent Light Flat NO Wall lint Ansul 8102 3.0/1.5 YES 473 3 20' 20' LBS . HOOD OPTIONS ' HOOD OPTION NO 1 INSULATION FOR TOP OF Hoop INSULATION FOR BACK OF HOOD PER?ORAT,4D SUPPLY• LEN M(S, HOOD R SEWS) —_..... NO POS. LENGTH WIDTH HEIGHT TYPE WIDTH LENG. DIA. CFM S.P. 1 Front 108' 18' 6' MUA 12' 24' 794 0.237' . MUA 12' 24' 794 0.237' I' LAYER OF INNTERNION FACTORY 61( v INSTALLED IN INTERNAL BACK STANDOFF, e��__ MEETS 0 INCH REQUIREMENTS FOR i(\P , ` CLEARANCE TO COMBUSTIBLE SURFACES. Field Cut 1 , 0' x 20' Exhaust /�` Riser ���' ) 54' U.L. Listed Incandescent Light '�....., Fixture-High Temp Assembly C S S S 'r-o-P--- - 24 -- 24 - riL-,`13 o 01 18' 12' / 12' DJ 1-0 9' 9' e .t ' o cr `� ' LAIC. � � I-6 27' 54' I 27' 9' 0.00'Nom,/9' 0.00'OD PLAN VIEW — Hood #1 9' 0.00" LONG 5418SND-2—PSP—F JOB Tigard Hood E��1� = ® LOCATION PORTLAND, OR RE DATE 5/14/2013 JOB# 1780537 i DWG# 1 DRAWN BY • REV. SCALE 3/8' = 1'-0' INCANDESCENT LIGHT FIXTURE-HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 1' LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES 54' FIELD CUT EXHAUST RISER ATTACHING SUPPLY RISER HANGING ANGLE P PLATES WITH VOLUME DAMPER q' • 23.5% OPEN STAINLESS • 20' SS BAFFLE WITH jq• STEEL PERFORATED PANEL HANDLES AND HOOK,, t 7 6' I' LAYER OF INSULATION FACTORY — INSTALLED IN 3' INTERNAL STANDOFF. % / 18' �I 118' NOM MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. % ,� IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE r 27' MIN. ----I AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 48.0' MAX GREASE DRAIN WITH REMOVABLE CUP 1 80' AFT TYP. EQUIPMENT BY OTHERS T1 FT SECTION VIEW - MODEL 5418SND-2-PSP-F HOOD - #1 JOB Tigard Hood ��� L O Cp77Jtj LOCATION PORTLAND, OR C DATE 5/14/2013 JOB# 1780537 DWG# 2 DRAWN BY REV SCALE 3/8' = 1'-0' ' EXHAUST FAN INFORMATION - Job#1760537 FAN UNIT FAN UNIT MODEL • MODEL TAG CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.)SONES NO I NCAI6FA NCAI6FA ' 2646 0.750 936 1.000 3 208 3.3 154 11.8 MUA FAN INFORMATION - Job#1780537 FAN UNIT FAN UNIT MODEL A BLOWER HOUSING TAG CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.)SONES i NO 2 INLINE2-G12 G12 INLINE.2 2385 0.500 688 0.750 3 208 2.7 283 8,2 FAN OPTIONS FAN UNIT OPTION (Oty. - Descr) NO. I I - Grease Box 1 - Extra Set of Betts 1 - Wallnount 27.5 sq. x 2' 2 1 - Extra Set of Belts 1 - INLINE2 Indoor Hanging Option - Includes 2 HSA125 Hanging Spring Isolators per Uni-Strut ' FAN ACCESSORIES FAN FAN EXHAUST SUPPLY UNIT UNIT NO. TAG GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT 1 YES YES 2 YES FAN #1 NCA16FA - EXHAUST FAN WALL MOUNT BRACKET WALL MOUNT BRACKET 1-7 WALL �G 39 3/8 FEATURES, 18 GAUGE STEEL 1/` -ROOF MOUNTED FANS 24' -RESTAURANT MODEL -UL705 AND UL762 UNIT I'-' 28 -AMCA SOUND AND AIR CERTIFIED ' 24' � '/ -WIRING FROM MUTER TO DISCONNECT SWITCH `vowrIN - WEATHERPROOF DISC0&CT 'II-HIGH HEAT OPERATION 300T(149'G 'GREASE CLASSIFICATION TESTING 27 /• C� — NORMAL TEMPERATURE TEST ` \ WALL OPENING I"�"I 22 5ie WHILE FAN MUST OPERATE COATNWC) _\Ill WHILE E%HAUSTING AIR AT 300'F(149'C) UNTIL ALL FAN PARTS HAVE REACHED NIIIP THERMAL EQUILIBRIUM,AND WITHOUT ANY •• CENTER CUT r t;IAM Romp DETERIORATING S EFFECTS TO THE FAN WHICH 'EA SE DRAIN vOULD CAUSE UNSAFE OPERATIOI. - WALL BRACKET FIT$ INTO BASE OF FAN 2 ABMORMAL FLARE-UP TEST - SELF DRILLING SCREWS SHOULD BE USED TIM—Er�A EXHAUST FAN MUST OPERATE CONTINUOUSLY FOR UNIT ATTACHMENT TO WALL MOUNT BRACKET / 1 WHILE EXHAUSTING PERIOD VAPORS ■ DIMENSION = 5' WHEN USED WITH DAMPER OF •• CENTERED IN WALL MOUNT 15 MINUTES WITHOUT THE FAN BECCNING —16 1/2 DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. ------I9 1/2 39 2A OPTIONS 28 GREASE BOX EXTRA SET OF BELTS PIIPIIPPIIII WALLMOUNT 27.5 SQ. X 2' DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) ' • JOB Tigard Hood `�T�^ LOCATION PORTLAND, OR 0 if DATE 5/14/2013 JOB# 1780537 , DWG# 3 DRAWN BY ■ REV. SCALE 3/8' = 1'-0' FAN #2 INLINE2-G12 - SUPPLY FAN I. INLINE SUPPLY UNIT W/ 12' BLOWER IN SIZE #2 HOUSING. INSULATED HOUSING. 2. SIDE DISCHARGE - AIR FLOW RIGHT -) LEFT 3. EXTRA SET OF V-BELTS. ONLY TO BE ORDERED AS FAN OPTION AT TIME FAN IS ORDERED. • I 4. INDOOR HANGING CRADLE FOR THE SIZE 2 UNTEMPERED INLINE UNIT. 2 HSA125 HANGING ISOLATORS PER UNI-STRUT INCLUDED. I 0 0 0 • I I 37 3/8' rLE� 10 1/8' 15 3 4• V°RING 22 3/4' LIFTING LUG o 'r . � 11. INTAKE FILTER I'I AIRFLOW ......._r, I 10111111. 13 9/16' II II 136 3/4' SERVICE DISCONNECT SWITCH 124. 13 1/16' ._• BLOWER/MOTOR • ACCESS DOOR 24' SERVICE 00 CLEARANCE REQ. - I A 3 3/4'03 ] ,� • E 9 5 3/4' \ UNI-STRUT BASE — -- 3 1/4' UNI-STRUT BASE FOR HANGING FOR HANGING —48' 36 7/8' 48' I i JOB Tigard Hood In L LOCATION PORTLAND, OR ....P.. DATE 5/14/2013 JOB# 1780537 DWG# 4 DRAWN BY REV SCALE 3/8' = 1'-0' • ELECTRICAL PACKAGES - Job*1780537 N0. TAG PACKAGE * LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE ! H.P. VOLT FLA I Light 1 SC-3,m,, Vall Mount In SS Box SS Wan Naunt Box Smart Controls Thermostatic Control Exhaust 3 1.000 208 13 I Fan Supply 3 0.750 208 2.7 II • JOB Tigard Hood c* E� 0 c4PT1Yi LOCDATE ATION PORTLAND, OR C 5/14/2013 JOB# 1780537 awe es. DWG# 5 DRAWN BY REV. SCALE 3/8' = 1'-0' Exhaust Fan Wiring JOB NAME Tigard Hood DATE 5/14/2013 DRAWING NUMBER EXH1780537-1 JOB NUMBER 1780537 MODEL NCA16FA Installed Options 1 BK r---� BK 2 �K c I BK MT-DI GR GR O- 0 I LAW-01J Component Identification 3 0GR - Label Description Location MT-01 Fan Motor (21 4 SW-01 Main disconnect switch Cal 5 6 7 8 9 10 11 12 13 14 15 MOTOR INFQ 16 EXHAUST 1HP-208V-3P-3.3FLA 17 18 MOTOR/CONTROL AMCA: .2A ATION MOTOR/CONTROL MOP, 15A 19 20 NOTES ----- DENOTES FIELD WIRING 21 DENOTES INTERNAL WIRING 22 WIRE COLOR BK - BLACK YW - YELLOW HL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE PR - PURPLE 23 RD - RED PK - PINK WH - WHITE CAirHandler Wiring JOB NAME Tigard Hood DATE 5/14/2013 DRAWING NUMBER A1780537-2 JOB NUMBER 1780537 MODEL INLINE2-G12 (ATTENTION ELECTRICIAN( Installed Options DROP FOR DISCONNECT CONNECTION IS FACTORY SUPPLIED CONNECT POWER TO THE DROP 1 BK BK 2 �K i o I BK MT-01 GR• o- r 06 BK pGR - gW OIJ Label Component Identification L 3 Location MT-01 Supply rotor [21 4 5 6 SW-01 Main disconnect switch (20 7 8 9 10 11 12 13 14 15 MOTOR INFQ 16 SUPPLY 0.75HP-208V-3P-2.7FLA 17 18 I.�EECC R�J[ L IN �R N MOTOR CONTROL ACIRCUIT MACA�3.4A MOTOR/CONTROL CIRCUIT MOP: 15A 19 20 NOTES ---- DENOTES FIELD WIRING 21 DENOTES INTERNAL WIRING 22 WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY • 23 OR - ORANGE PR - PURPLE ` RD - RED PK - PINK WH - WHITE /.108 NO MODEL NUMBER SC-311110FP DRAWN BY 5 INST INSTALL 1780537 JOB NAME DATE °M6 NO Tigard Hood 5/14/2013 ECP #1-1 DESCRIPTI❑N OF ❑PERATI❑N' 3 Phase w/ I Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out In Fire, Fan(s) On/Off Thermostatically Controlled. 1 2- • 1 BREAKER PANEL TO HOOD CONTROL PANEL HOOD PANEL ALL SWITCHES FACTORY WIRED 1 Responsibility' Electrician TO p.4.1_CAT-5 CONNECTION 3 SWITCHES BREAKER PANEL HOOD PANEL _ 4 Not_- BREAKER 1PH - HOOD PANEL T1AO- 120 V -- -- _ Neutral - Ground `� TO [ TIB�'WIRE TO CONTROL BOARD. J 15 A � KITCHEN TEMP ROOM TEMP 5 CONTROL POWER. DO NOT WIRE SENSOR MOUNTED IN ROOM AWAY TO SHUNT TRIP BREAKER. SENSOR FROM HEAT SOURCES. SEE MANUAL _ BREAKER IPH I Not _M270 - Neutral 6 120 V - - aff' HOOD PANEL I -4 15 A HOOD LIGHT SWITCH #1 TO 7-Va WIRE TO CONTROL BOARD. HOOD 11 INPUT POWER DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT RISER 1 7 BREAKER 3PH --------LINE---_Ia 208 V LINE THE FOLLOWING CONNECTIONS LINE MAY OR MAY NOT BE 8 l5 AMP EXH-1 REQUIRED BASED ON JOBSITE SPECIFICATIONS &SUP-2 SHUNT COIL 9 ' HOOD PANEL C.'ST'_rl HOT TO SHUNT COIL SIGNAL FOR �� NEUTRAL FROM SHUNT COIL-_-_ EXTERNAL ST TERMINAL IS ENERGIZED 10 SHUNT TRIP IN FIRE CONDITION. HOOD CONTROL PANEL TO FANS / MUA 11 Responsibility' Electrician HOOD PANEL COMMON HOOD PANEL FANS SPARE FIRE - NORMALLY CLOSED L SYSTEM DRY LTR NORMALLY OPEN FAN: 01 EXH-1 . SPARE CONTACTS USED WHEN FIRE 12 Load Wiring I TI LOAD LEG I -0--0 CONTACT 'SYSTEM DISCHARGES TO DISABLE ST-1 I�_L -LOAD LEG 2 --�o l(NOTPFORTBUIILD NPROVIDE SIGNALS. ARM) • WIRE DIRECT a---LOAD LEG 3 w"c 13 TO STARTER IIMI--- -WQ1ND - --I di, WIRE TO DISCONNECT 14 FAN, 02 SUP-2 Load Wiring L.f1"D LEGJ • o 15 ST-2 I T20-- �o,0s ; a WIRE DIRECT Lr C- LOAD LEGA • o TO STARTER IN----- 'D I. 16 WIRE TO FACTORY PROVIDED CONDUIT DROP 17 • 18 HOOD CONTROL PANEL TO ACCESSORY ITEMS Responsibility' Electrician 19 HOOD PANEL COMPONENT MICROSWITCH I I 20 HOOD PANEL =I - Q:y'-- C TO CNN WIRE C TO COMMON. J FIRE SYSTEM WIRE ARI TO NORMALLY CLOSED. 1 21 MICROSWITCH CI TO AR1 SHOULD HAVE CONTINUITY WHEN ARMED. MICROSWITCH 1 IF MORE THANcKC 22 ONE FIRE SYSTEM [ ._ I MICROSWITCH 2 WIRE IN SERIES 1_- - CS C 23 AS SHOWN HERE HOOD LIGHTS I HOOD PANEL BLACK___J 24 TO WHITE -I HOOD LIGHTS GREEN 25 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD / • • -- •A I B I C I D I E I F I G I H I I \ r. FACTORY WIRING UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. PUT END OF LINE PLUG IN MOTOR POWER CIRCUIT SCHEMATIC SWITCHES EMPTY RJ45 JACKS, PH EOLIMA CIRCUIT BOARDS ▪ 1 J9 120V CAT-5 CABLE 3' REG ECPN03 Rev. 1.21 ,—: I HMI 1 1 HMI Rev, 1.05 l4 AVG ST-1 EL-1 MTR,EXH-1 • ,`. vH- e� CONTROL INPUT Z n .—. �'CPM03 3 pH A ' LI T4 �,x,c 1 CON T+100-KOSDIO _.n 120VAC HI=LINE, Bi:CiIC v t' ' _.7,,,t1; _„,,,,74 7i 2 OVLD:193-K B40 • �T:j�® ® -nyt.ate `i 0 tom.V i7*-u.. _ FLA�3.3 a'- A RD x _- NIANBREAKE, vH�BL 15 AMP I1 -�5 - •'JC.^ tl2LA.AC 244EAY � '�® 15A BREAKER, KO_*. (NM® DO NOT CONNECT DC ��, 14 AVG 1 Sr-2 GL 2 NUR,SUP-2 KO-4 e_ CA NC 2 g{,y S TO SHUNT TRIP 24V OlJl�© BK IIA -TI ,, r1 CON T1100-K051110 COBPS-01 j6 0000(400 �il�i T INSTALLATION C -'-t S• fOtCOM .I BK � SCHEMATIC FOR — 1� ADDITIONAL REQ. n : :a.:A:Y/�(3 _ �,41aZT3 . 2 Z U [7 .,'iti c,,rta PANEL LID'I [ =�L c Ph Ann ec. x C.rrlosd PA wits 3 c, Tkntecty rertes _ -I V 0-0181!4p11.17 Eyy/ 24VDC .n n I R'DT '1v0C mph Inrush Rh 798.324-1419h-In. 4 J7 120V �-- YV_1,AVG RD-1-HI YV _ (� �C Via- HOOD LIGHT INPUT. BK `•� 15A 1400V MAX. 00D�IXGHTS �JUMPER�- BK pp���11 > 5 rAw p.) F s BK 9E'Y97 ■ • Ft. 9i 7 . i `: • p NI NI • 6 HI HI DC+>BL PR, ;R01 ARIOBK vH<NI calt) i 7 WANG IR-RAM YV-YELLOW BL-R-t;E GY-GREY A-7i PR-Rini F RD-RED Ap/2L-6S1ffi.STRIFE R0' "RAO STRIPE =..is X1/0'1 STRIPE v'•/BL STRIPE t 8 l` DRY CONTACTS (SHOWN DE-ENGERGIZED) ( 111�8 "'"E ■ 14 AWL RA-1-1 orli p+a ---el:rllk • ON/OFF - .3( ients -- 4e,/•••• `_ 11Th FIRE OF OPERATION -- hr' -_ 1'W 3 Plxs'i s/ I EV ust Pan, I supply Fan, Ewhe14.t.on In Fire,9 LIONtA out In FFe, F3ni,1 Or+/QPF Thetalo93at/ply ConVptifd. iss�-1) • I 0 TM78iII 37 --(Ammar FA?c�j Tn4/ZO 3 . . , . / `D150�Evo 11-1 ./I