Loading...
Specifications (2) • Model number nomenclature co I*; 48TM004 -014 3 to 12 To - ASHRAE 90.1 Compliant r- et n Example: 48 TM D ' 006 P M F 6 - 1 HA • . 48 - Packaged Rooftop .T Electric Cooling/ F1OPt Z Natural Gas Heat Packaging TM- Constant Volume, Standard Efficiency 1 - Domestic 3 - Export Heat Options: California Compliant Design Changes 49 States L - Low NOx Low Heat D - Low Heat M - Low NOx Medium Heat E - Medium Hea: N - Low NOx High Heat Voltage F - High Heat 1 - 575-3-60 3 - 208/230 -1-60 Tons Nominal Capacity 5 - 208/230-3-60 004 - 3 Tons 6 - 460 -3 60 005 - 4 Tons 006 - 5 Tons 007 - 6 Tons Coil Protection Options (fin/tube) 008 - 7 -1/2 Tons - - Ai /Cu Cond & Evap 009 - 8 -1/2 Tons 6 - Cu /Cu Cond & Evap 012 - 10 Tons C - Cu /Cu Cond & Al/Cu Evap 014 - 12 -1/2 Tons F - E-Coat AI /Cu Cond & Al /Cu Evap G - E -Coat Cu /Cu Cond & AI /Cu Evap V - AVCu Pre -Coat Cond Fin & AI /Cu Evap Controls and Sensors - - None K - Novar ETM2024 Control' Indoor Motor Options N - Novar ETM3051 Control' - - Standard Motor & Drive P - PremierLinkr"' DDC Control A - Alternate Motor Z - Apollo Control M - High Static Indoor Motor LEGEND 'Contact factory for availability and application information. Al - Aluminum tRefer to 48TM Price Pages or contact your local Carrier representative for Cu - Copper FIOP code table. FIOP - Factory- Installed Option • ARI* capacity ratings UNIT NOMINAL NET COOLING TOTAL SOUND RATING 48TM TONS CAPACITY (Btuh) kW SEERt EER" (Bets) IPLVtt 004 3 35,000 ._ • `I -P. 005 4 4.0 10.0 8.7 8.1 N/A 47,000 5.3 10.0 8.8 8.1 N/A 1 , y ' 007 • 5 57,000 6.7 10.0 8.5 8.1 N/A 71,000 7.0 - 10.1 8.0 N/A 008 7i/ 88,000 8.7 - 10.1 8.2 10.5 009 8 100,000 9.9 - 10.1 8.2 10.4 012 10 114,000 11.3 - 10.1 8.4 11.0 014 _ 12 136,000 14.3 - 9.5 ' „ 8.6 9.7 LEGEND 2. ARI ratings are net values, reflecting the effects of circulating fan heat. Bets - Sound Levels (1 bet = 10 decibels) 3. Ratings are based on: db - Dry Bulb EER - Energy Efficiency Ratio IPLV - Integrated Part -Load Values SEER - Seasonal Energy Efficiency Ratio a tr ' A. ' r tigA wb - Wet Bulb � , 7. ) 4 p : 'Air Conditioning and Refrigeration Institute. ° "` tThe SEER values shown for sizes 004, 005, and 006 are for units with the optional belt drive motors; SEER rating for these units with the standard direct Cooling Standard: 80 F db, 67 F wb indoor entering -air temperature and drive motor is 9.7. 95 F db air entering outdoor unit. "ARI does not require EER ratings for units with capacity below 65,000 Btuh. IPLV Standard: 80 F db, 67 F wb indoor entering -air temperature and 80 F For these units, the EER rating at ARI standard conditions is provided for infor db outdoor entering - air temperature. mation only. 4. All 48TM004 units are in compliance with ASHRAE 90.1 2001 Energy t tThe IPLV applies only to two cooling units. Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website: http:/ /solstice.crest.org/efticiency/ NOTES: bcap to determine it compliance with this standard pertains to a given geo- 1. Rated in accordance with ARI Standards 210/240, latest revision for sizes ( graphical area of the United States. 004 -012) or 360. latest revision (for size 014) and 270, latest revision. California, Maryland, Washington, Wyoming and various local and state building codes adopted the ASHRAE 90.1 efficiency standard on October 29, 2001. 50 • Performance data - - _ - vC'llaxl !C'J- COOLING CAPACITIES 4871%1004 (3 TONS) LEGEND •' Temp (F) Temp (F) Air Entering Evaporator - • Cf 1500/0.17 Edb - Dry Bulb Air Entering 900/0.11 1200/0.14 • . Condenser . - Tem k - Ente sor Moto - . ,(Edb) „ _, P (� Air Ente �9 Evaporator - kW - Compressor Motor Power Input . 72 -, 67 62 ._ 1.72 67* 62 ' 72 67 62 • Ldb . Leaving Dry -Bulb TC .. • . 42.8 38.9 35.0. 44.8 40.8 37.0 45. 41.8. 382 Lwb .- Lea Wet -Bulb !a 75 SHC 20.0 24.5 28.7 21.8 27.5 32.8 23.0 0.0 36.0 SHC -' Sensible Neat (10 city (1000 Btuh) Gross ,pa kW 2.91 2.81 " 2.70 . 2.99 2.88 2.78 3.02 2.92 2.82 TC - Total Capacity (1000 etu) Gross • TC 40.8 36.9 33.3 42.5 38.7 35.0 43.6 39.9 36.1 NOTES: 85 SHC 19.4 23.7 27.9 21.0 26.8 31.8 22.6 29.7 35.1 1. Direct interpolation is permissible. Do not extrapolate. kW TC 38.7 3.14 3.01 2.90 3.20 3.08 2.97 3.24 3.14 3.02 2. The following formulas may be used: 95 SHC 8.8 22.9 27.0 0 3 26.0 30.9 22.0 28.8 34.0 tub = _ sensible capacity (Btuh) kW .3.35 3.21 3.09 3.42 3.29 3.16 3.47 3.35 3.22 • 1.10 x cfm TC 36.5 32.8 29.2 38.1 34.3 30.9 39.0 35.2 32.4 t,„,, = Wet -bulb temperature corresponding to enthalpy of air leaving 105 SHC 17.8 22.1 25.9 19.6 25.2 29.8 21.2 28.0 32.3 evaporator coil (h - fi kW 3.55 3.41 3.27 3.63 3.49 3.35 3.68 3.54 3.43 TC 34.3 30.7 26.9 35.7 32.1 28.8 36.5 32.9 30.6 , = ho„b total capacity (Btuh) 115 SHC 17.0 21.3 24.8 19.0 24.4 28.8 20.5 27.1 30.6 4.5 x cfm kW 3.76 3.60 3.45 3.84 3.68 3.54 3.86 3.74 3.64 Where: h = Enthalpy of air entering evaporator coil. 3. The SHC is based on 80 F edb temperature of air entering evaporator coil. 48TM005 (4 TONS) Below 80 F edb, subtract (corr factor x cfm) from SHC. Temp (F) Temp (F) Alt Entering Evaporator - Cfm/BF Above BO F edb, add (corr /actor x cfm) to SHC. Air Entering 1200/0.12 [ 1600/0.15 I 2000/0.18 Condenser r Temp (F) Air Entering Evaporator - Ewb BYPASS ENTERING AIR DRY -BULB TEMP (F) 72 67 62 72 67 62 72 67 62 FACTOR 79 78 77 76 75 under 75 TC 57.9 53.1 48.3 60.4 55.9 51.3 62.2 57.3 52.9 (BF) 8 82 83 84 85 over 85 75 SHC 27.2 33.3 39.2 9 37.2 44.8 31.4 40.3 49.1 Correction Factor kW 4.07 3.93 3.79 4 4.03 3.90 4.24 4.08 3.96 TC 55.7 50.8 45.3 57.7 53.4 59.4 55.0 50.2 .05 .10 .98 1.96 1.04 2.96 2. 6 2. 3.12 4.18 85 SHC 26.4 32.5 37.8 28.4 36 "7 30.5 40.3 47.9 . 2 3.49 4.36 h oe formula kW 4.40 4.24 4.08 4.47 4.35 0 4.54 4.42 4.25 .320 .87 1.54 2.29 3.05 4.36 shown below. .30 .76 i 1.53 2.29 3.05 3.82 - 7 TC 52.9 48.1 42.5 55.2 50.5 NS 56.7 52.0 47.4 . -1 -•e. 95 SHC 25.5 31.5 36.4 27.6 35.6 42.2 29.7 39.2 46.7 Interpolation is permissible. kW 4.70 4.54 4.36 4.78 4.63 4.47 4.87 4.70 4.56 Correction Factor = 1.10 x (1 - BF) x (edb - 80) TC 50.1 45.3 39.8 52.3 47.6 42.8 53.6 48.9 44.9 105 SHC 24.4 30.3 35.1 26.7 34.5 40.7 28.8 38.1 44.6 kW 5.00 4.81 4.62 5.10 4.91 4.73 5.17 4.99 4.84 TC 47.3 42.6 37.2 49.3 44.6 40.0 50.5 45.9 42.4 115 SHC 23.4 29.2 33.7 25.9 33.3 39.3 27.8 37.1 42.4 kW 5.30 5.07 4.88 5.42 5.19 4.99 • 5.48 5.28 , 5.12 48TM006 (5 TONS) Temp (F) Temp (F) Air Entering Evaporator - Cfm/BF Air Entering 1500/0.07 i 2000/0.09 I 2500/0.12 Condenser Temp (F) Air Entering Evaporator - Ewb (Edb) 72 67 62 72 67 62 72 67 62 ' TC 71.0 63.8 55.4 74.5 67.2 59.2 76.5 69.7 62.1 75 SHC 33.9 41.5 47.9 37.4 47.4 55.8 40.6 52.8 61.8 kW 5.04 4.82 4.62 5.20 4.97 4.76 5.29 5.06 4.87 TC 69.2 61.0 54.2 72.9 65.6 57.2 75.2 68.1 61.5 85 SHC 33.4 40.5 47.3 37.0 46.9 54.9 40.1 52.3 61.3 kW 5.50 5.27 5.02 5.66 5.41 5.18 5.75 5.50 5.29 ' % -1 TC 65.5 56.6 50.4 69.4 60.9 71.2 63.3 57.8 .-.ED. 95 SHC 32.1 38.8 45.6 35.8 45.3 52.6 39.1 50.9 57.8 -5 kW 5.88 5.62 5.37 6.01 5.76 5.53 6.12 5.87 5.67 TC 61.9 53.1 47.1 65.4 56.6 50.5 67.1 58.8 54.5 105 SHC 30.8 37.5 44.1 34.5 43.7 50.2 37.9 49.3 54.5 kW 6.25 5.99 5.72 6.38 6.13 5.91 6.50 6.23 6.08 TC 58.2 49.7 43.7 61.4 52.3 47.8 63.0 54.3 51.2 115 SHC 29.5 36.1 42.5 33.2 42.1 47.8 36.7 47.6 51.2 kW 6.63 6.35 6.08 6.75 6.49 6.29 6.88 6.59 6.46 48TM007 (6 TONS) Temp (F) Ter (F) Air Entering Evaporator - Cfm/BF Air Entering 1800/0.06 1 2100/0.07 1 2400/0.09 1 3000/0.11 Condenser Temp (F) Air Entering Eva rator - Ewb (Edb) 72 67 62 72 67 62 72 67 62 72 67 62 TC 81.3 77.8 71.3 82.7 78.7 72.9 84.2 79.7 74.6 85.3 82.5 76.7 75 SHC 38.2 51.3 61.6 40.2 54.2 65.9 42.3 57.1 70.2 43.7 64.0 76.4 kW 4.69 4.63 4.52 4.73 4.65 4.56 4.77 4.67 4.60 4.80 4.75 4.63 TC 78.8 75.6 69.0 81.1 77.1 70.7 83.3 78.6 72.3 85.0 80.5 75.0 85 SHC 37.7 50.4 60.5 40.0 53.9 64.9 42.2 57.5 69.2 44.3 63.6 74.9 kW 5.21 5.16 5.05 5.27 5.20 5.09 5.34 5.24 5.13 5.39 5.29 5.17 TC 77.1 73.3 66.9 79.2 74.8 68.5 81.3 76.2 70.1 82.0 78.0 73.3 95 SHC 37.0 49.9 59.7 39.4 53.3 64.0 4 56.8 68.3 43.5 63.4 73.2 kW 5.80 5.78 5.65 5.87 5.81 5.70 5.94 5.85 5.74 5.95 5.88 5.8 • TC 75.4 70.7 62.9 76.6 72.1 64.8 77.9 73.4 66.7 79.7 74.9 70.9 105 SHC 36.7 48.7 58.2 38.6 52.3 62.2 40.6 55.9 68.3 43.0 62.4 70.9 kW 6.49 6.45 6.26 6.53 6.48 6.32 6.56 6 6.38 6.61 6.53 6.46 TC 72.1 67.9 59.0 73.6 69.0 ' 61.1 75.2 70.1 63.3 76.7 71.9 68.1 115 SHC 35.3 47.5 57.2 37.6 51.2 60.2 39.9 54.8 63.3 42.2 61.5 68.1 kW 7.20 7.17 6.94 7.25 7.18 7.01 7.29 7.20 7.08 7.35 7.26 7.15 • CCCLI { 1C ; 48TM016 -028 Example: 48 TM D 025 G – F 6 – – YA • 48 - Packaged Rooftop Factory- Installed Options' Electric Cooling/ Natural Gas Heat Voltage 1 - 575 -3 -60 5 - 208/230 -3 -60 TM- Constant Volume, Standard Efficiency 6 - 460 -3 -60 Heat Options D - Low Heat Coil Protection Options (fin/tube) F - High Heat - - Al /Cu Condenser and Evaporator M - Low Heat, Stainless Steel Heat Exchanger 8 - Cu/Cu Condenser and Evaporator N - High Heat, Stainless Steel Heat Exchanger C - Cu/Cu Condenser and AI /Cu Evaporator F - E- Coated AI /Cu Condenser Nominal Capacity - Tons G - E- Coated Cu /Cu Condenser 016 - 15Tons V - Back Pre - Coated Condenser Fins 020 - 18 Tons 025 - 20Tons 028 - 25 Tons Fan Drive Position (Standard Motor) - - Standard Motor and Drive Control /Service Options - - Standard Controls G - Service Option with 6 Hinged Access Panels, Non -Fused Disconnect, and Non - Powered 115 -V GFI Convenience Outlet J - HingedAccess Panels S - HingedAccess Panels with Apollo Control Y - Service Option with Apollo Control Z - Apollo Control Option LEGEND Quality Assurance Al — Aluminum Cu — Copper Certified to ISO 9001:2000 FIOP — Factory- Installed Option 'Refer to 48TM Price Pages or contact your local Carrier representative for FIOP code table. 7 r ARI* CAPACITY RATINGS — 48TM016 -028 UNIT SIZE NOMINAL NET COOLING TOTAL • SOUND 48TMD TONS CAPACITY (Btuh) WATTS EER RATING IPLV (decibels) 016 15 176,000 17,064 9.5 88 9.5 020 18 202,000 21,166 9.7 88 10.2 025 20 236,000 24,832 9.5 94 10.1 64P'3 -.0 028 25 278,000 28,535 9.7 94 10.4 UNIT SIZE NOMINAL NET COOLING TOTAL SOUND 48TMF TONS CAPACITY (Btuh) WATTS EER RATING IPLV (decibels) 016 15 176,000 17,179 9.5 88 9.5 020 18 202,000 21,301 9.7 88 10.1 025 20 236,000 24,832 9.5 94 10.0 028 25 277,000 29,067 9.5 94 j 10.0 LEGEND db — Dry Bulb 0 ,. :%, EER — Energy Efficiency Ratio . "'' "s. N2 tPLV — integrated Pal-Load Values . i s wb — Wet B;ilb r , H • 'Air Conditioning and Refrigeration institute. 's'a,,, NOTES: 1 accordance with Stancart 360 -93 and / 0 -95 4 I ?8 - M101 '28 units are in compliance ;iitl, ASH RAC r 1 , 1 Rated in AR � �' " 6 8J. 2L� 2. ARI ratings are net values, reflecting the effects of circulating fan Energy Standard for minimum EER reequirernents. Refer to heat. state and local codes or visit the following website: 3. Ratings are based on: httpi /solstice.crest.orq /efficiency /bcap to determine if compliance Cooling Standard: 80 F db, 67 F wb indoor entering -air tempera- with this standard pertains to a given geographical area of the ture and 95 F db air entering outdoor unit. United States. IPLV Standard: 80 F db, 67 F wb indoor entering -air temperature and 80 F db outdoor entering -air temperature. HEATING CAPACITIES AND EFFICIENCIES — 48TM016 -028 UNIT HEATING INPUT OUTPUT CAPACITY TEMPERATURE STEADY -STATE MINIMUM 48TM (Btuh) (Btuh) RISE (F) EFFICIENCY (%) HEATING CFM Stage 2/Stage 1' D,M016 275,000/206,000 223,000 15 -45 81.0 3750 F,N016 360,000/270,000 292,000 20 -50 81.0 3830 D,MO20 275,000/206,000 223,000 15 -45 81.0 4580 F,NO20 360,000/270,000 292,000 20 -50 81.0 5400 D,MO25 275,000/206,000 223,000 15 -45 81.0 4580 F,NO25 360,000/270,000 292,000 20 -50 81.0 5400 D,MO28 275,000/206,000 . 223,000 15 -45 81.0 4580 F,NO28 360,000/270,000 292,000 20-50 81.0 5400 'All units are 2 -stage heat. NOTE: Minimum allowable temperature of mixed -air entering the heat exchanger during first -stage heating is 45 F. There is no minimum mixed -air temperature limitation during second -stage heating. For entering -air temperatures below 45 F both stages of heat must be energized together to minimize condensation issues and ensure proper unit operation. • 1 2 Performance data .4 T (cunt) - , ,rte s , . • COOLING CAPACITIES - STANDARD UNITS (cont) • 48714016 (15 TONS) LEGEND Temp (F) Air Entering Evaporator - CtMBF Edb - Entering Dry-Bulb . Alt Entering 4500/0.02 5,250/0.03 I 8,000/0.04 I 6,750/0.04 I 7,500/0.05 Ewb - Entering Wet -Bulb Condenser Alr Entering Evaporator - Ewb (F) kW - Compressor Motor Power Input (Edb) 82 67- 72 62 67 72 62 67 72 62 67 72 62 67 72 Wb - Leaving Dry-Bulb lwb - Leaving Wet -Bunt TC 180 195 212 185 200'216 203 218 193'205 219 197 207 222 SHC - Sensible Heat Capacity (1000 BWh) Gross 75 SHC 147 123 99 159 132 104 172 142 112 180 152 120 185 162 125 TC - Total Capacity (1000 Bhh) Gross kW 11.2 11.6 12.0 11.3 11.7 12.1 11.4 11.8 12.1 11.6 11.9 12.2 11.7 11.9 12.2 TC 174 189 204 179 193 208 183 197 211 187 199 212 191 201 213 NOTES: 85 SHC 144 121 96 156 130 102 167 138 106 175 148 114 179 156 119 1. Direct Interpolation is perrriissble. Do not extrapolate. kW 12.3 12.7 13.1 12.5 , 12.8 13.2 12.6 12.9 13.3 12.7 13.0 13.3 12.8 13.1 13.4 2. The following formulas may be used: TC 167 182 196 172 186 200 175 189 202 180 191 204 184 193 205 sensible capacity (BWh) 95 SHC 141 118 93 153 126 98 163 135 102 169 144 108 173 152 112 t/4 ` tads - 1.10 x dm kW 13.5 13.9 14.3 13.6 14.0 14.4 13.8 14.1 14.5 13.9 14.2 14.6 14.0 14.3 14.8 TC 160 173 187 184 177 180 168 180 192 172 181 193 177 183 194 5,n = Wet -bum temperature correspondng to enthalpy of air leaving evaporator coil 105 SHC 138 114 BO 149 123 94 157 132 98 162 140 102 165 147 106 N.o) kW 14.8 15.2 15.6 14.9 15.3 15.7 15.1 15.4 15.7 15,2 15.5 15.8 15.3 15.5 15.8 total capacity (BWh) TC 152 165 170 156 168 179 161 170 180 165 172 182 108 173 182 1'0e = h..o - 115 SHC 134 111 86 144 119 90 150 128 94 154 135 98 158 142 100 4.5 xcf kW 16.1 16.5 16.9 16.2 16.6 17.0 16.4 16.7 17.0 16.6 16.8 17.1 16.7 16.9 17.1 Where: h = Enthalpy of air entering evaporator coil. TC 149 162 ' 174 1 153 165 176 158 187 - 162 166 - 166 170 - 3. The SHC is based on 80 F edb v temperature of air entering rator coil. 118 514C 133 1 10 6F - _ /8 d 148 127 - , 1f e 1::3 - 155 140 -- Below 60 F edb. 53binot (toss fa clo s;Aril boor SRC.. eva P kW 16.5 16;. . 17 167 7.5 1 4 ^ 1: 17.0 1 2 17 1 17 qr...;'.8 _S3 = edb add i .irr:3Ciu - >> : a' OP') 7 . °G. 120 SHC 13..` 1/0/ = 141 - _ 147 -- ENTERING AIR DRY-BULB TEMP•F) BYPASS 79 78 t FACTOR 77 76 75 under 75 co. 4871,1920 18 TORSI ' ( (gF) v 81 22 63 ( 84 85 evsr BS' _ Temp (F} Air Entering Evaporator -- Cfm /BF Correction Factor kilt Alr Entering 5,400/0.095 I 6,000/0.105 I 7,000/0.120 I 8,000/0.140 I 9,000/0.150 .05 1.04 2.07 3.11 4.14 5.1881 an'' Condenser Entering -•- (Edb) 62 67 72 62 6 ,017 Evaporator 6 2 62 SF) 67 r 62 67 72 .20 .87 1Ji 2.62 349 4 38 shown below. .30 .76 1.53 2.29 3.05 3.82 TC 227 247 259 232 251 274 237 255 277 241 258 280 248 261 283 75 SHC 200 167 134 215 178 141 231 194 152 241 205 160 248 219 167 Interpolation is permissible. kW 15.9 16.5 17.2 16.1 16.7 173 16.3 16.8 17.5 16.5 16.9 17.6 16.7 17.0 17.7 Correction Factor = 1.10 x (1 - BF) x (edb - 80). TC 219 238 259 224 242 265 229 247 269 235 250 272 241 252 273 85 SHC 197 164 131 210 175 137 225 188 145 234 200 153 240 214 163 kW 17.2 17.8 18.5 17.4 17.9 186 17.6 18.1 18.6 17.8 18.3 19.0 18.0 18.3 19.0 TC 210 229 248 214 233 253 219 237 258 225 239 261 231 242 263 95 SHC 192 160 126 205 171 133 218 183 141 225 194 148 231 206 156 kW 18.5 19.2 19 -9 18.7 19.3 20.0 19.0 19.5 20.2 19.2 19.6 20.3 19.4 19.7 20.4 TC 200 218 237 205 222 241 210 225 245 216 228 249 221 230 250 • 105 SHC 186 155 123 199 166 129 210 178 138 216 190 143 221 201 150 kW 19.9 20.5 21.2 20.1 20.7 21.3 20.4 20.8 21.5 20.6 21.0 21.7 20.8 21.0 21.8 TC 190 207 225 195 210 228 201 213 232 206 216 235 211 217 236 115 SHC 181 151 116 193 101 124 201 173 132 208 185 139 211 198 146 kW 21.3 21.9 22.6 21.5 22.1 22.8 21.8 22.2 22.9 22.0 22.4 23.1 22.2 22.4 23.1 TC 185 200 - 169 205 - 196 207 - 201 - 205 - - 120 SHC 179 148 - 189 159 - 196 171 - 201 - 205 - - k W _ 22.1 22.6 . - -- 22.3 - - . 22.5 22.9 , - 22.7 - 229 - - 48•MO25 (20 TONS) Tem - Alr Entering Evaporator - Ctm /BF Air Enter rig 6.000/0.04 I 7.0004.05 I 8.000/0.06 I 9.000/0.07 [ 16.000/0.08 Condenser • Air Entering Evaporator - Ewb ! F) (Edb) 62 67 72 62 67 72 62 67 72 62 67 72 62 67 72 TC 237 258 262 242 264 288 2.87 268 291 252 271 295 256 274 298 75 SHC 204 171 138 221 184 146 237 199 156 247 210 16.1 257 221 172 kW 16.7 17.4 18,1 16.9 17.6 133 17.1 17.8 18.5 173 17.9 18.6 17.5 18.0 18.7 TC 229 2.49 272 234 254 278 239 260 283 245 262 286 250 265 287 85 SHC 201 167 135 216 180 142 231 193 150 240 203 157 250 217 167 kW 18.1 18.7 195 18.3 18.9 19.7 18.5 19.1 19.9 18.7 19.3 20.1 18.8 19.4 20.1 TC 220 239 261 225 245 267 230 249 271 235 251 275 241 255 277 95 SHC 195 163 130 211 176 138 224 188 145 233 199 152 241 210 160 kW 19.4 20.2 20.9 19.7 20.4 212 19.9 20.6 21.3 20.1 20.6 21.4 20.3 20.8 216 TC 209 228 249 216 234 254 220 237 259 225 240 262 230 242 263 105 SHC 189 159 126 206 171 134 217 183 140 225 195 148 230 205 154 kW 20.9 21.5 22.3 21.2 21.8 22.5 21.4 22.0 22.7 21.6 22.1 22.9 21.8 22.2 23.0 TC 200 217 237 205 222 241 211 225 244 216 227 248 221 229 249 115 SHC 185 154 122 199 166 129 209 178 136 216 189 143 221 200 150 kW 22.5 23.1 23.8 22.7 23.3 24.0 22.9 23.4 24.2 23.2 23.6 24.4 23.4 23.7 24.4 TC 194 211 230 199 216 - 205 218 - 210 - - 214 - - 120 SHC 183 152 121 195 164 - 204 175 - 210 - - 214 - - k W 23.2 23.8 24.6 23.5 24.0 - , 23.7 24.2 - ,23.9 - - 24.1 - - 48111028 (25 TONS) Temp (F) Air Entering Evaporator - Ctm/BF Air Entering 7,000/0.05 I 8,000/0.06 I 9,00070.07 I 10,000/0.08 1 11.250/0.09 Condenser Air Entering Evaporator - Ewb (F) (Edb) 57 62 67 72 57 62 67 72 57 62 67 72 57 62 67 72 57 62 67 72 1 TC ' 256 271 299 ' 327 ' 267 278 ' 305 ' 338 ' 276 r 283 ' 309 341 ' 285 288 1 313 344 ' 294 294 318 347 75 SHC 256 232 196 159 267 249 208 166 276 265 220 173 285 281 232 182 294 294 252 198 kW 18.0 18.3 18.9 19.6 18.3 18.5 19.1 19.8 18.5 '18.7 19.2 19.9 18.7 18.8 19.4 20.1 19.0 19.0 19.5 20.2 TC 248 262 208 316 259 267 293 322 267 273 298 328 276 276 302 331 284 285 305 336 85 SHC 248 228 192 154 259 244 204 161 267 259 216 169 276 274 228 175 284 284 244 187 kW 20.0 20.4 20.9 21.5 20.3 20.4 21 21.7 20.6 20.6 21.2 21.9 20.8 20.8 21.3 22 21 21 21.5 22.1 7 TC 241 252 277 303 251 257 281 309 2.59 26 286 314 266 267 290 317 274 275 293 321 .✓�. . 85 SHC 241 223 187 149 251 239 198 157 259 210 164 266 265 222 171 274 275 238 180 kW 22.4 22.6 23.1 23.7 22.6 22.7 23.3 23.9 22.8 22.9 23.4 24 23 23 23.5 24.2 23.2 23.2 23.6 24.2 TC 233 243 266 289 242 247 270 295 250 252 273 299 256 258 277 303 264 265 280 306 105 SHC 233 218 182 145 242 233 194 152 250 248 206 159 256 257 217 166 264 265 232 176 kW 24.9 25.1 25.6 26.2 25.2 25.3 25.8 26.3 25.4 25.4 25.9 26.5 25.6 25.6 26 26.6 25.8 25.8 26.1 26.7 TC 225 232 254 ' 277 234 236 258 281 241 1 242 261 1 285 247 1 247 264 288 254 255 267 291 115 SHC 225 214 178 140 234 228 189 148 241 241 201 155 247 247 211 162 253 255 227 171 kW 27.9 27.9 28.5 29 28 28.1 28.6 29.2 28.2 28.2 28.7 29.2 284 28.4 28.8 29.3 28.7 28.7 28 -9 29.5 TC 216 221 241 263 224 225 245 267 231 231 248 269 237 236 251 273 243 242 253 276 125 SHC 216 208 173 136 223 221 184 142 230 231 196 149 236 236 206 157 243 242 221 166 kW 30 -9 31.1 31.8 32 31.2 31.2 31.7 32.2 31.4 31.4 31.7 32.3 31.6 31.6 31.9 32.3 31.7 31.7 31.9 32.5 • 50 • • OPTIONAL: ACCESSORIES CONCENTRIC TERMINATION KIT VENTING / AIR INLET TERMINATION CAP Contains concentric termination assembly, concentric to Vent or air inlet cap for single wall vent pipe. co- linear adapter, one linear foot of direct vent pipe and two draft See Optional Accessories tables. hood connectors. Kit requires single hole penetration of roof or wall for installation. See Optional Accessories tables. LPG /PROPANE CONVERSION KIT CONCENTRIC PIPING KIT Conversion kit is required for field changeover from natural gas. 18 in. (457 mm) long sections of direct vent pipe for use with See Optional Accessories tables. Concentric Termination kits. Refer to venting tables in this bulletin to determine pipe size THERMOSTAT needed and proper termination kit required. See Thermostat bulletins in Controls section and Lennox Price See Optional Accessories tables. Book for a complete list of thermostats. VII -1 OPTIONAL ACCESSORIES Model No. TUA045S TUA060S TUA075S TUA100S TUAl25S Air Inlet Termination 3 in. (76 mm) 82M90 - - - - - - - - - - - - Cap 4 in. (102 mm) - - - 82M91 82M91 82M91 82M91 Concentric Piping 4 in. (102 mm) 82M85 - - - ■ - - - - - - - - - Kit 5 in. (127 mm) - - - 82M86 82M86 82M86 82M86 Concentric Horizontal 82M87 82M88 82M88 - - - - - - Termination Kit Vertical 82M87 82M88 82M88 82M88 82M88 LPG /Propane Kit 82M93 82M93 82M93 82M94 82M94 Venting 3 in. (76 mm) 82M90 - - - - - - - - - - - - Termination Cap 4 in. (102 mm) 82M91 82M91 82M91 - - - - - - 5 in. (127 mm) - - - 82M92 82M92 82M92 82M92 OPTIONAL ACCESSORIES Model No. TUA150S TUA200S TUA250S TUA300S Air Inlet Termination Cap 4 in. (102 mm) 82M91 82M91 82M91 82M91 Concentric Piping Kit 5 in. (127 mm) 82M86 82M86 82M86 - - - Concentric Termination Kit Horizontal Only 82M89 82M89 82M89 - - - LPG /Propane Kit 82M94 82M95 82M94 82M95 Venting 5 in. (127 mm) 82M92 82M92 82M92 - - - Termination Cap 6 In. (127 mm) - - - - - - - - - 82M96 REQUIRED OUTDOOR VENTILATION AIR IN ACCORDANCE WITH TABLE 403.3 2004 OMSC UNIT AREA SQUARE PEOPLE NUMBER OF 1/2 OCCUPANT O.S.A. CFM PER MIN. SERVED FOOTAGE PER 1000 SQ -FT PEOPLE LOAD PER SEC. 403.3 CFM / SQFT PERSON O.S.A. CFM GP -1 GREEN RM 15 370 0.20 74 RR2 19 63 75 OFFICE 20 154 .7 • 1 0.539 -- 20 11 OFFICE 21 106 7 1 0.371 -- 20 7 OFFICE 22 108 7 1 0.378 -- 20 8 OFFICE 23 110 7 1 0.385 -- 20 8 OFFICE 24 112 7 1 0.392 -- 20 8 ' OFFICE 25 630 7 4 2.205 -- 20 44 UTILITY 26 188 0.05 9 STORAGE 27 55 0.15 8 RR3 28 20 75 GP -2 HALL 29 222 0.05 11 RR1 30 28 75 WOMEN 31 188 225 MEN 32 164 375 CONFRENCE 34 280 50 14 7 -- 20 140 OFFICE 35 92 7 1 0.322 -- 20 6 OFFICE 36 94 7 1 0.329 -- 20 7 OFFICE 37 104 7 1 0.364 -- 20 7 GP -3 HOUSE 11 3458 150 519 259.35 -- 15 3890 STAGE 12 1384 70 97 • 48.44 -- 15 727 STOREAGE 14 294 0.15 44 GP-4 CONSESSION 33 1092 60 66 32.76 -- 20 655 GP -5 LOBBY 10 728 150 109 54.6 20 1092 TOTAL ' . - 10044 -- 815 -- -- -- 7582 GAS PIPE CALCULATIONS GAS INPUT DELIVERY EQUIPMENT BTU PRESSURE GP -1 115,000 2 LB. GP-2 74,000 2 LB. GP -3 275,000 2 LB. GP -4 74,000 2 LB. GP -5 115,000 2 LB. UH -1 • 45,000 2 LB. TOTAL LOAD 698,000 2 LB. LONGEST RUN 206' GAS PIPE SIZING BASED ON 2 LB. DELIVERY AT 300' SIZE MAX. CAPACITY 1 1/2" 1,442,000 1 " 449,000 3/4" 232,000