Loading...
PFI2014-00041 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT = COMMUNITY DEVELOPMENT Permit#: PF12014-00041 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 07/30/2014 Parcel: SEG952 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Astound Broadband Project Description: Adjacent to 9460 SW Tigard Street.Trench 5'and bore 44'to place(2)-4"&(1)-3"conduits a min of 36" below grade and(1)-17"x 30"vault. SEG 952 Owner: FEES Description Date Amount PFI Permit Fee 07/28/2014 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: PETE ANDERSON 669 GLATT CIRCLE WOODBURN, OR 97071 PHONE: 360-880-9660 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. PermSign tture: licant n(A Signature: (J-r ,V Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12014-00041 Type: Condition Name: Status: Severity: ROW 09-TRAF/NOISE CTRL-WORK HRS Continuing Notice No work will be permitted during the hours of darkness, nor between 9:00 p.m.to 7:00 a.m. Monday through Friday, nor between 9:00 p.m.to 8:00 a.m. Saturday, nor between 9:00 p.m.to 9:00 a.m.Sunday. ROW 04-TRAF CTRL-CONTR RESPON FOR Continuing Notice Traffic control shall be provided for by the contractor in accordance with the City's standard specification and, also, in accordance with a City(job specific)approved traffic control plan.A copy of the approved traffic control plan shall be available at the work area. ROW 10-TRAF CTRL-MIN LANE WIDTH Continuing Notice Minimum travel lane width shall be eleven(11)feet; pedestrian travel shall also be provided for. ROW 01-CUSTOM CONDITION Continuing Notice <Custom Condition goes here> ROW 15-EROSION CTRL REQ Continuing Notice Effective erosion control is required. Erosion control devices must be installed and maintained meeting D.E.Q. requirements.The City may at any time order corrective action and stoppage of work to accomplish effective erosion control. ROW 26-MONUMENT PROTECTION REQ Continuing Notice Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holders expense. ROW 16-REPAIRS-LIKE MATERIALS REQ Continuing Notice Property disturbed by construction activity shall be seeded with a standard grass mix; shrubs,flowers, barkdust,existing signs, pavement markings,mailboxes,etc., shall be reestablished, reinstalled or replaced,with like kind and material. ROW 03-TRAF CTRL-SPECIF(CITY) Not Met Notice The City's standard specification for traffic control is"Manual on Uniform Traffic Control Devices for Streets and Highways", U.S. Dept. of Transportation, F.H.A., 1988 Ed. ROW 05-TRAF CTRL-ROAD CLOSURE Continuing Notice Public roadway shall not be closed to traffic,at any time,without having first obtained written approval from the City Engineer.The permit holder is responsible for provision of timely notification of traffic flow disruptions to area wide Emergency Services(Tigard Police Dept.,Tualatin Fire&Rescue)and to Tri-Met and Tigard School District. ROW 18-UTILITIES PRELOCATION REQ Continuing Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0010 through OAR 952-001-0080. Copies of the rules may be obtained from the Center by calling(503)232-1987. If you have questions about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holders expense. ROW 23-DAILY INSP REPORTS REQ Continuing Notice The permit holders Engineer/Inspector shall submit daily inspection reports,on a weekly basis,to the City's Inspector. (see Developer-Engineer Agreement note#5). ROW 02-PERMIT&PLAN REQ ON SITE Continuing Notice A copy of the permit and all attachments,and a copy of the approved construction plan and all amendments shall be available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's Standards and Specifications and to these General Conditions. Changes to any of the aforesaid must be approved by the City, in advance of work performance. ROW 07-TRAF CTRL-PRIV PROP ACCESS Continuing Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service and if not, shall be cause for work stoppage until effective access is established. ROW 11-TRAF CTRL-CITY CAN MODIFY Continuing Notice The City reserves the right to add to or modify traffic control requirements as may be necessary to effectively control traffic and to assure public safety. ROW 17-DRAINAGE CONTROL REQ Continuing Notice Effective drainage control is required. Drainage shall be controlled within the work site and shall be so routed that adjacent private property, public property and the receiving system is not adversely impacted.The City may,at any time, order corrective action and stoppage of work to accomplish effective drainage control. ROW 27-PROB SOLVING-RESPON PARTY Continuing Notice The permit holder shall provide to the City Inspector, in writing,the names and 24-hour emergency telephone number of two (2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of an emergency.The permit holder shall notify the City Inspector, in writing, of any/all assignment changes. ROW 20-TRENCH-PATCH/SAFETY/LBILITY Continuing Notice A temporary hard-surface patch(Cold mix A.C. or Hot mix A.C. base paving) shall be placed on trenches within roadways at the end of each day's work. No trench, on site or off site,shall be left at any time in an unsafe condition.The permit holder is responsible for and is liable for hazards or damage resulting from the work. ROW 21-REPAIRS REQ-INSPTR OPINION Continuing Notice Work provided for under the permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, in the City Inspectors opinion,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the permit holders expense. ROW 19-UTILITY LOCATIONAL CONFLICT Continuing Notice Contractor must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the permit holders expense. Changes must be approved by the City in advance of work performance. Contractor shall coordinate the work with affected utility agencies. ROW 24-TESTS/REPTS TO VALIDT CLMS Continuing Notice The City's Inspector may, at their discretion, require provision of tests and or reports from the permit holder, permit holder's engineer or contractor to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the permit holder's expense. ROW 25-RELEASE-WAIVER REQ Continuing Notice The permit holder shall provide a copy of a properly executed Release&Waiver document to the City for each ownership disturbed by construction activity, as evidence of disturbance resolution and owner satisfaction. ROW 06-TRAF CTRL-ADVANCE WARNING Continuing Notice Advance warning of imminent traffic disruption shall be provided to the general motoring public by placement of an advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. ROW 29-ESMT/RT OF ENTRY-RESPON Continuing Notice It is the sole responsibility of the permit holder to provide for proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry, or properly executed easements,shall be provided to the City.The City shall in no way be construed to be liable for the permit holder's failure to obtain or provide for proof of right-of-entry or easements. ROW 22-AS-BUILT/ENGR CERTIF REQ Continuing Notice At the end of each year, or an a mutually agreeable yearly date, any entity making changes to its facilities in the public right-of-way shall submit complete"as-built"drawings showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineers certification of installation compliance(form attached). ROW 13-HAZARDS-CERT OF INS Continuing Notice Maintenance of the work area and approach roads is the responsibility of the permit holder.The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards.A copy of the permit holders Certificate of Insurance shall be available at the work area. ROW 08-TRAF CTRL-DEVICES IN PLACE Continuing Notice Traffic control devices,flagpersons,etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. ROW 14-DEBRIS-MATERIALS Continuing Notice The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit.The City may at any time order immediate cleanup and stoppage of work to accomplish cleanup. ROW 12-INSP 24 HR NOTICE REQUIRED Continuing Notice The permit holder or his contractor shall notify the City's inspector Kenny Fisher at 503-816-6146 or email at kenny@tigard-or.gov,twenty-four(24)hours prior to commencing work,twenty-four(24) hours prior to any staged inspection,and after completing work covered by the permit. ROW 28-CONSTR SAFETY-RESPON PARTY Continuing Notice The permit holder shall cause his contractor to provide to the City Inspector, in writing,the name and 24 hr emergency telephone number of a designated"Competent Person"responsible for construction safety as per OR-OSHA, Chap.437, Div. 3 Construction, Subdivision P-Excavations.The contractor shall notify the City Inspector of any/all assignment changes. City of Tigard RECEIVED Application For Work In The Right�br- a CITY OF TIGARD�' PFT PLANNING/ENGINEERING Property Address/Location(s):SW Tigard Ave—410'of SW Grant Ave FOR STAFF USE ONLY Project: WB-3081-2418 S9Q 9�2_2_ 9LhV()( f -rlydACL Right-of-Wer Astound Broadband l75_ Case No.: *Applicants Name: , 669 Glatt Circe Application Accepted— 7:-2.,99 By:f4B— 1 Address: Application Reviewed:l By: Ci /State:Woodburn, OR Zi 97071 t so ry p Pete Anderson Application Fee Due: 300 Primary Contact: "� Applicant Notified: �LA A-V- Phone:(360)880-9660 Fax: eceipt No.: �C✓ Email:Panderson@wavebroadband.com reciym11X44 vrni+-13� 14 REQUIRED SUBMITTAL Contractor's Name:TBD INFORMATION CCB# Expiration: . Application form,completed and signed Address: • Submit one (1) copy of scaled sketch of City/State: Zip: the proposed work to be done Phone: Fax: • Submit one (1) copy of traffic control Email: plan Professional Engineered Plans are required Plans By:K&B Technical Solutions Attn: Jack Nygard for: Address:PO Box 2529 • Street Widening City/State:Clackamas, OR Zip:97015 • Subdivision Infrastructure Phone:( ) Fax: 503 650-6041 (503)650-7390 • Main utility line extension Ems.Jack_Nygard@kbmail.net Rev.6/23/2013 Izurpin\masters\land use applications\row app.d«x Description of work:Astound Broadband proposes to trench 5'and bore 44'to place (2)-4"&(1)4"conduits a min of 36" below grade and (1)-17"x30"vault. Estimated value of work(within the public right-of-way): $ Is work related to a LAND-USE DECISION? YES ❑ NOF-01 If so, please specify (MLP,SDR,SUB,etc.)case#: Is the work related to a BUILDING PERMIT? YES NOF If so, please specify(BUILDING PERMIT)case#: Signature of Applicant/Permittee:i4A" jWJiL_u_k A/r jw-fl ac{Fe4e-Ahkr.5G,I Date:7/23/14 el 61V FU Print Name:Pete Anderson Title:Construction Manager City of Tigard 1 13125 SXV Hall Blvd.,Tigard,OR 97223 1 503-718-2464 1 www.tigard-or.gov M61tifink * 6 Bay OTN Cabinet Applications: An above ground housing to shelter Environmentally sensitive equipment from Rain, sleet, snow,dust, driving wind,hail, Corrosion,and vandalism. Specifications Dimensions: 106 %s"W x36 %x"D x 62 %z"H(270.5cm x 92.7cm x 158.75cm) Weight: 1200 Pounds(544.3 kg) Construction: Main Body: 1/8"Marine Grade Aluminum 5052-H32 Hardware: Type 304 Stainless Steel Finish: Polyester Powder Coated Racks: 3/16" Steel E.I.A./T.I.A. spacing(10-32 threads) Doors: 3 point latch for maximum security Cable Entrance Compartment: Four slack storage brackets with heavy duty Velcro® straps to secure cables Two entry holes for bringing cables into the main cabinet Powering Compartment: 100 Amp Service 12,000 BTU Air conditioner with integrated heater 60 Amp Generator Hook-up with a manual transfer switch AC Load Center: 4 GFI Outlets; 120V, 15 Amp 1 240V, 30 Amp Outlet Separate battery compartment Main Cabinet: 3 19"-23"Adjustable width racks, also adjustable front to rear position(43"tall) 3 19"23"Adjustable width racks,swing out for ease of rear equipment access(40"tall) 249"of total inches of rack space(142 RU) 4, 15 Watt Shatter-shield light fixtures Grounding All components are grounded to the main copper bus bar Mounting: Stainless steel frame structure is provided to be placed in wet concrete for mounting I 109.38 51.75 25.00 33.50 OPENM OPENING OPENING SLACK STORAGE ; •j I i I CAMET MAIN CHAMBER WITH A/C A POWER I 1 1 I FRONT/REAR ACCESSAND PACK SYS 1 E CABINET _ — -- — — ' — RACK SYSSYSTEMTEM I el • o o • • !�'s • rCAPACrrY TO HOLD 23 RACK UNITS. 11-13 54.0030.1 11.13 12.75 106.38 36.00 CABINET BATTERY TRAY J HEIGHT FRONT VIEW STORAGE CHAFER 44.00 END VIEW o • • • 8 A/C RECEPTACLE vi N BREAKER a e o e PANEL AIR CONDITIONER 48.00 20.00 10.00 GENERATOR TRANMOUNTING PATTERN SWITCH MAIN BREAKER E._T.. T_1 rT T-1 s s s • - - GENERATOR _ _ INLET 21.63 21,63 CONNECTOR AVAILABLE AVAMABLE BATTERY BATTERY SPACE SPACE BATTERY CHAMBER FRONT VIEW - 29.63 GROUND BAR AVAMABLE BATTERY SPACE 10.50 A/C & POWER CABINET LAYOUT 24.50 EXTENDED BATTERY CHAMBER SIDE VIEW Mesiti'Unk-N 582 Ternes Avenue Elyria,OH 44035 Phone:(440)366-6966 Fax: (440)-366-6802 e-mail:engsupport@multilinkbuilt4u.com Page 80 2011 Edition 5.3 Two-Lane, Two-Way Roads Shoulder Work w/ Minor Road Encroachment Diag. 300 Use this detail for non-freeway work which extends into a travel lane and maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane can not be maintained, or when traffic can not safely pass by in both lanes simultaneously, use the appropriate lane closure diagrams—for example, Diagrams 310 through 350. A lane closure may be appropriate for conditions such as high traffic volumes, high speeds, and inadequate approach sight distance to the work space, or heavy equipment adjacent to the travel lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3 — Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Cones shall be placed along the entire length of the work space. If a protection vehicle is used and work is in place one hour or less, the taper and tangent devices may be omitted. 4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there is limited sight distance, consider placing cones or tubular markers on centerline. 5. An arrow board in caution mode or truck-mounted PCMS with "SHOULDER WORK" or other appropriate message may be used for higher visibility. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs Buffer Speed A B c Space 20 50 25 100 100 100 75 30 100 35 40 350 350 350 125 150 45 180 50 500 500 500 210 55 250 Chapter 5 December 2011 I� 2011 Edition Page 81 Shoulder Work w/ Minor Road Encroachment Diag. 300 ROAD WORK to AHEAD • Initial Warning A • Sign • • • (OptionaQ • gul • Protection Vehicle w/TMA(both Optional) See Chapter 4 - • Buffer 10' minimum • U3 • A ROAD M NARROWS • (Optional) B ROAD � WORK AHEAD Initial Warning Sign December 2011 Chapter 5 i \ N NOTES: \ 1. ALL WORK AREAS TO BE \ RESTORED TO LIKE OR BETTER w E CONDITION. \ 2.ALL OTHER UTILITIES ARE BASED \ \ OFF EXISTING LOCATES OR UTILITY S STRUCTURES. \ AWaaOepMdby0nO«'nt7w�pl 'Plari 110110e 3. IT IS THE CONSTRUCTION \ c.nt..Ttlea.w w«Lw rt�llrers>� \ act,actor„a,,,y,t�oot,aaaY,,,s,�,.ew„ CONTRACTORS RESPONSIBILITY TOS \ Owl-- the Pkia TO CALL FOR LOCATES BEFORE \ \ GN Ner11160w:MlYtbOW)2u•,rrTeret,l DIGGING. \ NT AVF \ \ � \ 4. BORE/DRILL SYM. - ` 5. TRENCH SYMBOLOGY- 0A YMBOLOGY-oo \ 6. REMOVE & REPLACE SYM. -\\ L J T FROM EOP FROM ROW 3'\ TRENCH AND PLACE LO &(1)-3-CONDUITS A MIN OF 36”BELOW GRADDE ®'25 7 BEGIN UNDERGROUND CONSTRUCTION IN CITY OF TIGARD ROW UNIMPROVED AREAS — BORE AND PLACE(2)-4"&(l)-3- (TRENCHING) CONDUITS A MIN OF 36"BELOW GRADE ,z"NATIVE TOP SOIL IF Contact: Pete Anderson TOP SOIL EXISTED \ 3, Title: Construction Manager PRIOR TO EXCAVATION w \ \ Mobile-(360)880-9660 \ Email- panderson@wavebroadband.com / .GRANULAR' ' / R k/ cable I Internet I pone OR 95%COMPACTION ' NATIVE 300 7 BACKFILL BACKFILL 3, \ \ astound. ' = 5 ;V 1 0'FROM WATER/ �,k '^ 3, VFROM ROW � 669 Glatt CITCIe PROPOSED VAULT 2'FROM FOC \ FOR POWER �� \ Woodburn,OR 97071 REMOVE&REPLACE(1)-5'X5' .50 \ - O PIPE ZONE FLAG OF SIDEWALK TRENCH AND PLACE(2}4"&(l)-2- i,, 40' PO BOX 2529 CONDUITS A MIN OF 36"BELOW GRADE \ CLACKAMAS,OR 97015 Design By:K&B(503)650-6041 / EXIT CITY OF TIGARD ROW \ Email:kbeng@atLnet HARD SURFACE / / / \ SITE ADDRESS: BO�-� T T WAVE SEPROPO EQUIPMENT 253TA VAULT FOR 5 TGSyy \ SW Tigard Ave NCge3' Portland, OR 97223 ,3' \ 2S1 W02 REV. DATE DESCRIPTION APPROVED % GATE 1 7122/14 CITY OF TIGARD PERMIT DRAWING 'GRANULAR;/,' 95%COMPACTION OR / NATIVE , 9460 SCALE: PROJECT NUMBER;- 1"=20' UMBER:1"=20' PIPE ZONE O SHEET NUMBER TITLE: FIBER ENHANCEMENT i PERMIT DRAWING FILE NAME: SHEET 1 OF 1 WB-3081-2418 i