Loading...
SGN2014-00062 CITY OF TIGARD SIGN PERMIT t . Permit#: SGN2014-00062 COMMUNITY DEVELOPMENT Date Issued: 06/23/2014 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 2S112AD00900 Jurisdiction: Tigard Name of Business: The Home Depot Business Address: 14800 SW SEQUOIA PKWY Applicant/Agent: Work Description: Wall sign(30 sq ft)-replace existing. Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: Yes Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 3'x 10' Total Sign Area: 30 Wall Area: 15200 Wall Face(Direction): South Sign Height: ft. Projection From Wall: 5 in. Illumination: Internal Materials: alum/plastic Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $178.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: Q - �f n wl pQr e Permittee Signature: CITY OF TIGARD SIGN PERMIT = r 0 Permit#: SGN2014-00062 COMMUNITY DEVELOPMENT Date Issued: 06/23/2014 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: Jurisdiction: Name of Business: The Home Depot Business Address: 14800 SW SEQUOIA PKWY Applicant/Agent: Work Description: Wall sign (30 sq ft)-replace existing. Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: Yes Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 3'x 10' Total Sign Area: 30 Wall Area: 15200 Wall Face(Direction): South Sign Height: ft. Projection From Wall: 5 in. Illumination: Internal Materials: alum/plastic Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $178.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: Permittee Signatur-. �� SeNAL EIe-„ ND'A- I pot ..acG I V,°�G✓ N __■ • City of Tigard Sign Permit Application TIGARD GENERAL INFORMATION Name of Development/Project `� -`` FOR STAFF USE ONLY V Site 0"C_ Q PbT Address/ Street Address Permit No.: S G M a 014 - Od o (o Location 19g0 < L) S vaia F ^ Suite/Bldg.# - City/State Zip � Approved By: 77744, or Date: la -(8 - I`'1 Name Receipt#: Property /71 L/ De.VG IO�bwe11 4 Map/Th#: a S I i A_I'}D 00900 Owner Maiiin Address 058� u Site Z I - P 1oning- PD x / Allowable Total Area: 15 eio City/State Zip { C� Phone R1-iu„ . CIA 5° `g Tenant or Name Electrical Permit Required? [Yes ❑ No Business /ey, ji Building Permit Required? ❑ Yes Igi No Name Rev.7/1/12 c\ampin\masters\land use applications\sign permit app.doc Sign Ccwt Se,t i4IA S Contractor Mailing Addres JJ Suite g166 &IC 7L1*4e City/Sta a Zip Phone REQUIRED SUBMITTAL ELEMENTS g r4,11 OZ g7S'at4 503-777-z(. J (Note: applications will not be accepted Oregon Coast.Cont Board License# Exp.Date without the required submittal elements) 63 /Z2 Proposed Permanent ❑ Completed Application Form P Peanent ❑ Freestanding ❑ Freeway ❑ 2 copies of site/plot plan,drawn to scale Sign all that Temporary I=1 Roof ❑ Electronic (3 copies,if a building permit is required) (Check apply) Wall ❑ Other size requirement: 81/2"x 11",or 11"x 17" (� 111 2 copies of elevations,drawn to scale !"`New sign? ❑ Alter to existing sign? (3 copies,if a building permit is required) Sign Dimensions:3t,c lO t! size requirement: 81/2"x 11",to 24"x 36" Total Sign Area(sq.ft.): • ,9 a/ ❑ $171.00 Fee (Permanent sign,any size) 0 Sign Data Total Wall Area(sq.ft.) .�1/ 3 � ❑ $54.00 Fee (Temporary sign,any type) .1.112e0 (Complete all Direction Wall Faces(circle one): items in this NOTES: section) N ciE W NE NW SE SW Height to top of sign(feet): 2q i ♦ Wall signs do not need to be drawn to scale, but Projection From Wall(inches): if" include dimensions of wall face and sign Materials: L placement. Rli++vn��+, ��iyTG ♦ Wall signs do not require site/plot plans. Will sign hav illumination? Yes ❑ No ♦ Freestanding signs over 6 ft. required a building Type: Internal External permit. Are there any existing freestan g or wall signs at this location, including wall signs that overlap a tenant space? ❑ Yes ❑ No If"yes",a list or diagram of all sign dimensions and square (OVER FOR SIGNATURES) footage must also be submitted. City of Tigard 1 13125 SW Hall Blvd.,Tigard,OR 97223 I 503-718-2421 I www.tigard-or.gov l 1 Page I of 2 APPLICANTS: To consider an application complete,you will need to submit ALL of the REQUIRED SUBMITTAL ELEMENTS as described on the front of this application in the"Required Submittal Elements"box. NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work. * When the owner and the applicant are different people, the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: ♦ If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted herewith, are true, and the applicants so acknowledge that any permit issued, based on this application, and may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application, including the policies and criteria, and understands the requirements for approving and denying the application. I hereby acknowledge that I have read this application,that the information given is correct,that I am the owner or authorized agent of the owner,and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each owner of the subject property are required. Applicant Signature Date &-P at fed' Signature of Owner/Agent Date QV/V�iFJMt -S _777- Ng65 C� Contact Person Name Phone No. City of Tigard I 13125 SW Hall Blvd.,Tigard,OR 97223 I 503-718-2421 I www.tigard-or.gov I Page 2 of 2 #4002 14800 SW Sequoia Pkwy Tigard OR Site Plan _ 0a1' tip - • Co.1.1:.,..,...: • ..., --L..*!,...,1",71"241X.11.".."11.1"'"-.1:iliiii... 1::::-4:'7-771.7' . _ ItIt4■04_4.. .,. . . _ . .. . ,..,t, 'vklillP111.11 - X- i f.. ' 9' x 9' r e M/T PLYON ' r' IL . ��, 4'THD 7 A _� - 4' THD =" - �r �I t r' 5' THD i lULL ,+. �='y t 2' X 14' "` , x 7, d .- THD ¶3' xlo' ;Rc - •; - i - Monument r -.r ' d. - i°' d .. .. r- - 4 • . - - -- 14.— - .. , 15 , D Installing new 3 'xlO' TRC Site Ca inet :• ,_,;,-,,,....„,,,„_....„,:: „:„.,:•;:„.„,,,,,_,,.....:i5. .'7 ..'','itAkti:"qr, trt,...;;; rs"'I. z- r I ware-.-ems• r M . . 9 ,. t t f)r yi t� . Y i r V`..C1`` te y y "#a ftsv. y� ts-r "` yy om?' 4 v fii. 4an 6A-4..,-,;.,-..• "4, ' x f ty.M{ y1r F ,1 .! •! i Y3..4.K. --i � � , i'- x l;4 ; 3:*,4 ° r 1i • a 4,,i L ai ;.. s 3 ',fit',,8 ,tiff" a h, '..' 1 a y"„:z w, fit-•i 3.`.t,,,-.,, W7�u ;.. • ..`t -:- U.eti: `_Y.. ..` F. „� ,.ric� fx•..,_. �i"W.f�._ �.-bg.^� ..1 .,. _. = « Y c i - r ApprOVe .. orditwrally APPkr describ�d n' -[ 1- � " ". — [?SoEer e RoM:eTyttteNhr OetwoAttach. S� r 'FroS llo4wµ••ao` aoo Job Address. 14 ■ lyS "• • FLA N ni-v \ ;i?nit! ir ph J ' +� ...... ............ ..�...r• �.■..�. �.��� �i .� -.L• ..r� 111/11111.11 - ti �h1 �, w t,. ; R i ✓ • 7 <.'7 t 1 ',Ilk LL ■ klk.I:4.N, • L 10.• • W•.'4/ .7.'", "1 � • *'---r..~1 �. '� to. - , . vt '' •.1� �.•!- ' .r,r•■' 2.wasp : ._ •r .r w i ti�.•• e ..rte... Er I../Mr, Mi .4.-14 r t rr , ,,,ttt.. N _I w _,, ' /'1 - i J Srr M. �... ____,,v up:•}t. • �j • ji, •�n Th!w+nr� a ......i s h. 14 1 1 E r . _... ,... ,* �,' .J. 1 YiVW NM.."".tea, .r•. �'" . ; lid .... '• �' . rWDO OR.COM AP'-` ../ s;- `/ 111111011r.."' Secondary Signage Cabinet Wall Sign 10'-a• - SPECIFICATIONS: co c I- O O n �n L—�1 1: SignComp(S/F Body#2025)extruded aluminum body with extruded 2 0 11 ,n�\ ILJ�VI interior electrical raceways. ;/ L 2: SignComp(Tension Frame#2085&1 1/2"Cover#2084)extruded 1Cg co 10 — I � aluminum hinged retainer system. '7 — jj 3: SignComp(Frame Brace#5350&Support Tube#2175)extruded aluminum face support bracket. 30.0 Sq. Ft. Scale:3/8'= 1'-0' HOM1S6F7001 4: .040 Aluminum sheet back affixed with pop-rivets every 12'on center. Note:Typestyle shown is Futura LT Pro Book Bold. 5: GE LED Power Strip(GEWHSSP3-65K)internal illumination. 1— 6: Panaflex vinyl substrate face. 6-1/4' Indkoha l 1/2'Realm, 6-1/4' t I 7: 3/4'Electrical conduit sleeve thru wall.Access hole to be sealed with 2 f`;I,W weatherproof silicon caulk. e ; 3 8: Weatherproof electrical junction box with 20amp snap switch disconnect. S--%. ; i Junction box is provided within five(5)feet of sign area by others. d 4 j 9: Approved flexible conduit housing electrical primary to power source IMltetle/e 5 Iii by others. LED Power StripSaysd 10: All electrical primary wiring to be UL listed and approved No.12. COMPONENTS CABINET SIZE TETRA PRODUCT POWER SUPPLIES suPP�r waF eNO cna 11: 20amp Visible exterior disconnect housed under weatherproof cover. 3-0'r 10-0' Tata Poo,Sldp-GEWHSSP3-41K GEP512-60U-NA 7 : o s/e°deep cuh1n.1 27 Module, Two(2)r-q••d 9409-23 ft GETMEC1 -3 ea 10 12: LED power supplies(GEPS12-60U-NA)housed in aluminum wire way. RI tl 8 13: 1/4"Weep holes. I■ 14: Fasten sign to wall with(8)eight 1/2'x 21/4"sleeve anchors evenly 1/2" 1/2" 11 I 9 spaced. I ' Background Applied Vinyl 3M 3632-44 Orange 12 -- � 14 COLORS x2 Outline Exposed Substrate t/ra''yltta•.r j Sign face=3M 945 Series Panaflex White 13 n Vinyl Overlay Background=3M 3632-44 Orange Black Applied Vinyl Letter in., 3M 7725-12 Black ■ Vinyl Letter Graphic=3M 7725-12 Black 1/2„ LED's=GE LED Power Strips GEWHSSP3-41K-White • Aluminum Cabinet&Retainers=Akzo Nobel B-15 Gloss Black Face and Outline Detail Not to Scale CLIENT: HOME DEPOT Customer Approval: Date: - SITE I VARIOUS ff PATTISON .p w,N �' ,. ,� ® ^,�.. „wmMa,.�. ^H $p uL ,,,.. ,a,Y ” -�« m- •' �r f El"' B 12ov Dan SALES REP.: E.MACKLE DATE 2-7-14 SIGN GROUP INC. �'�m.^ .ao,e.a^ DESIGNER: B.SMITH SCALE. AS NOTED 470 N.Ceder Bluff Rd. • Suite 101 . Knoxville,TN.37923 WWW. attisonsI 1T.COR7 Tel(8651693-1105•Fax(888■694.1106.Toll Free 1866)218-197fi P 9 REVISION: PAGE.' 1 OF 1 III CIg TY OF TIGARD RECEIPT 1 , 13125 SW Hall Blvd.,Tigard OR 97223 503.639.4171 TIGARD Receipt Number: 196592 - 06/23/2014 CASE NO. FEE DESCRIPTION REVENUE ACCOUNT NUMBER PAID SGN2014-00062 Sign Permit-LRP 100-0000-43117 $23.00 SGN2014-00062 Sign Permit 100-0000-43115 $155.00 Total: $178.00 PAYMENT METHOD CHECK# CC AUTH.CODE ACCT ID CASHIER ID RECEIPT DATE RECEIPT AMT Check 1499 CCAINES 06/23/2014 $178.00 Payor: Ramsay Signs, Inc. -Permit Account Total Payments: $178.00 Balance Due: $0.00 Page 1 of 1