Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2014-00124 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/11/2014 Parcel: 2S103ACO2200 Jurisdiction: TIG Site address: 11400 SW FONNER ST Project: BEAN PARTITION Subdivision: Lot: Project Description: Demolition of a 900 sq.ft.home. Contractor: HEWITT CONSTRUCTION LLC Owner: JOSH BEAN PO BOX 2212 2744 SW SCHOLLS FERRY RD HILLSBORO, OR 97123 PORTLAND, OR 97221 PHONE: 971-246-0501 PHONE: 503-273-5974 FAX: 503-629-0196 Specifics: FEES Description Date Amount Type of Use: SF Class of Work: DEM Type of Const: Permit Fee-Additions,Alterations, 05/29/2014 $119.33 Demolition Occupancy Grp: Occupancy Load: Erosion Control w/Permit-Eng 05/29/2014 $75.00 Dwelling Units: 0 Stories: 0 Height: 0 ft Bedrooms: 0 Bathrooms: 0 Value: $3,000 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $194.33 Required: Required Items and Reports(Conditions) 1 Ersn Cntrl 503-639-4175 Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance • • k is suspended for more the 180 days. ATTEN . •r-.•- law requires you to follow the rules adopted by the Oregon Utility Notificati•• enter. Pose rules are set forth in OAR 952-001-1• 0 through OAR 952-111-009• You may obtain a copy of the rules or direct questions to OUNC by callin• 13.232.1987 or .:00.332.2344. Iss,ed By: ' Lag Permittee Signature:_ /`LLB' 19►_ Call 503.639.4175 by 7:00 a.m.for the next available I -•,ction date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. Building Permit Application Residential Ot FOR OFFICE USE ONL1 City of Tigard �1 � Da � Permit No.: j'4 . -`, • • • 13125 SW Hall Blvd.,Tigard,0 Plan Review i X99= Other Permit: Phone: 503.718.2439 Fax: 503. 960 Date/By: TI G A R D Inspection Line: 503.639.4175 9`l�1 Date Ready/By: / tuns: ® See Page 2 for Internet: www.tigard-or.gov MPS Notified/Method:'i/��y {�+ Supplemental Information TYPE OF �`��� 1 / f REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction 1:vl en Permit fees*are based on the value of the work performed. `I` Indicate the value(rotnded to the nearest dollar)of all ❑Addition/alteration/replacement • Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. gi 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 3po o.00 ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: ‘1900 St.„..) LSD,,.cf New dwelling area: square feet City/State/ZIP: j^t.C.4A4..O 1 00- 97t2.1 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Bs"-, I'a.R.;G^-c.0.J Covered porch area square feet Cross street/directions to job site: Deck area: square feet Other structure arca: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rowded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. �,,`-* --[� Valuation: $ OC r-No eaIcCti'C..i . 1 MSS : 4 kir o.k.( / 4W Jti_ 6. (� Existing building area square feet New building area: square feet M.PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: 2,•'?9 H S.- Sc.*rows ��,^„4.t,y j Occupancy groups: City/State/ZIP: f.trazt.A-x7 t 0e— Existing: Phone:(c171 )'2.0'1-2..71 C Fax:( ) _ New: ❑ APPLICANT a CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Structural plan review fee(or deposit): Contact name: mot; g%-".., FLS plan review fee(if applicable): Address: $C 9 Total fees due upon application: City/State/ZIP: Phone:(°171 )207 2 - 0'c Fax::( ) Amount received: E-mail: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name: en- Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: ip. q, ©o k )-5-1.1 Solar Installation Specialty Code checklist. City/State/ZIP: HI Ilblo om 0 R. G( -7 3 Permit Fee(includes plan revie $180.00 '\ 1,1 and administrative fees): Phone:(q7/ ,?.._,./(,, 0 so I Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: /Oe L.16) 7 4//15 Total fee due upon appication: $201.60 Autht5rized signature:Q . 2-Y'�t / This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Date: *Fee methodology set by Tri-County Building Industry Print name: �y�, g.,4,J 5 12`t I Z.ot'1, _ Service Board I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 4404613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONL1 City of Tigard Received II • 13125 SW HaII Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 Associated permits TIGARD 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical Internet: www.tigard-or.gov ❑ Other THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW l es No N/.. 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation.historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: . ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. _ ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must early original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore on and shall be shown to be a licable to the ro'ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"buildingplans will not be accepted. ❑ ❑ ❑ 26 "Reversed"buildingj,lans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ - including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits'BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT T I G A R D Building Permit Review — Commercial - With Land Use Building Permit #: 614Pa0141 -00 tf Site Address: ll id0 (R..) >f / r Suite/Bldg#: Project Name: dee& r4,4 cxsJ (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review Proposal: -A/O ,tom verify site address/suite #exists and active in permit system. Land Use Case#: 4/02.0-61-- crerpo F 'Plans Match Approved Land Use: ❑ Site Plan ❑ Landscape Plan ❑ Other. ❑ Urban Forestry Plan ❑ Elevation Plan ❑ Building Height: Maximum Height Actual Height ❑ Conditions Met: ❑ Prior to Submittal ❑ Prior to Permit Issuance Notes: Approved by Planning: ec..,49c-C Date: Revisions(after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal Original Submittal Date: N/A Site Plans: # Building Plans: # Building Permit#: ❑ Ent wilding permit bove. Workflow Routing 5nning ngineering t Coordinator butldang Workflow Sign-off: C7 Sign-off for Planning(include notes from planning review) Route Application Documents: le Building original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: rci,10 /7l ext l,/ By Permit Technician: J f Date: 5/27///1 1:\Building\Forms\BldgPermitRvw_COM_W ithLandUse_042914.docx Engineering Review ❑ Actual Slope: ❑ PH Permit#: ❑ Conditions Met Notes: /ao a e.A.0 a, . 1 S& 'J-G 3 Approved by Engineering: Date: Z ' ' --7 ,Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions Met-Prior to Issuance of Building Permit Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: 1.19K to Issue Permit / , ((((Approved by Permit Coordinator: • 0 Date: /)'%� t:\Building\Forms\BldgPermitRvw_COM_W ithLandUse_042914.docx - 7-a-6,Pc9-6/V—OO (g(7 ....,. ..... . . RECEWEP D Li .,. DESIGN GROUP INC. 9045 SW SWAP NW SOW 101 . .... MAY 2 9 2014 WOWS.OR 07210 (503)225-1679 CITY OF TIGARD "...!..,...... --)s BUILDING DIVISION Nap, i SW FONNER ST ..D__•... ,,____.,.2....._1. • .. ._ ____— • . . _ --- - -- - = ---"------7 --,;..=----.-;.7- — Z--. 1 I z t . • LOT 1 0 TREE PRESERVATION LEGEND I= a_ x EXISIING WC 10 IK ROPY. Cr < Z 0- 0 LVSRML DKr TO OE ITIORWEED L(dcl tC -.71.3.1fer. -41 tet W 0 > CC 11 * '' ... 52./ . .......--.... I * Ili I WS. ' WE WILE . .--7""a,Tioni : CC 0 W w 11. ct z a it flIff16•111111t1j1J,WML:u■ z LIJ VII•111MIWV,-4 MNIV,m ri.i.c.st=r110. o w 1 . LOT 2 El :4 ! SiM r0 aLrI2MllaJm R•11R 4■ =LA X I- e MUNI UleilliAlli WhntillIMMFLW.MMII6M •421 SWIM i%J..”./MOTI6M 11111111W3111 A-9-3Z-1-"-----1-71- In Atelq LOT 3 1 -fe.....1=117t,:t..,,,A1IFNIII ra463....WijaCillw I I REV. OS/S SY ... k, 0 Al ' I PROJECT 0260E0 119600i Ls. 01000. SYN. AS MOWN Cm* oRY CIT/ OF TIGARD Two.95 Pc • Approved ........ .. TREE PRESERVATION PLAN pproved by Planning 20'C. SCALE. r Date: 5-- ---1 C3.2 • ) Initial . / , Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 11400 SW FONNER ST, US Residential - Building 299 Final inspection PASS - No C of O BUP2014-00124 David Young Pump receipt received, tank removed from property per contractor Scott Hewett. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 11400 SW FONNER ST, US Residential - Building 299 Final inspection FAIL BUP2014-00124 David Young No one on site for inspection, no message left for contact. No pump and fill receipt for septic removal. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 11400 SW FONNER ST, US Residential - Building 299 Final inspection PASS - No C of O BUP2014-00124 David Young Pump receipt received, tank removed from property per contractor Scott Hewett. Violation Summary: Inspector Contractor