Report F:pcc- 2D oz INSPECTION,TESTING,AND MAINTENANCE 72-101 INSPECTION AND TESTING FORM DATE: lr-/B-,q TIME: 930 SERVICE ORGANIZATION PROPERTY NAME(USER) Name: 1,i0WALIPS %1-0-CTiO4//G0 Name: 4P..)ILA-- T14.44z-v Address: 3247 it/A/ ZQ Mgr Address: 13 9L€ SW 7AG/Fs'/C 146 1" Representative: N4 77W is1 s/141/LO Y Owner Contact: Q0:1 W 1 NQ'STPLCF S License No.: 04..4LEA Telephone: SOS-e-Z -135 T 0 Telephone: ?^T4-4!1.6785 MONITORING ENTITY APPROVING AGENCY Contact: "w/L i#Pt ,6L-EiTPoN/C.S Contact: G,TTY OF • 1 4.P Telephone: /84.621;•161204 Telephone: S'S-7/6-za/s9 Monitoring Account Ref.No.: LaPsseo/ TYPE TRANSMISSION SERVICE ❑ McCulloh ❑ Weekly LI Multiplex ❑ Monthly igital ❑ Quarterly ❑ Reverse Priority ❑ Semiannually ❑ RF ISKAnnually ❑ Other(Specify) ❑ Other(Specify) Control Unit Manufacturer: '014.,E1I7- he-L./1444T Model No.: 6ZOt0 Circuit Styles: 414145.1 Number of Circuits: // Software Rev.: 44010/ Last Date System Had Any Service Performed: A/iiv fA ST$.L.. Last Date that Any Software or Configuration Was Revised: A/A ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style 41 al-AAA $ _ Manual Fire Alarm Boxes Ion Detectors Z Ci41.011 16 Photo Detectors 3 &LAS 3 8 Duct Detectors Heat Detectors / C44405 $ Waterflow Switches 3 C4-AOS 3 Supervisory Switches Other(Specify): Alarm verification feature is disabled , enabled (NFPA Inspection and Testing,1 of 4) FIGURE 10.6.2.3 Example of an Inspection and Testing Form. 2002 Edition 72-102 NATIONAL FIRE ALARM CODE ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION Quantity Circuit Style WASS a Bells %Z r7Ld� a Horns Chimes Z e 6 . Strobes Speakers Other(Specify): No.of alarm notification appliance circuits: 'Y Are circuits monitored for integrity? i`5r Yes ❑ No SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style Building Temp. Site Water Temp. Site Water Level Fire Pump Power Fire Pump Running Fire Pump Auto Position Fire Pump or Pump Controller Trouble Fire Pump Running Generator In Auto Position Generator or Controller Trouble Switch Transfer Generator Engine Running Other: SIGNALING LINE CIRCUITS Quantity and style of signaling line circuits connected to system(see NFPA 72,Table 6.6.1): Quantity Style(s) SYSTEM POWER SUPPLIES (a)Primary(Main): Nominal Voltage ,Z D&ZC'. Amps Z1iVlr Overcurrent Protection: Type Amps Location(of Primary Supply Panelboard): FL.— 1 e (MALE 'Ptye.. L. Disconnecting Means Location: GKT 18 (b)Secondary(Standby): 2. A Storage Battery:Amp-Hr.Rating 9 1P$ Calculated capacity to operate system,in hours: 74. 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: TYPE BATTERY • Dry Cell ❑ Nickel-Cadmium Sealed Lead-Acid ❑ Lead-Acid ❑ Other(Specify): (c) Emergency or standby system used as a backup to primary power supply,instead of using a secondary power supply: Emergency system described in NFPA 70,Article 700 Legally required standby described in NFPA 70,Article 701 Optional standby system described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. (NFPA Inspection and Testing,2 of 4) FIGURE 10.6.2.3 Continued 2002 Edition INSPECTION,TESTING,AND MAINTENANCE 72-103 PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE Yes No Who Time Monitoring Entity Ll rot//GLITS1 e;sp Building Occupants �, ❑ GismisselAti, _ tscs Building Management 'v. U Ii 4 V Y7 y 6;pp Other(Specify) ❑ ❑ AHJ Notified of Any Impairments ❑ ❑ SYSTEM TESTS AND INSPECTIONS TYPE Visual Functional Comments Control Unit }1. Interface Equipment Lamps/LEDS Fuses ❑ ❑ Primary Power Supply *L. i$[ Trouble Signals Ni— Disconnect Switches Ground-Fault Monitoring X. SECONDARY POWER TYPE Visual Functional Comments Battery Condition Load Voltage Discharge Test Charger Test Specific Gravity LI TRANSIENT SUPPRESSORS ❑ REMOTE ANNUNCIATORS NOTIFICATION APPLIANCES Audible VC Y4r Visible Speakers ❑ O Voice Clarity ❑ INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS Device Visual Functional Factory Measured Loc.&S/N Type Check Test Setting Setting Pass Fail Pd3WE' _ L J 'e ❑ }e.1 71V�. Tomi R► ` - xe ti ❑ _AC.Tt• 3 t_ tMt>r ❑ ELJI T+ECAL. s-to I[E_ ID "-renews_ -Fut.i.'ta i Vr.. J i/duL't M6.ninmit NI- 1 _ X. ❑ Comments: (NFPA Inspection and Testing,3 of 4) FIGURE 10.6.2.3 Continued 2002 Edition • • 1 72-104 NATIONAL FIRE ALARM CODE EMERGENCY COMMUNICATIONS EQUIPMENT Visual Functional Comments Phone Set ❑ ❑ Phone Jacks ❑ ❑ Off-Hook Indicator ❑ ❑ Amplifier(s) ❑ ❑ Tone Generator(s) ❑ ❑ Call-in Signal ❑ ❑ System Performance I4 Device Simulated Visual Operation Operation INTERFACE EQUIPMENT (Specify) 'AP-10034y DP ❑ (Specify) ❑ ❑ ❑ (Specify) ❑ ❑ ❑ SPECIAL HAZARD SYSTEMS (Specify) ❑ ❑ ❑ (Specify) ❑ ❑ 0 (Specify) ❑ ❑ ❑ Special Procedures: Comments: SUPERVISING STATION MONITORING Yes No Time Comments Alarm Signal ❑ Alarm Restoration ❑ Trouble Signal $. ❑ Supervisory Signal ❑ Supervisory Restoration Alc ❑ NOTIFICATIONS THAT TESTING IS COMPLETE Yes No Who Time Building Management e ❑ CLAVpMl1Ly Monitoring Agency ❑ pa ILIA Building Occupants ❑ 41ppbWii,i.-- Other(Specify) ❑ ❑ The following did not operate correctly: System restored to normal operation: Date: Z-Air iy Time: THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS. Name of Inspector: Date: Time: Signature: Name of Owner or Representative: /• 444161/1- y . Date: f.-.l6--//,/ Time: Signature: ! • • - (NFPA Inspection and Testing,4 of 4) FIGURE 10.6.2.3 Continued 2002 Edition