Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT ''1 • COMMUNITY DEVELOPMENT Permit#: FPS2014-00085 t G;A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/22/2014 -F Parcel: 1 S 135AB03400 Jurisdiction: Tigard Site address: 10260 SW GREENBURG RD 160 Project: Manpower Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Fire alarm for TI. Contractor: CAPITOL ELECTRIC CO INC Owner: LINCOLN CENTER LLC 11401 NE MARX STREET BY SHORENSTEIN PROPERTIES LLC PORTLAND, OR 97220 555 CALIFORNIA ST 49TH FL SAN FRANCISCO,CA 94104 PHONE: 503-255-9488 PHONE: FAX: 503-257-7121 FEES Description Date Amount Specifics: Permit Fee-COM 05/22/2014 $102.20 12%State Surcharge-Building 05/22/2014 $12.26 Type of Use: COM Plan Review-Fire Life Safety-COM 05/22/2014 $40.88 Class of Work: ALT Type of Const: IIB Info Process/Archiving-Lg$2.00(over 05/22/2014 $8.00 Occupancy Grp: B Height: ft 11x17) Stories: 12 Info Process/Archiving-Sm$0.50(up to 05/22/2014 $5.00 11x17) Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Yes Alarm Type: Automatic Pull Station Required: Yes Smoke Detectors Req: Yes Battery Calcs Provided: Yes Cut Sheets Required: Yes Total $168.34 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $2,100.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-0 90. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: ✓ Permittee Signature: Ca 43.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD ELECTRICAL RESTRICTED ENERGY PERMIT si `�1 • COMMUNITY DEVELOPMENT Permit#: ELR2014-00112 Tr G AR O 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/22/2014 Parcel: 1 S135AB03400 Jurisdiction: Tigard Site address: 10260 SW GREENBURG RD 160 Project: Manpower Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Low voltage for fire alarm. Contractor: CAPITOL ELECTRIC CO INC Owner: LINCOLN CENTER LLC 11401 NE MARX STREET BY SHORENSTEIN PROPERTIES LLC PORTLAND, OR 97220 555 CALIFORNIA ST 49TH FL SAN FRANCISCO, CA 94104 PHONE: 503-255-9488 PHONE: FAX: 503-257-7121 FEES Description Date Amount Specifics: Restricted Energy Permit 05/22/2014 $75.00 12%State Surcharge-Electrical 05/22/2014 $9.00 Type of Use: COM Class of Work: ALT Total Number of Systems: 1 Audio&Stereo: 0 Boiler Controls: 0 CCTV: 0 Clock Systems: 0 Data&Telecommunications: 0 Fire Alarm: 1 HVAC: 0 Instrumentation: 0 Intercom/Paging: 0 Landscape/Irrigation: 0 Landscape Lighting: 0 Medical: 0 Nurse Calls: 0 Protective Signal: 0 Security Alarm: 0 Other: 0 Total $84.00 Other Desc: Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Ce er. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a cop fse rules or direct questions to OUNC by calling 50 7 or 1.800.332.2344 J I/ Issued By: — Permittee Signature: OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE: Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application RECEIVED , Fire Protection System RECEIVEP FOR OFFICE USE ONLY- City of Tigard MAY 12 2014 Da eked /2 �at' Permit No !S QoOps' - • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Revie.��j r tu�/y OO /' Phone: 503.718.2439 Fax: 503.598.1960 Date/B : r . Other Perini TIGARD Inspection Line: 503.639.4175 CITY OFTIGARD Date Ready E3 See Page 2 for Internet: www.tigard-or.gov Notified/Method: y J AM.= Supplemental Information BUILDING DIVISION e9 p o-LtAJ TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING Q ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Ct. Indicate the value(rounded to the nearest dollar)of all O ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:10260 SW Greenburg Rd Tigard,OR(Lincoln Twr) New dwelling area: square feet City/State/ZIP:97223 Garage/carport area: square feet Suite/bldg./apt.no.:Ste 160 Project name:Manpower T.I. Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Install fire alarm devices per plans Valuation: $2,100.00 Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Shorenstein Realty Services Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: ❑ APPLICANT ❑ CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons apply: Phone:( ) Fax::( ) E-mail: CONTRACTOR BUILDING PERMIT FEES* Business name:Capitol Electric Company,Inc. (Please refer ro fee schedule) Permit fee: 102.20 Address:11401 NE Marx Street City/State/ZIP:Portland,OR 97220 — State surcharge(12%of permit fee): 12.26 FLS plan review(40%of permit fee): Phone:(530)255-9488 Fax:(503)255-1966 (Due upon application.) 40.88 CCB lic.:48748 Total permit fees: 155.34 Authorized signature: (-9'Ark......„...- Amount received: This permit application expires if a permit is not obtained Print name:Dan Wilson Date:5/9/2014 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Pemlits\FPS-PermitApp.doc Rev 01/05/2012 440-4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only ❑ Addition ❑ 1-10 heads: No plan review required. ❑ Alteration ❑ 11+heads: Plan review required. El Repair Number of sprinkler heads: Additional description of work Type of System(Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K.Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ® Yes include: Individual Component ® Yes Cut Sheets Fire Alarm Project Valuation: $ 600.00 D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B &C above): $ 2,100.00 Permit fee based on project valuation(see fee schedule): $ 102.20 Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ 12.26 FLS Plan Review(40% of permit fee): $ 40.88 TOTAL: $ 155.34 Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. U:\FA Jobs\zz140879-45 Manpower T.I. LT-160\1 FPS-PemutApp.doc Rev 01/05/2012 Electrical Permit Application RECEIVER FUR 0,,, i( I: I SL O\1.1 Received City of Tigard Date/By:S//Ji�Y Pemttt no�L/J !2 �1�DD//�7 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 1 2 2014 Plan Review /� °�fJ t�- C Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit��s-�/y-0 0 0 c5 TIGARD Inspection Line: 503.639.4175 Date Ready/By: Juris: ��� Internet: www.tigard-or.gov CITY OF TIGARD % See Supplemental 2 for Notified/Method: / Supplemental lnfortnation TYPE OF WORK PLAN REVIEW ❑ New construction U Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked below): ❑ Demolition ❑ Other: ❑ Service or feeder 400 amps or more ❑Building over three stories CATEGORY OF CONSTRUCTION where the available fault current ❑Marinas and boatyards Li 1-and 2-family dwelling U Commercial/industrial U Accessory building exceeds 10,000 amps at 150 volts or Floating buildings ❑ Multi-family ❑ Master Builder ❑Other less to ground,or exceeds 14,000 Commercial-use agricultural JOB SITE INFORMATION AND LOCATION amps for all other installations. ❑ buildings Job no.: 140879-45 Job site address: 10260 SW Greenburg Road ❑ Fire Pump ❑ Installation of 75 KVA or ❑ Emergency system larger separately derived system. City/State/ZIP: Tigard,OR 97223 ❑Addition of new motor load of CI^A-,"E","1-2","1-3", 100HP or more. ❑ occupancy Suite/bldg./apt.no.: Ste 160 Project name: Manpower T.I. ❑ Six or more residential units ❑ Recreational vehicle parks. ❑ Health-care facilities ❑ Supply voltage for more than Cross Street/Directions to job site: ❑ Hazardous locations ❑ 600 volts nominal. ❑ Service or feeder 600 amps or more Subdivision: Lot no.: FEE SCHEDULE Description I Qty. I Fee. I Total I •. Tax map/parcel no.: New residential-single or multi-family dwelling unit. DESCRIPTION OF WORK Includes attached garage. INSTALL FIRE ALARM CIRCUIT 1000 sq.ft.or less $ 168.54 4 Ea.Add'l 500 sq.ft or portion $ 33.92 I U PROPERTY OWNER I ❑ TENANT Limited energy residential Name: (with above sq.ft.) S 67.84 2 SHORENSTEIN REALTY SERVICES Limited energy,multi-family Address: residential(with above sq.ft.) $ 67.84_ _ 2 Service or feeders installation,alteration,and/or relocation City/State/ZIP: 200 amps or less $ 100.70 2 201 amps to 400 amps $ 133.56 2 Phone: Fax: 401 amps to 600 amps $ 200.34 2 _ 601 amps to 1000 amps $ 301.04 2 Owner installation: This installation is being made on property that I own which is not Over 1000 amps or volts 5 552.26 2 intended for sale,lease,rent or exchange,according to ORS 447,449,670,and 701 Temporary services or feeders installation,alteration,and/or Owner signature: Date: relocation 200 amps or less $ 59.36 1 Li APPLICANT I ❑ CONTACT PERSON 201 amps to 400 amps 5 125.08 2 Business Name: 401 amps to 599 amps $ 168.54 2 Branch circuits-new,alteration,or extension,per panel Contact name: A. Fee for branch circuits with service or feeder fee,each Address: branch circuit 5 7.42 2 B. Fee for branch circuits City/State/ZIP: without service or feeder fee, first branch circuit 5 56.18 2 Phone: Fax: Each additional branch circuit: $ 7.42 2 Miscellaneous(service or feeder not included) E-mail: Each manufactured or modular CONTRACTOR dwelling,service and or feeder 5 67.84 2 Business Name: CAPITOL ELECTRIC CO.,INC. Reconnect only $ 67.84 2 Pump or irrigation circle $ 67.84 2 Contact name: DAN WILSON 503.262.0411 DIRECT Sign or outline lighting $ 67.84 2 Signal circuit(s)or limited- energy 11401 NE MARX ST. energy panel,alterations,or extension. Describe: Fire Alarm 1 Page 2 S 75.00 2 City/State/ZIP: PORTLAND,OR 97220-1041 Each additional inspection over allowable in any of the above Phone: 503-255-9488 Fax: 503-257-7121 Per inspection $ 66.25 Investigation per hour(I hr min) $ 66.25 CCB Lic.: 48748 'Electrical Lic.: 26-496C ISuprv.Lic.: 3132-S Industrial plant per hour $ 78.18 Suprv.Electrician signature,required: '/ 1/11 _) ELECTRICAL PERMIT FEES* Subtotal $ 75.00 Print Name: DAIRELL MCNEEL Date: 109/ Plan review(25%of permit fee) Authorized signature: /� hy,' State surcharge( 12% of permit fee) $ 9.00 TOTAL PERMIT FEE $ 84.00 Print Name: DARRELL C EEL This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Number of inspections per permit allowed. Capitol RECEIVED Electric Co., Inc. MAY 12 2014 CITY OF TIGARD BUILDING DIVISION May 9, 2014 Plans Examiner City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Tenant Fire Alarm System Additions Manpower T.I., Suite 160 @ Lincoln Tower 10260 SW Greenburg Road Tigard, OR 97223 Please find attached building and electrical permit applications,three sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. Occupancy Group: B,High Rise The fire alarm system design includes the following: 1. Install ADA synchronized fire alarm notification devices in the tenant space including(7) strobes. 2. We will pre-test the fire alarm devices prior to requesting a final fire alarm inspection. 3. Fire alarm design by Simplex-Grinnell, installation by Capitol Electric Co. Please contact me if you have questions or comments. Respectfully, Dan Wilson, SET Project Manager/Estimator Fire/Life Safety Division Capitol Electric Company, Inc. (503) 262-0411 Direct dan @cepdx.com NICET Level IV, Fire Alarm Systems #104512 11401 NE Marx • Portland, Oregon 97220-1041 • 503-255-9488 • Fax 503-257-7121 CCB# 48748 • www.capitolelectricco.com Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10260 SW GREENBURG RD 160, TIGARD, OR, 97223 Commercial - Fire Protection System 998 Alarm Final PASS - No C of O May 30, 2014 at 10:14:46 AM FPS2014-00085 Chip Barnett Violation Summary: Inspector Contractor