Report &I‘f -0000 f c6„,/ co S‘A-) rA FFLE Dull Olson Weekes-IBI Group Architects,Inc. 907 SW Stark Street lol/ , Portland OR 97205 USA A P r G J/z I) ,q LTA 2 nt a fax 503 226 6950 fax 503 273 91192 ^ Revised February 3, 2014 January 27, 2014 Mark VanDomelen Building Official City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 RE: Gym and Commons Exiting @ Westside Christian High School Dear Mark, The purpose of this letter is to document our approach for meeting the exiting requirements for the high school's new gym (currently under construction)and the newly remodeled and expanded high school. As earlier stated, it came to our attention that our original exiting calculations contained some errors. With this letter, we are defining our approach to correct these errors, to bring the building into conformance with the IBC and to meet your approval. Attached, you will find a new(revised) spreadsheet that examines the exiting requirements from the Gym, exit"D" and from the Commons. Exiting from the Gym was complicated by the client's desire to have a way to secure the rest of the school from the gym. It was decided to use a coiling door between the Commons and the Gym to accomplish this goal. This limited the exit width available from the gym's exit"I"to the double-leaf door(exit"K"). Because exit"I" goes through a fire wall and becomes a horizontal exit, the capacity of exit"I" becomes limited by the size of Hall 160. Based on the area of Hall 160 and allowing 3 square feet per occupant; the capacity of exit"I" is 283 occupants. By adding another door leaf to exit"H" (resulting in three door leaves) and given the available capacity of exit"I", using the refuge area, we believe that the required exiting from the Gym has been satisfied. Exiting provided for up to 1,563 occupants and calculated occupancy of 1,474, so exits as proposed are adequate. The calculation for exit"D" is included to assist in calculating the exit width available for exiting from the Commons. Based on the exit calculations for the Commons, ate the revision of the office conference room occupancy count (using 100sf/occ) and the revision of the music occupancy count(using 50 sf/occ), we have calculated that we are just shy of the required exit width by less than 4 inches or 18 occupants. To resolve this issue, we propose we post the . - .:- • -- - - -•- - -- . Because the Commons the Auditorium are an ancillary use of the school we suggest that the Office and the Classrooms would not be occupied at the same time as the Commons and Auditorium would be occupied to capacity. This would reduce the loading on the exits by 157 from the classrooms and 37 from the office, which would more than offset the exit width we are under as calculated above and on the attached spreadsheet. We suggest that posting the occupancy of the spaces (Commons &Auditorium) at 1,265 is a reasonable number. IBI GROUP IBI Group is a group of firms providing professional services Dull Olson Weekes-IBI Group Architects,Inc.is a member of the IBI Group of firms Dull Olson Weekes•IBI Group Architects,Inc. 2 VanDomelen—February 3,2014 Hopefully this meets with your approval. Sincerely, Dull Olson Weekes—IBI Group Architects, Inc. Norm Dull Principal Attachment: Westside Christian High School Exiting Spreadsheet, February 3, 2014 J:\Prelnt\Westside Christian High School\11015 Westside Christian HS Addition-RemodellGeneral File\Code-Permits-AHJ\14-0203 VanDornelen exiting.docx Westside Christian High School February 3, 2014 Gym Exiting Required Required Total Width- Width- Contributing Occupancy Total Width Occupants Totals Multiplier Inches Exit Capacity Gym 10,307 SF 7 SF/Occ 1,472 Office 152 SF 100 SF/Occ 2 Total Occupancy 1,474 0.2 - Occupant Load Requires 4 exits Current Design 4 exits with 12 door leaves Total width 12 Ivs 32 inches 384 0.2 1,920 However: There are 3 exits to exterior(exit"H"to be enlarged to 3 leaves) 8 Ivs 32 inches 256 0.2 1,280 Therefore Exit "I" to Commons needs to accommodate 1,474 less - 1,280 equals 194 0.2 39 4 Ivs 32 inches 128 0.2 640 128 inches is greater than the 39 inches req'd. Because exit"I"goes through a "fire wall" occupants exiting through these doors are considered to have exited the building. There is a requirement for the area on the other side of the fire wall to accommodate the load from the exit through the fire wall. Below is the refuge area capacity of the Hall 160 with the coiling grill down forcing exiting through exit K. Hall 160 915 SF 3 SF/Occ 305 occs for refuge area available Weights/Fitness 1,094 SF 50 SF/Occ less 22 Total Occupant Capacity from Gym through exit "I" of Hall 160 based on Refuge 283 Area Total Occupant Exiting Capacity(of exterior doors with 3rd door leaf at exit "H") 1,280 plus 283 for Exit"I" The exit width needs to serve the exiting needs of 1,474 which is less than 1,563 therefore OK 1:\Prelnt\Westside Christian High School\11015 Westside Christian HS Add ition-Remodel\General File\Code-Permits-AH1\14-0203 Exiting Review Exit "D" I Required Required Width Width - Contributing Occupancy Total Multiplier iinches 'Exit Capacity Classrooms 5,736 SF 20 SF/Occ 287 Music 938 SF 50 SF/Occ 19 Large Group 4 Offices 2 Workroom 2 Total Occupancy 314 0.2 63 Exit Width provided 2 !vs 32 64 0.2 320 We assumed half will go toward Exit"D"and half toward Exit"A". So the occupant load from the identified rooms above toward Exit "D" and Exit"A" will be 314/2 or 157 each. 157 Remaining exit"D"capacity 163 1:\Prelnt\Westside Christian High Schoo1\11015 Westside Christian HS Additan-Remodel\General File\Code-Permits-AHl\14-0203 Exiting Review Commons Exiting Required Required Total Width Width - Contributing Occupancy SF SF/Occupant Occupants Multiplier inches Exit Capacity Stage 988 SF 15 66 Auditorium 2,544 SF 7 363 0.2 73 avail 128" _ Commons 5,850 SF 7 836 Office 1,265 Reception 261 SF 100 3 Conference 161 SF 100 2 Principal 136 SF 100 1 Staff Room 496 SF 100 5 Work Room 417 SF 100 4 Conference 229 SF 100 2 Open Office 1,872 SF 100 19 Conference 78 SF 100 1 37 _.��. .- Kitchen 625 SF 200 3 Half of Hallway Exiting into Commons 157 160 Total Occupant Load 1,462 Calculating the Req'd Exit Width Exit"D" remaining capacity 163 Exit"L" 2 !vs 32 64 0.2 320 Exit"M" 2 lvs 32 64 0.2 320 Exit"A" 4 Ivs 32 128 0.2 640 0.2 Total Exit Capacity F 1,443 Exit Capacity Exceeded 1,462 less 1,443 equals 18 The exiting capacity based on width of doors provided is under what is required for the number of occupants. 1,465 occupants have been calculated and exit capacity is 1,440 based on door width. The exiting capacity is exceeded (by 1,462 compared to 1,443 or) by 18 people which equates to less than 4 inches of exit width. J\Prelnt\Westside Christian High School\11015 Westside Christian H5 Addition-Remodel\General File\Code-Permits-AHJ\14-0203 Exiting Review