Loading...
Plans • 01 00 00 GENERAL DATA 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION 26 00 00 ELECTRICAL :DESIGN/BUILD GENERAL REQUIREMENTS STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT GENERAL 4... LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. #3082 T IT IPl � ETVIEI�TT for STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. 2. VERIFY ALL DIMENSIONS AND C ONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING a MARTIN W. HANSOM NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. // 1 THE PROJECT. . 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. t CLA KAM'S, OREGON,� MERIDIA.N CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OFA PROPOSAL SHALL BE CONSIDERED 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 6. FINISH QUALITY: V� THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 4. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE AREA PROCESS TRADE NOMENCLATURE WITH BATTERY BACKUP. 4 , O EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK OFFICE/OTHER AREAS TAPE/2 FINISH COATS*/ SMOOTH FINISH TAPED 5. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 VU DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO " * FLUSH POKE-THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH TECHNOLOGY GROUP, USG FIRST COAT" SAND AFTER TAPE/FINISH COAT(S) x ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE LOCATION TO SEPARATE POWER AND DATA WITH 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 6. TELECOMMUNICATION SYSTEM BY FUTURE TENANT. PROJECT #13280 W SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. SHOWN ON PLANS. INC. 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 09 53 00 SUSPENDED ACOUSTICAL CEILING 7. LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. R STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. 8. OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. Eimi INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 9. TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS EQUIPMENT PFtOJECT �� �I V 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND PROJECT CONSISTS OF REMODEL WORK TO 2,872 SF USABLE/3,196 RENTABLE SF OF 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO PROTECT EXISTING 3. BENT OR DAMAGED T-BARS TO BE REPLACED. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THAY OPERATE frel EXISTING OFFICE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO CARPETS. 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. DRYWALL/METAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL 8. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS ACCEPTABLE. 10.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. WORK TO MEET ADA REQUIREMENTS. AREAS AND COMMON AREA.'FLOORS TO BE SWEPT OR VACUUMED DAILY. 09 6519 RESILIENT FLOORING-VINYL COMPOSITION TILE 11.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA 9. PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 1. EXTEND FINISH FLOORING UNDER CASEWORK. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. r COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 2. INSTALL TILES IN QUARTER TURN PATTERN. 12.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE 4/ WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION ACTIVITIES. 09 91 23 PAINTING OF THE EXLSITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING PLUMBING WORK 10.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING INTERIOR: OFFICE LIGHTING RESTROOM FACILITIES. ON I FIRE PROTECTION SPRINKLERING 1. WALLS: 1. RE-LAMP EXISTING FLUORESCENT LIGHTS AS NEEDED. - 11.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. 2. OFFICE LIGHT FIXTURES- LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA I HEATING,VENTILATION&AIR CONDITIONING WORK PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER BALLASTS) 0 8 ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE COMMON BUILDING AREA BE USED FOR STORAGE. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 12.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. 3. RECESSED DOWN LIGHT: LITHONIA LF6N,26DTT LAMP,F6OSA RELFECTOR. 13.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 2. GENERAL NOTES: 28 30 00 ELECTRONIC DETECTION AND ALARM ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS DRIPS,OR ROLLER GENERAL BUILDING INFORMATION TENANT INFORMATION 14.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. SPRAY. FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR"SPECTRALERT ADVANCE DEVISES,OR APPROVED EQUAL. . .N OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: 15,CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. N 15350 SW SEQUOIA PKWY#300 MERIDIAN TECHNOLOGY GROUP, INC. 16.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. C. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND - • PORTLAND,ORE 97224 RAGS AT THE END OF EACH DAY. ® in OCCUPANCY AREAS&LOADS: 17.PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' d. UPON COMPLETION OF WORK CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING % cn P DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED AND SCRAPING USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. QI® P (503)624-6300 (PHONE) USABLE 2,872 SF 29 OCC PEN.DELIVER RECORD DRAW ,DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS W ^ 44 (503)624-7755(FAX) SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD e. PROTECT WORK OF OTHER TRADES. ril N N CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED v kD NUMBER OF EXITS REQUIRED AND APPROVED. f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. G M BLDG.#: BLDG. B(ttCO$2) B 1 EXITS 18.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 10 00 00 SPECIALTIES c/3 p p FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 10 44 16 FIRE EXTINGUISHERS p to M CONST.TYPE.: II-B TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF WHETHER OR NOT SHOWN ON THE DRAWINGS. 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) kfl O =X 19.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. �I4 A4 w THIS BUILDING HOUSES MULTIPLE TENANTS INCLUDING THIS TENANT. THE EXISTING 12 00 00 FURNISHINGS 20."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME BUILDING IS A FOUR STORY BUILDING OF87,890 SF AND IS FULLY SPRINKLERED. EACH PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. FLOOR IS LESS THAN 23,000 SF ALLOWING FOR NON SEPERATED USE. 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. • 21.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. 22.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 21 00 00 FIRE SUPPRESSION : DESIGN I BUILD 0 >1. TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO Fs REPLACEMENT AT CONTRACTOR COST. 1. ADJUST EXISTING SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE 4 a 23.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL HARD CEILING AREAS(GYPSUM BOARD/PIASTER}TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO PROJECT LOCATION INSTALLATION. ill SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE ■ J S.W. HAMPTON STREET COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 23 00 00 HVAC : DESIGN/BUILD N_A 24.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS HVAC-BID PROCEDURE - CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN U tri .r s - LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE "�'� )- . ---- INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE PROPER WORKING ORDER. al a �,� q ' CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TOARCHITECT A CONDITIONS REPORT OF EACH APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY UNIT �i V `, 1 BYE 9 THE ARCHITECT PRIOR TO INSTALLATION. 3. LIST TONNAGE OF EACH UNIT. L"� '": "�•'„'. 25.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUSTAND SCHEDULE ALL SERVICE - Q-- • INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. HVAC-DESIGN PROCEDURE 0 F. I 1"---:--5-- "i GENERAL USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS E� la LISTED BELOW. i, 1 1. REMOVE ALL EXISTING VET,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR �' TO INSTALLATION OF NEW FLOORING. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR 1.4C14 lizas • REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH Cam 4 a 0810 00 DOORS AND WINDOWS NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. b� INCLUDE THE FOLLOWING: I 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE �r",riiimai%//�/l%/j//rr1fl17rrra. �,. a. DUCTING AND SIZES 5 L3 It � ` al nhr+mr,uu, 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: ,.,,,� a. BAXTER AND FLAMING. (503)225-0486 b. SUPPLY AND RETURN LOCATIONS AND CFM L■� �� -� �' " b. D&D DOOR (503)205-5533 c. ROOF EQUIPMENT,SIZES AND LOCATIONS Il • �� .41 I d. UNITS REQUIRING DUCTED SMOKE DETECTION C. BENSON INDUSTRIES (503)907-2200 " U- I I I I I , r ( } e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH CIM Ons •1 I I I I I tl ) u.Lu d. GRANT S..r PLY (360)887-0647 H -a I I fl I 3. DOOR AND RELITE FRAMES SHALL BE TIMELY II,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 0 41 ' MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. g. ZONE DIAGRAM I 411111.1 = cl 1 I LI 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, HVAC DESIGN STANDARDS 1 FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS. frIrmal :• r" !!I I!I I 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 1. 350 SQUARE FOOT PER TON. I 0 n I I I 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. TENANT PRIOR TO CONSTRUCTION: 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR a. EXTERIOR EXPOSURE AREAS HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 1 LOCATION MAP b. INTERIOR AREAS,SIZE AND USE APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS C. CONFERENCE/TRAINING ROOMS A-1 NOT TO SCALE PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION SAMPLE. AND 24-HOUR USE. CE50) 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. [E4 CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. ZONES. 11.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT W1NDOUVS AND DOORS.TOUCH UP 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. Effillmil4 FINISH FOR AS NEW LOOK Tz T T O � ? � 5. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 712 Q 12.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. p -----„ I_______. _ _ _________________01_, 6. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE 0 04 09 00 00 FINISHES I I I i ',_,'I -�-® GENERAL CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. k '1 - --- '------ I '` ' ( I I ';i ! -�-fl 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. 7. ECONOMIZER TO MEET CODE AND AS FOLLOWS: E-+ 4--- --- I I I 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. r� b. BAROMETRIC RELIEF ON 5-7112 TON UNITS. V M a. FLOOR COVERINGS AND BASE k b. PLASTIC LAMINATES c. 8TONS AND ABOVE MUST HAVE POWER EXHAUST. p r I I I I I I I I ' d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. OS I I I ,b C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) a � '� I d. PAINT 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS.I IIIIIIIIIiI I ,� IIiIIItIiII I 16.DI5TRIBUTlON DUCTWORK: ` I `� e. TILE,MARBLE,GRANITE,STONE,AND GROUT AIN i�r'r'\ ," - I1 O a. SPIRAL ONLY IF EXPOSED. kp , f. TOILET PARTITIONS r= i® b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. t _ r,T, I - g. HARDWARE C. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH J) 11 I I ! I 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK I ■� I �, MINIMUM R4.2 INSULATION WITH FSK BARRIER. - I I I - 09 21 00 GYPSUM BOARD " V I I I d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1 WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD 0 N HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE j I I I GENERAL CLAMP. V) I� 04 I I Illk 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH I A - v ,� e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 I. ' I - - 1 TYPE S-12 SCREWS 12 O.C.UNLESS OTHERWISE NOTED. } I -- I--------------- REVISION __A_ ,__ DEGREES. .� rJ �� 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN '11""L,. -y' �``______A - - - - - -- ® FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT,. PAINT AS INDICATED. f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. AREA OF WORK °°- -`- ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. 3 COAT.PAINT ASr INDICATED. TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH 18 FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. CITY OF TIGARD 1 I © BUILDING G PLAN „ 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER 19.DIFFUSERS: Approved..r..�, 1¢„-.,g"�b4-"-m=a-- [1. 1*--- 2. z AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN A-1 SCALE 1"=40' �� WITH 1"TYPE S DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN Conditionally Approved.-........- [ 1 AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. See Letter to:FoI Iow---_-" , [ I 3" SPACING),EACH SIDE AND OPPOSITE SIDES. b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN ' 5. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2 x 1/2 ECG CRATE DESIGN TITUS 50F. , 4. Permit Number: 1 'do/ o METAL STUDS. c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST f WYE BRANCH. Address: - 1-51-0 0 S. 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. ►. , 7. AT ALL EXISTING IN'ALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLE,AND THEIR HOUSINGS AT PROJECT DY:...C.‘ - & __1)nl`e: pill. 6 PATCH HOLES READY FOR PAINT. COMPLETION. 8. UPON REMOVAL OF WALL BASE REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS J O BE REPLACED. NEW THERMOSTATS TO BE 7� HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. 4% WALL CONSTRUCTION MATERIALS APPROVED SUBSTITUTE: TOTAL-LINE SIGN TURE COMMER IAL THERMOSTAt MODEL NO P3T4-2800 -7 DAY C PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY MOUNT AT ADA HEIGHT(MAY Occupancy Type • 1. PROVIDE ,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE REQUIRE CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM INSTALLATION. Occupancy Load - THERMOSTATS AND BALANCE SYSTEM. - 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL Construction Type 2-:, PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. Rated Corridor DRAWN BY: DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 22.HVAC TESTING. Ron Tesch Energy Code 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, Accessibility :te PSI)G60. APPROVED PLANS AND SPECIFICATIONS. S ARE IBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH DATE:►T+�: /A/13 4 AN PROVIDE LISTED BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN r. - 1PJEt11 1D*�T�t TT 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. Approved OVO plans i� Vll - - C-36. c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND shall O on job site 6. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. FILED WITH PACTRUST. 7. USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: SYSTEM. a. AutoCAD FILE SHOWING AS BUILT INFORMATION. COPY WALL CONSTRUCTION EXECUTION b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. 4 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING c. HARD COPY OF AutoCAD FILE ABOVE. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. MATERIALS LIGHTER THAN 18 GA. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. BUILDING DEPARTMENT USE 1 0 0 E4:) 0 6 0 4 0 @I:: N3Q82 MARTIN W. HANSON r +� I P;.: 1 ! r 'j I . o �� o tCLA KAM S, OREGON Acp M I P Ui i T_1� , �/ 1 (----- :Ell,/11111/A _I/■-,--., ,-.., LI i I . �- o o , _ - _ _ o o � ' L PROJECT #13280 � RELOCatE lil _II �. 'i 1 or : ;Y"� CASEWORK FROM 105. �__I X CONVERT EXIST. INSTALL NEW TOP INSTALL NEW TOP AND• J-ROX t0 OUTLET ii SACK SPLASH AT a fi r I EXISTING COUNTER , .. I 48 RECESSED a TV OUTLET i 11 \ F'�' SHARED OFFICE ►:._.�_.�._, r? I �. ,, - -- - 0 CONVERT EXIST. 1 O+® 1— '� $ e� - —o_J-SOX TO OUTLET (112 I T Cab 1� .. ` J titc.1 0► ' �► FA BREAK i,v, IT/SECURE STORAGE i y _ Tr OFFICE s /6; F '`CONFERENCE ti 1106) r- �p 1 105 1 1� �' _K" ', = ; �{k; ii ~'' ''' � i---, ."¢j f� _aDD z-TONS `� i ���c 11131 y ® ( e DED AC 1 -~' N I %-_ __ I� ak, � �: X43 ril-60 1h'RINTER „ I d J D® NEW 5' it U+ Li �' I - -i �`�`' " —�I%, �' � i ,PIP"Pil in i„.1[ D A RECITE �'1 u't tit-D '11„ i __ } T1Id__Li � R�•� } t -- - N N N - — CIRC. LOBBYM/AIT -!i_ e " = 8 .J 11 _ 104 101 ., -�-` - k- _ ' I 1 i Tel R !11 {I �, -�-- -� } ti_ 1 - I 1 I _: •••• ' 1 ���O f; i f -I `I I- "" -_-_--�,..o i �i a I 1- i I I I �_1 I 1 Iii•_ �►• R il \ \4 11 ' -_! - f R .1 Wes. OFFICE - L' N.` it ■I I -I:....�:.�. 'I RECEPTION__ �, 11f »�-= -- _' _I ' 1:14 I ri 1111 I i�7 , 1\ l -, = ® _ • OFFICE OFFICE _`= =`_ �4 1100 !--' ��'a'` ©I �'' rf 1; • , to 11101 11091 7i (2)NEW 4' l; '� ; . la �' s, , , n �-y ' _ ® M DEMO 96' `- DEMO 96' '- DEMO 96' __ _ I 1 �" era z' DATA/OUTLET i-- DATA/OUTLET -' 4 v I i "_ _ _ ;.:r/ W .4 DATA/OUTLET I IT OFFICE \ OFFICE f;, ---_ VI N N 107 cJ F- i, 1� � ,r! s__- _ - �` %{ r il� \ I g _.,-, ---2,_ Q- 1108 1 `i I�.. -- t'1 1 , '�- i I I - j \�, -- I g ` �,I t0`\D ___.e, :._,._77. : _, '.. `4 - f' ;Iii NEW�' `� 1,---- �''`I l— \,\' .<�_ / i �' '\I _j /••\�°y ! li 1 i RECITE �_ , / I��1'' � � 1_ I. ®� v-1 T 1p 1 j J"IIVI' in in �' !T C .�., il f r i, it :`�3` ��I I f I liter��Cr 1 1 '�:. 1 1 I■ -TI f .. -a a — — - a a� �1 CONVERT EXIST. 'A$ 1 1021 COPIER ' II J-BOX 10 OUTLET :_�! %" ',�' I-= n FAX a f RELOC4TED 5' _ - RECITE B i\ f r Li lir— Ifl I)1.141 I \ ./`1 1-° B `\% I T' ' / ? _____ Fia 1 1 ill 1 , 4 ix r u ❑ i � H -11 I--1.7 IL-- A 1 L 1 Ir I I 0. N L L n 00 Anil PARTITION AND POWER PLAN Z REFLECTED CEILING PLAN EBZ Psi O 0 A-2 SCALE 1/8"= 1'-0" A-2 SCALE 1/8"= 1'-0" 0 Ilim * FINISH MATERIALS cci in ABBREVIATIONS 0 3 (FOR BUDGET ONLY.VERIFY SELECTION WITH PACTRUST PRIOR TO ORDERING.) BRK BRICK PAVERS Cal, 4 il ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. CP-# CUT PILE CARPET A IN DOOR SCHEDULE CARPET LOOP PILE: ER EX SIR Rc IL I DOOR DATA FRAME DATA HARDWARE LP PATCRAFT 10147-FAMOUS LAST WORDS II,47402 THIS WONT HURT,DIRECT GLUE ETR EXTEND TO ROOF >Eli PI 4 Fire Rating Remarks Mark VINYL COMPOSITION TILE (EXISTING) FWC FABRIC WALL COVERING Mark poor Size Thk Core Veneer Finish Nand Type Frame Depth Hardware Manufacturer Finish Function VCT ARMSTRONG EXCELON 51876 MINT CREAM 12"x 12"x 1/8" GT GROUT (141 asai 102 3'-0' x 9'-0' 1 3/4° SC SAPELE CHERRY Right • TIMELY II 4 1/S' LEVER/LOCK SGHLAGE 605 BRIGHT BRASS ND53PD RELOCATED DOOR/ADD FULL LITE KIT AND LOCKSET 102 HM HOLLOW METAL 4 103 3'-O' x 9'-0' 1 3/4' 5C SAPELE CHERRY Left • TIMELY II 4 1/8' LEVER LATCH SCNLAGE 601;BRIGHT BRASS ALI05 RELOCATE DOOR AND SIDELITE 103 BASE RF BERKE/MERCER 4"RUBBER FLAT 104 FUDGE Al ALL CARPET AREAS. PGA �i PAINTED GYPSUM WALL BOARD 105 3'-0' x 9'-0, 13/4' SC SAPELE CHERRY Right • TIMELY II 4 1/S' LEVER/LOCK SCLAGE 605 BRIGHT BRASS ND94PD RELOCATED DOOR IN EXISTING OPENING/NEW LOCKSET 105. RC BERKE/MERCER 4"RUBBER COVED 104 FUDGE AT ALL HARD SURFACES. PL-# PLASTIC LAMINATE 0 101 31-0'x 91-0' 1 3/4 SC SAPELE CHERRY Right • TIMELY II 4 1/8 LEVER LATCH SOILAGE 605 BRIGHT BRASS AL105 RELOCATED DOOR AND 51Df=CITE 107 PLW PLASTIC LAMINATE WAINSCOT ilmi'l . 108 3'-0' x 9'-0' 1 3/4' 5C SAPELE CHERRY Left • TIMELY II 4 1/S' LEVER LATCH SCWLAGE 605 BRIGHT BRASS ALI05 RELOCATED DOOR AND SIDELITE 108 PAINT: POT PORCELAIN TILE PT-1 MILLER 44$0 PREMIUM SATIN 8730W LOGGIA (BASE COLOR) PQTVV PORCELAIN TILE WAINSCOT 111 3'-0' x 9'-0' 1 3/4' 5C SAPELE CHERRY Right • TIMELY II 4 1/8' LEVER LATCH SCWLAGE 605 BRIGHT BRASS ALI05 NEW DOOR WITH 12' SIDELITE HI PT-2 MILLER 4480 PREMIUM SATIN 8733M WALNUT WASH(ACCENT COLOR) PT-# PAINT 112 3'-0' x 9'-0' 1 3/4' SC SAPELE CHERRY Left • TIMELY II 4 1/S' LEVER LATCH SCNLAGE 605 BRIGHT BRASS AL! S RELOCATED DOOR 112 113 3'-0'x 9'-0' 1 3/4' 5C SAPELE CHERRY Left • TIMELY II 4 1/S' LEVER LATCH SCHLAGE 605 BRIGHT BRASS ALI05 NEW DOOR WITH FULL LITE KIT 113 PLASTIC LAMINATE RC RUBBER BASE COVED 0 ' PL-1 WILSONART 4674-60 EVENING TIGRIS COUNTER,B.S.AND SELF-EDGE. RF RUBBER BASE FLAT DOORS,HARDWARE AND FRAMES SAT SUSPENDED ACOUSTICAL TILE SC SEALED CONCRETE FINISH SCHEDULE LE HARDWARE 605 POLISHED BRASS SV SHEET VINYL WALLS FRAMES PAC RED VCT VINYL COMPOSITION TILE RI'1* NAME FLOOR BA5E CEILING CLG. REMARKS RM* WBC WALL BOARD CEILING NORTH EAST SOUTH WEST HT. CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. WCG WALL CORNER GUARD 0 100 RECEPTION LP 4' RF E-PGWB PGWB PG11113 PGWB E-SAT 9'-0' -- 100 WD WOOD 101 LOBBY/WAIL LP 4' RF PGWB E-PGWB E-5AT 9'-0' -- 101 WOC WALK OFF CARPET 44 102 5HARED OFFICE LP 4' RF PGWB E-WW-PGWB PGWB PGWB E-5AT 9'-0' -- 102 WW WINDOW WALL 103 OFFICE LP 4' RF E-PGWB PGWB E-PGWB E-PGWB E-SAT 9'-0' -- 103 Ellggi 104 CIRC. LP 4' RF PGWB PGWB PGWB E-SAT 91-0' -- 104 105 IT/SECURE STORAGE E-VCT E-4'RC E-PGWB E-PGWB E-PGWB E-PGWB E-SAT 9'-0' -- 105 106 BREAK E-VCT E-4'RC E-PGWB E-PGWB E-PGWB E-PGWB E-SAT 9'-0' -- 106 CD 101 OFFICE LP 4' RF PGWB E-WW-PGWB PGWB PGWB E-SAT 9'-0' -- 101 ;i r"' 108 OFFICE LP 4' RF PGWB E-WW-PGWB E-PGWB PGWB E-5AT 9'-0' -- 105 4 109 OFFICE LP 4' RF E-PGWB E-WW-PGWB E-PGWB E-PGWB E.-SAT 9'-0' -- 109 1 411 4l! 110 OFFICE LP 4' RF E-PGWB E-WW-PGWB E-PGWB E-PGWB E-SAT 9'-0' -- 110 III OFFICE 4' RF E-PGWB E-WW-PGWB E-PGWB PGWB E-SAT 9'-0' -- 111 0 M E LP 112 SNARED OFFICE LP 4' RF PGWB E-PGWB E-PGWB PGWB E-SAT 9'-0' -- 112 113 CONFERENCE LP 4' RF E-PGWB E-PGWB PGWB PGWB E-SAT 9'-0' -- 113 a 00 9® a'+ 1 CONSTRUCTION LEGEND V ® E V I 1 1 EXISTING TO REMAIN ill 4t N C EXISTING TO BE REMOVED •. EZEZZZZ27:2222) le NEW STANDARD WALL REVISION ® NEW STANDARD WALL WITH INS. 1. 2. DUPLEX RECEPTACLE ELECTRICAL PANEL 3 cC' FOURPLEX RECEPTACLE CD POWER J-BOX 4 DD DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 5. ov EXISTING ELECTRICAL TO REMAIN tip FIRE EXTINGUISHER IN RECESSED CAB. 6. FLOOR MONUMENT W/SERVICES SHOWN ® FIRE EXTINGUISHER-SURFACE MOUNTED , SPECIAL OUTLET Q THERMOSTAT 8. 44 TEL/DATA MUD RING WITH PULL STRING D 2 X 4 FLUOR.T-8 3 TUBE FIXTURE X SUPPLY DIFFUSER DRAWN BY: � PARABOLIC LENS(DZ INDICATES DAYLIGHT ZONE) Ron Tesch ARETURN DUCT °WWIIIJP" 2 X 4 FLUOR.FIXTURE DATE: 6/4/13 mom PARABOLIC LENS/STEADY BURN BALLIST ® EXHAUST FAN PERMIT/BID 2 x 4 FLUOR.T-8 2 TUBE FIXTURE FIXTURE TILE • SPRINKLER HEAD LITHONIA ES8P FIXTURE INSTALL EXPLOSION PROOF TUBES OVER LAMPS 0 EXIT SIGN(LED RED) . RECESSED COMPACT FLUORESCENT LIGHT(TYP.) ({1 Hs HORN/STROBE FIRE ALARM(WALL MOUNT) STANDARD SWITCH I @( HORN/STROBE FIRE ALARM(CEIUNG MOUNT) ® OCCUPANCY SWITCH 0 SMOKE DETECTOR 0 CEILING OCCUPANCY SENSOR I RACO DEAD , • ♦ N, 308 io �I � 2 p / MARTIN W. HANSON '� 20 GA 3 5/8 METAL STUD BRACING O TO ROOF STRUCTURE AT 101-0'OC a o rte WHERE REQUIRED p 1 / , CLA KAMAS, OREGON 21-0' u s LITE KIT WI-4ERE SPECIFIED 6 Yr" , ,_ EXISTIN SUSPENDED CEILING w I 0 OF � • - -'RACO STYLE RECESSED.. . .. /. ` REVEAL HEADER. ' a � � PROJECT #13280 CONCEPT WALLS°I-481RDT z i z - O / 0 C3 a_ ' \ ADDITIONAL SWITCH 3-5/&'MIL.STUDS 24' 0G. w "' GANG LOCATION Cid / / 5/8 GYP. �GY .B .BOTH SIDES ' z CENTER LINE OF STUD a 0 5" IBA o ; \ \AL d \s,,,,,,__ U Z ELECTRICAL u w > !- OUTLET U OR J-BOX w o z ,Ciliiii) it 4' RUBBER BASE-TYP. o z = p ,,, 101pr n ATTACH BOTTOM TRACK TO FLOOR WITH s — p li POWDER DRIVEN ANCHORS AT 12 O.C. UNDERCUT DOOR 4S 6 p II 0 FL REQUIRED T14 CLEAN a3 74 8 :I FINISH FLOOR FLOOR 1=1NI51-4 ij11.: 4 1/8' • 1 TYPICAL WALL SECTION 4 MOUNTING HEIGHTS a N A-3 1" = 1 " A-3 1/2" = " SCALE 1 -0 SCALE 1/2 1 0 0 ON 04 N Qg ooi 4 O'0 o F RACO HEAD V1 A N N e o " r1^VD icy 0 - / V) M en 20 GA 3 5/8'METAL STUD BRACING a � 0 o 0 TO ROOF STRUCTURE AT 10'-0' OC e o 8' o �'8" WHERE REQUIRED i Q zx R-II BAIT INSULATION 4' CENTERED OVER WALL 2'-0' v FULL HEIGHT LITE KIT 1,441114 / WHERE SPECIFIEp , .._..-.:..� -- . .= _, EXISTING SUSPENDED CEILING w , 1 • r RACO STYLE RECESSED / CIMI) >1° 11110,-,.. 1 REVEAL HEADER :41117 CONCEPT WALLS 1-481RDT z 1 / z to timi p 4 w i 3-1/2' BATT INSUL. d - I lial IIIIM o / . i d a- / 3-5/8'MTL.STUDS *24'0C. w "' p ra: el a 5/8'GYP.BRO.80TH SIDES z \ o a / CENTER LINE OF STUD a 0 \ ," 0 la \ ca. 0. (I) R� z \ of \ w �' :� 3-1/2' BAIT INSUL.IN SOUND ATTENUATION WALLS w \ z Pr•�� "- 4' RUBBER BASE-TYP. \ p co III o 3 •'� ATTACH BOTTOM TRACK TO FLOOR WITH o R POWDI`R DRIVEN AT 12'OC. o Q o I FINISH FLOOR 6 @ . Cr)\ d LI 4 1/8' LITE KIT I N L. 5 FULL HEIGHT 2 WALL SECTION W/ SOUND SU >al m q A-3 SCALE 1"= 1'-0" A-3 SCALE 1/2" = 1'-0" LI, 1 0 4 immel 0 , ® , ,_ ______c --4--- — O O ROOF DECK o : a o OR BEAM 1 d cp Q > 0 RACO STYLE M w m -1 '-- - RECESSED REVEAL t �, V 14 HEADER. CONCEPT SUSPENDED CLG ASSEMBLY SOAP PAPER TOWEL SAN.NAP. PAPER TOWEL/ RECESSED WALLS .I-48'1RDT DISPENSER DISPENSER DISPENSER DISPENSER/ TOWEL DISPENSER Elul 0 0 A± 45? g N All. Z W 4Ih4 20 GA 3 5/8' METAL STUD BRACING ` — — TO ROOF STRUCTURE AT 1O'-0' D D C 1 M OC WI (2) 8 SHEET METAL o 1 ° N : SCREWS AT EACH END. BRACING D a fi b- TO BE PROVIDED WHERE DISTANCE o '- = o m a '4 p,� N BETWEEN PERPENDICULAR INTERSECTING "' N tL E x f� WALLS OR HORIZONTAL BRACING 1 Y 1� 1 0 1=4 -44 (43 $ BETWEEN WALLS EXCEEDS 12'-O' 00 SEAT COVER TOIL.PAPER/ GRAB BAR MIRROR / DISPENSER SE AT COY.D 15PJ 0 SAN.NAP. 44 0 DISPOSAL W WALL BRACING DETAIL 6 ACC. - MOUNTING HEIGHTS N o 3 a � a A-3 SCALE 3" = l'-0" A-3 NOT TO SCALE REVISION 1. 2. 3. 4. TYPICAL STUD 5. 6. 7• ► TYPICAL TRACK 8. INSTALL STUDS WITH SAME DIMENSION (10' MIN.)FOR—� DRAWN BY: BRIDGING ALIGNMENT Ron Tesch I DATE: 6/4/13 PERMIT/BID POWDER DRIVEN ANCHORS AT 12' O.C. (1)#10-16 SCREW PER STUD FLANGE A. 3 4 WALL BASE DETAIL A-3 SCALE 3" = 1'-0"