Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT 11 COMMUNITY DEVELOPMENT Permit#: MEC201400385 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/24/2014 Parcel: 2S102AC00700 Jurisdiction: Tigard Site address: 12540 SW MAIN ST 200 Project: BMDA Subdivision: BURNHAM TRACT Lot: 1 Project Description: Replacing RTU with a push-pull unit on existing curb. Contractor: HVAC INC Owner: DOLAN&CO LLC 5188 SE INTERNATIONAL WAY BY FLORENCE T DOLAN MILWAUKIE, OR 97222 4523 NE DAVIS ST PORTLAND, OR 97213 PHONE: 503-462-4822 PHONE: FAX: 503-462-6555 FEES Specifics:, Description Date Amount Type of Use: COM Permit Fee 07/24/2014 $221.26 Class of Work: ALT Type of Const: VB Plan Review 07/24/2014 $55.32 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 07/24/2014 $26.55 Stories: Info Process/Archiving-Sm$0.50(up to 07/24/2014 $3.00 11x17) Project Valuation: $5,500.00 Fuel Air Handlers Fuel Types: Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $306.13 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is no tarted within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the r•I=, adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. •u ma' btain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.3 Issued By: / S Permittee Signature: Call 503.6 •.•4 :00 a.m.for the next available inspection d:to This permit card shall be kept in a conspicuous place on the job site until comple••n of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application wiz 014 u l( I I sl ()NIA IN City of Tigard Received Permit No.: (2Go'td/L(—(}p ; 9- 13125 SW Hall Blvd.,Tigard,OR 97 J4EO Phone: 503.718.2439 Fax: 503.598 D I Plan ie ` Inspection Line: 503.639.4175 �� A K U P� Date Ready/By.. Internet: www.ti and-or. ov Supplemental See Pent l for g B ,uL 2 4 2014 Date : riMSupplemental Information TYPE OF WO Cii COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alter I1 performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: llll mechanical materials,equipment,labor,overhead,and profit. Value:$$5,550. CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. 1_ Total JOB SITE INFORMATION AND LOCATION Heating/cooliog: Air conditioning Job site address:12540 SW Main St. (requires site plan showing placement) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000 BTU(ducts/vents) 46.75 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: /›ADD Project name:Dolan Commercial Building Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. _ 46.75 Subdivision: Lot no.: Flue/vent for any of above 23.32 Other: 23.32 _ Tax map/parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 Gas fireplace/insert 33.39 Push/pull rooftop unit -same curb Flue vent for water heater or gas fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert _23.32 ❑ PROPERTY OWNER ❑ TENANT Chimney/liner/flue/vent 23.32 Other: 23.32 Name:Dan Dolan Environmental exhaust and ventilation: Range hood/other kitchen Address: equipment 33.39 • City/State/ZIP: Clothes dryer exhaust 33.39 Single-duct exhaust(bathrooms, Phone:( ) Fax:( ) toilet compartments,utility rooms) 23.32 ❑ APPLICANT ❑ CONTACT PERSON Attic/crawlspace fans 23.32 Business name:HVAC,Inc. Other: 23.32 Fuel piping: Contact name:Jody DePew $14.15 for first four;$4.03 for each additional Address:5188 SE Internaitonal Way Furnace,etc. Gas heat pump City/State/ZIP:Milwaukie,OR 97222 Wall/suspended/unit heater Phone:(503)462-4822 Fax::(503)462-6555 Water heater Fireplace E-mail:jodyd @hvacincorp.com Range CONTRACTOR Barbecue Business name:HVAC,Inc. Clothes dryer(gas) Other: Address: MECHANICAL PERMIT FEES* City/State/ZIP: Subtotal Minimum permit fee($90.00) Phone:( ) Fax:( ) Plan review(25%of permit fee) CCB lie.:50897 State surcharge(12%of permit fee) TOTAL PERMIT FEE Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Jody DePew I Date:7/24/14 ' Fee methodology set by Tri-County Building Industry Service Board 1:\Building\Permits\MEC-PermitApp. 03/07/12 440-4617T(I1/02/COM/WEB) Er! Building Division Over-The-Counter (OTC) Mechanical Permit TIGARD Check List Project Description: 1R APPLICATION SPECIFIC INFORMATION GENERAL INFORMATION *Class of Work: &L Occupancy Group: Type of Construction: *Type of Use: ( j(k Oregon Specialty Code: Number of Stories: FUEL FURNACES Type: Furnace< 100K BTU Furnaces>= 100K BTU Gas Pressure: Roof Top Unit(RTU) i Tons Floor Furnaces Unit Heaters Vents without Appliances Air Conditioning Heat Pump AIR HANDLERS HOODS Units<= 10000 cfm Type 1 Hood Type 2 Hood Units> 10000 cfm Grease Duct 1 Hour Shaft Fire Wrap APPLIANCES Boiler(BTUs) Vent Fans Gas Line Solid Fuel Fireplace/ Clothes Dryers Gas Outlets Woodstove Duct Work Gas Fireplace Fire/Smoke Dampers Other Mechanical Units—Describe: Total Project Valuation: $ `��rj =) FEES DUE $ 2 , Mechanical Permit Fee $ Tj"S, ! Plan Review $ _, v. 12%State Surcharge $ Info Proc/Arch,Lg(over 11x17$2.00) $ 636o Info Proc/Arch,Sm(up to 11x17$0.50) $ Misc.Admin Fee $ Hourly Rate Fee $ Hourly Rate State Surcharge $ _ Other: $ Other: Building Staff: Date/Time: $ TOTAL FEES DUE *0PTIONSk TYPE OF USE COM=commercial;CMS=commercial manufactured struc111Ye. CLASS OF WORK ACS=accessory;ADD=addition;ALT=alteration;FND=foundation;DEM=demo; FND=foundation;FPS=fire protection system;NEW=new;OTR=other(use for fences,decks,retaining walls,signs,awnings or canopies); REP=repair. I:1Building\FormslOTC-MEC.docx 01/13/2011 D0(a/A CO ViA ei&cd -'Jab 56,6,2(e Physical data — 48TJ004-00 EIVED cie,_ JUL 24 2014 W e UNIT SIZE 004EiF 0050/E/F =a"r,. 006D/E/F 007D/E/F NOMINAL CAPACITY(tons) 3 4 r` 5 6 OPERATING WEIGHT(lb) Unit AI/AI' 460 470 490 565 AI/Cu" 465 476 _492_, 576 Cu/Cu• 468 482 f 505 587 Economizer 34 34 i 34. i-.� . 34 Roof Curb 115 115 f• 115 '.3"( 115 COMPRESSOR Hermetic 011 (oz) 50 I 50 I 50 I 54 REFRIGERANT TYPE R-22 Operating Charge (1b-oz) Circuit 1 3-6 4-11 5-13 7-10 Circuit 2 — — — — CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fins Total Face Area (sq ft) 17.36 I 11 39 13.19 I 10 42 CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4000 Quantlty.,.Diameter(In.) 1 ..22.0 1 22 0 1 ..22.0 1. 22.0 Motor Hp...Rpm '/4..1100 x/.. 1100 1/4 1100 1/4...1100 Watts Input(Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins, Acutrol'" Feed Device Rows...Fins/in. 2...15 2...15 3 15 4 15 Total Face Area(sq ft) 4 17 5.5 I 5 5 I 5 5 EVAPORATOR FAN Centrifugal Type - Quantlty...SIze(In.) Std 1 10 x 10 1 ..10 x 10 1 11 x 10 1 ..10 x 10 Alt 1 .10 x 10 1. .10 x 10 1 ..10x 10 Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — Nominal Cfm 1200 1600 2000 2400 Motor Hp Std — — — — Alt lt Maximum Continuous Bhp Std 34 75 1 20 2 40 al Alt 100 100 180 — Motor Frame Size Std 48 48 48 56 Alt 48 48 48 — Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt — — — — Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max (in.) Std — — — 2 8/3 8 Alt 1 9/2.9 1.9/2 9 2.4/3 4 — Nominal Motor Shaft Diameter(in.) Std 1/2 1 1/2 5/8 Alt 1/2 '/z '/2 — Fan Pulley Pitch Diameter(In.) Sid — — — 4 5 Alt 45 40 45 — Nominal Fan Shaft Diameter(in.) — — — — Belt, Quantity...Type...Length (in.) Std — — — 1 A..40 Alt 1...A.34 1 ..A. 34 1 A. .34 — Pulley Center Line Distance(in.) Std — — — 14.7-15 5 Alt 10.0-12.4 10.0-12.4 • 14.7-15 5 — Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — Movable Pulley Maximum Full Turns Std — — — 5 FrOm Closed Factory Setting Position St 05:TIG A R^ 5 5 3 RE IIIII�-D FORtODE COMPLIAN 3 — Factory Speed Setting (rpm) tfY — 1225 t 975 1060 Fan Shaft Diameter at Pulley(In.)Approvals '/2 1/2 1/2 1/2 OTC: ( v, (Table continued on next page) Permit#a f iE C ah,'1 —CX) EsS • Address: ' ,ai[v S M,3,xi SI- sc.' ,11uoj suite* .• By: f Dates \< 4,___ 410 • OFFICE COPY 6 VIBRATION PAD (4) PLATED #10 TEK (4) PLATED #10 TEK X 3/4" SCREWS X 3/4" SCREWS 16 GA X 6" SEISMIC CLIP f EACH SIDE (TOTAL 4) NAILER STRIP :1�' SEE ARCH. DWGS. FOR FLASHING. UNIT CURB (1)- -------` . 1 1/2" RIGID CANT STRIP (BY OTHERS) 14" INSULATION i ATTACHMENT OF CURB TO ,Iw l, STRUCTURE BY OTHERS I •' • . ••nom•••••••• •• bk.ameleng0.1,4■1_0■AMAkiblimi% PT LEVELER ''' --, l ROOF OPENING (E) JOIST ALL STRUCTURAL AND CURB LEVELING BY OTHERS. All dro*ings prepared by HVAC INC ore the enclusive property of HVAC INC and, unless other*ise agreed in *riling. HyAC INC RELEASED FOR sholl be deemed the author of them and DETAILsholl retain all common lo*, slotutory and PROJ other reserved rights. in oddlion to the MGR copyright. Any use thereof *ithoul the express 1986 2012 Written consent of HVAC INC is prohibited. LE NAME .7‘ 0�0I cv C r � )R O O F C U R B DETAIL PROJECT MANAGER � �1 A`V�`` HVAC =, I ENGINEER r Inc.pornted 2 N E C \ \°pe 198 DATE. I I/28/2012 5168 INTERNATIONAL WAY MILWAUKIE OR 97222 FAX:. (503)462-6555 SHEET. for PHONE: (503)462-4822 M D 8 7 OR CCB# 50897 \ ` l YWA HVACI ••125J6 A • .rx q� : :. gn u._ F itto' o-� . sar i i••1.- .. „tY , J f x_Ar. Yy.• {I14 Yl JYC4 .tY: tip- b -• •rte . ,f V .plh ,n,� aih x y.. _ 's t L # emu" I .�4• Sys b�. #.... ,• .. , . may « "•` }' '4 r r fc ' w ;� 3 a N : T. Ji*v F 4 Y T .^S +4. QuY(jai+�:?J09C�31kkR+rpbrhl3.1•-w l st�l }t�I ,.• Gogle ea rt feet 90 4 meters 30 * j_,i/Iii' Unit Report For 5T Project: -Untitledl 07/07/2014 Prepared By Airefco, Inc. 01:45PM Unit Parameters Dimensions (ft. in.)&Weight(lb.)*** Unit Model: 48TCDA06A2A5-0A0A0 Unit Length 6' 2.375" Unit Size: 06(5 Tons) Unit Width' 3' 8" Volts-Phase-Hertz' 208-3-60 Unit Height' 2' 9.375" Heating Type Gas • Total Operating Weight _ 579 lb Duct Cfg: ....Vertical Supply/Vertical Return Low Heat ••• Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size 1/2 Condensate Drain Line Size:........ 3/4 Return Air Filter Type* _. Throwaway Return Air Filter Quantity' ....... 2 Return Air Filter Size' 16 x 25 x 2 Unit Configuration Medium Static Option Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA06A2A5-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option None None Packaged Rooftop Builder 1.39j Page 1 of 6 • 3. • Certified Drawing for 5T Project:—Untdled1 07/07/2014 Prepared By:Airefco,Inc. O1:45PM W1ES: 1.1'er [AI[YY LL IKN[05N IN0 NIT J t 0 FN10 r1ES.0.::,.•• lyya wiA lln , • NU r ai„ ' •mnAs ar 1' 'FTC'.I01Nt 11 S1t 2 6 CCYI[t CS OtAYlll ANC-NS WIT IC Ill EMETICS bl![i INII I)Ill A 1 SID•1151 III FIELD MINI SUPPLY NlE 1. 11121100 OF 1n FLOW IIIC-AIC 11!t 1 Tlt [0099 [511 t i'INl PIS INS.NMII 1•011001 N•C*NT InSll '[)111 _C I lie ISII Dn 1•01[ACCESS PLUS 0 III•IISI III mu COMM.DnIK 10.E 7181 11 SIP-u llr C0YNINIE INII f Irr N[cgltrnq 11-lla YIItN loan r .—1 •0 i 11•1151 111 PNEI SUPPLY 11011-00I IDlll 1.11.1 I --I . 14061 rlll[t ACCESS PANEL nII-111-143[CWT I rp0.'1C1Sl Cqr. + nEff NOl[S ICN 11[1 Fq NE PAIL c NEI _ I C 14411 1K1,IIMIt 11Dg1 COIL r I -- _ _ i 1(1111112(1 143 II2f1IlIAICI 410133 PNEI t 1t• ACC. UP 111.2 , , -� N.. -�{l 10-100 I II• tR' 7n 1/8•122.21 C �_ II '1 Lan ` ((Ill 511•IIP.II) POW[t I I/I'[D/.11 ;•IO. -∎ilk-1>ai1/�l• N •• 9[1111 In f IElY11 lel 111111 '' ( `I 11 I•• Illll l/t'EFT W 1 9999•x1.11 BACK If111 I O 1 11119 1 140 OIII 3.3.SA!(10 Hpa01:0 CµT - • SFLECT E1TIK1 111'q 195' CYII 1• - • I CNI[dR 1-I1C •r F01 INEI,NIt1IN N VISE SIZE DIIN cI NAZI IARPN SVPII !t-112 11.116 loll 110011[VI;RIN W CYID mii 11.1a 1 1 E 11 IIIJI 11111 fINPL, 11311 I I I It 15.1/I 131311 bill -- 1- • 1 111 In❑ UNI inn s[IK[.CNNI V 8 r . 11 ;all. —p n-vi Lan MC -1.1 NqD •^11-IIZ I TOR 14111 I In I0I1E Intl MSI A IIEI lICT11CAl IIXg1[C0141101 CONE NCI COlrla 0.1 IYOOOR ILq[1 s COII II II (is PANEL ACCESS I COYI[INC.O[ ILICI NS11 _ ® I _ - Sul YPl IaW IlpiAlTl[0 - , I11 �KIpAi �l I-1n 119 I �T[1C II+SI0.canElrzltE Inn IrnAUeo (I A1Dn 9119 sums ul I¢T giLCi II I W I DIKONECi I` ',r, `. I -- Qi -1/IS 0 �Rf= = � [�H' ',�N• i= �1 1931 = - �1.1 •• 1.10 1-1/4 N'bLA 1-111 1-511 1 1551 I-I/S 50'1/1 11151 1111] 11111 A11-3/4 all RIII ❑SDI Ilan 91-1/1 111111 Iltl l NIp[n1E It1/S IFII[r MP 17!11 q LEFT FRONT MP"4 411 1[1001 RIGHT mu Mg MMWOU 18TC 04-07 SINGLE ZONE ELECTRICAL 48TM500993 15`•0 1 a x 11-24-08 09-29-08 COOLING WITH GAS HEAT Packaged Rooftop Builder 1.39j Page 2 of 6 Certified Drawing for 5T Project:—Untitled1 07/07/2014 Prepared By Airefco,Inc. 01 45PM — 740 _ tF[MIOLR I[S tWUt.n� 110 I`2 COINft - C011f( C011E1 ISAlI C.6. R1/11 C11tlEt r41r114r14441rm a44n. e1111r4sr rrw111 1 r¢In1�1scu�1tt� <. 1111 8141 R111i III RI01r III R141r(CI 1[IW 101 lit. K. LIS. 16. (IL-I. LIS. 16. LIS. I. I I I 414[-114 411 211 111 54 115 SI 131 II 111 51 16(1111 tl 15141 11 111(4111 411-113 III 244 121 54 III 13 113 II 121 19 11(1111 21(5141 12 14321 517.111 511 354 111 16 141 61 154 II III 12 St 1111]23 15141 11 111(1111 517411 152-266 156 I III 11 III 14 III 11 Jt Inn 2115141 20 111 11111 CORNER A CORNER B 0 • Ilflftp 22"`11111 •VI, l 'il\V®1111 CORNER 0 CORNER C CP • 1h14'H tfl00 _(• 1 �: : 000 I FRONT war mica° 45TC 04.01 SINGLE ZONE ELECTRICAL I 48TM500993 2R 2 11-24-08 09-29-08 COOLING}ITN GAS NEAT i I5.0 Packaged Rooftop Builder 1.39j Page 3 of 6 • Performance Summary For 5T Project: —Untitledl 07/07/2014 Prepared By:Airefco, Inc. 01:45PM, Part Number:48TCDA06A2A5-0A0A0 ARI SEER — _..___ 13.00 Base Unit Dimensions Unit Length 74.4 in Unit Width' 44.0 in Unit Height _ — —_.__._.....____..._____— 33.4 in Operating Weight Base Unit Weight. _ 569 lb Medium Static Option. _ — _ 10 lb Total Operating Weight. 579 lb Unit Unit Voltage-Phase-Hertz' _ 208-3-60 Air Discharge __._.— ____..._......._....—_._.._.... ___.Vertical Fan Drive Type _......._...._ _..._._........._ � ...._..---__.._.....___....�__.._...._ Belt Actual Airflow. _. ...._ 2000 CFM Site Altitude- ____......__. 0 ft Cooling Performance Condenser Entering Air DB. _ _ -_ 95.0 F Evaporator Entering Air DB —_..____.__..................80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy' 31.44 BTU/lb Evaporator Leaving Air DB. — 57.9 F Evaporator Leaving Air WB —___ 57.3 F Evaporator Leaving Air Enthalpy _... _ _ — _ 24.56 BTU/lb Gross Cooling Capacity 61.90 MBH Gross Sensible Capacity. _. _ 47.70 MBH Compressor Power Input:._ _ _ 4.43 kW Coil Bypass Factor __...___._ _...__._. _ 0.055 Heating Performance Heating Airflow _ ._.___ _._ _ 2000 CFM Entering Air Temp- _ W _ 70.0 F Leaving Air Temp 97.3 F Gas Input Capacity. _ — 72.0 MBH Gas Heating Capacity. 59.00 MBH Temperature Rise — ___.._____— —_..__...............___._— __.__ _ 27.3 F Supply Fan External Static Pressure' 0.50 in wg Options/Accessories Static Pressure Economizer _ _ _ 0.12 in wg Total External Static. _.._ — — _ 0.62 in wg Fan RPM. __ 1251 Fan Power 1.21 BHP NOTE _ .— — _ Selected IFM RPM Range: 1035-1466 Electrical Data Voltage Range. _. 187-253 Compressor#1 RLA• 15.6 Compressor#1 LRA- _ _ 110 Indoor Fan Motor Type' _ _._.___..___ _ MED Indoor Fan Motor FLA' 6.9 Combustion Fan Motor FLA(ea)' . . _ _ 0.48 Power Supply MCA. 28 Power Supply MOCP(Fuse or HACR) _...... ..._ _ — _ 40 Packaged Rooftop Builder 1.39j Page 4 of 6 i Performance Summary For 5T Project: -Untitled1 07/07/2014 Prepared By:Airefco, Inc. 01:45PM Min. Unit Disconnect FLA. _ _ 28 Min. Unit Disconnect LRA Electrical Convenience Outlet -.___._ None Outdoor Fan[Qty/FLA(ea)]' 1/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 87.5 87.2 84.0 125 Hz 82.7 79.6 82.2 250 Hz 75.6 66.6 76.3 500 Hz 71.3 63.9 74.8 1000 Hz 67.9 63.2 72.5 2000 Hz 62.2 57.3 68.8 4000 Hz 64.0 53.2 65.6 8000 Hz 59.6 45.8 61.8 A-Weighted 74.7 69.3 78.0 Advanced Acoustics I :. . --► Ni Ili i 104 Lkli `0 ■ Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground:.._ 5.7 ft 4. Height of obstruction- 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 87.2 Lw B 57.8,66.1 67.7 71.6 72.5 70.0 66.6 60.7 77.7 LwA C 51.6.49.8 43.9 42.4 40.1 36.4 33.2 29.4 54.8 Lp D 25.4 33.7 35.3 39.2 40.1 37.6_34.2 28.3 45.3 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A-Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp Packaged Rooftop Builder 1.39j Page 5 of 6 1 Performance Summary For 5T Project: -Untitledl 07/07/2014 Prepared By:Airefco, Inc. 01:45PM D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve w N 1414F9A s\ \1d:CR4 \l; ,,,, 1s , 1107RFM \ 16 \ d,14- _ \ c 12 \ N 9�RPId \\ \.038 p vi 1A - \ N d ) 76 7CnFPId \ \ 4 CO CO 116 09 12 5 1.8 21 24 27 A diow(CFM-µ usa ds) RPM=1251 BHP=121 Maximum RPM=1466 Maximum BHP=2.90 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.39j Page 6 of 6 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12540 SW MAIN ST 200, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2014-00385 Jeff Grove Violation Summary: Inspector Contractor