Loading...
Plans 0 0 'Ai VD jjVE )itiL X2013 6) ° � * a II IaI01� 0 p co s = CITY E 6) ......:....;..: p Ifs` TENANT IMPROVEMENT d v�' ems(^u, �' › ,f, O TRIANGLE III _11‘ .„..,, k„ . 2 ID g °fig 13221 SW 68TH PARKWAY ,_,..,‘ cF ci cc 0 . ,,, - . _ ,,.. ,, or, .. „, ,.. — \--. TIGARD OREGON , „. . „, . . n • .O , ,,.. . . ,.. . -6 -6 ,.., 3 ilt 2 1 ' Client �jp�} v1 . '�. ir) .I INDEX >, :3 w 2010 OSSC SECTION 107.3.4.2 (by separate permit) CC T1.0 CODE SUMMARY PLAN AND NOTES Y ) FIRE SPRINKLER ► EXISTING WALL TO REMAIN A2.1 PARTIAL FIRST FLOOR PLAN, REFLECTED CEILING PLAN, KEY PLAN AND NOTES I & ALARM ,F 0 A8.1 DETAILS AND ELEVATIONS E” MECHANICAL NEW WALL TO UNDERSIDE OF GRID, SEE 2/A8.1 A9.1 SCHEDULES ELECTRICAL fi co -4 ,...- >..fm. - ' EXISTING 1 HOUR RATED WALL TO REMAIN PLUMBING SCOPE OF WORK EXIT ILLUMINATION EXISTING DEMISING WALL TO REMAIN Project THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN PRECOA FOR AN APPROXIMATELY 4,102 SQUARE FOOT TENANT ON THE FIRST OF FIVE FLOORS. OF THESE SYSTEMS COMPONENTS. THESE SYSTEMS COMPONENTS SHOWN ON DOCUMENTS �C�T REQUIRED EXIT SUITE 120 WORK TO INCLUDE NEW WALLS, DOORS, AND CASEWORK. SYSTEMS/COMPONENTS. /. ARE SCHEMATIC ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT '- DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW /0„;;;/,/,,, TENANT APPROVAL: PRIOR TO SUBMITTAL NOT IN SCOPE OF WORK • MANGLE 111 13221 SW Tai PARKWAY ADA IMPROVEMENTS RD, OF 97223 DESIGN/CODE 1 1 VALUATION OF WORK = $55,000 GOVERNING CODE: 2010 OSSC 25% VALUATION FOR UPGRADE = $13,750 OD OCCUPANCY: B ADA UPGRADE = BUILDING IS FULLY COMPLIANT � 3041 � CONSTRUCTION TYPE: TYPE 1--B `E E ': .LTO TENANT AREA (APPROX): APPROX. 4,102 S.F. i �; CI OCCUPANCY LOAD: 42 tpiPORTEAND, OREGON ,, . 1 REQUIRED EXIT, 2 EXITS PROVIDED .t )' ''47)4*) 40 ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION THROUGHOUT OF 0 WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER 1 GROUP MACKENZIE 2Q13 ALL RIGHTS RESERVED __ _ THESE DRAWINGS ARE THE PROPERTY OF��` l GROUP MACKENZIE AND ARE NOT TO BE i _ ~ , F USED OR REPRODUCED IN ANY MANNER, ...-7--. a - =' , �" _ e„....�_-,---==--�- WITHOUT PRIOR WRITTEN PERMISSION ■■ �i/srEJ�� �Jie�tiilliy Fri""—°Y"!'iii��alii"��J=��[a r -- - I, ..w.. •;W:V: Wray Ai .fa.Lr.� C_7 r f. / 7 ��R�.P�.�; i]� �.IS�L��w—�� J ii�+i�La i�5�P1��SYi iii � � s ��. 1� � f � r� � , r� REVISIONS: _ � �: � gyp,{ � �� Z � f I __. —,.�, _ –_� , ..__ S.W. IRVIN in V REVISIONS REVISION DEETA r�' -- G ST. - > THIS CLOSING OATS Il /•/� ' / 7 ` � � �---�� i o 111 SHEET 1$ / At/i/ --�� � r a ,/ / /// , \ 11 / /42 / / 7-/: < ////, / / / v \ i C , , , 1PJIIr �1 r / 3 all 44W: 1 41 X ir 1 r i..„ IF . .--,..- - . ' ' . „„<„4"...--...., 7,_ N N Ce'' '\ , 1 7/./ 1 1111------- ._--- CITY l� �'IGA 49 _��___: TRIANGLE E 413k r', . 4 . '''. 1 --- I droved.....�.�.�i_�.�.�=.f,f.�`>�.f=.=�. C, " 1 d J • SHEET TITLE:Pv.di�;--- -, _ COIO�A anditianall A oved 1 �� 1.■f + // Y n CODE UMM Y � .rte . _ . - .�_ ------�_ - -/�% See Metter to:Fad lo`� � �A& i PLAN AND „:„„4/ >� I PARK f �� j BUILDING III � 04- r i 1 1°' 3y > _ _r-�. I, �i / �,F' ��/1111jt 1• 11 .1 . <+1 1 IP IliperOirrAir L .,..__,OwiAB. — w ww• i ( 1 NOTES Addr , �. II / //// // /r / UM 1 !I 1- / %-n. 4. /V �asedmJ , ;.=-= Occupancy Load To �� _ Construction///II / /// / 1/ / //// miiiiii 4 .,,,,,,=*- Corridor ,,roll 1 tat DRAWN BY HYH, ND ilk � Energy Cody, .-4: .—. ..•x �_�.. —� • --r��. > / ' - —..� „—v+wt it.-n-. .a.r ww.+• ,._.- .- wrxrr.e�w. i._�.�� ...- ..- vs w..s+..�- > - wW. +wr.v a.•+w w«w —� A i n . AL xs:/ / Eh //: ///Addi , -- T- _ _ _ CHECKED BY LFI, PPA Accessibility ',___ ral, __1 I - I, I I COMMON Approved 1 SHEET: ' _ PATH OF NORTH __ I1� _ ,:1 ::;,- .. , 3 „ - __ = EGRESS TRAVEL: 35'-8" , I on site. OFFICE COPS Tia 0 },--,,,,-1--- _ U PLAN I I I',_.� i JOB N0.1 �1.0 1/16„= _0„ 2080243.30, , 1 NORTH PERMIT SET: 06/26/13 208024330\ARCH\30—T1.0.DWG ND 06/25/13 11:30 1:96.00 o o a co . < 5 _1 0,GENERAL NOTES . ., <<? c 1' g 731 fa: oi (u: (I; , �� T. - _� ' u x -- _. °- , ® A. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. © � 3 - 1 3 I I I 'Y 4 ', B. WALL THICKNESS ARE NOMINAL, UNLESS NOTED OTHERWISE. // iiwwmfi3=1'tm7:m..i�rti; iIwu*I if3.,._ Y.:: :..m-;1 #L .W ....... ....:�� _._ .__.i .- ' I I 1 I V I 1 i --b C. COORDINATE ELECTRICAL REQUIREMENTS WITH OWNER, ALL ELECTRICAL DRAWINGS -F-`. ® D co NI . ._ - E 0 _ # .�. 1o3e t OFFICE I COFFEE I I I I I WILL BE BY DEFERRED SUBMITTAL• 1o .7--------,- - I i .,:: 106 g � g 0 I 107 I I I D. ALL NEW INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE• I I I I I �o L �xiy � � � _ - _ E. ALL NEW INTERIOR DOORS TO BE SOLID CORE FLUSH WOOD DOORS TO MATCH BUILDING . L _ ,�_ ,. _ _ .,., fL, a . - w® _p , , ° - - . - 9 STANDARD UNLESS NOTED OTHERWISE. 101A " A6.1 1 F. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE VERIFICATION ,F.`-�.�i \:: v..o.ce w�wsr s.;.wvs r x.emo ,xsva. .A:uk. - 10 � ' a:�m � . u .� � q - HAS BEEN PERFORMED ON 9/15/10. PLAN, ELECTRICAL AND CEILING INFORMATION HAS ` # ` K,, '�� I I I L BEEN UPDATED (OBSERVATION IS LIMITED TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR 0 o 22 l J �,� fg gi L-_ JL-_ J , ,: 1 I I I I TO FIELD VERIFY AND CONFIRM ADDITIONAL REQUIREMENTS WITH OWNER. o•F. �`� I I I I I I I I • G. LOWER VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS .- g 0 > 0 I I L---J I I I I I •! I I OFFICE o � . 4- - - + -- - + - - + - - - -p- - - + - - - -I.-- �� ,,,,. a r,� *-- -E_. - > - e�, , >�. - : 105 Za 1 I I I FINISH PRODUCT PRIOR TO START OF WORK. CONFERENCE -Ii I I I I I I H. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS 0 •0 g 0 I. PATCH AND REPAIR EXISTING WORK DAMAGED DURING CONSTRUCTION TO NEW �, =,, g ® � o 101 � I I I � I 105A ° LU G a0 .Q g I I I I : 1 1 I 1 I di) CONDITION. 'WA% o � 1 I [�. �.� �,�. . �� .� k.,A�. -� �. - _ > k. �. _ .Ax >L �,,.f ,. n Iw ,y. .�,�. u,.. *-- . OPEN �, J. MECHANICAL, ELECTRICAL AND PLUMBING DESIGN/BUILD BY OTHERS °° „i,,,,,"''' (la, 0 ce, CI: L.� ::: : OFFICE 104A K REUSE ALL DEMOLISHED COMPONENTS WHERE POSSIBLE. SERVICE OR REPAIR TO OM a o N 102A 103 TYP:,::,..z.1 .... _.. _.._ w.,a. .xaarw urxa xan.a, +uscs oam w+:ew _�, P sro f / �vd4 h/K tYb(AW :ba6'.' iW � Si✓d:i's t%+4 GO oxmitn 4.Ynaia! fY¢vw •mr'�va Yid a'sy9Y f5stE9Y 4%Y ttal u:+t4n ks:�'uk iY1u'it xawuw .st4+ :::tctaa '«#yM :9.°'V^v iaV6^»aP SSJ.:�O YKLm x»:1u uXW+ E:Oa+a a.B>::b :a:• kn'h'ixr aa:ac0 .. Wwe: mry>+K �d"�.a arov n� At¢'�+% 4croFSO .,.�-..,v._� v6 � � � � PROVIDE IKE NE OPERATION AND APPEARANCE ° � � � LAJ ` ` ` � ` ° - �"' L. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE OR REQUIRED CLEANING ` 0 OFFICE C� c= Q.I I I I I I I I I I I I I THROUGHOUT THE STRUCTURE, DEEMED TO BE THE RESULT OF THEIR WORK. THE , { OFFICE I 1 I 1 I 104 CLEAN UP ALL AREAS AFFECTED BY DUST OR ANY MATERIALS 102 1 p I I I I I I CONTRACTOR WILL CLE MATERIALS, Client -- 41 .4 I I I x° I I I I II I I 1 � _ ., BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT. .. ..1..cx r....m ur ..9 _ er _ _.m w. r _ _ v.�«.an ,J„,. _ .w,... .. n,fF 'i, i �.! ' ' -s. 1 � 1 I 1 I ^ M. ALL DIMENSIONS SHOWN AS PLUS/MINUS (±) ARE FOR GENERAL LAYOUT AND -.-� I l 13 ,.a . ......,i 1 ` •� �1 • 0 a D 1 ;q:>,1 a j°' rt 1 a a 1 .1 -6 as REFERENCE ONLY. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO •,�y x START OF WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO .I 0 0 START OF WORK. yy ' C N. THE CONTRACTOR SHALL COORDINATE MECHANICAL, ELECTRICAL AND FIRE 1 1 I SPRINKLER DRAWINGS WITH ARCHITECTURAL TENANT IMPROVEMENT DRAWINGS. y` 0 i PARTIAL FIRST FLOOR PLAN ADVISE ARCHITECT/DESIGNER PROMPTLY OF ANY CONFLICTS BETWEEN DISCIPLINES. r7: 0. PROVIDE SOUND ATTENUATION BATT AT ALL NEW AND EXISTING WALLS. A2.1 1/8"=l'--0" P. THE CONTRACTOR SHALL SUPPLY ALL ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR ALL OTHER PERMITS. Q. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION OF ALL FURNISHINGS, Project FINISHES, BUILDING STRUCTURE, EQUIPMENT, AND SYSTEMS, AS REQUIRED. PRCOA ,> . R. TENANT DOOR HARDWARE SHALL BE BUILDING STANDARD, IF APPLICABLE, WITH �U 124 )-1,-- = FINISH TO MATCH BUILDING STANDARD• ,T4- s:t" Ff. " h • S. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO LANDLORD FOR .(1 � FUTURE USE. _ a 0 T. SAVE AND RECYCLE DEMOLITION DEBRIS WHERE POSSIBLE• COORDINATE WITH CITY OF TIGARD TRIANGLE III A, X CO )-(-1 + h 4" wx vi ww ff ----i _.w. REQUIREMENTS FOR RECYCLING DEMOLITION DEBRIS. 13221 Vii TAI P KWAY �, j_ j} \7,'kr(? • , I U. SUSPENDED ACOUSTICAL TILE CEILINGS AT 91-0 f (EXISTING) AFF, UNLESS TIGARD, OR. 97223 ./Ni I ' N't, g :I _ -- NOTED it^ V FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT ,� ..� � SEE DETAILS 1/A8.1. L. W. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS - ALL OTHER CEILING PENETRATIONS IN CENTER OF 2x2 PORTION OF ,>� 3041 '�� AND L ' TR P. ,ALTO ._�n„ F----; .:-.... f .".-w�n� 2x4 TILE, UNLESS NOTED OTHERWISE. ;� , : X .X _ � _ X. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. 1.9 \A. _A X Ai ___ Xl '\ H /c\1 _ FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR AND IS •• ki 0 * PORTLAND, OREGON ; -- DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING . . . ,, . n r . . r5. ..._. . . E i INFRASTRUCTURE IN CEILING. '941 :.�.� � Y. EXISTING DAMAGED CEILING GRID AND TILE TO BE REPAIRED OR REPLACE TO LIKE Q�+' CO 1 NEW CONDITION. , '''',X 4. Z. THE CONTRACTOR SHALL CAREFULLY EXAMINE CONSTRUCTION DOCUMENTS FOR THE I x _ T___ F, ,____x T.___, E WORK. ANY CONFLICTS, INCLUDING BUT NOT LIMITED TO BUILT CONDITIONS OF M.E.P. GROUP MACKENZIE 2013 . ;,,,' .,1 X, 3'. . AND FIRE ALARM IN THE PLANS SHALL BE CALLED TO THE ATTENTION OF THE' t, '° �` '� A £ `` ° THESE DRAWINGS ARE THE PROPERTY OF `f V � t„N ,,.. �____� ___, �' - ARCHITECT/DESIGNER PRIOR TO SUBMISSION OF A CAST FOR CONSTRUCTION, S GROUP MACKENZIE AND ARE NOT TO BE ..w ._ . �..__�M.m -__ . -. ww _.. `w"Ww - - - I THAT THE CLARIFICATION CAN BE ISSUED• USED OR REPRODUCE IN ANY MANNER, :;,,z,�;i„>,,,;;, ly- ;�77:�,, 11 ,7 a-- a r ,sy:c.�.; --G o b:7,74- 0 • 1 --a i OMPAM, a- a I WITHOUT PRIOR WRITTEN PERMISSION t REVISIONS: A h T CEILING °in s REVISIONS REVISION DELTA LTA � CLOSING A 8„=1,-o„ SH ET o i . KEYNOTES . i • i LEGEND . i i 1. ALIGN NEW WALL WITH EXISTING WALL OR CORNER. • :: F ; EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING CEILING GRID 2. CENTER NEW WALL WITH EXISTING MULLION, SEE DETAIL 4/A8.1. MODIFY EXISTING . EXIS ING CEILI G ° WINDOW COVERINGS AS REQUIRED. SINK AND PLUMBING. PROVIDE WATERLINE FOR ICE MACHINE. i i �;_---�" 17.*'1 � i 3. NEW UPPER AND LOWER CABINETRY, •1 1 EXISTING WALL TO REMAIN EXISTING 2x4 LIGHT FIXTURE TO REMAIN 4• NEW LOWER CABINETRY WITH COUNTERTOP. ersommilm NEW WALL TO UNDERSIDE OF GRID, SEE 2/A8.1 �� ., F� 5. WORK STATION BY OTHERS. COORDINATE POWER REQUIREMENTS WITH TENANT. SHEET TITLE: t / ' --'- ' ' EXISTING LIGHT FIXTURE TO BE REMOVED/RELOCATED L- -J 1c____JI -, °'. ,.' EXISTING 1 HOUR RATED WALL TO REMAIN. 1><1 , .._.. NEW/RELOCATED 2x4 LIGHT FIXTURE •-"----- .3."� - _ - _-- ----- - ------ --- - -- ---- j r . 4 � F FLOOR bEILING - -w -- -= EXISTING DEMISING WALL TO REMAIN - 1 !NEW/RELOCATED 24 HO2x4 LIGHT FIXTURE R L CT D .._.- ��� ,�-._ _ PLAN, KEY PLAN EXISTING OUTLET AND TELEPHONE/DATA p• PLAN,EXISTING 2'X4' LIGHT FIXTURE TO BE 24-HOUR �� 9® NEW OUTLET AND TELEPHONE/DATA -;kilt .C* .s _. . , _N_ AND NOTES :„ EXISTING 24-HR LIGHT FIXTURE TO REMAIN i 'j` EXISTING COVERPLATE LOCATION TO RECEIVE NEW VOICE/DATA ROUGH IN J1lHh1IUllI \vf ��EXISTING 2'x2' LIGHT FIXTURE TO REMAIN A_._ - _ ,� ..„,,.. „,, �IIilllll l-._.. , _Mil r--"ri, «!9,,, t ;,t,51 EXISTING FLOOR MOUNTED OUTLET TO BE REMOVED 4 _ -. fr I �yz , L-__LLJ -~ �• - ...._ -._. Y �. - - 11111. ? q�:°."i.>ng:-.4.1...- ..-k,-X` k'.>$_: EXISTING RECESSED CAN LIGHT FIXTURE TO REMAIN DRAWN BY: HYH, ND TSC>Y.-" Lf3 ,si ;., .3j i 1.c,A. o �.� y,,.. x� { i^�j C 'gar' �' a • , - lir >�Rj<� Y- :�';-�`�'�'����4���aft � �.� �',a��:'are'"rte:n��y:'-;c:?>. g3>.'.�-� i 3 rc•�`�.A�, i v>n$�>f�n f '>. F '9�'J"'��'�tY�',�r,t.� :ij�a tt_' 1��--.'. :._....Y .� ..r ...i M. y::e`• ^;'c:,4::[::.:�_Y r$il>�„J,�...kAR'.• - ,�t JS>.,:.,�^rE.�J.�k�i�,l%JFr,'.{-T S. �:�v x'45% ..•f:41A "[,!i�..41�..:► TELEPHONE/DATA -._-L, .,..,...:. :.�-., T,:.;._,��...... NEW FLUSH FLOOR MOUNTED OUTLET AND . �._ - .. ,:- ,,.,m i:,, oli r ya:s ;.a{.r:'z:�;ovir ;Nry �; .�, :r, ° �, �. ._.:� y.�4.fay � .� ��.���.;�^�.,.� �, ,�� 1� EXISTING RECESSED CAN LIGHT FIXTURE TO BE REMOVED OR RELOCATED .. _ _ ,,• ..,rl'7` +""'. '".t':�s�i��'[yl'�Jyy K� :a'°�:4. .'�y'�-';lr['{i.;i s-3:.�.3,' v?� �ar;� ✓s 1 t� Y+4a�• -"i` `. 'T,,srT.'' „i 1. r;'E r u,; '�;i:i ,,i'k;`:':,, i.�i>'K,, t ,,, r,. _ ;:f> ;, . MA:,Ya:., r6 .. : "A : �- .... , .. CHECKED BY: LFI, PPA .. < '.l�,{ � n+>:a :,({'ry k`>.' h�N�'i.4.,,, aP a�f%�:�'.+ '�`f idy� ! 5i-,,J..- {��:;;Z'!.•T;4i-t`<>�hc:.3'[i<'>.>?`.ry= 4.: r%t�X°..46,. �...:�,t.s�t :.�`,s; �.�. ^s i-,ti ':%'.-,`-.`,",; .T• •'i1i.. ,;,x;r;�ai �-_-,^*.3"• :,'x,- 'e>tY .ar st'rsir.,,�.7! ,.zl,:, � NEW OR RELOCATED RECESSED CAN LIGHT FIXTURE �I <'.:.�,�,. �:�s�x.:�,��,.�:,�;�.o,{..�y..�• ....�f�,:: ._�;�°-.,4. ,��-;�.�;_;�,;,�• EXISTING BASE FEED ,3;' k .- ......_.�� , ,15";::�Z'.:F R 1d ,f a";a ,x��'L�5'S>�`yy P.4 �{�¢. aC'{�,'. `:: >Lj, ,,,; �s4," 's�;•, ,o- .� ,.6� h�. �•�. f:: y f r 9• SHEET: : x � f S q x,s.tYtz�:c";:`ai-� �� .r�},''�-�ntt Yrg a •�," � �- a >...: :k ,r."' x S, 4,I S;;;;:,= K%:1:4,��' `:I`' t '� �` ' ly,r�p?�,4 P :-s�sy,arm - .�'. ,.1.. ,f�4�: ;--fi>�s ;> rp. '>?.,�'!'"�ry ;t, ,z.1 t r.3 z,i^""`?�z{.�> .e;:` :34s��.,:;, EXISTING SPRINKLER HEAD � `� = - ..,.?> �ii'.Y4•",w',�.'.•,'`�4.!Y:,_:f -;[:r`7'y i§y�'fx S?��{^'�'3'�3.;;�_�'':��;>P:,...#",x ,,�E%� �`+•tits' - i,- ~'?:' :'„- aye ;r7^''9. 4,Y%' � .Ki^ L... �Y.{'.. i.,:. a:F•....� `,y:N.,��t`i r-- ,a a,:{.3 :t...'3;3. ;'t".iy.�=,x,f"a�>' t�. `y.- 'c%•3 N.'i�...,. i'�,,.y�'�::. ' m ;> � DEMO BASE FEED ��- v � --�.. � �_; �_ .._- _.�. �� ._.....:.Y ' ,�. ��� - _.: _ _ ..�..._- • I EXISTING SUPPLY/RETURN VENT TO REMAIN �,, . � , , . _ "'. hil 3 1 Zhil NEW BASE FEED, (1) CIRCUIT PER (4) WORKSTATIONS <0 EXISTING SMOKE DETECTOR =� ...._ A21 in EXISTING FIRE STROBE _1®1 0 EXISTING EXIT SIGN Z KEY t 0 - • KEY NOTE FOR REFERENCE ►:� NEW OR RELOCATED EXIT SIGN JOB NO ---) _: A2.1 NTS 208024330 ‘.,..., „,:,-, *oe) DOOR NUMBER SYMBOL EXISTING THERMOSTAT NORTH 1 t R TH PERMIT 06/26/13 208024330\ARCH\30-A2.1.0WG JAC 06/26/13 14:06 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO 7/8" WALL ANGLE AT 2 BFRC 2 g ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 CLIP $ MAX. °E < 0 SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT / LIMITING VV HEIGHT TABLE UJ c 0 q co STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER ATTACH STUD TRACK INTERIOR STRUCTURAL L 240 5psf .e 0 / C U °T� WALLS / 5p � ,► ,� ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS '' 3\ \ , /' THROUGH GRID TO ������ WALL ��� c) (9 co 0 WITHIN 8" OF PERIMETER � ��� \ / BRACE ABOVE DESIGNATION �, D co cm — LATERAL BRACING WITH APPROVED VERTICAL \ ° ° n 2 COMPRESSION STRUT AT 12'--O" OC EA WAY �� �\ ° ® ° SUSPENDED CLG / 362S125-18 24" 13'-5" g Z ° COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB /$ ° ASSEMBLY \ \ , 362S125-18 16 14 -4 < ‘1- Q ° a \ // ��45' 3625162-33 16" 16'--5" Q go [ "ATTACHED \ ° ° \I*iTCD :CING a�� ,� � yy �A A� CASING BEAD G 0A °� L/360 C� 5psf NOTE, FOR UNATTACHED WALLS PROVIDE A 1/2 0 `__.:_..�:_;__:.._; .. TO 3 4" GAP BETWEEN EDGE OF Ikiligill / ANGLE AND CLIP { -- DO NOT SCREW BERC 2 CLIP TO TRACK TO BE PROVIDED WHERE DISTANCE DESIGNATION PACING HEIGHT I I g SOUND ATTENUATION 1 BETWEEN PERPENDICULAR INTERSECTING r'_ _-- -___ - ---- " °� AT ALL NEW WALLS, TYP. 362S125-18 16" 12'-4" o co i__.,.,� I WALLS OR HORIZONTAL BRACING "6:3) � 4 CROSS RUNNERS FIT BETWEEN MAIN RUNNERS , TABLE MAX. LENGTH �- �_ " - sy � " _ � � 1/2" DIA CONDUIT (EMT) '-- 0" BETWEEN WALLS EXCEEDS 8 0 OC 362S125_..,33 16" 14-3 g o co p w MAIN RUNNERS AT 4'-0" OC / " ( 5 _-_-_ METAL STUDS ! !II °6 E_ a q Y'1 DIA CONDUIT (EMT} 7'-8" ..��' METAL STUDS SEE WALL HEIGHT g 0 tW V 6'--0" MAX SUPPORT WITH #12 WIRE AT 4'-0" OC OR ,� �(L WITH #10 WIRE AT 5'-0" OC EA WAY ) DIA CONDUIT (EMT) 9'-9" GYP BD EA SIDE - ' iJ TABLE FOR GAUGE AND SPACING 0 0 I ; E , • .me= w SGL 162S125-33 MTL STUD 12'-0 GONT ACOUSTIC SEALANT a LATERALLY BRACE MAIN RUNNER TO (1-5 8"x2OGA) j EA SIDE AGAINST TRACK 0 a an " WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH I NOTE: STRUCTURE AT 12 0 OC EA WAY. BACK TO BACK 1625125-33 15'-0 ; ; NO SEALANT AT SIM COND 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. Client ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6' 0" OF MTL STUDS (1-5/8"x2OGA) _ CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER SGL 250S125-33 MTL STUD 13'1-6" 1/2" MAX 1'' w t'� APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF (2-1/2"x2OGA) m • ' ,�� SECURE ALL HANGERS TO BLDG " BOTTOM TRACK TO FINISH � W CAPACITY. ALL LATERAL BRACING BACK TO BACK 250S125-33 15'-0 CONCRETE SLAB FLOOR W/ POWDER DRIVEN WIRES TO HAVE A 200# CAPACITY. STRUCTURE. TRAPEZE DUCT WORK „ T MTL STUDS (2-1/2 x2OGA) ANCHORS AT 4'-0" OC = _, cr AND OTHER LARGE OBSTRUCTIONS A.E1 SUSPENDED NONBEARING WA HEIGHT TAB ' �_ 1 o qv NOTE PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER c5 . "-- -' NTS Z A .1 AT FLOOR AND SUSPENDED CEILING 3 -1 -0 w A8.1 ¢ Fr THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. 1 U fa 2" CLR. 1 U.N.O. 1 1 l f Project ADJ MELAMINE PRECOA L w SHELF, TYP - EXISTING COLUMN SUITE 120 GYP BD PARTITION SEE PLAN w SOUND ATTENUATION BATT �A SOUND ATTENUATION BATT w I WALL BEYOND ._ AT ALL WALLS, TYP. w . �� __ AS OCCURS GYP 8D WALL AS OCCURS UPPER CABINETS, DEPTH TRIAN III , 4 LINE OF SILL AS OCCURS `` MAY VARY A5 RE D 13221 SW PARKWAY Q ,rql SEE CASEWORK ELEVATIONS 4 BACK AND , OR. 97223 • _ > 25" P.L. TOP 3'-6"± 2" SIDE SPLASH AS , --,_, ALUMINUM TRIM PIECE "CEE" w U.N.O. VERIFY ' OCCURS :: ikel :. W 1 " RETURNS, FINISH - m ` � � w " / cit.1 1'-5" MAX 4 BACKSPLASH, RETURN P-LAM COUNTERTOP AND < °C.&TO MATCH WINDOW FRAMES DOUBLE STUD AT JAMB, TYP �, AT END WALL CONDITIONS SPLASH 'z 30 1 ,A ,.: 4IW : (ANODIZED BUILDING - F` ` TO FAUCET P T � '. �LT9 �- CONTROLS • STANDARD) 1 .. r TIMELY FRAME, I �n TinAlp AELAMINE MATCH BLDG STD WRAP ALL EXPOSED PIPE ' g ORTLAND, OREGON..• � :a NEOPRENE SEAL ,,,� II 1{I is...;! :, J ) Y �� PER CODE › i , � I - • w4lb " I 't ‘..c. OF 0-° iti . \ J Z U 4 w -r ----- 1- 7 - 1 .:: %! t STOREFRONT GLAZING : / 111 IN I P-LAM O GROUP MACKENZIE 2013 Y .._.. SYSTEM (. _ * .I io € ALL RIGHTS RESERVED N OPEN BELOW PER CODE RUBBER BASE THESE DRAWINGS ARE THE PROPERTY OF 6" 1\,.. .,,,,___,---- ® GROUP MACKENZIE AND ARE NOT TO BE A 0) '/ M USED OR REPRODUCED IN ANY MANNER, \ A �� / �3 WITHOUT PRIOR WRITTEN PERMISSION 2'-0" VERIFY REVISIONS: cV o 17- (-11"' 1/ALL AT EXTEROR EXTERIOR LLI ! I ! °TI w,_ I w cnQ REVISIONS REVISION DELTA U U > THIS CLOSING DATE ww r SHEET HEAD SIMILAR 3"=.1%.-O" o TYPICAL 3/4"=1'-0" TYPICAL 3/4"=1'-0" CO �� A8.1 3"=l'--0" Q A8.1 o A8.1 < A8.1 n U FLUSH WOOD 13" NOTES: N--QTR- DOOR 5 A8.1 k t A. FINISH ENDS, TYP D. SHIM AS REQUIRED A. FINISH ENDS, TYP D. ALL CABINET FACES AND DOORS, PL-1 SIM , ,\ i (2) ADJ. B. CONFIRM REQUIREMENTS AND SIZES E. ALL CABINET FACES AND DOORS, PL-1 B. ALL COUNTER TOPS, EDGES AND E. ALL EXPOSED EDGES AT DOORS AND SHELVING . MELAMINE SHELF FOR ALL EQUIPMENT/APPLIANCES F. ALL EXPOSED EDGES AT DOORS AND BAKSPLASHES, PL-2 TO BE P-LAM TO MATCH ADJACENT I J` > __ __ PRIOR TO CONSTRUCTION OF SHELVING TO BE P-LAM TO MATCH C. SHIM AS REQUIRED VERTICAL SURFACES. ' o J CABINETRY ADJACENT VERTICAL SURFACES. — w C. ALL COUNTER TOPS, EDGES AND G. CONTRACTOR TO PROVIDE UNDER-COUNTER ICE Lw _ _ BACKSPLASHES, PL-2 MAKER. CONFIRM ELECTRICAL REQUIREMENTS. HOLLOW MTL KNOCK I P-LAM FACES MATCH EXISTING ICE MAKER AT SUITE 100. \ DOWN FRAME, TYP SHEET TITLE: D AILS AND \ 4"i:i :HD AON cr w AS o 25 P.L. TOP ._� S A5.1 A5.1 A5.1 a o w CEILING 4,CEILING w w tw P-LAM COUNTERTOP AND AL GN W/ LOWERS SPLASH / r / 1 5 - ___ 1 DRAWER AS OCCURS - - ' EXISTING COLUMN A8.1 / I IN ELEVATION , INSULATE EXPOSED k TT DRAWN BY HYH, ND I (1) ADJ MELAMINE � o SHELF, NO DRAWER OR PIPES PER ADA CODE cy „i ������ -- �� CHECKED BY LFI, PPA w t SHELF AT SINK LOCATION MO!0 \ . � I 1 - L �� �n CC o o FIN FLR SHEET:IN OPEN BELOW PER 1111 N d N I SEE DOOR I' ADA CODE P-LAM ∎— 11.1.. \ \ • SCHEDULE 2'-9" '-4"±1'_ ," (2) EQ 0 RUBBER BASE / FLUSH DOOR A : .1 , 2 , f " -\-- )1 d-\ 6 -4 5'-1"± > w 2'_0" /�3 / VERIFY • VERIFY BLY w to Y Y �_ oc JOB N0. m CABINETRY m A .1 1/2 -1 - a 2080243.30 8 COUNTER w,.._ CABINETRY io Q A .1 TYPICAL 3/4"=1'-0" m A .1 © COFFEE 107 1/4"=1 -0 w A81 © COFFEE 107 1/4"w�,_ � J PERMIT SET: 06/26/1 J 0 W w 208024330\ARCH\30-A8.1,DWG NO 06/26/13 11:51 1:1.00 • 05 CO g CD g �_ a CA oi co °o a. m V 46 CI 23 LCI Cg DOOR U INTERIOR F ° ' °® ` DOOR DOOR DOOR FRAME HDWR `� DOOR OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH DETAILS GROUP RATING COMMENTS PL-1: FORMICA, 7813—SP CARDBOARD SOLIDZ SCULPTED FINISH g 101A 3'-0'x8'-0" 4' FL SC S HMK FF 5/A8.1 H-1 -- -- 102A 3'-0"x8'-0" 13/4" FL SC S HMK FF 5/A8.1 H-2 -- -- PL-2: PIONITE, AT700 GROUNDWELL 103A 3'-0"x8'-0" EXISTING DOOR 1 o N. _103B 3'--0"x8'--0" EXISTING DOOR '°' 1 P-1: TO MATCH EXISTING 104A 3'--0"x8'--0" EXISTING DOOR 2 0 105A 3'-0"x8'-0" EXISTING DOOR a 2 RB—I: TO MATCH EXISTING �_ ! '5 ' d �' 2 106A 3'—0"x8'—0 EXISTING DOOR �- 1- g 0 > CO HARDWARE GROUPS: ABBREVIATIONS: o ! d :C a 2 H-1: PASSAGE EXIST EXISTING ▪ ° LATCHSET F75 GRADE 1, FF FACTORY FINISH _� BUTTS, SEAL, STOPS FL FLUSH € - a 0 H-2: LOCKING OFFICE HMK HOLLOW METAL KNOCKDOWN � LOCKSET F82 GRADE 1, 5 STAIN o ° pp0/ o ° MQ BUTTS, SEAL, STOPS SC SOLID CORE WOOD • 16. g ® 0 DOOR SCHEDULE NOTES: Client DOOR SCHEDULE COMMENTS: A. ALL DOORS/CLOSURES TO BE CHECKED, ADJUSTED, U) 1. EXISTING DOOR AT EXISTING —I RATED CORRIDOR AND/OR REPLACED TO BE IN COMPLIANCE WITH ADA �.° rtn ..� B. ALL TENANT ENTRY DOORS TO RECEIVE NEW DOOR Y =` W 2. PROVIDE NEW H-2 LOCKING HARDWARE WITH LOCKSET II, I HARDWARE AT EXISTING DOOR C. ALL SECONDARY DOORS TO HAVE DEADBOLTS REMOVED, k,k , ' IF CURRENTLY NOT INSTALLED. INSTALL COVERPLATES OR CHANGE DOORS AS AVAILABLE 6 VERIFY EXISTING CONDITIONS. D. ALL DOORS, FRAMES AND HARDWARE TO MATCH ft TENANT BUILDING STANDARDS. 13 Project PRECOA ROOM FINISH SCHE FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING ROOM ROOM NAME MAT'L MAT'L MAT'L MAT'L MAT'L MAT'L C HTNG FINISH N FINISH FINISH FINISH FINISH FINISH FINISH MAT'L COMMENTS TRIANGLE !II 101 CONFERENCE EXIST EXIST/RB EXIST GB/P GB/P GB/P EXIST EXIST 132218W 6.8TH PARKWAY 102 OFFICE EXIST EXIST/RB EXIST GB/P GB/P EXIST EXIST EXIST D, OR. 97223 103 OPEN OFFICE EXIST EXIST/RB GB/P GB/P EXIST EXIST EXIST EXIST I 1 104 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 105 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 106 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST c,.01) 4 1?(;$`). 3041 GB EXIST GB/P GBP `� 107 COFFEE EXIST RB /P EX_S / / EXIST _ EXIST P T.R ,. ALTO FINISH SCHEDULE NOTES: ABBREVIATIONS: I 1 _- A. ALL INTERIOR FINISHES BUILDING STANDARD, COLORS EXIST EXISTING 0 i A TO BE COORDINATED WITH TENANT. GB GYPSUM BOARD ORTEAND OREGON B. PATCH, REPAIR, AND PAINT ALL EXISTING WALLS WHERE P PAINT AFFECTED BY NEW WORK. PAINT NEW WALLS. RB RUBBER BASE � , 03 OF 0 C. EXISTING FLOOR FINISH AND BASE TO REMAIN THROUGHOUT, UNLESS NOTED OTHERWISE. PATCH, REPAIR, OR REPLACE AS REQUIRED WHERE AFFECTED BY NEW WORK. © GROUP MACKENZIE 2013 ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OF GROUP MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION 1 1 REVISIONS: z 0 Ins REVISIONS REVISION DELTA > THIS CLOSING DATE cc o SHEET . . ---•--1 9 -- 1 • I 1 i 1 . . 1 1 SHEET TITLE: SCHEDULES 1 1 DRAWN BY: HYH, ND CHECKED BY: LFI, PPA 1 1 SHEET: A it 1 1 JOB NO. 2080243.30 • J 1 1 PERMIT SET: 06/26/13 208024330\ARCH\30-A9.1-2.DWG ND 06/26/13 11:42 1:1.00