Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 1111 • COMMUNITY DEVELOPMENT Permit#: FPS2014-00110 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/18/2014 TIGARD Parcel: 2S101 CB00400 Jurisdiction: Tigard Site address: 12700 SW HALL BLVD E Project: Tigard Central Industrial Subdivision: 2007-064 PARTITION PLAT Lot: B Project Description: Buildings E&F. Install(4)fire sprinkler heads in(2)new offices. Contractor: AFP SYSTEMS INC Owner: NORRIS&STEVENS 19435 SW 129TH AVE 621 SW MORRISON ST SUITE 800 TUALATIN, OR 97062 PORTLAND, OR 97205 PHONE: 503-692-9284 PHONE: 503-225-8445 FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-COM 06/18/2014 $64.54 12%State Surcharge-Building 06/18/2014 $7.74 Type of Use: COM Plan Review-Fire Life Safety-COM 06/18/2014 $25.82 Class of Work: ALT Type of Const: Occupancy Grp: Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $98 10 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $1,000.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility ca ion .-nter. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You ma •: -in a copy of the rules or dir t questions to O \C by • ins 503.232.1987 or/111..8000.332.2344. Iss ed By: '/ /1J tec" ��' Permittee Signature: _ r GC/` • `CJV Call 503.639.4175 by 7:00 a.m.for the next available ins section date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System RECEIVED / 11)It I II I Ic 11 1 () 11 1111 City of Tigard nae/13� %/L'��� PermitNo.: `�,`� �� • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review • Phone: 503.718.2439 Fax: 503.598.1N 1 8 2014 Date/By: Other Permit: Inspection Line: 503.639.4175 Date Ready/By: kris ® See Page 2 for T WARD Notified/Method: Supplemental Information Internet: www.tigard-or.gov CITYOFTIGARD Pp TYPE BIJIUJIlitIG DIVISION REQUIRED DATA:1-AND 2-FAMILY DWELLING El construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El I-and 2-family dwelling 51 Commercial/industrial Valuation: $ El Accessory building El Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: (Z100 $t,1 OA U. 61a 0 • 8(IN c9, E ii:" — New dwelling area: square feet City/State/ZIP: .'rt 5A At) OK 91 13 3 Garage/carport area: square feet Suite/bldg./apt.no.: ll Project name: ft lira gi a C6M11;At s„,(6 , _ Covered porch area square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 1.191.4 LL Cyr 1y5 ° 61g rigE 717I4Ird(EIS 4E0 0 s /AS Valuation: $ /ODD. Oa C-z. �G� (› f- c G 5. Existing building area square feet New building area: square feet 13 PROPERTY OWNER I ❑ TENANT Number of stones: Name: 0t9 ,C )s et j�E vEr,5 Type of construction: Address: /011 6 W ,.M b iZ R l5D NI St, 6 V 1 ti sob Occupancy groups: City/State/ZIP: PD0(AND I)R 9 7 Z-O7 Existing: Phone:(ro3) Z 2 S 3'4Y S Fax:( ) New: ($ APPLICANT ❑ CONTACT PERSON NOTICE Business name: A 69 j j.&EM§ All contractors and subcontractors are required to be Contact Horne: Gbh I it �� licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: ( 9 t_1 '3 5 S 1A) i Z-9'6 y e jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons �tj/ IA+(NI (9R 4110le Z apply: Phone:(rO3) q 2, ci Z-8 Pi Fax::( ) E-mail: CONTRACTOR BUILDING PERMIT FEES* Business name: 4'A fI G (Pfisrs►dertolasciisdltls) Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): FLS plan review(40%ofpermit fee): Phone:( ) Fax:( ) (Due upon application.) CCB lie.: (D 7 jj 3 y Total permit fees: .}� 1 Amount received: '7' 9F,, Authorized signature: A This permit application expires if a permit is not obtained Print name: efi;t C l '1 o W!J Date: GI 1 ', 1_1 ( .4 J within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board I1Building\Permits\FPS-PermitApp.doc Rev 01/05/2012 440-4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ❑ 1-10 heads: No plan review required. El Alteration ❑ 11+heads: Plan review required. ❑ Repair Number of sprinkler heads: _ Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal(see A,B&C above): $ Permit fee based on project valuation(see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge(12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ Plan review requires a completed application and three(3) sets of plans at submittal. Plan review fees are required at submittal. I:\Building\Permits\FPS-PeimitApp.doc Rev 01/05/2012 2 f/°570/'i- 6r-C? t/0 AFP SYSTEMS, INC. PROJECT:-[; 14 Co4kfal IosiAti 7t( 'y, AUTOMATIC FIRE PROTECTION 1ala3. )r' 19435 S.W. 129th Avenue (503)692-9284 - - >, DATE: t-IL- y�� � Tualatin,OR 97062 FAX(503)692-1186 ��� ''-RF�o14r° �___ 13'_0" CEIVEJ [N . . 7 N " AIM`'' A :// D 1 R -3ia5. E z-lw u2-,tr�\''ck ■l• - zit 0( . MEN ,-,T,' liiiiiii 1 t ■•11 Instill �e.a,15 7n elEs., et- iiiiiii neoll t It ,oly U■ f�� f$. a CcnwS p N1A l3 Ofo�tc1c- aUx. darn r' 6c fr"fi'ff\ F9'A3. iiiiiiii, `szi iiiiiiiiiiii ' g;-. ' iiii ' Miiiiiii : iiiiiiiiiiiiiiii ‘.. iiiiiiiiiiiiiiiiiiiiiiiE 1 ' ' ....U... ■..... ..■ it . U»UUUUU ■■■U....■■■■ ■ UU■UUUiiiiii ■UUUUUUUUUUU ■ii• mum..... 11111111 111111111 111111111111 1in1111ii1 1111 , IIIIII 0 NU.. =ME .. ■ a•••■ ■ mum ray_ 1 _ .U.m.ii ■.. ■ MEa• m• ami E i _, .1. 3''X1 Yz" 1&) SIGNED: FIRE SPRINKLERS SAVE LIVES Vico Worldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers t Description described herein must be installed and « maintained in compliance with this doc- ,r_- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable r { Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- ' Sprinklers described in this data sheet tion Association, in addition to the stan- ` t are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- - - cies such as banks, hotels, and shop- The owner is responsible for maintain- - ping malls. ing their fire protection system and "* - devices in proper operating condition. • ;; The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with li i I ble, is intended for use in areas with a any questions. 4114,4001,..,— finished ceiling.This recessed pendent sprinkler uses one of the following: S rinkler I': • A two-piece Style 15 Recessed p ';; Escutcheon with recessed adjust- Identification " - r meet up to 5/8 inch (15,9 mm) from the flush pendent position. Number (SIN) �, y �! • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT , i ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2-NPT .. the flush pendent position. 1: The adjustment provided by the Mc I;: E:, Te l; Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) i'' to the sprinklers must be cut. 155°F(68°C) 1' 175°F(79°C) 1' Intermediate level versions of Series Approvals I. p UL and C-UL Listed 200°F(93°C) I, TY-FRB Sprinklers are described in 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB, and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A '1 and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper •The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass ' Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze I' WARNING"that provides cautions K=5.6 GPM/psi1r2(80,6 LPM/bar1t2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and ,I' installation can permanently dam- '` age a sprinkler system or its compo- nents and cause the sprinkler to fail I l: to operate in a fire situation or cause it to operate prematurely. �' Page 1 of 4 FEBRUARY 2014 TFP172 1. I I; TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* \ i : 5 sl ! 7/16" i. 1.11 (11,1 mm) m1!` . 4 ( NOMINAL 2" t MAKE-IN (50,8 mm) f ��i 3/�r w p. (50,8 mm) (34,9 mm) I vi. 3, ` I WRENCH 1 1 f� FLATS f 1/2"NPT** DEFLECTOR* - 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 1 L. Operation Installation , The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, �' ,..,.. ' WRENCH RECESS I;expands when exposed to heat.When Upright(TY313)and Pendent(TY323) 1; (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- Iii fluid expands sufficiently to shatter the dance with this section. I glass bulb, allowing the sprinkler to I. activate and water to flow. General Instructions ,' FIGURE 2 Do not install any bulb-type sprinkler if i II W-TYPE6 the bulb is cracked or there is a loss 1! SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- :. kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter ,:i RECESS of the air bubble is approximately 1/16 i, The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and i! Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) et��,� Sprinklers are intended for fire protec- temperature ratings. j tion systems designed in accordance i;l with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min , Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 ;: �- is based on the requirements of NFPA ft. lbs. (9,5 to 19,0 Nm). Higher levels ;' ►..� 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment Data Sheets).Only Style 15 or Style of the sprinkler. IN TO ENSURE ) Y the St Y ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. i> SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following i. instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Ii . TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 2 , DIA. 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4'DIA. _ Sprinkler Wrench to the wrench flats. FACE OF - (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers 1 \ .. FLUSH _ The Series TY-FRB Recessed Pendent 3/8±5/16" 1 I - Sprinklers must be installed in accor- (9,5±7,9 mm) %/ alb '7' dance with the following instructions. ' — ! Step A.After installing the Style 15 or MOUNTING 1/8"1/8" i Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread -------_ — sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the 43/ " sprinkler fitting. TY FRB PLATE (19,1 mm) Step B. Tighten the sprinkler into the FIGURE 4 Step fitting gh using sprinkler the into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7 Recessed Sprinkler Wrench -Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench Illl to the sprinkler wrench flats. Torque 2-7/8"DIA. - sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF j' Step C.After ceiling installation and fin- SPRINKLER 2-1/4"DIA. y ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- kler and push the Closure over the (759± s 4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + - FLUSH contact with the ceiling. Am 1 7 Care and f I —�� — MOUNTING i 1/8" j Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, - ---- Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 ; Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion,but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. after installation. Sprinklers damaged klers are not used for hanging any P 9 objects and that the sprinklers are only by dropping, striking, wrench twist/ slippage,or the like,must be replaced. cleaned by means of gently dusting Also, replace any sprinkler that has a with a feather duster; otherwise, non- cracked bulb or that has lost liquid from operation in the event of a fire or inad- q { its bulb.(Ref. Installation Section. vertent operation may result. ) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of their fire protection system and devices sion must be replaced. in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion(e.g., NFPA 25), in addition to the ' i'. TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)" 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2`NPT) TY323 4 SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection, 9 CHROME PLATED 200 200°F 93° for example,77-370-4-175-1 200 ((93°C) Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). )' Sprinkler Assemblies with NPT i;. Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), • K=5.6, Quick Response,(specify)tern- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon • Specify:Style 15 Recessed Escutcheon • with (specify*)finish, P/N (specify*) f' Specify: Style 20 Recessed Escutch- eon with (specify*)finish, P/N(specify*) • Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 • Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 • GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation, Fire Protection Products