Loading...
Specifications cLIMATE CONTROL RECEI VEQ0,SW 72' Ave Finial.ON em4 -HEATING&AIR CONDITIONING MAR 2 0 2013 503A53A822 —FAL 503300.7224 Ron's Service VaCITY OFTI GARD 16364 SW 72nd Ave CITY OF ISIOP' Portland, OR 97224 Approved rtiE P 1c-A-1-- [vT Conditionally Approved [ ] lir Overview See Letter to:Follow [ ] Attached Permit Number:67, FG7Otr _ � � Address:1 G, �D By: ) Date: :� d Approved plans shall be on job site. UNIT TO BE REPLACED OFFICE COPY Y o ♦! • . ■ f f ,.e i, r t-.4-et, 4 fi c ' -- -a __er - ' ! ,iii v c Y,. _ & SYSTEM DESIGN- INSTAIIATION ---SERVICE--- MAINTENANC1 Fidel 91 1 • A� Performance Summary For Untitled1 Project: Rons Service 03/19/2013 ,Prepared By: 04:31 PM Part Number:48TCDAO4A2A6-0A0A0 ARI SEER' 13.00 Base Unit Dimensions Unit Length' _ 74.4 in Unit Width: 44.0 in Unit Height' 33.4 in Operating Weight Base Unit Weight' 483 lb Medium Static Option 10 lb Total Operating Weight. 493 lb Unit Unit Voltage-Phase-Hertz' 460-3-60 Air Discharge' Vertical Fan Drive Type: Belt Actual Airflow. 1200 CFM Site Altitude* 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy' 31.44 BTU/lb Evaporator Leaving Air DB. 59.7 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy' 24.84 BTU/lb Gross Cooling Capacity' 35.65 MBH Gross Sensible Capacity. 26.25 MBH Compressor Power Input' 2.48 kW Coil Bypass Factor. 0.186 Heating Performance Heating Airflow. 1200 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 115.5 F Gas Input Capacity' 72.0 MBH Gas Heating Capacity' 59.00 MBH Temperature Rise' 45.5 F Supply Fan External Static Pressure' 0.50 in wg Fan RPM. _ 826 Fan Power _ _ 0.42 BHP NOTE' Selected IFM RPM Range: 770-1175 Electrical Data(Before July 30,2012) Minimum Voltage' 414 Maximum Voltage. _ 506 Compressor RLA• 5.8 Compressor LRA. 38 Outdoor Fan Motor Qty' 1 Outdoor Fan FLA(ea)' 0.8 Indoor Fan Motor Type. MED Indoor Fan Motor FLA' _ 2.1 Combustion Fan Motor FLA(ea)' 0.24 Power Supply MCA: _ _ 10.2 Power Supply MOCP(Fuse or HACR). 15 Packaged Rooftop Builder 1.34 Page 1 of 3 • -r. Performance Summary For Untitled1 Project: Rons Service 03/19/2013 Prepared By: 04:31 PM Min.Unit Disconnect FLA. 10 Min. Unit Disconnect LRA• 46 Electrical Convenience Outlet: None Electrical Data(July 30,2012 and Beyond) Indoor Fan Motor FLA' 2.6 Power Supply MCA: 11 Power Supply MOCP: 15 Disconnect Size FLA' 11 Disconnect Size LRA• 49 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 83.3 85.4 90.6 125 Hz 76.0 73.2 80.9 250 Hz 65.6 58.8 80.2 500 Hz 62.3 58.6 76.0 1000 Hz 59.0 58.3 74.6 2000 Hz 53.4 52.3 71.3 4000 Hz 54.4 47.2 68.5 • 8000 Hz 48.6 38.7 63.9 A-Weighted 66.3 64.4 80.0 Advanced Acoustics ►. Advanced Accoustics Parameters ; s ` 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 8 4. Height of obstruction. 0.0 ft ; 5. Horizontal distance from obstruction to receiver: 0.0 ft l 6. Horizontal distance from unit to obstruction:....._ 0.0 ft • / Detailed Acoustics Information Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center(Lw),dB 90.6 80.9 80.2 76.0 74.6 71.3 68.5 63.9 91.7 Lw A-Weighted Sound Power Levels at Unit's Acoustic Center(LwA), dBA 64.4 64.8 71.6 72.8 74.6 72.5 69.5 62.8 79.9 LwA Sound Pressure Levels at Distance Specified above(Lp),dB 58.2 48.5 47.8 43.6 42.2 38.9 36.1 31.5 59.3 Lp A-Weighted Sound Pressure Levels at Distance Specified above(LpA), dBA 32.0.32.4 39.2 40,4 42.2 40.1 37.1.30.4 47.5 LpA 1 Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or Packaged Rooftop Builder 1.34 Page 2 of 3 Performance Summary For Untitled1 Project: Rons Service 03/19/2013 Prepared By: 04:31 PM • a person with sound prediction expertise should be consulted. Fan Curve 2.0 MI 11110: 11.1111 1300 RPM 11111WINIMIMM53 00 al 1.6 `900 RPM -KrjivmorxoBE 1.4 1.2 IRIMIIMMWALIELM c,1.0 co E 700 RPM =MUM AAMMII 0.8 � ► 2008, 0.6 0.4 t__RPM 0.2 =W-_`i-�7.Tl1�1.. 50 BH• ' MEI 1.00 BH• 0.0i_� 0.50 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 Airflow(CFM-thousands) RPM=826 BHP=0.42 Maximum RPM= 1 175 Maximum HP=2.40 Note: Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.34 Page 3 of 3 MICRO-HOLD for Carrier Part Number: SUBMITTAL M i c r�Met! 48I50TC A/B04-A/B07,AID08,A09,A/D12,D14,D16; 50TCQ A04-A07,1308-D14;48150HC A04-A07,D08-D14; 0406-0100 FORM NO. 4250-9P DATE: 2/12 50HCQ A04-A07,D08-D12;48150TF,TM,HJ 004-014;48/50HE 003-006; SUBMITTED TO cny°I Tigard 50TFQ 004-014; 5OHJQ 008-009 Units COMPANY:climate contra DRAWN BY JOB NAME:Uncare EQUIPMENT' NOTES: FEATURES; • Manufactured from 16 ga galvinized steel • Package includes: •(4)Hold-Down brackets •(48)#10 x 112"tek screws(12)per bracket • Some units may require additional Hold-Downs. O - Use of this bracket provides a secure connection of the rooftop unit to the curb,but does not result in a calcu- O O lated curb. 1111 • When attaching the brackets,confirm there will be no 0 interference with anything on the unit base rail. 4.129" .941" O O O D 6" 2.757"" THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION•3035 N.SHADEIAND AVENUE,SUITE 300• INDIANAPOLIS,IN. 46226 •1-800-662-4822•••MICROMETL WEST•905 SOUTHERN WAY•SPARKS.NV 89431•1-800-884-4662