Plans Sew ELECTRIC SEPTEMBER 19, 1996 MIKE RUDD COMMUNITY DEVELOPMENT 13125 S.W. HALL BLVD. TIGARD, OR 97223 DEAR MIKE: PRECISION INTERCONNECT/FLIGHT DYNAMICS' EXISTING 1600/800 AMP SERVICE HAS REACHED ITS FULL SPACE CAPACITY. IN ORDER TO BRING THE EXISTING SERVICE UP TO CODE AND TO GAIN FUTURE CAPACITY, WE ARE REPLACING THEM WITH NEW SERVICE GEAR, 2500/1000.AMP'SPARE SPACES AND ONE NEW 800 AMP CIRCUIT BREAKER TO FEED A NEW 800 AMP SDP LOCATED IN THE MANUFACTURING AREA TO PROVIDE SERVICE FOR FUTURE EQUIPMENT. THERE IS NO ADDITIONAL SERVICE LOAD TO CALCULATE AT THIS TIME AND P.G.E. HAS PROVIDED US WITH FAULT CURRENT INFORMATION BASED ON THEIR NEWLY INSTALLED TRANSFORMER AND OUR PROPOSED NEW SERVICE. PLEASE CALL IF YOU NEED MORE INFORMATION. THANK YOU SINCERELY, STONER FL.ECTRIC, INC. 47,-eq 2. 1�GREG L. OOLFE VICE-PRESIDENT 2701 S . 14th Portland, Oregon 97202 (503)233-3631 1-800-548-2701 1000A 2771480V 30 4W \,.___,/ 2500A 2771480V 30 4W r —1 T I^ 1 d d d d d I . SPACE \ 200A \ 400A SPACE SPACE \ 400A \ 400A 800A 200A CT CT SECTION SECTION I l L I r1�_ L J TO EXISTING PANELS TO EXISTING PANELS (2)-3'C. TO EXISTING _ w/(4)-500 MCM PANEL TO SOP #4 Cu TO GROUND ROD #4 Cu TO GROUND ROD for future extruders C 1/0 Cu GROUND 1/0 Cu GROUND n t( TO WATER TO WATER 0 ' --------C----- CI) \ t FROM TRANSFORMER (by PGE) -_J L—— FROM TRANSFORMER (by PGE) FAULT CURRENT CALCULATIONS CITY OF TIGARD PER BRIAN MOORE, PGE 590-1351 p.1 proved .••• """""" [ � Conditi0natl�,r Approved.......... CUSTOMER: FLIGHT DYNAMICS CUSTOMER: PRECISION INTERCONNECT For onl the work described in: ADDRESS: 16600 SW 72nd BLDG. #10 ADDRESS: 166L0 SW 72nd PERMIT NO--P�--t ............•.[ ]: PORTLAND, OR 97224 PORTLAND, OR 97224 See totter to Follow...•.• .. Attach....... . ... .. ..... ..... TRANSFORMER KVA: 2500 KVA TRANSFORMER KVA: 2500 KVA - � �` IMPEDANCE: 5.125% IMPEDANCE: 5.125% lob Addrr�ss Date: G SECONDARY L—L VOLTAGE: 480V SECONDARY L—L VOLTAGE: 480V WIRE LENGTH: 25 feet WIRE LENGTH: 25 feet WIRE SIZE: 350 MCM AL WIRE SIZE: 350 MCM AL NUMBER OF RUNS: 4 RUNS NUMBER OF RUNS: 4 RUNS SERVICE UPGRADES WIRE IMPEDANCE R: 0.049 OHMS/1000' WIRE IMPEDANCE R: 0.049 OHMS/1000' WIRE IMPEDANCE X: 0.037 OHMS/1000' WIRE IMPEDANCE X: 0.037 OHMS/1000' FAULT CURRENT: 44,181 AMPS FAULT CURRENT: 44,967 AMPS PRECISION TNT. - FLIGHT DYNAMICS SW 72nd AVENUE PORTLAND, OREGON 97224 STONER ELECTRIC 2701 SE 14TH AVENUE PORTLAND, OREGON 97202 C503)233-3631 scA1.E' NONE DRAWN BY' DW CHEMED GV DRAVING NUMBER. PROJECT NO, 29483c REVISED DATE' 9/20/96 , 1 __` %//f�/////////// BILL OF MATERIAL CKT# - QTY. DESCRIPTION CATALOG # LOAD LUGS AIC r 1-3 3 100 AMP BREAKER HED63B100 1 (1) #14-2/0 42K 20" r 4 1 100 AMP SPACE ONLY HED6 5 1 200 AMP SPACE ONLY FXD6 "'- 6 1 1400 AMP SPACE ONLY ;JXD6 1 circuit # 100/3 1 1 10013 2 NOTES: 90" 100/3 3 100 CONSTRUCTION SWITCHBOARD IS BUILT AND LABELED PER UL 891 IN EFFECT AT THE TIME OF space 1 4 STANDARD MANUFACTURE. 200 space 5 INCOMING SERVICE AMPERES: 800 400 VOLTS: 4801277 space 6 SYSTEM: 3 PHASE 4 WIRE INTERRUPTING THE SHORT CIRCUIT INTERRUPTING CAPACITY IS EQUAL TO THE LOWEST SHORT CIRCUIT RATING RATING OF THE DEVICES INSTALLED,OR THE LIMITATIONS OF THE BUSSING STRUCTURE, ---- --- - -- - - WHICH EVER IS LESS. AT THE TIME OF MANUFACTURE,THE LOWEST RATED INSTALLED DEVICE IS 30,000 AIC BUSSING STRUCTURE RATED AT 50000 AMPS 38" ENCLOSURE ENCLOSURE IS NEMA TYPE 1 FOR INDOOR APPLICATION. CUBICAL,FRAMES AND COVERS CONSTRUCTED FROM CODE GAUGE STEEL- LIMITED ENTRY, 10" HEIGHT BETWEEN FLOOR AND BOTTOM OF BREAKER OR SWITCH ENCLOSURE FINISH ANSI 61 LIGHT GRAY PAINT. 4 3" METAL STRUCTURAL EDGE TERMINATIONS ACCESSIBLE FROM THE FRONT. BUSSING ALUMINUM,SIZED ON A BASIS OF 65 DEGREE C MAXIMUM TEMPERATURE RISE. 800A M.L.O. ' SERVICE UTILITY 100/3 100/3 CT COMPARTMENT PER EUSERC U.G.P.S. PER EUSERC 100/3 100 amp space only ,JOB NAME: PRECISION INTERCONNECT 200 amp space only TITLE: 800 AMP SUB DISTRIBUTION BOARD CUSTOMER: STONER ELECTRIC 400 amp space only P.O.# & DATE OF DRAWING 06/15/96 DWG. # MFG. LOC. PORTLAND, OR _ ___ GND GND GND GND SIEMENIS ENERGY AND AUTOMATION, INC. ■ ■ '-w . • BILL OF MATERIAL CKT # : QTY. DESCRIPTION ; CATALOG # LOAD LUGS l AIC r��������� xez./ /`�/ ff/i ��`f������� 2 !200/3 BREAKER IHFD63B200 6-350 65 K . 38" j 3 1400/3 BREAKER 'HJD63B400 6-350 65 K 1 800/3 BREAKER LMXD638800 (2) 1-500 MCN 50 K /� / // // � 1� tjl� 3 400 AMP SPACE ONLY HJD63 _ _ — 1 --_ - L 1 400/3 IT I CT SPACE ONLY --- - r COMPARTMENT COMPARTMENT 400/3 (J) 400/3 3 j SPACE ONLY ' ‘rir In 90" 200/3 400/3 /Opt ( ., NOTES: I i\e/ kap r 1 , I ( ) 400/3 , ;• a 400/3 1000 AMP 2500 AMP I I `1 \k, CONSTRUCTION SWITCHBOARD IS BUILT AND LABELED PER UL 891 IN EFFECT AT THE TIME OF ,hL �y STANDARD MANUFACTURE. SPACE 480/277 480/277 `.: ONLY 800/3 ti Ct _ "i INCOMING SERVICE AMPERES: 2500 AND 1000 SERVICES VOLTS: 480/277 UNDERGROUND UNDERGROUND 200/3 PULL PULL SYSTEM: 3 PHASE 4 WIRE SECTION H SECTION INTERRUPTING THE SHORT CIRCUIT INTERRUPTING CAPACITY IS EQUAL TO THE LOWEST SHORT CIRCUIT RATING RATING OF THE DEVICES INSTALLED, OR THE LIMITATIONS OF THE BUSSING STRUCTURE, WHICH EVER IS LESS. AT THE TIME OF MANUFACTURE.THE LOWEST RATED INSTALLED I DEVICE IS 50,000 AIC BUSSING STRUCTURE RATED AT 100.000 AMPS 38" 46" 46" 38" ENCLOSURE ENCLOSURE IS NEMA TYPE 1 FOR INDOOR APPLICATION. CUBICAL.FRAMES AND COVERS LIMITED ENTRY, 10" HEIGHT BETWEEN FLOOR CONSTRUCTED FROM CODE GAUGE STEEL. AND BOTTOM OF BREAKER OR SWITCH ENCLOSURE FINISH ANSI 61 LIGHT GRAY PAINT. 3" METAL STRUCTURAL EDGE TERMINATIONS ACCESSIBLE FROM THE FRONT. 1000 AMP 480/277 2500 AMP 480/277 BUSSING ALUMINUM,SIZED ON A BASIS OF 65 DEGREE C MAXIMUM TEMPERATURE RISE 3 PH 4 WIRE 3 PH 4 WIRE SERVICE UTILITY 400 SPO 400 SPO CT COMPARTMENT PER EUSERC 400/3 U.G.P.S. PER EUSERC 4 400/3 400/3 - - 200/3 400 SPO JOB NAME: PRECISION INTERCONNECT-PLANT #1 _ 4 800/3 TITLE: UTILITY --- — CUSTOMER: STONER ELECTRIC _ INCOMING P.O.# 07/01/96 200/3 DWG. # - rev #1 07/03/96 MFG. LOC. GND GND GND GND SIEMENSENERGY AND AUTOMATION. INC.