Specifications
RECEIVED JAN 282013 CITY OFTIGARD BUILDING DIVISION STANLEY SECURITY SOLUTIONS 15495 S.W. SEQUOIA PARKWAY PORTLAND, OR 97224 O Reference: FIRE ALARM SYSTEM ORCHARD SUPPLY HARDWARE 10031 S.W. CASCADE AVE TIGARD , OR 97223 ANY QUESTIONS CONCERNING THIS SUBMITTAL PLEASE CALL; SCOTT BELINN @ 503-968-3362 j11.11.11111111111111 .1.11. SEQUENCE OF OPERATION UPON RECEIPT OF ANY DEVICES A THRU C ITEMS 1,2,3 AND 4 WILL OCCUR, UPON RECEIPT OF ANY A. MANUAL PULL STATION B, SPRINKLER WATER FLOW C, SMOKE DETECTOR ALARM FIRE ALARM SYSTEM WILL: 1. INDICATE ALARM AT FIRE ALARM PANEL, 2, INDICATE ALARM AT ANNUNCIATOR/KEYPADS 3, SEND ALARM SIGNAL TO OFF SITE, 4, ACTIVATE ALL NOTIFICATION APPLIANCE CIRCUITS (HORN/STROBES), UPON RECEIPT OF ANY SPRINKLER TAMPER SIGNAL ITEMS 5, 6 AND 7 WILL OCCUR, UPON RECEIPT OF ANY SPRINKLER TAMPER SIGNAL ITEMS 5, 6 AND 7 WILL OCCUR. FIRE ALARM SYSTEM WILL: 5, INDICATE SUPERVISORY AT FIRE ALARM PANEL, 6. INDICATE SUPERVISORY AT COMMAND CENTER/KEYPADS 7, SEND SUPERVISORY SIGNAL TO OFF SITE, RISER DIAGRAM INDICATES RISER CONFIGURATI❑N, REFER TO FLOOR PLANS FOR L❑CATI❑N OF DEVICES, DF-52418:C•A1-20 MS-9050UD(E) esj FIre•LITeffALarms Fire Alarm Control Panel with DACT by Honeywell Addressable General The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- - sive list of powerful features,the MS-9050UD programs just like Fire•Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms,troubles,AC loss, etc.)to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ -_ . Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows"' 95 or greater, and compatible modem with a speed of 14.4 kbps or ;eI�•EZZn-=. faster and Fire•Lite Upload/Download software kit PK-CD, may " " serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data,current status and system voltages. • Point trouble identification. The power supply and all electronics are contained on a single • Waterflow selection per module point. circuit board supported on a new quick install chassis and • Alarm verification selection per detector point. housed in a metal cabinet. Available accessories include local • Maintenance alert warns when smoke detector dust accumu- and remote upload/download software, remote annunciators, lation is excessive. and reverse polarity/city box transmitter.(4XTMF) • One-person audible or silent walk test with walk-test log and New options include a UL listed printer, PRN-6F and the new printout. IPDACT Internet Monitoring module. The FireWatch Series • System alarm verification selection per detector point. internet monitoring modules IPDACT-2 and IPDACT-2UD permit • monitoring of alarm signals over the Internet saving the monthly PAS (Positive Alarm Sequence) and Pre signal per point cost of two telephone lines. Although not required, the second—(NFPA 72 compliant). ary telephone line may be retained providing backup communi- • Up to eight ANN-BUS annunciators. cation over the public switched telephone line. • Remote Acknowledge, Alarm Silence, Reset and Drill via NOTE: Unless otherwise specified, the term MS-9050UD is used addressable modules or remote annunciator. in this data sheet to refer to both the MS-9050UD and the MS- • Upload/Download (local or remote) of program and data via 905OUDE FACPs. For MS-905OUDC,refer to DF-60445. integral DACT. Features SLC COMMUNICATION LOOP • Single addressable SLC loop which meets NFPA Style 4, 6 • Listed to UL Standard 864,9th edition. and 7 requirements. • Auto-program (learn mode) reduces installation time. • 50 addressable device capacity(any combination of address- Reports two devices set to the same address. able detectors and modules). • On-board DACT. • Compatible with Fire•Lite's addressable devices(refer to SLC • Two independently programmable Style Z (Class A) or Style Wiring Manual). Y(Class B) NAC circuits. • Selectable strobe synchronization for System Sensor, Whee- NOTIFICATION APPLIANCE CIRCUITS(NAGS) lock,and Gentex devices. • Two independently programmable output circuits. Circuits • Remote Acknowledge, Silence, Reset and Drill via address- can be configured for the following outputs: able monitor modules. - Style Y(Class B) • Two programmable relays and one fixed trouble relay. -Style Z(Class A) • Built-in Programmer. -Door Holder Service(cannot be used for notification appliances) • Telephone Line Active LEDs. -Aux Power Source(cannot be used for notification appliances) • EIA-232 PC interface. • Silence Inhibit and Autosilence timer options. • Integral 80-character LCD display with backlighting. • Continuous, March Time, Temporal or California code for • Real-time clock/calendar with automatic daylight savings main circuit board NACs with two-stage capability. control. • Selectable strobe synchronization per NAC. • History file with 500 event capacity. • 2.5 A total power for NACs. • Automatic detector sensitivity testing(NFPA 72 compliant). NOTE: Maximum or total 24VDC system power shared between • Automatic device type-code verification. all NAC circuits and the ANN-BUS is 2.7 A. DF-52416:C•12/16/2009—Page 1 of 4 PROGRAMMING AND SOFTWARE • Autoprogram(learn mode)reduces installation time. a • Custom English labels (per point) may be manually entered or selected from an internal library file. • Two programmable Form-C relay outputs. • 20 software zones. • Continuous fire protection during online programming at the front panel. MS-9050UD -- • Program Check automatically catches common errors not Fre Alarm - - linked to any zone or input point. Control Panel OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package ANN 8D (order programming kit PK-CD, containing PK-Plus, sepa- rately).Upload/download system programming locally. S0355 Printer User interface Photo Detector Gateway LED INDICATORS ANN-S/PG • AC Power(green) "i— • Fire Alarm(red) r�='r • Supervisory(yellow) AD355 Graphic LED Module • Trouble(yellow) Adapt Detector ANN VO • Alarm Silenced signals(yellow) ,.•a?- KEYPAD • 16 key alpha-numeric pad H355/H355R/H355HT Relay Module • Acknowledge/Step Heat Detector ANN RLY P2R • Alarm Silenced Strobe • Drill(Manual Evacuate) II • Reset(lamp test) MDF-300 Product Line Information Dual Monitor Module P2R MS-9050UD(E): Combination DACT/Fire Alarm Control Panel Strobe with one SLC loop. Includes main circuit board with display, e. N Power Supply chassis with transformer,backbox with door,plastic bag contain- ,. , � — FCPS 24FS6 ing screws, cables, key, etc., manual. (For MS-905OUDC, refer FCPS-24FS8 SD355T •t)' to DF-60445.) Photo/Thermal PK-CD: Contains PK-Plus programming software for Win- L-, .- P2R dows®-based PC computer(cable not included). - . Strobe DP-51050:Optional dress panel for the MS-9050UD. Multi Modules TR-CE:Optional trim ring for semi-flush mounting. MMF-300 • CRF-300-6 Six-Relay Control Module BB-2F:Optional cabinet for one or two modules. Monitor Module • CMF-300-6 Six-Circuit Supervised Control Module BB-6F: Optional cabinet for up to six modules mounted on • • MMF-302-6 Six-Zone Interface Module CHS-6 chassis. • MMF-300-10 Ten-Input Monitor Module BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. MMF-302 BB-55F:Battery box,houses two 55 AH batteries 2-Wire Detector Monitor Module i CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of ' 25 to 75 AH. D355PL Beam Detector CHG-120F: Remote battery charging system for lead-acid bat- Duct Detector BEAM 3351(5) teries with a rating of 55 to 120 AH.Requires additional BB-55F for mounting. FIRE MS_9O5OUD BAT Series: Batteries,see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface �,.E____1 ADDRESSABLE FIRE ALARM cable. CONTROL PANEL PRN-6F: UL listed compatible event printer. Uses tractor-fed BG-12LX Addressable paper. Manual Pull Station IPDACT, IPDACT 2/2UD Internet Monitoring Module: Mounts ( in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to,primary and secondary DACT telephone output ports for internet communications over customer provided ether- Page 2 of 4—DF-52418:C•12/16/2009 net internet connection. Requires compatible Teldat Visoralarm resistor. Module may be configured for either a Style B(Class B) Central Station Receiver. Can use DHCP or static P. (See data or Style D(Class A) IDC. sheet df-52424 for more information.) MDF-300: Dual Monitor Module. Same as MMF-300 except it IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. provides two Style B(Class B)only IDCs. IPSPLT: Y-adaptor option allows connection of both panel dialer MMF-301: Miniature version of MMF-300. Excludes LED and outputs to one IPDACT-2/2UD cable input. Style D option. Connects with wire pigtails. May mount in device AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in backbox. turn, mounts to the FACP chassis. Use AC-TRMBLK when wire MMF-302A: Similar to MMF-300A.Addressable Monitor Module nuts are not allowed for AC connections to the transformer. for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- OPTIONAL MODULES ment for listed compatible devices and quantity limitation. 4XTMF Reverse Polarity Transmitter Module: Provides a CMF-300:Addressable Control Module for one Style Y/Z(Class supervised output for local energy municipal box transmitter, B/A) zone of supervised polarized Notification Appliances. alarm and trouble. Includes a disable switch and disable trouble Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification LED. Appliance Circuit option requires external 24 VDC to power noti- COMPATIBLE ANNUNCIATORS fication appliances. ANN-80(-W):Remote LCD annunciator mimics the information CRF-300: Addressable relay module containing two isolated displayed on the FACP LCD display. Recommended wire type is sets of Form-C contacts, which operate as a Dmou switch. un-shielded.(Basic model is red;order-W version for white;see Mounts directly to a 4.0" (10.16 cm.) box, surface mount using DF 52417.) the SMB500. ANN-1/O: LED Driver Module provides connections to a user BG-12LX: Addressable manual pull station with interface mod supplied graphic annunciator. (See DF-52430.) ule mounted inside. ANN-LED: Annunciator Module provides three LEDs for each 1300:This module isolates the SLC loop from short circuit condi- zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) SMB500: Used to mount all modules except the MMF-301 and ANN-RLED: Provides alarm (red) indicators for up to 30 input M301. zones or addressable points. (See DF-60241.) MMF-300-10:Ten-input monitor module.Mount one or two mod- ANN-RLY: Relay Module provides 10 programmable Form-C ules in a BB 2F cabinet(optional). Mount up to six modules on a relays. Can be mounted inside the cabinet. (See DF-52431.) CHS-6 chassis in a BB 6F cabinet. ANN-S/PG: Serial/Parallel Printer Printer Gateway module pro- MMF-302-6: Six zone interface module.Mount one or two mod vides a connection for a serial or parallel printer. (See DF- ules in a BB-2F cabinet(optional). Mount up to six modules on a 52429.) CHS-6 chassis in a BB-6F cabinet. CMF-300-6:Six-circuit supervised control module.Mount one or ADDRESSABLE DEVICES two modules in a BB-2F cabinet(optional). Mount up to six mod- All feature a polling LED and rotary switches for addressing. ules on a CHS-6 chassis in a BB 6F cabinet. CP355: Addressable low-profile ionization smoke detector. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules SD355: Addressable low-profile photoelectric smoke detector. on a CHS-6 chassis in a BB-6F cabinet. SD355T: Addressable low-profile photoelectric smoke detector NOTE: 1) For more information on Compatible Addressable with thermal sensor. Devices for use with the MS-9050UD, see the following data H355: Fast-response, low-profile heat detector. sheets (document numbers): AD355 (DF-52386), BG-12LX (DF- H355R: Fast response, low profile heat detector with rate-of- 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ rise option. CRF Series (DF-52130), CP355 (DF-52383), D350PL(A)/ D35ORPL(A) (DF-52398), H355 Series (DF-52385), 1300 (DF- H355HT: Fast-response, low-profile heat detector that activates 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 at 190°F/88°C. (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF- AD355: Low-profile, intelligent, "Adapt" multi-sensor detector 52384). (B35OLP base included). ADDRESSABLE DEVICE ACCESSORIES BEAM355: Intelligent beam smoke detector. End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k BEAM355S: Intelligent beam smoke detector with integral sen- ohm supervises the MMF-300, MDF-300, MMF-301, and CMF- sitivity test. 300 module circuits. 3.9k ohm End-of-Line Resistor assembly D355PL:Innovair Flex low-flow non-relay duct-detector housing; supervises the MMF-302 module circuit. These resistors are includes SD355. included with each module. DNR: Innovair Flex low-flow non-relay duct-detector housing. Power Supervision Relay: Supervises the power to 4-wire (Order SD355 separately.) smoke detectors and notification appliances. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355 separately.) Wiring Requirements MMF-300: Addressable Monitor Module for one zone of nor- While shielded wire is not required, it is recommended that all malty-open dry-contact initiating devices. Mounts in standard SLC wiring be twisted-pair to minimize the effects of electrical 4.0" (10.16 cm.)box. Includes plastic cover plate and end-of-line interference. Refer to the panel manual for wiring details. ,......� DF-52418:C•12/16/2009—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity condensing) at 32°C t 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- • Intelligent Signalling Line Circuits 1 nents may be adversely affected by extreme temperature ranges • Addressable device capacity 50 and humidity. Therefore,it is recommended that this system and • Programmable software zones 20 its peripherals be installed in an environment with a normal room • Annunciators 8 temperature of 15-27°C/60-80°F. Electrical Specifications NFPA Standards AC Power MS 9050UD 120 VAC,60 Hz,3.0 A.MS 9050UDE: The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: 240 VAC,50 Hz, 1.5 A.Wire size:minimum 14 AWG(2.00 mm2) with 600 V insulation.Nonpower-limited,supervised. -LOCAL (Automatic, Manual, Waterflow and Sprinkler Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Supervisory). Capacity:7-18 AH (MS-9050UD cabinet holds maximum of two -AUXILIARY (Automatic, Manual and Waterflow) (requires 18 AH batteries.) 4XTMF). Communication Loop: Supervised and power-limited. -REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed nections for two NACs, Style Y (Class B)or. Style Z(Class A). transmitters. For reverse polarity signaling of alarm and Special Application power. Power-limited, supervised circuitry. trouble,4XTMF is required.) Maximum signaling current per circuit:2.5 A. End-of-Line Resis- -PROPRIETARY(Automatic,Manual and Waterflow). tor:4.7 kohm, 'h watt(P/N 71252 UL listed)for Style Y(Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for -CENTRAL STATION (Automatic, Manual and Waterflow, listed compatible devices. and Sprinkler Supervised). Two Programmable Relays and One Fixed Trouble Relay: -OT,PSDN(Other Technologies, Packet switched Data Net Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A it 30 VAC work) (resistive). Form-C relays,nonpower-limited, nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.72" 9050UD(E)control panel. In some cases, certain modules may (1.82 cm.) deep. Backbox 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in (42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring(TR-CE): process.Consult factory for latest listing status. 22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • UL: S624 �. • FM approved Shipping Specifications • CSFM:7165-0075:210 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA:442-06-E high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. NOTE:See DF-60445 for ULC-listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32-120°F and at a relative humidity 93%±2%RH(non- FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E Is T F 1 E D We cannot cover all specific applications or anticipate all requirements. MUM A 1M INAT1lN All specifications are subject to change without notice. `leem.nom. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)6994105. www.firelite.com Page 4 of 4—DF-52418:C•12/16/2009 df-52417:c•B-90 ANN-80 ej Fire uTe9Alarms 80-Character LCD Serial Annunciator by Honeywell Annunciators General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- - - Lions. The ANN-80 and the FACP communicate over a two-wire - serial interface employing the ANN-BUS communication format. _ Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed,filtered power supply. ANN-80 is red;for white,order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point • alarm, trouble or supervisory status, as well as any custom J alpha labels programmed into the control panel. It includes con- "=. ' trol switches for remote control of critical system functions. (A -- by Honeywell ,,,,;q i keyswitch prevents unauthorized operation of the control 4,, - switches.) — -, -- Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required,which saves time dur- ing system commissioning. Features • Listed to UL Standard 864,9th Edition. • • Backlit 80-character LCD display(20 characters x 4 lines). Supervisory • • Mimics all display information from the host panel. Alarm Silenced • Control switches for System Acknowledge, Signal Silence, Drill,and Reset. Specifications • Control switches can be independently enabled or disabled • Operating voltage range: 18 VDC to 28 VDC. at the FACP. • Current consumption Q 24 VDC nominal(filtered and non- • Keyswitch enables/disables control switches and mechani- resettable):40 mA maximum. cally locks annunciator enclosure • Ambient temperature:32°F to 120°F(0°C to 49°C). • Keyswitch can be enabled or disabled at the FACE • Relative humidity: 93%±2%RH (noncondensing)at 32°C • Enclosure supervised for tamper. ±2°C(90°F±3°F). • System status LEDs for AC Power, Alarm, Trouble, Supervi- • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" sory,and Alarm Silence. (3.49 cm.)deep. • Local sounder can be enabled or disabled at the FACE • For use indoors in a dry location. • ANN-80 connects to the ANN-BUS terminal on the FACP and • All connections are power-limited and supervised. requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- Agency Listings and Approvals ble,supervisory,zone,and custom alpha labels. • Time and date display field. The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval • Surface mount directly to wall or to single, double, or 4" agencies,or listing may be in process. Consult factory for latest square electrical box. listing status. • Semi-flush mount to single, double, or 4" square electrical • UL:S2424 box. Use ANN-SB8OKIT for angled view mounting. • • Can be remotely located up to 6,000 feet(1,800 m)from the• approved panel. • CSFM: 7120-0075:211 • Backlight turns off during AC loss to conserve battery power • MEA:442-06-E but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote The ANN-BUS power supply(requires 24 VDC). • Up to eight ANN 80s can be connected on the ANN BUS. POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY Controls and Indicators The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the • AC Power ANN-BUS power requirements. See the FACP manual for more • Alarm information. • Trouble df-52417:c•05/22/09—Page 1 of 2 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw,the following Each ANN-BUS device requires a unique address (ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP A maximum of 8 devices located from the FACP on a single wire run. The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum. In general,the wire length is liin- See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk('). Maxi- The ANN-80 connects to the FACP ANN-BUS communications mum length can never be more than 6,000 feet (1,800 m), circuit. To determine the type of wire and the maximum wiring regardless of gauge used. See table below. distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75-2.08 mm2) wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. Power wire distance limitation is set by 1.2 case currents for each module. volt maximum line drop form source to end of circuit. NOTE: For total worst case current draw on a single ANN-BUS • All connections are power-limited and supervised. refer to appropriate FACP manual. • A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. •6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80:Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SBBOKIT R: Red surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB80KIT--W: White surface mount backbox with angled 1710721:11 wedge. Tel Fi0Vi'A 4 3 2 1 ANN-BUS Device rmTni= 0 MS-9050UD TB300000000 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device FireLite©Alarms is a registered trademark of Honeywell International Inc. • _ ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. IMEMOXED We cannot cover all specific applications or anticipate all requirements. frommomanuminwr MINORING 6 MANUFAGIDAING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-52417:c•05/22/09 SYSTEM �$ SENSOR' f 4 ty Indoor Selectable. Output Horns, L. F '"i Strobes, and s= ; 1_ � r Horn Strobes for a E 3- Wall Applications _- I - SpectrAlert Advance audible visible notification products SPECTR Nert are rich with features guaranteed to cut installation times tanaray a N c and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela • Field-selectable candela settings on wall units: 15,15/75,30,75, Like the entire SpectrAlert Advance product line,wall-mount horns, 95, 110, 115, 135,150, 177,and 185 strobes,and horn strobes include a variety of features that Increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring continuity before the device is installed. • Compatible with MDL sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ® MEA LISTED APPROVED approved 7125.1653:1666ndoo strobes) 7125-1653:166(non strobes, S4011(chimes,horn strobes,horns) 3023572 MEA452-05-E Chime strobes) 85512(strobes) 71354653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicallElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.3"D(142 mm L x 119 trim W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0-W x 2.2-D(151 mm L x 128 mm W x 56 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW- 5.7-L x 4.8-W x 0.35"D(145 mm L x 122 mm W x 9 mm D) HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVV0S00601 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) • 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded • High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 gt Coded Low 75 75 81 81 88 85 96 92 tsettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00601 SpectrAlert Advance Dimensions 4.7" 5.05" 10_2.231 r -� AIR!�f '. f t .c� 5.98" Or=== ll li . b000d Wall-mount horn strobes Wall back box skirt • SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Horns P2R•t 2-Wire Horn Strobe,Standard cdt,Red HR Horn,Red P2RH* 2-Wire Horn Strobe,High cd,Red HW Horn,White P2W' 2-Wire Horn Strobe,Standard cd,White Accessories P2WH* 2-Wire Horn Strobe,High cd,White BBS-2 Back Box Skirt,Wall,Red P4R* 4-Wire Horn Strobe,Standard cd,Red BBSW-2 Back Box Skirt,Wall,White P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red _ P4W 4-Wire Horn Strobe,Standard cd,White TRW-HS Trim Ring,Wall White Wall Strobes SR't Strobe,Standard cd,Red SRH*t Strobe,High cd,Red SW* Strobe,Standard cd,White SWH• Strobe,High cd,White Notes: •Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO°marking on cover,e.g.,P2R-SP. #'Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings.'High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTEM 02012 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Produc�speceicauon ssbjeamchangewivan,wccaNs•systernsensoccom SENSOR Phone:800-SENSOR2•Fax:630-377-6495 to current product hlorn1E"on,including the latest ye/son W this data Sheet AVDS00601•3/12 July 14,2004 DF-52347•E-900 - 0Fi re•LiTe°ALarms nnnnF-300-1 o(A) J Ten-Input Monitor Module www.firelite.com Section: Addressable Devices GENERAL The Fire-Lite Alarm's MMF-300-10(A) ten-input monitor California module provides an interface between the MS-9200, MS- State Fire 92000D or MS-9600 and normally open contact devices Marshal such as pull stations, security contacts, or flow switches. j"" .�) 7300-0075:205 The first address on the MMF-300-10 (A) is set from 01 to LASTED APPROVED 150 and the remaining modules are automatically as- S3705 MEA signed to the next nine higher addresses. Provisions are 55-02-E included for disabling a maximum of two unused ad- dresses. The supervised state (normal, open, or short) of the moni- CSXXXX tored device is sent back to the panel.A common SLC input is used for all modules, and the initiating device loops share a common supervisory supply and ground—otherwise each monitor operates independently from the others. rp•sv. c...0,Noe coSN c.wee cave cw•w Each MMF-300-10(A) module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, 1 latch on, or latch off. - •�'' 1'•�' - . -- • `• • . rz -�.� a.....s r- 77 r-+^-r91, FEATURES = ...�i..... ....�......, ..444: • Ten addressable Class B or five addressable Class A '` -:A...!• initiating device circuits. ■ 0`ei,_ • Removable 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2) I= _ plug-in terminal blocks. + A d j.i•Q }10• •10.0- \_ i1 iii t, '1,N.i' ,"•N. • Status indicators for each point. t^ ^ j; b • Unused addresses may be disabled. ;t• -' 31: 11' .�" t...1,.�` t; Fi: • Rotary address switches. ;•; • •L, ;•ii. '.it°'''': ii•' '1I—• • :. • Mount one or two modules in a BB-2F cabinet(optional). _ • -r G • -.�,K� • Mount up to six modules on a CHS-6 chassis in a ")t,�0 r `1.�1.J BB-6F (BB 6F and CHS 6 sold seperately). . : • — Yam h • Mounting hardware included. �„- Ill-; ;I1 � ®l_gs,�z; SPECIFICATIONS - .!_-.1-:__• • •`'•'- 't Standby current: 3.5 mA (SLC current draw with all ad '® ''®. • =.• •' -O: dresses used if some addresses are disabled, the standby 'A"`- .' "' ::.:;:g r-- current decreases). = .�,. -'–«` .7` -••” 44.7'�- N N current: 60 mA (assumes all ten LEDs solid ON). EEL- Alarm '1 Temperature range: 32°F to 120°F (0°C to 49°C) for UL applications. Humidity: 10% to 85% noncondensing for UL applications; 10% to 93% noncondensing for EN54 applications. Maximum SLC wiring resistance: 40 or 50 ohms, panel Dimensions:6.8"(172.72 mm)high x 5.8"(147.32 mm)wide dependent. x 1.25" (31.75 mm) deep. Maximum IDC wiring resistance: 1500 ohms. Shipping weight: 1.1 lb. (0.499 kg) including packaging. Maximum IDC voltage: 12 VDC. Wire gauge: 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2). Maximum IDC current: 1 mA. Power-limited circuits must imply type FPL, FPLR, or PRODUCT LINE INFORMATION FPLP cable as required by Article 760 of the NEC. MMF-300-10 is shipped in Class B position; remove shunt MMF-300-10: Ten-input monitor module. for Class A operation. MMF-300-10(A):Ten-input monitor module (Canada). This• document Alarms is a to Honeywell to company. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. CERTIFIED For more information, contact Fire•Llte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. FNCINFFRIN6 A MANUFACTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52347•07/14/04 —Page 1 of 2 52347w1.wmf WIRING DIAGRAMS +a) I - + Q IDC1 CONNECT MODULES TO +,. FIGURE 1: LISTED COMPATIBLE Typical Initiating Device CONTROL PANELS ONLY. + N.@ Circuit Configuration — 1 + IDC 2 Class B, Style B. + CO o NOTE:Any number of UL-Listed contact 1 + closure devices may be used. DO NOT I I + MIX ire alarm initiating and supervisory 47K EOL +• IDC 3 devices on the same initiating device cir- RESISTOR — + �-g cult. Install contact closure devices per ELR-47K I + _ manufacturer's installation instructions. + co a 11004+ N o CLASS B IDC(TYPICAL) I + ° NB SELECT IN + 2 COM LOSS gi POWER-LIMITED I +o DISABLE 1 &SUPERVISED + o•er IDC 5 DISABLE 2 1 + g FROM PANEL OR PREVIOUS —�_•__- + DEVICE K ' I J TO NEXT v 411110 411111■4111■411111,411110 ■ , DEVICE / 4111 COMMUNICATION LINE,32 VDC MAX. SEE PANEL MANUAL FOR WIRE RESTRICTIONS. 52747w2.wmf + m p CONNECT MODULES I + IDC 1 FIGURE 2: TO LISTED COMPATIBLE +m o CONTROL PANELS ONLY. --= 1 + Typical Fault-Tolerant + ti a Initiating Device Circuit IDC 2 I + s Configuration — + a,o Class A, Style D. _ NOTE:Any number of UL-Listed contact + In closure devices may be used. DO NOT T — 1 + 4 IDC3 MIX fire alarm initiating and supervisory + v o devices on the same initiating device cir- + - cult. install contact closure devices per + e,,0 manufacturer's installation instructions. IDC4 I + Q + N`6' CLASS A IDC(TYPICAL) + H C SELECT m DISABLE 1 POWER-LIMITED IDC 5 I + ° DISABLE 2 ii &SUPERVISED +to 0 , + - FROM PANEL REMOVE SHUNT OR PREVIOUS �+ , + FOR CLASS A. DEVICE - ����,�� • i 0 TO NEXT > ����� . , N DEVICE / COMMUNICATION LINE,32 VDC MAX. SEE PANEL MANUAL FOR WIRE RESTRICTIONS. Page 2 of 2 — DF-52347•07/14/04 July 14,2004 DF-52130 E-350 CMF (A) and CRF (A) Series Fl reliTev ALarrns Addressable Control and Relay Modules www.firelite.com Section: Addressable Devices GENERAL CMF-300 Control Module (Replaces C304) L California State Fire 1111110111111°. The CMF-300 Addressable Control Module provides � :+ �` Marshal Fire•Lite Alarm's MS-9200, MS-92000D, and MS-9600 in- 7300-0075:185 telligent control panels a supervised Class B (Style Y) or LISTED APPROVED Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF to be acti- S2424 vated, either manually or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 4s configured as a relay) s§ CONTROL $mss` • The CRF-300 Addressable Relay Module provides the • m>w t MS-9200, MS-92000D, and MS-9600 systems with two ,4-' isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door holders, control equipment, etc. Addressability allows the III it dry contact to be activated, either manually or through panel • � �'.� 11'0 programming, on a select basis. 3i+�; j f= FEATURES +i.II - I-� • Built-in type identification automatically identifies these kfp 111';‘., devices to the control panel. . • Internal circuitry and relay powered directly by two-wire — ".an SLC loop. The CMF module requires power (for horns, strobes, etc.). 4101 LL • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. CMF-300 and CRF-300 Module • High noise immunity (EMF/RFI). OPERATION • The CMF may be used to switch 24 volt NAC power. Each CMF or CRF uses one of 99 (MS-9200/MS-92000D) • Wide viewing angle of LED. or 159 (MS-9600) possible module addresses on a SLC • SEMS screws with clamping plates for wiring ease. loop. It responds to regular polls from the control panel • Direct Decade 01-99 (MS-9200/MS-92000D) and 01- and reports its type and status, including the open/normal/ 159 (MS-9600) entry of address. short status of its Notification Appliance Circuit(NAC). The APPLICATIONS LED blinks with each poll received. On command, it acti- APPLICATIONS its internal relay. The CMF supervises Class B (Style The CMF is used to switch 24 VDC audible/visual power. Y) or Class A (Style Z) notification or control circuits. The CRF may be programmed to operate dry contacts for Upon code command from the panel, the CMF will discon- door holders, Air Handling Unit shutdown, etc. nect the supervision and connect the external power sup- CONSTRUCTION ply in the proper polarity across the load device. The dis- connection of the supervision provides a positive indica- • The face plate is made of off-white Noryl®. tion to the panel that the control relay actually turned ON. • Controls include two rotary switches for direct-dial entry The external power supply is always relay isolated from of address (01-99 on the MS-9200, MS-92000D, and 01- the communication loop so that a trouble condition on the 159 on the MS-9600). external power supply will never interfere with the rest of • The CMF is configured for a single Class B (Style Y) or the system. Class A (Style Z) Notification Appliance Circuit. Rotary switches set a unique address for each module. • The CRF provides two Form-C dry contacts that switch The address may be set before or after mounting. The together. built-in TYPE CODE (not settable) will identify the module Noryl®is a registered trademark of GE Plastics, a subsidiary of to the control panel, so as to differentiate between a mod- General Electric Company. ule and a sensor address. Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep 1S0 9001 our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to C E RT I F I E o change without notice. ENGINEERING d MANUFACTURING For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, QUALITY SYSTEMS Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-52130•07/14/04 — Page 1 of 2 SPECIFICATIONS FOR CMF RELAY CONTACT RATINGS Normal operating voltage: 15 to 32 VDC. for both CMF and CRF models Maximum current draw: 5.1 mA (LED on). Load Description Application Maximum Current Average operating current: 390 pA (LED flashing). Voltage Rating External supply voltage (between Terminals T3 and T4): Resistive Non-Coded 30 VDC 3.0 A maximum 80 volts (RMS or DC). Resistive Coded 30 VDC 2.0 A Drain on external supply: 2 mA maximum (using internal Resistive Non-Coded 110 VDC 0.9 A EOL relay). Resistive Non-Coded 125 VAC 0.9 A EOL resistance: 47K ohms. Inductive(UR=5 ms) Coded 30 VDC 0.5 A Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Inductive(UR=2 ms) Coded 30 VDC 1.0 A Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm)wide x kxiuctive(PF=0.35) Non Coded 125 VAC 0.5 A 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm)square 6724 rate.tbl x 2.125" (53.975 mm) deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25"(31.75 mm)deep. Mounts to a 4"(101.6 mm)square x 2.125" (53.975 mm) deep box. PRODUCT LINE INFORMATION CMF-300 Intelligent Addressable Control Module. /\ CMF-300(A) Same as above with ULC listing. CRF-300 Intelligent Addressable Relay Module. e:41144144111\4446..., I CRF-300(A) Same as above with ULC listing. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier — required by UL for separating power-limited and non-power lim- ited wiring in the same junction box a s I _ CMF-300. 7 '1 MOUNTING —,,, - :a o DIAGRAMS ■ 2 ' i -� Note CB500 Module .4( which creates isolated quadrant. 1 � � 1 i B CB500---=--.),. t1 J/ s.'4 -; ° C� E \�3 1J / I',1 o0 E°47/01 IQ) IC) (1- e• PI. ISOLATED a�a QUADRANT m \ �� % °� 4"(101.6 mm)square x 2.125"(53.975 mm)deep box Page 2 of 2 — DF-52130•07/14/04 July 8, 2004 DF-52301 •D-025 r:44 Flre•LITe' ALarms FCPS-24FS6 24 Volt, 6 Amp Remote Power Supply www.firelite.com Section: Power Supplies/Accessories GENERAL _. California The FCPS-24FS6 is a 6-amp cost-effective,compact, re- State Fire P P �Lo�°; Marshal mote power supply with battery charger. The FCPS-24FS6 APPROVED _ 7315 0075:206 may be connected to any 12-or 24-volt Fire Alarm Control I ) Panel (FACP) or may stand alone. Primary applications LISTED M EA include Notification Appliance (bell) Circuit (NAC) expan- S2424 sion (to support ADA requirements and NAC synchroniza- 219-02-E Lion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B(Style Y)or Class A(Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. __ FCPS.7455 FEATURES • UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. W • Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. • Operates as a sync follower or a sync generator(default). * See note on reverse side. • Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone mode]). • Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300)for alarm activation. • Four ClassB(StyleY)orfourClassA(StyleZ)(withZNAC • AC trouble report selectable for immediate or 8 hour 4 Module) Notification Appliance Circuits. delay. • 6.0 A full load output(3.0 A maximum per circuit)in NAC • Works with virtually any UL 864 fire alarm control which expander mode (UL 864). utilizes an industry-standard reverse-polarity notifica- • 4.0 A continuous output in stand-alone mode(UL 1481). Lion circuit (including unfiltered and unregulated bell • In stand-alone mode, output power circuits may be power). configured as resettable(reset line from FACP required) • Requires input trigger voltage of 9.0-32 VDC. or non-resettable or a mix of two and two. • Self-contained in compact, lockable cabinet (15" [38.1 • Fully regulated and filtered power output (optimal for cm] H x 14.5"[36.8 cm]W x 2.75"[7.0 cm] D). powering four-wire smoke detectors, annunciators and • Includes integral battery charger capable of charging up other system peripherals requiring regulated/filtered to 18 AH batteries. Cabinet capable of housing 7.0 AH power). batteries. • Power limiting technology meets UL power limiting re ▪ Battery charger may be disabled via dip switch for appli quirements. cations requiring larger batteries. • Form-C normally closed trouble relay. • Fixed, clamp-type terminal blocks accommodate up to • • • Fully supervised power supply, battery and Notification 12 AWG(3.1 mm2)wire. Appliance Circuits. • Selectable earth fault detection. This•document Alarms is a to Honeywell to company. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. C E RT I FE E D For more information, contact Flre•Llte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING 8 MANUFACTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52301 07/08/04 — Page 1 of 2 STANDARDS and CODES Example 2 The FCPS-24FS6 complies with the following standards: Use the FCPS-24FS6 to expand auxiliary regulated 24 volt • NFPA 72 National Fire Alarm Code. system power up to 4 amps. Both non-resettable and • UL 864 Standard for Control Units for Fire Alarm Sys—resettable power options are available. tems (NAC expander mode). Resettable outputs are created by connecting the resettable • UL 1481 Power Supplies for Fire Alarm Systems output from the FACP to one or both of the FCPS-24FS6 (stand-alone mode). inputs. Example 3 SPECIFICATIONS Use addressable control modules to activate the FCPS- Primary(AC) Power 24FS6 versus the FACP Notification Appliance Circuits. This • FCPS-24FS6: 120 VAC 60 Hz,3.2 A maximum typically allows for mounting the FCPS-24FS6 at greater • Wire size:minimum 14 AWG(2.0 mm2)with 600V insu- distances* away from the FACP while expanding system lation. architecture in various applications. Control Input Circuit In this example, an addressable control module is used to • Trigger Input Voltage: 9.0 to 32 VDC. activate the FCPS-24FS6 and an addressable monitor • Trigger Current: 2.0 mA(16-32 V). module is used to sense FCPS-24FS6 trouble conditions. (per input) 1.0 mA(9-16 V). Local auxiliary power output from the FCPS-24FS6 pro- Trouble Contact Rating vides power to the addressable control module. • 5.0 A at 24 VDC. Auxiliary Power Output •Fire•Lite's MS-9200, MS-92000D, (198-poInt)or MS-9600 (636- • Specific Application Power- 500 mA maximum, point)addressable FACPs have the capability of locating control and monitor modules up to 10,000 feet(3048 m)away. Output Circuits • +24 VDC filtered, regulated. Sync Follower/Generator Note: In some installations, it • 3.0 A maximum for any one circuit. is necessary to synchronize the flash timing of all • 4.0 A maximum total continuous current for all outputs strobes in the system for ADA compliance. Strobes (Stand-alone mode). accomplish this by monitoring very short timing pulses • 6.0 A maximum total short-term current for all outputs on the NAC power,which are created by a Fire Alarm (NAC Expander mode). Control Panel such as the Fire•Lite MS-9600. When Secondary Power(Battery)Charging Circuit installed at the end of a MS-9600 NAC wire run, this • Supports lead-acid batteries only. power supply can track (i.e. "follow")the strobe synchro- • Float Charge Voltage: 27.6VDC. nization timing pulses on the existing NAC wire run. This • Maximum Charge Current: 1.5 A. maintains the overall system flash timing of the addi- • Maximum Battery Capacity: 18 AH. tional strobes attached to this power supply. ORDERING INFORMATION When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs FCPS-24FS6 Remote charger power supply (120 track the strobe synchronization pulses present at this VAC). Includes main printed circuit supply's sync input terminal. The pulses are originated board, transformers, red enclosure, and from an upstream FACP or other power supply. installation instructions. When this power supply is configured (via DIP switch settings) as a "sync generator,"this supply's sync input FCPS-2456RB Replacement mother board. terminal are not used. Rather, this power supply is the PN 90286 FCPS-24F Module Mounting Kit originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode, ZNAC-4 Class A(Style Z) NAC option module the sync type(System Sensor,Wheelock,or Gentex)is A77-716B 12/24 VDC end-of-line relay for selectable via DIP switch settings. monitoring 4-wire smoke detector power. BAT-1270 Battery,12 volt,7.0 AH(two required). APPLICATIONS Example 1 Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B(Style Y)outputs or 4 Class A (Style Z)outputs(using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 — DF-52301 07/08/04 July 14,2004 DF-52176 E-600 D350PL/D35ORPL eb FI reLTe' ALarms Intelligent Addressable Photoelectric Duct Smoke Detector www.firelite.com Section: Addressable Devices GENERAL _ California The new Fire•Lite Alarms D350PL and D35ORPL addres- State Fire sable photoelectric duct smoke detectors are used exclu- 0 Marshal sively with the Fire•Lite MS 9200, MS 92000D and MS �— :I 3240-0075:189 1111111011°. 9600 addressable fire alarm control panels. Since these LISTED APPROVED duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, po- S1059 tentially saving precious rescue time while also reducing property damage. The D35ORPL offers the same features as the D350PL while adding a Form-C relay. i�,. , .. An HVAC system supplies conditioned air to virtually every "; area of a building. Smoke introduced into this air duct sys- � tst -.�''�• tem is thus distributed to the entire building. Smoke detec- ,= r :I tors for use in air duct systems sense the presence of smoke '...N—, ^ "y �! in the duct. ' The D350PL and D35ORPL air duct smoke detectors are `.'; 1 , I .✓ o photoelectric detectors, combining this detection technol- , ; l - ogy with an efficient housing design that samples air pass- 1,_ . D350PL ing through the duct, allowing detection of a developing hazardous condition. When sufficient smoke is sensed, `��'r an alarm signal is initiated at the fire control panel moni- toring the detector. With the D35ORPL, appropriate action Smoke detectors and alarm system control panels have can be taken to shut off fans and blowers and to change specifications for Signaling Line Circuit (SLC) wiring. Con- over air handling systems, etc.This can isolate toxic smoke suit the control panel specifications for wiring requirements and fire gases or prevent their distribution thoughout ar- before wiring the detector loop. The D350PL/D35ORPL eas served by the duct system. detector is designed for ease of wiring; the housing pro- Two LED's on each detector light to provide a local, visible vides a terminal strip with clamping plates. alarm indication. A remote alarm output is provided for use Remote LED annunciator capability is available as an op- with auxiliary devices. The D350PL and D35ORPL have tion. Each duct smoke detector can only be wired to one re- remote test capability with the RTS451/RTS451KEY Re- mote accessory. mote Test Station, as well as remote communication us- ing the RA400Z alarm LED. SPECIFICATIONS APPLICATIONS D350PL (A) Operating voltage range: 15 to 32 VDC. Duct smoke detectors have the following limitations: Standby current: 300 pA @ 24 VDC (one communication • NOTasubstituteforopenareasmokedetectors. every 5 seconds with LED blink enabled). • NOT a substitute for early warning detection. • NOT a replacement for a building's regular fire detection Operating temperature range: 32°to 131°F(0°to 55°C). system. Humidity range: 10%to 93% (non-condensing). Duct air velocity: 100 to 4,000 feet/min. (152.4 to 1219.2 Call your Fire•Lite Alarms distributor for a copy of System meters/min.). Sensor's application guide, Proper Use of Smoke Detec- Dimensions: 14.375" (365.125 mm)wide x 5.500" (13.970 tors in Duct Applications (A05-1004-00) or visit www.systemsensor.com mm)high x 2.750"(69.850 mm)deep. • Options: RTS451, RTS451KEY, RA400Z. Separate auxil- INSTALLATION iary power not required. Wiring: For signal wiring (the wiring between detectors or D35ORPL (A) from detectors to auxiliary devices), it is recommended that Operating voltage range: 15 to 32 VDC (comm. line volt- single conductor wire be no smaller than 18 AWG(0.75 mm2). age)and 24 VACNDC or 120/240 VAC auxiliary power(sepa- The duct smoke detector terminals accomodate wire sizes rate source). NOTE: The D35ORPL (A) requires a sepa- up to 12AWG (3.25 mm2). Flexible conduit is recommended rate auxiliary source. for the last foot(30.48 cm)of conduit:solid conduit connec- tions may be used if desired. This• document Alarms is a Honeywell company. DSO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. C E R T I F I E tD For more information, contact Fire•Llte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING A MANUFACTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS OF-52176•07/14/04 — Page 1 of 2 Standby current: 300 pA @ 24 VDC (one communication PRODUCT LINE INFORMATION every 5 seconds with LED blink enabled). D350PL Addressable duct detector housing with Auxiliary power current draw (@ 24 VDC): 26 mA photolectric smoke detector. (standby), 87 mA (alarm). D350PL (A) Same as above with ULC listing. Operating temperature range: 32°to 131°F (0°to 55°C). D35ORPL Addressable duct detector housing with Humidity range: 10% to 93% (non-condensing). photolectric smoke detector and DPDT Duct air velocity: 100 to 4,000 feet/min. (152.4 to 1219.2 relay. meters/min.). D35RPL (A) Same as above with ULC listing. Dimensions: 14.375" (365.125 mm)wide x 5.500" (13.970 ST-1.5 Metal sampling tupe, duct widths 1' to 2' mm)high x 2.750"(69.850 mm)deep. (see table at left for metric lengths). Options: RTS451, RTS451KEY, RA400Z.APA451. ST-3 Metal sampling tupe, duct widths 2' to 4'. ST-5 Metal sampling tupe, duct widths 4' to 8'. Relay contact ratings:2 Form-C, DPDT, 10 A @ 250 VAC, ST 10 Metal sampling tupe, duct widths 8'to 12'. 10 A @ 30 VDC (resistive). Minimum switching current of 100 mA @ 5 VDC. RA400Z Remote annunciator alarm LED. RTS451 Remote test station. Mounts in single-gang INLET TUBE SELECTION box. Includes red alarm LED and magnet test switch. RTS451KEY Key-activated remote test station. Outside Duct Width Inlet Tube* F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. Up to 2 feet(0.6096 m) ST-1.5 S08-39-01 Replacement photo insect screen. P48-55-00 Replacement end cap for plastic sampling tube. 2 to 4 feet(0.6096 to 1.2192 m) ST-3 P48-21-00 Replacement end cap for metal sampling tube. 4 to 8 feet(1.2192 to 2.4384 m) ST-5 A5053FS Replacement photoelectric sensor board. A5067 Replacement power board (without relay). 8 to 12 feet(2.4384 to 3.6576 m) ST 10 A5060 Replacement power board (with relay). *NOTE: Inlet tube is required and must be purchased separately.Order one inlet tube for each duct smoke detec- tor ordered. Page 2 of 2 — DF-52176•07/14/04 DF-52004:A1 •F-050 BG-1 2 Series eiht>0 Flre•LrreSAtarms Manual Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices General The Fire-Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and 11-1-F I 14E 1 end-user in mind. The BG-12 Series features a variety of mod- els including single-and dual-action versions. The BG-12 Series provides Fire•Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a man- PUSH IN ual alarm initiating input signal. Its innovative design, durable PULL DOWN construction, and multiple mounting options make the BG-12 Series simple to install, maintain,and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull-force. �jreltre _ g • Meets UL 38,Standard for Manually Actuated Signaling Boxes. %.4 j * • Easily operated(single- or dual-action), yet designed to pre- vent false alarms when bumped,shaken,or jarred. • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. Construction • The word "ACTIVATED" appears on top of the handle in • Cover, backplate and operation handle are all molded of bright yellow,further indicating operation of the station. durable polycarbonate material. • Operation handle features white arrows showing basic opera- • Cover features white lettering and trim. lion direction for non-English-speaking persons. Red color matches System Sensor's popular SpectrAlert® •• Braille text included on finger-hold area of operation handle Advance horn/strobe series. and across top of handle. • Multiple hex-and key-lock models available. Operation • U.S. patented hex-lock needs only a quarter-turn to lock/ unlock. The BG-12 manual pull stations provide a textured finger-hold • Station can be opened for inspection and maintenance with- area that includes Braille text. In addition to PUSH IN and PULL out initiating an alarm. DOWN text, there are arrows indicating how to operate the sta- • Product ID label viewable by simply opening the cover; label lion,provided for non-English-speaking people. is made of a durable long-life material. Pushing in and then pulling down on the handle activates the • The words"NORMAL"and"ACTIVATED"are molded into the normally-open alarm switch. Once latched in the down position, plastic adjacent to the alarm switch(located inside). the word"ACTIVATED"appears at the top in bright yellow,with a • Four position terminal strip molded into backplate. portion of the handle protruding at the bottom as a visible flag. • Terminal strip includes Phillips combination head captive 8/32 Resetting the station is simple: insert the key,twist one quarter- screws for easy connection to Initiating Device Circuit(IDC). for d then ra open io the station's front cover,original position.the n. The loaded operation handle to return to its original position. The • Terminal screws backed-out at factory and shipped ready to alarm switch can then be reset to its normal(non-alarm)position accept field wiring(up to 12 AWG/3.1 mm2). manually(by hand) or by closing the station's front cover, which • Terminal numbers are molded into the backplate, eliminating automatically resets the switch. the need for labels. • Switch contacts are normally open. • Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang,or 4"(10.16 cm)square electrical box. • Backplate is large enough to overlap a single-gang backbox cutout by 1/2"(1.27 cm). • Optional trim ring(BG12TR). • Spanish versions(FUEGO)available(BG-12LSP,BG-12LPSP). • Designed to replace the Fire•Lite legacy BG-10 Series. • Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. DF-52004:A1 •04/22/09—Page 1 of 2 Specifications Agency Listings and Approvals PHYSICAL SPECIFICATIONS: The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult pull station SB-I/O sB-10 factory for latest listing status. Height 5.5 inches 5.601 inches 5.5 inches • C(UL)US:S711 (13.97 cm) (14.23 cm) (13.97 cm) • FM Approved Width 4.121 inches 4.222 inches 4.121 inches • CSFM:7150-0075:184 10.47 cm) (10.72 cm) (10.47 cm) ) ( ) ( ) • MEA:67-02-E Depth 1.39 inches 1.439 inches 1.375 inches • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; (3.53 cm) (3.66 cm) (3.49 cm) 52004Aim tbl 6,632,108. ELECTRICAL SPECIFICATIONS: Product Line Information Switch contact ratings:gold-plated;rating 0.25 A @ 30 VAC or BG-12S: Single-action pull station with pigtail connections, hex VDC. lock. ENGINEERING/ARCHITECTURAL SPECIFICATIONS BG-12SL: Same as BG-12 with key lock. Manual Fire Alarm Stations shall be non-code, with a key- or BG-12: Dual-action pull station with SPST N/O switch, screw hex-operated reset lock in order that they may be tested,and so terminal connections, hex lock. designed that after actual Emergency Operation,they cannot be BG-12L: Same as BG-12 with key lock. restored to normal except by use of a key or hex. An operated BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ station shall automatically condition itself so as to be visually FUEGO)labeling. detected as activated. Manual stations shall be constructed of BG-12LOB: Same as BG-12L with "outdoor use" listing. red colored LEXAN (or polycarbonate equivalent) with clearly Includes outdoor listed backbox,and sealing gasket. visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, BG-12LO: Same as BG-12L with "outdoor use" listing. Does 1.00 inches (2.54 cm) or larger. Stations shall be suitable for not include backbox. surface mounting on matching backbox SB-10 or SB-I/O; or BG-12LA: Same as BG-12L with auxiliary contacts. semi-flush mounting on a standard single-gang,double-gang,or BG-12LPS: Dual-action pull station with pre-signal option. 4" (10.16 cm)square electrical box, and shall be installed within BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ the limits defined by the Americans with Disabilities Act(ADA)or FUEGO)labeling. per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. SB-10: Surface-mount backbox,metal. NOTE: The words"FIRE/FUEGO"on the BG-12LSP shall appear SB-I/O: Surface mount backbox, plastic. (Included with BG on the front of the station in white letters, approximately 3/4" 12L08.) (1.905 cm)high. BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys,set of two.(Included with key-lock pull stations.) 17007: Hex lock,9/64". (Included with hex-lock pull stations.) NOTE: For addressable BG-12LX models, see data sheet DF- 52013. FUEGO/FIRE JEMPUJE Y r PUSH IN Jr HALE HACIA ABAJO PULL DOWN • f ti I � FIre•LIT9! ) Fire•Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTIFIED We cannot cover all specific applications or anticipate all requirements. EMINEB1IN6I MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52004:A1 •04/22/08 July 14,2004 DF-52384•E-160 SD355(A)/ SD355T(A) FIre•LITe''ALarms Addressable Photoelectric Smoke www.firelite.com Detectors Section: Addressable Devices GENERAL = California State Fire The Fire•Lite Alarms SD355 and SD355T addressable, Marshal low-profile plug-in photoelectric detectors use a state-of- .. -: 7272-0075:194 the-art photoelectric sensing chamber with communica- tions to provide open area protection and are used exclu- LISTED sively with Fire•Lite's MS-9200,MS-92000D,and MS-9600 S1059 M EA 41t* Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are APPROVED addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving pre- cious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible �t sy rA t �rc� sensor indication. Remote LED annunciator capability is _ i„ available as an optional accessory (P/N RA400Z). ? �'�•" ��s, s FEATURESY � SLC loop: z.r N ri+trfl 4 i• • Two-wire loop connection ° ¢ °s• • Unit uses base for wiring, detector head plugs-in. 69344ho,,pg Addressing: SD355 with • Addressable by device. B350LP base • ..,t � • Direct Decade 01 –99 (MS-9200, MS-920000) and 01 . – 159 (MS-9600) entry of address. " , � � > Architecture: tf,,€.44 a, • Unique single-source, dual-chamber design to respond : 6935"1.jpg ,.h. quickly and dependably to a broad range of fires. SD355T with —"-,- • Sleek, low-profile design. B350LP base • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. Other system features: Operation: • Fully coated circuit boards and superior RF/transient pro- • Withstands air velocities up to 1,500 feet-per-minute(7.6 tection. m/sec.) without triggering a false alarm. • Factory preset at 1.5%nominal sensitivity for panel alarm • 94-VO plastic flammability rating. threshold level. • Low standby current. • Visible LED "blinks" when the unit is addressed (corn- Options: municating with the fire panel)and latches on in alarm. • Remote LED output connection (P/N RA400Z). Mechanicals: APPLICATIONS • Sealed against back pressure. Use photoelectric detectors in life-safety applications to pro- • Direct surface mounting or electrical box mounting. vide a broad range of fire-sensing capability, especially • Mounts to:single-gang box,3.5"(8.89 cm)or4.0"(10.16 where smoldering fires are anticipated. Ionization detec- cm)octagonal box, or 4.0" (10.16 cm) square electrical tors are often better than photoelectric detectors at sens- box (using a plaster ring—included). ing fast, flaming fires. This•document Alarms is a to Honeywell to company. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. CERTIFIED For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING 8 MANUFACTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52384•07/14/04 — Page 1 of 2 CONSTRUCTION PRODUCT LINE INFORMATION These detectors are constructed of off-white LEXAN®. NOTE: A"suffix indicates ULC-Listed model. SD355(T)plug-in,low-profile smoke detectors are designed SD355 Addressable photoelectric detector(B350LP to commercial standards and offer an attractive appear- base included). ance. SD355A Same as SD355 with ULC Listing (8350LPA LEXAN®is a registered trademark of GE Plastics,a subsidiary of base included). General Electric Company. SD355T Same as SD355 but with thermal element INSTALLATION (B350LP base included). SD350(T)plug-in detectors use a detachable mounting base SD355TA Same as SD355T with ULC Listing(8350LPA to simplify installation, service and maintenance. Mount base included). base on box which is at least 1.5 inches (3.81 cm) deep. RA400Z(A) Remote LED. Mounts to a single-gang box. Suitable boxes include: B350LP(A) Plug-in detector base (included). Dimen- • 4.0" (10.16 cm)square box with plaster ring. sions:6.1"(15.5 cm).Mounting:4.0"(10.16 • 4.0" (10.16 cm)octagonal box. cm) square box with or without plastic ring, • 3.5" (8.89 cm)octagonal box. 4.0"(10.16 cm)octagonal box,3.5"(8.89 cm) • Single-gang box. octagonal box,or single-gang box.All mount- ing boxes have a minimum depth of 1.5"(3.81 NOTE:Because of the inherent supervision provided by the SLC cm). loop, end-of-line resistors are not required. Wiring "T-taps"or branches are permitted for Style 4 (Class B) wiring only. B224RB(A) Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" OPERATION (10.16 cm)square box with or without plastic Each SD355(T)uses one of 99 possible addresses on the ring, 4.0" (10.16 cm) octagonal box, or 3.5" MS-9200 and MS-92000D Signaling Line Circuit(SLC),or (8.89 cm)octagonal box.All mounting boxes up to 318 (159 on each loop)on the MS-9600 SLC. It re- have a minimum depth of 1.5" (3.81 cm). sponds to regular polls from the system and reports its type B224BI(A) Intelligent isolator base, isolator SLC from and status. shorts on the loop. The SD355(T) addressable photoelectric sensor's unique B501BH(A) Plug-in System Sensor sounder detector unipolar chamber responds quickly and uniformly to a broad base.Diameter:6.0"(15.24 cm).Mounting: range of smoke conditions and can withstand wind gusts 4.0" (10.16 cm) square box with or without up to 1,500 feet-per-minute (7.6 m/sec.) without sending plastic ring. Mounting box has a minimum an alarm level signal.Because of its unipolar chamber,the depth of 1.5" (3.81 cm). SD355(T)is approximately two times more responsive than B501 BHT(A)Same as 8501 BBH(A), but includes tempo- most photoelectric sensors. This makes it a more stable ral sounder. detector. Accessories: DETECTOR SENSITIVITY TEST RA400Z(A) Remote LED annunciator. 3 - 32 VDC. Fits Each detector can have their sensitivity tested (required U.S. single gang electrical box. For use with per NFPA 72, Chapter 7 on Inspection, Testing and Main- 8501(A) and B350LP(A) bases only. tenance) when installed/connected to an MS-9200, MS- SMK400 Surface mounting kit provides for entry of 92000D,or MS-9600 addressable fire alarm control panel. surface wiring conduit. For use with 8501(A) The results of the sensitivity test can be printed off the MS- base only. 9200, MS-92000D, or MS-9600 for record keeping. RMK400 Recessed mounting kit.For use with 8501(A) base only. SPECIFICATIONS M02-04-01 Test magnet. Voltage range: 15-32 VDC(peak). XR-2 Detector removal tool.Allows installation and/ Standby current:300 pA @ 24 VDC. or removal of detector heads from bases in LED current:6.5 mA @ 24 VDC(latched"ON"). high ceiling applications. Air velocity: 1,500 ft./min.(7.6 m/sec.)maximum. XP-4 Extension pole for XR-2.Comes in three 5-ft. Diameter: 6.1" (15.5 cm) installed in B350LP base. (1.524 m) sections. Height: 2.1"(5.33 cm)installed in B350LP base. Weight:3.6 oz. (102 g). Operating temperature range: for SD355: 0°C to 49°C (32°F to 120°F)SD350; for SD355T:0°C to 38°C(32°F to 100°F). Temperature: 0°C-49°C(32°F- 120°F). Relative humidity: 10%-93%,non-condensing. Page 2 of 2 - DF-52384•07/14/04