Specifications Fire Protection Services, Inc. �11 JL 5573 SW Arctic Drive n Beaverton, OR 97005 D L J J U Phone: (503) 590-3732 E l_ r 1 Fax: (503) 628-6214 HUNZIKER BLDG # p520/3 0c143 7940 SW HUNZIKER TIGARD, OR 97223 FIRE ALARM DESCRIPTION DESCRIPTION An Alarm Control Panel will be Installed to provide for the monitoring of the sprinkler system. A DSC GSM communicator will be installed to monitor the Fire System The required manual pull station will be mounted at 48"to the center of the device. An outside 110vt bell will be installed by the electrician Primary power to the panel shall be 110 VAC utility power with a 12VDC 7aH battery back-up. All fire alarm circuits will be wired with 16 gauge Fire Alarm Cable with the exception of NAC circuits, which will be wired with (minimum) 14 gauge Fire Alarm Cable. Monitoring is through Alarm Central Station, A UL Listed Monitoring Company in Beaverton, OR. (503.641.6761) All installation will be done according to NFPA 70 & 72 standards. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Silent Knight SK-4 Fire Control/communicator System Sensor i3 Series Smoke Detectors Silent Knight Dual Action Manual Pull Stations Wheel lock 110vt Bell — Global Project Values: Project Name:IHunziker Bldg 1 Standby Hours: 24 Project ID: Alarm Mins: 5 Prepared By:ID Phipps 1 Derating Factor:[ 1.2 Silent Knight-4 Calculations Date:110/9/2013 1 Voltage Drop Warning Version 02.25.09 Threshold%: 10 l Max NAC Current: 2.5 Amps Panel ID: SK-4 Model: SK-4 Fire Alarm Control Panel 'Max Panel Current: 3.0 Amps Location: near riser Volts: 24 VDC 'Maximum panel current can be 6.0 Amps with optional trans former Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ °/,Drop Standby_ Alarm &Type 1000 Ft. One-Way Ohms EOL SK-4 EST Main Control 1 0.085 0.175 SK-XRM24 110VAC Optional Transfmr. NA NA SK-CAC4 Class Converter Module 0.000 0.000 SK-4XTM Polarity Reversal Module 0.000 0.000 SK-4XZM Zone Relay Module 0.000 0.000 SK-4XLM LED Interface Module f 0r;� �„e rr:��; SK-RZA4 Remote Annutlda(or ;;�,- IDC-1 Initiating Device Cite f + 7 it- IDC-2 Initiating Device Ckt 2 P}5.000 0.000 IDC-3 Initiatin• Device Ckt 30.000 0.000 IDC-4 Initiating Device Ckt 4 k5.000 0.000 NAC-1 Notification Appl Ckt 1 5,.;:000 0.000 #16 Solid 4.02 0.00 20.40 .:0 00% NAC-2 Notification Appl Ckt 2 ___ ti,.000 0.000 #14 Solid 2.52 0.00 20.40 a. look Non-Rst Pwr Non-Resettable Power F'#+s000 0.000 #12 Solid 1.59 0.00 20.40 rte!°b0% Reset Pwr _Resettable Power 0.000 0.000 #12 Solid 1.59 0.00 20.40 g" (10% Total Standby Current(Amps) 0.085 0.215 Total Alarm Current(Amps) . Standby Time In Hours 24 0.083 Alarm Time in Minutes/60 (5 Mins) Total Standby AH Required 2.043 0.018 Total Alarm AH Required Command Shortcuts Total Combined AH Required 2.06 ( 1 Multiply By The Derating Factor 1.20 Print Page J Minimum Battery AmpHours Required_ 2.47 l Configure Circuits ) Panel ID: 15495(3) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: 1 Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @° Ckt.# Circuit Name %Drop Standby, Alarm &Type 1000 Ft. One-Way Ohms EOL 1 5495(3)Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(3)Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(3)Circe 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 4 5495(3)circuit4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux 5495(3)Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps)Total Output Power Required Total Standby Current(Amps) 0.075 0.205 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 1.800 _ 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 Panel ID: 5495(4) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: Volts: 24 VDC Max Panel Current: 6 Amps . Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ ° Ckt.# Circuit Name /oDrop Standby Alarm _ &Tyner 1000 Ft. One-Way Ohms EOL 1 5495(4)Circuit 1 _ 1:0.000 0.000 #12 Solid _ 1.59 0.00 20.40 0.00% 2 5495(4)Circuit 2 _ 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00°f 3 5495(4)Circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00°/ if 4 5495(4)Circuit 4 E0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00° ' Aux 5495(4)Aux Power Out "0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00°a 5495 _5495 Power Expander 0.075 0.205 0.000 (Amps)Total Output Power Required l Total Standby Current(Amps) 0.075 0.205 Total Alarm Current(Amps) ) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 1.800 0.017 Total Alarm AH Required Total Combined AH Required 1.82 - Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required_ 2.18 Panel ID: 5495(5) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: Volts: 24 VDC Max Panel Current: 6 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 1 5495(5)Circuit 1 _ __ _ _ 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(5)Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(5)circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 4 5495(5)CircW 4 0.000 0.000 #12 Solid 1.59 _ 0.00 20.40 0.00% Aux 5495(5)Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps)Total Output Power Required Total Standby Current(Amps) 0.075 0.205 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 1.800 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 FIRE ALARM CONTROL PANEL SK-4 & SK-4E Fire Alarm Control Panel r. _ 1P,'t (1' 4-zone fire p rotection at a price that won't '1.. burn your budget. ■3 . .ry, A «: The SK 4 and SK-4 E (SK 4/E) are four zone conventional fire alarm control panels (FACPs)that bring the latest in microprocessor technology • to conventional fire controls. The SK-4 is a 120 VAC FACP and the SK-4E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small- to medium-sized commercial, industrial, and institutional buildings. For more information about the SK-4/E system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description • Support for synchronization of The four zone SK-4/E is a 24 VDC standard ANSI audible signals and ADA compliant strobes per NFPA 72 FACP that provides four Class B initiating device circuits and two Class • Selectable for System Sensor, _ ___ B notification appliance circuit (NAC). Wheelock, and Gentex protocols • Selective silence feature a l l o w s . - -7 The SK-4/E NAC protocol includes the manual silence of horns while strobes ability to silence audible devices while continue to flash on the same NAC ; strobes continue to flash, using only a . Program for combination tamper single pair of wires. The SK-4/E is also supervisory monitor and waterflow compatible with conventional input alarm on one zone MOM devices such as two-and four-wire • Silent or audible walk test operation smoke detectors, pull stations, mode „ waterflow devices, tamper switches and . Alarm verification selectable per zone A other normally-open contact devices. • Program each zone for supervisory or .. Activation of a compatible smoke fire with separate red and yellow detector or any normally-open fire LEDs alarm initiating device activates audible • Disable switches provided per zone SK-4 and visual signaling devices, illuminates . Program NACS for an indicating LED, sounds the piezo —Silence inhibit Initiating Device Circuits (IDCs) Operating Voltage: 22 VDC nominal; sounder at the FACP, activates the Auto silence power-limited FACP alarm relay, and operates an —Strobe synchronization Standby Current: 4 mA optional module used to notify a remote _Temporal or steady signal Alarm Current: 15 mA min station or initiate an auxiliary control —Silenceable or nonsilenceable Short-circuit Current: 40 mA max function. —Disable Loop Resistance: 1000 max The SK-4/E is compatible with System EOL Resistor: 4.7K 0, 1/2 watt P Y • Form C alarm,trouble, and Sensor 13 detectors providing supervisory relays NACs Signaling Current: 2.5A @ 24 VDC advanced features such as drift • 3A total usable current with standard transformer or 5A compensation, maintenance alert, and total (2.5A per NAC)with additional freeze warning.Automatic • 6A total usable current with optional ( P ) second transformer(PN SK-TRM24 optional transformer, power-limited - synchronization of audio/visual devices or SK-TRM24E) EOL Resistor: 4.7K 0, 1/2 watt is provided, using three selections for • Optional dress panel (PN SK-DP2/4) Form C Relays manufacturer protocol. Types: Trouble, alarm, and Features Electrical Specifications supervisory SK-4 Primary AC: 120 VAC @ 50/60 Contact Ratings: 2A @ 30 VAC, • Four Style B (Class B) initiating Hz, 2.3A resistive device circuits(IDCs) SK-4E Primary AC: 240 VAC @ 50 Hz, • Two Style Y(Class B) notification 1.15A appliance circuit (NAC) Wiring: 14 AWG (2.0 mm2)with 600 V SILENT • Optional module converts all IDCs insulation min KNIGHT and NACs to Class A(PN SK-CAC4) by Honeywell FIRE ALARM CONTROL PANEL SK-4 & SK-4E Fire Control Panel Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK-4/E.The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices,alarm notification devices,and an on-board annunciator.It shall be compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply,four Class B initiation circuits which shall accommodate heat detectors,smoke detectors, and manual pull stations.Smoke detection shall be achieved with either 2-or 4-wire detectors that are compatible with the system.The initiation inputs shall be programmable as 1)verification zones in which detectors are automatically reset one time before signaling an alarm condition;or 2) combination waterflow supervisory zones that allows the FACP to distinguish between an alarm switch(waterflow device)and a supervisory switch (tamper)installed on the same circuit.The FACP shall have two 2.5 amp or 5 amp(with an additional optional standard transformer)programmable notification outputs.It shall have dedicated relays for alarm,trouble,and supervisory.It shall have two power outputs,one resettable and one non- resettable,each rated at 500 mA. The FACP shall have an on-board annunciator to indicate alarm,supervisory,trouble,and maintenance conditions.The annunciator must include LEDs for AC,GENERAL TROUBLE,ALARM SILENCE,WALK TEST,EARTH FAULT,AND LOW BATTERY.The annunciator shall also contain LEDs to annunciate fire alarms,troubles,supervisory,and maintenance by zone.The FACP must be fully operational from the annunciator and include buttons for ACKNOWLEDGE,ALARM,SILENCE,RESET,and WALK TEST.The annunciator must also have separate DISABLE switches for each zone and notification circuit.« Electrical Specifications (cont) Installation SK-4XTM Auxiliary Output The SK-4/E can be surface mounted Transmitter Module. Provides a Resettable and non-resettable using two key slots at the top of the supervised output for local energy Oporating Voltago: 21 VDC nominal backbox and two additional 0.26" municipal box trancmittor and alarm Current: 500 mA max, power-limited; diameter holes at the bottom,or semi- and trouble reverse polarity. total current for nonresettable power, flush mounted using the optional Trim resettable power and two NACs must Ring P/N TR-1-R SK-4XLM not exceed 6.0A(requires additional LED Interface Module. transformer) Approvals SK-XRM24 NFPA 72; UL Listed; Battery 110 Volt Transformer 3-6A. Type: Sealed lead acid only CSFM 7165-0559: 145; Charging Circuit: 27.6 VDC @ 0.8A MEA 297-01-E-3 SK-XRM24E max normal flat charge 220 Volt Transformer 3-6A. Ordering Information Charging Capacity: 18 AH SK-4 SK-RZA4 Size: 7 AH max allowed in FACP. Remote Annunciator. Larger batteries can housed 120 VAC Four Zone Conventional in an RBB accessory cabinet FACP SK-4XZM Compatible Initiating and NAC SK-4E Zone Relay Module. Devices 240 VAC Four Zone Conventional RBB See SK document PN 52612. FACP Remote Battery Box Accessory Mechanical Specifications Accessories Cabinet. Use if back up batteries are Cabinet Backbox Dimensions: too large to fit into FACP cabinet. 14.5"W x 15" H x 3" D SK-DP2/4 Dimensions: 16"W x 10"H x 6"D (36.83 W x 38.10 H x 7.62 D cm) Dress Panel.Allows access to the panel controls but restricts access to Digital Communicator Accessories Cabinet Door: system wiring. 14.677"W x 15.342" H x 0.375" D 5104B (37.28 W x 38.97 H x 0.95 D cm) SK-CAC4 Six-zone fire control communicator Cabinet Color: Red Class A Convertor.Converts Style B 5129 Telephone Requirements: (Class B) IDCs to Style D (Class A)and Four channel slave fire communicator FCC Part 15 and Part 68 approved Style B (Class B) NACs to Style Z Type of Jack: RJ31X (two required) (Class A) ft4 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all FORM#350305 Rev. C 12/06 specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight Copyright©2006 Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Phone:(800)328-0103,Fax:(763)493-6475. INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA 2 ,.4 • Addressable Pull-Station ( , BAs k IntelliKnight's addressable pull stations b v combine fast response with pin-point _,- " '° location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight- easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated Addressable contacts. 4 PULL 4 ddressable Pull • Reflective label makes it easier Station to locate in low light \ The SD500-PS is a single action Operation t '}J addressable fire pull station, and The SD500-PS/PSDA single action _ the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable FI.f on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. i the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset ,r# LA R M explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same , i PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32°F to 120°F • UL Listed communicating with the loop. The (0°C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) Specifications • Surface mount back box Operating Voltage: 24VDC SILENT available Standby Current: .55mA gre KNIGHT • Terminals - accept up to 14 Alarm Current: .55mA gauge wire I.Ib1.MO is,EMI INTELLIKNIGHT ACCESSORY }. Addressable e Photoelectric Type A . Of .4 Smoke Detector Detect smoldering fires quickly and get help fast .L, with IntelliKnight® photoelectric smoke detectors. al IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog Addressable conditions,electronic signal. Under normal - -w conditions, the status LED blinks Photoelectric Type approximately every 15 seconds, 1 Smoke Detector indicating that the head is communicating with the loop. The The SD505-APS is particularly LED lights continuously during the suited to detecting dense smoke alarm period. typical of fires involving materials such as soft furnishings, plastic, Features foam or other similar materials • Low profile, 2 inches, including SD505-APS Smoke Detector which tend to smolder and produce base Spedfications large visible particles. • Simple and reliable addressing Operating Voltage: 17-41 VDC The detector features automatic without mechanical switches Current Consumption: compensation for contamination • Automatic compensation for Standby: .55 mA and a simple detector calibration sensor contamination Alarm: .55 mA test procedure that can be run from • Built-in fire test feature Ambient Temperature: 32°F to 100°F the panel or remotely (using the • Simple detector calibration (0°C to 50°C) WindowsTM based downloading testing through the control panel through a Mounting 4"Square,4"OCT, software). or remotely 9 Single gang mud Operation WindowsTM based computer ring The SD505-APS units made up of software. Relative Humidity: 85% an LED light source and a silicon • Vandal-resistance locking noncondensing photo diode receiving element. In a features Air Velocity: 0-300 FPM • Field cleanable normal standby condition, the Compatible Bases: SD505-6AB receiving element receives no light • UL listed. meets NFPA 72 Ch 7 (Sold Separately) (6"Base) requirements SD505-4AB from the pulsing light source. In the re q event or fire, smoke enters the • CSFM approved (4'Base) detector and light is reflected from • MEA approved the smoke particles to the receiving • FM Approved SILENT element. 10 KNIGHT E INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Spedfications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. N Diameter=5-15/18" Diameter=3-15/16" ;fry •, _ offi E •. '. , Height=2 inches, ' including base • \ C MO ofinieNTair Model SD505-6A1 Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350225, Rev. 12/01 FAX: 763-493-6475 World Wide Web: http:Pwww.silentknight.com Copyright©2001 Silent Knight INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA • Addressable Pull-Station ,.. Aid Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. R FACP \\ r 4F S f - , . - mil '\ `. ; P f 'inn 'et' N �� 4 ,\t ' ~\ { \ .r�.�+ smogsStC•aIACPSIC- \ ,� 90,464.e yltf,-mIA(.Py{C \ '1 N. \ � ., Wiring r :air I 0 II i Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box 7i1 • SD500-PSDA f t,a — 1I a Installing SD500-LK &� w Dimensions ""�'"'-O~° tSILENT h KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350342, Rev.09/03 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2003 Silent Knight . CSC A Tyco International Company HSPA Universal _ Wireless Commercial - Fire Alarm Communicator - $ , - 1.018041 3G3O7OCF ' Features That litimwo.„ Make a Difference: • Uses HSPA(3G)network for high-speed, reliable and low- cost communications to an IP receiver • Automatically switches to 2G (EDGFJGPRS)if 3G service is 3G technology from DSC! not available 9Y • Compatible with control panels The 3G3070CF connects the alarm path shall be annunciated at the that communicate using the control panel to the HSPA network supervising station and at the Contact ID format and reports alarm signals directly to a protected premises within not more • Full event reporting monitoring station receiver(Sur-Gard than 24 hours of the failure. System 1/11/111/1V).The 3G3070CF uses • 4 on-board inputs the HSPA network to ensure low- How it Works • 4 on--board outputs(open cost,high-speed and reliable alarm The 3G3070CF can be used as collector) communications and is compatible either a Sole Communicator or as a with control panels that communicate • SIM card(included) Backup Communicator.When being using the Contact ID format. • Activation and initialization via used as a Sole Communicator the automated telephone activation The 3G3070CF is compliant 3G3070CF will replace the phone system(VRU),web-user or with the latest requirements for line connection on the panel and mobile interface provided by Communications Methods as as soon as it detects that an alarm mobile per UL864 and NFPA72 2010 needs to be transmitted it will send C24 Edition.It can be used in Fire the alarm across the HSPA network • PTM(Panel Transmission Monitoring applications as a single immediately.When being used as a Monitor)switches from PSTN communications technology, backup the communicator assesses to cellular on unsuccessful in which case any failure of the the connection to the PSTN phone communication attempts communications path shall be line, and only in the event of a phone • Compatible with Sur-Gar annunciated at the supervising station line failure will it send all alarm traffic System 1/11/111/IV monitoring within 5 minutes of the failure,or it across the HSPA network to the station can be used as part of a multiple monitoring station. receivers • communications technologies(for In instances where the control panel Includes UL listed power example in conjunction with a DACT). does not support Contact ID,the Supply transformer and 7 Ah When used as a back-up provision 3G3070CF has inputs pre-set to rechargeable battery shall be made to monitor the integrity transmit fire alarm,fire supervisory or • UL 864 listed of each communication path and system trouble. • listed failure of any communications MPhil communications C,H 0 1,,t y,, it USC cIi trihutor, www.ci c, c,,m 1 1-H '. &r,-7[= DSD . A Tyco International Company Alarm signals are transmitted directly without the need of Specifications a clearinghouse to the IP linecard of the monitoring station Dimensions 11-1/2"x 10"x 3" receiver(Sur-Gard®System Inl/III/IV). (29.2 cm x 25.4 cm x 7.62 cm) Activating & initializing the unit Input Voltage 120 VAC Activating and initializing the 3G3070 can be done using Current Draw 300 mA the automated telephone activation system(VRU),mobile Operating Environment 0°to 48°C(32°to 120°F) interface or web-user interface provided by CONNECT 24. Weight 12.8 lbs(5.8 kg) No special tools are required. UL Listing The 3G3070CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations.When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window.When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT)and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers.Contact your monitoring station or visit www.connect24.com to find a master reseller. Ordering Information: 3G3070CF-USA Universal Wireless Commercial Fire Alarm Communicator(U.S. ModeVSIM Card Included) O For product in(orni.LOn wr w.d,;c.corn