Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT 2 . COMMUNITY DEVELOPMENT Permit #: MEC2013 -00734 T E GARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 12/05/2013 Parcel: 2S 114AA00200 Jurisdiction: Tigard Site address: 16285 SW 85TH AVE 304 Project: Custom Machining Subdivision: 1993 -078 PARTITION PLAT Lot: 2 Project Description: Replacing (2) existing warehouse heaters. Contractor: W1LLAMETTE HVAC LLC Owner: WH SHIPMAN LIMITED 3075 SW 234TH AVE. #206 BY NORRIS & STEVENS INC HILLSBORO, OR 97123 621 SW MORRISON STE 800 PORTLAND, OR 97205 PHONE: 503 - 259 -3200 PHONE: FAX: 503 - 848 -2597 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 12/05/2013 $130.46 Class of Work: ALT Type of Const: Plan Review 12/05/2013 $32.62 Occupancy Grp: Occupancy Load: 12% State Surcharge - Mechanical 12/05/2013 $15.66 Stories: Info Process /Archiving - Sm $0.50 (up to 12/05/2013 $1.00 11x17) Project Valuation: $2,500.00 Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 2 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $179.74 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. ' Yo / y may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 4 411111111k )2 )/ej . r.\ 1.800.332.2344. �n y Issued By: i Permittee Signature: f Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLY Cl of Tigard Received City g e Date /By: f ' , IIPM Permit No.: j - • i _ 13125 SW Hall Blvd., Tigard, OR'' �3�' _w� i �`_' t c ) j Plan Review Other Permit: Phone: 503.718.2439 Fax: 503' t Date /By: T 1 G A RD Inspection Line: 503.639 Date Ready /By: luris • 61 See Page 2 for Internet: www.ligard or.gov D r (' 5 2 Notified /Method: 0 Supplemental Information tl TYPE OF of IOI � 3A COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Y A t,, •• 3 . " °� to ^ Mechanical permit fees* are based on the value of the work ❑ New construction ® Addition /aft$it %replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. Value: $ $2,500.00 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ I- and 2- family dwelling ® Commercial /industrial ❑ Accessory building For special information use checklist. ❑ Multi - family ❑ Master builder ❑ Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning Job site address: 16285 SW 85th Ave Tigard (requires site plan showing placement) 46.75 Furnace 100,000 BTU (ducts /vents) 46.75 City /State /ZIP: Tigard OR Furnace 100,000+ BTU (ducts /vents) 54.91 Suite /bldg. /apt. no.: 3 Project name: Custom Machining Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Subdivision: Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 Gas fireplace/insert Replace 2 existing warehouse heaters with new. 33.39 Flue veent ntfor or water ater heater or gas fireplace 23.32 Log lighter (gas) 23.32 Wood /pellet stove 33.39 Wood fireplace /insert 23.32 ❑ PROPERTY OWNER ❑ TENANT Chimney /liner /flue /vent 23.32 Other: 23.32 Name: Environmental exhaust and ventilation: Address: Range hood/other kitchen equipment 33.39 City /State /ZIP: Clothes dryer exhaust 33.39 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 23.32 CO APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 23.32 Other: 23.32 Business name: same as below Fuel piping: Contact name: $14.15 for first four; 54.03 for each additional Address: Furnace, etc. Gas heat pump City /State /ZIP: Wall /suspended/unit heater Phone: ( ) Fax: : ( ) Water heater Fireplace E -mail: Range CONTRACTOR Barbecue Business name: Willamette HVAC, LLC Clothes dryer (gas) Other: Address: 3075 SW 234 Ave Suite 206 MECHANICAL PERMIT FEES* City /State /"ZIP: Hillsboro, OR 97123 Subtotal Minimum permit fee ($90.00) Phone: (503) 259.3200 Fax: (503) 848.2597 Plan review (25% of permit fee) CCB lie.: 56951 State surcharge (12% of permit fee) r TOTAL PERMIT FEE (1 Authorized signature: � This permit application expires if a permit is not obtained within 180 g J ' days after it has been accepted as complete. Print name: michael malstrom Date: 11/26/13 * Fee methodology set by Tri- County Building Industry Service Board t: \Building \Permits \MEC- PermitApp.doc 03/07/12 440 -4617T (II/02 /COM/WEB) . ,)l 7 1.11111411 DEC 5 201 OPINE 6 -460.8 Cii'tii,''',' ;� ,a April, 2007 ,_,' "" �,,- , -�,�����'���I HAT SUBMITTAL DATA _ 0,4' day - - = °° anima) power vented gas -fired unit heaters � f Rt�l� /® DAWG Certified for Residential model HD and Commercial Use �//\��� 3 OUN LR t° ICE COPY A MOUNTING QQIRQ G BRACKET ADJUSTABLE POWER VENTER VENT PIPE CONNECTION LOUVERS ELECTRICAL 1.00 � CONNECTION I i,111 ., a • 1 GAS / I� �1,,,. ; A ; I CONNECTION ll OPENING �, �.1' ;_ :II � F i I C D OPENING H ACCESS J PANEL REAR VIEW Performance Dimensions (inches) Models HD30 HD45 HD60 HD75 HD100 HD125 Models HD30 HD45 HD60 HD75 HD100/125 Btu/Hr Input 30,000 45,000 60,000 75,000 100,000 125,000 A 26.8 26.8 26.8 26.8 35.5 Btu/Hr Output 24,000 36,000 48,000 60,000 80,000 100,000 B 12.2 12.2 18.0 18.0 20.5 Entering Airflow (CFM) 505 720 990 1,160 1,490 1,980 C 16.5 16.5 16.5 16.5 22.0 Outlet Velocity 523 749 653 769 565 747 D 14.9 14.9 14.9 14.9 22.5 Air Temp. Rise ( °F) 44 46 45 48 50 47 E 10.1 10.1 15.9 15.9 18.4 Mounting Height (Max ft.) 10 10 12 14 12 16 F 7.5 7.5 10.7 10.7 14.0 Heat Throw (ft.) 25 27 36 38 42 56 G 18.5 18.5 18.5 18.5 24.0 Horsepower 1/15 1/15 1/12 1/12 1/12 1/8 H 7.6 7.6 7.8 7.8 8.4 Motor RPM - 1,550 1,550 1,625 1,625 1,050 1,550 Gas Connection 1/2 1/2 1/2 1/2 1/2 Data Type S.P. S.P. P.S.C. P.S.C. S.P. P.S.C. I 34.5 34.5 34.5 34.5 43.0 Amps 2.4 2.4 1.2 1.2 2.7 2.2 J 22 22 25 25 31.0 Unit Total Amps 3.7 3.7 2.5 2.5 4.7 4.2 Fan Diameter 10 10 14 14 18.0 Vent Connector Size (in.) 3 3 3 3 4 4 Approx. Shipping Weight (lbs.) 55 60 80 85 125 Mounting Clearances 1" - angle, mounting brackets are slotted to accommodate joists Clearance To Recommended on 16" or 24" centerlines. Unit Side Combustible Materials Service Clearance I o 0 o c' 1°0 0 0 o el Top and Bottom 1" 1" ! 1 I I I I HD30 - 1 1 1 1 I I Access Side 18" 18" 0 0 0 0 00 0 0 0 0 0 0 N Non - Access Side 1" 1" 0 • of ' ei 66 U) F- C ) N N NN Rear 18" 18" Vent Connector 4" 4" I "o 0 0 0 =Too 0 0 0 0 0 0 0 "I 11 I I I I I I HD100/125 I I I I I 11 I O I IIn 0 N 0 11 Y l( N Y 0 U N O O M A U) n O) f') U) N ^ O1 N N N N N f") N) t') Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 11 115V 24V natural 30-125 - Utilizes a single -stage combination gas control with ignition control. Gas is lit with a direct spark igniter on call for heat. 21 115V 24V propane 30-125 Two-Stage, Direct Spark Ignition, 100% Shut -Off with Continuous Retry 12 115V 24V natural 75-125 - Utilizes a two-stage combination gas control with built -in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark 22 115V 24V propane 75 -125 igniter on call for heat. U Attachment id to roof joist SIDE VIEW 11" lag g bolt bolt and and I.5" unistrut typical ROOF JOIST 0. threaded rod HEATER 16GA. WIRE CITY OF TIGARD Approved [ " J Conditionally Approved [ ] See Letter to: Follow [ ] Attached [ ] Permit Number: Mr'yc 01 —00 Address: / . FS ‘Ti-ti J'S ' 41-/- . 7-e .3d`1 Ey: frr ate: 1,1/5//3 OFFICE COPY