Plans 1 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING I LIJ AC ALJERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE Ct;AC CONCRETE HAZARDS PER ART. 690.17. OCT 2 4 2013 DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY CITY OFTIGARD (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. CITY OF�TIIGARD BUILDING OTI jIO�( � EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING Approved �X.A1-- [ Li' GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN Conditionally Approved [ GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL See Letter to:Follow [ ] HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) Atta hed [ I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER PermitNum' 24:1 C-Y7u Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Addr- • •' 0r ' ' .:.11�LA Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC By: AiA,f Date: D M kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN Approved plans LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY shall be on job site. MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NTS NOT TO SCALE UL-LISTED LOCATION PROVIDED BY THE OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING OFFICE COPY PL PROPERTY LINE HARDWARE. P01 POINT OF INTERCONNECTION 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS AND SCH SCHEDULE GROUNDED AT THE MAIN ELECTRIC PANEL. SS STAINLESS STEEL 9. THE DC GROUNDING ELECTRODE CONDUCTOR STC STANDARD TESTING CONDITIONS SHALL BE SIZED ACCORDING TO ART. 250.166(B) & TYP TYPICAL 690.47. UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT VICINITY MAP INDEX Sw'l able'St .. -'_�,1 `2�Calu5 UrThprOOK'U th! -4 ....-w, }1��1►,-,; PVl COVER SHEET . • C'V: "�r- `af a t, • -•tr• Sw'BE PV2 SITE PLAN ' a f Q "':"r' ' . PV3 STRUCTURAL VIEWS rt - . - • n-: r,.�.rl PV4 UPLIFT CALCULATIONS• LICENSE GENERAL NOTES `a- - PV5 THREE LINE DIAGRAM -iL ___ i '`, ;,� Cutsheets Attached OR 180498 1. THIS SYSTEM IS GRID-INTERTIED VIA A Church of Jesus 't,$• !� t ' ��O �.s RGC, CGC1 UL-LISTED POWER-CONDITIONING INVERTER. Christ of LDS" ' ;' ;- 0.-< + xi -R d+os 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 4_ ! #n. .;,' -1.` Sw 3. SOLAR MOUNTING FRAMES ARE TO BE f '� • , •;� 'i St ,t GROUNDED. i,a 0t As s.ae 01 ;ti 1�► , ' 4. ALL WORK TO BE DONE TO THE 2010 OBC 0,, �` (JI MODULE GROUNDING METHOD: SLEEKMOUNT BASED ON THE 2009 IBC. Tigard Church ♦ �y�/, !y 5. ALL ELECTRICAL WORK SHALL COMPLY WITH of Goad �A- '*14b � 8 REV BY DATE COMMENTS AHJ: Tigard THE CURRENT NATIONAL ELECTRIC CODE AS - r p • fir` AMENDED BY THE OREGON ELECTRICAL SPECIALTY of ' Sip ' ,� a,. Cn //5. t4 10i4i2013 CHANGED MODULE TYPE DUE TO INVENTORY ' UTILITY: Portland General Electric (POE) CODE. • -H f , G e 0/) ,%... ' e ®© « rf I eevo,, fiend O egon, St4te of ator4 Geploaic $ v imm- . J B-9721 48 7 0 0 PREMISE 0 R OI � DESPTIDN: ° ": CONFIDENTIAL - THE INFORMATION HEREIN tae NUMBER: PEARL, WILLIAM PEARL RESIDENCE Aaron Banks BENEFIT OF SHALL NOT EXCEPT BE USED FOR THE Soiar( ity BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �����` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15648 SW SUMMERFIELD LN 5 KW PV Array '�� PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIItE (20) TRINA SOLAR # TSM-250PA05.18 3055 pea*. Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAIE: SHEET: REV: DATE San Mateo, CA 94402 "�10N OF SOLARCITY "G 5035269460 T:(650)638-1028 F:(650)638-1029 POWER-ONE AURORA PVI-4.2-OUTD-S-US COVER SHEET PV 1 a 10/4/2013 (888)-91-CITY(765-2489) .rr.aoladty.cam PITCH: 18 ARRAY PITCH:18 ✓ MP1 AZIMUTH:215 ARRAY AZIMUTH: 215 co -0a MATERIAL: Comp Shingle STORY: 1 Story a, - - Y Ua O 4 J Ca a Un-Locked Gated 0 0 0 0 ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS LOCATED WITHIN 3 FEET OF A ROOF EDGE,HIP,EAVE OR RIDGE, • 'DSISC 305..3(B) LEGEND 12" ire Setback . ! O (E) UTILITY METER & WARNING LABEL ❑ 0 0 0 0 ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS 3 0 0 �� DC DISCONNECT & WARNING LABELS • 3 0 O O AC F AC DISCONNECT & WARNING LABELS 0 0 < TOTAL ARRAY AREA (SF): 2555 0 JUNCTION BOX N of o o TOTAL ROOF AREA (SF): 316 TOTAL ARRAY AREA IS RI 12.3 O DC COMBINER BOX & WARNING ___ 0 PERCENT OF TOTAL ROOF AREA .,© r--_ Inv ; - 0 DISTRIBUTION PANEL & WARNING I ' D 1 A LG 1 ` _- PV3 LOAD CENTER & WARNING LABELS ((M) ODEDICATED PV SYSTEM METER — CONDUIT RUN ON EXTERIOR - CONDUIT RUN ON INTERIOR GATE/FENCE Front Of House --- INTERIOR EQUIPMENT SITE PLAN Scale: 1/8" = 1' f�, 0 1' 8' 16' 4 I I S i I CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER J B-9 721 487 00 PREMISE OWNER: DESCRIPTION: -DESIGN: *4j4' CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM PEARL RESIDENCE Aaron Banks BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM /',,,`SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15648 SW SUMMERFIELD LN 5 KW PV Array '�� PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION MATH WODUES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 aervew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN WVERER PAGE NAPE SHEET: REY: DATE: San Mateo, CA 94402 PER`"�'DN OF CITY INC 5035269460 T:(650)638-1028 F:(650)638-1029 POWER-ONE # AURORA PVI-4.2-OUTD-S-US SITE PLAN PV 2 a 10/4/2013 (888)—SQL—CITY(765-2489) unre.solarcity.com �1 (E) 2x4 0 .- `` g'1 0--0 �` t 2' ■ -2" 5'-7" / 6'-8" / 6'-8" / (E) LBW SIDE VIEW OF MP1 RAFTER: (E) 2x4 ® 24" O.C. A NTS CEILING JOIST: (E) 2x4 © 24" O.C. MAX SPAN: 6'-8" STRUCTURE MEETS THE MAX LANDSCAPE STANDOFF X—SPACING: 72" O.C. (STAGGERED) PRESCRIPTIVE REQUIREMENTS - DF #1 CARPENTER BUILT TRUSSES OF THE OSISC SECTION 305.4 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS ! LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH ZEP COMP MOUNT C (4) (2) POLYURETHANE SEALANT. ;�.erAl N NYMi r i•ZEP FLASHING C <��T�� (3) INSERT FLASHING. (E) COMP. SHINGLE v iiiI ���`i (4) PLACE MOUNT. (E) ROOF DECKING 1.11M1 INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (5) WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER STANDOFF $j; Scale: 1 1/2" = 1' CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9 7 2148 7 00 PREMISE OMNER: DESCRIPTION: -DEgpt =,,4 CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM PEARL RESIDENCE Aaron Banks BENEFIT SHALL OF IT ANYONE DI EXCEPT INI HOLE INC., MOUNTING Comp SYSTEM: Mou r I,I„`SolarCity NCR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15648 SW SUMMERFIELD LN 5 KW PV Array 'i PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MDOUES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 aae. r SO ARCITY EOINPMENT, WITHOUT THE WRITTEN INVERTER PACE NAME SHEET: REV GATE: T:(650)638-1028 CA 6�638-1029 PERMISSION OF SOEARCITY INC. POWER—ONE # AURORA PVI-4.2—OUTD—S—US 5035269460 STRUCTURAL VIEWS PV 3 a 10/4/2013 (888)-sa-CITY(765-2489)en.sdaraty.com UPLIFT CALCULATIONS 07.30.2013 SolarCity SleekMount' PV System Version#13.5 Structural Design Software Project Information Risk Category II PV System Type SolarCity SleekMount"" Comp Roof Comp Roof #of Layers 1 Roof Slope 18° Rafter Spacing 24"O.C. PV Module Orientation Landscape Total Area of Array 352 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C Calculation Of Reduced Roof Snow Loads Ground Snow Load Pg 25.0 psf 'ASCE Table 7-1 Surrounding Roof Snow 70% 17.5 psf ' ASCE Eq: 7.4-1 Roof Snow Over PV Modules 700/0 17.5 psf ' ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category B Section 6.5.6.3 Roof Style Gable/Hip Roof 'N.6-11B/C/D-14A/B Mean Roof Height h 18 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.70 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(VA2)(I) 13.7 psf Equation 6-15 Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Rg.6-118/C/D-14A/B Ext. Pressure Coefficient(Down) _ GCp(Down) 0.45 Rg.6-11B/C/D-14A/B Design Wind Pressure p p =qh(GCp) Equation 6-22 Wind Pressure Up p(up) -12.0 psf Wind Pressure Down j p(down) 10.0 psf Allowable Attachment Spacings(In.) X-Direction I Y-Direction Max Allowable Foot Spacing Landscape 72" l 39" Max Allowable Cantilever _ Landscape 24" NA Max Standoff Tributary Area TribCL 20 sf PV Assembly Dead Load WPV 3 psf Net Wind Uplift at Attachment TCL -202 lbs Uplift Capacity of Attachment Tallow 637 lbs Attachment Demand/Capacity DCRLand 31.6% CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER J B-9 7 2148 7 00 PREMISE OMER DESA' DESIGN: ��f, CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM �:I"9 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MDIINTNIG SYSTEM PEARL RESIDENCE Aaron Banks �- - PAR SHALL IT BE DISCLOSED THE ECI WHOLE E DR IN Comp Mount Type C 15648 SW SUMMERFIELD LN 5 KW PV Array 1���SolarCity PART IZ TO OTHERS OUTSIDE THE ECTION MT TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH MOUES: THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 ClecrAew Way 440 SOLARCITY EQUIPMENT, NI7HWT THE WRITTEN INVERTER PACE NAYS SHEET REV DAIS San Mateo CA 94402 PERMISSION OF soLARCITY INC. POWER-ONE # AURORA PVI-4.2-OUTD-S-US 5035269460 UPLIFT CALCULATIONS PV 4 a 10/4/2013 T:(650)638-1028 F:(650)638-1026 (888)-SOL-CITY(765-2489)....solorcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO TWO (N) GROUND Panel Number: FPE Inv 1: DC Ungrounded INV 1 —( 1 )POWER-ONE # AURORA PV1-4.2-OUTD-S-US —(20)TRINA SOLAR TSM-250PA05.18 OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24562719 Inverter; Zigbee 4200W, 277V/240V/208V, 96%/96 /95% PV Module; 250W, 227.5W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 INV 2 Voc: 37.6 Vpmax: 30.3 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (N) 200A MAIN SERVICE PANEL (N) 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND (E) WRING COOPER 200A/2P Meter Socket 0) POWER-ONE n Q DC.DO NOT ADJUST MIN.ACTIVATION V TAGS A AURORA PV1-4.2-OUTD-S-US DC_ y 1 Stnng(s)Of 10 On MP 1 4 eR (E) LOADS /A f / I ',1:! n / /� L1 140V I- 1}-- EGC l I • • • I L2 GFP/GFCI 4r----- DC, I N IN 14 (N)25A/2P �_ GND� EGC/ •_---_DC. I 2 DC. DO NOT ADJUST MIN.ACTIVATION V TAGS-A le n v GEC 0 _...___- DC- DC- 1 Stnng(s)Of 10 On Me 1 GND I____EGC —- _ EGC (1)Conduit i Condu t K t, 3/4 EMT N J EGC/GEC-j o - z-z GEC r -I TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I1 I I I I I I I I I — - POI-(2)Ground Rod; 5/B' x 8', Copper A —(1)COOPER /8-Line Meter Socket 011 —(1)CUTLER-HAMMER /BR225 Meter Socket; 125A, 4-14AWC, Ring Type AC DC Breaker; 25A/2P, 2 Spaces —(1)AW CAP; B-Line Meter Socket Accessory (1)AITG 11#100, THWN , ack -- (1)A: THYM-2-2, RBred (2)A•G/10.PV 111K Black Voc =412.1 VDC Isc =8.85 ADC (1)AWG /l0, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC O (1)AWG/10, Solid Bare Coppv EGC Vmp =303 VDC Imp=8.27 ADC —(1)AK/6, THAN-2, Green EGC/GEC —(1)Conduit Kit; 3/4'EMT (1)Conduit Nit 3/4'EMT E(2)AWG/10, PV WIRE, &ack Voc =412.1 VDC Isc =8.85 ADC 2 �(1)AWG/10, Sdid Bare Copper EGC Vmp =JO,j VDC Imp=8.27 ADC (1)Conduit Kit; 3/4'EMT CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9 7 214 8 7 00 PREMISE OWNER: DESCRIPTION: CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM PEARL RESIDENCE Aaron Banks R.. BENEFIT OSHALL OF IT BE DISCLOSED EXCEPT IN ICE INC., MOUNTING Comp SYSTEM: SoiarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 15648 SW SUMMERFIELD LN 5 KW PV Array ►� ORGANIZATION, EXCEPT IN CONNECTION WITH MOD-It-ES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 aearvie.Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. 5035269460 T:(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVT-4.2—OUTD—S—US THREE LINE DIAGRAM PV 5 a 10/4/2013 (888)-501-CITY(765-2489).,...solarcity.con, 1. Conductor Sizing per Art 690.8(A) a. Conductor must have 30 deg. C ampacity >= 125% of continuous ELECTRICAL CALCULATIONS current. b. Conductor must have (after corrections for conditions of use) >= Module: 20 Trina TSM-250PA05.08 Black 227.5 Inv Pwr W PTC Strien Voltage Drop Calculations Version 5_9.11 . continuous current per Table 310.16. Inverter 1: 1 Power-One PVI-4.2-S 96.0% 4,600 4,368 10 Vdrop= (Imp) • (2•Length)"(Resistance) / (Vmp) Module: Imp(A) Max. Length(ft) Wire c. Evaluate conductor temperature at terminations per 110.14(C). Inverter 2: String: 8.27 80 C AWG 10 at Max Ave Hi: 60 deg F Module: Vdrop= (8.27 A • 160 It •0.00124 Ohms) / 279 V= 0.59% Ampacity of wire derated for conditions of termination must be >= Inverter 3: Branch: 8.27 I 0 I C AWG 10 at Max Ave Hi: 80 deg F continuous current*1.25. All string terminations are rated at 90' C. Module: Vdrop= (8.27 A • 0 ft •0.00124 Ohms) / 279 V= 0.00% Inverter 4: Total voltage drop in DC conductors= 0.59% 2. OCP Sizing per Art 690.8(8)(1) Inverter: 20.00 I 10 1 C AWG 10 at 240V a. Round up to next size per Art 240.4(B) Total: 20 modules Total Inv Pwr 4,600 4,368 PTC Vdrop= (20.00 A • 20 ft *0.00120 Ohms) / 240 V 0.20% Photovoltaic Module Electrical Specifications: Total STC 5,000 Combined 20.00 I 0 1 E AWG 06 at 240V 3. Conductor Sizing per Art 690.8(A) Voc= 37.6 V deg F deg C Vdrop= (20.00 A • 0 ft •0.00049 Ohms) / 240 V 0.00% a. Conductor must have 30 deg. C ampacity >= 125% of continuous Vmp= 30.3 V Record Low Temp: 8 -13.3333333 Total voltage drop in AC conductors= _ 0.20% Isc= 8.85 A Max Average Hi Temp: 80 26.66666667 Total voltage drop in AC and DC conductors= 0.79% current. Imp= 8.27 A Record Hi Temp: 106 41 Tvoc= -0.12032 V/deg C Power-One Strings: Individual MPPT b. Conductor must have (after corrections for conditions of use) >= Tisc= 4.1595 mA/deg C I continuous current per Table 310.15(B)(16). String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1-way wire length: 0 ft Power-One PVI-4.2-S 1 strings per branch 1 1 strings per branch 2 C. Evaluate conductor temperature at terminations per Art 110.14(C). 10 Trina TSM-250PA05.08 Black Inverter Min Vdc Input: 120 Vdc 10 modules per series string 10 modules per series strin' Voc= 376 V Min Vmp at Max Temp: 236 Vdc Voc= 376 V 376 V Ampacity of wire derated for conditions of termination must be >= Vmp= 303 V Max Voc at Min Temp: 422 Vdc Vmp= 303 V 303 V continuous current*1.25. All branch terminations ore rated at 75' C isc= 8.85 A Inverter Max Vdc Input: 600 Vdc Isc= 8.85 A 8.85 A min. Imp= 8.27 A Max String Size. 14 Imp= 8.27 A 8.27 A Icont= 11.06 A Art 690.8(A)(1) 1-way wire length: 80 ft Icont= 11.06 A 11.06 A Art 690.8(A)(1) 4. OCP Sizing 1.a conductor. C AWG 10 PV Wire 2.a Conductor 1:C AWG 10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 2:C AWG 10 PV Wire Conductor 1: Conductor 2: 5. Conductor Sizing per Art 690,8(A) Icont•1.25= (Amps) 13.83 Icont•1.25=(Amps) 13.83 13.83 a. Conductor must have 30 deg. C ampacity >= 125% of continuous 30 deg C ampacity= 40 30 deg C ampacity= 40 40 1.b Icont=(Amps) 11.06 2.b Icont=(Amps) 11.06 11.06 Current. Start ampacity 40 Start ampacity 40 40 Temperature derate(%=F) 0.71 Temp. derate(%=F) 0.71 0.71 b. Conductor must have (after corrections for conditions of use) >= Conduit fill derate(%=#) 1 Cndt. fill derate(°/a=#) 0 8 0.8 continuous current per Table 310.15(8)(16). Derated ampacity 28.40 I Derated ampacity 22.72 22.72 Term 1 Term 2 c. Evaluate conductor temperature at terminations per Art 110.14(C). 1.c Icont*1.25= (Amps) 13.83 Temp table 75degC 75degC Ampacity of wire devoted for conditions of termination must be >= Ampacity 40 2.c Icont•l.25= (Amps) 13.83 13.83 * Ampacity 35 35 continuous current 1.25. All inverter output terminations are rated at 1.d Icont•1.25= (Amps) 13.83 2.d EGC C AWG 10 C AWG 10 Art. 250.122 75' C. OCP size= 15 OCP size= 15 15 6. OCP Sizing Inverter Type A Output Combined Inverter Output a. Round up to next size per Art 240.4(B) Power-One PVI-4.2-S 1-way wire length: 10 ft Service Voltage= 240 Volts Icont= 20.00 A Art 690.8(A)(1) Total Inverter Power= 4,600 Nameplate Watts 1-way wire length: 0 ft 7. Conductor Sizing per Art 690.8(A) 3.a Icont'1.25=(Amps) 25.00 A Art 690.8(B)(1) Icont=#of inverters•max inverter current Art 690.8(A)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous OCP size= 25 A Art. 240.6(A) Icont= (Amps) 20.00 3.b Conductor C AWG 10 THWN-2 at 90 deg C: Table 310.16 4.a Icont`1.25= (Amps) 25.00 A All 690.8(B)(1) current. Icont•1.25= (Amps) 25.00 OCP size= 25 A Art. 240.6(A) 30 deg C ampacity = 40 4.b Conductor E AWG 06 THWN-2 at 90 deg C: Table 310.16 b. Conductor must have (after corrections for conditions of use) >= 3.c Icont= (Amps) 20.00 Icont• 1.25= (Amps) 25.00 continuous current per Table 310.15(B)(16). Start ampacity 40 30 deg C ampacity= 75 I_ Temperature derate(%=F) 0.91 4.c Icont=(Amps) 20.00 c. Evaluate conductor temperature at terminations per Art 110.14(0). Conduit fill derate(°ia=#) 1 Start ampacity 75 Derated ampacity 36.4 1 Temp. derate(%=F) 0.91 Ampacity of wire derated for conditions of termination must be >= 3.d Icont•1.25= (Amps) 25.00 Cndt. fill derate(%=#) 1 continuous current 1.25. All inverter output terminations are rated at Ampacity 35 1 Derated ampacity 68.25 I 75' C min. 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3),250.166(B) 4.d Icont*1.25= (Amps) 25.00 Ampacity 65 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9721487 00 PREMISE OWNER. D E S C R I P T I O N: DESIGN: +�,,4I CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM PEARL RESIDENCE Aaron Banks �,,�,; BENEFIT OF ANYONE CLOSED IN MOLE INC., Comp 15648 SW SUMMERFIELD LN �i SoIarity NOR SHALL IT BE DISCLOSED IN YMOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 5 KW PV Array ORGANIZATION, EXCEPT IN CONNECTION WITH Ml>u aES TIGARD, OR 97224 a�e. Way THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 ae SOLARCITY EQUIPMENT, 'WITHOUT THE MTRITTEN WVER PAGE NAME: SHEET: RN DATE: San Mateo,CA 94402 PERMISSION OF soLARarr INC. POWER-ONE # AURORA PVI-4.2-OUTD-S-US 5035269460 ELECTRICAL CALCULATIONS PV 6 a 10/4/2013 (�)Sa-prYi 6258-2�)s.w: I=ty.com CAUTIO N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 15648 SW Summeeld Ln INVERTER AND ,r DC DISCONNECT it O ol UTILITY • SERVICE SOLAR 0 PHOTOVOLTAIC ON ROOF PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS A/C DISCONNECT PER NEC 690.17 - OPERATING VOLTAGE = 240V MAX CURRENT = 19.17 A CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9721487 00 PREI SE OMER. DESCRIPTION. DESIGN: `%64,4, CONTAINED SHALL NOT BE USED FOR THE PEARL, WILLIAM PEARL RESIDENCE Aaron Banks ... - NOR BENEFIT OF IT ANYONE DI EXCEPT IN INC., Comp SYSTEM: 15648 SW SUMMERFIELD LN ��� SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 5 KW PV Arra PART TO OTHERS OUTSIDE THE RECIPIENT'S MOIXREP �' TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE Of THE RESPECTIVE (20) TRINA SOLAR # TSM-250PA05.18 3055 Geame•War SOLARCITY EQUIPMENT, WTHOUT THE WRITTEN PACE NAME: SHEET: REV: DATE: San Mateo, CA 94-402 PERMISSION OF SOLARaTY INC 5035269460 T:(65o)636-1028 F:(650)638-1029 POWER—ONE # AURORA PV1-4.2—OUTD—S—US SITE PLAN PLACARD PV 7 a 10/4/2013 (888M5413.-) 888)-soL CITY(765-2189)rn.sdarclty.aam Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC _ A (AC) (POI) CAUTION (P01) . Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE : Per Code: CA Fire Guidelines MAXIMUM AC _ NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC) (INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) (POI) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- A (DC) (INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED MAXIMUM POWER--v NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEM v Label b Location: VOLTAGE(Voc)_ WARNING (AC) (P01)Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD 17 NEC 690. 4 DO NOT TOUCH TERMINALS ( ) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.8.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC _ A OPERATING CURRENT (AC):AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC V (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit La La (POI) (INV): Inverter With Integrated DC Disconnect CAUTION (LC): Load Center Per Code: Utilit Meter PHOTOVOLTAIC SYSTEM NEC 690.64.B.4 (M): Y CIRCUIT IS BACKFED (P01): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR vi O4 THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED } IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set I ����'� 3055 view Way �� San Mateo,CA 94402 ���� T:(650)638-1028 F9)ew .solar 29 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Soiar( ity /� (888)-SOL-CRY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. • ZS Comp Edge Zone Calculations 1 of 4 I ZS Comp Edge Zone Calculations 2 of 4 Zep S o la r 5/28/13 Zep S o la r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load the design variables to account for the worst case for each failure mode that is being down force spacing = calculations will vary g g module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed = 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load = 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs g4.F1 note:use 10 psf minimum •�► .,� Snow Calculations Air Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing P OREGON lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load -e-,.. �. �� above 30 degrees. uplift spacing = cur Roo - module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 p=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 K,K„Kd Vz I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Exposure= C Roof Zone= Edge Zone Down Force Load Roof Pitch Combinations: 14 30 Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof K21= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 _ 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape down force spacing = 114716s x 144 to = 130" ortrait effective area= 21.7 ft2 39"x 32.46psf ftZ Plandscape= -30.79 psf q = 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ftZ = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs landscape uplift spacing = 39"x 29.05 psf x 144 in = 83" 656 lbs in portrait uplift spacing = 65"x 27.12 psf x 144 ftZ = 54" • ZS Comp Edge Zone Calculations 3 of 4 $ ZS Comp Edge Zone Calculations 4 of 4 Zep Solar 5/28/13 Zep Solar 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing =-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273 =73" PS=C,pf Roof Pitch= 31 45 degrees pf=0.7CeCiI pe Ce= 0.9 C = 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing = -1.7917 x 32.46 psf+118.58=60" I= 1.0 Ps= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° 27° 30° Lateral 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". a lateral spacing _ 292.49 in landscape p g 39"x 14.49 psf x 144 ftz =74" portrait lateral spacing 292169 in p acin p g _ 65"x 14.49 psf x 144 ftz =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2921bs in portrait lateral spacing = 65"x 13.50 psf x 144 ftz =48" • • SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed is optimized to achieve superior strength and Zep Compatiblerm modules Installation Instructions aesthetics while minimizing roof disruption and labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL 1 Drill Pilot Hole of Proper Diameter for mounting clamps,combined with the addition listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 21 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" utilizes Zep Compatible"' modules with 40 Insert Comp Mount flashing under upper •Ground Zep UL and ETL listed to UL 467 as ``' layer of shingle strengthened frames that attach directly to grounding device ` Zep Solar standoffs,effectively eliminating the 4 Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition shingles are not required to be cut for this •Anodized components for corrosion resistance 5. Install lag pursuant to NDS Section 11.1.3 system, allowing for minimal roof disturbance. •Applicable for vent spanning functions with sealing washer. ifix 6 Secure Leveling Foot to the Comp Mount using machine Screw (rtit' ® Place module ,� A Components B �� — 5/16"Machine Screw Alan" 8 Leveling Foot er ^+ 4 C Lag Screw ® i .1171:11.gt D Comp Mount 4411111' "01 C Comp Mount Flashing i •.- ��_ - D 0� .; 1111.111/ E b V . Y�pNP�re� SolarCity January 2013 4/ LISTED SolaiC'ty January 2013 �ONP.t` J ry . , sower-one= AURORA ` . . /Renewable Energy Solutions TECHNICAL DATA VALUES PVI-3.0-OUTD-US 1 PVI-3.6-OUTD-US PVI-4.2-OUTD-US Nominal Output Power W 3000 3600 4200 Maximum Output Power W 3000 3300• 3300" 3600 4000• 4000" 4200 I 4600". 4600'• 0 Rated Grid AC Voltage V 208 240 277 208 240 277 204 • 240 277 Z Input Side(DC) = Number of Independent MPPT Channels 2 2 2 P`Y''—Soo—TL rQ Maximum Usable Power for Each Channel W 2000 3000 3000 Absolute Maximum Voltage(Vmax) V 600 600 600 0 Start-Up Voltage(Vstart) V 200(adj.120-350) 200(adj.120-350) 200(adj.120-350) 131/1-3.6—TI D Full Power MPPT Voltage Range V 160-530 120-530 140-530 Q Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7xVstart-580 Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 P`'lI-4 2—TI Maximum Usable Current per Channel A 10 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20 20 Number of Wire Landing Terminals Per Channel 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Output Side(AC) Terminal bock Pressure Clamp,AWG10 AWG4 OUTDOOR MODELS '"'• Grid Connection Type 10/2W 0�W 10/2W 10/2w 0/W 10/2W 10/2W 0/3W''' ,gam t •- Q -"t Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244304 183-228 211-264 244304 ..,�..�_.-..Y., . Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 5740.5 57-60.5 57-60.5 Maximum Current(lacmax) Aims 14.5 14.5 12 172 16 16 20 20 20 The most common residential inverter is the ideal size for an average d t : Power Factor >0.995 >0.995 >0.995 sized famil home. This famil of sin le hase strip inverter r c• TotaI Harmonic Distortion At Rated Power j % <2 <2 <2 Y y g p string ! < '- Grid Wiring Termination Type 1 Terminal block,Pressure Clamp,AWGI O-AWG4 limenesmenemmessustreengemesparsm- 97 Protection Devices complements the typical number of rooftop solar panels,allowing :, r home-owners to get the most efficient energy harvesting for the , Input ' Reverse Polarity Protection Yes Yes Yes size of the property.This rugged outdoor inverter has been designed Over-voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel as a completely sealed unit to withstand the harshest environmental PV Array Ground Fault Detection Pre start-up Riso and dynamic GFOI(Requires Floating Arrays) output conditions. Anti-Itlanding Protection Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 requirements requirements requirements Over-Voltage Protection Type Varistor,2(Li-Lr/L,-G) Varistor,2(I.,-L/L,-G) Varistor,2(L,-Lt/L,-G) One of the key benefits of the Uno family of single-phase inverters MaximumACOC` PD 20 A 20 15 25 20 20 25 25 25 is the dual input section to process two strings with independent Ef6ci.ncy - Maximum Efficiency % 96.9 97 97 MPPT especially useful for roofto p installations•[ions w-th two different wcEf6a.ncy % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time Operating Performance = Stand-by Consumption W <8 <8 - power tracking and improved energy harvesting. <B ., "- Night time consumption W. �- --l<0.6� <0.6 <0.6 Communication -!"_ '11111111111111[1 The transformerless operation gives the highest efficiency of up to userinterface 16 characters xz lines LCD display Remote Monitoring(1x115485 incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable to 9 P-) PVI-USB-R5485_232(opt),PVFDESKTOP(opt) Wired Local 91xRS48Slnd,1 I _—__ __--__ low power installations with reduced string size. Wireless Local Monitoring PVI DESKTOP(opt)with PVI-RADpMODULE(opt) Environmental . I . - Ambient Air Operating Temperature Range rt('Cl -13 to+140(-25 to+60)with -13 to+140(-2550+60)with -13 to+140(-25 to+60)with • derating above 131(55) derating above 131(55) derating above 113(45) Ambient Air Storage Temperature Range I 'F("g -40 to 176(-40 to+80) -40 to 176(-40 to+80) -40 to 176(-4Ot°+80) at. - �.� Relative Humidity 76NH 0-100 condensing 0-100 condensing -- - 0-100 condensing 50 Acoustic Noise Emission Level Maximum Operating Altitude without Derating elm 0(2 6560(2 0(2 P 9 9 rr+. _ 6560 6560(2000) 6560(2000) Mechanical Specifications — 0 - _ Enclosure rating NEMA4X NEAM4X3 NEMA4X Each inverter is set on specific grid codes which can be selected in the field Cooli"g Natural convection NaturalConvection Natural Convection Single phase output Dimensions(HxW 611 in(mm) 33.8x12.8x8.7(859x325x222)-S Version Weight (bag) <47.3(213)-S version <47.3(21.3)-S version <473(21.3)-S version Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System Wall bracket waR:(2eaxt Wall bracket different directions Conduit Connections"a Trade size O:(2ee side, Trade 1-1/4 :(2eex1/21 and Trade1-l/4 :(2eexidefrod (tea x 1-1/413 places side,front, (tea x 1-1/4;3 places side,front, (tea x 1-1/4;3 places side,front Wide input range rear) rear) DC Switch Rating(Per Con -_-- ----AN 25/600 25/600 -.__. High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting 25/600 Safety ,,:�_, . Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level t9 Y 9 Y P 9 P ___--„ _._- Transfomterless(Floating Array) Transformerless(_ T� the entire input voltage and output power range Safety and EMC Standard UL 1741,CSA-0222 N.107.1-01 UL 1741,CSA C222N.107141 :UL1741,CSA-C222N.107.1-01_ Safety Approval --- -I - - -L - -- r LA. Outdoor enclosure for unrestricted use under any environmental conditions Warranty Integrated DC disconnect switch in compliance with international Standards(-S Version) Extended Warranty 1..__» . 1.._-.. - ___ ... ,o I to r RS-485 communication interface(for connection to laptop or datalogger) Available Models 15�2D 15620 15120 Compatible with PVI RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PYE3.0Otlif>•US pyF36q/IpUS With DC Switch sad Box f ., ____.....__- — _-- PIM2d11WK — 30-0tITfYS-US PV1-3.6C1RD S US IV143-01.11DYS IIS aN4tteYssa/ed6leAtapsrliwems.r - .. _ ._ 1 RORA UNO "4i8barliM+taaraaiat wasp and wish su6ldeatOCpewraxeRele "wMnowl adrMeW.mocswain&w w a.aw AURORA UNO 3 ` r CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention: Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rdr}f empstorav Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix l or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment for Use With Distributed Energy Resources(January 28,2010) DQD 507 Rev.2009-09-01 Page:t TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions ■ DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA s STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-P„�x(Wp) 240 245 250 255 260 rk ,d- Power Output Tolerance-P,,,,.(%) 0/+3 0/+3 0/+3 0/+3 01+3 r, g Maximum Power Voltage-V,.r(V) 29.7 30.2 30.3 30.5 30.7 Maximum Power Current-Imn.(A) 8.10 8.13 8.27 8.36 847 \TSM - PA05 .18 p911 Me -�o Open Circuit Voltage-Vac(V) 37.3 37.5 37.6 37.7 37.9 •KT"a•'c101E Short Circuit Current-Ic A 8.62 8.68 8.85 8.92 9.00 Module Efficiency (%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE STC:Irradiance 1000 W/m',Cell Temperature 25°C.Air Mass AMI.S according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-I. S 3 I 3 ELECTRICAL DATA:a:NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Poor(Wp) 174 178 181 184 188 Maximum Power Voltage-V„w(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINEoODULE 6.ouarom+avx,,,nle Maximum Power Current-Ivvr(A) 6.55 6.64 6.70 6.77 6.86 A A - WITH TRINAMOUNT FRAME 12°'"1M41F - Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 ` '".1 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 - 812mm I 180 I NOCT:irradiance at 800 w/m',Ambient'emperature 20°C.wind Speed I m/s. ' 240-260W Back View POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA • Compatible with all major BOS components and system -1 11 I Solar cells Multicrystalline 156.156 mm(6 inches) designs Cell orientation 60 cells(6 x 10) • Module dimensions 1650 x 992 x 40 mm(64.95•39.05 x 1.57 inches) % Weight 18.6 kg(41.0Ibs) '' MAXIMUM EFFICIENCY Lill Glass High transparency solar glass 3.2 mm(0.13 inches) Bocksheet White •� ,y , ., One of the industry's most trusted modules Frame Black Anodized Aluminium Alloy with Trinamount Groove RI•,?% • Over 2 GW sold across all major global markets +307 • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated 0 Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10.'0 -- 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9.m 1000W/m' B ____ Connector Original MC4 --7e 800W/m0 __ __ Highly reliable due to stringent quality control d 5.6 600W/m' As c leading global manufacturer • Over 30 in-house tests(UV,TC, HF,and many more) U 3W 400W/m' `- TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic - • In-house testing goes well beyong certification requirements products,we believe close 2.°G 200w/m' \ Nominal Operating Cell 45°C(*2°C) Operational Temperature -40-+85"C cooperation with our partners I. Al Temperature(NOCT) Maximum System 1000V DC(IECJ/ is critical to success. With local O.Oy 10 ac z0'° 30 a tl 40 Temperature Coefficient of Poor -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina is - Voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service to each customer in each market Temperature Coefficient of Isc 0.047%/°C and supplement our innovative. Certified to withstand challenging environmental reliable products with the backing conditions of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors )Please refer to product warranty for details m and other partners as the backbone of our shared success in CERTIFICATION r driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY m ('� 7 n PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty -- \ aM 'sp„ Modules per box:24 pieces Trina Solar Limited ■ A www.trinasolaccom mtp0% - Modules per 40'container:672 pieces F ISO �a (E ©. .w ennz 12 a Addition at. v aar r • 0 90% V CrVE from Trina Sara?S r111ea.h'Q/farlfy CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODuCT. c TrinasolarTrinasolar m 2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet ore subject to ,t l7 BO% change without notice.Smart Energy Together ye«s 5 10 I5 20 25 Smart Energy Together 0 coop,,' ■ Industry standard ■Trina Solar