Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
PHILLIPS RECEIVED ELECTRONICS EST. 1952 JAN 0 2 2014 CITY OF TIGARD BUILDING DIVISION 3247 NW 29th Avenue phillipsalarm.com Voice: 503-222-5083 Portland,Oregon 97210 Fax: 503-227-4992 Scope of Work Installation of the following devices for the fire alarm system 1. Replace the existing combo burglar alarm/fire alarm system with a new fire alarm control panel 2. Connection to the existing fire alarm devices 3. Install a dual path fire alarm communicator at the fire alarm control panel CIT} py TIGARD Approved..T.T. a ,. Conditionally Approved [ ] See Letter to:Follow [ ] Attac ed.. Permit Num•- v ' ateAstS Ad• . 1 :, . C .4) By: _ XII Date: KIM Approved plans shall be on job site. OFFICE COPY I • -- - — ---- ---1 NA= iii / vol J 0 y'9 , s 11 Ns al ' I - — ;©'4 s % 11 TIGARD REMODEL NOTES 4 7 ?�? 11 t T an - a i. na,r IMO r.. — I _ Yon. WAN r..,inn r I.r auaa rr•am y 1) �_. p� rr.er.n WA mil r.Ar a a a.n 1 11 - � era �ar.,/f a` 1_ 11 ..._.-- I N.a/a Mw.aw.raa,aMMM..L armour *dm II -,.L I_ - T I. Q4 as . -,Ili NG() - Fire Alarm Con4rol Pore 11 �-•:� 11 ®- •II G - Fire Ma+rnn CoMmuo'cJor. ZS IESEE1 !i1 I �f 4 - Dorn S�rabe 1 A VI a ®®4 - Sfro1be. IA _ — _ II l I © . Sr "lee cfe.ector — S S S —�_ Er ©, - rGw,Pe - us —7� 11 II d - Floes _ - A - Pint s4 4,a., 7 A - A∎n�nthc�S�ro✓ z S S S S �s - 3 9. - 4 A It 1 r----mm-- I 0 TIGARD- c1 NEW .447-—iffid "� FIRE ALARM CONTROL PANEL . 41% SILENT Model 5208 KNIGHT RECEIV ED Fire Alarm Control Panel by Honeywell JAN 02 2014 with Digital Communicator CITY OFTIGARD The Fire Alarm Control Designed to BUILDING DIVISION Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, .,. Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time .=MUM from the main control panel • Clock source setting options for 50 - • • Event History Buffer(150 events) Hz, 60 Hz, or intemal (uses the - • -: with date/time stamp panel's internal clock) • All zones are compatible with 2-or Specifications 4-wire detectors Operating Voltage: 24 VDC ' • 8 selectable/programmable output patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A • circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: �'„ -, relays Height: 24.75" (62.9 cm) .` • Programmable smoke verification, Width: 14.5" (36.8 cm) -. pre-alarm delay, cross zoning and Depth: 3-7/16"(8.73 cm) -4. enhanced verification mode features with 5/8"protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8" (67 cm) • Plex-2 Door Option control panel touchpad, remote Width: 17-3/16" (43.66 cm) . SK-SCK Seismic Compliance Kit annunciator, or Windows®SKSS Total Depth: 4" (10.16 cm) downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on-site (0°to 49° C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • OSHPD (CA) OSP-0065-10 • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) - while providing single button • 5220 Direct Connect Module operation of the reset and silence • 5824 Serial/Parallel Printer Interface functions Module • Programmable AC trouble relay • SKSS Downloading Software FIRE i:•LARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect _ _ For On-Site Programming 2 Class A (Style D) or Class B (Style B)♦— t _*Programmable Initiation Circuits `. Form C Relays 8 Class B (Style B) �� ,, fi _, Notification Initiation Circuits i ""` b Appliance Circuits o V • 6 r. . 5235 Remote II 0 1111 • - ,nav Annunciators Li __I C SBUS Devices -~' 5280, 5217, & 5824 1E1 L] 7 To AC ------ r�►7 • SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350318 Rev E subject to change without notice. For more information, contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical support,Please call 800-446-6444. www.silentknight.com REMOTE ANNUNCIATOR SILENT SK-5235 KNIGHT Remote Annunciator by Honeywell Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators. Call Silent Knight today for more information 1-800-328-0103. Operation • • When the system is normal and FIRE ALARM ANNUNCIATOR receiving AC power, the power AI AR0.1 NnuP.I LED is on and all other LEDs are SUPERVISOR/ SILFNCFD off. Other LEDs turn on as the • conditions occur. Users identify themselves to the control panel by entering a code 1 2 3 A on the annunciator. When a user RESET 4 5 6 presses a button, the annunciator o ENTER t piezo beeps and the LCD prompts 7 8 9 SILENCE the user to enter a code or other * o # V relevant information. Features SK-5235 Remote Annunciator • 2-line 16-character LCD display • Indicates Trouble, Alarm, Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage: 24 VDC SK5235 display Current Draw: Remote Annunciator • Each SK-5235 is individually Standby: 30 mA supervised by the SK-5208 Alarm: 50 mA FACP Dimensions: Compatible Products 3/16"7- • Up to 6 per SK-5208 FACP Width: SK5208 (18.26 cm) • Operation and appearance Height 5" Fire Alarm Control Panel comparable to the control (12.7 cm ) panel's on-board annunciator Depth: 1-1/8" • Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp: 32°to 120° F • OPR operator's key ships with (0°to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance: 1500ft will not open the control panel door Approvals - MEA 429-92-E • CSFM 7165-0559:137 • UL Listed '•REMOTE ANNUNCIATOR SK-5235 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of supporting up to 6 supervised SK-5235. Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire. I ., z _ ,iloiaaaLil II 0 • • SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA SS KNIGHT keep our product information up-to-date and accurate.Wpe cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350321 Rev C b Honeywell subject to change without notice. For more information,contact Silent Knight ©2010 Honeywell International Inc. y 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com Honeywell IPGSM-4G IP Internet & GSM (4G/3G/2G) Dual Path Communicator • General ---- The IPGSM-4G is a 4G fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel(FACP) that has a built-in dialer.This easy to install,dual path commu- nicator connects directly to the primary and secondary corn- munication ports of a Fire panel's Digital Alarm Communicator Transmitter (DACT). It offers three selectable reporting paths which include: (Cellular only), (IP only), or(IP primary/cellular backup). In the event of an off-normal condition,the fire panel sends contact ID formatted information to the IPGSM-4G com- municator panel. The IPGSM-4G then reformats the data into highly encrypted Ethernet packets for transmission to the Alarm-Net receiver via customer-provided InterneVlntranet connection or the GSM network. • Reliable connection: IP and GSM connection tested every Alternative communication methods are critical in the market- day. place due to VoIP(Voice over IP), migration from POTS (Plain • QOS: Quality of Service diagnostics via AlarmNet conveys Old Telephone Service) and growth of digital radio networks. vital communicator information including when message The IPGSM-4G's exclusive dual-path communications solution was received,signal strength,and message path used. combines Internet service with GSM for added reliability and • 7720P Hand-held programmer for easy setup. an extra level of security. All signals from the IPGSM-4G com- municator panel are delivered to Honeywell's AlarmNet Net- work Control Center, which routes the information to the Operation appropriate central station. The state of the art AlarmNet net- When an event occurs, the Fire Alarm Control Panel goes off work control center is fully redundant and monitored 24/7. hook to dial the central station.The IPGSM-4G Dialer Capture AlarmNet has the ability to route messages using AlarmNet-i Module detects the off-hook condition and provides the fire and 800 PLUS services, providing true redundancy and multi- panel with a dial tone. When the fire panel detects the dial path message delivery. tone, it begins dialing the central station. After the dialing is The IPGSM-4G is designed to operate over the most common completed,the Dialer Capture Module returns a handshake to GSM networks including 2G,3G and 4G. Its multi-GSM plat- the fire panel.The fire panel then sends the contact ID reports form technology automatically chooses the best available cel- to the Dialer Capture Module, which in turn sends a kiss-off lular signal in the area based on signal strength and after the report is successfully received from the fire panel. seamlessly self-adjusts to maintain critical life safety communi- The Dialer Capture Module sends the contact ID reports to the cation. IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- Features tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent • Saves the cost of two dedicated phone lines. on configuration). • Dual path communications. Can communicate to central station using Internet or cellular technology. Easy to Program • Requires no change to the existing Fire Alarm Control The IPGSM-4G communicator can be pre-programmed using Panel configuration. The IPGSM-4G connects directly to the 7720P programmer to enter all central-station information. the primary and secondary telephone ports. This is saved to the IPGSM-4G communicator panel memory. • Multi-GSM platform compatibility for 2G,3G and 4G. When the IPGSM-4G communicator is installed at the site and • Operates over the following communication protocols: connected to the Internet/Intranet, it registers itself with the HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) AlarmNet receiver. GPRS(2G). .For most installations,the only required parameters are: • Works over any type of customer provided Ethernet 10/100 • Primary City ID (two digits) obtained from your monitoring • Base network connection (LAN or WAN), DSL modem or station. cable modem. • Primary Central Station ID (two digits) obtained from your • Data transmits over standard contact-ID protocol but is monitoring station. secured with the industry's advanced encryption standard • Primary Subscriber ID(four digits)obtained from your mon- (AES 256 bit). itoring station. • Supports both dynamic(DHCP)or Public and Private Static • Communication Module's MAC ID, and MAC CRC number IP addressing. located on outside of box,and inside of the module. • Built-In Power Supply module. On board charging circuit All of these parameters are assigned by the monitoring station. design accommodates back-up battery. Includes primary power and battery supervision. NOTE: Some assembly is required. See Installation and Setup Diagnostic LEDs:Signal strength and status indicators. Guide#800-12454 for full details. • 4 Panel Capabilities Cabinet Specifications The IPGSM-4G is compatible with fire panels that use the Dimensions: 14.875'H x 12.75"W x 3.0"D(37.8 cm H x 32.4 Contact ID communications format as described in the SIA cm W x 7.6 cm D). DC-05 standard. Color: Red. AlarmNet Shipping Specifications Honeywell's AlarmNet has been the nationwide leader in Weight: 5.3 lbs. (6.94 kg). alarm communications technology since 1986.A reliable alter- Dimensions: 15.625" H x 13.79' W x 9.25' D (39.7 cm H x native for the transmission of alarm signals, our radio network 34.9 cm W x 23.9 cm D) provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- structure Temperature and Humidity Ranges • support. The AlarmNet network consist of redundant This system meets NFPA requirements for operation at 0 - hardware servers, hot back-up databases and generators with 49°C/32- 120°F and at a relative humidity 93%±2%RH(non battery back-up at all locations to ensure continuity of service. condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful Signals from Alarm-Net are transmitted to the central station's life of the system's standby batteries and the electronic com- receivers using multiple communications paths consisting of ponents may be adversely affected by extreme temperature the Internet, radio network or toll-free POTS service, ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with Installation Requirements a normal room temperature of 15-27°C/60-80°F. UL COMPLIANCE Product Line Information To meet UL864/NFPA,ensure the following: IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- • IPGSM-4G must be installed in accordance with NFPA cator Panel. Includes red cabinet with ademco key and lock, (National Fire Protection Association)standards 70 and 72. wall outlet box, Dialer Capture Module, iGSM Communications • IPGSM-4G must be mounted in the same room and within Module, antenna & mounting adapter, PowerBoostl power 20 feet of the fire panel. supply, LED display board, transformer, manual, & required • IPGSM-4G, and all equipment used for the IP connection screws,cables,etc. (such as the router, hub, modem, etc.)shall be listed, must GSM-ANT3DB: 3db gain external/remote antenna. be powered from an un-switched branch circuit,and be pro- 7626-50HC: 50 ft.antenna cable, low loss. vided with appropriate standby power. 7626-25HC:25 ft.antenna cable, low loss. • IPGSM-4G must use the 7AH battery(not supplied)to pro- WA7626-CA: SNA to N Adapter. vide 24-hour backup capability. 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. Electrical Specifications BAT 1270: Battery 12 Volts,7 AH,sealed. Transformer: —Primary 120VAC,60Hz,0.5A. Agency Listings and Approvals -Secondary: 18VDC, 50VA. The listings and approvals below apply to the basic IPGSM-4G Battery: communicator panel. In some cases,certain modules may not be —One 12 V 7.0 AH lead acid battery(not supplied). listed by certain approval agencies,or listing may be in process. —Battery charging current: 1 Amp maximum. Consult factory for latest listing status. —Battery discharge current: Standby 230mA, Active UL Listed: S789. 950mA. CSFM:7300-1645:0199. FDNY:COA#6150. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate at requirements.All specifications are subject to change without notice. 02013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techsery @honeywell.com www.honeywellpower.com DH-60769:8 June 2n t3 Made ISO 9001 Made in the U.S.A. ®U.S.Registered Trademark 02013 Honeywell International Inc. + ME Page 2 of 2 !MITT SYSTEMS - Global Project Values: SILENT Project Name: Goodwill Tigard Standby Hours. 24 KNIGHT Project ID:I Alarm Mins: 5 Prepared By Derating Factor: 1 2 SK-5208 Calculations Date: Voltage Drop Warning Version 02.26.09 Threshold%: 10 Panel ID: SK-5208 Model: SK-5208 Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Qty Standby Alarm &Type 1000 Ft. One-Way Ohms EOL �oDrop SK-5208 SK-5208 Main Control 1 0.140 0.550 SK-5217 SK-5217 Zone Expdr 1 0.060 0.260 SK-5235 SK-5235 LCD Remote 1 0.030 0.050 SK-5280 SK-5280 Display Mod 0.000 0.000 SK-5220 SK-5220 Dir Con Mod 0.000 0.000 SK-7181 SK-7181 Zn Cnvtr 0.000 0.000 IDC-1 Initiating Device Ckt 1 0.000 NA** IDC-2 Initiating Device Ckt 2 0.000 NA** IDC-3 Initiating Device Ckt 3 0.000 NA** IDC-4 Initiating Device Ckt 4 0.000 NA** IDC-5 Initiating Device Ckt 5 0.000 NA*` IDC-6 Initiating Device Ckt 6 0.000 NA** IDC-7 Initiating Device Ckt 7 0.000 NA** IDC-8 Initiating Device Ckt 8 0.000 NA** IDC-9 Initiating Device Ckt 9 0.000 NA" IDC-10 Initiating Device Ckt 10 0.000 NA** IDC-11 Initiating Device Ckt 11 0.000 NA** IDC-12 Initiating Device Ckt 12 0.000 NA** IDC-13 Initiating Device Ckt 13 0.000 NA** IDC-14 Initiating Device Ckt 14 0.000 NA** IDC-15 Initiating Device Ckt 15 0.000 NA** IDC-16 Initiating Device Ckt 16 0.000 NA** IDC-17 Initiating Device Ckt 17 0.000 NA** IDC-18 Initiating Device Ckt 18 0.000 NA** IDC-19 Initiating Device Ckt 19 0.000 NA** IDC-20 Initiating Device Ckt 20 0.000 NA" IDC-21 Inactive, Add SK-5217 0.000 NA'* IDC-22 Inactive, Add SK-5217 0.000 NA** IDC-23 Inactive, Add SK-5217 0.000 NA** IDC-24 Inactive, Add SK-5217 0.000 NA** IDC-25 Inactive, Add SK-5217 0.000 NA** IDC-26 Inactive, Add SK-5217 0.000 NA** IDC-27 Inactive, Add SK-5217 0.000 NA** IDC-28 Inactive, Add SK-5217 0.000 NA** IDC-29 Inactive, Add SK-5217 0.000 NA** IDC-30 Inactive, Add SK-5217 0.000 NA** NAC-1 Notification Appl Ckt 1 0.000 1.308 #16 Solid 4.02 0.00 20.40 0.00% NAC-2 Notification Appl Ckt 2 0.000 0.872 #16 Solid 4.02 0.00 20.40 0.00% NAC-3 Notification Appl Ckt 3 0.000 0.872 #16 Solid 4.02 0.00 20.40 0.00% NAC-4 Notification Appl Ckt 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.230 3.912 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 5.520 0.326 Total Alarm AH Required Total Combined AH Required 5.85 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 7.02 Configure Circuits Print Page ** The SK-5208 and SK-5217 limits alarm current to 95mA per zone. The SK-5208 alarm current includes 10%of system zones in alarm,but in no case less than three zones per UL 864.