ROW2014-00065 CITY OF TIGARD RIGHT OF WAY PERMIT W COMMUNITY DEVELOPMENT Permit#: ROW2014-00065 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/18/2014 T[GAKD Parcel: SEG848 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: TW Telecom, Inc. Project Description: Adjacent to SW 72nd Avenue and SW Elmhurst Street from SW Clinton to SW Hermosa Way. Relocated existing aerial facilities underground for the Tigard SW 72nd/Dartmouth project. TW is proposing to pull fiber through 4"conduit that is being placed by others.SEG 848,933,775, 934, 3145,989 Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX: Applicant: DAVID MINER 520 SW 6TH AVENUE, SUITE 400 PORTLAND, OR 97204 PHONE: 503-710-6296 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant f� Signature: t y�IV 1 preslAG'^ ' It-&11LIA Issued By: 411/* Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for ROW2014-00065 Type: Condition Name: Status: Severi : ROW 01-CUSTOM CONDITION Applied Notice <Custom Condition goes here> ROW 02-PERMIT&PLAN REQ ON SITE Applied Notice A copy of the permit and all attachments,and a copy of the approved construction plan and all amendments shall be available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's Standards and Specifications and to these General Conditions. Changes to any of the aforesaid must be approved by the City, in advance of work performance. ROW 03-TRAF CTRL-SPECIF(CITY) Applied Notice The City's standard specification for traffic control is"Manual on Uniform Traffic Control Devices for Streets and Highways", U.S. Dept.of Transportation, F.H.A., 1988 Ed. ROW 04-TRAF CTRL-CONTR RESPON FOR Applied Notice Traffic control shall be provided for by the contractor in accordance with the City's standard specification and, also, in accordance with a City(job specific)approved traffic control plan.A copy of the approved traffic control plan shall be available at the work area. ROW 05-TRAF CTRL-ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic,at any time,without having first obtained written approval from the City Engineer.The permit holder is responsible for provision of timely notification of traffic flow disruptions to area wide Emergency Services(Tigard Police Dept.,Tualatin Fire&Rescue)and to Tri-Met and Tigard School District. ROW 06-TRAF CTRL-ADVANCE WARNING Applied Notice Advance warning of imminent traffic disruption shall be provided to the general motoring public by placement of an advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. ROW 07-TRAF CTRL-PRIV PROP ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service and if not, shall be cause for work stoppage until effective access is established. ROW 08-TRAF CTRL-DEVICES IN PLACE Applied Notice Traffic control devices,flagpersons,etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. ROW 09-TRAF/NOISE CTRL-WORK HRS Applied Notice No work will be permitted during the hours of darkness, nor between 9:00 p.m.to 7:00 a.m. Monday through Friday, nor between 9:00 p.m.to 8:00 a.m. Saturday, nor between 9:00 p.m.to 9:00 a.m.Sunday. ROW 10-TRAF CTRL-MIN LANE WIDTH Applied Notice Minimum travel lane width shall be eleven(11)feet; pedestrian travel shall also be provided for. ROW 11-TRAF CTRL-CITY CAN MODIFY Applied Notice The City reserves the right to add to or modify traffic control requirements as may be necessary to effectively control traffic and to assure public safety. ROW 12-INSP 24 HR NOTICE REQUIRED Applied Notice The permit holder or his contractor shall notify the City's inspectorKenny Fisher at 503-816-6146 or email at kenny @tigard-or.gov,twenty-four(24)hours prior to commencing work,twenty-four(24)hours prior to any staged inspection, and after completing work covered by the permit. ROW 13-HAZARDS-CERT OF INS Applied Notice Maintenance of the work area and approach roads is the responsibility of the permit holder.The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards.A copy of the permit holders Certificate of Insurance shall be available at the work area. ROW 14-DEBRIS-MATERIALS Applied Notice The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit.The City may at any time order immediate cleanup and stoppage of work to accomplish cleanup. ROW 15-EROSION CTRL REQ Applied Notice Effective erosion control is required. Erosion control devices must be installed and maintained meeting D.E.Q. requirements.The City may at any time order corrective action and stoppage of work to accomplish effective erosion control. ROW 16-REPAIRS-LIKE MATERIALS REQ Applied Notice Property disturbed by construction activity shall be seeded with a standard grass mix; shrubs,flowers, barkdust,existing signs, pavement markings, mailboxes,etc.,shall be reestablished, reinstalled or replaced,with like kind and material. ROW 17-DRAINAGE CONTROL REQ Applied Notice Effective drainage control is required. Drainage shall be controlled within the work site and shall be so routed that adjacent private property, public property and the receiving system is not adversely impacted.The City may,at any time,order corrective action and stoppage of work to accomplish effective drainage control. ROW 18-UTILITIES PRELOCATION REQ Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0010 through OAR 952-001-0080. Copies of the rules may be obtained from the Center by calling(503)232-1987. If you have questions about the rules,contact the Center.NOTE: Damage to utilities shall be corrected at the permit holders expense. ROW 19-UTILITY LOCATIONAL CONFLICT Applied Notice Contractor must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the permit holders expense. Changes must be approved by the City in advance of work performance. Contractor shall coordinate the work with affected utility agencies. ROW 20-TRENCH-PATCH/SAFETY/LBILITY Applied Notice A temporary hard-surface patch(Cold mix A.C.or Hot mix A.C. base paving) shall be placed on trenches within roadways at the end of each day's work. No trench,on site or off site,shall be left at any time in an unsafe condition.The permit holder is responsible for and is liable for hazards or damage resulting from the work. ROW 21-REPAIRS REQ-INSPTR OPINION Applied Notice Work provided for under the permit shall include repair of existing facilities(roads,ditches, etc.)as may be necessary, in the City Inspectors opinion,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the permit holders expense. ROW 22-AS-BUILT/ENGR CERTIF REQ Applied Notice At the end of each year, or an a mutually agreeable yearly date,any entity making changes to its facilities in the public right-of-way shall submit complete"as-built"drawings showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineers certification of installation compliance(form attached). ROW 23-DAILY INSP REPORTS REQ Applied Notice The permit holders Engineer/Inspector shall submit daily inspection reports,on a weekly basis,to the City's Inspector. (see Developer-Engineer Agreement note#5). ROW 24-TESTS/REPTS TO VALIDT CLMS Applied Notice The City's Inspector may, at their discretion, require provision of tests and or reports from the permit holder, permit holder's engineer or contractor to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the permit holder's expense. ROW 25-RELEASE-WAIVER REQ Applied Notice The permit holder shall provide a copy of a properly executed Release&Waiver document to the City for each ownership disturbed by construction activity, as evidence of disturbance resolution and owner satisfaction. ROW 26-MONUMENT PROTECTION REQ Applied Notice Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holders expense. ROW 27-PROB SOLVING-RESPON PARTY Applied Notice The permit holder shall provide to the City Inspector, in writing,the names and 24-hour emergency telephone number of two (2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of an emergency. The permit holder shall notify the City Inspector, in writing,of any/all assignment changes. ROW 28-CONSTR SAFETY-RESPON PARTY Applied Notice The permit holder shall cause his contractor to provide to the City Inspector, in writing,the name and 24 hr emergency telephone number of a designated"Competent Person"responsible for construction safety as per OR-OSHA, Chap.437, Div. 3 Construction, Subdivision P-Excavations.The contractor shall notify the City Inspector of any/all assignment changes. ROW 29-ESMT/RT OF ENTRY-RESPON Applied Notice It is the sole responsibility of the permit holder to provide for proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry,or properly executed easements,shall be provided to the City.The City shall in no way be construed to be liable for the permit holder's failure to obtain or provide for proof of right-of-entry or easements. RECEIVED JUN 1 2 2014 II City of Tigard yin,OF ■ Application For Work In The Ri`� i '-rfbi� �� pp g ity TIGARD ROW Permit , FOR STAFF USE ONLY General Information: Right-of-Way�,�, Property Address/Location(s):SW 72nd Ave and SW Elmhurst St Case No.: IOW 2014— OS- TW Project Number:TW-3283-2314 S B4g, et 33 i i15,°3`F i 7(45 Receipt No.: lj A- /W Date: (P l 11P I I *Applicant's Name:TW Ielemd Inc Application Accepted By: Pc 14- Address:520 sw err Ave,Suite 400 Revised 7/1/10 ��,,,//,�( City/State:Porneod,OR Zip:97204 b r/6 ' /I —o— !6 Primary Contact°avid lad& REQUIRED SUBMITTAL Phone:(3)71°4298 Fax:(503)416-1555 INFORMATION Contractor's Name:North SkY Communications.inc. CCB#CCM 141171 Expiration:03101/2016 Submit a scaled sketch of the proposed Address:1°86°SW a"Rd work to be done City/State:Sharw°od.OR Zip:97140 Phone:(503)847 1 Fax: (503)647-9971 Professional Engineered Plans are required for: Plans By:Kee Technical Solutions • Street Widening Address: 6566 SE 141a Rd sm F • Subdivision Infrastructure City/State:ww e.OR Zip:97222 • Main utility line extension Phone:(503165041041 Fax:(503)650-7390 I:curpin\masters\land use applications\row app.docx Description of work: TW Telecom is proposing to relocate existing aerial faotties underground for the city of Tigard 72nd and Dartmouth Project.TW is proposing to put fiber through 4'conduit that is being placed by others. Estimated value of work(within the public right-of-way): $-$1500.00 Is work related to a LAND-USE DECISION? YES ❑ NO ❑ If so) please specify(MLP,SDR,SUB,etc.)case#: Is the work related to a BUILDING PERMIT? YES ❑ NO ❑ If so) please specify(BUILDING PERMIT)case#: *NOTE:Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for the work. City of Tigard I 13125 SW Hall Blvd.,Tigard,OR 97223 I 503-718-�4 www.tigard-or.gov ( Page 1 of 1 I 2011 Edition Page 81 Shoulder Work w/ Minor Road Encroachment Diag. 300 ROAD WORK ♦ 5f. AHEAD • Initial Warning A • Sign • • • (Optional) • • • � -�= n al Protection(both Option w/TMA(both Optional) See Chapter 4 Buffer • 10' • minimum • • • • A ROAD NARROWS l (OPtionari B 5pf , - AHEJID Initial Warning December 2011 Chapter 5 Page 80 2011 Edition 5.3 Two-Lane, Two-Way Roads Shoulder Work w/ Minor Road Encroachment Diag. 300 Use this detail for non-freeway work which extends into a travel lane and maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane can not be maintained, or when traffic can not safely pass by in both lanes simultaneously, use the appropriate lane closure diagrams—for example, Diagrams 310 through 350. A lane closure may be appropriate for conditions such as high traffic volumes, high speeds, and inadequate approach sight distance to the work space, or heavy equipment adjacent to the travel lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Cones shall be placed along the entire length of the work space. If a protection vehicle is used and work is in place one hour or less, the taper and tangent devices may be omitted. 4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there is limited sight distance, consider placing cones or tubular markers on centerline. 5. An arrow board in caution mode or truck-mounted PCMS with "SHOULDER WORK" or other appropriate message may be used for higher visibility. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs Buffer Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 40 350 350 350 - 150 45 180 50 500 500 500 210 — 55 250 Chapter 5 December 2011 f CONSTRUCTION NOTES 1 3 7140 - —- - 1. ALL WORK AR O BE RESTORED TO LIKE OR BETTER CONDITION. o I 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING LOCATES OR UTILITY I STRUCTURES. T --- ----- I 3. IT IS THE CONSTRUCTION CONTRACTORS RESPONSIBILITY TO CALL FOR LOCATES N BEFORE DIGGING. x z LEGEND 11750 11780 v.)11720 11810 AERIAL CONSTRUCTION 11860 ! 11930 11930 AERIAL OVERLASH 0 1 DIRECTIONAL DRILL • - EXISTING CONDUIT - - RIGHT OF WAY R/w PULL FIBER THROUGH EXISTING 4" PROPERTY LINE Dc CONDUIT PROVIDED IV OTHERS. EASEMENT EDGE OF PAVEMENT EOP EXISTING GAS 96CT 20+48 °+ loo °o PGE o 24CT 6+09 o M/a_ _ _ 495 M/O+'- i' M/�_ —M/� i495L EX STING ELECTRONE w M/� 6714 25I� -1 ° EXISTING ELECTRIC E M/b ' ^ i'm/ei 24CT 50 843 - - �Nll b _/ I I _ _ �- 233 I ° o I EXISTING SANITARY SEWER SE o ° CC; °° I EXISTING STORM DRAIN SD TWTC °o oM N N N ,; EXISTING STORM INLET N N EXISTING FENCE X- SW 72ND AVE EXISTING UTILITY POLE PROPOSED UTILITY POLE 0 35'-5-2014 R/W- R/W R/w EXISTING FIRE HYDRANT ---- - R/W R/W TREE ------------ - R W R'w- j R/W R/W R/W- EXISTING STREET LIGHT A j RECEIVING AND/OR BORE PIT L__1 VTI I 7501 7275 SPECIFIED VAULT i I I 3 AS—BUILT 2 REVISION / 1 1 06/11/14 T.H. J.M. ORIGINAL • NO. DATE ENC DESIGN DRAFTING COMMENT �tw telecom. ATTBITIOIt Orogen We maim yea tefellow TW TELECOM ENGINEER Dave Miner-503.710.6296 tulle saapeedb7 the Dew UeRyMereYen --c‘di ENGINEERING FIRM:K&B Technical Solutions Color.Theo efts w sat bra In OAR 162- OOI.0O1G6n6Ir se /6?OOt.c 0.Yee may eaten PROJECT NUMBER PA seeks at ria nMs b7 ailp Oa oerrsr.Pam LOCATION: SW 72ND-SW PACIFIC HWY TO SW GONZAGA Ste Ykperu member krSe anew UM 0 10' 20' 30' 40' 50' AND SW ELMHURST-SW 72ND TO SW 69TH Nere/en Cyder Is MR 2712-1667 a 611). lilT1. DRAWING NAME Porn*Drswbq.dwp SCALE: 1"=50' _CONFIDENTIALPROPRIETARY SHEET: 1 OF 4 CONSTRUCTION NOTES 1. ALL WORK AREAS TO BE RESTORED TO x LIKE OR BETTER CONDITION. * 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING LOCATES OR UTILITY N STRUCTURES. I 3. IT IS THE CONSTRUCTION CONTRACTORS o RESPONSIBILITY TO CALL FOR LOCATES 12625 BEFORE DIGGING. o "' c 12120 LEGEND ct . AERIAL CONSTRUCTION -` ,..... J 11930 11990 AERIAL OVERLASH DIRECTIONAL DRILL — - - EXISTING CONDUIT - \i� RIGHT OF WAY R/w PULL FIBER TF�ROUGH EXISTING 4" PROPERTY LINE CONDUIT PRO IDED BY OTHERS. EASEMENT + 96CT 28+57 o EDGE OF PAVEMENT EOP 96CT 25+43 0 00 0o 24CT 14+18 o °4- EXISTING GAS 24CT 11+04 0 _ _ _ + _ _ _ _ ± I �— m/8_ - w-- EXISTING WATER j495�M/_ VT-2 - M/d .- - - 314' - 233 _ _ _ /a 352' x- -I _ _ EXISTING TELEPHONE M M - - + TWTC I �, I EXISTING ELECTRIC 233 I I I I ° o EXISTING SANITARY SEWER SEW - — TWTC °o ° °+ EXISTING STORM DRAIN o° °- o0 0 + rn o N °�° �+ "' EXISTING STORM INLET SD `� `" EXISTING FENCE x PULL FIBER THROUGH EXISTING 4" CONDUIT PROVIDED BY OTHERS. SW 72ND AVE EXISTING UTILITY POLE PROPOSED UTILITY POLE O 35'-5-2014 EXISTING FIRE HYDRANT V R/W 1 R/W R/W R/W R/W - -- R/W- TREE 0 R/W R/Vy EXISTING STREET LIGHT A 4'i� 1 RECEIVING AND/OR BORE PIT L__J \ (--- 1 VI # SPECIFIED VAULT cr 0 11985 7255 m \ 3 AS-BUILT 2 REVISION / 1 1 06/11/14 T.H. J.M. ORIGINAL iiii NO. DATE ENG DESIGN DRAFTING COMMENT �tw telecom. ATTENTlOIt Olepn iew needles you be follow TW TELECOM ENGINEER:Days Mlner-503.710.8288 nMs saepMd by M Onpen U91y Ngdkae.n ' K&ENGINEERING FIRM: B Technical Solulone Carew.Team New we• bA,in OAR 952- 001-0010 052-001-0000 yob may°Wein PROJECT NUMBER PA copies of dal tress by cser%9n ewesr.mobs LOCATION: SW 72ND-SW PACIFIC HWY TO SW GONZAGA Si.~one number br M Oregon UMW 0 ID' 20' 30' 40' 50' AND SW ELMHURST-SW 72ND TO SW 88TH NOMC.Uen Cwrw Is(503)292-19917 a 811). 1 .1 . 1 DRAWING NAME Pent orwtip.e■y SCALE: 1"=-50' CONFIDENTIAL/PROPRIETARY SHEET: 2 OF 4 '_ j CONSTRUCTION NOTES 7130 I 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR BETTER CONDITION. 3 2. ALL OTHER UTILITIES ARE BASED OFF O_ EXISTING LOCATES OR UTILITY — --------- -- -- STRUCTURES. 3. IT IS THE CONSTRUCTION CONTRACTORS D RESPONSIBILITY TO CALL FOR LOCATES ce BEFORE DIGGING. 12360 w \ LEGEND AERIAL CONSTRUCTION -- AERIAL OVERLASH 12260 j DIRECTIONAL DRILL 24CT 18+28 EXISTING CONDUIT -R/: T E 9299-NEW PULL FIBER THROUGH EXISTING 4" RIGHT OF WAY PULL FIBER THROUGH EXISTING 4" ,� , CONDUIT PROVIDED BY OTHERS. j PROPERTY LINE CONDUIT PROVIDED BY OTHERS. � xo EASEMENT ° 96CT 32+09 EDGE OF PAVEMENT EOP °+ 24CT 17+7 zi EXISTING GAS u�� �M x(352) - -4 �, PULL FIBER THROUGH EXISTING 4" EXISTING WATER -- W •• _ - • \ CONDUIT PROVIDED BY OTHERS. EXISTING TELEPHONE —T— w I233 \ _ M/a 352' ll TWiC _ _ _ 1_ _ _ EXISTING ELECTRIC E o I '� - M/al ' M/2i 96CT 30.5+6512r 35+82 EXISTING SANITARY SEWER SEW + cO �+, °° ° 1060 EXISTING STORM DRAIN SD '' + °+ 0 122f EXISTING STORM INLET O M 233 SW 72ND AVE TWTC EXISTING FENCE X alliktiV% EXISTING UTILITY POLE R/W R/W ` ` PROPOSED UTILITY POLE O 35'-5-2014 EXISTING FIRE HYDRANT V R/W R/W / R/W R/W R/W R/W tii, TREE I EXISTING STREET LIGHT RECEIVING AND/OR BORE PIT F Q R --� /W 12335 03 uT- \ SPECIFIED VAULT i cr i 12215 12235 3 a 3 AS—BUILT 2 REVISION iM 1 1 06/11/14 T.H. J.M. ORIGINAL NO. DATE ENG DESIGN DRAFTING COMMENT �tw telecom. ATTENTION:Owen my nprsS you to lobo TIN TELECOM ENGINEER Dave Miner-503.710.6296 Mee sseplWbyV Oman UM Naillesllen ---- ENGINEERING FIRM:K&5 Technical Solutions Order.These ogee see eM ORO In OAR MO- 0 101.0010 wpr9 ou624101-0pp.You may Obis PROJECT NUMBER PA copies alive Ma by wing Si.esnSf.(Nolo LOCATION: SW 72ND-SW PACIFIC HWY TO SW GONZAGA Met iepllaw number Syr Ms Own UllRy 0 10' 20' 30' 40' 50' AND SW ELMHURST-SW 72ND TO SW 69TH NoIlses6on Csnssr Is(00312:0-1111117 co 611). DRAWING NAME:Penny Orawkg4wp SCALE: 1"=50' CONFIDENTIAL/PROPRIETARY SHEET: 3 OF 4 / / I CONSTRUCTION NOTES w 1. ALL WORK AREAS TO BE RESTORED TO \ ce LIKE OR BETTER CONDITION. I g 12170 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING LOCATES OR UTILITY STRUCTURES. I j 3. IT IS THE CONSTRUCTION CONTRACTORS ■ 1 RESPONSIBILITY TO CALL FOR LOCATES ' 1L BEFORE DIGGING. 7085 0 g > `� 12123 Q cr LEGEND I I '" rn AERIAL CONSTRUCTION O car, ■ a AERIAL OVERLASH P- -.-. "' 12190 DIRECTIONAL DRILL 1 w EXISTING CONDUIT - - I o° RIGHT OF WAY R/w g $ ., PROPERTY LINE / .r M/2i 24CTm22+58 $ ��\ N '�(NTS) N EASEMENT OR PGE + EOP M/�! EDGE OF PAVEMENT EOP NT/500653 N O� EOP EOP EXISTING GAS ■ - EP26+00 EXISTING WATER -w- limn .■� �� - - I SW ELMHURST ST o I PULL FIBER THROUGH EXISTING TELEPHONE Lri SW ELMHURST ST dO3 d03 EXISTING 4" CONDUIT. SW ELMHURST ST EXISTING ELECTRIC - —E- - 803 PULL FIBER THROUGH - - d03 d03 - EXISTING 4" CONDUIT. * - --- - ----__—_ d0 u, EXISTING SANITARY SEWER --SEW —R/W I R/W R/W R/W [LA R/ 340' EXISTING STORM DRAIN —so I 253TA -011386 s_ -_R/N, EXISTING STORM INLET C-J I 1Cq Q EXISTING FENCE X 24CT 26+58 ao EXISTING UTILITY POLE L.1 PROPOSED UTILITY POLE O 35-5-2014 1 12259 EXISTING FIRE HYDRANT 3 1 x TREE y, ■ EXISTING STREET LIGHT I Cr 7070 \ x = RECEIVING AND/OR BORE PIT L__J IL!, 7040 i- p o W 3 co Cr) �' SPECIFIED VAULT 3 \ cr 12300 i i I 3 AS-BUILT 2 REVISION f 1 1 06/11/14 T.H. J.M. ORIGINAL III NO.- DATE ENG DESIGN DRAFTING COMMENT .tw telecom. ATTENTION Oregon tort requires you ssram TW TELECOM ENGINEER: Dave Miner-503.710.6296 rules aesplsly The Thew MyNewoss.n ENGINEERING FIRM:KM Technical Solutions Caner.Those NdSS me forth M OAR N2- _PROJECT NUMBER: PA- 0014010 Ora.tf?OO1f40110.Yea as7.ESin soONS O The nos Naar.b Nara.INe1r LOCATION: SW 72ND-SW PACIFIC HWY TO SW GONZAGA Ts5I ISphaa writer imMe Orem IAN 0 10' 20' 30' 40' 50' AND SW ELMHURST-SW 72ND TO SW 69TH Nolresam Mater Is 003)232-19•7 or Oil). DRAWING NAME:Porn*Owwa va.d.q SCALE: 1"=50' CONFIDENTIAUPROPRIETARY SHEET: 4 OF 4