Correspondence (2) MACKENZIE /SAITO & ASSOCIATES, P.C. ARCHITECTURE • PLANNING • INTERIOR DESIGN 0690 S.W. BANCROFT STREET • P. O. BOX 69039 PORTLAND, OREGON 97201 -0039 • (503) 224-9570 • FAX (503) 228 -1285 • MEETING MINUTES z34, Z Vo DATE: ch 13 • • ( t;, 57) i&' SUBJECT: PacTrust Corporate Center Building 240/241 C Stair #3 Construction and Elevator Lobby Doors Meeting Minutes (36/95) Pac Tru s t ``�- M ` Project Number 294048.07 J r '�DA BY: Dennis Woods !� PRESENT: Dave Scott, Building Official - City of Tigard Ken Grimes, Dick Krippaehne - PacTrust Dennis Woods - Mackenzie /Saito & Associates (MSA) The following items were discussed: 1. Dave Scott requested the following in order to maintain open stair #3 at the lobby of the first and second floors: a. The underside of stair stringers/landings and all wall surfaces around the stair are to have one layer of Type X rock (each side at walls). In addition, the stair stringers between the second and third floor are to have a one -hour, horizontal shaft liner. b. The stair at the third floor and the second floor between the first and second floors is to be enclosed with a one -hour door with smoke gaskets. c. All elevator lobby doors on all floors are to be tied together on a magnetic hold open - -if one closes, they all close. The elevator lobby magnetic hold open is to be tied to the corridor and tenant alarm system for each floor. 2. With the above -noted conditions, all other door and glass openings into this area can be treated as noted in the previously approved alternate design (i.e., additional sprinkler heads, smoke detection, and alarm system). 3. Dave asked that we resubmit the revisions as discussed and that all revisions be on large sheets (no 8 -1/2 x 11's). Every effort has been made to accurately record this meeting. If any errors or omissions are noted, please provide written response within five days of receipt. DRW /sk c: All Present MACKENZIE/SAITO & ASSOCIATES F:IWPDATA\95 -03\94048.071I3MM.SK ' OCT -12 -95 THU 14:53 MSA /MEI FAX NO. 5032749812 P.05 Y REnEFIWIE1 .` M`;'' cirri OF TIGARD March 10, 1995 Mackcn? 1,.,zto $, A:,rn:iates OREGON Mackenzie Engineering Incarpoiated Mr. Dennis Woods Mackenzie Saito and Associates 695 SW Bancroft St Portland, OR 97201 -0039 Re: Stairway enclosure modification for Bldg. 240 (BUP 94 -0300) and Bldg. 241 (BUR 94- 0301). Dear Mr. Woods: The letter serves to document the modification to the stair enclosure requirements of Sec. 3309(a) of the Oregon Structural Specialty Code discussed at our meeting on March 6, 1995, and to clarify Item #3 of my letter dated February 16, 1995, regarding the modification to the opening protection requirements for the corridors by specifying how the smoke detection /alarm system for the building will operate. 1) A modification is granted to permit the central stairway to have unprotected openings at the first floor (bottom of stair flight to second floor) and second floor (bottom of stair flight to third floor), subject to the following conditions: a) The openings into the stairway at the top of these stair flights shall be protected by one -hour rated, smoke gasketed doors provided pursuant to Sections 3309(c) and 3305(h). b) All automatic closing elevator lobby doors on all floors shall close upon activation of any one automatic closing elevator lobby door. c) The stairway between the second and third floors shall be completely separated from the stairway between the first and second floors by one - hour construction and the doors described in item (a) above. The use of one -hour shaft walls at the underside of a flight is permitted (see attached drawing), 2) The following will summarize the requirements for the smoke detection\alarm system required pursuant to item #3 of my letter dated February 16, 1995, and item (1)(b) above: 1;31 5 SW 4 r Il Rk ,rl TIi+..r.rJ (113 C7 icno% •• .9 • . _ . • OCT - 12 - 95 THU 14;54 NSA /l1E I FAX NO. 5032749812 P.08 Mr. Dennis Woods - Letter March 10, 1995 Page 2 a) All corridors and elevator lobbies shall be provided with automatic smoke detectors located pursuant to tho Uniform Fire Coda and Standards. U) When a smoke detector on a given floor is activatod, alarms located in all common areas of the tenant areas (Including the building confcronce room) and building restrooms shall annunciate on that floor. c) When any automatic closing elevator lobby door in the building is activated, all automatic closing elevator lobby doors In the building shall activate, and the alarms on the floor where the first elevator lobby door was activated shall annunciate. All conditions of my lotter dated February 16, 1995, remain in effect. Please call If you have any quest' ns. Sincerely, . ri • David Scott, P.E. Building Official c: Ken Grimes, PacTrust Tom Plescher File , • • COT-12-95 THU 14:52 MSA /NEI FAX NO, 5032749812 P.03 o CITY OF TIGARD OREGON February 16, 1995 • . I Dennis Woods Mackenzie Saito and Associates 0690 SW Bancroft St. P.O. sox 69039 Portland, OR 97201 -0039 Re: r on Modificati to cor: requirements on for dor and elevator lobby opening protection central core corridors, Job; Pacific Corporate Center Bldg. 240 BUP94 -0300 Pursuant to your request, a modification of Sections 3305(h) and (j) is granted to permit the use of non -rated door and side light assemblies for suite entrances from the core corridors and elevator lobbies. These sections require that such doors be tight - fitting smoke and draft control assemblies having a fire-protection rating of not less than 2 0 - minutes and side lights be fixed glazing listed and labeled for a f' P= otected by fixed e three - fourths hour. This approvalis to at I the ° following conditions: 1� All non -rated doors shall be provided with a ti-fitting smoke gasket assembly and be protected ck-r soue sprinklers on both sides of the opening. by quick- eFoZSe 2. All non - rated side lights shall and be protected by y be 1/4" thick tempered glass and bprotected y quick- response sprinklers on both sides of opening. (Note: if a combination door /side light assembly is no wider than 6' -0 °, one head will suffice at each side, otherwise two heads at each side will be required. 3 • All core corridors and elevator lobbies shall be provided with a smoke detection system which shall annunciate both visual and audible alarms installed throughout the building in conformance with the Fire Code and Chapter 31 of the Oregon Structural Specialty Code. • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 T00 (503) 684 -2772 OCT -12 -95 THU 14 :53 t1SA /I1E 1 FAX NO. 5032749812 P. 04 • . . 4. Openings into the core corridors and elevator lobbies from tenant spar.Ps shall be limited to the subiect entry doers and side lights. Each tenant will need to incorporate these conditions into their fire protection Systems. Please call if I can be of any further assistance. Sincerely, _/ � • / /1 • • �. i. David Scott, P.E. Building Officio] CC: file Pectr st (Attn: Ken Grimes) Tom Plescher Tualatin Valley Fire and Rescue •