Plans (24) • ° Building Division Memorandum Fire Department Building Survey and Plans TIGARD TO: Commercial Building Permit Applicants FROM: Brian Blalock, Building Official Community Development - Building Division DATE: January 1, 2007 SUBJECT: Fire Department Building Survey and Plans • Under the provisions of the Uniform Fire Code with Tualatin Valley Fire and Rescue amendments, a provision of their amendment requires the applicant submit with the building permit application the attached Fire Department Building Survey and Plans. Instructions for completing the form can be found at the Tualatin Valley Fire and Rescue Web site at www.tvfr.com. At the top of the page, click on Departments and select New Construction under Fire Prevention. The Building Survey Form Instructions are listed under Building Survey. If you have.any questions relating to the preparation, or questions relating to a term, please call Mr. John Dalby at 503 - 356 -4700. • I:\ Building \Fomu \FireSurveyMemo.doc 01/03/07 APPENDIX 111 -F • Ordinance 99-01 • APPENDIX III -F FIRE DEPARTMENT BUILDING SURVEY AND PLANS SECTION 1 — SCOPE Fire Department Connection locations Under Ground Location and size of water mains used for fire When a building permit is required by Oregon Structural protection (Public and Private) Specialty Code, building survey and plans for use by the fire Above ground and below ground tanks (Flammables, department, shall be prepared by the permit appellant and Combustibles, Chemicals, LPG, Propane, Cryogenics, submitted to building department for routing to the fire etc.) Material within the tank and size shall be • department in accordance with the provisions of Appendix indicated. Chapter Ill -F, at the time of issuance of the permits. Fences with gates (access points) • Exceptions: 1. Remodels or tenant modifications where no Interior of the building changes or modifications are made to the items listed in Area Separation Walls Section 3 of this Appendix. Occupancy classifications and occupancy separation walls 2. Group R, Division 3 Occupancies. 3. Agricultural buildings as defined in ORS Section 455.315. Corridors and hallways 4. Structures housing Group B, F, M, R, S and U Rated corridors shall be indicated Occupancies that are less than 4000 square feet ground Unprotected openings in floors floor area or less than 20 feet from the lowest finished Unprotected stairways, escalators, etc. floor to the highest finished ceiling. Protected stair enclosures Protected shafts (Elevator, etc. ) Horizontal Exits and exit enclosures and extension from enclosed stairway systems SECTION 2 — BUILDING SURVEY Location of fire protection system controls See the attachment to this Appendix Chapter for the building Location of fire alarm system panels survey form. Location of electrical main disconnect Note: Upon request the survey form and a set of Location of domestic water shut off valve instructions can be obtained from the fire department. Location of main natural gas shut of valve Location of tanks above or below the floors their size and SECTION 3 — PLANS DOCUMENTATION contents. General Plan information Plans shall contain, but shall not be limited to, the following information: Name and address of the building Type of Construction per OSSC Building Exterior Edition Date of Code and date built Direction arrow (North) Property lines • Architectural firm or individual that prepared the plans Building foot print Address and phone #. Access Roads (Required access roads shall be indicated) Fire Hydrant locations • • Fire Marshal's Offices \ ® M t North Division South Division East Division f 14480 SW Jenkins Rd. 7401 SW Washo Court 624 7th Street Beaverton, OR 97005 Tualatin, OR 97062 Oregon City, OR 97045 Tualatin Valley (503) 356 -4799 (503) 612 -7000 (503) 657 -1365 !lie ft Rescue Fax (503) 644 -2241 Fax (503) 612 -7003 Fax (503) 657 -7913 Page 1 of 2 Building Survey Report FMZ : (to be filled out by TVF&R) Code Edition: Name of Facility: Ao%Ptc Cf C :i-po Rh-r¢ G N - t-. Name of Building: $ Address: Owner: e l>fac''- jf 11" is 1V e 16 p"' ME N1- Telephone No. ( 503) .f'( ' 3l 00 Architect: _N1! cz 14_ .gs tap C t i c.'- P Telephone No. ( 563) c244 - 0 5 57- Architect Address: _ ii.056 SUS( V €L14 W-t Sr. S, t L`6, lk�p } OP -F6onr cti-�Z.3 ;rmAn :- : ' '' I!TE1VI COMM ', . ':DESCRIPTIOlY '_ 1. ` Occupancy Type � I Use o ,vi< l c€ Capacity cJ 0 2. Construction Type V $ Year Built 2.0 p8 3. Area (Sq. Ft.) Total 5 , o 44 Largest Floor t...t I k Basement N., m . e 4. Stories No. I Height 20 . L7 0 .. High Rise ❑Y N 5 a. Exterior Wall Construction ''P•t it— \' e N C 12. 01.t Wool:. oop 5. b. Opening Protection N a N >E P t u t P-e ;p 6. Interior Wall Construction Iv 6 [Mr* P 17 W A, Ll.g tA ND.E - �NIS A t 7. Floor Construction C0r.1 C rz-e -r* SZ-nr8 ON 0.1>f 8. Roof Construction I LT LAP l es F OVER 111 W o 0A ovE.g. I. Jour 9. Attic Draft Stops No. Iv N 10a. Occ. Sep. Wall Construction No. N 0 N E b. Opening Protection N o N F I I a. Area Sep. Wall Construction No. NONE b. Opening Protection N o N E 12a. Smoke Barrier Wall Construction No. I V e N E I b. Opening Protection NON E 13a. Corridor Wall Construction NI 0 VI E b. Opening Protection I v D Nt e I4a. Corridor Ceiling Construction N 0 N c b. Opening Protection N 0 N IE 15a. Shafts No . N 8 NE Type b. Opening Protection IV 0Nie Building Survey Report FMZ : (to be filled out by TVF &R) Name of Facility: • Tkc 1 r-te- C sS a Aps o rj'Po (244"T C 1 - - - u►tt.pt� ITEM. COMM: ,.. DESCRIPTION 16a. Stair Enclosure No. N o w g b. Opening Protection t I o t4 C 17. Stairs No. N e NE 18. Ramps No. 1\1 p NV 19. Interior Finish Class Room A teN E. Corridor Exit Enclosure 20. Exits No. Total Width t 21. Exit Hardware Type 1.1(C PeN /t C£s Vs) tTtt {�At.t.s – >ofs -- e - t.4ATtC 22a. Exit Signs/Illumination o NE. lkNp E 1 ( 2- PM C r b. Emergency Lighting A v l Me UtN — ntis TV - l - - 23. Auto Sprinkler Coverage N 6 u 24. Standpipe Class/L,ocations N o w ° 25. Fire Alarm Type /Coverage N b N E 26. Heating, Ventilation & Air Conditioning Type Fuel 27. Electrical Installation E C" f (2 t C A L p.V 1 cE Witurrent, 28. Stage/Platform N oN 29. Hazardous Area N Co NE. 30. Other Comments: Alternate Materials & Methods TVF &R'Use :Only.. ;:Inspected By; ' • 'Date No Attachments :Date- .. Updated,