Specifications 1:7952_6 Caq SIEMENS Siemens Infrastructure&Cities 15201 NW Greenbrier Pkwy,Suite A4 Beaverton,OR 97006 Phone: (503)207-1900 Fax: (503)207-1901 Siemens Infrastructure&Cities Fire Alarm System Contractor Shrader Martinez General Contractor FIRE ALARM SUBMITTAL Washington Square L'Occitane Suite H06 Siemens Job Number 440P-134677 Siemens Project Manager Charles Hughes Submittal Version Date Siemens Project Engineer Charles Hughes Issued For PernoVConeVucCon 07/02/17 Proprietary document for approval only Table of Contents SIEMENS I BILL OF MATERIAL & COMPONENT SPECIFICATIONS BILL OF MATERIALS SIEMENS Washington Square L'Occitane Suite H06 Fire Alarm System Item Part# Qty Mfg Mfg# Description 1 FP-11 2 Siemens 500-095112 Intellegent Photoelectric Smoke Detector 2 DB-11 2 Siemens 500-094151 Detector Base for FP-11 No Data Sheet Available PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 7/2/2013 SIEMENS Catalog Sheet Fire Safety& Security Products MXL, MXL-IQ and MXLV Panels Intelligent FirePrintTM Detector Model FP-11 ARCHITECT AND ENGINEER SPECIFICATIONS • Most Sophisticated"Detector Intelligence"available in the Fire!Life Safety market • Multi-criteria fire detection for the price of a photoelectric detector • FirePrintTM technology to distinguish between deceptive phenomena and an actual fire • Easily programmed to match specific hazard profiles • from the fire-alarm control panel (FACP) • Pre-Alarm reporting based upon fire profile selected • Remote-sensitivity-measurement capability ++ • System-logic activation based upon any of three(3) inputs from the detector(smoke, heat or neural network) • Field-cleanable chamber with replaceable chamber parts • Compatible with field programmer/tester(Model DPU) or FPI-32 Upgrade Kit • Supports software-based,automatic environmental compensation (EnviroLINK) • Multi-color,detector-status LED • Backward compatible with older MXL systems • (Rev. and above) • (2)Two-wire operation • Optional fully programmable relay base,audible base • ®UL and' ULC Listed; and duct housing FM,CSFM & NYMEA Approved Product Overview The Intelligent Fire Detector(Model FP-11)provides methods and reduces installation and service costs by the most highly evolved detection system- electronically programming and testing the detector including the most sophisticated level of protection; prior to installation. as well as nuisance-alarm immunity-currently available in the Fire!Life Safety market. Specifications Model FP-11 utilizes advanced detection Model FP-11 is a plug-in, two-wire, multi-sensor technology that allows the detector to distinguish detector with photoelectric and thermal inputs that is non-threatening deceptive phenomena (i.e.- compatible with the MXL family of FACPs. Each cigarette smoke)from actual fire hazards, while detector consists of a dust-resistant,field-cleanable optimizing detection for the area of its intended photo chamber; a solid-state, non-mechanical thermal zone. Model FP-11 uses state-of-the-art sensor,and microprocessor-based electronics with a microprocessor circuitry with error check,detector low-profile plastic cover and base. self-diagnostics and supervision programs. Model FP-11 utilizes state-of-the-art ASIC and surface- Model FP-11 is compatible with the Siemens mount technology for maximum reliability. Every Industry, Inc.- Fire Safety division's FPI-32 upgrade Model FP-11 fire detector is shipped with a protective kit or Siemens'field-programmer I tester(Model dust cover. Model FP-11 fire detector utilizes an DPU), which is a compact, portable and menu- infrared light-emitting diode(IRLED), and light sensing driven accessory for efficiently programming and photodiode. Under normal conditions, light transmitted testing detectors electronically. Model DPU or by the LED is directed away from the photodiode and FPI-32 upgrade kit eliminates the need for scattered through the smoke chamber in a controlled cumbersome, unreliable mechanical programming pattern. Intelligent FirePrintTM Detector 6175 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) The smoke chamber is designed to manage light sophisticated mathematical formulas or algorithms— dissipation and extraneous reflections from dust comparing this input to characteristics of both particles or other non-smoke airborne contaminants threatening fires and deceptive phenomena that would in such a way as to maintain stable, consistent deceive any ordinary detector. This technology was detector operation. When smoke enters the developed over years of research and reviewing the detector chamber, light emitted from the IRLED results of over 20 years of fire-test data in one of the is scattered by the smoke particles,and is received world's most advanced fire research centers. The by the photodiode. results of this research are the mathematical models Model FP 11 also utilizes a modern, accurate and that form the algorithms used in FirePrint. No other fire shock-resistant thermistor to sense temperature detector has this level of intelligence or this amount of changes. The'on-board'FirePrint technology research and development supporting its design. allows the detector to gather smoke and thermal The software of the microprocessor can identify and data, analyzing this data in the detector's'neural disregard false input caused by radio frequency(RFI) network.' By comparing data received with the and electromagnetic(EMI) interference, and validates common characteristics of fires, or fire fingerprints, all trouble conditions before annunciating or reporting Model FP-11 can compare these'fire prints'to to the control panel. The microprocessor for Model FP- those of deceptive phenomena that cause other 11 uses an integral EEPROM to store the detector's detectors to alarm. The advanced FirePrint address and other critical operating parameters,which technology allows the Model FP-11 to accurately include the assigned program values for alarm and determine a true fire hazard from non-threatening, trouble thresholds. deceptive phenomena—without the need to use Communications within the detector; between Model alarm delaying verification and confirmation FP-11 and the FACP;or with the field programmer! techniques,which can increase the probability tester(Model DPU), are supervised and safeguarded of losses due to fire. against disruption by reliable, microprocessor-based Model FP-11 provides the highest level of detector error checking routines. Additionally, the intelligence available today with a detector! microprocessor supervises all EEPROM memory control-panel link that allows the user to program locations and provides a high degree of EEPROM failure the detector for the specific hazard profile. fault tolerance. Detectors are optimized by selecting one(1) of In MXL 1(V)applications, Model FP-11 determines its the following applications: operating status to be in normal,alarm,or trouble • Office!Retail mode, depending on the difference between the alarm • Lobby threshold values stored in the detector's memory and • Computer room the detector's latest analog measurement. The detector • Dormitory then communicates changes in its status to the FACP. • Healthcare facility In addition,the MXL 1(V)FACP will sample the value of • Parking garage • Utility!transformer room the analog signal for Model FP-11 over a period of time, • Hostile environment in order to determine if those values indicate excessive • Precious storage buildup in the photo chamber. In the event of • Air duct excessive buildup, the MXL 1(V) FACP will accurately • Warehouse/light manufacturing indicate which detector shall require maintenance. Once programmed,the software does the rest— Model FP-11 is listed as a self-testing device. The LED no guessing on detector sensitivities or alarm for Model FP-11 flashes GREEN every four(4)seconds, verification —the FACP programs Model FP-1 1 for indicating communication with the FACP, and that it the protected area without any confirmation delays. has passed its self-test. Should the detector sense a Once optimized for the hazards in the protected fault or failure within its systems,the LED will flash area, Model FP-11 provides the utmost means in AMBER, and the detector will transmit that data to the detection. Should the operator or installer forget FACP. A quick visual inspection is sufficient to indicate to program the detector, Model FP-11 will revert the condition of the detector at any time. If more to a default setting that, in turn, allows operation detailed information is required,a printed report can be as a standard photoelectric or photothermal provided from the MXL panel, indicating the status and detector. settings assigned to each individual detector. The FP-1 l's FirePrint technology for Model FP-11 When Model FP-11 moves to the alarm mode, it will monitors input from the photo chamber and the flash AMBER,and will transmit that data to the FACP. thermal sensor,evaluating this information with When the MXL 1(V)confirms the condition of the • detector, the FACP will instruct Model FP-11 to flash SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) RED—and to continue flashing RED, until the detector locks,as well as an installation tool, preventing system is reset manually at the FACP. At that same unauthorized removal of the detector head. Model time, any user-defined system alarm functions DB-11 has integral, decorative plugs to cover the outer programmed into the system are activated. Each mounting screw holes. Model FP-11 detector can operate one(1) remote Model FP-11 is electrically compatible with existing alarm indicator;one(1)auxiliary relay, or one(1) MXL-detector accessories, including relays, remote audible base. lamps,duct housings and audible bases. With duct Detector sensitivity, calibration and identification housings, a base adapter and new detector housing are dynamically supervised by the FACP. Detector cover are required (order AD-11 UK upgrade kit). To use sensitivity and pre-alarm levels are a function of the existing Model DB-3S base or audible base, Model FP-11 application chosen at the FACP,and are controlled requires a base adapter(Model DB-ADPT). by the panel. If an alternate, non-FirePrint mode is All Model FP-11 detectors are approved for operation selected, then the sensitivity can be changed from within the®UL-specified temperature range of 32°F the FACP. (0°C)to 100°F (38°C). The Program 1 Test unit(Model DPU)or FPI-32 upgrade kit is used to program and verify the Application Data detector's address.The technician selects the Installation of the Model FP-11 series of fire detectors accessory's program mode to enter the desired requires a (2)two-wire circuit of 18 AWG (minimum) address. In turn, Model DPU or FPI-32 automatically thermoplastic fixture wire enclosed in conduit, or 18 sets 1 verifies the address, and tests the detector. AWG (American Wire Gauge) limited energy, shielded Model DPU also allows the user to change the cable without conduit, if permitted by local codes. Field device ID from that of a Model FP-11 detector to an wiring should conform to local and national electric older detector ID (such as: ILP-1, ILPT-1, ILP-2, ID- codes and the control panel wiring specifications. 60P or ID-60PT)to allow for easy replacement of older detectors without the need of reprogramming "T-tapping"is permitted only for Style 4(Class B)wiring. the FACP. • Model FP-11 fire detectors can be applied within the The FPI-32 upgrade kit operates on AC power or maximum 30-foot center spacing (900 sq. ft.areas), as rechargeable batteries, providing flexibility and referenced in NFPA 72. This applications guideline is convenience in programming and testing based upon ideal conditions—specifically— smooth equipment from almost any location. When in test ceiling surfaces, minimal air movement,and no physical mode, Model DPU or FPI-32 upgrade kit will perform obstructions between potential fire sources and the a series of diagnostic tests without altering the detector. Do not mount detectors in close proximity to address or other stored data,allowing technicians ventilation or heating and air-conditioning outlets. to determine if the detector is operating properly. Exposed joints or beamed ceilings may also affect safe Model FP-1 1 may be installed on the same initiating spacing limitations for detectors. Should questions arise circuit with IL or ID series detectors(Photoelectric, regarding detector placement,observe National Fire thermal, or ionization), MSI-series manual stations, Protection Association (NFPA)72 guidelines. TRI-series interfaces, ICP output control devices, or CZM series of addressable, conventional-zone Dimensions modules. Diameter Base All Model FP-11 detectors can be cleaned in the field—when required — by simply removing the detector cover and unsnapping the photo chamber. T '� -�� There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush,or Overall ��" 7 replacing the labyrinth and bug screen included in 2.3" � -~� the detector maintenance kit, Model DMK-11. �( Model FP-11 uses the low-profile, surface-mounting `K. far base, Model DB-11. This base mounts on a 4-inch octagon,square, or a single-gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. The base can be used with the optional • Model LK-11 detector locking kit,which contains 50 SIEMENS Industry, Inc. Building Technologies Division Technical Data Details for Ordering Environmental Temperature: 32°F (0°C) to 100°F (38°C) Model Part Number Number Description Humidity: Up to 93% RH, non-condensing Air Pressure: No effect FP-11 500-095112 Addressable FirePrintTu Detector Alarm Temperature: 135°F (57°C) Detector Mounting Base DB-11 500-094151 For Series 11 Intelligent Detectors Electrical DB-1 1 E 500-094151E Detector Base(Small) Voltage: 16-27 VDC Air-Duct Housing(for use with Models Ripple: 3V peak-to-peak AD2-P 500-649706 FP-11,HFP-11, HFPO-11 and PE-11 Detectors) Supervisory Current: 1 10pA max Air Duct Housing(for use with Models Alarm Current: 33-50 mA AD2-XHR 500-649708 FP-11,HFP-11, HFPO-11 Detectors with Relay) ADBX-1 1 500-096181 Audible Base DB-X11 RS 500-096125 Relay Base for Series 11 Intelligent Detectors RLI-1 500-390673 Remote Alarm Indicator: 4"Octagon Box Mount,Red RLI-2 500-390674 Remote Alarm Indicator: Single-Gang Mount,Red DMK-11 500-695338 Series 11 Maintenance Kit(replacement labyrinth and bug screen) DB-ADPT 500-094187 Base Adapter to Model DB-3S Base • LK-11 1 500-695350 Base Locking Kit for Series 11 Detectors In Canada, please order: Model Part Number Number Description 135°F Fixed Temperature,Plug-In FP-11C 500-095112C Detector Addressable FirePrintTM Detector[ULC Listed] Detector Mounting Base DB-11 C 500-095687 For Series 11 Intelligent Detectors [@ULC Listed] AD-11 PC 500-095984 Air-Duct Housing[COULC Listed] DB X11 RSC 500-093125C Relay Base for Series 11 Intelligent Detectors[0:PIJLC Listed] ADBX 11C 500-096181C Audible Base for Series 11 Intelligent Detectors[(34.1LC Listed] Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. • Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 51145 L6T 5E4/Canada August 2010 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Supersedes sheet dated 5/06 Rev.U URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858