Specifications (2) k :k �„ Matchless Energy Management, Inc. ,,i?Eket' 50/ 4, .�, 0 ,f.. 1 Ji l6,4a "11P jW) S Clii ' ` A PO Box 6073 - Parsippany - =` NJ 07054 973- 335 -5885 1 ' March 5, 2010 T• 7 } .t Mr. Jess Wetsel The Wetsel Company Jess(a�wetsel.net JUN 0 4 2010 2123 NW Aloclek Drive - Suite 1203 i Hillsboro, Oregon 97124 1 CTY I ARD i BUILDING DIVISION Subject: Sonic 6206 - Canopy Heating Equipment We are pleased to offer the following pricing covering Superior Radiant Products Two Stage Gas Fired Radiant Tube Heaters for outdoor canopy installation as shown on our proposal drawing. Chain hanging ' sets are in the base pricing together with a stainless steel flexible gas connector and a ball valve for each heater. Base pricing also includes rotary timer, control switch and two built in isolation relays for '+i P 9 rY y switching heaters between off, high and low output levels. Decorative /protective grille pricing is offered • t as an option. Purchaser is to furnish canopy structure attachment hardware to connect chain to canopy. 1. �� We offer the following: Base Price ,� l r' t{1 11 j. i' r I L_ .* 1 , .. , ! 2 - TXR1ON2A Two- Stage Gas Radiant Tube Heater (20' Tube Length - 100/75 MBH) ,I,It f,,� '' ` �' ;' G Heaters are Series TXR, built for installation in harsh environment �� t1, , i' tii ,,N-L o All heat treated aluminized steel radiant tube (10 year warranty) !� III : !,� 0 Stainless steel flex gas connector, AGA ball valve , t Q Heater chain hanging sets included C ) o Rotary control timer, DPDT selector switch, 24v hub mount control transformer o Air intake hood with bird screen, vent discharge with bird screen " I; o Built in control circuit isolation relays '% Lot: $ 2,535.00 1 g F,x. Optional Equipment .•, P s CR051 -4 Sets (2) decorative /protective screen for 20' long heater assembly. $ 585.00 ;, - CR165 Sets (2) seismic /wind bracing hardware (where required) 90.00 o f Prices offered are subject to change without notice. Prices are fob point of shipment, normal freight - (1 charges generally range from $200 to $350 nationwide for shipping this package of equipment. Terms of I 1 !' payment to be arranged. Any sales or use tax applicable to the above outlined equipment is to be paid by !, the purchaser to the authority having jurisdiction. I We hope that the information furnished is satisfactory and look forward to working with you toward the successful application of our equipment. Please do not hesitate to contact us if you have any question. Respectfully submitted, Matchless Energy Management, Inc. hl John P. Gra T4 r jgrant@matchless-energy.com 5.15.0.. * / 1 . . . E. ViNv SRN Vvrtv • : •c ; - 1 -- i SERIES TXR - TVVO STAGE HEATER WI . . . ,.... ..z .z... .., 1 _ t CND** XX1,4DR,DROX , . . " , - I. - _, Coda. Pam PaSizePS).*AersCavectd Vetateatenj , Heaa Psi. , - ,. .n., 1 - _rotaGerris IIIME I ligt---M.----'' live.. r LI ft r® 1.25CD - • - --. --- --- . .... hs.eiGalrbN N Q) N CID ' Pgre il I ci l@ N CD . . .■ . f-,:-.140•00...,=, • 1 : se serass*s........6* 404c7Al21 01314,2,0 00100m00000,01000 00,0010,00100011 ,. - SteGssite &Ng &Wile 1 1 ..c........slo MS Its. ES.000.. 5 IN 6.5.100.0.115521•. ..•65.51.N.A. 105510.0.0.06.1611,....0 to --• - ..,.77.:- GAS PIPE SIZING SCHEDULE • _ 1.-.. TWO STAGE HEATER ,..../ r , . - ■• - - - - 1 . —. -1- • r IL I 1 !■ a-- -.,---, • I • ii - :'.--, 'Th _., ..._;,_=,______,:,..„ • - .:-.*--.-...,,,,..., , ____,-„,,,,,.. a -.,_ I _ . ill • .• ..: _ " • A - 1 i 1 " ' . ..1 • ..... : • ''''''' '''' •-• '''' ''' - •-•'' - ...:1] H.i . - , 7.1. ... -.... . I ' - 1 — -' .... 5 F...s.,.......... i I .— — .,1____-_ ___i 4_ _ 1 __ GIs.. VASS. • 5 ASO I ..... . — -- MI MI = = ME la 0 !WALLA.. NOTES: OAS.. TO RE 6C1110. 0 A-53 BLACK PPE WELOED OR I AS RIMMED SYLITILITY. Scale: 1/4 ALL 0110143 900“. BE MALLEABLE RON; MO BMW. PERVOITO. STANDARD MON IMMURE ' 1 lh llIl . ' ' H' AK TM -MtEbSUPE MO 00.00. A5 01.71,0E7 0 11,1,64. acme.. sow.‘ BF ItAfORLIED . TOT. SATMACTON OF 111E 4.-ITY Oa ME AOMORI, NAV. A0110ICTION BUMF 'WEL IS MIE L l=077117. 1 2. Or, tiaTACT CY1 =0 lar041 1 ••• 1 ' ' .. ' ' • 1. ■ ...-- .■ ' 1 A 10,6 Pl110.010. MEAR TV WAXER LOCATION FAIM.811,051 10F 04.5 SERVICE ENTRANCE 70 i AC11.0 ATE CMEC1000 0 NOUSE 049100000/10AS MESSURE. 6,00,030 611. ,V.700kf 00.10100,700 61041.00 01'1.A100 ACTA. WV. USW FOP CONX,C1.0 KM. TO ME OAS..., SEE KV. ACTUREP1 SPECIFIC WSTINCTIO. IN MI5 RE0.0. ' Illonra.2.1=42.174MENOVITMEt. E.PUTIPI-41° 23 OP MAY.. 001.1. l0C3,10 CONK.. POWS. MONO.5117SMIC IMACSO IBA DMZ . As RE0.10..SEEPROACT DC...TS. SUPERIOR RADIANT PRODUCTS OV I , - 3 PROVIOECA.0140011 LOCAL ELECTOCAL 0111COMM A T EACH APPLIANCE TWO STAGE GAS RED RADIANT TUSE XEAM5 I i....... _...... . 1 4 WSTAL4TION MC0001110 TO 711E 7015 ON9MOCIION CODE.LATEST EOM. A5 WELL AS , 73-baSk ananiaokrs ii ', ' .'{. - - ' q .. ' ' I NrAVVIMISTUSSCIAT.V.XLMOITreatrAMMEWOZgs% grs 1_ 1..... 4.,.. NS LOVE1000,11.5 TYPE OF IMIALLATIOW . .. I I ' 5. 51•110N55 ALL MOUSED CLEM/ISM 0.11.7.0 ON ME EOMPIWNT DATA KAT. SE ME rSZT J0.91VEYOVAraarlr.,71■Wellral".Err&TRTNEWO:r"-' — • -- 4 C •510.2010s WTI INSTALLATIC0. MERE ANY DISCREPANCV IOAT MST BETWEEN INFORIMPON ,,,,,r,,, ;VS ,..., PIESEATE0 OM MIS ORA.. ANO ME muurAcrumrs Namcnc.n.i.xvrAcTuRE” WSTROCTIONS SMALL TAKE NIELEDENCE 6. 50.105E IIIE O. SUM, MUMS MEM I! WC... MUTER MALL BE MANED WIM • 1243-10 SIMONE RESAATOR RAMISNEOWIM• VOIT LK.. CESCE AMP NET TO 7' WC - M TWO STAGE GAS RADIANT HEATING Matchless Energy Management, Inc. (.4..--,.„, TIGARD, OREGON SONIC RESTAUARANTS i Parsippany, New Jersey Its1;t., J z TWO HEATER ARRANGEMENT As Noted March 5, 2010 973-335-5885 6206 CANOPY HEATING Scale: ',..`"rin 2 I hi i' � t q t . '„: .„---' -,,,,, „:4 „„ 1. r' � � to {P „ . „, ,1 , i t 1 .,, „::: „..„„ ,, ,,, :, ,,, yy � :45 - jF..�, ��r .."'5'1, �� F �� t � � , L '� r L � S� `� ( yt D ` x t � � o� � k :, d �.1 � _ ' "v 7 ti s c � r i r . ,c '` uy a "'� kl �` "Sr , d b , n , � h i #la#'YHIIIGA'Kk1frLM� TY Cw. kW�i�1i�" i�Yf15r,SMUr4s@!4t'"'�'".`1"F�I I t[ 1 N € j ;i1, SO NIC CORPORATION 11 % OKLAHOMA CITY, OKLAHOMA hl Iv 1 '} ) TWO STAGE GAS RADIANT TUBE 1 k I`' , CANOPY HEATING , 1'1' '1 THE WETSEL COMPANY 1 ; ' 1 I . h HILLSBORO, OREGON 3 , j SONIC — 6206 ? 1 1 TIGARD OREGON �' di INSTALLATION NOTES i 11 March 5, 2010 1 r hil M h11 ' h, Matchless Energy Management, Inc. { 11, 1 �fl Parsippany, New Jersey ' 2 1' '± ��� 973 - 335 -5885 1[ • • • d j gran t a matchless- energY.com f j p : 1 h . 4; i y {{ r1 �`JJ9�4i1J` ` l Alt 1,,,,,.. _ I I 1 , - 3 "' I } f ` 1 . •`i F { - -.''" fi ,. 1 � 2 �;' �. t ar l',,:%; .1tf :t , Y h 1. � _ 's �` $ vw. d � !" .a ��� i' J cif it' . ,� i • p h.• k (� , g ' /�'�� 1 e 1 6v \ Y �e r" » } ah " k 4 " . _,/ I"�., _ " '' n� d t,.�' k " ` it F 7n , '. . • . 4 1 . a • ,P c i , ,___,„ ,, ,;,. ..,-. .,..,;.,..,,:,-.. .r - .1 1.( 1 F fT i ° Rates 40,000 to 220,000 BTU /HR ° 24v direct wire for Thermostat o Natural Gas and LPG ° Hinged service cover on TA o Configurations of U and L 0 Jet Stream Burner - horizontal or 45° o Separated Controls Compartment - improved heat distribution - electronics out of air stream - better combustion - burner can run during servicing ° Heavy Duty Couplings o Self diagnostic ignition module - no leaks o Parabolic Aluminum Reflectors - cannot be over tightened - most efficient in the industry • Direct Spark Ignition 0 TX Burner Housing is totally enclosed °Vented or unvented ° 10 year warranty on optional ° Operating status lights aluminized heat exchanger Ain pESIGN A RADIANT PRODUCM ,; sUPERIO '.f N LOG S UPS ' o R ip„ERFOn , ..TE • CER71FlEp i? f � l i .. S enes TA an . . : ,i;. S b P J -•y -x _ u.7 MODEL RATE BTU /HR SHIP WT. STD. LENGTH Nat. Gas. High Low ELECTRICAL RATING GAS CONNECTION TA (X) -40 40,000 30,000 80 Ibs (37 kg) 10 120 VAC 60 Hz 1A 1/2" NPT TA (X) -60 60,000 45,000 120 Ibs (55 kg) 20 plug connector TA (X) -80 80,000 60,000 120 Ibs (55 kg) 20 Extension TA (X) -100 100,000 75,000 120 Ibs (55 kg) 20 Options TA (X) -125 125,000 95,000 160 Ibs (73 kg) 30 Available TUBE DIAMETER MINIMUM GAS INLET TA (X) -150 150,000 115,000 200 Ibs (91 kg) 40 " W.C. TA (X) -175 175,000 130,000 240 Ibs (109 kg) 50 Flue 4" LPG gas Combustion air 4" Nat gas 5.0 5.0 W.C. TA (X) -205 205,000 160,000 280 Ibs (127 kg) 50 TA (X) -220 220,000 165,000 280 Ibs (127 kg) 60 STANDARD EQUIPMENT INCLUDES OPTIONAL EQUIPMENT • Burner housing assembly • U or L bends for specific layouts • Aluminized combustion tube with gasket • Side reflector and brackets • Combustion air inlet collar • Lower shield and brackets • Turbulators when required • Thermostat - 24v • All tube, reflectors, coupling and hanging accessories • Termination vent per specified length • Hot rolled or aluminized tube END SIDE TOP 18 " T I" . rm.,,,H_... _-.-) 4 .. — I < 9 ;.1 I < > < 120° > typical • U configuration may be unequal length • maximum flue vent length allowed, 30ft. • L configuration available to fit . 4 12" O 6 r \ r\ ! r) t T [■— 16" — F < 36" )6,1 l<- 12" �{ NOT TO SCALE • CLEARANCES:Kt MODEL TA or TX TA or TX TA or TX TA or TX TA or TX TA or TX 60 100 125 175 205 220 Configuration Top Side Below Top Side Below Top Side Below Top Side Below Top Side Below Top Side Below Straight - Horizontal 2 25 58 2 30 67 4 33 71 6 40 78 6 44 80 6 46 83 Straight - 45° Tilt 4 4 -46 50 4 4 -58 67 6 4 -63 70 8 4 -67 74 8 4 -72 78 8 4 -77 81 U -Tube Horizontal 2 25 59 2 30 71 4 34 74 6 40 78 6 45 82 6 46 88 • Other layout configurations are approved • Lower clearances are allowable at 25' from burner • Side reflectors and lower shields are available • See installation manual for complete information . SUPERIOR RADIANT PRODUCTS LTD. DISTRIBUTOR (' ri 428 Millen Rd., ; t Stoney Creek, ON 18E 3N9 Phone: (905) 664 Matchless Energy Management, Inc. T011 Free: 1-800-521-HEAT (4328) ORf£N SOLUTIONS FOR NfAT/NG AND I IGHTING . SUP :m®R .,, ; , . Faz: (905) 664 -8846 973 - 335 -5885 • i ' 'PRODUCTS ` Website: www.superiorradiant.com . Email: sales @superiorradiant.com All rights reserved. This document or part thereof may not be reproduced or copied in any form or by any means without the written consent of Superior Radiant Products Ltd. The information given is current at the time of printing, but is subject to change without notice. LT097 /R /50 ti � �: ^�, "� ��7 I � ; �? �� S r 'k S +t "� t � ° + h`,Y"s• �a 4 v w r�k� •�'yr"'� a t��� �. S'��n� � �, j v €�k h �. �P'j�^ f Wr c [ � 1 �' , � l � I �O�r • ;, .� 6 .. ,� ��� b v �` r S /TX/ tf "r - S }gg RADIANT;PRODUQS Two Stage Heater ' , Rate 30 -40 45 -60 60 -80 75 -100 95 -125 115 -150 130 -175 160 -205 165 -220 . , (1000 btuh) y r't „ L N t.. Lengths 10' 120' 15' 130' 20' 140' 20' 140' 30' 150' 40' 160' 50' 160' 150' 70' 60' 170 ., • Emitter tube: 1st tube is aluminized heat treated — balance can be aluminized heat treated or hot rolled '; ' ` • Venting: Maximum total vent length: 30 ft. ;` I to . Maximum total fresh air allowed: 30 ft. °', .;' Total vent length plus outside air cannot exceed 50 ft. • Special configurations: 60,000 BTU -15 ft heat exchanger with 6ft stainless steel baffle �� P ` 80,000 BTU-40 ft. heat exchanger with no baffle it k 100,000 BTU-40 ft. or 50 ft. heat exchanger with no baffle f, h, ' 205,000 BTU— 50 ft. heat exchanger with 4 ft. baffle at 40 ft. and an 8 ft. ,',; . baffle at 50 ft. Gas connection: 1/2" N.P.T. ( female ) @ heater r 4 +p Minimum inlet pressure: Natural -5" W.0 Nat. Gas and 11" W.C. LPG !; c • Electrical: Each heater -120 V AC 60 Hz 1 AMP, 36" long power lead � it w P FEATURES t a , 40 TA TX T XR , m^ „ ,'y • Two stage • Two stage • Same as TX Model plus... 0 yl e , , • Hinged door cover (easy to • Burner box completely gas- • Burner box is sealed for out- , , ' service) ket sealed door conditions ` F f I'. Unit can continue running • Unit can continue running • Rubber gaskets are used 4 while servicing while servicing instead of fiber ,10 • Self diagnostic module • Self diagnostic module • Silicone used to seal cor- � r . , ,, • DSI, 3 try ignition ( direct • DSI, 3 try ignition ( direct ners and joints 4 ' spark) spark) • Weather resistant electrical , ` . 5 • Operation light • Operation light components used for exte- r rior connections • Low voltage controls Low voltage controls (no • Deep reflector design is relay required) • Heat exchanger is standard L, + ^ 99% heat treated aluminized ���, 99 /o efficient • Deep reflector design is Ii w ; • Separated components in 99% efficient steel tubing ; ' ∎ ; burner box ( electrical com- • Separated components in • Stainless Steel burner boxes 4:11 ponents are not in air burner box ( electrical com- available as well as tubing :g stream) ponents are not in air and reflectors • Three year warranty on all stream) • Units are wind resistant v r components • Three year warranty on all • Ten year warranty on alu- ( ,�;` • Pre and post purge components minized heat exchanger `.`, • Seven year warranty on hot • Pre and post purge a w r roll heat exchanger • Seven year warranty on hot, • Ten year warranty on alu- rolled heat exchanger Y n minized heat exchanger • Ten year warranty on alu- 4r k! SRI minized heat exchanger ,4 k il id .Y" tt .. , i r )Lt *. , 'SC .. - .. • ;, `1a J r rd ! • ' W4r'S' ,,,,,, .fA •'. , ' V" 44,'''''.4. "..'§ �'' ' 5 ! fi fy V e r i c p , K rk �� { 1 ` " t i ti ' M1r �k� k ,+ Y fl� B �� " • "� 9 a � yf,�. J(�, yr e � k �t � r d, t � � �. � d`D a + �v r A '� r�h?1?+ . e+ � ,. '�`u� .''�'��� - . ,�r.....�"Jre .� r is. �.� � Aa +.rk� -,. '#: ,�`.Y .. '� • 0, s�+ -�5 Rev. 2008 -12 -01 „ „.* Xa � F*i tt mss, 4 . b s® np +. - W StE:` 7n.'. . 1 4 .. 1 o. . Y A r t r F 'd ti. r- .. V ^ '111 € . ,1 1, y, Hr . ' 4 i'. , ,—” { [ -, . ''! • K gam^ 3 §> A:it— Alt- *.t t • { � 6 e rt a. r • • f xl 1 - L. - - _... _ 3r •T RESH y Z t L` LL - . �.._� >� s.w- S - i l l s.--4 : i. , 4 .rrrr + \ % ' L ' v ±..• 1 Composite Photo - Morgantown WV V2 gas cecnnecgion he-7 eM1 3 99 fach h aqe[r tis equipped r.‘55(ch inqenna[i 24ve c©°©0 FiscAa'Rjon cre[Iay connec 18/33 wirre heErce. wen- c r serves as a wh *tin Hance disc Mug runect. °mint 12 cv groan de receptade to structure atiove heater. Starting current - rn 1 I 2 1 3 1 4 T 5 1 6 1 7 I 8 J Reflector D End Cap D Reflector Support \._ Reflector Overlap ,/ Approx. 8" i�� Loose 'N., Vcnt -N -„ Screws v. Adapter pk / Bend Tab Tight Fasten Endcap Screws with Screws C over End / C of Tube Install Baffle \— as required in last section et of tube Lo � , Altip Screws �� Heat• Exchanger Screws Tube Install "J" Bolt rr ' at fast hanger ���, Tube Tube Flange B Coupling Combustio B B 0j Tube ' , r Assemurner bly Tube & Reflector 3" �� Hangers Gasket DIMENSIONS ARE IN INCHES DRAWN BY: UNLESS OTHERWISE SPECIFIED C.POTTER SUPERIOR RADIANT PRODUCTS TOLERANCES ARE AS NOTED REVIEWED BY: UNLESS OTHERWISE SPECIFIEC TITLE A 3DECIMALPLACES +/ - .0? TX OVERVIEW OF INSTALLATION A 3 DECIMAL PLACES +/ -,015 APPROVED ANGLES tl MATERIAL/MAKE FROM: • THIS DRAWING IS CONFIDENTIAL SIZE: DRAWING NUMBER: REV. AND IS THE PROPERTY 00 X FINISH: SUPERIOR RADIANT PRODUCTS. UNAUTHORIZED USE OF THIS SCALE DWG TYPE I LOCATION SHEET: DRAWING IS FORBIDDEN. X I X 1 of 1 CONFIDETIAL: No pan of this document or information contained herein may be reproduced or vansmiaed in any form nr by any means. electronic or mechanical, for any purpose. without the express written permission of Superior Radiant Products Ltd. I I 2 1 3 I 4 .+ . 5 I 6 1 7 1 8 I I 2 I 3 I 4 5 I 6 I 7 I 8 D ''''.."■„,,.....„..,, D 10' Locate Tube and Reflector Hangers (i 10' every 10' thereafter. j 8 1_ 9 1 0 ``• C Coupling Should Be , ` l C Loosely Fitted 61 1 Install "J" Bolt g at first hanger LI to Tube , Flange Combustion ) Tube , ,/ /„ / fr O 0 • B Reflector B Support �3" Tube & Reflector Hangers DIMENSIONS ARE IN INCHES DRAWN BY: UNLESS OTHERWISE SPLCIFI[C C.POTTER SUPERIOR RADIANT PRODUCTS x . TOLERANCFS ARE AS NOTED RLVILWLUHY: Ci) X x < UNLESS OTHERWISE SPECRTEE TITLE: A o 9 Z 3 DEC PLACES ♦/ -.015 APPROVED INSTALLATION OF A 2 DECIMAL PLACES 41-.02 , 1�1 y Xyj ANGLF_S 2I' FLANGED TUBE X MATERIAL/MAKE FROM: 4 x .� ®�WROIa@i�Q7�I. SILL: DRAWING NUMBER: REV. p�� _ X X X FINISH' ilim iss SCALE: DWG LOCATION X X SHEET: xxo I X X Iofl I 1 I CONFIDENTIAL: No pan of this document or information contained herein may he reproduced or "ansmined in any form a or by any means. electronic or mechanical. for any purpose. without the express wruten permission of Superior Radiant Pr ducts I.Id. 1 I 2 I 3 I 4 . 5 I 6 I 7 I 8 I 1 2 1 3 I 4 `cr 5 1 6 1 7 1 R D D POSITION COUPLING IN EITHER THE 10 O'CLOCK OR 2 O'CLOCK POSITION. ENSURE TUBES ARE FULLY INSERTED IN THE COUPLING. TIGHTEN PROGRESSIVELY AND ALTERNATIVELY TO AVOID WRINKLES IN THE LINER. 4111 v; /� 1 . ( It i X 11 B \ B DIMENSIONS ARE IN INCHES DRAWN RY: UNLESS OTHERWISE SPECIPIEL C.POTTER SUPERIOR RADIANT PRODUCTS x 3 TOLERANCES ARE AS NOTED KEN IEN EU HY: C4 x xx UNLESS OTHERWISE SPECIFIEC A O ii X4 3 DECIMAL PLACES .1 -015 APPROVED TITLE: F. COUPLING POSITION A H X �( ANGLES TI° I� X MATERIAL/MAKE FROM: 1--1 x 71311$ WlNI a@im. SI"LE.: C I DRAWING NUMBER: IRE X FINISH: SCALE: UWG TYPE: LOCATION SHEET: xx iiJaW I: I I X X I 1 of 1 I I I CONFIDENTIAL: No pan of this document or information contained herein may be reproduced or transmitted in any tone a ur by any means, electronic or mechanical. for any purpose. without the express written permission of Superior Radimt Products Ltd. I 1 2 1 3 1 4 .tea 5 1 6 1 / 1 8 Configurations Heat Exchanger Length Model High Rate Low Rate (ft.) Baffle (BTU1Hr) (BTL) Minimum Maximum (ft.) TA'TX. TXR-40 40,000 30,000 10' ?0° 6' TA'TXfTXR -60 60.000 45,000 20' 30' 6' TA +TX.'T L -80 80.000 60,000 20' 30' 12' TAATXiT.a -100 100.000 75.000 20' 30' 12' TArIX'Tk - R -125 125,000 95.000 30' 50' 12' TA'TX"TkrR -150 150,000 115,000 40' 60' 6' TArTX/T_YR -175 175.000 130,000 50' 60' - TArTX/ t -205 205,000 160,000 60' 70' - TA.rTX;'T_.R -220 220,000 165,000 60' 70' - Table 1: Configuration Information Note: - Baffles are always placed in the last section of radiant tube. - Baffles are either alurini7ed or stainless steel sections 6' ft. long. - When only 6' ft. is required an aluminized steel baffle is installed, except on the TA/MI where a special 6' ft. stainless steel baffle with a red identification tab must be installed. - When 12' ft. is required the al nmiiiized steel baffle is lengthened forward (toward the burner) with a 6' ft. stainless steel section. Part numbers for reference are: CT016 Baffle for TA/TX'TXR -40 only. 6 ft. long, stainless steel with red identification tab. CT007 Baffle 6' ft. long, aluminized steel CT006 Baffle extension. 6' ft. long stainless steel. Burner ■■ CT006 - 6' SS Baffle CT007 - Aluminized Baffle --- 10' Flanged Combustion Tube 10' Radiant Tube Extension Model TXR10N2A 1 1 2 1 3 1 4 . D 0) D „)'- 6.1 ( / 0 . : 1) C —__-2\ _ IP � Vent Install Baffle Adapter � � as required in Bend Tab \ _ last section over End \ �� \ of tube v of Tube \ L=TTT TTi: \\ DI ARE IN INCHES DRAWN BY: U NLESS OTHERWISE SPECIFIEE C x W SUPERIOR RADIANT PRODUCTS ^ x TOLERANCES ARE AS NOTED RE ''LEA EUB1: r vJ x < UNLESS OTIIERWISE SPECIFIED A z 0 # Z 3 DECIMAL PLACES . /05 APPROVED TITLE: BAFFLE INSTALLATION A 1� ANGLES iI' MATERIAL/MAKE FROM: 1�1 x ma®ormaam, SILE: I DRAWING NUMBER: IREV. X x x xx . FLV ISI {; RT4� SCALE: UWG TYPE: LOCATION SHEET: x x< I X I X I l oft 1 I I CONFIDENTIAL: No pan of this document or intonation contained herein maybe reproduced or transmitted in any fort a or by any means. electronic or mechanical. for any purpose. without the express written permission of Superior Radiant Products tad. 1 1 2 1 3 1 4 L1. 5 1 6 1 7 1 }i 1 1 2 1 3 1 4 } 1 6 1 7 1 8 l p D 6 D _ ri‘, ,4 C' .., _ . . c ,.....„ ,,,,,,, O' 4 ,_ ,,,,,, ,, _ ...._ , 4 B \ � I / B Insert End Cap into Reflector /0/ 1 and Secure it with #8 x 3/8" Screws // . DIMENSIONS ARE IN INCHES DRAWN BY: UNLESS OTHERWISE SPECIFIEC C PO1TER SUPERIOR RADIANT PRODUCTS x ES TOLERANC ARE AS NOTED KE�IEW EU KY: ' < UNLESS OTHERWISE SPECIFIER A Z XX x TITLE: , X % Z DECIMAL PLACES +/ -.01 END CAP INSTALLATION A 1 O x X DECIMAL PLACES 0 15 APPROVED 1N ►�i � X MATERIAL/MAKE x ANGLES ±I° x MATERIAL/MAKE FROM: '�®ANII7Ia� SEE: SE: I DRAWING NUMBER: I REV. X ✓ WW X X F FFINISH: D SCALE: DWG TYPE: LOCATION SHEET: xx< X X 1of1 x x O 1 1 I CONFIDENTIAL: No pan of this document or information contained herein maybe reproduced or transmitted in any fort a or by any means. electronic or mechanical, for any purpose. without the express written permission of Superior Radiant Products Ltd. I 1 2 1 3 1 4 .".. 5 1 6 1 7 1 8 1 I 2 I 3 I 4 V 5 1 6 I 7 I 8 D D ,,,, ,,,,,,..-;:...) \ _ r .....,.....„ .„-....„,,.... ` / h 1 j l nstall End Cap as per irip4 In stallation of End Cap C , Figure C ` (. = h D eco- G rille Cross Strap �:i .. ► ► . Fastened with Screws Notch Deco - Grille Support '= =` for Hangers and Supports : -, 04 - 2,-1 4 Deco - Grille Support � * ' r ' Installed from inside of Shield and held by Screws from outside *eco -Grille End Angle Fastened to Deco - Grille Supports B and Trim edges as required B DIMENSIONS ARE IN INCHES DRAWN BY: UNLESS OTHERWISE SPECIFIEL CPOTTER SUPERIOR RADIANT PRODUCTS x , TOLERANCES ARE AS NOTED REVILE ED BY (J) x x < UNLESS OTHERWISE SPECIFIES TITLE: A Z, x X x Z 2 DECIMAL PLACES +/ -.02 INSTALL OF DECO - GRILLE A O ii 3 DECIMAL PLACES +/-.015 APPROVED 4 X ANGLES 2I° DIRECTLY TO HEATER M ATERIAL/MAKE FROM: ��wtrnnma��t. SI "LE: DRAWING NUMBER: REV. X x �,�ra>a»u><aP C I FINISII: sea SCALE: DWG TYPE: LOCATION SHEET: XX< 1:1 X X lof xxo CONFIDENTIAL: No pan of this document or information contained herein may be reproduced or transmuted in any form a or by any means. electronic or mechanical. for any purpose. without the express written permission of Superior Radiant Pnducts Ltd. 1 1 2 I 3 I 4 Ails 5 1 6 I 7 I 8 F -------- :-.:-...-- _ , - oil . . • az ' 1 '\f_ .1 , .._ _ ., , 3:1,- 1 \ c p mi n i 181 -,---------\,, \C \ ., \ ... \ s 1 .21 olmeerig - - , r , ' - , 1 -9 , = ,: ..., la 10 al VIM t ■, • 11 0 'I ., , ' \ .., ,-, ,i' / \ r4/1 / , ••• , a f? i‘ r ,,. - • , ,,,, r„, ", - dr 01111111 ---I 'Anelleilaill ' ' :, , -,, ,,,..... „....-..- .- , •• - , 4 . ' s ''''' ,, ,.. 1 1.,• ::;'.'-0:74',:.:_'1::._:::; ":sl.gagrn-_':r3ail-:a'"I'---:sbvl'2:"31','c,,..:°:_rc,_--:';';t:':':,-::€''''I4f1:):'n' ;L . II 01:\,, „,,,,,,17., 7_e:',7-_,_,_'illt'''f,_'./..\.01"1,1_,..i,,,..,.',.''''.,:.,..7.a.r:''L--,,,i,c...,:,..,:...kili.t.,1,121%.,17.t44.,...,76-.:1_,....,03,:,.}E\,-'.',.'l'i,y,..'...z..,...„,t,...,,..,101ili,".1)(-it,t,-,..,tP,41,,,,,,I.,..":f....1.,,-.‘,.t,„',:',,_::„...,vtr,":::1,..1..-tirt.:_,‘,..,,T,'-•:„...,.;;.-.1;41.A..1,4%,,i...,11"r'orp,(,,..ii.,,va--,:e_1,...-41.,,,,,,,,-,-,Q..\,-.,.t.i.,,."'.,..'..Q.'..kii...".,..;.1,..,,......:.011..,a.::''1„,',.,i.1‘,,‘,',I'll . ; f •-.... -, . ..... al). ..,, 4 a 2:4 i V ill I 1 1 .. ■ ---. , .... i 4 - , . _:-___, r•-. . i 4 • ' 1 i • _. „.- =. ,eil c-= . , 1 ‘ °,.. •• '''' ‘...__. / 1 ..*.. 1 , A s , . =JIM MV,,,, „,,••,, ,,„ . , , , f ' --, „ • - /. ■ A f*. ' ' ..,=2 1° I i V , "r \ i f % I 1 ■•11 - - .. - , ._.,...... •11:1..„S,. I... s ' 14 %; 1;1 1 ' ',. it f.- •• "”" ' - .11 1 i INF I 1 / i ri / , .40, r ' , \ ..„,..; ,, „•--.....0 - --I 4 / r-- - j Ma.. "' ". ' '. ' ,,,..,./..'- i l' 6 . "/ - ' '..-• ' t t` :,. •..- -- 4 ' ', 1 ,),-. • R i _ . 6: .4 " '''. (I 1 i 7. . 1........-. .„...,,,......- . .• .,-..-.. .0, k ‘ t , .- . ' t , , A -. ...AAA 41 ) ' • iL I): $ l + Z;Va; et .4. Li ' , 4,... = _,.,- ; .._,L - 1_.22-th.6..10.114 6_....7. . - ‘ _ II .1. : - . - ;41.* k . " ■ II g, . 4 f? aiiki.....___ . 1 = , y, . 4 • P 1 rs" :Is. ' A # - 4 • , ,1/4 1 l' , z , ) ' V im 7. tlfi - ...- :---.. - - t „--„,.„` , AA , i , Mr-, 1 At ... , ''''' f • 1 ' C ' ....,.. ■ t f ' 1 Jj4,4 I c, ====:::ii 4 4 , _ •V "'" •• i3. V II - • Pc ' P 4 I 5 •V // ' • i. '1 ---'="::- /.. , ...,,_ . , c • - I , 5 .• _ , '' _> \..............., 5. b .,,, . 1. t'l it. sc ,- I I .. • -, ii. •••••• „................,,,,a,,,,,,,,,,,,,Z,S,..•■■■••••■•■••••■•• ^ - a ' ' j 13 I pi —_____ . .....„... __..........._____ . , - ---...._ - u_iii- op •r7..e;:0==.6 • 1 1 de'ing o4-...,„„" , ,... 4. ',T.''' - -,...;:. - 'M.. - lir • . i , / --- -- I \■,,, .. 4 • KR'. • _ ' • _,-; . ••/ t e• • • , , ' . - . • . • „... ,. ,, --,* ,- • ....• ,v ! Ai . . , •,,-. ,, ., . . ., • • r,.. ' aTi..r = ., . ...\.! , ,...... .,,, ..,..41,.. , ,... ,..,. .. ca , , t 0 , , - • i I 1 im;= a i r , .,,,, c e - 0 ii ,. _ , , 1 , , ..., .., a e, . k - ,- , • I. • . - Ch to 1' . ,. . - V p • Ch. I ,,-. , _ . _ 1 1 2 1 3 1 4 `441:0- 5 1 6 1 7 1 8 • D Shut -Off Valve must be parallel to burner gas inlet D Shut -Off Valve - .�. 45° 45° - ... liNall 1 90° 1 // C 12" i i B B 1/2" Stainless Steel Flex Gas Connector DIMENSIONS ARE IN INCHES DRAWN BY: UNLESS OTHERWISESPECIFIE•C C.POTTER SUPERIOR RADIANT PRODUCTS X M TOLERANCES AREAS NOTED REVIbWtUBY: x < UNLESS OTHERWISE SPECIFIEC A O X XX XZ 3 DECIMAL PLACES +/ -015 APPROVED 'TITLE. GAS SUPPLY DETAIL A 4 X X ANGLES II° M ATERIALIMAK EPROM: H X •� ®�ppm ate, SIZE: I DRAWING NUMBER: [REV. X X X FINISH: SCALE: DWG T LOCATION SHEET: xaxco [ X I X [ 1 of 1 I I I CONFIDENTIAL: No pan of this document or information contained herein may be reproduced or transmitted in any form a or by any means. electronic or mechanical. for any purpose, without the express written permission of Superior Radiant Products lid. 1 1 2 1 3 1 4 .t"+. 5 1 6 1 7 1 8 HIGH OFF " 0 ; ROTARY TIMER OPTION Timer Controls 24V Power DPDT Switch Controls Hi /Lo /Off Rate (see schematic wiring diagram) SUPERIOR RADIANT PRODUCTS SERIES TXR•TWO STAGE GAS RADIANT HEATER OPERATION SEQUENCE OF OP I,I . On high output mode, each heater consumes approximately one Therm of Natural Gas. Total fuel cost for operating two heaters in high mode is approximately $3.00 per hour.' . Set HighlLowlOff control switch to desired heating level. Rotate timer to desired on time. a • Combustion air blower will start — air proving switch makes, energizing control module. . After 45 second pre - purge, igniter and gas valve are energized for 15 second ignition trial. • If flame is established and sensing rod "reads" a rectified flame signal, the gas valve remains I the 24v control circuit power is interrupted. Heater open. At the end of the timed cycle, t e gas p p 9 valves will shut; the blowers will continue to run for a post purge period, and then shut down. t off position or moving • Manual shut down by rotating timer to p by g switch rocker to neutral. • See heater operating manual for additional information about control module function. , GROUNDED GROUNDED �.. RECEPTACLES RECEPTACLE 1 � BURNER BURNER Box Mounted Transformer Connect To 120V Supply 24v I ' I , , I I I I J High Low I f U ® t 0 I ) ROTARY DPDT SWITCH TIMER WITH JUMPERS 120/1/60 15 Amp From Breaker ALL ITEMS MUST BE PROPERLY GROUNDED HEATERS TO BE FURNISHED WITH FACTORY INSTALLED ISOLATION RELAY I ! Field Control Wiring Schematic Individual Heater control No Scale Please do not hesitate to contact us should any question arise: Matchless Energy Management, Inc. 973- 335 -5885 j., ranainatchless- merry. cnnl I cell John Grant - 973 - 876 -6356 ' Charlie Grant - 973 - 617 -7312 Bob Grant - 908-698-1823 SUPERIOR RADIANT PRODUCTS ' 905- 664 -8274 Pat Caruso i �,,a i �1 1 � X 7 3 �� `� .`�+�� Zt } _ , ' ^T1 � 4 • �,, . <,,;--,-, / ' { " � (r'� r7 , ". 3 „.. , . iqf �l0 r°� J' w * i t( rN ,�. ;\,!_ � 5, 1 f) 'r _ � I r Y �. +y' ����f� . MVO r r ' 5 0' 14 41 -J, it ♦ d . � � 1 . _ � '- i '�. �d .A. i :.a 1 , �� f " ii) I _ T w EL.I fie. j( �a 1 r +l -y • Y -'1 -} 1 !_.__ �!_ fir". f. - F va . - S C I' „mss � w � _ _ ��... �, i. y , , �.X . t�� A� , [ i - ...‘lw 4 - I 1 ,,,, ‘,.-\.___—_ , - = IL Hi Efficiency Gas Radiant Heat For Every Application