Loading...
Specifications I '134 K11 . - SE©CTAULIC PUBLICATION 10.01 FOR HVED .... E._.._._.. ION_.. ._..OR.DETAILS .. Extended Coverage/Light Hazard (ECLH) Pendent and Recessed Pendent AUG 1 2013 V3411 STANDARD RESPONSE CITY OFTIGARD V3412 2 QUICK RESPONSE These Model V34 ECLH sprinklers are designed with a larger orifice size to provide added BUIG DIVISION coverage at normal light hazard operating pressures.The design incorporates state-of-the-art, heat responsive,frangible glass bulb design(standard or quick response)for prompt,precise �. operation. � `4 The die cast frame is more streamlined and attractive than traditional sand cast frames.It � , is cast with a hex-shaped wrench boss to allow easy tightening from many angles,reducing r assembly effort.This sprinkler is available in various temperature ratings(see chart on page 2) and finishes to meet many design requirements. PENDENT RECESSED PENDENT V3411 AND V3412 V3411 AND V3412 P5zai.3...-do/,o SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid.During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the water- way is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Extended spray coverage is up to 400 square feet(37.2 sq.m)per NFPA 13. • TECHNICAL SPECIFICATIONS: Models:V3411,V3412 ACCESSORIES Style:Extended Coverage/Light Hazard Installation Wrench: -Pendent,Recessed Pendent • Open End:V34 Nominal Orifice Size: •716mm • Recessed:V34 K-Factor: 11.21mp./16.2S.1.^ Sprinkler Finishes: Nominal Thread Size:34'NPT/20mm • Plain brass Max.Working Pressure:175 psi/1200kPa • Chrome Plated Factory Hydrostatic Test:100%A 500 psi/ • White Painted** 3450kPa • Custom Painted" Min.Operating Pressure:5 psi/34 kPa 1, Temperature Rating:See chart on page 2. For escutcheons,cabinets and other accessories J refer to separate sheet MATERIAL SPECIFICATIONS �� Pendent Deflector:Bronze per UNS C51000 NOTE:Weather resistant recessed escutcheons Bulb:Glass with glycerin solution. available upon request. Bulb Nominal Diameter: • Standard:5,0 mm A For IC-Factor when pressure is measured in • Quick Response:3,0 mm Bar,multiply S.I.units by 10.0. I Load Screw:Bronze per UNS C65100 • Teflon is a registered trademark of Dupont Co. Pip Cap:Bronze per IJNS C65100 *' (JL Listed for corrosion resistance in all Spring: Beryllium nickel configurations. Seal: eflon*tape Exaggerated for clarity Frame:Die cast brass 65-30 Lodgement Spring:Stainless steel per UNS S30200 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para_ Location Date Approved Date www.victaulic.com jctaulic VICTAULIC IS A REGISTERED TRADEMARK OE VICTAULIC COMPANY.0 2004 VICTAULIC COMPANY.ALL RIGHTS RESERVED. FIRE PPC}"Y(~.CTlON PROuUCTS AUTOMATIC SPRINKLER:, 40.30 V34. K11.2 Extended Coverage/Light Hazard (ECLH) Pendent and Recessed Pendent V3411 STANDARD RESPONSE V3412 QUICK RESPONSE APPROVALS/LISTINGS Orate, Normnal Approved'Temperature Ratings 1 Er Model Size K-Factor Response Deflector Type (Refer to notes below.) V34�� Ord 1 :5-A 1,3,4,5-A I6 2 2-F 2-E 2-8 5/J 112 Recessed Pendent 1,3,4,5-A 1,3,4,5-A 1,3,4,5-A V3411 Standard I6 162 Up to S4'Adjustment 2-D 2-D 7-0 V3411 ti 1 1 2 Standard Recessed Pendent 1.3,4,5-A 1,3,4,5-A 1,3,4,5-A 16 16.2 Up to 34"Adjustment V34I2 sb I12 Quick Pendent 1,3,4,5-A 1,3,4,5-A 1,3,4,5-A 16 16.2 2-D 2-D 2-D V3412 - Ve 112 Quick Recessed Pendent 1,3,4,5-A 1,3,4,5-A 1,3,4,5-C lb 61 Up toWAdjustment 2-E 2-E 2-E V3412 °h 11 2 Quick Recessed Pendenr 1,3,4,5-A 1,3,4,S-A 1.3.4.5-C lb 16.2 Up to 34'Adjustmenr t Listings and approval as of printing.Not all temperature rating combinations are Approved or Listed. Check Victaulic for specific combinations. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. @ Light hazard only. fpspNt „ TareX .' , 1-UL A-135°F(57C),I55°F(68°C),175'F(79°C),200°F(93°C) 2-FM R-135°F(57°C),155°F(68°C),175°F(79'C) 3-ULC C-135°F(57°q,17S'F(79°C) 4-NYC/MEA 1 D-135°F(S7°C).155°F(68°C) 5-CSFM§ E-135°F(57°C) t MEA#62-99-E 5 CSFM#7690-0531112 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2004 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUIiC 4;1.1,4;0 2 • FIRE.PROTECTION PRODUCTS AUTOMATIC SPRINKUPS 40.30 ................ ....... ....... ....... ... ... 1/1A Ki Extended Coverage/Light Hazard (ECLH) Pendent and Recessed Pendent V3411 STANDARD RESPONSE V3412 QUICK RESPONSE .... . ..........., RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature—•FPC Sprinkler Viclaulic Temperature Part Nominal Temperature Maximum Ambient ClassificatIon Identification Rating Temperature Allowed Glass Ruth Color 13S CJO Ordinary 57 38 Orange 155 100 Ordinary C Red 68 38 Intermediate E 179 5 150 Vet low 7 65 Intermediate F 200 150 Green 93 65 • ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Sue • Quantity Sprinkler Finish • Escutcheon Finish Wrench Model Number . . . www.victaulic.com \ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2004 VICTALILIC COMPANY.ALL RIGHTS RESERVED. ictaulla FIRE PPOTECTION PROOUCT5_.AUTOMATIC S€RIi+IKI.t i?'i 40.30 VV' 4. K11.2 Extended Coverage/Light Hazard (ECLH)Pendent and Recessed Pendent V3411 STANDARD RESPONSE V3412 QUICK RESPONSE WARNING A A WARNING - • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to tip install,remove, or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that sup- 0 plied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner Is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler _ systems. In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be Iiil followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. I www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK.OF VICTAULIC COMPANY.0 2004 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt a'IUluc Fin PROTECTION PRODUCTS - AUTOMATIC SPRINKLER'S 40.30 V34, K11.2 Extended Coverage/Light Hazard (ECLH)Pendent and Recessed Pendent V3411 STANDARD RESPONSE V3412 QUICK RESPONSE DIMENSIONS W Adjustment Recessed—V3411,V3412(drawings not to scale) 21/4-(60 mm)_..1 Max Hole 7(51 mm) 4 Min.Hole 21/2'1 ® 118 nsm) (16/mm) /QY�It ;t Qy/J�Li TyPcalC kngTile ��L/=, ®�,I 1�9mm) 44 mm f T+t „fi., rilligill t 1`I l�� C 1 a; m I m �_� Finished Surface m) I (4i mm) .� .7 35 mm 1...-- MAXIMUM RECESS 2's/,: Standard Pendent )75 mm) V3411, V3412 MAXIMUM EXTENSION 3/4"Adjustment Recessed—V3411,V3412 (drawings not to scale) 2'/i(60 mm) Max Hole 2'151 mm) I Min.Hole T is/1." tfr itl 1'I/i (24 mm) (16 mm) ;AM T1'DY�ti Typical C ing Tile iTAVA 1/'rivir' � !35 mm) f f ® f `I ,ii I'1: � Finished Surface `■� (29 y'n) MAXIMUM RECESS 2uA: MAXIMUM EXTENSION AVAILABLE WRENCHES Pendent V',4 V'.4 Recessed Pend=r• — ROOM SIZE SPRINKLER PERFORMANCE FLOW AND PRESSURE(MINIMUM) V3411,V3412 Flow Rate End Sprinkler Pressure Room Size GPML)LPM PSI/kPa 16316 .;:30 30 7: 7."49%4.9 115 115 50 50 183 1S 33 33 9 9 5.5 X 5.5 125 125 60 60 20 X 20 40 40 13 IX 1 6.1 3 6.1 150 150 90 90 www.victaulic.com OtauliC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2004 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV,E :1 1■ i/1 Ili: , \ , I / / Extended Coverage/Light Hazard (ECLH) Pendent and Recessed Pendent V3411 STANDARD RESPONSE V3412 QUICK RESPONSE DISTRIBUTION PATTERNS Models V3411, V3412 K11.2 ECLH PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS-TRAJECTORY 10' 3.0m MOW 141n ♦♦ 18m •.`. • 4 •` • • 17m • • • 1 • • O • bm • 0 2' 4' 6' R' 10 12' 14' 16' 18' 06m 1.7m 1.8m 24rn 30m 3.7m 4.3m 4.9m SSm 30GPM ...••■■••• 33GPM 40GPM 113.6LPM 124 91.14,1 151 4L111.1 Miniumum Installation Spacing 1' Feet/meter. V3411-Standard V3412-Quick NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FlreLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly Instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.30 2552 REV E UPDATED o712004 Jotaullie VICTAULIC IS A REGISTERED TRADEMARK.Or VICTAULIC COMPANY.02004 VICTAULIC COMPAN/.ALL RIGHTS RESERVED. .--- t)..it / I •;• L © ® ae LPCB SEE VU:T PU ATION 10.01 FOR DETAILS Conventional(Old Style)Sprinklers MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE pattern rn which h deflects conventional xi arely hasprinkler of the is upwards toward the Tceiling and the 1 other half which nwlydts app other half downwards and can be installed in either the upright or pendent position.It is available with either standard or quick response bulbs.The design incorporates a state-of- I- the-art,heat responsive,frangible glass bulb design(standard or quick response)for prompt, kill precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames.It V2715 AND V2726 is cast with a hex-shaped wrench boss to allow easy tightening from many angles,reducing assembly effort.This sprinkler is available in various temperature ratings(see chart on page 2) and finishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters. As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement,refer to NFPA 13 standards. Accessoriies Models:V2725,V2726 Installation Wrench: TECHNICAL SPECIFICATIONS Style:Conventional Open End:V27,V38-3 Nominal Orifice Size:'/ /13mm Sprinkler Finishes: K-Factor:5.6l np./B.l S.I^ Plaines: • i \ . - Nominal Thread Size:y{NPT/15mm • d Max.Working Pressure:175 psi/1200kPa • Wax c Chrome plated• Factory Hydrostatic Test: White painted RAL 9010 _ 100%®500psi/3450kPa Lad• Min.Operating Pressure:7psi/48kPa • Peroprietary Nickel Teflon't"coating Temperature Ratings:See chart on page 2 • For cabinets and other accessories refer to Material Specifications separate sheet. Deflector:Bronze per UNS 051000 ^ For K-Factor when pressure is measured in . Bulb:Glass with glycerin solution. Bar,multiply S.I.units by 10.0. Bulb Nominal Diameter: • Teflon is a registered trademark of Dupont Co. • Standard:5.0mm t Not VdS approved • Quick Response:3.0 mm • Also,UL Listed for corrosion resistance. #11 i Load Screw:Silicon Bronze per UNS C65100 ifi \ Pip Cap:Silicon Bronze per UNS C65100 �� r Seal:Teflon'tape Spring:Beryllium nickel Frame:Die cast brass 65-30 e'' Lodgement Spring: �� MP Stainless steel per UNS S30200 Exaggerated for clarity ENGINEER JOB/OWNER CONTRACTOR _Para Submitted By Spec Sect System No._ Approved -- Date Location Date -- -- ✓ctaulrc www.victIS A REcom VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.Cr 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN T HE USA. REV 13 EIRE PROTECTION PRODUCTS- AUTOMATI..SPRINKLERS 40.17 V27, K:5„6 Conventional(Old Style)Sprinklers MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE APPROVALS/LISTINGS Orifice Nominal Approved Temperature Model Size K-Factor Response Deflector Type Ratings 1 V2725 5 r' Standard Conventional' 13 8.1 5–13 86 Quick Conventional" 1,2,3,4,5–B V2726 13 I Listings and approval as of printing. For K-Factor when pressure is measured in Bar,multiply SI.units by 100 @ All are approved open,except for areas designated'No.' Not to be used with any recessed escutcheon APPROVED TEMPERATURE RATINGS 1–UL A–135'F/57°C,155'F/68'C,175°F/79'C,2001/9311C,286°F/141'C,360'F/182`r 2–ULC B–135'F/57 11C,1551/68°C,1751/79°C,2001/93°C,286°F/141°C 3–NYC/MEA i 4–CSFM 9 5–Vd5/CE t MEA 562-99-E § CSFM#7690-0531112 RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Temperalarr- r Viclaulic - - Sprinkler Temperature Part Nominal Temperature Maximum Ambient Cles,ification Identification Rating Temperature Allowed Glass Bulb Color Orden 57 308 Orange Ordinary 1685` 1 80 Red Intermediate E 179 150 Yellow Intermediate F 2000 65O Green High 1 286 2107 Blue ..... .. Extra High t K 1820 149 Wavy –t M Open — No Bulb #Standard response only All are approved open,except for areas designated No --150/65 if wax coated. "Also available in wax coated. VIGTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct8UI11C' r 2 f'$:= it FIRE.PROTECTION PRODUCTS_.AUTOMATIC SPRINKLERS S 40.1 7•. V277 K56 Conventional(Old Style)Sprinklers • MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number h. i• Style Temperature Raring F-Factor Thread Size Quantity Sprinkler Finish ... ........... ................ Wrench Model Number WARNING A WARNING • Always read and understand installation, care and maintenance instructions, supplied with each box of sprinklers, before proceeding . with installation of any sprinklers. c • Always wear safety glasses and foot protection. .::-nC • Depressurize and drain the piping system before attempting to install, remove or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must he ' strictly followed. • Painting, plating or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 4:11115 Failure to follow these instructions could result in serious personal injury and/or property damage. • The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes.care and maintenance of sprinkler AIsystems. In addition,the authority having jurisdiction may have additional iiiiiihav V-V maintenance,testing and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. . • www.victaulic.cam VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. iCtaUIrC F;Rf; '-r'�it}t'I-:C:1It °4 Pt'tCrOt3ti+`.i i'4,!Sti;li(7E't! L5C.713�titil.r.0,,:, 40.17 • 1 ' .: Conventional(Old Style)Sprinklers MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE DIMENSIONS Conventional PendentNpright-V2725,V2726 A bl mm/ 51 'ah47 1mm/ r 1=f 14 31 mm/ i rh,rn AVAILABLE WRENCHES Sprinkler Type V38 or 538.3 Recessed V27 Open End V2725,V27'5 C amen tron31 DISTRIBUTION PATTERNS Models V2725, V2726 K5.6 standard conventional-pendent position distribution patterns-trajectory 1Q 7 4rn \ •♦ I ern • • • 4' • 12m : • • • • • 1. n6n • • • • • 0 7' 4 6 8' 10 12' 14 16 Obm I.?in 1.8m 24m SOrn 37rn 43m 4.901 7p4 4.4.•••■•••' 15 psi 410•11■• 30 psi 48 kPa 103 kPa 207 kPa Refer to notes on page 5. VICTAULIC IS A REGISTERED TRADEMARK OF NCTAULIC COMPANY 0 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN 1HE USA. jctsaulle .,,, 1st:V ti FIRE.PROTECTION PRODUCTS _AUTOMATIC sPR#rttt#.EF#^, 40. 17 V2 7 I K5 Conventional(Old Style)Sprinklers • MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE DISTRIBUTION PATTERNS Models V2725,V2726 K5.6 standard conventional-upright position distribution patterns-trajectory la. ' `• 3.am� •• •* 000000 •`• •4♦♦ 2 4rn •N• ♦♦ •` 444'4 ♦♦ • L' ♦ 18rn • •` ••` • • 4' 12rn • • ♦ • •` • • 2• •• 0 xn • • • o ` • 2' 4' 6' II' I0' 12 14' 16' 0.6m I.2m 1.8m 2Am 3.0m 3.7,n 43m 4.9m 7psi ...••■■• • 15 psi 30ps1 48Ma 103 kPa 20711Pa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. iCta U I i C RFV { izc : . {.,;. ... : ) .. 40.17 }: : Conventional(Old Style)Sprinklers MODELS V2725 AND V2726 STANDARD AND QUICK RESPONSE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. VICTAULIC IS A REGISTERED TRADEMARV OF VICTAIJLIC COMPANY.0 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN(HE USA. CtauI11C'