Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
c X in oC 2 Lo �L0 c m c 0 0 m Lo LA c W w 0 .. o Z� m � aLL- Lu U � E N a H chi FA Orn O 0 L - - ^� � NC7M g rr^^ d 0 Lu Lu 00 U) CO OXY= S O cMD-jCnin w t. a> m a� N 0 v s " I 1"A m 0 a� m m 0 m a� a� m s w a m m SITE TA L L ER DRAWING INDEX E DWG# DESCRIPTION LINLCOLN 1 CA'F�kITOL ELECTRIC a FA-001 COVER SHEETca N rK"NFA-002 GENERAk�L INFORMATION 10300SWGREENhIBURG01NEMAX '' IFA-101L DEVICE 7'LACEMENT PLAN & CALCULATIONS d - - .O FA-701 WIRING TYPICALS G TIG.ApKmk 0 97223 rFmk 0 RT LAI 14 0 97220a E 971 m506m3O720 0 L I CL DAP4 WILSON m 3 t L) t 3 a� 'o a m s 0 c 0 m 0 a� .o n ami rn `I m *ONWNER ut SHORENSTEIN REALTY SER"V'FICES 10220 SW GREENBUrK�kG . RD ca. � c PORTLAN 0 97223m 0 a, c m " 0 U) k a� .n 0 m c 0 co o c Of m N 7 - - N V O C O L.!_1 CV W L r / L a p C C cu U U Cn ® c 0 0p vp < z o CD c cc o C .a o O - - is N � ,,,,11 .O WW U .Q 'W^^ cu vI - - - - _ E VJ _ U) (O - - w � 42 C ig CIT17 Or" GAS Q Approved ���- a, . _ rrw! rrw.r.r♦lior�rnlrrrrrtrrrr (— Conditionally Apps-owed.............. Q JJII U ^ See ,eero: oI Ioev. o CC r.rlr.rrrrr rar..r. � C - �/� /�{} �a O L1CY, 4...i'' wwr 1w� O - .wwrrrrlM! r .6305 SW ROSEWOODST, SUITE A . \l� - _ M N - fieri Ntxber: �� o o cc LAKE OSWEGO, OR 97035 Address: � w M a� N 1 cv 'pproVod pt n a W PHONE: 503-683-9000 5 �: T z DRAWN BY: R. HERMANT Am SERVICE: 503-683-9001 CHECKED BY: J. JOHNSON Q FAX 503-675-6521 OFFICE COPS ISSUE DATE: 5/28/13 -' JOB#: o PROJECT#: 448:970977701 SIMPLEXGRINNELL© 2013 � a _ TM SYSTEM: FIRE ALARM SYSTEM rArAoftA Ift [folarterA. i cu g) SHEET: N m a �C SALES REPRESEN TA TI VE DRA WINGS PREPARE® S Y COVER SHEETcu c E 'a m BRYAN ADAMS JEFFRY JCO cn N m.p co w E W 503-683-9000NICET LEVEL 111 #121846 U _ - uj1 FA-001C> Z 1O X - - - - -Q y M - O � 0 E R `m X SYSTEM DESCRIPTION SCOPE OE WORD SYMBOL KEY m GENERAL NOTES or... q rn� o co OCCUPANCY TYPE: B BUSINESS GROUP 6i 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF o CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGESSPRINKLER PROTECTION: BUILDING IS NOT SPRINKLED I /� ® ¢a U SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. FIRE ALARM SYMBOLS LEGEND p 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR v E DEVIATIONS TO IMPAIR THE SCHEDULE.ONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT SE°OWN EXISTING ALARM SYSTEM: PROVIDE NEW DEVICES AND RELOCATE EXISTING DEVICES AS SYMBOL DESCRIPTION MODEL BACKBOX 2a 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING o DESIGN IS FOR THE NOTIFICATION OF LINCOLN 1 SUITE 20. NAC EXTENDER PANEL ooM AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY S E 2 AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. NAC DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL o 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR ALL NEW WIRING TO BE CLASS B. W / 6.2AH BATTERY SET SIMPLEX 2081-9272 oujc m INSTALLATION. o L N 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE SMOKE SENSOR / BASE SIMPLEX 4098-9714 i W > ® SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP � N BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS FIRE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTORS RESPONSIBILITY TO ca o v ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. cu 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO � MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 3 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. cn 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. = 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO RI RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER -� ca PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF a ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. DH DOOR HOLDER BY OTHERS s 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. FIRE ALARM APPLICABLE CODES C.X,, STANDARDS ® / / N 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). C CEILING MOUNT MULTI-CANDELA V 0 WHITE SIMPLEX 4906-9104 HANDY BOX 1 1 2 DEEP 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE # =CANDELA RATING 2 ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE CEILING MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9130 4" SQUARE BOX 1 1/2" DEEP FPLP. C # =CANDELA RATING 0 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED INEn OREGON FIRE CODE, 2010 EDITION VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 _o 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET OREGON MECHANICAL SPECIALTY CODE, 2010 EDITION END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 ' LOCATIONS. EOLR SUPPLIED BY OTHERS Z END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 AR cu -17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH OREGON ELECTRICAL SPECIALTY CODE, 2010 EDITION END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 cn NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. AnU 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. NATIONAL FIRE ALARM CODE (NFPA 72), 2010 EDITION NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. C 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING c a CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO L STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. c -o a :Mns o 0 a E 0 JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. N CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. o co 0_ cn co RISER DIAGRAM a WIRE SCHEDULE ABBREVIATIONS LEGEND . U 3 v a •o AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM N RL = RELOCATED DEVICE N/A = NOT APPLICABLE o FIRE ALARM WIRE LIST (POWER LIMITED) RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER a WP = WEATHERPROOF NDU = NETWORK DISPLAY UNIT (RL) V VISUAL SIGNAL CIRCUIT - 2 CONDUCTOR 14 AWG SOLID XP EXPLOSION PROOF NEC = NATIONAL ELECTRICAL CODE GENERAL NOTES: V NON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP NFPA - NATIONAL FIRE PROTECTION ASSOCIATION N5 EOLR cn �2) ( )AREAE0.0356 SQ. INCH EA#10 0097 SQ(RED/BLACK) CKEACH AREAE0.0330 SQ. INCH 1. O ICEUANTITY AND LOCATION. SEE FLOOR PLAN C C C C Q _ _ ( _ AFF = ABOVE FINISHED FLOOR NIC = NOT IN CONTRACT ********** REFER TO SIGNAL CIRCUIT DISTANCE HART ********** AHJ = AUTHORITY HAVING JURISDICTION NPU NETWORK PROCESSING UNIT Q V U ` ALM = ALARM NTS = NOT TO SCALE 2. ALL WIRING SHALL COMPLY WITH NFPA 70 ARTICLE N6 EOLR cu CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA �_m 0 1/2" 0.12 SQ INCH 1-1 4" 0.60 SQ INCH * POWER LIMITED SYSTEMS. C C C C * ANN = ANNUNCIATOR PAP = .PRE-ACTION PANEL 760, EOLR V 3 4" .0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * BMS = BUILDING MANAGEMENT SYSTEM SCC = STATUS COMMAND CENTER NAC2 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 1/ 0.34 SQ INCH * 2" / 1.34 SQ INCH * CBC = CALIFORNIA BUILDING CODE SLC = SIGNALING LINE CIRCUIT O * 40% FILL 2005 N.E.C. CD = (eg. 15CD) CANDELA SMK = SMOKE N7 SPARE - CONTACT YOUR LOCAL SIMPLEXGRINNELL OFFICE CSFM = CALIFORNIA STATE FIRE MARSHALL SUPV SUPERVISORY �^ DET = DETECTOR TAC = TRUEALERT ADDRESSABLE CONTROLLER v J o FOR ANY CABLE SUBSTITUTIONS DGP = DATA GATHERING PANEL TRBL TROUBLE c KEYED NOTES N8 SPARE E EOL = END OF LINE TS = TAMPER SWITCH 0 EPO = EMERGENCY POWER OFF TYP = TYPICAL O RELOCATE EXISTING END OF LINE RESISTOR. 120VAC _� co FACP = FIRE ALARM CONTROL PANEL UON UNLESS OTHERWISE NOTED cn FATC = FIRE ALARM TERMINAL CABINET VCC = VOICE COMMAND CENTER FBO = FURNISHED BY OTHERS VT = VALVE TAMPER 2ND FLOOR100 in FCC = FIRE COMMAND CENTER WF = WATER FLOW FAA = FIRE ALARM ANNUNCIATOR W = (eg. 1/2W) WATT r FTR = FIRE ALARM TRANSPONDER W/ = WITH � cn FSD = FIRE SMOKE DAMPER W/O = WITH OUT 0 z N c L LJ CV W � L T VJ V I •C DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION ® 0 U U J U) to O - 0 0 zoo- o JJ v-- CONTROL - I- o CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL 0 0 cu E o NOTIFICATION APPLIANCE CIRCUIT DEVICE DESIGNATOR Q� �� �w �,��' �Q��P� ��\O� 0�5 �,`PJQ��Q��a�Je ��0� �GP� �J5 I r N2- 2_ 1 N NOTIFICATION DEVICE oo PJ �o PJ oo PJ P P�. P� P 5 �. o �� tib, ru JPF,JPS P�JPS J. SYSTEM INPUTS A B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH REMARKS o • • • • • • • • • • • • 1 0 1 SMOKE SENSOR DETECTOR _ w 2 MANUAL PULL STATION 2 3 DUCT SENSOR DETECTOR . . . . . . . • • 3 } 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • 4 °D 5 ELEVATOR LOBBY SMOKE DETECTORS EXC. MAIN FLR. • • • • • • • • • • cn 0 5 Lu 6 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • • • • • • 6 co 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • 7 8 ELEVATOR SHAFT HEAT DETECTOR • • . • • . . g o J 9 ELEVATOR SHAFT SMOKE DETECTOR • • • • • • • • • 9 10 ELEVATOR POWER MONITOR • • • • 10 o 11 FIRE ALARM AC POWER FAILURE • • • • • • • 11 Lu p 12 FIRE ALARM SYSTEM LOW BATTERY • • • 12 o 13 OPEN CIRCUIT OR GROUND FAULT • • • 13 -� 14 CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT • 14 15 15 0 o 16 16 N 17 17 0 a 18 18 Lu 19 19 ca N 20 20 cn ch 21 21 2 M 22 22 c=n 0 23 23 w N 2412410 25 25 In 26 26 Lu 27 27 z 28 281DRAWN BY: R. HERMANT 0 a 29 291CHECKED BY: J.JOHNSON 30 30 ISSUE DATE: 5/28/13 31 31 JOB#: 0 32 3 PROJECT#: 448:970977701 A B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z FA AB AC AD AE AF AG AH SIMPLEXGRINNELL© 2013 E _o SYSTEM: FIRE ALARM SYSTEM a � U SHEET: •� o GENERAL INFORMATIONco � E cu co m N w E U W - - Q Co FA-002 z z � M a E cm X> �iin GENERAL NOTES ®\ C>LO 00 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE 0 0 L0 LO c w z o W0 W I KEYED NOTES: mo,' "' a ®\ cf)CD� ORELOCATE EXISTING EOL RESISTOR. o o� N 2 CHANGE TO 15 CANDELA. N(Do 0 3 CHANGE TO 30 CANDELA. F. w ca 02 �W> _ CO oYa W vJ o rn ti m NAC-2 BATTERY CALCULATIONS NAC-2 NOTIFICATION APPLIANCE CIRCUIT SCHEDULE 3 Standby Total Alarm Total PLAN CKT PANEL CIRCUIT DESCRIPTION # OF DEVICES CURRENT (A) N Description Qt Standby N5 NAC 1 2ND FLOOR WEST NOTIFICATION 12 1.677 L Module P Y Current Y Current Alarm y Panel Equipment N6 NAC 2 2ND FLOOR WEST NOTIFICATION 11 1.451 N7 NAC 3 SPARE 0 0.000 M 4009-9201 4009 IDNET NAC EXTENDER, 120 VAC 1 0.085 0.085 0.185 0.185 N8 NAC 4 ISPARE 0 0.000 Total Panel Stb , Y0.085 Total Panel Alarm 0.185 Notification Appliance Circuits From NAC Schedule 3.128 0 Total Periph StbY 0.000 Total Periph Alarm 3.128 Total Standby Amps 0.085 Total Alarm Amps 3.313 VOLTAGE DROP CALCULATIONS - N5 WIRE GAUGE 14 AWG Standb 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS Y Alarm STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC Q Qty Current CurrentMINIMUM DEVICE VOLTAGE 16 VDC Control Panel Power (Master Power Supply) 0.085 0.185 PERCENTAGE VOLTAGE DROP 12% Power For External Peripheral Devices _ 0.000 3.128 DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT Z 0.085 <-- Totals --> 3.313 NUMBER NUMBER FT CURRENT A CURRENT A DROP V DEVICE V Standby Time = 24 Hrs 1.951 Standby Ah N5-1 4906-9130 15 24 0.086 1.677 0.25 20.15 E Alarm Time = 5 Mins. 0.264 Alarm Ah N5-2 4906-9104 15 36 0.075 1.591 0.35 19.80 N C; Battery Supplied 2081-9272 6.2AH 3.464 Total Ah N5-3 4906-9130 110 45 0.320 1.516 0.42 19.38 N5-4 4906-9104 15 41 0.075 1.196 0.30 19.08 X N5-5 4906-9130 75 31 0.250 1.121 0.21 18.87 N5-6 4906-9104 15 40 0.075 0.871 0.21 18.65 N5-7 4906-9130 75 46 0.250 0.796 0.22 18.43 N5-8 4906-9130 30 53 0.132 0.546 0.18 18.25 N5-9 4906-9130 30 58 0.132 0.414 0.15 18.10 N5-10 4906-9130 30 32 0.132 0.282 0.06 18.05 N5-11 4906-9104 15 24 0.075 0.150 0.02 18.03 0 N5-12 4906-9104 15 42 0.075 0.075 0.02 18.01 Mn 0 0 E 0 0 _ VOLTAGE DROP CALCULATIONS - N6 WIRE GAUGE 14 AWG 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS a STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 20.4 VDC 3 MINIMUM DEVICE VOLTAGE 16 VDC PERCENTAGE VOLTAGE DROP 10% o DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT -o NUMBER NUMBER FT CURRENT A CURRENT A DROP V DEVICE V N6-1 4906-9104 15 31 0.075 1.451 0.28 20.12 N6-2 4906-9130 15 45 0.086 1.376 0.38 19.74 0 N6-3 4906-9130 75 35 0.250 1.290 0.28 19.47 N6-4 4906-9104 75 63 0.233 1.040 0.40 19.06 N N6-5 4906-9104 15 41 0.075 0.807 0.20 18.86 2- N6-6 N6-6 4906-9130 30 36 0.132 0.732 0.16 18.70 N6-7 4906-9104 15 40 0.075 0.600 0.15 18.55 0 N6-8 4906-9130 75 49 0.250 0.525 0.16 18.39 N6-9 4906-9104 15 34 0.075 0.275 0.06 18.34 N6-10 4906-9104 1 30 1 41 0.125 0.200 0.05 18.29 M N6-11 1 4906-9104 15 25 0.075 1 0.075 1 0.01 1 18.27 - T C caS N O - O - O d O c O _ C L Cn A/ O - V O 3�, �- 0e m zN m W � L I olo � I I ® O 0 00 w U I Oo < z CO 0 = o DECK CONFERENCE ROOM 110 3 E o V M1-39 N5-3 I 0 j N6-4 75 � N5-4 1 C 1 75 C 1 --TV C o 0 U N5-5 C V M1-38 Cn L ORS 75 N6-3l' I Q pH D C � ITS P` Z 15 DN. V .. , V j p CIO � ` G 1 M 1-30 _ N5-2 I I I o M H. O I P 0 I I U I T M1-34 j s ------------------- W 1 v 2UU mil i -- I m 5-6 15 F TELE. 30 C o M1-32 LU 5 15 I6-5 V N6-6 I N6-1 15 15 C ! V M1-35 5-1 ® N6-2 M1-36 ®� V M1-33 V AREA OF WORK j C C AREA OF WORK F _ H a P�d 75 I _- II E ( I ORIENTATION M1-37 N5-7 �( i I -- (RL) I i O i V o C I j 1/ 5 r 15 BREAK N5-11 EQUIP OFFICE OFFICE 0 o 15 C C 15 DN. it °' V `I , EOLR i 30 Y V x( N6-9 --- - I i C j �, I r-------�r- -----� I ! V 1 d ( ----- �-\ N5-9 Ir-------- ---- C II i(RL)ILU 30 - 1 1 I I I I w jl I 3 ILIZ i I i i i I i ': 0 co CV ------J L-�-----J O FITT I C N5-10 V I I I I I 15 Ch I II` JI L_ _ 3 W Y �' I , , , N6-7 , O N I I V Ly (RL) C i I cn a N V I ! 1 r--------ir--------, r--------tr---- -- a2u yi 30 r------- II I I IICn W I 30 OPEN O�FICE ; 11 75 li -�� 175 I I { 3 i tcc z CN5-8 N6-10 I II I I I II (RL)I\j L) N6-8 i i ' DRAWN BY: R. HERMANT j EOLR 1 C I u I I n I I C Of i 15 V I II I I CIL C II I C I I II CHECKED BY: J.JOHNSON j I � N5-12 EOLR1 15 L--_----JL--- ---J L-------JL-------J �_____=_; ISSUE DATE: 5/28/13 r--------Ir-------I l r--------Ir------- I C/) ( i C (RL) N6-11 ; I n I I II I , , OFFICE OFFICE ;I: JOB#: E E I INN I II I I I II I I 1 Ih PROJECT#: 448:970977701 DECK INTV I I o LI a I I II I I I ! SIMPLEXGRINNELL© 2013 a II I I II I _ I I _ - S - - ' � S EM• i I WVRn (U N I i CM SHEET: co i PIAN PIAN DEVICE PLACEMENT PLAN & Cn Cc = c NORTH NORTH CALCULATIONS DEVICE PLACEMENT PLAN 2ND FLOOR KEY PLAN 2ND FLOOR a0 SCALE: 1/8 n=19-0" w W 0 4 8 12CD 0 (IN FEET) ~ " w _ � cc FA-101 E z � . z0 X W . � U) 2 CL ca L DEVIL END—OF—LINE E MOUNTING HEIGHT REFERENCE .(PER NFPA `�2) END OF LINE RESISTOR CODES A/C SUPPLY VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMSo OR RETURN NOTE. REFER TO PANEL/MODULE AND DEVICE INSTALLATION MU-) 1. MIN DISTANCE IN SLEEPING ROOMS IS 24 (610mm) FROM CEILING TODIFFUSER THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS INSTRUCTIONS FOR PROPER TERMINATIONS. CO ' TOP OF LENS FOR 11 OCD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 - �� 2 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24 * USE WITH RETROFIT OR HIGH CURRENT MODULE (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' MIN 4 NOTE: MEASUREMENTS o INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. ( ) (102mm) SHOWN ARE TO THE MODEL REFERENCE OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL MODULE \ a-U_ (914mm MIN) CEILING _ CLOSEST EDGE OF THE NUMBER PANEL/MODULE w DETECTOR. CL 4081-9001 733-892 2.2K RED RED RED - GOLD N A 1 2 ANNUNCIATOR 4300 4004 4010 TROUBLE � _ • N.O. INITIATING 4004*, 4004R, 4005*, 4006, ® ;o� X CEILING MOUNTED PULL SMOKE HEAT, 4100, 4120, 41000, ZAM'S00f °' FOR CEILING HEIGHTS LESS THAN 86 (2180mm), NFPA 72 AUDIBLE APPLIANCE 4 _ _ ® 0 THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN '152.4mm MIN SMOKE/HEAT (102mm 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, ETC. `� �C „ l ) DETECTOR ) 12 (MAX) - �o M o 24 PT. I/O SWITCH SUPV. 4605 7401, 4100 SERIES E WITHIN 6 (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING (305mm MAX) r _ v� U' HEAT DETECTORS CURRENT LIMITED N.O. INITIATING 4090 9001 IDNET IAM EOLR � w�W 90 MIN (2286mm MIN) ACCEPTED HERE 4081-9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 NOTIFICATION�DACT 2080-9024 S3 `�o> o ABOVE FINISHED FLOOR NEVER HERE e N.O. INITIATING 4004 4005, ca v ��� (OTHER MOUNTING HEIGHTS SHALL BE 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAM PERMITTED BY THE AHJ PROVIDING IT AUDIBLE/VISUAL -- - WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PT 1/0 yMEETS THE SOUND LEVEL OUTPUT REQUIRED.) 4-20MA ZAM TROUBLEco & VISUAL ONLY WALL MOUNTED CURRENT LIMITED N.O. INITIATING w APPLIANCES TO EXIT DOOR SMOKE/HEAT 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 4090-9001 IDNET IAM °' 5' IN LINE) (MAX.)( ) DETECTOR (1524mm) 4081-9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM SYNCHRONIZE MORE THAN DOOR ' TWO APPLIANCES IN ANY WIDTH 4100, 41000 - a FIELD OF VIEW. LESS 3" 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 (76mm) 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008) o 4009, 4010, 4100, 41000 96 MAX (NFPA) 5„ "�" "" SIDE WALL 4081-9009 733-912 20n RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 (2440mm MAX) (127mm) N.C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM ABOVE FINISHED FLOOR 24 PT. 1/0 (ACROSS CONTACTS) 4605-7401, 4100 SERIES 92 REF. 80 MIN (IBC) MANUAL 4081-9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 CURRENT LIMITED N.O. INITIATING 2 (2032mm MIN) TO TOP OF LENS PULL (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM REF. 96" MAX IBC STATION (IBC) 80" (ADA) (2032mm) FIRE 4081-9011 733-974 100 BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 (2440mm MAX) 80" MIN (NFPA) (2032mm MIN) PHONE MAGNETIC 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 ABOVE FINISHED FLOOR JACK ® DOOR 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1 2 TO BOTTOM OF LENS HOLDER N.C. INITIATINGca Cn 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 4090-9001 IDNET IAM FINISHED (SECURITY MONITORING EOLR) ® WALL , NOTE: REFER TO THE PROPER DEVICE 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM INSTALLATION INSTRUCTIONS 48 MAX (ADA) (1219mm) (SECURITY MONITORING EOLR) CD FOR BACKBOX MOUNTING HEIGHT. 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 48 MAX (NFPA) (1219mm MAX) 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 FINISHED 42 MIN (NFPA) (1067mm MIN) / FLOOR 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 MEASUREMENTS SHOWN AREco TO TOP OF PULL HANDLE 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING EOLR 4100, 41000 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 41000 0 a 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41000 0 ci 0 TrueAlert� NON—ADDRESSABLE MULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE TrueAlert7 NON—ADDRESSABLE MULTI—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE U PRODUCT INFORMATION o PRODUCT INFORMATION (CEILING MOUNT) (CEILING MOUNT) Cn FEATURES: FEATURES: •UL LISTED TO STANDARD 1971 (ERICO N0. 512) T-BAR • CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION Q ADA COMPATIBLE WITH CLIPS AND SCREWS N SUPPLIED BY CONTRACTOR TO A COMPATIBLE SMARTSYNC NAC OR TO a SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: SMARTSYNC CONTROL MODULE (SCM) 4905-9938 •SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE " • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE FOR CLASS B OR CLASS A OPERATION HANDY BOX, 1-1/2 DEEP OR 4905-9938 SCM OR 4100 SERIES FIRE ALARM 4" SQUARE BOX, 1-1/2" DEEP o SINGLE GANG BOX, 2-1/2" DEEP CONTROL PANEL NAC'S OPTIONAL 4905-9928 ADAPTER PLATE. o •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE SUPPLIED BY OTHERS REQUIRED FOR SURFACE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS SINGLE GANG BOX SPECIFICATIONS: - - - MOUNTED ELECTRICAL BOX (WIREMOLD V5744S) • HOUSING DIMENSIONS (INCLUDING LENS) 4-3/4"L X 6-7/8" W X 2-5/8"D o SPECIFICATIONS: 2-1/4" (57mm) •HOUSING DIMENSIONS: 4-3/4" L X 2-5/16- W X 2-5/8" D (121 mm X 75mm X 67mm) p SUPPLIED BY OTHERS TEMPERATURE RANGE: 32 F TO 122' F (0 TO 50 C) 0 U. U. o 0 •TEMPERATURE RANGE: 32'F TO 122'F (0 TO 50'C) • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100' F (38' C) I • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER OPTIONAL 4905-9915/-9916 ADAPTER •HUMIDITY RANGE: 10� TO 93% NON-CONDENSING A7 100'F (38'C) o 4905-9910 ADAPTER PLATE, TERMINAL FOR IN/OUT WIRING. •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER 000 REQUIRED FOR SURFACE MOUNT TERMINAL FOR IN/OUT WIRING. F WITH HANDY BOX UNLESS USING R THE 4905-9926 WIRE GUARD WIRING TERMINALS ARE STROBE LOCATED BEHIND HOUSING OPTIONAL 4905-9927co WIRING NOTES: - RATED VOLTAGE-RANGE: UL- 16 VDC TO 33 VDC PER UL 1971 nn RED FIRE GUARD 0 W a 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. IF O (� ULC: 20VDC TO 30VDC PER ULC S526-M878 c U - FLASH RATE: 1 Hz STROBE INTENSITY VIEWING 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP - - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. _ WIRES UNDER TERMINALS. - �,-----------.-------------, �� �--- Strobe intensity � - 3. ALL NAC WIRING CONNEC11ONS ARE SUPERVISED AND POWER-LIMITED. viewing slot — -' :..►R w L 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. ,' o Intensity selection plug, ; INTENSITY SELECTION PLUG, o ' accessible only from rear of lens *CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. ACCESSIBLE ONLY FROM REAR OF LENS housing;factory setting is 15 cd; HOUSING LETTERING RMS CURRENT ® HOUSING, FACTORY SETTING IS 15cd 2 STROBE: MODEL NUMBER COLOR COLOR RATING 4VDC -------------------------- 4 - c m mA mA c •RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 OPTIONAL 4905-9926 WIRE GUARD c m m m ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 CEILING MOUNT WITH MOUNTING PLATE c m mA 1 mA •FLASH RATE: 1 Hz c m m 1 m •SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. - c mA 7fi mA 57 mA FROM FACP 24VDC NON-CODED TO ADDITIONAL NOTIFlCATTON c m 117 mA 88 mA �� + An- APPLIANCE DEVICE OR RETURN c m 222 mA 167 mA NOTIFICATION APPLIANCE CIRCUIT �— — —� TO FACP FOR STYLE Z APPLICATION c m 284 mA 213 mA *CURRENT DRAWS REFLECT STROBE FLASHING OR PRECEDING DEVICE, OR Z— —� IF LAST DEVICE ON CIRCUIT INA HOUSING LETTERING RMS CURRENT SIMPLEX 4905-9914, 9922, OR + STYLE Y APPLICATION PLACE AN MODEL NUMBER COLOR COLOR RATING 1 4 9938 SYNC MODULE. END-OF LINE RESISTOR. (RESISTOR C� Y 4906-91-02 c mA m m VALUE IS FACP DEPENDENT.) HORN c c mA 1 mA 1 m - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, m OR— 1 mA mA 11 mA MODULATED AT 120 Hz RATE Z co 4906-9104 c mA 67 mA 50 mA 0 0 8 P� o oCN c mA 111 mA 83 mA N c m 207 mA 155 mA 11 c m 281 mA 211 mA • HORN SOUND OUTPUT RATINGS ® 10 FT. (3m) L CKr+CKr- CKr+CKT- VOLTAGE 16 VDC 24 VDC 33 VDC ® O SOUND TYPE * STEADY CODED STEADY CODED STEADY CODED z C3 CCE I REVERBERATE CHAMBER U J C/) ID UL 464 TEST 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA 0 o O O ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA - END-OF-LINE V O FROM FACP 24VDC NOTIFICATION + + o * RESISTOR (VALUE z o CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL APPLIANCE CIRCUIT OR SIMPLEX I�� 'DEPENDENT CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER 4905-9914, 9922 OR 9938 IS FACP 0 0 READING ON A "FAST" SETTING. UNDER THE SAME TEST CONDITIONS, CODED SYNC MODULE OR PRECEDING DEVICE � HORN OUTPUT "PEAK" SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. 01 E o 0 CD 3 g v, � c Q 0 m c 0 .c o c z c Q CC o C m co W a Lu Q - - - CUE - - Z 0 Y7 J 0- � c 0 o W m O o c_ _2 N N V N O Li.. . w O cc N E M 0 LU Y M u ¢ .o O o N a, O w N^^ Y! d z DRAWN BY: R. HERMANT CHECKED BY: J. JOHNSON Co ISSUE DATE: 5/28/13 T Q , -' JOB#: PROJECT#: 448:970977701 0 SIMPLEXGRINNELL© 2013 F a o � SYSTEM: ti FIRE ALARM SYSTEM a cc N SHEET: � ca z WIRING TYPICALS Co co Cc Q� N m CA w E LU CD W - _ - U c CN FA-701cc Z y O � a> M O E � fO - L