Loading...
Correspondence (2) q% Form 2a Project Name: Dick's Sporting Goods FILE COP Page: 1 SUMMARY • .� -3'i.^.�i:_- v'�.l�W':.��1T i;:I114�..�'Fa.Yi w- "�.' �� 4Ai;� � li_aw ~ 4 # .. Project 1. Project Name Dick's Sporting Goods 2. Project Address cmp �. .SSW Washington Square Rd. 3. City/Town Tigard 5. County ( Washington J 4. Building, Gross Area (ft2) 94,154 sq ft 6. No. of Floors I 2 7. Construction Site Elevation Above 2,000 ft? ❑ YES p NO Attached Chapter Type ID Description Attach Form an d Building Envelope Form 3a Building Envelope - General El Worksheets 3b Prescriptive Path - All Climate Zones * CodeComp Report for Simplified Trade -off ❑ * In lieu of 3b * Floppy disc with .occ CodeComp file El Check boxes to Worksheet 3a Wall U- factor indicate attached 3b Roof U- factor forms and 3c Floor U- factor ❑ worksheets 3d Window /Skylight Schedule ❑ Systems Form 4a Systems - General 4b Complex Systems ❑ Worksheet 4a Unitary Air Conditioners - Air Cooled El 4b Unitary Air Cond. - Water & Evap Cooled ❑ 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat Pump - Water Cooled ❑ 4e Packaged Terminal A.C. - Air Cooled 4f Packaged Terminal Heat Pump - Air Cooled ❑ 4g Water Chilling Pkgs - Water & Air Cooled ❑ 4h Heat Rejection Equipment ❑ 4i Boiler - Gas -Fired and Oil -Fired ❑ 4j Furnace & Unit Heaters - Gas and Oil -Fired 4k Simultaneous Heating and Cooling ❑ 41 Air Transport Energy ❑ 4m Natural Ventilation El Lighting Form 5a Lighting - General [� 5b Interior Lighting Power - Tenant Method ❑ 5c Int. Ltng. Power - Space -by -Space Method El Worksheet 5a Lighting Schedule 5b Interior Lighting Power Applicant 7. Name Ernest Williams 10. Telephone 256 - 533 -6484 8. Company Sebring Engineering, Inc. 11. Date 03/29/07 9. Sig �i►_ y)di Attached No. of Pages Description of Documentation Document 4 "Cut Sheets" for HVAC Unit and Gas Heater Efficiencies - ation 1 "Cut Sheets" for Window U- factors wmpu9I wim v�7.71., enet,Lnre vl►u itua Form 3a Project Name: Dick's Sporting Goods Page: BUIL XNG L_ PE a GENERAL - : = ^ »�x6 . di+ " #:?c �,.: ..:,: r:`y.,Y.�::ti.M. r+"x , . 3rfs; �? ' _F_,:c...- !s�:."S "�:'L....F= i s?.,_�+. ra .err. R:�C k: }`,'.: "._ > . ,... .... 7. x.,1' 0 - 7.!S�s_.,. !... SF. Check all boxes 1. Exceptions (Section 1312) that apply. ❑ No Envelope Components. The building plans do not call for new or altered building envelope components, e.g., walls, floors or roof /ceilings. ❑ A Non - conditioned Building. The proposed structure has no spaces heated or cooled by an HVAC system. Exceptions ❑ Exception. All new or altered building envelope components do not comply with the Discussion of qualifying requirements, Section 1312, but qualify for Exception: 0-1 ❑ -2 0-3 0 -4 ❑ -s exceptions in Portions of the building that qualify: instructions section. Plans /Specs Show compliance by The plans /specs show compliance in the following locations: including a drawing sheet, detail number, 2 Air Leakage (Section 1312.1.1) specification section and;or subparagraph. El Complies. Plans require penetrations in building envelope are sealed and windows and doors are caulked, gasketed or weatherstripped. The plans /specs show compliance in the following locations: Drawing A -5.1 and specification section 08810.2.07, 08410.3.03.D and 08305.3.03.A 3. Suspended Ceiling (Section 1312.1.2.1) El Complies. Building plans do not show suspended ceilings used to separate conditioned space from unconditioned space. No exceptions permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) O Complies. The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. ❑ Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans/specs show compliance in the following locations: 5. Moisture Control (Section 1312.1.4) ❑ Complies. A one -perm vapor retarder is installed on the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover installed in the crawl space of both new and existing buildings where insulation is installed. The plans/specs show compliance in the following locations: El Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable exception. Section 1312.1.4, Exception: 0-1 0 .2 Portions of the building that comply: Total bldg. is slab -on -grade Climate 6. Climate Zones Zones !] Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, Tillamook, Yamhill, or Washington. _; ❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or �.. higher in Zone 1, are in Zone 2. , ra • • 3-1 Compliance with OSSC, effective 01/01/05 1 Form 3b Project Name: Dick's Sporting Goods Page: 3 PRESCRIPTIVE PATH Part g o f 4 CLIMATE ZONE 1 Exterior Wall 1 - Window Area Area Glazing Maximum Glazing (total rough frame ft2) (gross ft2) % Fraction Complies • Glazing Conditioned Percent Space 23,640 ' + 141,040 X 100 = 16.8% Yes Calc- Semi - ulation Conditioned + X 100 = 0.0% Yes Space See instruction section for a Conditioned discussion of Mechanical + X 100 = 0.0% Yes glazing percent Penthouse calculahon Windows Window Max Minimum Shading Window Minimum From Work- (from Worksheet 3d) U- Factor' . Assembly ttroin Worksheet Coefficient Assembly sheet 3d, place the highest N/A N/A CI N/A N/A 2 Overall Window U -Value Complies N/A SC Complies N/A U factor and highest Center-of Required Minimum Double - glazed with 0.5 inch Glass SC. Or Assembly (Fixed airspace, low-e coating, alum Required Minimum Tinted outdoor pane check minimum Windows) frame Assembly assembly and Identify window. Required Mini mum Assembly Double - glazed window with a (Operable 0.5 inch air space, low-e Windows and coating and thermally broken Curtainwall) frame The plans /specs show window compliance in the following locations: Drawing A -5.1 and specification section 8810.2.04 & .06 for all locations Notes ' From Worksheet 3d, place the highest Overall Window U -factor or check (Minimum Assembly) See "Window Requirements' in table on the following page for specific MA requirements Excel version will automatically Insert minimum assembly requirements or greatest U -value from Worksheet 3d 2 From Worksheet 3d, place the highest 'center-of-glass" shading coefficient (SC) for glass or check MA (Minimum Assembly) See - Window Require- ments' In following table for specific MA requirements. Excel version will automatically Insert minimum assembly requirements or greatest SC from Worksheet 3d. Shading Coefficient (SC) can be calculated from Solar Heat Galn Coefficient using the equation SC = SHGC • 0 87 Manufacturers data may also be used to document SC. Walls R -Value Wall / Insulation Type Insulation Only U- Factor See instructions 1 6: Metal Studs'@ 16° O.C. WBatt Ftsul. , for a discussion 22 or of wall require- merits. or J or or J Or or Below- R -Value Grade Walls Insulation Only U-Factor See instructions Below -Grade Walls (Mm. R - 7.5) (Max. 0.11) r y. for a discussion of None . + • requirements. or *: 17-T;,' Notes ' Submit Worksheet 3a for each calculated assembly U- factor ,. ; , 3 -2 Compliance with OSSC, effective 01/01/05 1 Form 3b Project Name: Dick's Sporting Goods Page: 4 PRESCRIPTIVE PATH Part 2 of 4 Code Requirements - Zone 1 Discussion of these requirements in the instruction section. ZONE 1 Wall Requirements Window Requirements Max. Max. Glazing R -Value Shading Fraction Wall / Insulation Type Insulation Only U- Factor Max. U- Factor Coefficient Up to 15% CMU 'Masonry w /integral loose fill insulation N/A w 0 .300 Masonry or concrete w /cont. exterior insulation 1.4 Or 0.300 0.540 0.57 CMU Masonry w /integral rigid fill insulation N/A or 0.210 Masonry or concrete w/interior insulation 11 or 0.130 Up to 30% Masonry or concrete w /cont. exterior insulation 2.8 or 0.210 0.540' 0.57 Frame (wood or metal framing) 13 or 0.130 Other (provide short description) 13 or 0.130 CMU Masonry w /integral rigid fill insulation N/A or 0.210 r Masonry or concrete w /interior insulation 11 Or 0.130 Up to 40% Masonry or concrete w/cont. exterior insulation 2.8 Cr 0.210 0.37010 0.3510 Frame (wood or metal framing) 13 Or 0.130 Other (provide short description) • 13 or 0.130 Code Requirements - Zone 2 Discussion of these requirements in the instruction section. ZONE 2 Wall Requirements Window Requirements Wall / insulation Type Max Max. Glazing Fraction" R -Value U- Factor Max. U- Factor Shading Insulation Only Coefficient U , CMU 'Masonry w /integral loose fills insulation N/A Or 0.300 p to 15% /o Masonry or concrete w /cont. exterior insulation 1.8 or 0 270 0.500" 0.57" CMU Masonry w /integral rigid fill insulation N/A or 0.160 Masonry or concrete wlinterior insulation 13 or 0.090 Up to 25% Masonry or concrete w /cont. exterior insulation 4.3 Or 0.160 , 0.500 0.57 Frame (wood or metal framing) 19 or 0.090 Other (provide short description) 19 or 0.090 CMU Masonry w/iintegrai rigid fill insulation N/A or 0.160 Masonry or concrete wlnterior insulation 13 or 0.090 Up to 33% Masonry or concrete w /cont. exterior insulation 4.3 or 0.160 1z 0.4312 Frame (wood or metal framing) 19 or 0.090 0.370 0.43 Other (provide short description) 19 or 0.090 Notes ° The Simplified Trade-off Approach must be used if glazing fraction exceeds allowable percentages. 5 Minimum weight of masonry and concrete walls = 45 Ib/ft2 of wall face area a All cores to be filled. At least 50% of cores must be filled with vermiculite or equivalent fill insulation 7 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double -glazed window with a 0.5 Inch air space, low coating and aluminum frame. MA shading coefficient description Is a tinted outboard pane of glass. For Operable Windows or Curtalnwall: double -glazed window with a 0 5 inch air space, low-e coating and thermally broken frame MA shading coefficient descnption is a tinted outboard pane of glass a All cores except bond beams must contain rigid insulation inserts approved for use In reinforced masonry walls ° Batt Insulation Installed In metal or wood frame walls shall be insulated to the full depth of the cavity, up to 6 Inches In depth 10 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double -glazed window with a 0.5 inch argon filled space, low-e coating (e <= 0 05) and thermal break frame For Operable Windows or Curtainwall: only use Max U- Factor. MA shading coefficient description Is a 0 25 -Inch thick glass with low -e coating (er 0 05) with a tinted outboard pane I Prescriptive MA (Minimum Assembly) - For Fixed Windows: double- glazed window with a 0 5 Inch air space, low-e coating and aluminum frame. For Operable Windows or Curtalnwall: double -glazed window with a 0 5 Inch air space, low-e coating (a <= 0 1) and thermally broken frame. MA maximum shading coefficient description is a tinted outboard pane of glass. ,s`' 12 Prescriptive MA (Minimum Assembly) - For Fixed Windows, a double - glazed window with a 0 5 Inch argon filled space, low-e coating (e <= 0.05) ,., g f l • 0' , and thermal break frame For Operable Windows or Curtalnwall, only use Max U- Factor. MA shading coefficient description is a 0.25 -Inch thick gib' :.,. : J class with low-e coatna (e <r: 0 051 Vii. 3 Compliance with OSSC, effective 01/01/05 { Form 3b Project Name: Dick's Sporting Goods Page: 5 PR CR PATH Part 3 of 4 Roofs/ R -Value Insulation Only . U - Factor Ceilings Roof / Ceiling" (Min R -19) (Max. 0.050) See instructions EPDM Roofing System ' for a dicussion of 9 Y 24 or roofs/ceilings. Notes 1 1 Write -in a short description for assembly with the lowest Insulation R -value or the highest assembly U -factor 12 Submit Worksheet 3b for each calculated roof /ceiling assembly U- factor Skylight Area Roof Area Skylight Maximum Skylight (total rough frame ft2) (gross ft2) % 13 Fraction Complies Skylights Conditioned Includes glazed Space 0 = 42,800 x 100 = I 0.0% I Yes smoke vents. . Semi - See instructions Conditioned 1 + X 100 = N/A for a dicussion of Space skylights. • Conditioned Mechanical + X 100 = N/A Penthouse Skylight Area (total rough Roof /Ceiling Area Skylight frame ft2) (gross ft2) Percent" Skylights Worksheet Skylights Max Minimum Skylights Shading Minimum (from Worksheet 3d) U- Factor 14 Assembly (from worksheet 3e) Coefficient' Assembly 3d, place highest Overall Vertical #NIA ❑ #N/A N/A Window U factor and highest U - Value Complies Yes SC Complies Yes Center SC. Required Minimum Required Minimum Assembly N/A Assembly N/A (must use SC) The plans /specs show window compliance in the following locations: Code Compliance Thermal Performance Shading Coefficient Option Overall Vertical U- Factor Center of Glass SC Require- Performance U -1.230 for overall assembly in overhead plane SC -0.47 center -of -glass meats Min. Assembly Double glazed, 0.5 -Inch airspace N/A (MA) Notes 13 Skylight percentage area is based on total skylight and smoke vent rough frame area divided by total conditioned roof area. Percentage must not exceed 6 percent of total roof /ceiling area In conditioned building space. The Simplified Trade-off Approach must be used If glazing fraction exceeds allowable percentages. 14 From Worksheet 3d, place the highest Overall Vertical U -factor or write -in MA (Minimum Assembly). See 'Skylight Requirements" In table above for specific MA requirements. 15 From Worksheet 3e, place the highest "center-of-glass" shading coefficient (SC) for glass. See "Skylight Requirements" In table above for specific MA requirements Shading Coefficient (SC) can be calculated from the Solar Heat Gain Coefficient using the equation SC = SHGC + 0 87 Manufacturers data may also be used to document SC r i'e 3 , Compliance with OSSC, effective 01/01/05 Form 3b Project Name: Dick's Sporting Goods Page:l6 PRC f' ' PTIVE PATH Part 4 of 4 Floors See instructions R -Value for a dicussion Floors over Unconditioned Spaces insulation Only U- Factor of floors. Non- Heated Slab -On -Grade 10 or Heated Concrete Slab Edge R -Value Insulation Only Heated Slab -on -Grade (Section 1312.1.2.4) ❑ Complies. Building plans show insulation extending downward from the top of the slab a minimum distance of 24 inches or downward and under the slab for a combined minimum distance of 24 inches or to the bottom of the thickened edge of the of slabs used as a foundation. The plans /specs show compliance in the following locations: Drawing A -9.3 and specification section 0723.2.01.8 Notes 1e Write -in a short description for assembly with the lowest insulation R -value or the highest assembly U- factor. 17 Submit Worksheet 3c for each calculated floor assembly U- factor. IS Write -in a short description for Heated Slab, which has heat. integrated Into slab such as hydronic heal. If more than one floor type, enter the lowest Insulation R -value or the highest component U- factor of any floor Code Compliance Options lzegnire- Min. R -Value Max. U- Component Insulation Only Factor meats Floor over Unconditioned Spaces 11 I or I 0.070 Climate Climate Component Zone 1 Zone 2 Heated Concrete Slab Edge, Min. R -Value I 7.5 J or I 10.0 Doors See instructions 1a R -Value U- Factor for a dlcussion of Doors Insulation Only Center -of -Panel opaque, with leaf width greater than 4' (Min. R -5) (Max 0 20) doors. - Access Doors R -5 or Notes 1B Write -In a short description for Doors. If more than one door type, enter the lowest Insulation R -value or the highest center -of- panel U- factor of any door The following doors are exempt from door and window U- factor and shading coefficient requirement 411 • O Compliance with OSSC, effective 01/01/05 Worksheet 3a Project Name: Dick's Sporting Goods Page: 7 Wall U- factors See Tables 3a through 3d for R- Values of building materials Wall Assembly 1 - ID Ground Level Brick Wall • (a) (b) ( c) (d) - Layer Description Detail R -value Exterior Moving Air 0 ` " ,1 A Brick (Masonry) _ Brick, fired clay4 ",120lb/113 II ., 1 B i Air Space _ Air Layer 3/4" Vertical W alls 0.94 • ,c•• 1I . 1 C Other 6" Batt Insulation 2200 II 1 D Interior Finish j Gypsum or plaster board 0.5" • .� r 11 1 E -i J l t:.1� i I G i H - j 1 1� i J ; , i Interior Still Air 0 1. Total column (d) 24.89 • 2. Assembly U- factor (Invert the amount in line 1) 0.040 Wall Assembly 2 - ID Upper Level Wall (a) (b) (c) (d) Layer Description Detail R -value Exterior Moving Air 0 1� I A Exterior Finish _ - Periite aggregate, vermiculite aggregate - - 0.44 1 ' II 1 B Other w 6" Batt Insulation 22.00 II 1 c Interior Finish . Gypsum or plaster board 0.5" , - 0.45 11 1 E 1 1 F • 1 G I Interior Still Air I 0.68 1. Total column (d) 23.74 4116 , 2. Assembly U- factor (Invert the amount in line 1) 0.042 1 Add Additional Wails r i - > 3 -7 Compliance with OSSC. effective 01101105 Worksheet 3b Project Name:IDick's Sporting Goods Page: 8 Roof U- factors See Tables 3a through 3d for R- Values of building materials Roof Assembly 1 - ID Roof System (a) (b) (c) (d) Layer Description Detail R -value xterior Moving Air 0.17 A Other j EPDM Roof System 1 -- 0.16 B Other , Polyisocyanurate foam insulation board 24.00 MEI c Other @ Steel Form Deck . 0.00 1D - i G . J J 1 H Interior Still Air — 0.61 1. Total column (d) 24.94 2. Assembly U -factor (Invert the amount in line 1) 0.040 Roof Assembly 2 - ID (a) (b) ( (d) Layer Description Detail R -value erlor Moving Air 017 1 9 „ .I 1 il MI ID .' 1 ;� , j • 1 1 • MEI= 3 . ..,... Interior I Still Air I 0.61 1. Total column (d) tl�s ;;`` „ s` i -�r� 2. Assembly U- factor (Invert the amount In line 1) ■ ifir Add Additional Roofs . I 3 -7 Compliance with MSC. effective 01/01/05 Form 4a Project Name: Dick's Sporting Goods Page: 9 SYSTEMS - GENERAL +S •- $.v ^ .d - +-�_.'!: .. F.?'�'�'. i.S; �. 5.• 7 w frfr ifrt�' tr , 'sv .dA` � �3. e e �a,'pacr i't_•',;'i'^�:.. ���:i.'r,r , SK,:, >az- Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet, detail number, exceptions on page 4 -25 specification section and subparagraph 1. Applicablity `Section 1317) Is this form required? o Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) • ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ - ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ - ❑ -2 ❑ -3 O Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) 0 Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. ❑ Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ •ab ❑ -4c ❑ - ad 0 -4e ❑ -4t ❑ -4g ❑ -4h ❑ 0 -4 4. Duct Insulation and Sealing (Sections 1317.7 as 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. 0 Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as rewired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) ❑ No Distribution Transformers. The plans /specs do not call for new distribution transformers. Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0 0 0-4 0-5 ❑-s ❑a 0.8 0.9 0-10 ❑-, 0-12 0-13 0-14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following locations: t a s 4 -1 April 2005 Compliance with OSSC, effective 01 /01 /05 Form 4a Project Name: Dick's Sporting Goods Page: 10 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) E l Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception ❑ -t 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) • Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. 0" Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: 0 Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception ❑ -t 0 -2 The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.4 Optimum Start Controls (Section 1317.4.3.2) O Complies. Separate HVAC systems have controls capable of varying start -up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) 0 No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans /specs show compliance in the following locations: 4-2 April 2005 Compliance with OSSC, effective 01/01105 Form 4a Project Name: Dick's Sporting Goods Page: 11 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. O Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception 9-19-2 ❑ .3 ❑ -4 ❑ -5 ❑ -6 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) El Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) ❑ No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. O Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ -A ❑ -2 The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) O No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity - ,i Allowable Hot Gas Bypass Rated Cooling Capacity Max Hot Gas Bypass r , <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4-3 April 2005 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Dick's Sporting Goods Page: 12 SYSTEMS - GENERAL _ _.•,.w ..._ ,. ;:�.�zizYC: -.Kim :h.�r .' -. _.,_ .tea '-.... �'�� �Tr� r G 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. t] Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ - ❑ .2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 The plans /specs show compliance in the following locations: 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) El Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. O Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: 10.2. Motorized Damper Leakage (1317.4.3.3.2) O Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: 11. Piping Insulation (Section 1314) El No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ -1 ❑ -2 12. Occupancy Ventilation Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans/specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in the following locations: The plans /specs show compliance on the following pages: 'l 4-4 April 2005 Compliance with oSSC, effective 01/01/05 Form 4a Project Name: Dick's Sporting Goods Page: 13 SYSTEMS - GENERAL - ....i5s';5.. •ems:, - ?.:c:�FY`E_.._•' _�...;R.tY .._rte: y: lLc'' 1fit .F.:::_�,`.Yt...- ._:..T..'..{ i.s...L �•!::r2c ,.s..ii ur ^3�',...�.: 5.s�i:;ax.?rt:e 13. High Occupancy Ventilation (Section 1317.2.2) 0 Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. ❑ No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) ❑ Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) . min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception❑-+ ❑ - ❑ -3 ❑- ❑ -s ❑ -s ❑a The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) ❑ Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) o Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Compiles. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. • Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify: The plans /specs show compliance in the following locations: Sheet P-4.0 Detail 10 and Section 15 ?? 4-5 April 2005 Compliance with OSSC, effective 01 /01/05 Form 4a Project Name: Dick's Sporting Goods Page: 14 SYSTEMS - GENERAL T:4.2 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) • No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as • required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) 2 No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. • ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) O No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) O Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. The plans /specs show compliance in the following locations: 22. Outside Heating Systems (Section 1317.12) O No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 April 2005 Compliance with OSSC, effective 01/01/05 if'-. Worksheet 4e Project Name: Dick's Sporting Goods Page: F 15 I PACKAGE' TERMINAL A.C. - AIR COOLED Equipment (a) (b) (c) (d) (e) Proposed Code Enter the cooling capacity Minimum in column (c) If capacity Cooling is less than 7,000 Btu/hr, use 7,000. If above Capacity EER EER 15,000, use 15,000. Type of Equipment Equip. ID Model Designation (Btu/hr) (95 °F db) (95 °F db) • '" RTU -1 Lennox LGA -240H 242,000 11.0 -39.0 Discussion of equipment ratings and equipment RTU -2 Lennox LGA -300H 300,000 11.0 -51.4 definitions on page 4 -19. RTU -3 Lennox LGA -240H 242,000 11.0 -39.0 RTU-4 Lennox LGA -240H 300,000 11.0 -51.4 RTU -5 Lennox LGA -300H 300,000 11.0 -51.4 f Units Installed in New RTU -6 Lennox LGA -300H 300,000 11.0 -51.4 Construction RTU -7 Lennox LGA -300H 300,000 11.0 -51.4 RTU -8 Lennox LGA -300H 300,000 11.0 -51.4 RTU -9 Lennox LGA -120H 120,000 11.0 -13.1 RTU -10 Lennox LGA -210H 210,000 11.5 -32.2 Replacement of Existing Units (installed prior to 10/01 /03) f }"fi: ,. '.� r. A. Required Indicate source of information Documentation ❑ ARI Unitary Directory, Section AC, page: ❑ ARI Applied Products directory, Section ULE, Page: - El Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets ") Code Calculate the code minimum EERs from the formulas below using the cooling capacity in column I c i. - Required Enter the results in column (e) elf New Construction. EER © 95F Test Conditions = 12.5 -(0 213x Cap/1000) Efficiencies Replacement Units . EER ® 95F Test Conditions = 10.9-(0213x Cap/1000) F, 4 -15 . Compliance with OSSC, effective 01/01/05 Worksheet 4j Project Name: Dick's Sporting Goods Project p 9 Page: 16 FURNACE & UNIT HEATERS - GAS & OIL -FIRED *:„�V,.:,-„.„,n'•W4 y ::�; x� ;. "+ x��z7 x ?.Y':a+..t er.+ �}:S -':4 f-+ ,°3v F ��'�,,�F. � rr �� .... -, :;e��...._�tte� :�C k..: �"tq` -r rs €ty'"�.�.. ,yl,`s � _ _ . a.. - Equipment (a) (b) (c) (d) (e) Proposed Discussion of equip- Heating Minimum Minimum • ment ratings and Capacity EC ET Minimum Compliance • equipment definitions (Btu /hr ) Equip. ID Model Designation (%) ( %) AFUE ( %) Schedule (A - E) on page 4 - 19. 9 /o RTU -1 Lennox J..GA -240H 480,000 80% 80 %Ec RTU -2 Lennox LGA -300H 480,000 80% 80 %Ec RTU -3 Lennox LGA -300H 480,000 80% 80 %Ec RTU-4 Lennox LGA -240H 480,000 80% 80 %Ec RTU -5 Lennox LGA -300H 480,000 80% 80 %Ec RTU -6 Lennox LGA -300H 480,000 80% 80 %Ec RTU -7 Lennox LGA -300H 480,000 80% 80 %Ec RTU -8 Lennox LGA -300H 480,000 80% 80 %Ec RTU -9 Lennox LGA -120H 240,000 80% 80 %Ec RTU -10 Lennox LGA -210H 480,000 80% 80 %Ec UH -5 LF24 -200A 195,000 80% 80 %Et UH-6 LF24 -200A 195.000 80% 80 %Et Required Indicate source of information Document- 0 GAMA Consumer Directory, page(s): ation 2 Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets "). Code Required Capacity .(Btu /hr) Compliance But not Efficiencies Schedule Equipment Type , Over over Minimum Efficiency This schedule of equip Gas Fired Warm -Air Furnaces 0 225,000 78% AFUE or 80% E ment efficiencies was & Combustion Furnace /AC o reformatted from code, 225,000 80 /o E Table 13 -P. Oil -Fired Warm Air Furnaces 0 225,000 78 %AFUE or B0% E B & Combustion Furnace/AC 225,000 - 81% E C Gas Fired Duct Furnaces ALL 80% E, ' D Gas Fired Unit Heaters ALL 80% E, E Oil -Fired Unit Heaters ALL 80% E, /i 4 -20 Compliance with OSSC. effective 01/01/05 Form 5a Project Name: Dick's Sporting Goods Page: 17 LIGHTING - GENERAL 1. Interior Exceptions (Section 1313.1) ❑ No Interior Lighting. The building plans and specifications do not call for new or altered interior lighting. Skip to item 5, Exterior building Lighting - General, below. Exceptions ID Exceptions. 1. The building or part of the building qualifies for an exception from code lighting Discussion of qualifying requirements. Applicable code exception is number: exceptions in instructions section 2. Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number: 2.7 Emergency Lighting Areas of the building and equipment that qualify for any exceptions: Plans /Specs Show compliance by including a All drawing sheet, detail number, • and/or specification section and subparagraph 2. Local Shut -off controls (Section 1313.3.1.1) ❑ Complies. At least one local shut -off lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control(s) is detailed in the building plans on drawing number: 1 p Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313.3.1.1, Exception: 4. single- tenant retail space Portions of the building that qualify: 1AII 3. Automatic Shutoff Controls (Section 1313.3.1.2) ❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space is not over 5,000 square feet. No offices less than 300 square feet, meeting or conference rooms, or school classrooms. t7 Compiles. All interior lighting systems are equipped with a separate automatic control to shut off lighting during unoccupied periods. Offices less than 300 square feet, meeting and conference rooms, and school classrooms shall be equipped with occupancy sensors that comply with Section 1313.3.1.2.1. Compliance details in plans /specs: Drawing E -5.0 Details 3 and 4 ❑ Exception. The building or part of the building qualifies for an exception. The applicable code exception is Section 1313.3.1,2, Exception: Portions of the building that qualify: All 4. Daylighting Controls (1313.3.1.3) l7 No classrooms or atriums with skylights or window to wall ratio greater than 50 %. ❑ Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are equipped with automatic daylight sensing controls, as required by Section 1313.3.1.3.1 and Section 1313.3.1.3.2. The daylight sensors specified comply with Section 1313.3.1.3.3. Compliance details in plans/specs: Exterior Build 5. Exterior Lighting (Section 1313.5) ing Lighting O Complies. The plans do not call for use of incandescent or mercury vapor lamps for use on building extenor. is lighting directed to illuminate ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor lamps, but are the exterior of the building and specified for use in or around swimmin adjacent walkways and g pools, water features, or other locations subject to requirements loading areas with or without of Article 680 of the 2002 National Electrical Code canopies. Clock Switches 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) shall be astronomic (seasonal 0 Complies. The building plans and specifications include photoelectric and /or clock switches on all exterior correcting) type with separate lighting systems which are designed and programmed to extinguish lights when daylight is present, as programs for each day of the required by Section 1313.3.2. week and shell store energy to maintain timekeeping during power outages. 7. Interior Connected Lighting Power (Section 1313.4) YESIComplles. The interior lighting power does not exceed the interior power allowance established in either the Tenant Space Method (Form 5b) or the Space-by -Space Method (Form 5c). r Tenant Space Method (Form 5b) r. Space-by-Space Method (Form 5c) 5-1 • Compliance with OSSC, effective 01/D1105 • Form 5c Project Name: Dick's Sporting Goods Page: 18 INTERIOR LIGHTING POWER - Space -by -Space Method Lighting 1 Total Interior Lighting Power Budget from Worksheet 5b -1 (Sum of Column (I)) 164,5s4 Power Budget Track Lighting 2. Total length of track lighting (ft) 1,500 • Power 3. Line 2 multiplied by 37.5 Wattsi t 56,250 4. Total amperage of circuit breaker(s) serving track lighting (amps) 120 5. Voltage of circuit breaker serving track lighting (volts) 680 6. Maximum wattage of track lighting (multiply line 4 by line 5) 81,600 7. Track Lighting Power (lesser value of line 3 or line 6) 56,250 8. Total Interior Lighting Power from Worksheet 5b-1 (Sum of Column (m)) + 97,609 Building's 9. Total Adjusted Lighting Power (line 7 + line 8) 153,859 Lighting Power 10. Does design meet budget? . Line 9 must be no greater than line 1. YES • e'i; 5-3 Compliance with OSSC, effective 015155 • Work; Project Name: Dick's Sporting Goods Page: 19 LIGHTING SCHEDULE (a) (b) (c) (d) (e) (f) Lum Luminaire Is Luminaire ID Luminaire Lamp Ballasts Power From Type Description No. Description No. Description (watts) Table 5c A Fluorescent T8 -4 foot - j 3-F32T8/30ES-ELECT NO-79W J 3 F32T8/30ES 1 Electronic Normal Output. IS 79 YES Al Fluorescent Linear Lamps T5 3-F54T5-ELECT-176W • 3 F54T5 2 Elect. Program Start 176 YES F 1 Fluorescent T8 -4 foot - 2- F32T8/30ES -ELECT NO-54W ' 2 F32T8/30ES 1 Electronic Normal Output. IS 54 YES Fl Fluorescent T8 -4 foot 2-F32T8/30ES-ELECT NO-54W • 2 F32T8/30ES 1 Electronic Normal Output. IS 54 YES G I Fluorescent Linear Lamps T5 1 3-F5475-ELECT-176W • 3 F54T5 2 Elect Program Start 176 YES GF I Track Lighting T rack Lighting _ _ - 37.5 YES GR 1 Fluorescent Linear Lam ps T5 2- F28T5- ELECT -680W - 0W 2 F28T5 . 1 Elect. Program Start 60 YES — H - 1 User Defined - - Elevator Pit incandescent - 1 60 60 NO LG Fluorescent T8 - 4 foot - 4- F32T8130ES -ELECT NO -104W • 4 F32T8/30ES 1 Electronic Normal Output. IS 104 YES LG1 Fluorescent T8 -4 foot . 2- F32T8/30ES- ELECT NO54W • 2 F32T8/30ES 1 Electronic Normal Output. IS 54 YES T i Compact Fluorescent 2D 2- CFS1OW/GR10q- ELECT -26W Z. 2 CFS1OW /GR10q 1 Electronic 26 YES T1 Compact Fluorescent 2D • 2- CFS1OW /GR10q- ELECT -26W • 2 CFS1OW /GR10q 1 Electronic 26 YES U I High Intensity Discharge - Metal Halide d 1-M400-ELECT-430W J 1 M400 1 Electronic 430 YES U2 - High Intensity Discharge - Metal Halide . 1'M1000-MAG STD -1080W • 1 M1000 1 Magnetic Standard 1080 YES U3 " Fluorescent Rapid Start T8 - 2 foot - NO-33W • 2 F17T8 1 Electronic Normal Output. RS 33 YES V1 High hten city Discharge - Metal Halide 1- M250 -MAG STD -295W _ - 1 M250 1 Magnetic Standard 295 YES yl I High Intensity Discharge - Metal Halide j 1-M175-MAG STD -205W - -j 1 M175 1 Magnetic Standard 205 1 YES Y2 I High Intensity Discharge -Metal Halide 1-M50- ELECT -58W 1 M50 1 Electronic 58 YES Y3 I High Intensity Discharge - Metal Halide 1 -M70- ELECT -86W 1 M70 1 Electronic 86 YES Z1 1 High Intensity Discharge - Metal Halide 1 -M100- ELECT -110W • 1 M100 1 Electronic 110 YES Y2A High Intensity Discharge - Metal Halide = 1-M70-ELECT-BOW • 1 M70 1 Electronic 86 YES p Fluorescent TB - 4 foot - 4 2- F32T8/30ES -ELECT NO-54W - • 2 F32T8/30ES 1 Electronic Normal Output. IS 54 YES CHAN I User Defined • CHANDERLIER • 1 600 600 NO B I Fluorescent TB -4 fOot , 3- F32T8/30ES- ELECT NO -79W :1 3 F32T8/30ES 1 Electronic Normal Output. IS 79 YES • •4 • J - LightingForms- V2.3.xls • Worksheet 5b-1 Project Name.' I Dick's Sporting Goods Page. 20 INTERIOR LIGHTING POWER Space-by-Space Method Only Skip to column (r) if using the Tenant Space Method (a) (b) (c) (d) (a) Lum ID (9) (h) h) 0) (k) Room ID (tlo Space Type Space Lighting from Quantity of oo R ot m ID any Area ype P ghti ng Power Worksheet Luminaires (or Luminaire Lighting Room Y z (Table 13-H) Type Budget 5a Column ['malt for track Power Exempt Power Total Ltg. blanks) (ft) (enter space type only once per room) LPD (b) x (6) ( lighting) (Watts) Fixtures (g) x (h) Power Each room 127 41956 Retail - Other Merchandise Sales Area 2 83,912 U -J 10 430 ❑ 4,300 40,618 must be 127 ._ _ V .I 3 295 ❑ 885 identified. 127 G -I 15 176 ❑ 2,640 Describe - - humans for each 127 - - 12 zi 8 58 ❑ 464 - Individual room in 127 • plans - 12A .1 4 86 ❑ 344 - 127 -- - GF 852 38 ❑ 31,950 - 108 2185 Active Storage 08 1,748 LG -i 26 104 ❑ 2,704 2,704 106 1454 Active Storage 08 1,163 LG1 -1 4 54 ❑ 216 1,672 For track lighting 106 - - LG J 14 104 ❑ 1,456 enter lineal feel In 134 74 Dressi g/Locker/Flain Room 0.6 44 Ti 1 column column (g) B _ 26 0 28 59 134 - - U3 - 1 33 ❑ 33 - Column (k), enter 135 74 Dressing/Locker /Feting Room 06 44 T1 •. 1 26 ❑ 26 112 sum of column g) 135 - - h3 1 86 ❑ 88 for each mom only 133 372 Active Storage 0 8 298 LG 2 104 ❑ 208 208 CCM at Post entry for the roan See 132 40 Dresstng/LockedRteng Room 0 6 24 T1 1 1 26 ❑ 26 59 example In 33 Instructions 132 - - U3 1 33 ❑ - 131 40 Dressing/Locker/Fitting Room 06 24 Ti 1 26 ❑ 26 59 131 - - U3 -1 1 33 ❑ 33 - 115 348 Actne Storage 0 8 278 LG •I 3 104 ❑ 312 312 118 273 Active Storage 0 8 218 LG 7 2 104 ❑ 208 208 117 69 Dresslng/Locker/Ftaing Room 0 6 41 LG1 . 1 54 CI 54 54 102 716 Active Storage 0.8 573 14 i 13 104 ❑ 1,352 1,352 125 44 Active Storage 0 8 35 T1 .! 1 26 CI 28 59 125 - - Lb 1 33 ❑ 33 128 44 Active Storage 0 8 35 Ti 4 1 26 ❑ 26 59 126 - - U3 1 33 ❑ 33 - 127 52 Dressing/Locker/Fitting Room 06 31 113 1 33 ❑ 33 40,616 128 21 Dressing/Locker/Fitting Room 013 13 113 .f 1 33 ❑ 33 33 129 21 Active Storage 0 8 17 Ye -I 1 86 ❑ 86 88 130 48 Dressmg/Locker/Fltting Room 0,8 29 430 ❑ - 2nd FL Sales 32405 Retail - Other Merchandise Sales Area 2 54,810 U 111 430 ❑ 47,730 85,630 2nd FL Sales .- - n _I 8 58 ❑ 464 - 2nd FL Sales - - P J 13 54 ❑ 702 - 2nd FL Sales - _ 4 86 ❑ 344 2nd FL Sales - - CHAN .. 14 600 ❑ 8,400 - 2nd FL Sales - - ri - 18 205 ❑ 3,690 - 2nd FL Sales - - GF .1 648 38 ❑ 24,300 - Golf Service 2488 Retail - Other Merchandise Sales Area 2 4,976 P -J 11 54 ❑ 594 11,506 Golf Service - - Al 'J 62 176 ❑ 10,912 - 225 _ 7 - - U3 '4 1 33 ❑ 33 33 236 162 Active Storage 0 8 130 LG 1 104 ❑ 104 104 229 312 Active Storage 0.8 250 LG =1 2 104 ❑ 208 208 83,198 Worksheet 5b-1 Total Budget 168,894 Wksht 50-1 Total Lighting Power (excluding exempt/track rectums) 88,883 Other Pages Total Number of Additional Worksheet 5b F List the additional worksheets nece- ssary to catalog all luminaires in (t) (m) (n) bulkang Lgttti g Power Budget Space Proposed Bidding Lighting by-Space only (Total of Power (Total of column (k), Area Sgft (not required Worksheet Number column (e)) excluding exempt/track) for Tenant Method) 50-1 158,694 88,883 83,198 542 5,870 8,726 7,326 543 Sum of additional 5b worksheets • Total Bud t of all worksheets 184,584 97,808 90,524 � r r � 11- 5-5 Compliance with OSSC, effective 51151/06 Worksheet 5b-2 Project Name: Dick's Sporting Goods Page. 21 • INTERIOR LIGHTING POWER Space-by-Space Method Only Skip to column (f) if using the Tenant Space Method (a) (b) (C) (d) (a) Lam ID (9) (h) (I) (1 (k) from Quantity of Room ID (do Space Type not leave any Area p Space Lighting Power Worksheet Luminaries (or ' Lu0anaim Lighting Room Y (Table 13-H) Type Budget 5a Column lineal R for track Power Exempt Power Total Ltg ' blanks) (0 (enter space type only once per room) LPD (b) a (d) ( lighting) (Watts) Fixtures (g) x (h) Power Each room 228 272 Aurae Stonsge 0 8 218 10 -1 2 104 ❑ 208 208 mast be 226 137 identified. Active Storage O B 110 LGt 2 54 ❑ 108 108 • DesMbe 218 78 Aceve Storage 0 8 82 LG1 _ 1 2 54 ❑ 108 108 tuminairas for each 223 39 Active Storage 0 8 31 Ti :j. 1 26 ❑ 26 59 Individual room In plans _ '- - U '` {{ 1 33 El - 224 70 Active Storage 0.8 58 71 .i 1 26 ❑ 26 _ 59 4 224 - - U3 '1 1 33 ❑ 33 - 230 1125 Active Storage 0 8 900 LG - 17 104 ❑ 1,768 1.768 For track Ilghtug 231 142 Active Storage 0 8 114 ' '' ' ❑ enter lineal feet in - - column column ( 210 122 Active Storage 0 8 96 LG 1 104 0 104 104 215 93 Active Storage 0 -8 74 A _ 2 79 ❑ 158 158 k Column (l, enter 211 152 Active Storage 0 8 122 A _ 1 5 79 ❑ 395 395 . I 0) 211 70 Stxuts Arena -Ring Spoon Area 2 7 189 T 4 26 ❑ 104 104 . ace at first entry 213 341 Active Storage 0 8 273 LG - 6 104 ❑ 520 520 for the room See 203 122 Restrooms 0 9 110 B 3 79 ❑ 237 237 example In Irseuceoru. 202 128 Res•ooms 0 9 115 B 9 79 ❑ 237 237 234 117 Office-enclosed 1.1 129 A 3 79 ❑ 237 237 235 151 Office-enclosed • 1.1 186 A - 3 79 ❑ 237 237 207 85 Office- enclosed 1 1 105 A - 2 79 O 158 158 205 239 Office-enclosed 11 263 A 1 6 79 ❑ 474 474 233 147 Ofice-ereosed 11 162 A 1 2 79 ❑ 158 158 209 54 Office-enclosed 1 1 92 A -1 2 79 ❑ 158 158 206 63 Office-enclosed 1.1 91 A 2 79 ❑ 158 158 206 134 Ofilce-enclosed 11 147 A 3 79 ❑ 237 237 204 126 Office-enclosed 11 139 A • 4 79 ❑ 318 318 220 132 Electrical/Mechanical 1.5 198 10 _ 2 104 ❑ 208 208 216 1184 Aceve Storage 0 8 931 LG ' -1 8 104 ❑ 832 832 104 177 Stairs - aceve 06 106 F ' 2 54 ❑ 108 108 114 177 Stairs-active 06 106 F 2 54 ❑ 108 108 117 177 Stairs -active 0 6 106 F 2 54 ❑ 108 108 - 212 177 Stags-wen 06 108 F 2 54 ❑ 108 108_ 227 177 Stairs-at-bye 0 6 108 F 2 54 ❑ 108 108 221 177 Stars - aceve 08 108 F 2 54 ❑ 108 108 219 121 - - - ❑ - - - - - 217 56 111 128 StaWareve 08 77 H . • 1 60 ❑ 80 60 109 52 m - - - - ❑ - - 101 423 Codorrrrasidon 0 212 ZI • 8 110 ❑ 660 680 107 32 Actve Storage 0 8 28 F ' 1 54 ❑ 54 51 - 130 48 - - o - 122 21 Dressing/Locker/AWN Room 08 13 U3 _ • 1 33 ❑ 33 33 121 21 Dressing/Locker/Fitting Room 08 13 U 1 33 ❑ 33 33 - - _ ❑ - - - ❑ - - - _ ❑ - - 1 - ❑ - - J _ ❑ 7.326 Worksheet 6b-2 Total Budg et 5.870 Worksheet 5b-2 Total Lighting Power (excluding exempt/track bbl) 6,726 • s r 5 FFr .y �/ 65 Compliance war 0530. efedke 0110158