Loading...
Correspondence October 9, 2013 RE: NEW BUILDING Project Information Building Permit: BUP2013-00225 Construction Type: 5-B Address: 7148 SW Gonzaga Occupancy Type: B/R2 Area: 11,309 Sq. Ft. Stories: 3 Name: The Adrienne Sprinkled: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2010 edition; 2010 Oregon Fire Code and NFPA 13. Please provide the following conditions prior to issuance of the permit. 1) Please show details of all supporting construction for floor/ceiling separating B occ from R2 occ. 2) Please provide details for all fire stopping such as can lights, exhaust fans and ducts, and tub penetrations in the rated assemblies. 3) Provide details of rated exit enclosure. 4) Show 42" height of balcony guardrails. 5) Provide accurate door schedule showing door rating and self closing doors. 6) Show details of termination of roof stairs. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson Senior Plans Examiner (503)718-2436 dann @ tgard-or.gov „ . •., 1,•■ •• • ) 02(DD -9011-1-d()Cd(1)5/ 01 —9P1243c) I r• id/5 CO - 9c)70 I- :( c)(Aty, zg-c,0(2)11 n )D.-D • lad r sg- • --"xeci(71-7111 _ S E A The Adrienne SCOTT!EDWARDS ARCHITECTURE LLP. Date: Oct 21'. 2013 To: The City of Tigard Building Department Attn: Dan Nelson From: Scott I Edwards Architecture Job: Permit# BUP2013-00225 Re: Plan review comments for `The Adrienne' 7148 SW Gonzaga St., Tigard OR Below, please find an itemized list of comments regarding the plan review of'The Adrienne' project at 7148 SW Gonzaga Street. All comments have been incorporated into a revised drawing set and indicated with a revision 1 symbol and cloud. 1) Please show details of all supporting construction for floor/ceiling separating B occ from R2 occ. • We have revised our drawings to indicate that the 2nd floor supporting structure (building assembly `FC2') to be spray applied fireproofed to achieve a 1-hr fire protection. See revised building assembly `FC2' on Sheet A9.1 2) Please provide details for all fire stopping such as can lights, exhaust fans and ducts, and tub penetrations in the rated assemblies. • Included in our revised set of drawings please find details 6, 9 and 12/A8.1 for typical fire protection details at electric box penetrations, recessed light fixtures and pipe penetrations through rated wall and floor assemblies. Please also find details 11 & 12/A8.3 for typical fire protection details at bathtub conditions at party walls. 2525 East Burnside Street I Portland,OR 97214 I p:(503)226-3617 I f:(503)226-3715 I www.seallp.com Sunnyside Library I Meeting Notes 1 10/23/2013 3) Provide details of rated exit enclosure. • New details have been added describing the continuity of the fire rating at units and the exit enclosure. Please see new details 4, 8/A5.1 as well as 4, 8, 12/A5.3. 4) Show 42"height of balcony guardrails. • Please see revised detail 1/A6.3 which indicates the typical balcony guardrail height of 42" 5) Provide accurate door schedule showing door rating and self- closing doors. • Door schedule has been updated to indicate required closers, fire/smoke gaskets at all 1-hr doors. All unit entry doors on 2nd and 3rd floor are indicated and now show a 1-hr fire rating. Unit interior doors are 6) Show details of termination of roof stairs. • Please see our revised roof plan which indicates that all mechanical units and equipment be greater than 10'-0" away from the edge of roof and therefore not be required to have guardrail protection per OMSC 2010 304.11. See revised roof plan on sheet A2.4 Please contact Brian Mares or myself with any additional questions or clarifications. Respectfully- Ken Dyreson, Scott I Edwards Architecture 2525 East Burnside Street I Portland,OR 97214 I p:(503)226-3617 i f:(503)226-3715 i www.seallp.com