Plans
John A. Stark, Architect Contact Person: John Stark PO Box 23215 Portland OR, 97239 503.544.6840 503.213.6181 jsbellaopus@msn.com DRAWING INDEX GENERAL G001 SHEET INDEX / SITE PLAN Meetinghouse Facilities Department Contact Person:Scott Robison, Project Manager 1271 Overlook Drive, Lake Oswego OR 97034 503.673.0118 801.718.1217 Cell robisonst@Idschurch.org A101 FLOOR PLAN A401 ENLARGED PLANS A501 ELEVATIONS / DETAILS MECHANICAL M1.1 DEMOLITION HVAC PLAN M1.2 DEMOLITION HVAC SECTIONS M2.1 HVAC FLOOR PLAN M2.2 HVAC SECTIONS CU PLANS M5.1 MECHANICAL DETAILS M6.1 MECHANICAL SCHEDULES ELECTRICAL E101 MAIN FLOOR POWER PLAN E102 ELECTRICAL SYMBOL LIST, ONE LINE DIAGRAM & SCHEDULES E103 PANEL SCHEDULES GENERAL NOTES 1. DRAWINGS SHALL NOT BE SCALED. 2. THE WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS AND RESTRICTIONS. 3. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS, RESTRICTIONS AND DIMENSIONS. 4. CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN PLANS AND EXISTING CONDITIONS AND SHALL NOT PROCEED UNTIL DISCREPANCIES ARE CLARIFIED BY ARCHITECT 5. CONTRACTOR SHALL PROTECT AREAS AFFECTED BY THE WORK FROM DAMAGE FROM WEATHER OR ADJACENT WORK 6. CONTRACTOR SHALL REPAIR ALL AREAS DAMAGED BY THE WORK AND/OR INADEQUATE PROTECTION AT NO ADDITIONAL EXPENSE TO OWNER. 7. CONTRACTOR SHALL DISPOSE OF WASTE AND DEBRIS GENERATED BY THE WORK OR CAUSED BY THE CONTRACTOR IN ACCORDANCE WITH APPLICABLE CODES, LAWS AND ORDINANCES. ELECTRICAL ENGINEEK MECHANICAL ENGINEER Athay & Associates, Inc.,Consulting Engineers Contact Person: Ron Athay, P.E. 411 NE 83rd Street, Vancouver WA 98665 360.574.0199 360.574.0209 FAX Paraclete PS, Inc., Mechanical Engineers Contact Person: Larry Grimes, P.E. 7510 N. E. Vancouver Mall Drive, Vancouver WA 98662 360.254.9234 360.254.7885 FAX GOVERNING CODES PROJECT DESIGN IS BASED ON THE CODES LISTED BELOW: 2010 OREGON STRUCTURAL SPECIALTY CODE OREGON STATE FIRE CODE OREGON STATE MECHANICAL CODE OREGON STATE PLUMBING CODE UJ v U 0 0 0 z BUILDING INFORMATION BUILDING USE: CHURCH MEETING HOUSE BUILDING AREA: 16,591.0 SQUARE FEET MAIN FLOOR : 16,311.0 SQUARE FEET SECOND FLOOR: 2,985.0 SQUARE FEET STANDARD SYMBOLS LEGEND W M Q �D O 70 .�<® o M0,M) o L0 0) IL Pitt LLEIs � y" o F_ A DETAIL DETAIL LETTER r.,.. 4 0 0 U) x, SHEET NUMBER f Rd 3Are_ SECTION SECTION LETTER SHEET NUMBER 0 5.5 , txTITLE SCALE -A. - W. ` ARE 2 ROOM ROOM ROOM NAME M ROOM NUMBER ROOM NUMBER SITE LOCATION t1 Atit�t`� Or 1/A6.3 ENLARGED PLAN p DOOR DESIGNATION WINDOW DESIGNATION 0,- W01 - N _ -ner ii sili� t A.ri,ta-i .r ELEVATION VfEW AB �'� (VIEW) 2.1 ELEVATION LETTER q - , Tigard SHEET NUMBER' -# ELEVATION+ ELEVATION (DATUM) 100'-0 p A VISUAL DISPLAY BOARDS VZ LOCATION MAP Paraclete PS, Inc., Mechanical Engineers Contact Person: Larry Grimes, P.E. 7510 N. E. Vancouver Mall Drive, Vancouver WA 98662 360.254.9234 360.254.7885 FAX GOVERNING CODES PROJECT DESIGN IS BASED ON THE CODES LISTED BELOW: 2010 OREGON STRUCTURAL SPECIALTY CODE OREGON STATE FIRE CODE OREGON STATE MECHANICAL CODE OREGON STATE PLUMBING CODE UJ v U 0 0 0 z BUILDING INFORMATION BUILDING USE: CHURCH MEETING HOUSE BUILDING AREA: 16,591.0 SQUARE FEET MAIN FLOOR : 16,311.0 SQUARE FEET SECOND FLOOR: 2,985.0 SQUARE FEET SITE PLAN (Not to Scale) S Q"310 a 54&7r s II Fp 1 ¢3 E fFe � I I 1 1 I 1 I F I F `{ I F y Y OF'rIGARD l ly Approved .............. j o: Follow .................. C { Attached ............LE.• - Date: A L 3 � proved plans, li Il be on job Site, APPROV�n P1,AN3 IM- DE UN-ATTACHCOt , S CIFICATION BOOK STRI CTURAL CALCS GEOTECH REPORT MISS: DOCUNIENT3 CE COPY Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: INDEX SHEET Sheet: UCEWE-D DL_ EC 10 2012 U)0� CI`T`Y OF TIGAR-O BUILDING DIVISION . ® LO N a) V N N W M Q �D O 70 .�<® o M0,M) o L0 0) IL Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: INDEX SHEET Sheet: U)0� H o CE) 0 . ® a) O EL z0 W ru^� �D L0 0) ® ® o F_ Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: INDEX SHEET Sheet: H o CE) 0 �D a A O EL H W ru^� �D 2- Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: INDEX SHEET Sheet: 0 2- 0 0 U) 0_ 0 M 0 Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: INDEX SHEET Sheet: 1/4 = 1'-0" SOUTHWEST ELEVATION 1/4" = 1'-0" PIPING INSTALLATION ACCESS AREA. REMOVE EXISTING WALL COVERING AND GYPSUM BOARD AS REQ'D TO INSTALL PIPING. PATCH AND REPAIR GYPSUM BOARD. REPLACE ENTIRE NORTH WALL WITH VINYL WALL COVERING PROVIDED BY OWNER. EXISTING BASE TO REMAIN NORTH INT WALL (N 1/4 of = 1'-0 WOOD FRAMED STRUCTURE W/ BRICK VENEER MECHANICAL PIPE BUILDING PENETRATION ZONE. (BELOW ENCLOSURE WALL) MECHANICAL ENCLOSURE WALL OUTLINE SHOWN DASHED. WOOD FRAMED STRUCTURE W/ BRICK VENEER MECHANICAL PIPE BUILDING PENETRATION ZONE. (BELOW ENCLOSURE WALL / ABOVE CHAIR RAIL) MECHANICAL ENCLOSURE WALL OUTLINE SHOWN DASHED. PAINT ENT INROOM I EXISTING. WOOD FR W/ BRICK MECHANIC PENETRA' (BELOW E / ABOVE MECHANIC WALL OU' DASHED. EAST INT WALL 1/4 of = 1 P-011 1/4 it = 1,— 0" PIPING INSTALLATION ACCESS AREA. CUT AND REMOVE EXISTING GYPSUM BOARDAS REQ'D TO INSTALL PIPING. PATCH AND REPAIR GYPSUM BOARD TO MATCH EXISTING. EXISTING CHAIR RAIL TO REMAIN EXISTING WALL COVERING TO REMAIN IY_ i0 NE. ENCL) 1.ly_��r��rCil�l 1/4 is = 1 ' — 0" PIPING INSTALLATION ACCESS AREA. CUT AND REMOVE EXISTING GYPSUM BOARD AS REQ'D TO INSTALL PIPING. PATCH AND """ A' """"" A BOARD TO EXISTING Cf TO REMAIN EXISTING W TO REMAIN EXISTING B) TO REMAIN PAINT ENTIRE EAST WALL IN ROOM TO MATCH r%ne%nLI WOOD FRAMED STRUCTURE W/ BRICK VENEER MECHANICAL PIPE BUILDING PENETRATION ZONE. (BELOW ENCLOSURE WALL / ABOVE CHAIR RAIL) MECHANICAL ENCLOSURE WALL OUTLINE SHOWN DASHED. EAST INT WALL (SE: ENCL) EXISTING MASONRY WALL TO REMAIN REMOVE EXISTING BRICK AND BLOCK AS SHOWN. "r EXISTING BRICK TO FI Ll_ I N RICK IS i ENCLOSURE PLAN CUT EXISTING RE -BAR AT CONCRETE AND GRIND SMOOTH CUT BACK METAL CAP, FORM AND SEAL EDGE AS REQUIRED TO MATCH EXISTING REMOVE EXISTING BRICK AND BLOCK AS SHOWN. RE -USE EXISTING BRICK AS REQ'D TO FILL IN WHERE FULL BRICK IS REMOVED. C--=JC-:1C-� EJC- C-�C-�C 11 �C �C - ry. F �C_D �C Ti 11 1 C-�C- -:]C- CJC-DC_ C �C �C_�C �C_ x o U U N CSC -DC -DC -DC _ U :1E N CL U w -�r�-:P - -IF_-_TF co - + II II II I -F-.+ N —7[=—�r—�r—� II o II II 1 _JL_JL_JL_J WINDOW I In n n r'' --n n I II cJLJLJL_ IH I II I �r-7r-7r -71 r IHI 1 II I II 11 II II III I 1 11 1 II II II II III I I III II II II II III II II 11 II I III II II II II II I I I I III II II II II II Ili I I III II II II II II III I I III II II II II II III l 11 I II II II II II II II II II I III JLJLJ JI- I H I 1 II F 1r --i r__ r__ H I Ilu u u u u ull ENCLOSURE ELEVATION ENCLOSURE WALL 1/2 If = 1'-O„ OPTION 2 -PAINT WEST WALL ABOVE CHAIR RAIL TO MATCH EXISTING ®� OPTION 2 NEW CHAIR RAIL TO MATCH EXISTING. EXISTING BASE TO REMAIN REMOVE EXISTING GATE AND POSTS. EXISTING WINDOW EXISTING BUILDING MASONRY WALL REMOVE EXISTING GATE AND POSTS. CUT POSTS AT CONCRETE. GRIND SMOOTH AND FILL VOIDS WITH GROUT. PIPING INSTALLATION ACCESS AREA. OPTION 2 -REMOVE WALL COVERING ABOVE NEW CHAIR RAIL. CUT AND REMOVE GYPSUM BOARD AS REQ'D TO INSTALL PIPING AND CONDUIT. PATCH AND REPAIR GYPSUM BOARD TO MATCH ADJACENT. INSTALL NEW CHAIR RAIL TO MATCH EXISTING. PIPING INSTALLATION ACCESS AREA. OPTION 1 -ROLL BACK WALL COVERING AT ACCESS AREA. CUT AND REMOVE GYPSUM AS REQ'D TO INSTALL PIPING.REPAIR GYPSUM BOARD, REINSTALL WALL COVERING. WEST INT WALL (S.W. ENCL Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: ELEVATIONS DETAILS Sheet: o ICU L. CO N x o U U N � _ U _Lco N N CL U w a co - + V -F-.+ N Pq o Q O 70 G L O 0 � W L_ O Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: ELEVATIONS DETAILS Sheet: o ICU V j CO N x o U U �J! � .® UA zp CL U w r1 'S� - + V co O Pq o Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: ELEVATIONS DETAILS Sheet: w O � Z x o U U �J! � N �:) O W UA CL U w � D � H � Pq w O Q Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: ELEVATIONS DETAILS Sheet: Q G L � W U n p N } r 0 O M � Y L C� G Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: ELEVATIONS DETAILS Sheet: A T F- XTEND ABOVE CHAIR RAIL i FOR REFRIGERANT PIPING j ENTRANCE INTO WALL CAVITY 1�N M E CH A N 1 CAL.E N CLOSURE U J 1/4 " = 1'-0" - - EXTEND ABOVE CHAIR j VERIFY BALANCE RAIL FOR REFRIGERANT j , , _________ ___ _________________-_-__________ ._.___ _________ — __ ____ _._....____ _ _ PIPING ENTRANCE INTO — - .___--- - --- .__ 210 CFM MANUAL DAMPER WALL CAVITY 3 16x19 SA ` - �+ 1x24 x24 RA i i I ; 14x241 RA4 + —4-- 6X6 ACCESS DO e' li +� 1Y2"VTR r " 24x1; SA MOTORIZED OSA -� r 1, i RUN NEW PIPE rr `? ° I cc -s rr �r 16x4 SA BEHINQ, i + DAMPER ENCLOSURE TO + !? i i j 8x10 BOTTOM OF I CI 121 #c 16 S + i �` EXISTING X"CD CU -10 4 CD 14x14 CU -9 ELECTRICAL BUS 2,_0„ DUCT. BEFORE CU -3 F F 4 .� — MAKING WALL PENETRATION FOR - u » + A 12x12 RA NEW REFRIGERANT i' 2. PIPING, VERIFY CR - i 12x12 SA - - 1 6 ---------------- 8x10 SA PENETRATION WILL .,.,., i— BE ABOVE CHAIR 2"W 10x10 SA TO QQ- RAIL. IF NOT, CD NOTIFY ARCHITECT MANUAL 8x8 MOTORIZED OUTSIDE AIR ACCESS OUTSIDE AIR „ REFRIGERANT S VII MECHANICAL ENCLOSURE DAMPER. � DOOR DAMPER. � ! ®PIPES " _ " VERIFY 1/4 1 —0 BALNCE AT I 200 CFM ; k CHAIR RAS ROTATE UNIT AND SECURE TO SLAB. — PROVIDE NEW REFRIGERANT PIPE APPURTENANCES, REMOVE TEMPORARY CAP AND CONNECT. USING EVACUATED REFRIGERANT, RECHARGE UNIT. PROVIDE ADDITIONAL REFRIGERANT AS NECESSARY PROVIDE NEW REFRIGERANT PIPE AND APPURTENANCES. RUN PIPES TO CONNECTION NEW PIPING ENCLOSURE POINTS IN ATTIC F err------- s �-- - ..��_. lull _ II CU -7 cu -s I I CU -8 3,_0„ I USING ACUATED REF ERANT, RECHARGE UNIT. PROVIDE ADDITIONAL — I REF IGERANT AS NECESSARY --- ---- - ---- - ----- — --------------- - EXTEND ABOVE CHAIR — j lI Ij jju RAL FOR REFRIGERANT PIPING ENTRANCE INTO WALL CAVITY i SW MECHANICAL ENCLOSURE 1/4 0 = 1'-0" REMOVE PORTION OF ENCLOSURE AS NECESSARY FOR NEW ENCLOSURE I ATTACHED TO EXISTING. EXTEND ABOVE CHAIR RAIL FOR REFRIGERANT PIPING ENTRANCE INTO WALL CAVITY 3 ----- - -_ -- -- -- - - --_ -—_� �_ i 0 INSTALLATION NOTES CU -2 1. AFTER CU -2 REFRIGERANT PIPES HAVE BEEN CU -8 i r — INSTALLED ON EXISTING SUPPORTS REMOVE I I I 2'-0" �2 I ENCLOSURE FROM STORAGE AND REINSTALL I i IIIA �� I LLQ ------------ JJ------- J 1,_9„ I MODIFY ENCLOSURE AS PROVIDE SHEET NECESSARY FOR NEW METAL OVER REFRIGERANT PIPES OPENING LEFT BY REMOVED PIPE , SE MECHANICAL ENCLOSURE ENCLOSURE 1/4 _ 1'-0" FIRE CAULK\-� + _ GALVANIZED IRON PIPE SLEEVE z i FIRE SEAL AROUND PIPE REFRIGERANT PIPE PENETRATION 1/2 0 = 1._o" Stamp: CO PRQ c 7820 OREGON 13,191 �C-3 CRY L. G��� EXP JUNE 30, 2013 ca 0 co U) Ca N N 0 ti C, _L N M 0 L) U) N Q Q z X 0 v 0 -0 o. Q 0 cc �L n Stamp: CO PRQ c 7820 OREGON 13,191 �C-3 CRY L. G��� EXP JUNE 30, 2013 I i� k2 4 # I 3 TO CU -6_.._ -__- - -_------_---_-- ____---------____ -. __ __-___- ...___ _..- TO ---------------- i CU -4 0 INSTALLATION NOTES 0 INSTALLATION NOTES 40- 1. 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE A 0 1 INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, o W GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. V 2. OFFSET REFRIGERANT PIPE IN WALL AS NECESSARY TO GO BETWEEN JOISTS. 2. OFFSET REFRIGERANT PIPE IN WALL AS NECESSARY TO GO BETWEEN JOISTS. M ECHANICAL SECTION ATF 6 M ECHANICAL SECTION ATF 4 0 1/4 = 1'-0" 1/4 1'- " REFRIGERANT PIPES O TO CU -3 O `— TO CC -3 i @ 16x24 SA 16x24 RA BEHIf'D MOTORIZED � CHAIR RAI- OUTSIDE AIR DAMPER. 16x16 SA CC -3 { s " Y O %cD y, 16x24 F 4 3 F s _.._........ _. ..... MANUAL II OUTSIDE AIR DAMPER. VERIFY BALANCE AT I 240 CFM 8x8 ACCESS DOOR Q INSTALLATION NOTES 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. 2. OFFSET REFRIGERANT PIPE N WALL AS NECESSARY TO GO BETWEEN JOISTS. MECHANICAL SECTION AT F-3 1/4 " = 1'-0" 12x16 SA A (D REFRIGERANT PIPES 2 CHAIR RAI,. Q INSTALLATION NOTES @ 16x24 SA'" 16x16 SA 1420 RA i 1420 SA f �CQ— ` CI %"CD 8X1 ; I rF 12x12 RA MOTORIZED-' `-8x8 MANUAL OUTSIDE AIR ACCESS i OUTSIDE AIR DAMPER. DOOR f DAMPER. _ VERIFY BALANCE AT 250 CFM 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE INSTALLATION OF REFRIGERANT PIKES. AFTER PIPES ARE INSTALLED AND TESTED, GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. 2. OFFSET REFRIGERANT PIPE W WALL AS NECESSARY TO GO BETWEEN JOISTS. 1 M ECH AN I CAL SECTION AT F-2 1/4 a = 1'-0" ca 0 U) Ca N -rte C: 0 ti .® o W Z0 0 L) U) 0 Q U �_ C) z �=C I i� k2 4 # I 3 TO CU -6_.._ -__- - -_------_---_-- ____---------____ -. __ __-___- ...___ _..- TO ---------------- i CU -4 0 INSTALLATION NOTES 0 INSTALLATION NOTES 40- 1. 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE A 0 1 INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, o W GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. V 2. OFFSET REFRIGERANT PIPE IN WALL AS NECESSARY TO GO BETWEEN JOISTS. 2. OFFSET REFRIGERANT PIPE IN WALL AS NECESSARY TO GO BETWEEN JOISTS. M ECHANICAL SECTION ATF 6 M ECHANICAL SECTION ATF 4 0 1/4 = 1'-0" 1/4 1'- " REFRIGERANT PIPES O TO CU -3 O `— TO CC -3 i @ 16x24 SA 16x24 RA BEHIf'D MOTORIZED � CHAIR RAI- OUTSIDE AIR DAMPER. 16x16 SA CC -3 { s " Y O %cD y, 16x24 F 4 3 F s _.._........ _. ..... MANUAL II OUTSIDE AIR DAMPER. VERIFY BALANCE AT I 240 CFM 8x8 ACCESS DOOR Q INSTALLATION NOTES 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE INSTALLATION OF REFRIGERANT PIPES. AFTER PIPES ARE INSTALLED AND TESTED, GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. 2. OFFSET REFRIGERANT PIPE N WALL AS NECESSARY TO GO BETWEEN JOISTS. MECHANICAL SECTION AT F-3 1/4 " = 1'-0" 12x16 SA A (D REFRIGERANT PIPES 2 CHAIR RAI,. Q INSTALLATION NOTES @ 16x24 SA'" 16x16 SA 1420 RA i 1420 SA f �CQ— ` CI %"CD 8X1 ; I rF 12x12 RA MOTORIZED-' `-8x8 MANUAL OUTSIDE AIR ACCESS i OUTSIDE AIR DAMPER. DOOR f DAMPER. _ VERIFY BALANCE AT 250 CFM 1. GENERAL CONTRACTOR TO REMOVE SHEET ROCK AS NECESSARY TO ENABLE INSTALLATION OF REFRIGERANT PIKES. AFTER PIPES ARE INSTALLED AND TESTED, GENERAL CONTRACTOR TO PATCH AND REPAIR SHEET ROCK. 2. OFFSET REFRIGERANT PIPE W WALL AS NECESSARY TO GO BETWEEN JOISTS. 1 M ECH AN I CAL SECTION AT F-2 1/4 a = 1'-0" Project Number: 539-1555-1201-0201 Plan Series: Property Number: �, 539-1555-1201-0201 Sheet Title: HVAC SECTIONS CU PLANS Lar Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER, WA. 95662 (360) 254-9234 E-MAIL- PARALG®COMCAST. NET Sheet:M2,2 C 0 �=C o. �L �L V I.L CL 0 1 Q 1 1 1 1 1 1 C) M cn CIOY Project Number: 539-1555-1201-0201 Plan Series: Property Number: �, 539-1555-1201-0201 Sheet Title: HVAC SECTIONS CU PLANS Lar Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER, WA. 95662 (360) 254-9234 E-MAIL- PARALG®COMCAST. NET Sheet:M2,2 THERMOS BULB 1+ MINIMUM THERMOSTATIC EXPANSION VALVE EQUALIZING LINE THERMOSTATIC BULB TO BE AS CLOSE TO COIL AS POSSIBLE NOT ALLOWED ON VERTICAL LINES CLAMP TOUCHDOWN II W/WOOD STUD SCREWS (2) SDS Ya'x1Y2" LONG WOOD SCREWS EACH END NOTES: STUD WRAP PIPE WITH (2) LAYERS OF SCOTCH 33 TAPE AT SUPPORT 1. TOUCHDOWN II ALLOWS MOVEMENT OF PVC PIPE 2. HANGER REQUIRED 6 FT ON CENTER 3. MAINTAIN Y8"/FT SLOPE CONDENSATE PIPE SUPPORT NO SCALE THERMAL EXPANSION VALVE CAN BE MOUNTED INSIDE COOLING COIL CABINET _`ERMAL BULB LOCATION UCTION LINE REFRIGERANT COIL CONNECTION DETAIL SCALE: NONE SUCTION LINE INSULATION CAULK WEATHERTIGHT (BOTH SIDES) PIPE ENCLOSURE NOTE LIQUID LINE SIMILAR REFRIGERANT PIPE WALL PENETRATION- &NO SCALE BOTTOM CHORD OF ROOF TRUSS OR I JOIST 5/8" GYPSUM BOARD INSULATION -)k DOUBLE SHEET/ METAL STRAP BACK OVER. 1" X 18 GAGE STRAP HANGERS AT 8'-0" SPACING. (1) #10 X 2" WOOD SCREWS ® EACH TRUSS CHORD (TYP.) #10 X 3/4" SELF TAPPING GALVANIZED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT MEMBERS.(TYPICAL) NO POP RIVETS ALLOWED TO DRAII SLOPE A 1 /4"/FT. z n 1 1/4" MIN. PENETRATION DUCT STRAP HANGER DETAIL SCALE: NONE IrA SINGLE THICKNESS TURNING VANES NOTE: SEE DETAIL L/P501 FOR SECONDARY DRAIN AT VERTICAL SYSTEMS i A nI II► nnr w vrn �nrr, I ----�N==�(�RFWFIi COOLING COIL CONDENSATE 1 DRAIN DETAIL NO SCALE f— SUCTION LINE SECURE REFRIGERANT i I5. INSULATION PIPINGTO SUPPORTS „ i i _ ,✓ WITH UNISTRUT PIPE'7 CLAMP OR EQUAL I I a at g I I � RUN INSULATION OF a• . SUCTION LINE THRU CLAMP ASSEMBLY 0– i f -------------------- -------------- / rOs F d�rl „ate 15/8//_1 t° I '1�t= P-3300 OR EQUAL � WALL WELD BOTH SIDES ; I z r (TYPICAL) I 4"x4"x1/ " ANGLE a` ANCHORED TO STRUCTURE WITH 1/20 HILTI HIT 150 NOTE: EXPANSION BOLT. LIQUID LINE SIMILAR REFRIGERANT PIPE SUPPORT AT WALL H SCALE: NONE 1" LONG MINIMI TRAILING EDGE � I � LEADING AND TRAILING EDGE TO BE PARALLEL WITH SIDE OF DUCT SINGLE THICKNESS TURNING VANE DETAIL NO SCALE 12"0. C FASTE (TYPI( IG FLEXIBLE CONNECTION (TYP.) SHUT–OFF VALVE. (TYP.) — FILTER DRYER SIGHT GLASS AIR FLOW SEE COIL CONNECTION DETAIL SLEEVE THRU WALL NEW FLEXIBLE CONNECTION (I NEW SIGHT GL/ TRAP,�S L g TYPICAL REFRIGERANT SCHEME, CU -8 NO SCALE SDS Y4"Ox2"LONG WOOD CEILING —1e SCREW & WASHER j JOIST ,,, (TYPICAL) ! __ _ .............�_..,_n _n,,............. CEILING. - -------------------- ----- – --------------------------- ---- ----- P1000 1% 0 e 0 0 UNISTRUT ® 4' O.C. REFRIGERANT NOTES: PIPES 1. ON REFRIGERANT PIPE PROVIDE TOUCHDOWN II STRUT CLAMP BY SIOUX CHIEF. INSULATION TO RUN CONTINUOUS THROUGH CLAMP. 1 REFRIGERANT PIPE SUPPORT _+�____ - 18 GAUGE GALVANIZED SHEET _.____ `'------i—��---- METAL PROTECTIVE COVER. f UNISTRUT PIPE CLAMP (TYP.) RUN FROM CONDENSING UNIT .I TO VERTICAL ENCLOSURE. COVER TO BE STANDING SEAM, i DUCTMATE, WARD OR TDC l I SEALED WATER TIGHT. SECURE TO UNISTRUT AT EACH SIDE. (n DRIP --J ( PAINT(2) COATS OF DARK ``'j EDGE BRONZ. SECURE REFRIGERANT PIPING TO >' ( SUPPORTS WITH "HYDRA–ZORB" ANGLE IRON UNISTRUT "CUSH–A–CLAMP" OR EQUAL P1026 TYPICAL OF 4 (TYPICAL) BUTT INSULATION OF SUCTION 1 15/8"" X 15/8" UNISTRUT CHANNEL LINE AGAINST CLAMP ASSEMBLY (GALVANIZED) (TYP.) L_.. ...... I .....'.... ...... .....r._._._.......-_._.._..........._...,_ _._....._ _ 1...........1...................r.._.._..._.. > TAPPER ANCHOR CONCRETE NOTES: 1. PROVIDE RAW EDGE PROTECTION AT CONDENSING UNIT, WALL AND OTHER EXPOSED EDGES EXCEPT DRIP EDGE. 2. PAINTED WELDED GALVANIZED SURFACES WITH TWO COATS OF GALVANIZED PAINT. 3. SECURE ANGLE TO PAD WITH Y4" RAWL STAINLESS STEEL TAPPER ANCHOR. 1X2" MINIMUM EMBEDMENT. EXTERIOR REFRIGERANT PIPE Sul PORT DETAIL PAD NO SCALE 12"O.C.MAX. IN DIRECTION r= AIR FLOW. F DUCT IS FABRICATED AUTOMATED COIL LINE -IIS DIMENSION MAY BE (CREASED TO 14" MAX.) DUCT LINER NOTE: ALL TRANSVERSE AND LONGITUDINAL EDGES OF LINER TO BE COATED WITH ADHESIVE. SHEET METAL DUCT NOTE: UNIT MAY BE SECURED THROUGH SECURE CONDENSING BOTTOM OF UNIT WITH (4) TAPPERS UNIT TO 1"x1"x18 AT CONTRACTORS OPTION GAU(;E ANGLE WITH CADMIUM PLATED VACUUM� CONDENSING UNIT SHEET METAL BREAKER TO � (NEW &EXISTING SCREW ATMOSPHERE C -r— PROTECTIVE COVER SECURE ANGLE TO RUN DRAIN � PAD WITH Y4" RAWL LINES SEPARATE INSULATED STAINLESS STEEL VIBRATION REFRIGERANT PIPE TAPPER ANCHOR. ISOLATION 1i2' 1X2" MINIMUM PADS EMBEDMENT, EXISTING TYPICAL CONCRETE 4 PLACES PAD NOTE: SIMILAR FOR RELOCATED CU -8 &CONDENSING UNIT NO SCALE 1 1/4" MIN. PENETRATION DUCT STRAP HANGER DETAIL SCALE: NONE IrA SINGLE THICKNESS TURNING VANES NOTE: SEE DETAIL L/P501 FOR SECONDARY DRAIN AT VERTICAL SYSTEMS i A nI II► nnr w vrn �nrr, I ----�N==�(�RFWFIi COOLING COIL CONDENSATE 1 DRAIN DETAIL NO SCALE f— SUCTION LINE SECURE REFRIGERANT i I5. INSULATION PIPINGTO SUPPORTS „ i i _ ,✓ WITH UNISTRUT PIPE'7 CLAMP OR EQUAL I I a at g I I � RUN INSULATION OF a• . SUCTION LINE THRU CLAMP ASSEMBLY 0– i f -------------------- -------------- / rOs F d�rl „ate 15/8//_1 t° I '1�t= P-3300 OR EQUAL � WALL WELD BOTH SIDES ; I z r (TYPICAL) I 4"x4"x1/ " ANGLE a` ANCHORED TO STRUCTURE WITH 1/20 HILTI HIT 150 NOTE: EXPANSION BOLT. LIQUID LINE SIMILAR REFRIGERANT PIPE SUPPORT AT WALL H SCALE: NONE 1" LONG MINIMI TRAILING EDGE � I � LEADING AND TRAILING EDGE TO BE PARALLEL WITH SIDE OF DUCT SINGLE THICKNESS TURNING VANE DETAIL NO SCALE 12"0. C FASTE (TYPI( IG FLEXIBLE CONNECTION (TYP.) SHUT–OFF VALVE. (TYP.) — FILTER DRYER SIGHT GLASS AIR FLOW SEE COIL CONNECTION DETAIL SLEEVE THRU WALL NEW FLEXIBLE CONNECTION (I NEW SIGHT GL/ TRAP,�S L g TYPICAL REFRIGERANT SCHEME, CU -8 NO SCALE SDS Y4"Ox2"LONG WOOD CEILING —1e SCREW & WASHER j JOIST ,,, (TYPICAL) ! __ _ .............�_..,_n _n,,............. CEILING. - -------------------- ----- – --------------------------- ---- ----- P1000 1% 0 e 0 0 UNISTRUT ® 4' O.C. REFRIGERANT NOTES: PIPES 1. ON REFRIGERANT PIPE PROVIDE TOUCHDOWN II STRUT CLAMP BY SIOUX CHIEF. INSULATION TO RUN CONTINUOUS THROUGH CLAMP. 1 REFRIGERANT PIPE SUPPORT _+�____ - 18 GAUGE GALVANIZED SHEET _.____ `'------i—��---- METAL PROTECTIVE COVER. f UNISTRUT PIPE CLAMP (TYP.) RUN FROM CONDENSING UNIT .I TO VERTICAL ENCLOSURE. COVER TO BE STANDING SEAM, i DUCTMATE, WARD OR TDC l I SEALED WATER TIGHT. SECURE TO UNISTRUT AT EACH SIDE. (n DRIP --J ( PAINT(2) COATS OF DARK ``'j EDGE BRONZ. SECURE REFRIGERANT PIPING TO >' ( SUPPORTS WITH "HYDRA–ZORB" ANGLE IRON UNISTRUT "CUSH–A–CLAMP" OR EQUAL P1026 TYPICAL OF 4 (TYPICAL) BUTT INSULATION OF SUCTION 1 15/8"" X 15/8" UNISTRUT CHANNEL LINE AGAINST CLAMP ASSEMBLY (GALVANIZED) (TYP.) L_.. ...... I .....'.... ...... .....r._._._.......-_._.._..........._...,_ _._....._ _ 1...........1...................r.._.._..._.. > TAPPER ANCHOR CONCRETE NOTES: 1. PROVIDE RAW EDGE PROTECTION AT CONDENSING UNIT, WALL AND OTHER EXPOSED EDGES EXCEPT DRIP EDGE. 2. PAINTED WELDED GALVANIZED SURFACES WITH TWO COATS OF GALVANIZED PAINT. 3. SECURE ANGLE TO PAD WITH Y4" RAWL STAINLESS STEEL TAPPER ANCHOR. 1X2" MINIMUM EMBEDMENT. EXTERIOR REFRIGERANT PIPE Sul PORT DETAIL PAD NO SCALE 12"O.C.MAX. IN DIRECTION r= AIR FLOW. F DUCT IS FABRICATED AUTOMATED COIL LINE -IIS DIMENSION MAY BE (CREASED TO 14" MAX.) DUCT LINER NOTE: ALL TRANSVERSE AND LONGITUDINAL EDGES OF LINER TO BE COATED WITH ADHESIVE. SHEET METAL DUCT NOT MORE THAN 2" FROM EDGE OF LINER. n DUCT LINER DETAIL SCALE: NONE NO SCALE SEE COIL DETAIL FILTER DRYER - SIGHT GLASS I L S SLEEVE THRU WALL VIBRATION ISOLATORS UNDERNEATH UNITS. TYPICAL REFRIGERANT SCHEME NO SCALE SLOPE AT 45• ANGLE UNISTRUT PIPE SUPPORT AT – CENTER OF RISER FLOOR WALL 5 TON AND UNDER 18 GAUGE SHEET METAL PROTECTIVE COVER AROUND REFRIGERATION & DRAIN LINES. ANCHOR TO EXISTING BRICK WALL. ENCLOSURE COVER TO BE STANDING SEAM, DUCTMATE, WARD OR TDC. SEALED WATER TIGHT. SEAL EDGES TO BUILDING WATER TIGHT. PAINT (2) COATS OF DARK BRONZE. -SEAL WEATHER TIGHT ALL AROUND PIPING ENCLOSURE NO SCALE NOTE: DO NOT RUN CONDENSATE DRAIN IN FRONT OF FURNACE. THIS WILL ALLOW ACCESS TO FURNACE COMPONENTS COOLING COIL • �k O f� N VACUUM� _ COOLING COIL BREAKER TO 1 � CONNECTIONS ATMOSPHERE C -r— U FURNACE RUN DRAIN � w LINES SEPARATE PRIMARY CONDENSATE NOT MORE THAN 2" FROM EDGE OF LINER. n DUCT LINER DETAIL SCALE: NONE NO SCALE SEE COIL DETAIL FILTER DRYER - SIGHT GLASS I L S SLEEVE THRU WALL VIBRATION ISOLATORS UNDERNEATH UNITS. TYPICAL REFRIGERANT SCHEME NO SCALE SLOPE AT 45• ANGLE UNISTRUT PIPE SUPPORT AT – CENTER OF RISER FLOOR WALL 5 TON AND UNDER 18 GAUGE SHEET METAL PROTECTIVE COVER AROUND REFRIGERATION & DRAIN LINES. ANCHOR TO EXISTING BRICK WALL. ENCLOSURE COVER TO BE STANDING SEAM, DUCTMATE, WARD OR TDC. SEALED WATER TIGHT. SEAL EDGES TO BUILDING WATER TIGHT. PAINT (2) COATS OF DARK BRONZE. -SEAL WEATHER TIGHT ALL AROUND PIPING ENCLOSURE NO SCALE NOTE: DO NOT RUN CONDENSATE DRAIN IN FRONT OF FURNACE. THIS WILL ALLOW ACCESS TO FURNACE COMPONENTS CONDENSATE CONDENSATE DRAIN TRAP DRAIN DROP l�t 3/ " 4 VERTICAL FURNACE CONDENSATE DRAIN TRAP DETAIL N 0 SCALE COOLING COIL • CABINET (TYPICAL) O f� N VACUUM� _ COOLING COIL BREAKER TO 1 � CONNECTIONS ATMOSPHERE C -r— U FURNACE RUN DRAIN � 0 LINES SEPARATE PRIMARY CONDENSATE TO TERMINATION DRAIN. INDICATED ON 1i2' DRAWINGS CONDENSATE CONDENSATE DRAIN TRAP DRAIN DROP l�t 3/ " 4 VERTICAL FURNACE CONDENSATE DRAIN TRAP DETAIL N 0 SCALE Stamp: PR�FFsLr I N 7820 �' 9 OREGON �g1 co EXP EXP JUNE 30, 2013 ICU p • Co N O f� N CD _ 1� �0) .® �— 1 z O a - W -r— U w wca � 0 ® 0 • Stamp: PR�FFsLr I N 7820 �' 9 OREGON �g1 co EXP EXP JUNE 30, 2013 Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: MECHANICAL DETAILS LarTy Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER. WA. 98662 (360) 254-9234 E-MAIL: PAR ALG®COMCAST. NET - M5.1 ICU p C- Co N O f� N CD _ 1� �0) .® �— D z O a - W -r— U w wca � LO 0) ® o� Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: MECHANICAL DETAILS LarTy Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER. WA. 98662 (360) 254-9234 E-MAIL: PAR ALG®COMCAST. NET - M5.1 O 4- .2 V Q a - W � w Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: MECHANICAL DETAILS LarTy Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER. WA. 98662 (360) 254-9234 E-MAIL: PAR ALG®COMCAST. NET - M5.1 0 H4- W LU a) ao 2 o c o L �o Project Number: 539-1555-1201-0201 Plan Series: Property Number: 539-1555-1201-0201 Sheet Title: MECHANICAL DETAILS LarTy Grimes Engineer 7510 N.E. VANCOUVER MALL DR SUITE 100 VANCOUVER. WA. 98662 (360) 254-9234 E-MAIL: PAR ALG®COMCAST. NET - M5.1 c" 3 .0 P 3 v L 0 A C HAY & ASSOCIATES, INC. P)�ooiysunM iaECTMw. 411 N.E. 83 8T. Vancouver, WA 98886 (380) a74-0198 (503) 286-2468 fax (380)674-0208 e-mail rathay®athayeng.00m , ENCL05URE E101 HEX NOTES: DISCONNECT AND REMOVE THE EXISTING CIRCUITRY FROM THE EXISTING CONDENSING UNIT. REMOVE THE EXISTING FUSED DISCONNECT SWITCH. ODISCONNECT THE EXISTING CIRCUITRY FROM THE EXISTING MECHANICAL UNIT AND REMOVE BACK TO THE SERVING ELECTRICAL PANEL. GENERAL NOTES: 1. SEE ALL DIVISION 22, 23, 25 DRAWINGS AND ME DRAWINGS FOR ADDITIONAL WORK BY DIVISION 26, 28. MAIN FLOOR POWER. 1 /8"=1'-0" PLAN `7 M x>- -1110- REWAY. NORTH ENCL05URE .;E NCE ONLY 0'T APPPOVED WITH THIS PERM. Stam S �6IStfRf f 10197 d � \'9LD D EXPIRES 12/31/13 ca o ® '® C 0) C .®a) z O W U) rn _ O Q c0 ~ v (D 4- 0 7 U L Q a co N CU U'l 0) *-J U) � r M ' V N O p x -0 N CU 00 j. O o Stam S �6IStfRf f 10197 d � \'9LD D EXPIRES 12/31/13 Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 MAIN FLOOR POWER PLAN E1 01 ca o ® '® o rn .®a) z O U) rn _ O Q c0 ~ 0 Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 MAIN FLOOR POWER PLAN E1 01 a U w � a. p N j. Z 0 t° C) � M Y r L ca Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 MAIN FLOOR POWER PLAN E1 01 i SOME SYMBOLS MAY NOT APPEAR ON DRAWINGS ELECTRICAL PANEL W/NAME BRANCH CIRCUIT IN WALL OR CEILING (TYPICAL TO NEW) BRANCH CIRCUIT EXPOSED h _______________________________________________________________ " ' ELECTRICAL PANEL EXISTING W/NAME _BRANCH CIRCUIT IN FLOOR _❑R_ EARTH_ P (TYPICAL T❑ REMOVE) _ BRANCH CIRCUIT EXISTING _ _ _ ,(E)„ ELECTRICAL PANEL EXISTING W/NAME UNDERGROUND PRIMARY (E) (TYPICAL TO REMAIN) POWER LINE - FIRE ALARM SIGNAL LIGHT AND HORN PWR PwR pa- PN_ waR PMR- pa- Prig- pa- Prig- Prig- PM - CIRCUIT (MINI HORN STROBE LOWER db) - ENR EMR EMR- EMR- ENR OAR- OAR OAR- EAR- EMR- ENR DM - TELEPHONE LINE �- FIRE ALARM SIGNAL LIGHT AND HORN WIREM❑LD C'pezzIo' sound ) _WN -%M VM _%M VN _w" _WN - VM _WN _w" - VM - VM - DATA LINE FD- FIRE ALARM PULL STATI❑N DARKER LINES INDICATE NEW �- FIRE ALARM HORN (E)LIGHTER LINES W/ (E) INDICATE EXISTING FIRE ALARM SIGNAL LIGHT .�- FIRE ALARM SIGNAL LIGHT AND H❑RN FIRE ALARM SMOKE DETECTOR HASH MARKS = # OF WIRES �D FIRE ALARM DUCT DETECTOR (NO HASH MARKS = 2 WIRES + 1 GRND) U FIRE ALARM HEAT DETECTOR � HASH MARKS = # OF WIRES W/ HARD WIRED GROUND A FIRE ALARM DETECTOR W/ A = AUX, CONTACTS � @ FIRE ALARM MAGNETIC DOOR HOLDER O LIGHTING FIXTURE -FLUORESCENT -RECESSED MOUNT � FIRE ALARM EQUIPMENT CONNECTION n� �FSD FIRE SMOKE DAMPER o LIGHTING FIXTURE -FLUORESCENT -SURFACE MOUNT T -o FIRE ALARM DETECTOR CARBON M❑N❑XIDE 0AB FIRE ALARM DETECTOR W/ AB = ALARM BASE O LIGHTING FIXTURE -FLUORESCENT -W/ CM CARBON MONOXIDE OUTLET EMERGENCY BATTERY INVERTER (- KEY PAD OUTLET LIGHTING FIXTURE -FLUORESCENT -ON v CARD READER L❑(ATI❑N / VERIFY PRIOR EMERGENCY CIRCUIT o- COMMUNICATIONS OUTLET \ �v� LIGHTING FIXTURE -EXISTING SHOWN DOTTED ®-- VOLUME CONTROL OUTLET L — — —'� (TYPICAL TO REMOVE) ©- CLOCK E LIGHTING FIXTURE -EXISTING SHOWN LIGHT LINED CLOCK -SPEAKER C❑MBINATI❑N (E) (TYPICAL T❑ REMAIN)- CLASS BELL �- CLASSROOM SOUND REINFORCEMENT SPEAKER LIGHTING FIXTURE -WALL MOUNT I/C SPEAKER ® LIGHTING FIXTURE -RECESSED PUSH BUTTON / CALL BACK SWITCH/WITH SPEAKER �® LIGHT/FAN FIXTURE -RECESSED PUSH BUTTON / CALL BACK SWITCH 0 LIGHTING FIXTURE -CEILING MOUNT o + PUSH BUTTON / START -STOP LIGHTING FIXTURE -CEILING MOUNT- DOOR BELL w/ STROBE per ADA LIGHTING FIXTURE -WALL SCONCE D (9 DATA OUTLET PROVIDE EACH LIGHTING FIXTURE -BRACKET MOUNT ' N'TD (p TELEPHONE/DATA OUTLET OUTLET WITH 1" C. P(P TO AGGE551BLE PRINTER OUTLET CEILING OR ATTIC. LIGHTING FIXTURE -EMERGENCY BATTERY PACK TVP TELEVISION OUTLET "N" = # OF DATA - M (P AUDI ❑ JACK OUTLET TELE GALES. IF LIGHTING FIXTURE -EMERGENCY BATTERY PACK AVP VIDE❑ OUTLET PROVIDE EACH POLE MOUNTED LIGHTING FIXTURE AS TYPED 7 TELEPHONE OUTLET OUTLET WITH 1 1/2" C �O REFER TO POLE BASE DETAIL PB TO ACCE551BLE INTERCOM OUTLET CEILING OR ATTIC, LIGHTING FIXTURE- SPECIAL REFER TO SPEC'S DISCONNECT W/FUSES ® LIGHTING FIXTURE -EXIT LIGHT [� DISCONNECT PROVIDE EACH To PHOTO ELECTRIC CELL OUTLET WITH 1" C. RELAY OCCUPANCY SENS❑R TO ACCE55I8LE LV TC TIME CLOCK CEILING OR ATTIC. TO ° RELAY OCCUPANCY SENSOR - 360° NL NIGHT LIGHT (8)OCCUPANCY SENSOR RELAY WP WEATHER PROOF DUPLEX CONVENIENCE OUTLET (DCO) WG WIRE GUARD S Q SAFETY TYPE DCO E. C. ELECTRICAL CONTRACTOR DCO 120V W/ GROUND FAULT PROTECTI❑N BKR CIRCUIT BREAKER DCO 120V W/ ARC FAULT PROTECTI❑N PEC PHOTO ELECTRIC CELL QUADPLEX CONVENIENCE OUTLET NEC NATIONAL ELECTRICAL CODE DEDICATED DCO (HARD WIRE GROUND) W/ WITH DEDICATED DCO (SPECIFIC EQUIPMENT) DC❑ DUPLEX C❑NVENIENCE ❑UTLET OUTLET 208V - AS NOTED CKT CIRCUIT TWO SECTI❑N ALUMINUM POWER/COMM POLE AFF ABOVE FINISH FLOOR *N-ONTD W/ QUAD OUTLET, 'N' TELE/DATA OUTLETS BFG BELOW FINISHED GRADE WHERE 'N' = THE NUMBER OF OUTLETS/CABLES, CIRCUIT BREAKER ENCLOSURE OO JUNTI❑N BOX St KI st = SHUNT TRIP O FLOOR MOUNTED OUTLET - AS NOTED K INSTALLED IN TOE KICK AREA ® C❑NNECTI❑N TO EQUIPMENT MOTOR DRIVEN DEVICE (E) ELECTRICAL DEVICE (TYPICAL TOREMAI e$e0 e = DEVICE OVER COUNTER A FIXTURE TYPE - LETTER UNDERLINED LIGHTING SWITCH - SINGLE POLE LIGHTING SWITCH - SECTION AS NOTED (DNUMBERED HEX SYMBOLS= REFER TO $3 LIGHTING SWITCH - THREE WAY MECHANICAL EQUIPMENT C❑NNECTI❑N SCHEDULE LIGHTING SWITCH - FOUR WAY O LETTERED HEX SYMBOLS, D LIGHTING SWITCH - DIMMER REFER TO SHEET NOTES LIGHTING SWITCH - KEYED # 06)F#1<0 # LIGHTING SWITCH - PILOT LIGHTED OTHER SYMBOL SHAPE _ LIGHTING SWITCH - MOMENTARY CONTACT REFER TO OTHER EQUIPMENT CONNECTION R SWITCH - MOTOR RATED SCHEDULES AS NEEDED, �]S OR tC SWITCH - WITH OCCUPANCY SENSOR NOTE: DOTTED SYMBOLS REFER TO DEVICES TO BE REMOVED. DASHED OR DOTTED CONDUIT LINES ON DEMO SHEETS ARE TO BE VERIFIED BEFORE MD SECURITY MOTION DETECTOR REMOVAL. THESE ARE USUALLY INDICATI❑NS OF SURFACE OR UNDERGROUND RAN CONDUIT, SECURITY CAMERA UE- EMERGENCY CALL STATION 1'C❑NDUIT FROM DEVICE BOX TO ACCESSIBLE CEILING SPACE OR AS NOTED. S DOOR POSITION SENSOR CONDUIT HOME RUN FROM DEVICE BOX TO PANEL AS CIRCUITED. EXISTING PRIMARY SERVICE. PAD MOUNT TRANSFORMER -EXISTING, (E)2 -4"C. ATHAY & ASSOCIATES, WC. & CONSULTM EM7MAL 411 N.E. 83 ST. Vancouver, WA 08886 (380) 674-0100 (603) 286-2468 fax (380)674-0200 •-mall rathay0athayen0.00m , Z_ 0 EXISTING METER. M CT ENCLOSURE 3w M CV (120/208V, 3P,4W 600A) �' LO (E)2 -4"C. (3-#350 & 1-#2/0 NEUTRAL)THW, CU EACH. -I-+ r 3 PHASE, 4 WIRE, 120/208 VOLTS EXISTING 4-1 M � [IE,JIMAIN PANEL M11 NCTRICAL 142. X-0 3P( (E)600A ? MAIN CKT BKR C:� 8 6 4 2 3 5 7 9 V m 3P 30A(E) 3P 60A(E) 3P 50A (E) 3P 150A(E) 3P 20OA(E) 3P 150A (E) 3P 90A(E) 3P 60A(E) 3P 10OA(E) ® �"" EXISTING Q Z StampG i P�F�r �� 10197 fd CJD C) + GROUND MAIN WATER � � � � SERVICE 4 m NEW 811X6" NEW 8"X6" ON EXISTING 611X611 ��RAINTIGHT RAINTIGHT LIJ 13, ti9 -L RAINTIGHT 04 cV CV r� WIREWAY. WIREWAY. a ASD D P��P dU- w WIREWAY. w w w w O )(N4(E�) P F P F P A B C )(N WP =EXPIRES 12/31/131, ELEC, 157 CUST, 113 CORR. 132 Y(EW)P7(EW) (E) 225 AMP 225 AMP 225AMP (E) 120/208V 120/208V 120/208V 30 4W 30 4W 30 4W EXIST' G EXIST' G EXIST' G 4 }C )C )C )C }C r) MAIN MAIN MAIN �41 9 5 10 v LUGS LUGS LUGS w QJ E103 HEX NOTES: 2 I--& 0 1 F PWPI F PWPFF-ZP EXISTING 611X6" CU WP F P F P EXISTING 6"X6" G)REINSTALL PROVIDE A NEW 8"X6" WEATHERPROOF WIREWAY. REMOVE AND CU (�(N) (E) (E) RAINTIGHT (N) LVE) (E) RAINTIGHT THE EXISTING FUSED DISCONNECT TO THE NEW -�+ p 0 WIREWAY. WIREWAY. WIREWAY. EXTEND AND CONNECT THE EXISTING CONSENSING'� _ UNIT FEEDER TO THE NEW WIREWAY. EXTEND THE EXISTING CONDENSING UNIT FEEDER TO THE REINSTALLED FUSED DISCONNECT z O )C )C )C)C )C )C AT THE NEW 8"X6" WEATHERPROOF WIREWAY LOCATION. PROVIDE FOR CONTINUATION OF POWER TO THE EXISTING CONDENSING UNIT. 7tfU toCU 3 9 10 2 8 1 WITH THE MECHAN A CAL CONTRACTOR TO INSTALLATION. F_ION. O c0 0 r SINGLE LINE DIAGRAM 1 NOT TO SCALE MECHANICAL EQUIPMENT SCHEDULE SYM DESCRIPTION CIRCUIT FEEDER *** VOLTS/0 DISCONNECT STARTER HP/WATTS FLA CU AIR COOLED CONDENSING UNIT M-5 1/2- C 3 #10 208/3 30AS/30AF-3P* NEMA 3R. INCLUDED - 14.6** 2 CU AIR COOLED CONDENSING UNIT M-4 1/2- C 3 #10 208/3 30AS/30AF-3P* NEMA 3R. INCLUDED - 14.6** 3 CU AIR COOLED CONDENSING UNIT M-8 1/2 of C 3 #12 208/3 30AS/20AF-3P* NEMA 3R. INCLUDED - 11.9** 4 CU AIR COOLED CONDENSING UNIT M-7 1/2 Is C 3 #10 208/3 30AS/30AF-3P* NEMA 3R. INCLUDED - 14.5** 6 *** PROVIDE CODE REQUIRED GROUND. GENERAL NOTES: ** MAXIMUM VALUES INDICATED. * FINAL BREAKER SIZE SHALL BE DETERMINED BY MANUFACTURERS 1. SEE ALL DIVISION 22, 23, 25 DRAWINGS AND ME DRAWINGS RECOMMENDATION FOR ACTUAL EQUIPMENT INSTALLED. FOR ADDITIONAL WORK BY DIVISION 26, 28. 2. COORDINATE (CONVEY) THE ELECTRICAL CONNECTION REQUIREMENTS AS SHOWN ON THE CONTRACT DOCUMENTS FOR THE HVAC UNITS WITH THE MECHANICAL CONTRACTOR. NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES FOR RESOLUTION PRIOR TO HVAC EQUIPMENT PURCHASE. PHASE LEG TERMINAL BLOCK FEEDER CONDUIT\ GROUNDING TERMINAL BLOCK 'X6' RAINTIGHT WIREWAY CONDENSING UNIT DETAIL SWITCH MOUNTING DETAIL nts APPLIES TO CU -2, CU -3, CU -4, CU -6 LOAD CALCULATION (PANEL M EXISTING DEMAND: 57.00 KW 57.00 KW/0.9 X 1.25= 79.16 KVA (219.88 AMPS) ADDED LOAD: 19.99 KVA (55.53 AMPS) TOTAL: 99.15 KVA (275.41 AMPS) CONDENSING UNIT DETAIL CONDUIT nts APPLIES TO CU -2, CU -3, CU -4, CU -6 FE NCE ONTLY NOT APPROVED WITH THIS PER Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 ELECTRICAL SYMBOL LIST, ONE LINE DIAGRAM, & ELECTRICAL SCHEDULES s= CL � U CL o N j O z 0 0 M Y L r (C� G Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 ELECTRICAL SYMBOL LIST, ONE LINE DIAGRAM, & ELECTRICAL SCHEDULES NEW WIREWAY M-4 LOCATION: SOUTHEAST ENCLOSURE NORTHEAST ENCLOSURE 208V 3 h 3w 208v 3PH 3w co 600A. BUSS 120/208v 3 h 4w NO T DESCRIPTION KVA NO T DESCRIPTION KVA DISC. 1 X (E)CU-1 3.99 T NO 1 X (N)CU-3 5.25 30AS/ A 20AF- 8 2 3 5 30AF- B A 4 5 5.25 3P(N) C B 6 7 X ECU -9 5.39 30AS/ Al8 11 8 9 25AF- B 12.70 10 11 14 3P(E) C 50AF- B 12 13 X ECU -10 4.21 30AS/ A 8 14 15 C 20AF- B 20 16 17 B 3P(E) C 23 18 19 Ic 24 A 12 20 21 26 27 B B 22 23 29 15 C 24 25 B A A 32 26 27 B B 35 28 29 29 36 C (N)WIREWAY M-7 30 31 38 39 A B 32 33 41 33 B B 34 35 34 35 C 36 37 36 S = SHUNT TRIP BREAKERS A LTG t 125% 38 39 * = EXISTING C.B. - ALL OTHERS NEW 39 B 1 40 41 40 LRGST 1 25% C I42 BLANK= C.B. POSITION LOAD CALCULATION OUTLETS 0.00 0.00 CIRCUIT BREAKER CODES 29 LIGHTING 0.00 S = SHUNT TRIP BREAKERS 0.00 LTG t 125% 0.00 * = EXISTING C.B. - ALL OTHERS NEW DEMAND OUTLETSt50% MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER M = MOTORS LRGST t 25% 0.00 BLANK= C.B. POSITION 0.00 OUTLETS 0.00 0.00 K = KITCHEN OUTLETS 0.00 0.00 DEDICATED OUTLETS 0.00 L = LIGHTING 0.00 DEMAND OUTLETS t50% 1 M = MOTORS HEAT KITCHEN 0.00 D = OUTLETS X = MISCELLANEOUS DEMAND KITCHEN 0.00 H = HEAT 21.94 HEAT 0.00 0.00 X = MISCELLANEOUS HEAT 0.00 0.00 MISCELLANEOUS 14.85 14.85 W = WELDERS MISCELLANEOUS 9.67 9.67 WELDERS TC = 0 DEDICATED OUTLETS WELDERS K = 0 DEMAND KITCHEN K = 0 DEMAND KITCHEN TC = 0 DEDICATED OUTLETS A K = 0 DEMAND KITCHEN (N)=NEW LOAD. (E)=EXISTING LOAD. 39 CONNECTED KVA 14.85 = 41.25 AMP CONNECTED KVAJ 21.94 DEMAND KVAI 1 14.85 = 41.251 AMP EXISTING WIREWAY M-5 LOCATION: SOUTHEAST ENCLOSURE NORTHWEST ENCLOSURE 208V 3 h 3w 208v 3 h 3w co 600A. BUSS 120/208v 3 h 4w NO T DESCRIPTION KVA DISC. KVA T NO 1 X (E)CU-1 3.99 30AS/ A 1 X ECU -5 2 3 A 20AF- 8 2 4 5 25AF- 3P(E) C A 6 7 X (N)CU-2 5.25 30AS/ Al8 C B 9 7 X ECU -9 30AF- BI 30AS/ 10 11 8 3P(N) Cl12 25AF- 13 X ECU -8 12.70 60AS/ A 11 14 15 C 50AF- B 12 16 17 30AS/ 3P(E) C 8 18 19 C A B 20 21 17 B 3P E 22 23 18 C Ic 24 25 12 A 21 26 27 B B 22 28 29 15 C 30 31 B A A 32 33 27 B 34 35 28 C 29 36 37 (N)WIREWAY M-7 A 31 38 39 A B 32 40 41 33 C B 42 LOAD CALCULATION 34 35 CIRCUIT BREAKER CODES LIGHTING 0.00 36 S = SHUNT TRIP BREAKERS A LTG t 125% 38 0.00 * = EXISTING C.B. - ALL OTHERS NEW 39 MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER 40 LRGST 1 25% C 0.00 BLANK= C.B. POSITION LOAD CALCULATION OUTLETS 0.00 0.00 K = KITCHEN 29 DEDICATED OUTLETS S = SHUNT TRIP BREAKERS 0.00 L = LIGHTING * = EXISTING C.B. - ALL OTHERS NEW DEMAND OUTLETSt50% MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER M = MOTORS LRGST t 25% 0.00 KITCHEN 0.00 OUTLETS 0.00 0.00 D = OUTLETS OUTLETS 0.00 0.00 DEMAND KITCHEN L = LIGHTING 0.00 H = HEAT M = MOTORS HEAT 0.00 0.00 X = MISCELLANEOUS DEMAND KITCHEN 0.00 MISCELLANEOUS 21.94 21.94 W = WELDERS HEAT 0.00 0.00 WELDERS W = WELDERS MISCELLANEOUS 9.67 9.67 TC - 0 DEDICATED OUTLETS TC = 0 DEDICATED OUTLETS WELDERS K = 0 DEMAND KITCHEN K = 0 DEMAND KITCHEN TC = 0 DEDICATED OUTLETS A K = 0 DEMAND KITCHEN (N)=NEW LOAD. (E)=EXISTING LOAD. 39 CONNECTED KVA14.99 N =NEW LOAD. (E)=EXISTING LOAD. 41.64 AMP CONNECTED KVAJ 21.94 = 60.941 AMP 26.861 AMP DEMAND KVAJ 1 21.94 = 60.941 AMP EXISTING WIREWAY M-6 LOCATION: LOCATION: NORTHWEST ENCLOSURE ELECTRICAL 142 208v 3 h 3w co 600A. BUSS 120/208v 3 h 4w MAIN 600 AMP BREAKER NO T DESCRIPTION KVA DISC. T DESCRIPTION T NO 1 X ECU -5 5.39 30AS/ A T NO 2 3 (E)PANEL 25AF- B A 4 5 2 3P(E) C B 6 7 X ECU -9 5.39 30AS/ A 4 8 9 25AF- B C 10 11 6 3P(E) C (E)PANEL 12 13 X ECU -10 4.21 30AS/ A 8 14 15 C 20AF- B B 16 17 10 3P E C1 18 19 Ic A 12 20 21 (E)WIREWAY M-5 21.94 B A 22 23 14 15 C 24 25 B 3P* A 16 26 27 B B 28 29 29 19 C (N)WIREWAY M-7 30 31 30 31 A 20 32 33 32 33 B B 34 35 34 35 C 36 37 36 37 A 24 38 39 38 39 B A 40 41 40 41 C L- 42 LOAD CALCULATION 42 LOAD CALCULATION _ CIRCUIT BREAKER CODES 29 LIGHTING 0.00 S = SHUNT TRIP BREAKERS LIGHTING 0.00 LTG 1 125% 0.00 * = EXISTING C.B. - ALL OTHERS NEW LTG 1 125% 0.00 MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER MOTORS 0.00 0.00 LRGST t 25% 0.00 BLANK= C.B. POSITION LRGST t 25% 0.00 OUTLETS 0.00 0.00 K = KITCHEN OUTLETS 0.00 0.00 DEDICATED OUTLETS 0.00 L = LIGHTING DEDICATED OUTLETS 0.00 DEMAND OUTLETS' 50% M = MOTORS DEMAND OUTLETSt50% KITCHEN 0.00 D = OUTLETS KITCHEN 0.00 DEMAND KITCHEN 0.00 H = HEAT DEMAND KITCHEN 0.00 HEAT 0.00 0.00 X = MISCELLANEOUS HEAT 0.00 0.00 MISCELLANEOUS 14.99 14.99 W = WELDERS MISCELLANEOUS 9.67 9.67 WELDERS TC = 0 DEDICATED OUTLETS WELDERS K = 0 DEMAND KITCHEN TC = 0 DEDICATED OUTLETS A K = 0 DEMAND KITCHEN (N)=NEW LOAD. (E)=EXISTING LOAD. 39 CONNECTED KVA14.99 = 41.64 AMP CONNECTED KVAJ 9.67 DEMAND KVA 14.99 = 41.641 AMP NEW WIREWAY M-7 LOCATION: LOCATION: SOUTHWEST ENCLOSURE ELECTRICAL 142 208v 3 h 3w co 600A. BUSS 120/208v 3 h 4w MAIN 600 AMP BREAKER NO I T I DESCRIPTION KVA DISC. T DESCRIPTION TNO 1 X (N)CU-6 5.21 30AS/ A T NO 2 3 (E)PANEL 30AF- 8 A 4 5 2 3P(E) C B 6 7 X TE7CU-8 12.70 60AS/ Al8 4 8 9 50AF- 8 C 10 11 6 3P(E) C (E)PANEL 12 13 A 50A 14.85 A 8 14 15 C N B B 16 17 10 11 Ic 18 19 Ic A 12 20 21 (E)WIREWAY M-5 21.94 8 A 22 23 14 15 C 24 25 B 3P* A 16 26 27 1B B 28 29 29 19 C (N)WIREWAY M-7 30 31 30 31 A 20 32 33 32 33 B B 34 35 34 35 C 36 37 36 37 A 24 38 39 38 39 8 A 40 41 40 41 C L- 42 LOAD CALCULATION 42 LOAD CALCULATION CIRCUIT BREAKER CODES 29 LIGHTING 0.00 S = SHUNT TRIP BREAKERS LIGHTING 0.00 LTG t 125% 0.00 * = EXISTING C.B. - ALL OTHERS NEW LTG 1 125% 0.00 MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER MOTORS 0.00 0.00 LRGST t 25% 0.00 BLANK= C.B. POSITION LRGST t 25% 0.00 OUTLETS 0.00 0.00 K = KITCHEN OUTLETS 0.00 0.00 DEDICATED OUTLETS 0.00 L = LIGHTING DEDICATED OUTLETS 0.00 DEMAND OUTLETSt50% M = MOTORS DEMAND OUTLETSt50% KITCHEN 0.00 D = OUTLETS KITCHEN 0.00 DEMAND KITCHEN 0.00 H = HEAT DEMAND KITCHEN 0.00 HEAT 0.00 0.00 X = MISCELLANEOUS HEAT 0.00 0.00 MISCELLANEOUS 17.91 17.91 W = WELDERS MISCELLANEOUS 9.67 9.67 WELDERS TC = 0 DEDICATED OUTLETS WELDERS K = 0 DEMAND KITCHEN TC = 0 DEDICATED OUTLETS A K = 0 DEMAND KITCHEN N =NEW LOAD. (E)=EXISTING LOAD. 39 CONNECTED KVA 17.91 = 49.75 AMP CONNECTED KVAJ 9.67 DEMAND KVA 1 17.91 = 49.75 AMP ATHAY & ASSOCIATES, INC. IXTNo aECTFIca. 411 N.E. 83 ST. Vancouver, WA 08885 (380) 574-0100 (503) 286-2468 fax (380)674-0200 s -mall rathay0athayonaoom NEW WIREWAY M-8 LOCATION: LOCATION: NORTH ENCLOSURE ELECTRICAL 142 208v 3 h 3w co 600A. BUSS 120/208v 3 h 4w MAIN 600 AMP BREAKER NO T DESCRIPTION KVA DISC. T DESCRIPTION T NO 1 X (N)CU-4 4.28 30AS/ A T NO 2 3 (E)PANEL 20AF- B A 4 5 2 3P(N) C B 6 7 X ECU -11 5.39 30AS/ A 4 8 9 25AF- B C 10 11 6 3P(E) C (E)PANEL 12 13 A 50A 14.85 A 8 14 15 C N B B 16 17 10 11 C 18 19 121 Ic Al20 12 13 r (E)WIREWAY M-5 21.94 B A 22 23 14 15 C 24 25 B 3P* A 16 26 27 B 28 29 19 (N)WIREWAY M-7 C 60A 30 31 (N)WIREWAY M-8 20 A 32 33 3P* B B 34 35 C M 36 37 24 A 38 39 100A A B 40 41 L- C 3P* 42 LOAD CALCULATION 28 29 CIRCUIT BREAKER CODES LIGHTING 0.00 S = SHUNT TRIP BREAKERS C 1 LTG 1 125% 0.00 * = EXISTING C.B. - ALL OTHERS NEW 30 MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER LRGST t 25% 0.00 BLANK= C.B. POSITION Al32 OUTLETS 0.00 0.00 K = KITCHEN DEDICATED OUTLETS 0.00 L = LIGHTING DEMAND OUTLETSt50% M = MOTORS B KITCHEN 0.00 D = OUTLETS 34 DEMAND KITCHEN 0.00 H = HEAT HEAT 0.00 0.00 X = MISCELLANEOUS C MISCELLANEOUS 9.67 9.67 W = WELDERS 36 WELDERS TC = 0 DEDICATED OUTLETS A K = 0 DEMAND KITCHEN 38 39 (N)=NEW LOAD. (E)=EXISTING LOAD. B CONNECTED KVAJ 9.67 40 1= 26.861 AMP DEMAND KVA 9.67 = 26.86 AMP MAIN SWITCH BOARD M LOCATION: '® ELECTRICAL 142 1 -:D co 600A. BUSS 120/208v 3 h 4w MAIN 600 AMP BREAKER r� V J < NO T DESCRIPTION KVA BKR BKR KVA DESCRIPTION T NO 1 (E)PANEL 0.00 200A A 150A 0.00 E PANEL 2 3 B 3P* B 3P* A 4 5 C 6 7 (E)PANEL 0.00 150A A 50A 14.85 (E)WIREWAY M-4 8 9 C N 3P* B 3P* 10 11 1 } Ic 12 13 r (E)WIREWAY M-5 21.94 90A A 60A 14.99 (E)WIREWAY M-6 14 15 3P* B 3P* 16 17 C 18 19 (N)WIREWAY M-7 17.91 60A A 30A 9.67 (N)WIREWAY M-8 20 21 3P* B 3P* 22 23 M C 24 25 SPARE C.B. 0.00 100A A 26 27 L- 3P* B 28 29 C 1 30 31 Al32 33 B 34 35 C 36 37 A 38 39 B 40 41 CI 42 LOAD CALCULATION CIRCUIT BREAKER CODES LIGHTING 0.00 S = SHUNT TRIP BREAKERS LTG t 125% 0.00 * = EXISTING G.B. - ALL OTHERS NEW MOTORS 0.00 0.00 SPARE= CIRCUIT BREAKER LRGST 1 25% 0.00 BLANK= C.B. POSITION OUTLETS 0.00 0.00 K = KITCHEN DEDICATED OUTLETS 0.00 L = LIGHTING DEMAND OUTLETS* -50% M = MOTORS KITCHEN 0.00 D = OUTLETS DEMAND KITCHEN 0.00 H = HEAT HEAT 0.00 0.00 X = MISCELLANEOUS MISCELLANEOUS 79.36 79.36 W = WELDERS TC = DEDICATED OUTLETS K = 2 IDEMAND KITCHEN LOAD CONNECTED KVA 79.36 = 220.44 AMP EXISTING MAIN SWITCHBOARD. (N)= NEW LOAD. E)= EXISTING LOAD. DEMAND KVA 79.36 = 220.44 AMP M-TERENCE ONLY NOT APPROVED WITH TMS PERMIT EN Stam PF 10197Rfda l ALD D P��P EXPIRES 12/31/13 co O Co 0) '® O 0) 1 -:D co Z o LO 0) r� V J < r 0 • � N CL O 1- 00 - Stam PF 10197Rfda l ALD D P��P EXPIRES 12/31/13 Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 PANEL SCHEDULES co O Co '® O 0) 1 -:D c Z o v cc O < LO c0 ~ 0 O Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 PANEL SCHEDULES c 0 CL LU a - N } r � O N O M L- Project Number: 539-1555-1201-0201 Plan Series: Custom Property Number: 539-1555-1201-0201 PANEL SCHEDULES