Specifications (2) 7/17/13 TGFU.Guidelnfo-Roofing Systems • Combustible Deck Construction: 1. Insulated roof systems certified for use over combustible deck can be used over any type of existing roof system and maintain its new construction rating. 2. Insulated roof systems certified for use over noncombustible deck may be used over any type of Class A, B or C existing roof systems. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. 3. Uninsulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating. 4. Spray applied foam systems with minimum 1-1/2-in.-thick foam certified for use over noncombustible deck may be used over any type of Class A, B or C existing roof system. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. SINGLE-PLY MEMBRANE SYSTEMS (INCLUDES MODIFIED BITUMEN MEMBRANES) These roofing systems are composed of various types of membranes (such as EPDM, PVC, CSPE and modified bitumen) which are either ballasted, fully adhered or mechanically attached. Certified insulation may be utilized, as well as various coatings, splicing adhesives, lap sealants and caulking materials. See the individual certifications for designations of products and application rates for various components. Unless otherwise required, granules or sand may be optionally applied to any coating. SPRAY-APPLIED FOAM AND COATING SYSTEMS These roofing systems are composed of a foam, formed by the simultaneous spraying of two liquid components to a nominal thickness, covered with a cold-application coating system to form a protective covering. Surfacing materials, such as sand or No. 11 roofing granules, may be embedded in the coating while wet. See the individual certifications for designation of products, foam thickness and application rates for the coatings involved. Unless otherwise required, granules or sand may be optionally applied to any coating. PHOTOVOLTAIC(SOLAR)MODULES Photovoltaic(solar) modules are composed of flat-plate photovoltaic module/panels when installed in accordance with the manufacturer's installation instructions. These coverings have also been investigated to ANSI/1.11, 1 7 0 3, "Flat-Plate Photovoltaic Modules and Panels"; see Photovoltaic Modules and Panels (QIGU). OTHER SYSTEMS These systems cover products such as building units used in specific Class A, B or C roofing systems. Building units may consist of composite insulation boards, metal-faced insulation panels or insulating material, faced on top and bottom with metal or plastic reinforced glass fiber skins which are intended for direct application to rafters or puffins. The structural aspects of these materials have not been investigated. See the individual certifications for the specific system details. ABBREVIATIONS AND TERMS USED IN CERTIFIED ROOFING SYSTEMS DESCRIBED FOR INDIVIDUAL MANUFACTURERS Decks-Noncombustible = NC;combustible(includes noncombustible)= C. (Suffix number indicates the minimum thickness of plywood). Maximum incline in inches to the horizontal foot = Incline, "x"(in.). Inclines sufficient to permit drainage = Incline-no limitation. Per 100 square feet = Per sq. Application rates for mineral surfacings and liquid components shall be a number indicating either lbs or gals per square. Minimum surfacings in a flood coat of hot roofing asphalt or coal tar pitch: • 400 lbs gravel per square= gravel • 400 lbs crushed stone per square=crushed stone • 300 lbs slag per square= slag Application rates differing from the above are indicated in the individual certifications. Any other surfacing materials used are described on individual certifications with type and application rates specified. Where indicated in the individual certifications, products covered under this category have also been evaluated by ICC Evaluation Service (ICC-ES). PRODUCT IDENTITY One of the following product identities may appear on the product: Base/Ply Sheet for Roofing Systems Building Units for Roofing Systems Cements and Coatings for Roofing Systems database.ul.comfcgi-bin/XYV/template/LISEXT/1FRAME/sho.page.html?&name=TGFU.Guidelnfo&ccnshorttitle=Roofing+Systems&c*id=1074351572&cfgid=... 5/7 T/17/13 TGFU.Guidelnfo-Roofing Systems Flashing Material for Roofing Systems Foamed Plastic for Roofing Systems Foamed Plastic Ingredient for Roofing Systems Hold-down Device for Roofing Systems Insulation Adhesive for Roofing Systems Insulation Joint Tape for Roofing Systems Membrane for Roofing Systems Membrane Splicing Tape for Roofing Systems Mineral and Fiber Board for Roofing Systems Slip Sheet for Roofing Systems Tiles for Roofing Systems Type 15 Saturated Felt, Cap or Base/Ply Sheet for Roofing Systems Type 30 Saturated Felt, Cap or Base/Ply Sheet for Roofing Systems Type G1 Coated Base/Ply Sheet for Roofing Systems Type G2 Coated Cap or Base/Ply Sheet for Roofing Systems Type G3 Mineral-surfaced Base/Cap Sheet for Roofing Systems ADDITIONAL INFORMATION For additional information, see Roof-covering Materials (TEVT) and Roofing Materials and Systems (AARM). REQUIREMENTS The basic standard used to investigate products in this category is ANSI/UL 790, "Tests for Fire Resistance of Roof Covering Materials." Some of the products specified in these systems are covered in UL 55A, "Materials for Built-Up Roof Coverings." UL MARK Two methods of labeling are provided for this material: (1) Each bundle, package or container bears the Certification Mark, and (2) a Certificate is issued to the interested parties. This Certificate is prepared for each construction site that the manufacturer supplies. The use of the Certificate is optional when each bundle, package or container bears the Certification Mark but, in all cases, is restricted to material shipped directly from the manufacturer to a construction site. The Certification Mark of UL on the bundle, package or container is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number. Additional Certification Markings Products covered under this category are additionally marked with the following information: CERTIFIED AS TO EXTERNAL FIRE EXPOSURE The following statement may be included where appropriate: ALSO CERTIFIED AS TO IMPACT RESISTANCE SEE UL ONLINE CERTIFICATIONS DIRECTORY Alternate UL Mark Two methods of labeling are provided for this material: (1) Each bundle, package or container bears the Classification Mark, (2) a Certificate is issued to the interested parties. This Certificate is prepared for each construction site that the manufacturer supplies. The use of the Certificate is optional when each bundle, package or container bears the Classification Mark but, in all cases, is restricted to material shipped directly from the manufacturer to a construction site. The Classification Mark of UL on the bundle, package or container is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information: + FOR ROOFING SYSTEMS AS TO EXTERNAL FIRE EXPOSURE Control No. + One of the following designations: database.ul.comlcgi-bin/XYV/template/LISEXT/1FRAME/shci page.htn-1?&name=TGFU.Guidelnfo&ccnshort tle=Roofing+Systems&obiid=1074351572&cfgid=... 6/7 7/17/13 TGFU.Guidelnfo-Roofing Systems • 1. CEMENTS AND COATINGS 2. TYPE 15 SATURATED FELT, CAP OR BASE/PLY SHEET 3. TYPE 30 SATURATED FELT,CAP OR BASE/PLY SHEET 4. TYPE G1 COATED BASE/PLY SHEET 5. TYPE G2 COATED CAP OR BASE/PLY SHEET 6. TYPE G3(optional COATED)MINERAL SURFACED BASE/CAP SHEET 7. MINERAL AND FIBER BOARD 8. FOAMED PLASTIC 9. TILES 10. BUILDING UNITS 11. MEMBRANE 12. FLASHING MATERIAL 13. FOAMED PLASTIC INGREDIENT 14. BASE/PLY SHEET 15. SUP SHEET 16. HOLD DOWN DEVICE 17. MEMBRANE SPLICING TAPE 18. INSULATION JOINT TAPE 19. INSULATION ADHESIVE As appropriate, the statement ALSO CLASSIFIED AS TO IMPACT RESISTANCE(SEE ROOFING MATERIALS AND SYSTEMS DIRECTORY) may also be included. **** * *** * * * * * * * * * * * * ** * ** UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information. Last Undated on 2013-05-16 Questions? Print this page Terms of Use Page Top © 2013 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2013 UL LLC". database.ul.corr✓cgi-bin/XYV/ternplate/LISEXT/1 FRAME/showpage.htnl7&name=TGFU.Guidelnfo&ccnshorttitle=Roofing+Systems&objid 1074351572&cfgid=... 7/7