Loading...
SDR1996-00004 SDR96 - 00004 SEVERSON WAREHOUSE CITY OF TIGARD NOTICE OF DECISION SITE DEVELOPMENT REVIEW SDR 96-0004 SEVERSON WAREHOUSE SECTION I. SUMMARY OF THE REQUEST CASE: FILE NAME: SEVERSON WAREHOUSE Site Development Review SDR 96-0004 PROPOSAL: The applicant requests Site Development Review approval to allow construction of a 12,600 square foot warehouse building. APPLICANT: Jim and Robin Severson OWNER: Same 29404 SW Heater Road Sherwood, OR 97140 ZONING DESIGNATION: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 01BC, Tax Lot 2800). APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120 and 18.164. SECTION II. DECISION Notice is hereby given that the Planning Director for the City of Tigard has APPROVED the above request subject to the following Conditions of Approval. The findings and conclusions on which the decision is based are noted in Section IV. NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 1 Conditions of Approval PRIOR TO THE ISSUANCE OF A BUILDING PERMIT THE FOLLOWING CONDITIONS SHALL BE SATISFIED OR FINANCIALLY SECURED: 1 . The applicant shall provide for roof and pavement rain drainage to the public stormwater drainage system. Staff Contact: Jim Funk, Building Division. 2. Revised site and or landscape plans and permits shall be submitted for review and approval. Staff Contact: Mark Roberts, Planning Division The revisions shall address the following: a. The applicant shall provide a copy of the site plan for review and approval by an authorized franchised hauler for waste and recycling enclosure, design, and location. b. The plan shall be revised to provide street trees at a maximum of 30-feet apart along the private driveway frontage. c. The applicant shall provide a minimum of an additional three trees to serve as shade trees within the parking lot, spaced at a maximum of seven parking spaces apart. d. The plan shall be revised to provide a minimum of a four-foot wide sidewalk beginning at the new parking lot to be constructed and leading to the warehouse entrances. The walkways shall also be extended to the abutting property lines of the vacant industrial sites. For the parcel to the west of the site this may be done by extending the walkway along the front of the new warehouse building to the westerly property line. THE FOLLOWING CONDITIONS SHALL BE SATISFIED PRIOR TO THE ISSUANCE OF OCCUPANCY PERMITS: 3. All site improvements shall be installed and maintained pursuant to the revised site and landscape plans. STAFF CONTACT: Mark Roberts, Associate Planner. THIS APPROVAL IS VALID IF EXERCISED WITHIN EIGHTEEN MONTHS OF THE DATE OF THE FINAL DECISION. SECTION III. BACKGROUND INFORMATION Property History: A Minor Land Partition was filed by U.S. Natural Resources in 1978. Another Site Development Review was filed in 1981 also by U.S. Natural Resources. Two other Minor NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 2 Land Partitions were filed in 1990 by Snyder Roofing and James Severson, along with a Lot Line Adjustment. In 1990 a Site Development Review was filed by James Severson to develop an auto repair, and construction office use. In 1992 a Site Development Review was filed to develop a 1,680 square foot pole building. Vicinity Information: The site is located within a heavily developed industrial area. Adjoining properties are primarily either developed with industrial uses or used for outdoor storage. Site Information and Proposal Description: The site is approximately 1.33 acres. The portion of the property that is to be developed is located to the south and east of an existing developed area on the site. Approximat.3ly 40% of the entire parcel is presently developed. The portion of the site that is proposed to be developed is presently used for materials storage. The site also contains a sea, and/or land container. The entire property slopes slightly towards SW Hunziker Road. The area to be developed does not presently cont, n any vegetation. The applicant proposes to develop a 12,600 square foot warehouse building with associated parking and landscaping. SECTION IV. APPLICABLE REVIEW CRITERIA AND FINDINGS COMPLIANCE WITH THE COMMUNITY DEVELOPMENT CODE: Use Classification: Section 18.70 provides a list of allowed uses within the Light Industrial (I-L) Zoning District. The applicant is proposing additional development of the site with a warehouse use that is allowed as a storage use under the permitted uses for this zoning district. Minimum Lot Area: Section 18.70, the I-L Zoning District provides development standards for new construction. No minimum lot size standard is provided but an average lot width of 50 feet is required. The lot, as presently configured, exceeds an average of 100-feet in width, in complianc: with this standard. Setback and Height: Section 18.70 does not require front, side or rear yard setbacks , except that clear vision areas and parking lot screening requirements must be met. The structure complies with the setback requirements as reviewed elsewhere within this report. The maximum building height is 45 feet in this zoning district for habitable structures. The height of the main building roof line is proposed to be 18-feet, in compliance with the maximum height stand:-1. Landscaping Plan: Section 18.100 requires that the applicant submit a landscape plan that provides landscaping for a minimum of 15% of the site. The I-L Zoning District allows a maximum of 85% of the site to be covered with buildings and NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 3 impervious surfaces. fhe applicant has submitted a plan indicating the type and location of landscaping to be provided. The proposed plan proposes approximately 85% lot coverage with 15% of the site to be developed with landscaping that complies with landscape development standards. Street Trees: Section 18.100.035 states that all development projects fronting on a private driveway, private street or public street shall be required to plant street trees. The plan proposes to provide a total of three "October Glory" Red Maples trees at varying spacing along the proposed private driveway. Because of their 40-foot height at maturity, this species is considered a medium sized specimen at maturity and may be planted at a distance of up to 30-feet apart. The plan shall be revised to provide street trees at a maximum of 30-feet apart along the private driveway frontage. Screening: Special Provisions: Section 18.100.110(A) requires the screening of parking and loading areas. Landscaped parking areas shall include special design features which effectively screen the parking lot areas from view. Planting materials to be installed should achieve a relative balance between low lying and vertical shrubbery and trees. Trees shall also be planted in landscaped islands in all parking areas, and shall be equally distributed on the basis of one tree for each seven parking spaces in order to provide a canopy effect. The preliminary site plan provides a total of four trees to provide shade within the parking lot. Three of these trees are also to serve as street trees. The applicant shall provide a minimum of an additional three trees to serve as shade trees within the parking lot. spaced at a maximum of seven parking spaces apart. Landscape islands require a minimum of three feet of width. Landscaping shall be protected from vehicular damage by some form of wheel guard or curb. The applicant has provided landscape islands that vary between three and 10-feet in width. The site plan provides wheel stops at the end of each parking space in such a manner that the proposed plantings are protected from damage by vehicles using the adjoining parking spaces. Visual Clearance Areas: Section 18.102 requires that a clear vision area be maintained on the corners of all property adjacent to intersecting right-of-ways or the intersection of a public street and a private driveway. A clear vision area shall contain no vehicle, hedge, planting, fence, wall structure obstruction exceeding three feet in height. The code provides that obstructions that may be located in this area shall be visually clear between three and eight feet in height. Trees may be placed within this area provided all branches below eight feet are removed. A visual clearance area is the triangular area formed by measuring a 30 foot distance from the corner of two intersecting street right-of-ways. The clear vision rule also includes triangular areas on either side of proposed driveway(s). For driveways in excess of 24 feet in width such as those proposed to serve this site the clear vision area is measured a 30 foot distance back from the driveway and 30 feet along the adjoining street right-of-way and then connecting these two points. The plan, as proposed, complies with these requirements at the NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 4 intersection of each driveway within the parking lot. These new planting materials do not conflict with the clear vision requirements as shown on the proposed plan. IWnimum Off-Street Parking: Section 18.106 requires a minimum of one off-street parking space for each 1,000 square feet of gross floor area. The applicant has proposed to develop 12,600 square feet of gross floor area therefore a minimum of 13 parking spaces is required. A total of 27 parking spaces are proposed which exceeds the minimum requirement. Section 18.106.050(J)(1) requires that all areas to be used for the parking or storage or maneuvering of a vehicle, boat or trailer shall be improved with an asphalt or concrete surface. The applicant does not propose to pave areas shown to be within the 30-foot access easement along property line. Because an overhead door is proposed on the easterly building elevation, and parking areas would adjoin the unpaved secticn, it is expected that vehicles will use this area. The plan shall be revised to pave a minimum of a 24-foot driveway within this area. In addition, a walkway shall be constructed within this area with a minimum of a four-foot width. The findings for the walkway requirement are discussed elsewhere within this report. The Americans with Disabilities Act (ADA): Revised regulations became effective on January 26, 1992. A minimum of one disabled parking spaces are required if 1- 25 parking spaces are required. The proposed site plan provides two disabled parking spaces near the main entrance. Because the site is only required to provide 13 parking spaces to serve the warehouse, the• two handicapped parking spaces exceed the minimum required parking ratio. Bicycle Parking: Section 18.106 requires one bicycle parking rack for each 15 required parking spaces in any commercial development. Bicycle parkin-: areas shall not be located within :'arking aisles, landscape areas, or pedestrian pathways. Because 13 parking spaces are required, and the plan provides a bicycle rack located around the west side of the proposed office building, the minimum bicycle rack to parking space's ratio has been addressed. The proposed location also complies wit: the minimum standard because it is within 50-feet of the main building entrances. Access: Section 18.108 requires mat where up to 99 parking spaces are required, that one access point with a minimum width of 24 feet of paved width and 30 feet of total width be constructed. The preliminary site plan proposes to develop a driveway to connect to the existing driveway to SW Hunziker Road. A total of 13 parking spaces are required to serve the proposed use. The driveway that provides for shared access to the proposed development site and to adjoining undeveloped pp-eels is expected to have sufficient capacity to serve all four industrial sites if they are developed with similar warehouse uses. However, this driveway may not be sufficient if mostly office uses or other more intensive industrial uses are later proposed for the adjoining parcels. The access that has been proposed is 24-feet in paved width and 30-feet in total v "h, that complies with the minimum dimensional requirements. NOTICE CF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE It is suggested that any _LIlities that are necessary to serve i...ure development on Tax Lot 2700 be extended with this development so as to avoid reconstruction of the paved driveway where possible. Walkways: Section 18.108.050(A) requires that a walkway be extended from the ground floor entrance of all new structures to the street that provides the required ingress and egress. The sidewalk shall be designed to minimize the distance in which pedestrians must cross vehicle access driveways or parking lots. Such crossings shall be designed and located for pedestrian safety and to minimize conflicts. Required walkways shall be physically separated from motor vehicle traffic and parking by either a six inch minimum curbed vertical separation or a minimum three foot horizontal separation. Pedestrian walkways that cross traffic aisles are permitted for distances no greater than 36 feet where appropriate pavement markings, or contrasting pavement materials are used. Walkways shall also be a minimum of four feet in width, exclusive of vehicle overhangs and obstructions such as mailboxes, benches, bicycle racks, and sign posts. The existing use, as designed, precludes the development of a direct walkway to SW Hunziker Road without narrowing the existing width of the access driveway. Narrowing the driveway serving the existing warehouse would be expected to limit the viability of the site for larger trucks that use the existing warehouse. The site plan, as proposed, does not provide walkway linkages to the proposed warehouse or the future development sites. The plan shall be revised to provide a minimum of a four-foot wide sidewalk beginning at the new parking lot to be constructed and leading to the warehouse entrances. The walkways shall also be extended to the abutting property lines of the vacant industrial sites. For the parcel to the west of the site this may be done by extending the walkway along the front of the new warehouse building to the westerly property line. Signs: Section 18.114 lists the type of allowable signs and sign area permitted in the I-L Zoning District. All future proposed signage shall be reviewed and approved through the sign permit process, as administered by the Development Services Technicians. Mixed Solid Waste and Recyclable Storage: Section 18.116 requires that new construction incorporate functional and adequate space for on-site storage and efficient collection of mixed solid waste and source separated recyclable prior to pick-up and removal by the franchised haulers. The site plan provides a trash and recycling enclosure. The applicant shall contact the franchised hauler and have the enclosure design reviewed and approved, in terms of size and design, to ensure ease of site servicing. SECTION V. OTHER STAFF COMMENTS The Engineering Department has reviewed this application and provided the following findings: NOTICE OF DECISION SCR 96-0004-SEVERSON WAREHOUSE PAGE 6 Streets: This site adjoins SW Hunziker Street that is classified as a major collector street. There is 60-feet of total right-of-way adjacent to this site (30-feet south of centerline). The roadway is fully improved on the south side of the street. No additional dedications or street improvements are required. Sanitary Sewer: There is an existing on-site private six-inch sanitary sewer line that is served by the public sanitary sewer line in Hunziker Street. The applicant's plan indicates the new warehouse will be served by the existing on-site sewer line. Storm Drainage: Storm drainage from this site flows generally to the north. The plans indicate the new warehouse will be served from an existing on-site private 10-inch storm line. The City has agreed to enforce Surface Water Management (SWM) regulations established by the Unified Sewerage Agency (USA) (Resolution and Order No. 91-47, as amended by R&O 91-75) which require the construction of on-site water quality facilities. The facilities shall be designed to remove 65 percent of the phosphorus contained in 100 percent of the storm water runoff generated from newly created impervious surfaces. This project wily of increase the impervious surfaces on this site; there will actually be a reduction in impervious surface area. A 2,400 square foot area of compacted gravel storage area will be converted into a landscaped area; in exchange, the building addition will add 1,360 square foot of new impervious area. The net change is a decrease of 1,040 square foot of impervious area. Therefore, ther:, are no water quality requirements. SECTION VI. CIT AND AGENCY COMMENTS The Tualatin Valley Fire District reviewed this application and stated that plans cannot be approved at this time: 1.) Provide details showing the fire department connection (FDC) to an automatic sprinkler system. FDC must be within 70-feet of the fire hydrant and at least 20-feet from the structure. General Telephone and Electronics (GTE) reviewed this application and stated that the developer, and/or owner, shall coordinate conduit requirements with GTE. No other comments have been received. NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 7 SECTION VII. PROCEDURE AND APPEAL INFORMATION Notice: Notice was posted at City Hail and mailed to: X The applicant and owners X Owners of record within the required distance X Affected government agencies Final Decision: THE DECISION SHALL BE FINAL ON APRIL 1, 1996 UNLESS AN APPEAL IS FILED. Appeal: Any party to the decision may appeal this decision in accordance with Section 18.32.290(A) and Section 18.32.370 of the Community Development Code that provides that a written appeal must be filed with the City Recorder within 10 days after notice is given and sent. The appeal fee schedule and forms are available from the Planning Division at Tigard City Hall, 13125 SW Hall Blvd., Tigard, Oregon 97223. The deadline for filing of an appeal is 3:30 p.m. on April 1, 1996. Questions: If you have questions, please call the City of Tigard Planning Department, Tigard City Hall, 13125 SW Hall Boulevard, Tigard, Oregon at (503) 639-4171. //"L- * i �, 3/21/96 PREPARED BY: Mark Roberts DATE Associate Planner '/' ( �` � t t 3/21/96 APPROVED BY: Richard Bewersdorff' DATE Senior Planner ✓ NOTICE OF DECISION SDR 9E-0G04-SEVERSON WAREHOUSE PAGE 8 1---- f"."4:C . I—11 / X r ; , IA —i V `w' •' sue x. I -0. 4 Hi 4 c ..........--g 1>rm ,, ) ---. , ,. -,______, %.,, 0 , I i T 'bj , % ------- .. r—...._,.... .1 I ''Sir i i. /1 , ----- --■ _ .% ift.w. iv , 0 , 4/ 1 :) VI\ 1 2 1 .G.. 'a �1 += C - r !t N \,---- .,..;,,—:"-t,..„,,L._.. ..., I , , , m . . > A i.. o:h........... ............... -7-'7._ rn - ca — - CM N - M -� 1_ n..��� � S.s,.-..7...-/ M]•5' ; Vi• a _ _\. -41', — -e _. - Iti f e.w m • o 0 i► `'o I —I 4 I ', ill L CITY OF TIGARD PLANNING DEPT. :�A CO OW is. ..• PL laj 4(% 9 4P < ANI o 4.V 1"*. 0, ,. , , . I # c co 6')' 4. I E: 9 sus. CT.PAR ,c), `I'd • >N Ma :1-• U Vicinity Map A SDR 96-0004 za SE6FRS0N WAREHOUSE REQUEST FOR COMMENTS RECEIVED PLANNING 1NJ\\3. FEB 211OQ CITY OF TIGARD REQUEST FOR COMMENTS DATE: February 8. 1996 TO: Elaine Self. GTE Engineering Office FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503) 639-4171 Fax: (503)684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 'IBC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY: Tuesday - January 16, 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PLEASE CHECK THE FOLLOWING ITEMS THAT APPLY: We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. Y. Written comments provided below: o G F_l o Q Elf p nl E To 0261 rJ ATE. Co P-46 d Cht_3( fiEnenl s (7 t{ (TE . Please provide theforrowing infonnation) Name of Person(s) Commenting: Ukoz9z-6,..vr Phone Number(s): C_5o3) b2o-�9� SDR 96-0004 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS REL....CD PLANNING FEB 1 5 1996 CITY OF TIGARD REQUEST FOR COMMENTS DATE: February 8, 1996 TO: Lee Walker, Unified Sewerage Agency/SWM Program FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503) 639-4171 Fax: (503) 684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY: Tuesday - January 16, 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PLEASE CHECK THE FOLLOWING ITEMS THAT APPLY: I We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. AWritten comments provided below: L U Caf Y f Ci ( I ( / Qui ; E .1 -`> Gtot,"d 4d 61)``4 S ' (f 0)&asepravitfe the focowinginformation) Name of Person(s) Commenting: L , � j - Phone Number(s): (/ )1(:-) SDR 96-0004 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS RECEIVED PLANNING FER 13 19t3 • AA- CITY OF TIGARD REQUEST FOR COMMENTS DATE: February 8, 1996 TO: David Scott, Building Official FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503) 639-4171 Fax: (503) 684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY: Tuesday - January 16, 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PASE CHECK THE FOLLOWING ITEMS THAT APPLY: I We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. Written comments provided below: O'Cease provide the fa-awing information) Name of Person(s) Commenting: ;144 Phone Number(s): 2 0 SDR 96.0004 SEVERSON WAREHOUSE 6-Feb-96 PROPOSAL/REQUEST FOR COMMENTS Ili RECEIVED PLANK OF TIGARD REQUEST FOR COMMENTS DATE: February 8, 1996 TO: Brian Moore, Portland General Electric FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503) 639-4171 Fax: (503) 684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 SEVERSON WAREHOUSE A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 IBC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY: Tuesday - January 16, 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PLEASE CHECK THE FOLLOWING ITEMS THAT APPLY: ✓� We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. _ Written comments provided below: (Prease provide the fo ng information) Name of Person(s) Commenting:`-� mco,e Phone Number(s): � _ - . SDR%-0001 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS / MUM PLANNING woe \-01 N frA • �JP i • �< �� TUALATIN VALLEY FIRE & RESCUE ` AND J BEAVERTON FIRE DEPARTMENT A.,i4 GJY 4755 S.W. Griffith Drive• P.O. Box 4755 • Beaverton, OR 97076• (503) 526-2469• FAX 526-2538 RES February 19, 1996 Mark Roberts City of Tigard Planning Department 13125 S.W. Hall Blvd. Tigard, Oregon 97223 Re: Severson Warehouse 8250 S.W. Hunziker Street Road File Number: 620-96 Dear Mark: This is a Fire and Life Safety Plan Review and is based on the 1991 editions of the Uniform Fire Code (UFC) and those sections of the Uniform Building Code (UBC) and Uniform Mechanical Code (UMC) specifically referencing the fire department, and other local ordinances and regulations. This plan review shall become a part of the approved plans and attached thereto. Plans cannot be approved at this time. Provide details showing fire department connection (FDC) to automatic sprinkler system. FDC must be within 70 feet of the fire hydrant and at least 20 feet from the structure. Please provide fire flow calculations for fire fighting water supply (attached). If you have questions or need additional information, please contact me at 526-2469 referring to the above noted file number. Sincerely, J L.ien o DFN ans Examiner JLR:kw "Working"Smoke Detectors Save Lives • Tualatin Valley Fit-L. Rescue Rev. 10-5-94 and Beaverton Fire Department 4755 S.W. Griffith Dr. P.O. Box 4755 Beaverton, OR 97076 (503) 526-2469 FAX 526-2538 REQUIRED FIRE FLOW WORK SHEET t TO BE USED WITH FIRE FLOW CALCULATION INSTRUCTIONS Fire Dept Use Only 1) Building Name: FMZ / / 2) Address: City/Co 3) Type of Structure: (Check 1 Box) Date: ❑ I FR, II FR ❑ II One Hour, III One Hour ❑ IV Heavy Timber, V-One Hour ❑ II-N, III-N ❑ V-N 4) Total Building Square Footage: Use the largest aggregate floor area of all floors inclusive of mezzanines as defined by UBC Section 407 floor area. In Types I and II FR construction only, the three largest successive floor areas shall be used. 5) Building Fire Flow (BFF): from UFC Table A-III-A-1. (See Fire Flow Calculation Instruction Handout, Pg. 8) 6)' a Single Occupancy Hazard: (BFF) X (Occupancy Factor) = Required Fire Flow (fill in line 8) b Multiple Occupancy Hazard: Occupancy occ sq ft - bldg sq ft = %BAtt Occupancy occ sq ft = bldg sq ft = %BA Occupancy occ sq ft ± bldg sq ft = %BA Occupancy occ sq ft ± bldg sq ft = %BA 7) Occupancy X Factor: % BA X gpm BFF X (occ fact) = FFttt % BA X gpm BFF X (occ fact) = FF % BA X gpm BFF X (occ fact) = FF % BA X gpm BFF X (occ fact) = FF (Fill in Line 8) TOTAL Required Fire Flow Wotic Sheet Page 2 8) Total Required Fire Flow: 9) Credited Required Fire Flow: (Use only one of lines a, b, or c) a. Multiply Line 8 by 75% for full fire alarm or b. Multiply Line 8 by 50% for automatic sprinkler protection or c. Multiply Line 8 by 25% for central station supervised automatic sprinkler protection 10) Available Fire Flow': t Round off numbers to nearest whole tt Building Area ttt Fire Flow Example: Apartment building with garages Type V-N construction, aggregate square footage 12,000 square feet. Garages 3,500 square feet, apartments 8,500 square feet, BFF = 3,000 gpm. Apartment 8,500 occ sq ft _ 12,000 bldg sq ft = 71% BA Garages 3,500 occ sq ft - 12,000 bldg sq ft = 29% BA 71% (BA) X 3,000 gpm (BFF) X 1.0 (occ fac) = 2,130 gpm 29% (BA) X 3,000 gpm (BFF) X 1.1 (occ fac) = 957 gpm Total Required Fire Flow 3087 gpm The required fire flow of this building is greater than 3,000 gpm, therefore, either area separation walls (see Fire Prevention Ordinance Sec. 22 or Fire Flow Calculation Instructions, Pg. 3 Sec. 4) complying with UBC Sec. 505(f) would need to be installed or one of the automatic sprinkler alternates or central station supervised alarm system (see Fire Prevention Ordinance Sec. 23E or Fire Flow Calculation Instructions, Pg. 7 Sec. 5(e)). One may also upgrade the type of construction. The same applications are true if required fire flow is greater than available fire flow. 1. If single occupancy hazard, place answer on Line 8 . If multiple occupancy hazard, skip to line 6b. When multiple occupancy hazards are housed within a single fire flow area, the building fire flow shall be factored out to the ratios of floor areas housing various occupancies. Each portion of the building fire flow for a given occupancy hazard shall be multiplied by the occupancy factor and then added together to produce a required fire flow. 2 . This information is available from the fire district unless the building is in a newly developed area or new fire mains are to be installed. If the latter is the case, please provide engineered calculations showing estimated flows for the area. Pp,'(IN q< '‘lh TUALATIN VALLEY FIRE & RESCUE AND < - BEAVERTON FIRE DEPARTMENT /N ...\) 4755 S.W. Griffith Drive• P.O. Box 4755 • Beaverton, OR 97076• (503) 526-2469• FAX 526-2538 F&RES FIRE FLOW CALCULATION INSTRUCTIONS To assure that adequate amounts of water (available fire flow) are being provided to a building site, the fire code requires that a fire flow based on type of construction, size of building, and hazard of occupancy be calculated. This is called "required fire flow" . The Fire District has determined that its resources (man power, equipment, etc. , ) can produce an average fire flow of 3 , 000 gallons per minute (gpm) (applicable fire flow) without depleting its resources below minimum standards for other emergency responses. The Fire Prevention Ordinance requires that required fire flow shall not exceed the available fire flow or the 3 , 000 gpm applicable fire flow, which ever is smaller. The following are excerpts from the Uniform Fire Code (1991 Edition) and Tualatin Valley Fire and Rescue Fire Prevention Ordinance 92-01 to help you establish fire flow requirements for your project, and to document those requirements in the fire district records. Included is a work sheet to aid you in computing the required fire flow. Integrated Fire Prevention Ordinance and Uniform Fire Code. A. Rural Water Supply: When an approved municipal type water supply is not available, water supply for fire fighting shall be provided in accordance with National Fire Protection Association (NFPA) Standard 1231, 1989 Edition, Standard on Water Supplies for Suburban and Rural Fire Fighting. Commercial occupancies shall be equipped with a smoke alarm system supervised by a central station which has been approved by the Fire Marshal . The alarm system shall be installed in accordance with Uniform Fire Code Standards 14-1 and 14-2 . EXCEPTIONS: 1 . When smoke detection would produce adverse or false alarms, upon judgement of the Fire Marshal , fixed temperature/rate of rise heat detection may be substituted . "Working"Smoke Detectors Save Lives 2 . In other than the occupancies listed in ORS 479 . 010 (1) i, where in the opinion of the Fire Marshal the loss of a structure would not incur substantial impact on the community financially, the fire flow may be waived provided the building does not exceed a 1, 000 gpm required fire flow, is a light hazard occupancy, and has a smoke detection system installed throughout complying with Uniform Fire Code Standard 14-1 and 14-2 that is monitored by a central station which has been approved by the Fire Marshal. 3 . When there are not more than two Group R-3 or Group M structures per acre, the requirements of this section may be modified provided, in the opinion of the Chief, fire fighting or rescue operations would not be impaired. B. Water Supply: An approved water supply for areas inside water districts or municipally developed water supplies capable of supplying required fire flow for fire protection shall be provided to all premises upon which buildings are moved to or buildings or portions of buildings are hereafter constructed. EXCEPTIONS: Exceptions #2 and #3 of A above may be applied to B. C. Required Fire Flow: No building shall be constructed, altered, enlarged or repaired in a manner that by reason of size, type of construction, number of stories, occupancy, or any combination thereof creates a need for a fire flow in excess of 3 , 000 gpm at 20 pounds per square inch (psi) residual pressure, or exceeds the available fire flow at the site of the structure. The requirements for determining fire flow for all buildings are set out in Uniform Fire Code Appendix III-A, in areas with municipally developed water supplies or, in NFPA 1231 for rural areas where no municipally developed water supply is available. 1 . Fire flow requirements in excess of 3 , 000 gpm may be allowed if, in the opinion of the Chief, all reasonable methods of reducing the fire flow have been included within the development and no unusual hazard to life and property exists. 2 . Existing buildings that require a fire flow in excess of 3 , 000 gpm are not required to comply with the fire flow requirements of this section. However, alterations, additions, or repairs shall not further increase the required fire flow for the buildings. -2- Division III • FIRE PROTECTION APPENDIX III-A FIRE-FLOW REQUIREMENTS FOR BUILDINGS 1. SCOPE The procedure determining fire-flow requirements for buildings or portions of buldings hereafter constructed shall be in accordance with this appendix. This appendix does not apply to structures other than buildings. 2 . DEFINITIONS For the purpose of this appendix, certain terms are defined as follows: FIRE AREA is the floor area, in square feet, used to determine the required fire flow. FIRE FLOW is the flow rate of water supply, mesured at 20 psi residual pressure, that is available for fire fighting. 3 . MODIFICATIONS (a) Decreases. Fire flow requirements may be modified downward by the chief for isolated buildings or a group of buildings in rural areas or small communities where the development of full fire-flow requirements is impractical. (b) Fire flow may be modified upward by the chief where conditions indicate an unusual susceptibity to group fires or conflagrations. An upward modification shall not be more than twice that required for the buiding under consideration. 4 . FIRE AREA (a) General. The fire area shall be the total floor area of all floor levels within the exterior walls, and under the horizontal projections of the roof of a building, except as modified in this section. (b) "Each portion of a building separated by one or more area separation wall (s) , in accordance with the Uniform Building Code, Section 505 (f) , may be considered as a separate fire area(s) for the purpose of determining required fire flow. " (c) Type I and Type II-F.R. Construction. The fire area of buildings constructed of Type I and Type II-F.R. construction shall be the area of the three largest successive floors. 5. Fire-Flow Requirements for Buildings. (a) The minimum fire flow requirements for one and two- family dwellings shall be 1, 000 gpm. EXCEPTION: Fire flow may be reduced by 50 percent when the building is provided with an approved automatic fire extinguishing system. -3- (b) The required fire flow for buildings other than one and two-family dwellings shall be determined by the size, construction, and occupancy hazard of the building being considered as designated by Table A-III-A-1 (see end of hand out) and multiplied by the following occupancy factors: Light Hazard Occupancies 1. 00 Ordinary Hazard (Group 1) 1. 10 Ordinary Hazard (Group 2) 1.20 Ordinary Hazard (Group 3) 1.30 Extra Hazard (Group 1) 1.40 Extra Hazard (Group 2) 1.50 (Fire Flow = Occupancy Factor X Table A-III-A-1) Occupancy examples in the listings as shown in the various hazard classifications are intended to represent the norm for those occupancy types. Unusual or abnormal fuel loadings or combustible characteristics and susceptibility for changes in these characteristics, for a particular occupancy, are considerations that should be weighed in the selection and classification. EXAMPLES OF HAZARD CLASSIFICATIONS: Light Hazard. Occupancies or portions of other occupancies where the quantity and/or combustibility of contents is low and fires with relatively low rates of heat release are expected. Light Hazard Occupancies include occupancies having conditions similar to: Churches Clubs Eaves and overhangs, if combustible construction with no combustibles beneath. Educational Hospitals Institutional Libraries, except large stack rooms Museums Nursing or Convalescent Homes Office, including Data Processing Residential Restaurant seating areas Theaters and Auditoriums excluding stages and prosceniums Unused attics Ordinary Hazard (Group 1) . Occupancies or portions of other occupancies where combustibility is low, quantity of combustibles is moderate, stock piles of combustibles do not exceed 8 ft (2 . 4m) and fires with moderate rates of heat release are expected. -4- Ordinary Hazard Occupancies (Group 1) include occupancies having conditions similar to: Automobile parking garages Bakeries Beverage manufacturing Canneries Dairy products manufacturing and processing Electronic plants Glass and glass products manufacturing Laundries Restaurant service areas Ordinary Hazard (Group 2) . Occupancies or portions of other occupancies where quantity and combustibility of contents is moderate, stock piles do not exceed 12 ft (3.7m) and fires with moderate rate of heat release are expected. Ordinary Hazard Occupancies (Group 2) include occupancies having conditions similar to: Cereal mills Chemical Plants - Ordinary Cold storage warehouses Confectionery products Distilleries Leather goods manufacturing Libraries-large stack room areas Machine shops Metal working Mercantiles Printing and publishing Textile manufacturing Tobacco products manufacturing Wood product assembly Ordinary Hazard (Group 3) . Occupancies or portions of other occupancies where quantity and/or combustibility of contents is high, and fires of high rate of heat release are expected. Ordinary Hazard Occupancies (Group 3) include occupancies having conditions similar to: Feed mills Paper and pulp mills Paper process plants Piers and wharves Repair garages Tire manufacturing Warehouses (having moderate to higher combustibility of content, such as paper, household furniture, paint, general storage, whiskey, etc. ) Wood machining -5- Extra Hazard Occupancies. Extra hazard occupancies or portions of other occupancies where quantity and combustibility of contents is very high, and flammable and combustible liquids, dust, lint or other materials are present introducing the probability of rapidly developing fires with high rates of heat release. Extra hazard occupancies involve a wide range of variables which may produce severe fires. The following shall be used to evaluate the severity of extra hazard occupancies. Extra Hazard (Group 1) include occupancies described in above for Extra Hazard with little or no flammable or combustible liquids. Extra Hazard Occupancies (Group 1) include occupancies having conditions similar to: Combustible Hydraulic Fluid use areas Die Casting Metal Extruding Plywood and particle board manufacturing Printing (using inks with below 100° F[37 . 8°C] flash points) Rubber reclaiming, compounding, drying, milling, vulcanizing Saw mills Textile picking, opening, blending, garnetting, carding, combining of cotton, synthetics, wood shoddy or burlap Upholstering with plastic foams Extra Hazard (Group 2) include occupancies described in above for Extra Hazard with moderate to substantial amounts of flammable or combustible liquids or where shielding of combustibles is extensive. Extra Hazard Occupancies (Group 2) include occupancies having conditions similar to: Asphalt saturating Flammable liquids spraying Flow coating Mobile Home or modular building assemblies (where finished enclosure is present and has combustible interiors) Open Oil quenching Solvent cleaning Varnish and paint dipping (c) The product of the above multiplication gives the required flow. (d) In types I and II F.R. construction, only the three largest successive floor areas shall be used. -6- (e) The required fire flow may be reduced by one of the • following options, but in no case to less than 1, 000 gpm at 20 psi residual: (1) 75 percent where a complete approved automatic fire extinguishing system meeting the requirements of the Uniform Building Code, Chapter 38, is installed throughout the building and the system is fully and electrically supervised in accordance with Uniform Fire Code Standard 14-1 and is monitored by an approved central station meeting the requirements of NFPA Standard No. 71, 1989 Edition. (2) 50 percent where a complete automatic fire extinguishing system meeting the requirements of the Uniform Building Code, Chapter 38, is installed throughout the building. (3) 25 percent where an approved complete smoke sensing fire detection and manual fire alarm system is installed throughout the building and electrically interconnected one with the other and electrically intertied to an approved central receiving station. The smoke detection shall meet the requirements of Uniform Fire Code Standard 14-2, and manual fire alarm pull system shall meet the requirements of Uniform Fire Code Standard 14-1. -7- TABLE NO. A-III-A-1 MINIMUM REQUIRED FIRE FLOW AND FLOW DURATION FOR BUILDINGS FIRE FLOW Type Type Type Type (gallons FLOW I-F.R. II One-HR IV-H.T. II-N Type per DURATION II-F.R.' III One-HR' V-One-HR' III-N' V-N' minute) (hours) 22, 700 12,700 8,200 5,900 3,600 1,500 30,200 17,000 10,900 7,900 4,800 1,750 38,700 21,800 12,900 9,800 6,200 2,000 2 48,300 24,200 17,400 12,600 7,700 2,250 59,000 33,200 21,300 15,400 9,400 2,500 70,900 39,700 25,500 18,400 11,300 2,750 83,700 47,100 30,100 21,800 13,400 3,000 97,700 54,900 35,200 25,900 15,600 3,250 3 112,700 63,400 40,600 29,300 18,000 3,500 128,700 72,400 46,400 33,500 20,600 3,750 145,900 82, 100 52,500 37,900 23,300 4,000 164,200 92,400 59,100 42,700 26,300 4,250 183,400 103, 100 66,000 47,700 29,300 4,500 203,700 114,600 73,300 53,000 32,600 4, 750 225,200 126, 700 81, 100 58,600 36,000 5,000 247,700 139,400 89,200 65,400 39,600 5,250 271,200 152,600 97,700 70,600 43,400 5,500 4 295,900 166,500 106,500 77,000 47,400 5,750 Greater Greater 115,800 83,700 51,500 6,000 125,500 90,600 55,700 6,250 135,500 97,900 60,200 6,500 " 145,800 106,800 64,800 6,750 " 156,700 113,200 69,600 7,000 " 167,900 121,300 74,600 7,250 " 179,400 129,600 79,800 7,500 " " 191,400 138,300 85, 100 7,750 ll I Greater Greater Greater 8,000 II -8- MEMORANDUM CITY OF TIGARD, OREGON DATE: March 19, 1996 TO: Mark Roberts Q� FROM: Brian Rager, Development Review Engineer RE: SDR 96-0004 SEVERSON WAREHOUSE Description: The applicant requests Site Development Review approval to allow the construction of a 12,600 square foot(sf) warehouse building to be located at 8250 SW Hunziker Street. The site is situated south of and adjacent to SW Hunziker Street, north of SW Burnham Street, east of SW Hall Blvd., and west of SW Wall Street. The subject site consists of Tax Lot 2800 (2S1 1BC)with an area of 1.36 acres. Findings: 1. Streets: This site lies adjacent to SW Hunziker Street which is classified as a major collector street. There is 60 feet of total right-of-way adjacent to this site (30 feet south of centerline). The roadway is fully improved on the south side of the street. No further dedications or street improvements are required. 2. Sanitary Sewer: There is an existing op-site private 6-inch sanitary sewer line that is served by the public sanitary sewer line in Hunziker Street. The applicant's plan indicates the new warehouse will be served by the existing on-site sewer line. 3. Storm Drainage: Storm drainage from this site flows generally to the north. The plans indicate the new warehouse will be served from an existing on-site private 10-inch storm line. The City has agreed to enforce Surface Water Management (SWM)regulations established by the Unified Sewerage Agency (USA) (Resolution and Order No. 91-47, as amended by R&O 91-75)which require the construction of on-site water quality facilities. The facilities shall be designed to remove 65 percent of ENGINEERING COMMENTS SDR 96-04 Severson Warehouse PAGE 1 the phosphorus contained in 100 percent of the storm water runoff generated from newly created impervious surfaces. This project will not increase the impervious surfaces on this site; there will actually be a reduction in impervious surface area. A 2,400 sf area of compacted gravel storage area will be converted into a landscaped area; in exchange,the building addition will add 1,360 sf of new impervious area. The net change is a decrease of 1,040 sf of impervious area. Therefore, there are no water quality requirements. Recommendations: THE FOLLOWING CONDITIONS SHALL BE SATISFIED PRIOR TO ISSUANCE OF THE BUILDING PERMIT: 1. The applicant shall provide for roof and pavement rain drainage to the public stormwater drainage system. APPROVED: fru Gary' Alfson, A ting City Engineer i:\eng\brianr\sdr96-04.bdr ENGINEERING COMMENTS SDR 96-04 Severson Warehouse PAGE 2 t ive) PLANNING FEB 12 1996 . 411- Is CITY OF TIGARD REQUEST FOR COMMENTS DATE: February 8, 1996 TO: Kelley Jennings, Tigard Police Dept. Crime Prevention Officer FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503)639-4171 Fax: (503) 684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE Q A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY: Tuesday - January 16. 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PLEASE CHECK THE FOLLOWING ITEMS THAT APPLY: We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. _ Written comments provided below: (Please provide the fo(&wing information) Name of Person(s) Comme g• 41,4, Phone Number(s): N Z 1 SDR 96-0004 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS 'I S,�1 CITY OF TIGARD REQUEST FOR COMMENTS DATE: February 8, 1996 TO: Per Attached FROM: City of Tigard Planning Department STAFF CONTACT: Mark Roberts (x317) Phone: (503)639-4171 Fax: (503) 684-7297 RE: SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE A request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Attached is the Site Plan, Vicinity Map and Applicant's Statement for your review. From information supplied by various departments and agencies and from other information available to our staff, a report and recommendation will be prepared and a decision will be rendered on the proposal in the near future. If you wish to comment on this application, WE NEED YOUR COMMENTS BACK BY Tuesday - January 16, 1996. You may use the space provided below or attach a separate letter to return your comments. If you are unable to respond by the above date, please phone the staff contact noted above with your comments and confirm your comments in writing as soon as possible. If you have any questions, contact the Tigard Planning Department, 13125 SW Hall Boulevard, Tigard, OR 97223. PLEASE CHECK THE FOLLOWING ITEMS THAT APPLY: We have reviewed the proposal and have no objections to it. Please contact of our office. Please refer to the enclosed letter. Written comments provided below: (P&ase pm/de the farming information) Name of Person(s) Commenting: Phone Number(s): SDR 96-0004 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS 0 sne q - 000 II . REQUEST FOR COMMENTS I NOTIFICATION LIST FOR LAND USE&DEVELOPMENT APPLICATIONS ICITIZEN INVOLVEMENT TEAMS (circle one) _CIT Area: (W) (S) (E) IC) ® Placed for review in Library CIT Book LH CITY DEPARTMENTS 1411/G.DEPT./David Scott,eurampomad 1,40LICE DEPT./Kelley Jennings,ai,ne nevennanoir e, V OPERATIONS/John Acker,Moo t.Spvst. CITY ADMIN./Cathy Wheatley,nr Recorder ✓LNG.DEPT./Brian Roger,OerelopmenlRo.iewEngneel _COM.DEV.DEPT./D.S.T.'S ADV.PLNG./Nadine Smith, n..ngsen..r. WATER DEPT./Michael Miller,opcaRorn Mpuovinaloru/daiso. SPECIAL DISTRICTS I FIRE MARSHALL _UNIFIED SEWERAGE AGENCY _TUALATIN VALLEY WATER DIST. Gene Birchell SWM Program/Lee Walker PO Box 745 Wa.County Fire District 155 N.First Street Beaverton,OR 97075 (pick-up box) Hillsboro,OR 97124 1 I ArrecI'ED JURISDICTIONS WA.CO.DEPT.OF LAND USE&TRANSP. _METRO AREA BOUNDARY COMMISSION _METRO-GREENSPACES 150 N.First Avenue 800 NE Oregon St.#16,Suite 540 Mel Huie (CPA's/ZOA's) Hillsboro,OR 97124 Portland,OR 97232-2109 600 NE Grand Avenue Portland,OR 97232-2736 _Brent Curtis(CPA's) _STATE HIGHWAY DIVISION _Jim Tice(IGA'S) Sam Hunaidi _ODOT/REGION 1 i =Mike Borreson(Engineer)Scott King(CPA's) PO Box 25412 Laurie Nicholson/Trans.Planning Portland.OR 97225-0412 123 N.W.Flanders 3 _Tom Harry(Current Planning App's) Portland,OR 97209-4037 _Lynn Bailey(Current Planning App's) _OREGON DLCD(CPA's/ZOA's) 1 1175 Court Street,N.E. _ODOT/REGION 1,DISTRICT 2-A _CITY OF BEAVERTON Salem,OR 97310-0590 Bob Schmidt/Engineering Coord. Larry Conrad,Senior Planner 2131 SW Scholls/PO Box 25412 PO Box 4755 _CITY OF PORTLAND Portland,OR 97225 I Beaverton,OR 97076 Planning Director — 1 120 SW 5th OTHER II! _CITY OF KING CITY Portland,OR 97204 ( City Manager _CITY OF LAKE OSWEGO 15300 SW 116th _CITY OF DURHAM City Manager King City,OR 97224 City Manager PO Box 369 PO Box 23483 Lake Oswego,OR 97034 CITY OF TUALATIN Tigard,OR 97281-3483 PO Box 369 Tualatin,OR 97062 - I - SPECIAL AGENCIES GENERAL TELEPHONE ELECTRIC PORTLAND GENERAL ELECTRIC _COLUMBIA CABLE CO. i Elaine Self,Engineering Brian Moore Craig Eyestone PO Box 23416 1 4655 SW Old Scholls Ferry Rd. 1 4200 SW Brigadoon Court Tigard,OR 97281-3416 Beaverton,OR 97007 Beaverton,OR 97005 ✓NTiW NATURAL GAS CO. Phone:(SW)ni-:44+ _METRO AREA COMMUNICATIONS _TRI-MET TRANSIT DEVELOPMENT Scott Palmer Fax:003)721-2S02 Jason Hewitt Kim Knox,Project Planner 220 NW Second Avenue Twin Oaks Technology Center 710 NE Holladay Street Portland,OR 97209-3991 1815 NW 169th Place S-6020 Portland,OR 97232 Beaverton,OR 97006-4886 TCI CABLEVISION OF OREGON _US WEST COMMUNICATIONS _SOUTHERN PACIFIC TRANS.CO. Linda Peterson Pete Nelson Duane M.Forney,PLS-Project Eng. 3500 SW Bond Street 421 SW Oak Street 800 NW 6th Ave.,Room 324 Portland,OR 97201 Portland,OR 97204 Union Station Portland,OR 97209 STATE`AGENCIES FEDERAL AGENCIES _AERONAUTICS DIVISION(ODOT) _DIVISION OF STATE LANDS _US POSTAL SERVICE _COMMERCE DEPT.-M.H.PARK _FISH L WILDLIFE Randy Hammock,Growth Cord. _PUC _DOGAMI Cedar Mill Station DEPT.OF ENVIRONMENTAL QUALITY Portland,OR 97229-9998 i _OTHER _U.S.ARMY CORPS.OF ENGINEERS Ih:\bgn\GOM\rno,t n\rtcnobc.ms, City of Tigard,Oregon AFFIDAVIT OF MAILING STATE OF OREGON ) County of Washington )ss. City of Tigard ) I, Patricia L. Lunsford, being first duly sworn/affirm, on oath depose and say: that I am an Administrative Specialist II for The City of Tigard, Oregon. O That I served NOTICE OF (AMENDED ❑) PUBLIC HEARING FOR: {Check box above,if applicable) {check appropriate box below) (Enter Public Hearing Date above) City of Tigard Planning Director Tigard Planning Commission Tigard Hearings Officer Tigard City Council That I served NOTICE OF (AMENDED ❑) DECISION FOR: (Cheek box above,if applicable} City of Tigard Planning Director ❑ That I served NOTICE OF (AMENDED 0) FINAL ORDER FOR: (Check box above,if applicable) (check appropriate box below) ❑ City of Tigard Planning Director ❑ Tigard Planning Commission Li Tigard Hearings Officer O Tigard City Council • That I served OTHER NOTICE OF FOR: A copy of the PUBLIC HEARING NOTICE/NOTICE OF DECISION/NOTICE OF FINAL ORDER/OTHER NOTICE(S) of whi • . attached, marked Exhibit "A", was mailed to each named p;rson(s) at the address(s) shown on the attached Ii- (s), marked Exhibit"B" o the . SW d of Iii i ;/ 199 , and deposited in the Uni -d States M-il on „ d.y of //. i ,'i 199 , postage prepaid. 4&4 - A.,-� Pr- - red Notice �� '4 - r Subscribed and sworn/affirmed before me on the /7 day of : . , 19 ��+�., OFFICIAL SEAL �� :��.-r DIANE M JELDERKS ,,,_v , ijk__, NOTARY PUBLIC-OREGON �,:;� COMMISSION NO.046142 NO RY PUBLICI OREGO MY COMMISSION EXPIRES SEPTEMBER 07,1999 , My Commission • •Tres: :%17 FILE INFO.: ai�i � NAME(S): t/`vr . CASE NO.(S): ,']� q - 4 TYPE OF NOTICE&/'DATE: £XHIPIT A CITY OF TIGARD NOTICE OF DECISION SITE DEVELOPMENT REVIEW SDR 96-0004 SEVERSON WAREHOUSE SECTION I. SUMMARY OF THE REQUEST CASE: FILE NAME: SEVERSON WAREHOUSE Site Development Review SDR 96-0004 PROPOSAL: The applicant requests Site Development Review approval to allow construction of a 12,600 square foot warehouse building. APPLICANT: Jim and Robin Severson OWNER: Same 29404 SW Heater Road Sherwood, OR 97140 ZONING DESIGNATION: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 01 BC, Tax Lot 2800). APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120 and 18.164. SECTION II. DECISION Notice is hereby given that the Planning Director for the City of Tigard has APPROVED the above request subject to the following Conditions of Approval. The findings and conclusions on which the decision is based are noted in Section IV. NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 1 Conditions of Approval PRIOR TO THE ISSUANCE OF A BUILDING PERMIT THE FOLLOWING CONDITIONS SHALL BE SATISFIED OR FINANCIALLY SECURED: 1. The applicant shall provide for roof and pavement rain drainage to the public stormwater drainage system. Staff Contact: Jim Funk, Building Division. 2. Revised site and or landscape plans and permits shall be submitted for review and approval. Staff Contact: Mark Roberts, Planning Division The revisions shall address the following: a. The applicant shall provide a copy of the site plan for review and approval by an authorized franchised hauler for waste and recycling enclosure, design, and location. b. The plan shall be revised to provide street trees at a maximum of 30-feet apart along the private driveway frontage. c. The applicant shall provide a minimum of an additional three trees to serve as shade trees within the parking lot, spaced at a maximum of seven parking spaces apart. d. The plan shall be revised to provide a minimum of a four-foot wide sidewalk beginning at the new parking lot to be constructed and leading to the warehouse entrances. The walkways shall also be extended to the abutting property lines of the vacant industrial sites. For the parcel to the west of the site this may be done by extending the walkway along the front of the new warehouse building to the westerly property line. THE FOLLOWING CONDITIONS SHALL BE SATISFIED PRIOR TO THE ISSUANCE OF OCCUPANCY PERMITS: 3. All site improvements shall be installed and maintained pursuant to the revised site and landscape plans. STAFF CONTACT: Mark Roberts, Associate Planner. THIS APPROVAL IS VALID IF EXERCISED WITHIN EIGHTEEN MONTHS OF THE DATE OF THE FINAL DECISION. SECTION III. BACKGROUND INFORMATION Property History: A Minor Land Partition was filed by U.S. Natural Resources in 1978. Another Site Development Review was filed in 1981 also by U.S. Natural Resources. Two other Minor NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 2 Land Partitions were filed in 1990 by Snyder Roofing and James Severson, along with a Lot Line Adjustment. In 1990 a Site Development Review was filed by James Severson to develop an auto repair, and construction office use. In 1992 a Site Development Review was filed to develop a 1,680 square foot pole building. Vicinity Information: The site is located within a heavily developed industrial area. Adjoining properties are primarily either developed with industrial uses or used for outdoor storage. Site Information and Proposal Description: The site is approximately 1.33 acres. The portion of the property that is to be developed is located to the south and east of an existing developed area on the site. Approximately 40% of the entire parcel is presently developed. The portion of the site that is proposed to be developed is presently used for materials storage. The site also contains a sea, and/or land container. The entire property slopes slightly towards SW Hunziker Road. The area to be developed does not presently contain any vegetation. The applicant proposes to develop a 12,600 square foot warehouse building with associated parking and landscaping. SECTION IV. APPLICABLE REVIEW CRITERIA AND FINDINGS COMPLIANCE WITH THE COMMUNITY DEVELOPMENT CODE: Use Classification: Section 18.70 provides a list of allowed uses within the Light Industrial (I-L) Zoning District. The applicant is proposing additional development of the site with a warehouse use that is allowed as a storage use under the permitted uses for this zoning district. Minimum Lot Area: Section 18.70, the I-L Zoning District provides development standards for new construction. No minimum lot size standard is provided but an average lot width of 50 feet is required. The lot, as presently configured, exceeds an average of 100-feet in width, in compliance with this standard. Setback and Height: Section 18.70 does not require front, side or rear yard setbacks , except that clear vision areas and parking lot screening requirements must be met. The structure complies with the setback requirements as reviewed elsewhere within this report. The maximum building height is 45 feet in this zoning district for habitable structures. The height of the main building roof line is proposed to be 18-feet, in compliance with the maximum height standard. Landscaping Plan: Section 18.100 requires that the applicant submit a landscape plan that provides landscaping for a minimum of 15% of the site. The I-L Zoning District allows a maximum of 85% of the site to be covered with buildings and NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 3 impervious surfaces. The applicant has submitted a plan indicating the type and location of landscaping to be provided. The proposed plan proposes approximately 85% lot coverage with 15% of the site to be developed with landscaping that complies with landscape development standards. Street Trees: Section 18.100.035 states that all development projects fronting on a private driveway, private street or public street shall be required to plant street trees. The plan proposes to provide a total of three "October Glory" Red Maples trees at varying spacing along the proposed private driveway. Because of their 40-foot height at maturity, this species is considered a medium sized specimen at maturity and may be planted at a distance of up to 30-feet apart. The plan shall be revised to provide street trees at a maximum of 30-feet apart along the private driveway frontage. Screening: Special Provisions: Section 18.100.110(A) requires the screening of parking and loading areas. Landscaped parking areas shall include special design features which effectively screen the parking lot areas from view. Planting materials to be installed should achieve a relative balance between low lying and vertical shrubbery and trees. Trees shall also be planted in landscaped islands in all parking areas, and shall be equally distributed on the basis of one tree for each seven parking spaces in order to provide a canopy effect. The preliminary site plan provides a total of four trees to provide shade within the parking lot. Three of these trees are also to serve as street trees. The applicant shall provide a minimum of an additional three trees to serve as shade trees within the parking lot, spaced at a maximum of seven parking spaces apart. Landscape islands require a minimum of three feet of width. Landscaping shall be protected from vehicular damage by some form of wheel guard or curb. The applicant has provided landscape islands that vary between three and 10-feet in width. The site plan provides wheel stops at the end of each parking space in such a manner that the proposed plantings are protected from damage by vehicles using the adjoining parking spaces. Visual Clearance Areas: Section 18.102 requires that a clear vision area be maintained on the corners of all property adjacent to intersecting right-of-ways or the intersection of a public street and a private driveway. A clear vision area shall contain no vehicle, hedge, planting, fence, wall structure obstruction exceeding three feet in height. The code provides that obstructions that may be located in this area shall be visually clear between three and eight feet in height. Trees may be placed within this area provided all branches below eight feet are removed. A visual clearance area is the triangular area formed by measuring a 30 foot distance from the corner of two intersecting street right-of-ways. The clear vision rule also includes triangular areas on either side of proposed driveway(s). For driveways in excess of 24 feet in width such as those proposed to serve this site the clear vision area is measured a 30 foot distance back from the driveway and 30 feet along the adjoining street right-of-way and then connecting these two points. The plan, as proposed, complies with these requirements at the NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 4 intersection of each driveway within the parking lot. These new planting materials do not conflict with the clear vision requirements as shown on the proposed plan. Minimum Off-Street Parking: Section 18.106 requires a minimum of one off-street parking space for each 1,000 square feet of gross floor area. The applicant has proposed to develop 12,600 square feet of gross floor area therefore a minimum of 13 parking spaces is required. A total of 27 parking spaces are proposed which exceeds the minimum requirement. Section 18.106.050(J)(1) requires that all areas to be used for the parking or storage or maneuvering of a vehicle, boat or trailer shall be improved with an asphalt or concrete surface. The applicant does not propose to pave areas shown to be within the 30-foot access easement along property line. Because an overhead door is proposed on the easterly building elevation, and parking areas would adjoin the unpaved section, it is expected that vehicles will use this area. The plan shall be revised to pave a minimum of a 24-foot driveway within this area. In addition, a walkway shall be constructed within this area with a minimum of a four-foot width. The findings for the walkway requirement are discussed elsewhere within this report. The Americans with Disabilities Act (ADA): Revised regulations became effective on January 26, 1992. A minimum of one disabled parking spaces are required if 1- 25 parking spaces are required. The proposed site plan provides two disabled parking spaces near the main entrance. Because the site is only required to provide 13 parking spaces to serve the warehouse, the two handicapped parking spaces exceed the minimum required parking ratio. Bicycle Parking: Section 18.106 requires one bicycle parking rack for each 15 required parking spaces in any commercial development. Bicycle parking areas shall not be located within parking aisles, landscape areas, or pedestrian pathways. Because 13 parking spaces are required, and the plan provides a bicycle rack located around the west side of the proposed office building, the minimum bicycle rack to parking space's ratio has been addressed. The proposed location also complies with the minimum standard because it is within 50-feet of the main building entrances. Access: Section 18.108 requires that where up to 99 parking spaces are required, that one access point with a minimum width of 24 feet of paved width and 30 feet of total width be constructed. The preliminary site plan proposes to develop a driveway to connect to the existing driveway to SW Hunziker Road. A total of 13 parking spaces are required to serve the proposed use. The driveway that provides for shared access to the proposed development site and to adjoining undeveloped parcels is expected to have sufficient capacity to serve all four industrial sites if they are developed with similar warehouse uses. However, this driveway may not be sufficient if mostly office uses or other more intensive industrial uses are later proposed for the adjoining parcels. The access that has been proposed is 24-feet in paved width and 30-feet in total width, that complies with the minimum dimensional requirements. NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 5 It is suggested that any utilities that are necessary to serve future development on Tax Lot 2700 be extended with this development so as to avoid reconstruction of the paved • driveway where possible. Walkways: Section 18.108.050(A) requires that a walkway be extended from the ground floor entrance of all new structures to the street that provides the required ingress and egress. The sidewalk shall be designed to minimize the distance in which pedestrians must cross vehicle access driveways or parking lots. Such crossings shall be designed and located for pedestrian safety and to minimize conflicts. Required walkways shall be physically separated from motor vehicle traffic and parking by either a six inch minimum curbed vertical separation or a minimum three foot horizontal separation. Pedestrian walkways that cross traffic aisles are permitted for distances no greater than 36 feet where appropriate pavement markings, or contrasting pavement materials are used. Walkways shall also be a minimum of four feet in width, exclusive of vehicle overhangs and obstructions such as mailboxes, benches, bicycle racks, and sign posts. The existing use, as designed, precludes the development of a direct walkway to SW Hunziker Road without narrowing the existing width of the access driveway. Narrowing the driveway serving the existing warehouse would be expected to limit the viability of the site for larger trucks that use the existing warehouse. The site plan, as proposed, does not provide walkway linkages to the proposed warehouse or the future development sites. The plan shall be revised to provide a minimum of a four-foot wide sidewalk beginning at the new parking lot to be constructed and leading to the warehouse entrances. The walkways shall also be extended to the abutting property lines of the vacant industrial sites. For the parcel to the west of the site this may be done by extending the walkway along the front of the new warehouse building to the westerly property line. Signs: Section 18.114 lists the type of allowable signs and sign area permitted in the I-L Zoning District. All future proposed signage shall be reviewed and approved through the sign permit process, as administered by the Development Services Technicians. Mixed Solid Waste and Recyclable Storage: Section 18.116 requires that new construction incorporate functional and adequate space for on-site storage and efficient collection of mixed solid waste and source separated recyclable prior to pick-up and removal by the franchised haulers. The site plan provides a trash and recycling enclosure. The applicant shall contact the franchised hauler and have the enclosure design reviewed and approved, in terms of size and design, to ensure ease of site servicing. SECTION V. OTHER STAFF COMMENTS The Engineering Department has reviewed this application and provided the following findings: NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 6 Streets: This site adjoins SW Hunziker Street that is classified as a major collector street. There is 60-feet of total right-of-way adjacent to this site (30-feet south of centerline). The roadway is fully improved on the south side of the street. No additional dedications or street improvements are required. Sanitary Sewer_ There is an existing on-site private six-inch sanitary sewer line that is served by the public sanitary sewer line in Hunziker Street. The applicant's plan indicates the new warehouse will be served by the existing on-site sewer line. Storm Drainage: Storm drainage from this site flows generally to the north. The plans indicate the new warehouse will be served from an existing on-site private 10-inch storm line. The City has agreed to enforce Surface Water Management (SWM) regulations established by the Unified Sewerage Agency (USA) (Resolution and Order No. 91-47, as amended by R&O 91-75) which require the construction of on-site water quality facilities. The facilities shall be designed to remove 65 percent of the phosphorus contained in 100 percent of the storm water runoff generated from newly created impervious surfaces. This project will not increase the impervious surfaces on this site; there will actually be a reduction in impervious surface area. A 2,400 square foot area of compacted gravel storage area will be converted into a landscaped area; in exchange, the building addition will add 1,360 square foot of new impervious area. The net change is a decrease of 1,040 square foot of impervious area. Therefore, there are no water quality requirements. SECTION VI. CIT AND AGENCY COMMENTS The Tualatin Valley Fire District reviewed this application and stated that plans cannot be approved at this time: 1.) Provide details showing the fire department connection (FDC) to an automatic sprinkler system. FDC must be within 70-feet of the fire hydrant and at least 20-feet from the structure. General Telephone and Electronics (GTE) reviewed this application and stated that the developer, and/or owner, shall coordinate conduit requirements with GTE. No other comments have been received. NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 7 SECTION VII. PROCEDURE AND APPEAL INFORMATION Notice: Notice was posted at City Hall and mailed to: X The applicant and owners X Owners of record within the required distance X Affected government agencies Final Decision: THE DECISION SHALL BE FINAL ON APRIL 1, 1996 UNLESS AN APPEAL IS FILED. Appeal: Any party to the decision may appeal this decision in accordance with Section 18.32.290(A) and Section 18.32.370 of the Community Development Code that provides that a written appeal must be filed with the City Recorder within 10 days after notice is given and sent. The appeal fee schedule and forms are available from the Planning Division at Tigard City Hall, 13125 SW Hall Blvd., Tigard, Oregon 97223. The deadline for filing of an appeal is 3:30 p.m. on April 1, 1996. Questions: If you have questions, please call the City of Tigard Planning Department, Tigard City Hall, 13125 SW Hall Boulevard, Tigard, Oregon at (503) 639-4171. G////4///4 3/21/96 PREPARED BY: Mark Roberts DATE Associate Planner r L/ TLL -ems. 3/21/96 APPROVED BY: Richard Bewersdorff DATE Senior Planner NOTICE OF DECISION SDR 96-0004-SEVERSON WAREHOUSE PAGE 8 ID 0 SW HUNZIKER STREET U.On RIM.. I I 1 S 61.■ IA'i siem --r- 1 11 I 1 11 1 i 741 I * I 1 a w 2 I ■ :.I .! 1 ! Ce46CS. I ••• `N. 111.... ' CIL I t 1 I Ill S 1 oifrj3 I ce a d•0 00..,,- z, 0 af..,- a, I ' Cif0t.fi' ..e 1 1 . I 0 ,<•I !S!! I 1 2 D.' ; 7: g . ,..4' Z e i -I a OISIS., I : I to*OS .., ° 0'..ge. /;I I 1 1 574s'...- Z C II r 1 t 1......A...01/.... 3 .....k.; :t54r° / ....jr....,......-'. .IN I■—'--,-41,...,i--,4......2..-7:51'.....- ' —6 L.. , I QM ! / ,16"■• IMP ' ,,,,,i,;,..0 tat co AVA •:. tki" 00.1°- CI ■ 0P. .OS if I 7,4 I at 40 2,/ ., It* 'Ili' i es." Pos4) I / I 14' 141$ i <C(11 , 011.9.4. O.° 1 ...- 0 41:.°0-. , P4 / 04°1 1 1 1°''' 'II% ..... Nt. f, 1 I 1 IVO. . vs. ....' (.5 •<0 0 , 111,,tP 4 • 11..... I I 1/ ii suifil sti /6 ;1- i ,i IT IMIL --X-:--..N '...-., I. / •-........ '"-...._ i■! -....... 0:.- / II I ...// 111 ' - .‘.. -... .--,...‹,., ... ...._.,_, -,................< (1111) j 1 •-....... , ......_ i i PLOT PLAN CASE NO. EXHIBIT MAP SDR 96-0004 SEVERSON WAREHOUSE • w ›e\ _.., II "ma a 41 gs ,11.° p, ' ' /al '''t_ t 4, moriiiiiiiiir a mcfrw ir 8 , 1,%lot*"-/■ 0) 1 c •....... v.:A- . iii ii■v•■ 1 E , * /t w. ■ c 0 'P s • ;• a SUB! Cr � PARCE �-- s Ry�P$ s. 1- r 0 i Z' Mk 4 0 I Vicinity Map A SDR 96-000 �1 SEVERSON WAREHOUSE SDR 96-0004 SEVERSON WAREHOUSE (Page 1/1) IND 2S101BC-02100 EXHIBIT B ANNAND,JOHN D II&EDNA N 8260 SW HUNZIKER RD TIGARD,OR 97223 2S10100-00500 2S101BC-02200 GAZELEY, H WILLIAM H H O&B ASSOCIATES PO BOX 230414 14945 SW 72ND AVE TIGARD, OR 97281 TIGARD,OR 97223 2S101BC-02401 2S101BC-02700 KING, JAMES F KING,JAMES F 12650 SW HALL BOULEVARD PO BOX 23819 TIGARD, OR 97223 TIGARD,OR 97223 2S101BC-00100 2S101BC-02501 KNEZ, JOHN S SR&JEANNE M PALMER G LEWIS COMPANY 8185 SW HUNZIKER RD 525 C ST NW TIGARD, OR 97223 AUBURN,WA 98001 2S101BC-02201 2S101BC-02800 ROACH, MICHAEL A AND PAMELA S SEVERSON,JAMES A&ROBIN 0 210 CHANDLER PL 29404 SW HEATER RD LAKE OSWEGO,OR 97034 SHERWOOD,OR 97140 2S10100-00700 2S101BC-02500 SMITH GERIG WESTERN PROPERTIES SMITH GERIG WESTERN P IES 25440 SW NEWLAND RD 25440 SW D WILSONVILLE,OR 97070 IARLtONVILLE,OR 97070 2S101BC-00200 2S101BC-00201 U.S. NATURAL RESOURCES, INC WESTEC AMERICA INC PO BOX 23038 8255 SW HUNZIKER PORTLAND, OR 97223 TIGARD,OR 97223 2S101BC-02900 WESTPHAL, EDGAR A&PATRICE M 5218 WESTFIELD CT LAKE OSWEGO, OR 97035 k E c F l COMMUNITY NEWSPAPERS, INC. Legal P.O. BOX 370 PHONE(503)684-0360 Notice TT 8 4 3 0 MAE. 2 5 ggqf. BEAVERTON, OREGON 97075 ;RTY OF TJGA Legal Notice Advertising R!* •City of Tigard • ❑ Tearsheet Notice 13125 SW Hall Blvd. • Tigard ,Oregon 97223-8199 • ❑ Duplicate Affidavit *Accounts Payable :Terry • SITE DEVELOPMENT REVIEW(SDR)96-0004 SEVERSON WAREHOUSE The Director has approved, subject to conditions, a request for Site Development Review approval to allow the construction of a 12,600 AFFIDAVIT OF PUBLICATION square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 IBC, tax lot 2800). ZONE: Light Industrial (I-L).The I-L STATE OF OREGON, ) zoning allows public support facilities,building maintenance services, COUNTY OF WASHINGTON, )ss. manufacturing of finished products,packaging and processing,wholesale, Snyder storage,and distribution,among other uses. APPLICABLE REVIEW I, Kathy Y CRITERIA: Community Development Code Chapters 18.70, 18.100, being first duly sworn, depose and say that I am the Advertising 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. Director, or his principal clerk, of theTi gard—Tna 1 at i n Times -- a newspaper of general circulation as defined in ORS 193.010 II and 193.020; published at Tigard in the rr �aforesaid county and state; that the SDR 96-0004 Severson Warehousea printed copy of which is hereto annexed, was published in the *VII 1IUhi itrx\' entire issue of said newspaper for ONE successive and j� consecutive in the following issues: ♦ ■ 1�''"' March 21 , 1996 ■ III ,,�av, ► � A . , 'am •_•� .1 Ilt Subscribed and sworn to ore me this 2lst day of March, 191 ' Suu3 - T �,,11r1 / /� r G..4 PA E� '0 Notary lic for Oregon �� �' My Commission Expires: AFFIDAVIT i4Ill . • / The adopted finding of facts,decision,and statement of conditions can be obtained from the Planning Department,Tigard Civic Center, 13125 S.W. Hall Blvd.,Tigard,,Oregon 97223.The decision shall be final on April 1, 1996. Any party to the decision may appeal this decision in accordance with Section 18.32.290(A) and Section 18.32.370 of the Community Development Code, which provides that a written appeal may be filed within 10 days after notice is given and sent.The deadline for filing an appeal is 3:30 P.M.,April 1. 1996. 1T8430—Publish March 21, 1996. FAX TRANSMITTA' r DATE: March 15, 1996 TO: Mary White, Legals (fax)624-0338 FROM: Patricia Lunsford, City of Tigard (Ph.)639-4171 PLACE UNDER CITY OF TIGARD LOGO IN THE LEGALS SECTION SITE DEVELOPMENT REVIEW (SDR) 96-0004 ➢ SEVERSON WAREHOUSE The Director has approved, subject to conditions, a request for Site Development Review approval to allow the construction of a 12,600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. (PLACE VICINITY MAP HERE) The adopted finding of facts, decision, and statement of conditions can be obtained from the Planning Department, Tigard Civic Center, 13125 SW Hall Boulevard, Tigard, Oregon 97223. The decision shall be final on 4/1/96. Any party to the decision may appeal this decision in accordance with Section 18.32.290(A) and Section 18.32.370 of the Community Development Code, which provides that a written appeal may be filed within 10 days after notice is given and sent. The deadline for filing of an appeal is 3:30 PM 4/1/96. TT PUBLISH DATE: 3/21/96 SDR 96-0004 SEVERSON WAREHOUSE 9-Feb-96 PROPOSAL/REQUEST FOR COMMENTS „4.. .... ., J m miltivtitri////// 11„,. .,4*,,,,,,, w***, 4SIOIBC-00400 y iJip Mil --, 4S 1o16C-oo4ol tillil sSIOIBC-04400 48101 BC-00100 RSIOIBC-02201 IoIBC-04 •• I/ 2S10I113C•044O1 2SIOIBC-■ ••• C 4Sn ■ oo CO 2S101BC-02800 4SIOIBC-02700 ,`^• 4S10100-00600 4510111C-08501 vT 1-2, Co • F 2510100.00700 0 0 Vicinity Map NOTIFICATION MAP N SDR 96-0004 APPLICANT MATERIALS CITY OF TIGARD, OREGON SITE DEVELOPMENT REVIEW APPLICATION CITY OF TIGARD, 13125 SW Hall, PO Box 23397 Tigard, Oregon 97223 - (503) 639-4171 FOR STAFF USE ONLY CASE NO. '' (.- D o `( OTHER CASE NO'S: 6 „L 7�1 /< RECEIPT NO. 9'J6-e /cj / APPLICATION ACCEPTED BY: <7� DATE: Cj i 1. GENERAL INFORMATION Application elements submitted: PROPERTY ADDRESS/LOCATION V250 544/, JIL)4124 i2 —(A) Application form (1) Tj 6►42A I ` V B) Owner' s signature/written TAX MAP AND TAX LOT NO. PART PLC authorization i MFG Grimm (XS F 851 \ `a gal, I V (C) Title transfer instrument (1) SITE SIZE S!,36 5F, PROPERTY OWNER/DEED HOLDER* pnmeS OAS Robin, OSeve,:sDi1., E) lot plan (pre-app - p p pp checklist) ADDRESS aQ''I 0`( S 1/4.J \air 12c . PHONE (All- Applicant's statement .— CITY Che4vj 00cd , C Q) ZIP '714 Q (pre-app checklist) APPLICANT* 34„;,.vt 72.014;4 .-E,/ ,�jt/ V1'01(G) List of property owners and ADDRESS ZggP4 SW 4E-ATER ED PHONE 625-723I V addresses within 250 feet (1) CITY ic2Wppfl ZIP 97/90 (H) Filing fee ($ `)1 ) *When the owner and the applicant are different (I) Construction Cost Estimate people the applicant must be the Lass T `i�q�C p_ purchaser of record or a 1Qasee in possession with written authorization DATE DETERMINED TO BE COMPLETE: from the owner or an agent of the owner with written 7 — - authorization. The owner(s) must sign this application in the space provided on page two or FINAL DECISION DEADLINE: submit a written authorization with this application. COMP. PLAN ZONE DESIGNATION: 2. PROPOSAL SUMMARY r I- The owners of record of the subject property c -- request site development review approval to -47P74. Number: E.0. 121--- allow i Z,bPPSF Seed Approval Date: 1 / Irt Final Approval Date: Planning Engineering 0524P/13P Rev'd 5/87 _ 3. List any variance, conditional use, sensitive lands, or other land use actions to be considered as part of this application: /V111111.4— 4. Applicants: To have a complete application you will need to submit attachments described in the attached information sheet at the time you submit this application. 5. THE APPLICANT(S) SHALL CERTIFY THAT: A. The above request does not violate any deed restrictions that may be attached to or imposed upon the subject property. B. If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. C. All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted herewith, are true; and the applicants so acknowledge that any permit issued, based on this application, may be revoked if it is found that any such statements are false. D. The applicant has read the entire contents of the application, including the policies and criteria, and understands the requirements for approving or denying the application. DATED this day of 19?� SIGNATURES of each owner (eg. husband and wife) of the subject property. (KSL:pm/0524P) 6;PF0, (9Eutc-,0,4,)6 � �S ,y CCEP7 -pN 4oP/is?'7/c,V„ 7-1 toEsro•7 /cal- C ' '/& C P11.457- it-A E &JF/17 ( CLJ 6,)0(-)1c/ `7W -7a 55"e., O-61-1-6,, 7.7E7-4/ V'') 16--/-7-67e , (A1,1-64 i e"044 t6 4; ,fie, (?wL - Cfl coyvvuetel 7 W atita Cuf2 L-(1001 XIAAbleLCR—)4- eelr-f0C744/ CITY OF TIGARD PROPOSAL DESCRIPTION FILE NO: SITE DEVELOPMENT REVIEW (SDR) 96-0004 FILE TITLE: SEVERSON WAREHOUSE APPLICANT: Jim & Robin Severson OWNER: Same 29404 SW Heater Road Sherwood, OR 97140 (503) 625-7731 or (503) 684-0443 REQUEST: A request for Site Development Review approval to allow the construction of a 12.600 square foot warehouse building. LOCATION: 8250 SW Hunziker Street (WCTM 2S1 1 BC, tax lot 2800). ZONE: Light Industrial (I-L). The I-L zoning allows public support facilities, building maintenance services, manufacturing of finished products, packaging and processing, wholesale, storage, and distribution, among other uses. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.70, 18.100, 18.102, 18.106, 18.108, 18.114, 18.116, 18.120, 18.150 and 18.164. CIT: East CIT FACILITATOR: List Available Upon Request PHONE NUMBER: (503) DECISION MAKING BODY X STAFF DECISION PLANNING COMMISSION DATE OF HEARING: TIME: 7:30 HEARINGS OFFICER DATE OF HEARING: TIME: 7:00 CITY COUNCIL DATE OF HEARING: TIME: 7:30 RELATIVE COMPONENTS AVAILABLE FOR VIEWING IN THE PLANNING DIVISION X VICINITY MAP LANDSCAPING PLAN X NARRATIVE X X ARCHITECTURAL PLAN SITE PLAN X OTHER STAFF CONTACT: Mark Roberts (503) 639-4171 x317 SDR 96-0004 SEVERSON WAREHOUSE 8-Feb-96 PROPOSAL/REQUEST FOR COMMENTS CITY OF TIGARD January 24, 1996 OREGON Jim Severson 29404 SW Heater Road Sherwood, OR 97140 Re: Notice of Incomplete Submittal Dear Mr. Severson: The Planning Division has conducted a preliminary review of SDR 96-0004, an application for Site Development Review, and have found that certain application materials were not provided with the submittal. The Planning Division is unable to continue processing the application pending submission of the following items and plan notes: 1.) Topography and Grading Plan. 2.) Detailed Drainage Plan (which storm line will be used, what will the catch basin and roof be connected to, what off-site facilities are used?). If you have any questions concerning this information please feel free to contact me at 639-4171. Sincerely, William D'Andrea Assistant Planner h:Nogin1curpin1will\sdr96-04.hr 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639-4171 TDD (503) 684-2772 01-29-96 03:44PM P01 FAX 684-7297 hard copy to follow ? No.of pages incl. cover:_2_ TO: Mr.William D'Andrea DATE: January 29, 1996 Assistant Planner City of Tigard 13125 SW Hall Blvd. Tigard,OR 97223 FROM: John Matteson,A.I.A. COPIES TO: File Centrex w/attach. PROJECT: SDR 96-0004 Warehouse Development SUBJECT: Additional Information COPIES DATE DESCRIPTION, 1 1-29-96 Site Plan-reduced to 8.5x11 Mr.D'Andrea Per your letter dated January 24, 1996 to Jim Severson requesting additional information(noted with heavy rectangle box surrounding data): 1. Contour lines are indicated at 1-foot intervals. 2. Roof drains flow to new catch basin which flow to existing 10" storm line on- site. I spoke with Mr.Greg Berry 1-26-96 and he indicated that this was sufficient information. Please call me to confirm that this addresses your informational concern. Also,do I need to send 18 copies? Thank you for your assistance. John Matteson Matteson Architects 510 N.W.Third Avenue, Portland,Oregon 97209 (5031 224-6145 111=11111 I U.. ,1. 'I __._ miff ii 1 / , . Him 1 \. . . IM ill 0 if jam. \\ - .�;i� s _ IN ....., i - ' - \ 1� mss■ \ r' ill s i = im f0 He .,. .... •.;.. lino!I , . „... ,,,,\IN\ - .. .y, .. . . ._4 .i1 \ i\ a4�� / '' . li- ''S 1 iid r. a . u ICf �,4 �y y Al 5 `-- Pi -• ,---• ilill f ' illi la *10. -. .. ....•.,„s. BM; xl I. 23 1 ,,,, , ,,, ] « k ,s di' 1i'l 14 '411 ;1 ikili ic" ko i i ...... / "/ • 4 S • •UOUyr,UJyU0n0Oa,uuuuau OyllDUUMuc UGCUUODGODUUtluuOUOU VU000UUOCo0O1,y•1 . i ', i WAREHOUSE DEVELOPMENT PROJECT s• 4 r c ma CEHfkEx 00N514 VOWS IMC011PORATEG •. 111 ,; ■ 67606W.IWi1w Rod 1 i4rd,brow 47111•110■0 UI - '�'.. . ■.f' a .' v. - ■uuunuODU.,,onu.J0,,,,. puquuemu nnua yGUnonuuayououGGnuGyuo,-,,nyy.. • 70d 1dtt:£0 96-6Z-1U s r S � A R TO: Mr. William D'Andrea DATE: January 31, 1996 Assistant Planner City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 FROM: John Matteson, A.I.A. COPIES TO: File Centrex w/attach. PROJECT: SDR 96-0004 Warehouse Development SUBJECT: Drawing for Design Review COPIES DATE DESCRIPTION 18 1-31-96 Sheet#1 'Site Plan' (D size) with exterior building elevations. 1 1-31-96 8.5x11 reduced Sheet#1. REMARKS Mr. D'Andrea - Per our phone of 1-30-96,I have incorporated the site plan information I faxed to you 1-29-96 into the attached drawing. Please call if you have any questions. John Matt-son Matteson Architects 510 N.W.Third Avenue, Portland,Oregon 97209 (503) 224-6145 WraJVe, • ■ R • ■ r ■ • • ■ u • ■ • ■ ■ • • • M A T T S O N • A R C I I T E C T S January 16, 1996 Mr. Will D'Andrea, Assistant Planner Community Development Department 13125 SW Hall Blvd. Tigard, Oregon 97223 Re: Development Application for Warehouse Facility 510 NW THIRD 8250 SW Hunziker Road, Tigard, OR NW 1/4 Section 1, T.2S, R.1W, WM, Washington County, Oregon PORTLAND OREGON 97209 Dear Sir; 503 224 6145 Enclosed with this narrative are eighteen (18)copies of the site plan and exterior building elevations, dated 1-15-96, with project data indicating site area and landscape coverage. Also enclosed is a 8.5x11 xerox copy of the site plan sheet. Narrative describing the project: 1. ZONING DISTRICT DIMENSIONAL REQUIREMENTS Average width is more than 50'. Building height is less than 45'. Front setback is more than 30'. Site coverage is less than 85%. Landscape area is more than 15%. 2. SPECIAL BUILDING HEIGHT PROVISIONS Existing building and new building construction is 19,600 sq. ft.; site area for tax lot is 59,318 sq. ft., giving a floor area to site area ratio of 3:1 (meeting 1.5:1 requirement). Building height is 18'to eave, setbacks are 10' min., (exceeding 1/2 height to setback). The structure does not abut a residential zone district. 3. PARKING AND ACCESS Parking shown is 27 spaces. Building is divided into 3 tenant spaces: (3) warehouse areas of 9900 sq. ft. = 10 parking spaces; (3) patron areas of 2100 Sq. Ft. = 3 parking spaces; (3)offices of 600 Sq. Ft. = 3 parking spaces;total spaces required= 16. Parking space dimensions are 9'x18'. Handicap parking(2) spaces are provided and are van accessible. Bicycle rack(for two bicycles)is provided at the end of the walkway,protected for traffic. Main access to to parking area is via 30' right-of-way, with min. 24' paved width from Hunziker Road. 4. WALKWAY REQUIREMENTS Walkway is provided between structure and parking area-tire stops will be used to ensure 5' clearance. 5. LOADING AREA REQUIREMENTS Loading area to be determined by City Engineer. 6. CLEAR VISION AREA Clear vision between 3' and 8' height is provided at driveway and Hunziker Road. page 2 January 16, 1996 Mr. Will D'Andrea,Assistant Planner Community Development Department 7. BUFFERING AND SCREENING Screening around three sides of trash &recycling bins is provided by cyclone fencing with slats. 8. LANDSCAPING Trees are provided around the parking area,2" caliper: 1 per 7 parking spaces (4 trees), and north right-of-way. Low plantings are planned for south and east sides of the structure, without irrigation. 9. NEIGHBORHOOD MEETING A meeting was held Friday,January 12, 1996. Information attached. 10. RECYCLING Phone conversation with Mr. Lenny Hing on January 16th indicated that 10'x20' area, open one side, was adequate for trash and recycling. Site plan has been FAXed. 11. STORMWATER QUALITY Net change of existing impervious has been noted on Site Plan. 2400 sq. ft. of existing impervious gravel area has been changed to landscape area. 1360 sq. ft. of non-impervious site has been changed structure. Net change is 1040 sq. ft. gain of non-impervious ground. I believe this address the information on the Site Plan and Pre-Application Notes of December 21, 1995. Please feel free to contact me if I can provide additional information. Respectfully Submitted. John . attes b n, A.I.A. cc Centrex Construction TICOR TITLE 90- 45916 ) INSURANCE TICOR TITLE INSURANCE Washington County STATUTORY WARRANTY DEED JAMES F. KING Grantor, conveys and warrants to JAMES A. SEVERSON Grantee, the following described real property free of encumbrances except as specifically set forth herein situated in WASHINGTON County, Oregon, to wit: PARCEL 1, PARTITION PLAT NO. 1990-041, IN THE CITY OF 11GARD, WASINGTON COUNTY, OREGON THIS INSTRUMENT WILL NOT ALLOW USE OF THE PROPERTY DESCRIBED IN THIS INSTRUMENT IN VIOLATION OF APPLI- CABLE LAND USE LAWS AND REGULATIONS.BEFORE SIGNING OR ACCEPTING THIS INSTRUMENT,THE PERSON ACQUIR- ING FEE TITLE TO THE PROPERTY SHOULD CHECK WITH THE APPROPRIATE CITY Q OUNTY pLQNNJ G DEPARTMENT TO VERIFY APPROVED USES. The said property is free from encumbrances except ( OVNPN I S, CONDITIONS, RESTRICTIONS, RESERVATIONS, SET BACK LINES, POWERS OF SPECIAL DISTRICTS AND EASEMENTS OF RECORD, IF ANY. The true consideration for this conveyance is$ 211,307.40 (Here comply with the requirements of ORS 93.030) Dated this. `� day of//'/i�'L'r� 199e) .— � s n M c O TY JAME F. KING , , (' ' '.,212.°° -1 - - State of Oregon, County of Multnomah State of Oregon, County of The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this d day of August , 19 90 by day of , 19 by JAMES F. KING President and Secretary of a , corporation,0,72/ on behalf of the corporation. •otary PuOie iit,Oyfgdnc My comnuss`t`on ex`aires: , 01/16/91 Notary Public for Oregon ,� My commission expires: ' - • WW`A1VTY DEED STATE OF OREGON �. County of Washington SS JAMES F. 'K i)•"v , h► f t1' GRANTOR GRANTEE I,Donald W. Mason.Director of Assessment JAMES SEVERSON and Taxation and fF.X-Officio Recorder of Con- veyances for said cou�tty.f Oo hereby certify that Until a change is requested, all tax statements shall be the within instrument of writing,`wap received sent to the following address: and recorded,Iri book ofireCOfds of�.paid county. JAMES SEVERSON `=, D. Donald W` ast,;•,Director of 12900 SW PACIFIC HWY ‘ Assessment;and Taxation, Ex- T I GA RD, OR Officio County Clerk Escrow No Title No. J w IR ^bats • �7 573152SM 34-146435 , x 4-4,21.-,;,/ After recording return to: V) �-_ ,,!,=j _ JAMES SEVERSON � 0 _ , � z CUU0 ' i 12900 SW PACIFIC HWY 2'"`•,.... v TIGARD, OR Doc : 90045916 Rect: 39279 245. 00 08/24/1990 02: 28• 36PM Ticor Form No. 137 Statutory Warranty Deed 8/85 RECD OCT 0 2 1990 .asp - Name of applicant James A. Severson Subject Property: Tax Map and Lot Part Plat 1990-082, Lot 1 ; MapGrid: 655 F4 Address or General Location 8250 SW Hunziker Rd. ; Tigard, OR 97223 AFFIDAVIT OF POSTING NOTICE I. James A. Severson , do affirm that I am (represent) the party initiating interest In a prop 12,000 SF Metal Building Addi ti okf g the land located at 8250 SW Hunziker Rd. ; Tigard, and did on the day of , 19 personally post notice indicating that the site may be proposed for a Bui 1 ding Permit aAPiicatton, and the time, date and place of a neighborhood meeting to discuss the proposal. The sign was posted at 8250 SW Hunziker Rd. ; Tigard, Oregon (stare location on property) - This = day of J c�yt&. . 19= ; :; aPYgA/J- Sig re Subscribed and sworn to, affirmed. before me this day of dAvn ul , 19 (P tOru o.,--F!,--At I. E L Notary Public for the State of Oregon My Commission Expires: 1]_(.' _1'7 ^ C EGQN � . =, '. ; ,UN NO.025197 MY CC"•,i`<::• .+QP:EXPIRES JULY 30,1997 WITHIN SEVEN (7) CALENDAR DAYS OF THE SIGN POSTING, RETURN THIS AFFIDAVIT TO: City of Tigard Planning Division 13125 SW Hail Blvd Tigard, OR 97223 login\Jo\posa:ot t ac AFFIDAVIT OF MAILING STATE OF OREGON SS CITY OF TIGARD ) 1t James A. Severson , being duly sworn, depose and say that on )PCP1mbR-Y',D9 19 q Jr. 1 caused to have mailed to each of the persons on the attached fist a notice of a meeting to discuss a proposed development at 8250 SW Hunzi ker Road; Ti gard, OR a copy of which notice so mailed is attached hereto and made a part of hereof. t further state that said notices were enclosed in envelopes plainly addressed to said persons and were deposited on the date indicated above in the United States Post Office at Tigard, OR with postage prepaid thereon. Signs Subscribed and sworn to before me this '"`. C.f day of 04C�UYYL--Q%L , 19 G� . - .t.„"k_AL. r '' h OFFICIAL SEAL Notary blic ,�1_ L JODI WHITE f NOTARY PUBLIC-OREGON My Ca mission Expires: f `- 7 6 f MMISS MISSION EXPIRES NO.025197 30,1997 f MY h:\fccin\jo\aifrnail.=t CENTREX CONSTRUCTION INCORPORATED December 29, 1995 Manuel and Dioema Solis 8335 SW Hunziker Road Tigard, OR 97223 0(Th RE: Warehouse at 8250 SW Hunziker Rd. by James A. Severson and Centrex Construction, Inc. Dear Interested Party: James A. Severson is the owner of the property located at 8250 SW Hunziker Road; Tigard, Oregon 97223. I am considering proposing to build a 12,000 SF warehouse at this location. Prior to applying to the City of Tigard for the necessary permits, I would like to discuss the proposal in more detail with the surrounding property owners and residents. You are invited to attend a meeting on: Friday, January 12, 1996 4:00 PM 8250 SW Hunziker Road Tigard, Oregon Please notice this will be an informational meeting on preliminary plans. These plans may be altered prior to the submittal of the application to the City. I look forward to more specifically discussing the proposal with you. Please call me at 684- 0443 if you have any questions. Sincerely, James A. Severson 8250 S.W.HUNZIKER RD. • TIGARD,OREGON 97223-5060 • TELEPHONE(503)684-0443 • FAX(503)620-6692 Mary Swintek Craig Hopkins Mark F. Mahon 9915 SW Frewing #23 7430 SW Varns Street 11310 SW 91st Court Tigard, OR 97223 Tigard, OR 97223 Tigard, OR 97223 Joel Stevens Pat Wyden John and Edna Annand 9660 SW Ventura Court 8122 SW Spruce Street 8260 SW Hunziker Road Tigard, OR 97223 Tigard, OR 97223 Tigard, OR 97223 Michael and Pamela Roach John and Jeanne Knez Gerig Smith; Western Properties 210 Chandler Place 8185 SW Hunziker Road 25440 SW Newland Road Lake Oswego, OR 97034 Tigard, OR 97223 Wilsonville, OR 97070 Edgar and Patrice Westphal Westec America, Inc. Owner; Palmer G. Lewis Co. 5218 Westfield Court 8255 SW Hunziker Road P.O. Box 23159 Lake Oswego, OR 97035 Tigard, OR 97223 Tigard, OR 97223 Jim King; Snyder Roofing Co. Manuel and Dioema Solis 12650 SW Hall Blvd. 8335 SW Hunziker Road Tigard, OR 97223 Tigard, OR 97223 1/ 1x1 Al 4 M ?hvo e sal Jat -si-- .)A. ,t..„... rJn,,_lfl(A,R)Co2o- 8ColoB 82Cno ;.,..). Hurz.i IAE.g Q /3.-,.: , r-3?-1 (kJ xds, wj ) c<JP- d,ao .1-.2_ (.2 S (Ai., Z , ,e,, 3.. P', ems` 0 '' e( (( ,( ce- ,-( -1 "..1C/t.v' .. (4____ 0,,,, ,,,,/ c„,_,_.,* tr r1 1 , 0 Ii )3,. I L, tS I I 7• January 12, 1996 Meeting Notes: In attendance: James A. Severson; Owner 8250 SW Hunziker Road Tigard, Oregon John & Edna Annand 8260 SW Hunziker Rd. Tigard, Oregon Rex Gerig 8200 SW Hunziker Road Tigard, Oregon Brian Smith 8200 SW Hunziker Road Tigard, Oregon Comments and Questions: John and Edna Annand; Liked the plan to improve the land, said it would increase value of everyone's property. Brian Smith and Rex Gerig; Asked about landscaping and drainage. Landscaping will be at least 15%. Drainage: Catch basin will be installed to improve drainage. Easement area will remain graded and rocked. Commented that improvement to land would increase the value of their property. PRE - APPLICATION CONFERENCE NOTES CITY OF TIGARD PRE-APPLICATION CONFERENCE NOTES NON-RESIDENTIAL •'+ �, /� A8 TT CITY OF TIGARD / DATE: ' - a .C/ 5 STAFF: �l/ 34/6 APPLICANT: AGENT: 1- h /W47 430N Phone: ( ) Phone: ( ) aaq- (p I S PROPERTY LOCATION ADDRESS: 825O 5 ) TAX MAPITAX LOT: NECESSARY APPLICATION(S): Z -e/,2t '0.✓7Fat1P XEU/6'1 ) PROPOSAL DESCRIPTION: fad, GC10 141,4tE//conE. COMPREHENSIVE PLAN DESIGNATION: .T- L ZONING DESIGNATION: L- CITIZEN INVOLVEMENT FACILITATOR: TEAM AREA: EAST' PHONE: (503) ZONING DISTRICT DIMENSIONAL REQUIREMENTS Minimum lot size: � sq. ft. Average lot width: 50 ft. Maximum building height: 40" ft. Setbacks: front 30 ft. side ft. rear ft. corner `' ft. from street. Maximum site coverage: SS °'o Minimum landscaped or natural vegetation area: /4 % (Refer to Code Section 18.70 ) ADDITIONAL LOT DIMENSIONAL REQUIREMENTS Minimum lot frontage: 25 feet,unless lot is created through the minor land partition process. Lots created as part of a partition must have a minimum of 15 feet of frontage or have a minimum 15 foot wide access easement. CITY OF TIGARD Pre-Application Conference Notes Page 1 of 6 NON-Residential aoplicationiPlanning Department Section The depth of all lots shall not _ ..eed 2',V2 times the average width, unless the , _. el is less than 1'/r times the minimum lot size of the applicable zoning district. (Refer to Code Section 18.164.060 Lots) SPECIAL SETBACKS • Streets: S 6 feet from the centerline of ilVA/Z/ • Established areas: ..feet from • Lower intensity zones: feet, along the site's boundary. • Flag lot: 10 foot side Bard setback. (Refer to Code Section 18.106.040 and 18.96) SPECIAL BUILDING HEIGHT PROVISIONS Building Height Exceptions - Buildings located in a non-residential zone may be built to a height of 75 feet provided: • A maximum building floor area to site area ratio (FAR) of 1.5 to 1 will exist; • All actual building setbacks will be at least Y2 (half) of the building's height; and • The structure will not abut a residential zone district. (Refer to Code Section 18.98.020) v)(404— 57. 41 2'574. PARKING AND ACCESS Parking shown on preliminary plan(s): Required parking for this type of use: I : /OOC) eta IAJAA. Secondary use required parking: 1% 7 77,17.A�•✓ 1 = AC* O FFrc.6 r¢rZa.4 No more than 40% of required spaces may be designated andlor dimensioned as compact spaces. Parking stalls shall be dimensioned as follows: • Standard parking space dimensions: 8 ft. 8 inches X 18 ft. • Compact parking space dimensions: 8 ft. X 15 ft. (Refer to Code Section 18.106.020) • Handicapped parking: All parking areas shall provide appropriately located and dimensioned disabled person parking spaces. The minimum number of disabled person parking spaces to be provided, as well as the parking stall dimensions, are mandated by the Americans with Disabilities Act (ADA). A handout is available upon request. A handicapped parking space symbol shall be painted on the parking space surface and an appropriate sign shall be posted. Bicycle racks are required for multi-family, commercial and industrial developments. Bicycle racks shall be located in areas protected from automobile traffic and in convenient locations. Bicycle parking spaces shall be provided on the basis of one space for every fifteen (15) required vehicular parking spaces. Minimum number of accesses: f Minimum access width: Minimum pavement width: aY All driveways and parking areas, except for some fleet storage parking areas, must be paved. Drive-in use queuing areas: (Refer to Code Section 18.106 and 18.108) CITY OF TIGARD Pre-Application Conference Notes Page 2 of 6 NON-Residential applicationtPlanning Department Section WALKWAY REQUIREMENTS ""rrl Walkways shall extend from the ground floor entrances or from the ground floor landing of stairs, ramps, or elevators of all commercial, institutional, and industrial uses, to the streets which provide the required access and egress. Walkways shall provide convenient connections between buildings in multi-building commercial, institutional, and industrial compleses. Unless impractical, walkways should be constructed between a new develpment and neighboring developments. (Refer to Code Section 18.108.050) JIOADING AREA REQUIREMENTS Every commercial or industrial building in excess of 10,000 square feet shall he provided with a loading space. The space size and location shall be as approved by the City Engineer. (Refer to Code Section 18.106.070.090) CLEAR VISION AREA A The City requires that clear vision areas be maintained between three and eight feet in height at road/driveway, road/railroad, and road/road intersections. The size of the required clear vision area depends upon the abutting street's functional classification. (Refer to Code Section 18.102) BUFFERING AND SCREENING In order to increase privacy and to either reduce or eliminate adverse noise or visual impacts between adjacent developments, especially between different land uses, the City requires landscaped buffer areas along certain site perimeters. Required buffer areas are described by the Code in terms of width. Buffer areas must be occupied by a mixture of deciduous and evergreen trees and shrubs and must also achieve a balance between vertical and horizontal plantings. Site obscuring screens or fences may also be required; these are often advisable even if not required by the Code. The required buffer areas may only be occupied by vegetation, fences, utilities, and walkways. Additional information on required buffer area materials and sizes may be found in the Community Development Code. (Refer to Code Chapter 18.100) The required buffer widths which are applicable to your proposal area are as follows: ft. along north boundary. ft. along east boundary. ft. along south boundary. ft. along west boundary. In addition, sight obscuring screening is required along `'X4.5.4' 7 ReG�/G/!,1' few//-4' LANDSCAPING /l1 Street trees are required for all developments fronting on a public or private street as well as driveways which are more than 100 feet in length. Street trees must be placed either within the public right-of-way or on private property within six feet of the right-of-way boundary. Street trees must have a minimum caliper of at least two inches when measured four feet above grade. Street trees should be spaced 20 to 40 feet apart depending on the branching width of the proposed tree species at maturity. Further information on regulations affecting street trees may be obtained from the Planning Division. A minimum of one tree for every seven parking spaces must be planted in and around all parking areas in order to provide a vegetative / canopy effect.randscaped parking-Teas shall include special design features which effectively screen the parking lot areas from view. These design features may include the use of landscaped berms, decorative walls, and raised planters. For detailed information on design requirements for parking areas and accesses. (Refer to Code Chapters 18.100, 18.106 and 18.108) CITY OF TIGARD Pre-Application Conference Notes Page 3 of 6 NON-Residential application(Planning Department Section SIGNS • Sign permits must be obtaineo ,..nor to installation of any sign in the City of ..yard. A "Guidelines for Sign Permits" handout is available upon request. Additional sign area or height beyond Code standards may be permitted if the sign proposal is reviewed as part of a development review application. Alternatively, a Sign Code Exception application may be filed for review before the Hearings Officer. (Refer to Code Section 18.114) SENSITIVE LANDS The Code provides regulations for lands which are potentially unsuitable for development due to areas within the 100-year floodplain, natural drainageways, wetland areas, on slopes in excess of 25 percent, or on unstable ground. Staff will attempt to preliminarily identify sensitive lands areas at the pre-application conference based on available information. HOWEVER, the responsibility to precisely identify sensitive lands areas, and their boundaries, is the responsibility of the applicant. Areas meeting the definitions of sensitive lands must be clearly indicated on plans submitted with the development application. Chapter 18.84 also provides regulations for the use, protection, or modification of sensitive lands areas. Residential development is prohibited within floodplains. In most cases, dedication of 100-year floodplain areas to the City for park and open space areas is required as a condition of the approval of a development application. (Refer to Code Section 18.84) NARRATIVE '''T The applicant shall submit a narrative which provides findings based on the applicable approval standards. Failure to provide a narrative or adequately address criteria would be reason to consider an application incomplete and delay review of the proposal. (Refer to Code Section 18.32) CODE SECTIONS 18.80 18.98 _ 18.114 18.150 18.84 4--18.100 18.116 18.160 18.88 _. 18.102 / 18.120 18.162 18.92 18.106 18.130 Imo- 18.164 18.96 -- 18.108 18.134 NEIGHBORHOOD MEETING 7 The applicant shall notify all property owners within 250 feet and the appropriate CIT Facilitator and the members of any land use subcommittees) of their proposal. A minimum of 2 weeks between the mailing date and the meeting date is required. Please review the Land Use Notification handout concerning site posting and the meeting notice. Meeting is to be held prior to submitting your application or the application will not be accepted. RECYCLING Applicant should contact franchise hauler for review and approval of site servicing compatibility with Pride Disposal's vehicles. CONTACT PERSON: Lenny Hing with Pride Disposal at (503) 625-6177. (Refer to Code Section 18.116) CITY OF TIGARD Pre-Application Conference Notes Page 4 of 6 NON-Residential aoplicationIPlannmq Department Section ADDITIONAL CONCERNS OR CUMML._,S: Ae717/ r' «$0- gy O� -s M.. (I 7.47e kN& zor - PROCEDURE / Administrative staff review. Public hearing before the Land Use Hearings Officer. Public hearing before the Planning Commission. Public hearing before the Planning Commission with the Commission making a recommendation on the proposal to the City Council. An additional public hearing shall be held by the City Council. APPLICATION SUBMITTAL PROCESS All applications must be accepted by a Planning Division staff member of the Community Development Department at Tigard City Hall offices. PLEASE NOTE: Applications submitted by mail or dropped off at the counter without Planning Division acceptance may be returned. Applications submitted after 4:30 P.M. on Thursday will be batched for processing with the following week's applications. Applications will NOT be accepted after 3:00 P.M. on Fridays or 4:30 on other days. Maps submitted with an application shall be folded IN ADVANCE to 8.5 by 11 inches. One 8.5 inch by 11 inch map of a proposed project should be submitted for attachment to the staff report or administrative decision. Application with unfolded maps shall not be accepted. CITY OF TIGARD Pre-Application Conference Notes Page 5 of 6 NON-Residential app!ication,P!anning Department Section • The Planning Division and Engineering Division will perform a preliminary review of the application and will determine whether an application is complete within 30 days of the counter submittal. Staff will notify the applicant if additional information or additional copies of the submitted materials are required. The administrative decision or public hearing will typically occur approximately 45 to 60 days after an application is accepted as being complete by the Planning Division. Applications involving difficult or protracted issues or requiring review by other jurisdictions may take additional time to review. Written recommendations from the Planning staff are issued seven (7) days prior to the public hearing. A 10, to 20 day public appeal period follows all land use decisions. An appeal on this matter would be heard by the Tigard Z'd4A/A/fl /6_ GC.411V115S/0A/. A basic flow chart which illustrates the review process is available from the Planning Division upon request. This pre-application conference and the notes of the conference are intended to inform the prospective applicant of the primary Community Development Code requirements applicable to the potential development of a particular site and to allow the City staff and prospective applicant to discuss the opportunities and constraints affecting development of the site. PLEASE NOTE: The conference and notes cannot cover all Code requirements and aspects ...:.. ...................... .... .................................. of good site planning that should apply to the development of your site plan. Failure of the staff to provide information required by the Code shall not constitute a waiver of the applicable standards or requirements. It is recommended that a prospective applicant either obtain and read the Community Development Code or ask any questions of City staff relative to Code requirements prior to submitting an application. Additional pre-application conferencels) islare required if an application(s) islare to be submitted more than six months following this pre-application conference, unless the additional conference(s) is deemed as unnecessary by the Planning Division. PREPARED BY: �'Y/ DkJlQl1 CITY OF TIGARD PLANNING DIVISION PHONE: (503) 639-4171 FAX: (503) 684-7297 h:.!ogim,patty mastersioreaaptmst ,Engmeenng Section:masterslpreapp-c.engl CITY OF TIGARD Pre-Application Conference Notes Page 6 of 6 NON-Residential appiicationiP!anning Department Section PUBLIC FACILITIES . r,,.tl, CITY OF TIGARD The purpose of the pre-application conference is to: OREGON (1.) Identify applicable Comprehensive Plan policies and ordinance provisions. (2.) To provide City staff an opportunity to comment on specific concerns. (3.) Ta review the Land Use Application review process with the applicant and to identify who the final decision making authority shall be for the application. The extent of necessary public improvements and dedications which shall be required of the applicant will be recommended IT; City staff and subject to approval by the appropriate authority. There will be na final recommendation to the decision making authority on behalf of the City staff until all concerned commenting agencies. City staff and the public have had an opportunit, to review and comment an the application. The following comments are a projection of public improvement related requirements that may be required as a condition of development approval for your proposed project. Right-of•way dedication: The City of Tigard requires that land area be dedicated to the public: (1.) To increase abutting public rights-of-way to the ultimate functional street classification right-of-way width as specified by the Community Development Code; or (2.) For the creation of new streets. Approval of a development application for this site will require right-of-way dedication for: (1.) to 3 0 feet from centerline. c.. 4 �eA-st (2.) to feet from centerline. (3.) to feet from centerline. Street improvements: street improvements will be necessary along "j (2.) street improvements will be necessary along (3.) Street improvements shall include feet of pavement from centerline, plus the instailation of curb and gutters, storm sewers, underground placement of utility wires (a fee may be collected if determined appropriate by the Engineering Department), a five-foot wide sidewalk (sidewalks may be required to be wider on arterials or major collector streets, or in the Central Business District), necessary street signs, streetlights, and a two year streetlighting fee. CITY OF TIGARD Pre-Application Conference 'dates Page 1 or 3 3eacennai -oeucanocuc:^,reernq.eoartrent Lect.cn In some cases, where strP 'mprovements or other necessary public i• vements are not currently practical, the stye: improvements may be defers In such cases, a condition of development . .,val may be specified which requires the proper owner(s) to execute a non-remonstrance agreement which waives the property owner's right to remonstrate against the formatio of a local improvement district formed to improve: (1.) (2.) Pedestrianwayslbikeways: Sanitary Sewers: The nearest sanitary sewer line to this property is a(n) inch line which is located in . The proposed development must be connected to a sanitary sewer. It the developer's responsibility to extend the sewer along the proposed development site's . i/L 4...._ £4 40, Cal Water Supply: The Water District . Phone:(503) provides public water service in thf area of this site. The District should be contacted for information regarding water supply for your proposes development. Fire Protection: Tualatin Valley Fire and Rescue District (Contact: Gene Birchill, (503) 526.2502) provides fire protectioi services within the City of Tigard. The District should be contacted for information regarding the adequac‘ of circulation systems, the need for fire hydrants, or other questions related to fire protection. Other Agency Permits: Storm sewer improvements: .t ,e,.t...-;yr �c� STORMWATER QUALITY FEES The Unified Sewerage Agency has established, and the City has agreed to enforce, Resolution No. 90-43 Surface Water Management Regulations which requires the construction of on-site water quality facilities. At the discretion of the City, thf applicant may be offered an opportunity to pay a fee in lieu of the construction of such a facility. The resolution requires the construction of a water quality facility andlor the payment of a fee. The fee shall be based upon the amount of impervious surface; for every 2,540 square feet, or portion thereof, the fee shall be $285.00. The City of Tigard shall determine is a fee may be paid or a facility shall be constructed. e> Syr-vnsz-, 0- ,. CITY OF TIGARD Pre-Appiication Conference Votes Page 2 of 3 Residential,AoaicatIomeagmeenng:eoartment:anon TRAFFIC IMPACT FEES In 1990, Washington County adopted a countywide Traffic Impact Fee (T1F) ordinance. The Traffic Impact Fee program collect: fees from new development based on the development's projected impact upon the City's transportation system. The applicon shall be required to pay a fee based upon the numoer of trips which are projected to result from the proposed development. The calculation of the TIF is based on the proposed use of the land, the size of the project, and a general use based fe! category. The TIF shall be calculated at the time of building permit issuance. In limited circumstances, payment of the TIF ma% be allowed to be deferred until the issuance of an occupancy permit. Deferral of the payment until occupancy is permissible only when the TIF is greater than $5,000.00. STREET OPENING PERMIT No work shall be preformed within a public right-of-way, or shall commence, until the applicant has obtained a street openinc permit from the Engineering Department. FINISHED FLOOR ELEVATIONS All projects that require a grading pla Iso reouire that the applicant shall submit a typical floor plan for each lot. This floor plan shall indicate the elevations of the t corners of that plan along with elevations at the corner of each lot. PREPARED BY: A/u ENGitERING DIVISION PHONE: (503) 539.4171 raogrmpattyi preaop.ms: engsec:wn reapaeng; .anuary 11. 12E. C:TY OF TIGARD Pre-Application Conference 'dates Page 3 of 3 iesidentral :eoiic]ncruEngtneenng Jecarment 3enan CITY OF TIGARD COMMUNITY DEVELOPMENT DEPARTMENT APPLICATION CHECKLIST CITY OF TIGARD The items on the checklist below are required for the succesful completion of your application submission requirements. This checklist identifies what is required to be submitted with your application. This sheet MUST be returned and submitted with all other applicable materials at the time you submit your land use application. See your application for further explanation of these items or call the City of Tigard Planning Division at (503) 639-4171. Staff: e// r a/, Date: /G-!q-q5 APPLICATION & RELATED DOCUMENT(S) SUBMITTAL REQUIREMENTS INCLUDE ,/ MARKED ITEMS A) Application form (1 copy) I� B) Owner's signature/written authorization et'' C) Title transfer instrument/or grant deed er' D) Applicant's statement No. of Copies ) E) Filing Fee $ SEE- FEL SCtS1x)t 6 SITE-SPECIFIC MAP(S)/PLAN(S) SUBMITTAL REQUIREMENTS INCLUDE ,/ MARKED ITEMS A) Site Information showing: No. of Copies / 1 . Vicinity map I� 2. Site size & dimensions I� 3. Contour lines (2 ft at 0-10% or 5 ft for grades > 10%) rY 4. Drainage patterns, courses, and ponds 5. Locations of natural hazard areas including: ❑ (a) Floodplain areas ❑ (b) Slopes in excess of 25% ❑ (c) Unstable ground ❑ (d) Areas with high seasonal water table ❑ (e) Areas with severe soil erosion potential ❑ (f) Areas having severely weak foundation soils ❑ 6. Location of resource areas as shown on the Comprehensive Map Inventory including: ❑ (a) Wildlife habitats ❑ (b) Wetlands ❑ 7. Other site features: (a) Rock outcroppings ❑ (b) Trees with 6" + caliper measured 4 feet from ground level yam' 8. Location of existing structures and their uses 9. Location and type of on and off-site noise sources tie 10. Location of existing utilities and easements I� 1 1 . Location of existing dedicated right-of-ways �( LAND USE APPLICATION/LIST PAGE 1 OF 5 B) Site Developme,.. Plan Indicating: No. of Copies 1B 1. The proposed site and surrounding properties 2. Contour line intervals e" 3. The location, dimensions and names of all: (a) Existing & platted streets & other public ways and easements on the site and on adjoining properties (b) Proposed streets or other public ways & easements on the site r8/ (c) Alternative routes of dead end or proposed streets that require future extension 4. The location and dimension of: (a) Entrances and exits on the site GiV (b) Parking and circulation areas p� (c) Loading and services area (d) Pedestrian and bicycle circulation ❑ (e) Outdoor common areas (f) Above ground utilities o' 5. The location, dimensions & setback distances of all: (a) Existing permanent structures, improvements, utilities, and easements which are located on the site and on adjacent property within 25 feet of the site (b) Proposed structures, improvements, utilities and easements on the site 6. Storm drainage facilities and analysis of downstream conditions ge• 7. Sanitary sewer facilities y� 8. The location areas to be landscaped gee 9. The location and type of outdoor lighting considering crime prevention techniques 10. The location of mailboxes ❑ 11 . The location of all structures and their orientation 12. Existing or proposed sewer reimbursement agreements ❑ C) Grading Plan Indicating: No. of Copies / The site development plan shall include a grading plan at the same scale as the site analysis drawings and shall contain the following information: 1 . The location and extent to which grading will take place indicating: (a) General contour lines (b) Slope ratios ❑ (c) Soil stabilization proposal(s) ❑ (d) Approximate time of year for the proposed site development 2. A statement from a registered engineer supported by data factual substantiating: (a) Subsurface exploration and geotechnical engineering report ❑ (b) The validity of sanitary sewer and storm drainage service proposals el (c) That all problems will be mitigated and how they will be mitigated ❑ LAND USE APPLICATION/LIST PAGE 2 OF 5 D) Architectural I'ings Indicating: No. of Copies 18 The site develop_ cent plan proposal shall include: 1 . Floor plans indicating the square footage of all structures proposed for use on-site 2. Typical elevation drawings of each structure E) Landscape Plan Indicating: No. of Copies 18 The landscape plan shall be drawn at the same scale of the site analysis plan or a larger scale if necessary and shall indicate: 1 . Description of the irrigation system where applicable 2. Location and height of fences, buffers and screenings Er' 3. Location of terraces, decks, shelters, play areas, and common open spaces ®" 4. Location, type, size and species of existing and proposed plant materials v" 5. Landscape narrative which also addresses: (a) Soil conditions ❑ (b) Erosion control measures that will be used ❑ F) Sign Drawings: ❑ Sign drawings shall be submitted in accordance with Chapter 18.114 of the Code as part of the Site Development Review or prior to obtaining a Building Permit to construct a sign. G) Traffic Generation Estimate: ❑ H) Preliminary Partition/Lot Lin- Ad'ustment Ma. Indicatin•: No. of Copies 1 . The owner of the subje parcel ❑ 2. The owner's authorized :gent ❑ 3. The map scale (20,50,1 .0 or 200 feet= 1) inch north arrow and date ❑ 4. Description of parcel location and boundaries ❑ 5. Location, width and na es of streets, easements and other public ways within and adjace t to the parcel ❑ 6. Location of all permane t buildings on and within 25 feet of all property lines ❑ 7. Location and width of al water courses ❑ 8. Location of any trees wit in 6" or greater caliper at 4 feet above ground level ❑ 9. All slopes greater than 25'0 ❑ 10. Location of existing utiliti-s and utility easements ❑ 11. For major land partition w ich creates a public street: (a) The proposed right-o -way location and width ❑ (b) A scaled cross-sectio of the proposed street plus any reserve strip ❑ 12. Any applicable deed restric ions ❑ 13. Evidence that land partition will not preclude efficient future land division where applicable ❑ LAND USE APPLICATION/LIST PACE 3 OF 5 . I) Subdivision Pre' 'nary Plat Map and Data Indicatin No. of Copies 1 . Scale equaling 30,50,100 or 200 feet to the inch and limited to one phase per sheet ❑ 2. The proposed name of the s bdivision ❑ 3. Vicinity map showing prope 's relationship to arterial and collector streets ❑ 4. Names, addresses and teleph ne numbers of the owner, developer, engineer, surveyer and desig er (as applicable) ❑ 5. Date of application ❑ 6. Boundary lines of tract to b subdivided ❑ 7. Names of adjacent subdivisi n or names of recorded owners of adjoining parcels of un-subd vided land ❑ 8. Contour lines related to a Ci -established benchmark at 2-foot intervals for 0-10% grades greater th 10 9a ❑ 9. The purpose, location, type nd size of all the following (within and adjacent to the proposed su division): (a) Public and private rig t-of-ways and easements ❑ (b) Public and private sa itary and storm sewer lines ❑ (c) Domestic water main including fire hydrants ❑ (d) Major power telepho a transmission lines (50,000 volts or greater) ❑ (e) Watercourses ❑ (f) Deed reservations f parks, open spaces, pathways and other land encumbrances ❑ 10. Approximate plan and pr.files of proposed sanitary and storm sewers with grades and pipe siz,s indicated on the plans ❑ 11 . Plan of the proposed wa -r distribution system, showing pipe sizes and the location of valves an. fire hydrants ❑ 12. Approximate centerline .rofiles showing the finished grade of all streets including street extensi• s for a reasonable distance beyond the limits of the proposed subdivisio ❑ 13. Scaled cross sections of proposed street right-of-way(s) ❑ 14. The location of all area subject to inundation or storm water overflow ❑ 15. Location, width & dire ion of flow of all water courses & drainage-ways ❑ 16. The proposed lot confi: rations, approximate lot dimensions and lot numbers. Where lo s are to be used for purposes other than residential, it shall be i dicated upon such lots. 17. The location of all tree. with a diameter 6 inches or greater measured at 4 feet above ground le el, and the location of proposed tree plantings ❑ 18. The existing uses of the property, including the location of all structures and the present uses o' the structures, and a statement of which structures are to remain after pia, ing ❑ 19. Supplemental informat on including: (a) Proposed deed n strictions (if any) ❑ (b) Proof of propert ownership ❑ (c) A proposed plan for provision of subdivision improvements ❑ 20. Existing natural features I cluding rock outcroppings, wetlands & marsh areas ❑ 21 . If any of the foregoing nformation cannot practicably be shown on the preliminary plat, it shall be incorporated into a narrative and submitted with the application ❑ LAND USE APPLICATION J LIST PACE 4 OF 5 J) Solar Access Calcul ions: ❑ K) Other Information No. of Copies ❑ • h login\patty\mastersU<itlist.mst May 23, 1995 LAND USE APPLICATION./LIST PAGE 5 OF 5 ' I ' o '' — �i U /' ,~�-___ I V 7--"7" / '� / - _-~-� I / . � v. H ___.... ,..I , _ ,t- I Ii 1 ----t---------------"-------"4 "-..---"4:4. _Ii....7.../...„ ,So■CH-1LI7A1 61.441„i' JIA„). ' :7 ::: I 7,1 ______Tff______________i. _ . ./.._ \I/lc. c***------------- CA ya /74/."../...:'.:*.Z1".... 4.-- f).\. .\- 1 r --------T 1 St i'fy il i- ----- . .a l /."*.. / r a) y .1 . . i.) it,,99,,.., s,..1,„90e49 . 1 / ...„ -NN ., „.... . , 5 ,.>" F.-----,...,rs. —I AUN j4/;,,,v I 4-2 i gi ...... 4... ....\ 0 --.... /47\\, \ c, : i ,/ N}I l. /LI: 1 .., 1, 0 , / : 1 , -...,._ ,.4, ''''C. t"r.‘, I I / ,v) ,, • 111111111EM • 111011/ 19111M111 • 111111 • 111111 M A T T S O N • A R C I I T E C T S l ' December 15, 1995 City of Tigard Community Development Department 13125 SW Hall Blvd. Tigard, Oregon 97223 Re: Development Review for Warehouse Facility 510 NW THIRD 8250 SW Hunziker Road, Tigard, OR NW 1/4 Section 1, T.2S, R.1W, WM, Washington County, Oregon PORTLAND OREGON 97209 Dear Sir; 503 224 6145 Enclosed with this letter are two copies of the site plan,20th scale, dated 12-7-95, with project data indicating site area and landscape coverage. Also enclosed is a 8.5x11 xerox copy of the boundary survey indicating square footage of the site (parcels 1 and 3). The project will consist of the following work: 1. Extend existing paved driveway, storm, sanitary, water,fire line, power, and other services to new development. 2. Construct new single story pre-engineered metal warehouse building with fire sprinklers, of approximately 12,600 square feet, slab-on-grade. 3. Provide 27 parking space, 9'x18'. Two spaces to be handicap, van accessible. 4. New landscaping to be approximately 4300 square feet,combined with existing (4750 square feet)will provide over 15% of site area. 5. The site is relative flat and surface drainage will be to a new catch basin and tie into existing storm system. Please feel free to contact me if I can provide additional information. Respectfully submitted. — Joh Matte on, A.I.A. cc ntrex Construction s M a ce6- 00oy � r / F RECEIVED R 2 ?qq6 COMMUNITY DEVELOPMENT A TO: Mr.Mark Roberts DATE: March 22, 1996 Associate Planner City of Tigard 13125 SW Hall Blvd. Tigard,OR 97223 FROM: John Matteson, A.I.A. COPIES TO: File Centrex w/attach. PROJECT: SDR 96-0004 Warehouse Development SUBJECT: Site Plan - Revised COPIES DATE DESCRIPTION 1 3-2-96 Sheet#1 'Site Plan' (D size)with revisions per your FAX comments of 3-21-96. 1 1-16-96 Approved site plan (8.5x11 reduced Sheet#1; for trash per Pride Disposal by Lenny Hing. REMARKS Mr. Roberts - Per our phone of 3-22-96,I have revised the site plan per your FAX and attach a copy of the approved trash enclosure(size and location). Please call if you have any questions. Thank you for your assistance. John Matteson r." _ Matteson Architects 510 N.W.Third Avenue. Portland, Oregon 97209 (503) 224-6145