Loading...
Permit CITY OF TIGARD BUILDING PERMIT .- !Pt • COMMUNITY DEVELOPMENT Permit#: BUP2013-00281 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 01/16/2014 Parcel: 2S 101 AD03500 Jurisdiction: Tigard Site address: 6600 SW HAMPTON ST Project: Pacific Parkway Center Subdivision: WEST PORTLAND HEIGHTS Lot: Project Description: Modification to existing development, located at 6600 SW Hampton Street, includes exterior and interior alterations to the building and site work including modifications to lanscaping. loading dock and parking Contractor: LCG PENCE CONSTRUCTION LLC Owner: PACIFIC REALTY ASSOCIATES 2720 SW CORBETT AVENUE ATTN: N PIVEN PORTLAND. OR 97201 15350 SE SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-252-3802 PHONE: FAX: 503-256-3684 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: Vg Permit Fee-Additions,Alterations, 01/16/2014 $6,405 95 Demolition Occupancy Grp: B Occupancy Load: 12%State Surcharge-Building 01/16/2014 $768 71 Dwelling Units: 0 Plan Review 11/14/2013 $4,163 87 Stories: 0 Height: 18 ft Plan Review- Fire Life Safety 11/14/2013 $2,562 38 Bedrooms: 0 Bathrooms: 0 DC Provision Review,COM TI-Ping 01/16/2014 $278 00 Value: $1,100,000 DC Provision Review,COM TI-LRP 01/16/2014 $41.00 Info Process/Archiving-Lg$2.00(over 01/16/2014 $80 00 11x17) Floor Areas: Info Process/Archiving-Sm$0 50(up to 01/16/2014 $177 50 11x17) Total Area: 0 Metro Const. Excise Tax-Commercial 01/16/2014 $1,320 00 Accessory Struct: 0 Use Basement 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage. 0 Mezzanine- 0 Total $15,797 41 Required: Required Items and Reports (Conditions) Fire Sprinkler: Yes Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code State of OR Specialty Codes and all other applicable law All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days ATTENTION Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503 232 1987 or 1 800 332 2344 rr g 4-5 co C. L. P• Issued By: —� _ Permittee Signature: r .639.4175 by 7:00 a.m.for the next available inspection date.g e C b!""-g) J'. k R r PP k Cr('\ ' This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Bailai.,rtg Permit Application Commercial FOR OFFICE USE ONLY Received i k'tnurt No • / City of Tigard ‘ 1C)\/ D�� _ ,_�� j.— , , • 13125 SW Hall Blvd.,Tigard,OR Plan Rev' Phone: 503.718.2439 Fax: 503.59 �' 0,3 Date/Bv ��� tiler Permit: •, i Auk TIGARD Inspection Line: 503.639.4175 O`1 1 ek Date Reeady/B `/r See Page 1 for Internet: www.tigard-or.gov ` f±�� Nolified/Melhod: ' Supplementallnformation - I, \\ ON a.) 4}A- ,"1 'f L • a DD ❑New construction ❑ +' `! on Permit fees* are based on the value of the work performed. Indicate the value(rotnded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the work indicated on this application. Valuation: S ❑ 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder L. ocher: Number of bathrooms: ,..:,..�.,. �,_: ...:,_, �...•c: Total number of floors: JOB SITE I\FOR!►IATION AND L'OCKI 1 Job site address:6600 SW Hampton St New dwelling area: square feet City/State/ZIP:Tigard OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name:Pacific Parkway Center Covered porch area square feet 0- Cross street/directions to job site:Intersection of SW Hampton and SW 68th Deck area: square feet Other structure area: square feet REQUIRED DATA:COAl51ERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(romded to the nearest dollar)of all Tax map/parcel no.. equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF NOR work indicated on this application. EXTERIOR MODIFICATIONS,WINDOW REPLACEMENT,ENTRY MODS, Valuation: SS1,100,000.00 COMPLETE SEISMIC UPGRADE Existing building area 40680 square feet NEW OUTDOOR CONCRETE SEATING AREA New building area: 40250 square feet Number of stories: 1 Name:Pac'1'rust Type of construction: VB Address:15350 SW Sequoia Parkway Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: B Phone: (-6431624-'�76fr 003)444 43o0 Fax:(51'3) 41+- 7 755 New: B ❑ APPLICANT 0 CONTACT PERSON BUILDING PERdI[T FEES* (Please refer to feeAdsedule) Business name: I V:A Architects Structural plan review liar;(or deposit): Contact name:Aaron Cook FLS plan review fee(if applicable): Address:920 SW 6'h Ave suite 1500 Total fees due upon application: City/State/ZIP: Portland OR 97204 Amount received: Phone:(503)220-0668 Fax::( ) ;''HOTOVO, r i ,"r+LAR''AN "SY TEN1 FEES* E-mail:aaronc a tvaarchitects.com Commercial and residential prescriptive installation of CONTRACTO,1 roof-top mounted Photo Voltaic Solar Panel System. / v Submit two(2)sets of roof plan with connection details Business name: C( /44,,,e. "`�s iy„�l avv, ALL and fire department access,along with the 2010 Oregon Address: ?-'f7 GC. S'' -- _ Solar Installation Specialty Code checklist. Permit fee(includes plan review $180.00 City/State/ZIP: .r Loner_1 �,E (4 3a2 and administrative fees): Phone:(50 ) 34 q- -7,19.4_, I Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 7.r37(0 7 if/r y Total fee due upon appication: S201.60 r/4Yi1 PT C. 'rf-LT)/ sTrs-a .T1ti S, L P This permit application expires if a permit is not obtained Authorized signature:a`l' ( ...,C .-og/-- within 180 days after it has been accepted as complete. [. * Fee methodology set by Tri-County Building Industry Print name:Ra t W.4 40 J, Kitt.P ra e 0 Date: l t(tat 1 ZP() Service Board. 1:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-4613T(l 1/02/COM/W EB) COMcheck Software Version 3.9.2 irrIP Envelope Compliance Certificate 2010 Oregon Energy Efficiency Specialty Code Section 1: Project Information Project Type: New Construction Envelope Compliance Method:Simplified Trade-Off Project Title : Pacific Parkway Construction Site: Owner/Agent: Designer/Contractor: 6600 SW Hampton Street Richard Krippaehne Aaron Cook Tigarg,OR 97233 Pac Trust NA Architects 15350 SW Sequoia Parkway 920 SW 6th Ave Suite 300 Suite 1500 Portland,OR 97224 Portland,OR 97204 503.624.7755 503-220-0668 dickk @pactrust.com aaronc @tvaarchitects.com Section 2: General Information Building Location(for weather data): Portland,Oregon Climate Zone: 4c Building Space Conditioning Type(s): Nonresidential Vertical Glazing/Wall Area Pct.: 39% Skylight Glazing/Roof Area Pct.: 1% Building Type Floor Area office(Office) 39152 Section 3: Requirements Checklist Envelope PASSES:Design 3%better than code. Climate-Specific Requirements: Component Name/Description Gross Cavity Cont. Proposed Budget Area or R-Value R-Value U-Factor U-Factorcal Perimeter Roof 1: Insulation Entirely Above Deck 37312 -- 30.0 0.032 0.048 Skylight 1:Metal Frame with Thermal Break:Double Pane with 552 -- -- 0.290 0.600 Low-E,Clear,SHGC 0.27 W:Basic Wall:(E)EXTERIOR-8"CAST IN PLACE CONCRETE: 169 -- 0.0 0.570 0.150 Solid Concrete:8"Thickness,Medium Density,Furring:None W:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 1062 15.0 0.0 0.118 0.064 25"+FASCIA:Steel-Framed, 16"o.c. W:Basic Wall:(E)EXTERIOR-8"CAST IN PLACE CONCRETE 244 15.0 0.0 0.129 0.150 W/4"METAL STUD AND GWB:Solid Concrete:8" Thickness,Medium Density,Furring:Metal W:Basic Wall:(N)EXTERIOR-FLAT METAL PANEL ON(E)2X6 170 15.0 0.0 0.083 0.064 WOOD STUDS WITH GWB:Wood-Framed, 16"o.c. W: Basic Wall:(N)EXTERIOR-RIBBED METAL PANEL ON 6" 93 15.0 0.0 0.118 0.064 METAL STUDS-WITH GWB:Steel-Framed, 16"o.c. W:Basic Wall:(N)EXTERIOR-RIBBED METAL PANEL ON 6" 273 15.0 0.0 0.118 0.064 METAL STUDS-NO INTERIOR FINISH:Steel-Framed, 16"o.c. W:Basic Wall:(N)EXTERIOR-SHEAR WALL-SW 1-RIBBED 192 15.0 0.0 0.124 0.150 METAL PANEL ON 11"CAST CONCRETE W/4"METAL STUD AND GWB:Solid Concrete:11"Thickness,Medium Density, Furring:Metal Project Title: Pacific Parkway Report date: 11/08/13 Data filename:\\PDXDATA1\Data\Jobs\PacTrust.Pacific Parkway Center Bldg A.02.13.001441MechlEnvelope Code Compliance\PacTrust_ComCheck_FINAL_NOV2013.cck Page 1 of 4 W:Basic Wall:(E)EXTERIOR-BRICK ON 8"CAST IN PLACE 1860 -- 0.0 0.570 0.150 CONCRETE-WEST SIDE:Solid Concrete:8"Thickness,Medium Density,Furring:None Kawneer:Metal Frame Curtain Wall/Storefront:Double Pane with 1145 -- -- 0.420 0.450 Low-E,Clear,SHGC 0.40,PF 0.22 N:Basic Wall:(E)EXTERIOR-6"CAST IN PLACE CONCRETE: 40 - 0.0 0.650 0.150 Solid Concrete:6"Thickness,Medium Density,Furring:None N:Basic Wall:(E)EXTERIOR-BRICK ON 2X4 WOOD STUDS W/ 56 15.0 0.0 0.083 0.064 GWB:Wood-Framed, 16"o.c. N:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 42 15.0 0.0 0.083 0.064 12.5"ON 2X4 WOOD STUDS:Wood-Framed, 16"o.c. N:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 185 15.0 0.0 0.118 0.064 12.5"ON BLOCKING:Steel-Framed, 16"o.c. N:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 845 15.0 0.0 0.083 0.064 25"ON 2X4 WOOD STUDS:Wood-Framed, 16"o.c. N:Basic Wall:(N)EXTERIOR-FLAT METAL PANEL ON FURRING: 40 15.0 0.0 0.118 0.064 Steel-Framed,16"o.c. N:Basic Wall:(N)EXTERIOR-SHEAR WALL MEZZ NORTH- 1369 15.0 0.0 0.129 0.150 RIBBED METAL PANEL ON 8"CAST IN PLACE CONCRETE W/4"METAL STUD AND GWB:Solid Concrete:8" Thickness,Medium Density,Furring:Metal Kawneer:Metal Frame Curtain Wall/Storefront:Double Pane with 1190 --- --- 0.420 0.450 Low-E,Clear,SHGC 0.40 E:Basic Wall:(E)EXTERIOR-BRICK 2 WYTHS:Steel-Framed, 16" 208 15.0 0.0 0.118 0.064 o.c. E:Basic Wall:(E)EXTERIOR-BRICK ON 8"CMU-EAST SIDE: 629 15.0 0.0 0.118 0.064 Steel-Framed,16"o.c. E:Basic Wall:(E)EXTERIOR-BRICK ON 2X4"WOOD STUDS W/ 152 15.0 0.0 0.118 0.064 GWB:Steel-Framed, 16"o.c. E:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 1061 15.0 0.0 0.118 0.064 25"FASCIA:Steel-Framed, 16"o.c. E:Basic Wall:(N)EXTERIOR-FLAT METAL PANEL ON 4"METAL 17 15.0 0.0 0.118 0.064 STUDS:Steel-Framed, 16"o.c. E:Basic Wall:(N)EXTERIOR-RIBBED METAL PANEL ON 6" 41 15.0 0.0 0.118 0.064 METAL STUDS-WITH GWB:Steel-Framed, 16"o.c. E:Basic Wall:(N)EXTERIOR-SHEAR WALL-SE-RIBBED 26 15.0 0.0 0.118 0.064 METAL PANEL ON 11"CAST CONCRETE W/4"METAL STUD AND GWB:Steel-Framed,16"o.c. E:Shear Wall with metal panel(New):Steel-Framed, 16"o.c. 1417 15.0 0.0 0.118 0.064 Kawneer:Metal Frame Curtain Wall/Storefront:Double Pane with 1223 -- -- 0.420 0.450 Low-E,Clear,SHGC 0.40 S:Basic Wall:(E)EXTERIOR-BRICK ON 8"CMU-EAST SIDE: 192 -- 0.0 0.570 0.150 Solid Concrete:8"Thickness,Medium Density,Furring:None S:Basic Wall:(E)EXTERIOR-STANDING SEAM METAL PANEL 674 15.0 0.0 0.118 0.064 25"ON 2X4 WOOD STUDS:Steel-Framed, 16"o.c. S:Basic Wall:(N)EXTERIOR-FLAT METAL PANEL ON(E)2X6 40 15.0 0.0 0.083 0.064 WOOD STUDS WITH GWB:Wood-Framed,16"o.c. S:Basic Wall:(N)EXTERIOR-FLAT METAL PANEL ON(N)2X6 13 15.0 0.0 0.083 0.064 WOOD STUDS WITH GWB:Wood-Framed,16"o.c. S:Basic Wall:(N)EXTERIOR-RIBBED METAL PANEL ON 6" 88 15.0 0.0 0.083 0.064 METAL STUDS W/GWB:Wood-Framed, 16"o.c. S:Basic Wall:(N)EXTERIOR-SHEAR WALL-SW 2-RIBBED 1600 15.0 0.0 0.122 0.150 METAL PANEL ON 16"CAST IN PLACE CONCRETE W/4"METAL STUDS AND GWB:Solid Concrete:12" Thickness,Medium Density,Furring:Metal Kawneer:Metal Frame Curtain Wall/Storefront:Double Pane with 1383 -- --- 0.420 0.450 Low-E,Clear,SHGC 0.40 Floor 1:Slab-On-Grade:Unheated 1160 -- -- -- -- (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Fenestration Product Rating: ✓ 1. U-factors of fenestration products(windows,doors and skylights)are determined in accordance with NFRC 100 by an accredited, independent laboratory,and labeled and certified by the manufacturer or are determined using the commercial size category values listed in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.4 and shall include the effects of the window frame. The temporary label afixed to the fenestration products must not be removed prior to inspection. Project Title: Pacific Parkway Report date: 11/08/13 Data filename:IIPDXDATA11Data\Jobs\PacTrust.Pacific Parkway Center Bldg A.02.13.001441Mech\Envelope Code Compliance/PacTrust_ComCheck_FINAL_NOV2013.cck Page 2 of 4 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONT Plans reference page/section: 08 62 00 UNIT SKYLIGHTS • 2. Solar heat gain coefficient(SHGC)of glazed fenestration products(windows,glazed doors and skylights)shall be determined in accordance with NFRC 200 by an accredited,independent laboratory,and labeled and certified by the manufacturer or be determined using the Solar Heat Gain Coefficients(SHGC)in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.10.The overall values must consider type of frame material and operator for the SHGC at normal incidence. 08 80 00 GLASS AND GLAZING Plans reference page/section: 08 62 00 UNIT SKYLIGHTS Air Leakage, Insulation, and Component Certification: • 3. Sealing of the building envelope.Openings and penetrations in the building envelope are sealed with caulking materials or closed with gasketing systems compatible with the construction materials and location.Joints and seams are sealed in the same manner or taped or covered with a moisture vapor-permeable wrapping material.Sealing materials spanning joints between construction materials allow for expansion and contraction of the construction materials. 07 21 00 BUILDING INSULATION Plans reference page/section: 07 92 00 JOINT SEALANTS J 4. Window and door assemblies.The air leakage of window and sliding or swinging door assemblies that are part of the building envelope are determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440,or NFRC 400 by an accredited,independent laboratory,and labeled and certified by the manufacturer. Plans reference page/section: 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONT • 5. Curtain wall,storefront glazing and commercial entrance doors.Curtain wall,storefront glazing and commercial-glazed swinging entrance doors and revolving doors are tested for air leakage in accordance with ASTM E 283.For curtain walls and storefront glazing, the maximum air leakage rate is 0.3 cubic foot per minute per square foot of fenestration area.For commercial glazed swinging entrance doors and revolving doors,the maximum air leakage rate is 1.00 cfm/ft2 of door area. Plans reference page/section: 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONT • 6. Building thermal envelope insulation.An R-value identification mark is applied(by manufacturer)to each piece of insulation 12 inches or greater in width.Alternately,the insulation installers have provided a signed,dated and posted certification listing the type, manufacturer and R-value of insulation installed.Refer to code section for blown or sprayed insulation installation/settling depths and marker requirements. • 7. Insulation mark installation.Insulating materials are installed such that the manufacturer's R-value mark is readily observable upon inspection. ✓ 8. Insulation product rating.The thermal resistance(R-value)of insulation has been determined in accordance with the U.S.FTC R-value rule. • 9. Installation.All material,systems and equipment are installed in accordance with the manufacturer's installation instructions and the International Building Code. • 10.Outdoor air intakes and exhaust openings.Stair and elevator shaft vents and other outdoor air intakes and exhaust openings integral to the building envelope shall be equipped with not less than a Class I motorized,leakage-rated damper with a maximum leakage rate of 4 cfm per square foot at 1.0 inch water gauge when tested in accordance with AMCA 500D.Stair and shaft vent dampers shall be capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. Plans reference page/section: SEE DEFERRED SUBMITTAL • 11.Loading dock weatherseals.Cargo doors and loading dock doors are equipped with weather seals to restrict infiltration when vehicles are parked in the doorway. Plans reference page/section: 08 36 00 SECTIONAL OVERHEAD DOORS ✓ 12.Recessed lighting.Recessed luminaires installed in the building thermal envelope are sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires are IC-rated and labeled as meeting ASTM E 283.All recessed luminaires are sealed with a gasket or caulk between the housing and interior wall or ceiling covering. Plans reference page/section: REQUIREMENT IS NOT APPLICABLE ❑ 13.Vestibules.Doors that separate conditioned space from the exterior are protected with an enclosed vestibule,with all doors of the vestibule equipped with self-closing devices.Vestibules are designed so interior and exterior doors to not operate simultaneously. Exception(s): ❑ Doors not intended to be used as a building entrance door,such as doors to mechanical or electrical equipment rooms. ❑ Doors opening directly from a sleeping unit or dwelling unit. ❑ Doors that open directly from a space less than 3000 sq.ft.in area. ❑ Revolving doors. ❑ Doors used primarily to facilitate vehicular movement or material handling and adjacent personnel doors. XRequirement is not applicable. Plans reference page/section: Project Title: Pacific Parkway Report date: 11/08/13 Data filename:\\PDXDATA11Data\Jobs\PacTrust.Pacific Parkway Center Bldg A.02.13.00144\Mech\Envelope Code Compliance\PacTrust_ComCheck_FINAL_NOV2013.cck Page 3 of 4 14'Other components have supporting documentation for proposed U-Factors. Requirement is not applicable. Plans reference page/section: Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed envelope system has been designed to meet the 2010 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 3.9.2 and •comply with the m.ndatory requirements in the Requirements Checklist. Aaron Cook AIA LEED BD+C �� 11/08/13 Name-Title Signa re Date Project Title: Pacific Parkway Report date: 11/08/13 Data filename:\\PDXDATA1\Data\Jobs\PacTrust.Pacific Parkway Center Bldg A.02.13.001441Mech\Envelope Code Compliance\PacTrust_ComCheck_FINAL_NOV2013.cck Page 4 of 4