Report --"- PWU ENGINEERING INC. Il f\ -1 )03-601G-1 Ph: (503) 810-8309 Email: Dwuenaineerina( comcast.net Field Memo Fix: Job #: MC13134 Hato- 17I'41111 Client: Fowler Home Design, Timberland Homes Proiect: Lot 4 Troy Park. Tiaard. OR Dear Steve, Dennis; At Dennis's request we visited the site today to observe the problem with the bearing support where the plumber had chipped out the concrete under the garage beam on the right middle side of the garage. Please see the attached framing plan done by others. Please note that the design of the beams and framing were done by Troy Fowler design and are outside the scope of our work. Our work previously was for the lateral shearwalls only. As discussed to provide a fix for the bearing a 4x4 post was installed on the garage side of the beam please see the attached photo. In addition to this fix we are recommending that the damaged concrete be chipped flat and then backfilled with 10.000psi min non-shrink arout. Please see the attached photograph for the fix. Secondly. there were some minor very small penetrations throuah some beams for electrical that do not appear to be an issue. Again, we did not size the beams and cannot comment on their adequacy as they were sized by others and are the responsibility of Fowler Desian. However. the penetrations are so small that they should not have an effect on the current beams, please see attached photos. Sincerely. ��FED PROFFs c� • 1 cc , 1 • A Ayr22.1. 31e31- 2 ��1 LfP Expires: 06130/2014 -7-1,-p-7 b.,c-raAid 4._C '74 --r•-oy "Pa a-, 1.--(d.,. C —I)7 el 19 �oaf /1/6-1 02013 —C- «VV.-- Version: 3.1 Designed on January 10,2014 VV r. Beams/Joists Analysis and Design wwpo.org ASD Method How to ---- ' Order Pro Developed by: Forum Engineers Enter Data Print Version Setup (: Beam or Girder C Joist or Rafter Member# Al Memberati Floor Roof Location : Main Floor Repetitive Use?I Nominal Size : ( 1 ) 4 x 10 Incised for PT? No Yes Species = Douglas Fir-Larch Flat Use: No Yes '"Dimension Lumber*` Grade= No.2 Moisture Content: <19% >19% Span(L)= 9 ft - 0 in Temperature(°F): X100 100-125 125-150 1 Tributary Width(B)= 1 ft - 0 in ...___._ 777 Unsupported Length(lu)= 1 ft - 0 in Set Duration Factors E with Cantilever Set Deflection Limits i- with Point Load(s) Reset Loads to Zero F with Sloped Load(s) (pressed-down buttons are selected) L . w .s I1111111111111111111111111111111111111111111111111111111111111111IIII1 111 LOADING Load Type • Max.Span = 9 ft - 2 in A Dead Load Uniform w(psf)= 183 111 R2 s.—/q:), y.,3— ci) / Q 3 5 1903 lb 1904 lb LrJAU. C90 G°Q •ca 3P µ Q '> (o8 Stress and/or Deflection Check D. OK A c t u a I A l l o w a b l e Ratio Floor Live Uniform w(psf)= 240 Max fv(psi)&V(lb) 73 1577 180 3885 41% + , -,C.2:::)," 3.3 6 r.yr0 / CD=1.00 1Qinen-P Y. C Z 5' /am Max fb(psi)&M(lb-ft) 1030 4283 1078 4485 95% Total Load Max.Defl.(in) -0.17 U639 L/240 0.45 38% Live Load Max.Defl.(in) -0.10 U1126 U360 0.30 32% Adjustment Factors 2500 for Fb for Fv for E 2000 ;0000 Wet Service CM= 1.00 1.00 1.00 so0 Temperature Ct= 1.00 1.00 1.00 -5oo Beam Stability Cr= 1.00 N/A N/A I -2503 Size CF= 1.20 N/A N/A Flat Use Cf„= 1.00 N/A N/A Shear Force,V(lb) Incising Ci= 1.00 1.00 1.00 Repetitive Member Cr= 1.00 N/A N/A 6000 - Buckling Stiffness CT= N/A N/A 1.06 4000 (C, for Emin only) Design Values in psi 2000 Fb Fv E Emin 0 Reference 900 180 1600000 580000 Adjusted 1078 180 1600000 580000 Bending Moment,M(1b-ft) ' Section Properties breadth(b)= 3.5 in depth(d)= 9.25 in . Area(A)= 32.4 in^2 Section Modulus(Sx)= 49.9 in^3 Moment of Inertial(lx)= 230.8 in^4 1 Total Load Deflection(in)