Permit 1y CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 11 COMMUNITY DEVELOPMENT Permit#: FPS2014-00116 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/24/2014 Parcel: 25101 DA00105 Jurisdiction: Tigard Site address: 13009 SW 68TH PKWY A Project: Homestead Studio Suites Subdivision: VARNS ACRES Lot: 9 Project Description: Replacing fire alarm panel. (1)fire alarm panel for buildings A,B,and C. Contractor: FIRE SYSTEMS WEST INC Owner: BRE/HV PROPERTIES LLC 600 SE MARITIME AVE#300 TAX DEPTARTMENT VANCOUVER,WA 98661 EXTENDED STAY HOTELS OP BOX 49550 CHARLOTTE, NC 28277 PHONE: 360-693-9906 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-COM 07/24/2014 $156.00 12%State Surcharge-Building 07/24/2014 $18.72 Type of Use: COM Plan Review-Fire Life Safety-COM 07/24/2014 $62.40 Class of Work: ALT Type of Const: IIB Info Process/Archiving-Sm$0.50(up to 07/24/2014 $3.00 Occupancy Grp: R-1 Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Yes Alarm Type: Automatic Pull Station Required: Smoke Detectors Req: Yes Battery Calcs Provided: No Cut Sheets Required: Yes Total $240.12 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $7,285.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notific. • - -r. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct• -stions to OU • b ,g 503.232.1987 or 1.800.332.2344. Issue. By: / Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application �`'� Fire Protection System �al� ht11z OFFICE LSI. ON1,1 R . City of Tigard ��A r� '��t Date/B : / /� Permit No.: =� a v�I • 13125 SW Hall Blvd.,Tigard,OR 9 to y�� CPI g Plan Review M f Other Permit: Phone: 503.718.2439 Fax: 503.598. \``\\� iO Received e eiv : � TIGARD Inspection Line: 503.639.4175 Jv t �>` ^® Date Ready/:y: etas: ® See Paget for Internet: www.tigard-or.gov (v�( �ut� Notified/Method: 7 �����r ,� ' Supplemental Information• .t C�c •." .y�ja�7ri ifs ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all [ irddition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ommercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: Mopq, S(o 6' i �e" .,14, New dwelling area: square feet City/State/ZIP: Tg ={ Q e t�72 3 J Garage/carport area: square feet Suite/bldg./apt.no.: A fa L Project name: / '�ul 5 i Covered porch area: square feet Cross street/direction_slto job site: �1 Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: f Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: a and the profit for the ,, �t equipment,materials,labor,overhead,a e pr t ?�� U 70,/&,,,-, .1!;10.4) : , ;�., TA,,„,„,,, work indicated on this application. r Se.R-Q 0Z C V'c of .k/'Q Pt(.Ae- ■ P A -- Valuation: $ 728 TGf bl_.t frAlll.l 7¢1 r,i cvdd, t` /at -(! 4Pk Existing building area: square feet ?AB,/i�. 4'� f_` New building area: square feet ❑ PROPERT'e OWNER 1 ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: PLICANT ❑ CONTACT PERSON NOTICE Business name: le , - i "9 All contractors and subcontractors are required to be Contact name: '( 1. �_kr:11-K-f(./ licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: enggp se 44A0t16"1„ Ave f4 35 ) jurisdiction in which work is being performed. If the City/State/ZIP: applicant is exempt from licensing,the following reasons Aiv'Cf�UI/Pi/� (�� �8(O�o/ apply: Phone:(3tjo ) -7-7(,. ?6�, 5 Fax: :( ) E-mail: iitarit_Sa,+Sre_sySitotS (.9e-St CONTRACTOR BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: c r .S,S.k„p-I,,Q (�,Q,�S - Permit fee: Address: —`t _�"�� State surcharge(12%of permit fee): City/State/ZIP: FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application.) CCB lie.: 49732_ Total permit fees: _Authorized signature: Amount received: This permit application expires if a permit is not obtained Print name: k SGLN[ •J Date: 7?I within 180 days after it has been accepted as complete. ( //2�r Fee methodology set by Tii-County Building Industry Service Board. 1:,Building\Permits\FPS-PernitApp.doc Rev 01/05/2012 440-4613T(11/02/C064 WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ❑ 1-10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: _ Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ \Vet ❑ l)r� Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I- Hood Fire Suppression System _ Hood Project Valuation: $ C.) Fire Alarm -72.-A65 Submittal shall Battery Calculations ❑ Yes include: Individual Component ErYes Cut Sheets Fire Alarm Project Valuation: $ 7 2$5 D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B &C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. C:\Users\marks\Downloads\FPS-PennitApp(1).doc Rev 01/05/2012 2 HOMESTEAD STUDIO SUITES #9692 13009 SW 68TH PARKWAY RECEIVED TIGARD, OR 97223 JUL 8 2014 CITY OF TIGARD BUILDING DIVISION FIRE ALARM DATASHEETS Prepared by Fire Systems West, Inc. - Phone 360.693.9906 CITY OF TIGARD REVIEWED FOR CODE COMPLIANC* Approved: ( t� OTC: ( Permit#: moo t4-eC7 Address: aO - = f� �✓ smite # . By: Date: 7_� I t� tigCi 3 OFFICE COPY R 'gam i . fix, 1 n -._ ,,„r- 1,, ig IA ... —I ',.... . .. . •mac i. i, I 1' , . t , 1� c o _ s dS ntF . . - _ v , F ® T �.O - 13009 SW'68th Pkwy igarOR97223.UA • ` 4 a' as n a o" w N. i. .,z I. . o I, y' }. J , -,..• i� _ SCOPE OF WORK:Replacement of FACP panel with new panel. Additng smoke detector above panel. Model 5208 Q Fire Alarm Control Panel with 4 Digital Communicator 4 J { _ ., The Fire Alarm Control Designed to Grow with eon` Your Systems Needs, Without The Growing Pains. a; The SK-5208 is a microprocessor based control panel with built-in UL .r listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for =-.F.tiiita modules can be mounted remotely Daylight Saving Time from the main control panel • Clock source setting options for 50 •r • ••• i • Event History Buffer(150 events) Hz, 60 Hz, or internal (uses the • with date/time stamp panel's internal clock) 7 `" • All zones are compatible with 2-or Specifications 4-wire detectors 1 • 8 selectable/programmable output Operating Voltage: 24 VDC „a. patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: ic.,r4, relays Height: 24.75" (62.9 cm) _--.::• • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16"(8.73 cm) enhanced verification mode features with 5/8" protruding SK-5208 that can help minimize false alarms Overall Dimensions: • Programmable from the built-in Height: 26-3/8" (67 cm) SKSS Downloading Software •control panel touchpad, remote Width: 17-3/16" (43.66 cm) • annunciator, or Windows®SKSS Total Depth: 4" (10.16 cm) Plex-2 Door Option downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) • UL Listed up/downloading with Windows® Humidity: 10- 93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) SILENT while providing single button • 7181 Fire Zone Converter KNIGHT operation of the reset and silence • 5220 Direct Connect Module Ifiti functions • 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module by Honeywell Model 5208 ittitil Fire Alarm Control Panel with Digital Communicator t Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 �, Direct Connect For On-Site Programming 2 Class A(Style D) ® 1 p;,— or Class B (Style B)4 : i'` ,i �i �,Programmable Initiation Circuits ... E Form C Relays 8 Class B (Style B) 4- 3, i `'� . ► Notification Initiation Circuits .. a • * E Appliance Circuits -` 1 ` 5235 Remote 0 n °:" t Annunciators'f4A in ~ SBUS Devices *f '+-----i. 5280, 5217, & 5824 To AC SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350318 Rev B, 11/05 ,, subject to change without notice. For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone:(800)328-0103, Fax:(763)493-6475. SYSTEM ` �..� SENSOR`91 41 Photoelectric Smoke Detectors if System Sensor's i3"'series smoke detectors represent • significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The P line redefines installation ease with its Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire the bases included • with the heads.The large wire entry port and in-line terminals •Large wire entry port provide ample room for neatly routing the wiring inside the base. ▪In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, •Mounts to octagonal and single-gang backboxes,4-square as well as direct mounting with drywall anchors.To complete the backboxes,or direct to ceiling installation,i3 heads plug in to the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base •Removable detector cover and chamber Intelligence.i3 detectors offer a number of intelligent features •Built-in remote maintenance signaling to simplify testing and maintenance.Drift compensation and smoothing algorithms are standard with the i3 line to minimize •Drift compensation and smoothing algorithms nuisance alarms.Two-wire i3 detectors needing cleaning can •Simplified sensitivity measurement generate a remote maintenance signal,when connected to the •Wide angle,dual color LED indication 2W-MOD2 loop test/maintenance module,or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the •Loop testing via EZ Walk feature module and the panel.The SENS-RDR,a wireless device,displays the •Built-in test switch sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection.The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol,the EZ Walk loop test feature is available on two-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® ® 4,-MT 5 MEA MSFM LISTED APPROVED Ill approved approved 3011446 7272-1209:210 290-01-E 2093 Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i'Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel,and shall provide a loop testing capability to verify the circuit without testing each detector individually. Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12V,23mA @ 24V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz.(178 grams) Operating Temperature Range 2W-B and 4W-B:32°F-120°F(0°C-49°C);2WT-B and 4WT-B:32°F-100°F(0°C-37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft.nominal Input Terminals 14-22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current No 2-wire 130 mA max.limited by control panel Yes 2-wire 130 mA max.limited by control panel No 4-wire 20 mA @ 12V,23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V,23mA @ 24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 in.(16.76cm)diameter SYSTEM 02006 System Senses. 3825 .•wuctsptAcawnsso ,.a,u wtn,,t,1nams.vs„ystLgnse,so.l,111 �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product Wort-nation,toducltrg the latest version oftha data sheet A050318-006.7/06•N16/6 L Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13009 SW 68TH PKWY A, TIGARD, OR, 97223 Commercial - Fire Protection System 998 Alarm Final PASS - No C of O FPS2014-00116 Chip Barnett Violation Summary: Inspector Contractor