Loading...
ROW2013-00105 111111 CITY OF TIGARD RIGHT OF WAY PERMIT I COMMUNITY DEVELOPMENT Permit#: ROW2013 00105 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 10/17/2013 Parcel: SEG1872 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Kleinfelder Project Description: Adjacent to SW Bonita Road from Milton Court to Interstate 5. Six total geotechnical soil borings between 25&40 deep.Two borings to be drilled on milton Court,four borings on Bonita Road. Borings are to characterize subsurface conditions as part of the perliminary design and planning wor for the Lake Oswego-Tigard Finished Water Pipeline project. Boring locations and traffic control plan are attached. Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX: Applicant: ANDREW GOODELL 9200 SW NIMBUS AVE, SUITE A BEAVERTON, OR 97008 PHONE: Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant p� Signature: i O •`?e on 1 , ( c ion ,/ •Issued By: #- /{r�; Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for ROW2013-00105 Type: Condition Name: Status: Severity: ROW 06-TRAF CTRL-ADVANCE WARNING Applied Notice Advance warning of imminent traffic disruption shall be provided to the general motoring public by placement of an advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. ROW 07-TRAF CTRL-PRIV PROP ACCESS Applied Notice Access to existing properties shall be-maintained at all times, including normal delivery service and mail service and if not, shall be cause for work stoppage until effective access is established. ROW 08-TRAF CTRL-DEVICES IN PLACE Applied Notice Traffic control devices, flagpersons,etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. ROW 09-TRAF/NOISE CTRL-WORK HRS Applied Notice No work will be permitted during the hours of darkness, nor between 9:00 p.m.to 7:00 a.m. Monday through Friday, nor between 9:00 p.m. to 8:00 a.m. Saturday, nor between 9:00 p.m. to 9:00 a.m. Sunday. ROW 10-TRAF CTRL-MIN LANE WIDTH Applied Notice Minimum travel lane width shall be eleven(11)feet; pedestrian travel shall also be provided for. ROW 11-TRAF CTRL-CITY CAN MODIFY Applied Notice The City reserves the right to add to or modify traffic control requirements as may be necessary to effectively control traffic and to assure public safety. ROW 12-INSP 24 HR NOTICE REQUIRED Applied Notice The permit holder or his contractor shall notify the City's inspector Kenny Fisher at 503-816-6146 or email at kenny @tigard-or.gov, twenty-four(24)hours prior to commencing work, twenty-four(24)hours prior to any staged inspection, and after completing work covered by the permit. ROW 13-HAZARDS-CERT OF INS Applied Notice Maintenance of the work area and approach roads is the responsibility of the permit holder.The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards.A copy of the permit holders Certificate of Insurance shall be available at the work area. ROW 14-DEBRIS-MATERIALS Applied Notice The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit.The City may at any time order immediate cleanup and stoppage of work to accomplish cleanup. ROW 15-EROSION CTRL REQ Applied Notice Effective erosion control is required. Erosion control devices must be installed and maintained meeting D.E.Q. requirements. The City may at any time order corrective action and stoppage of work to accomplish effective erosion control. ROW 16-REPAIRS-LIKE MATERIALS REQ Applied Notice Property disturbed by construction activity shall be seeded with a standard grass mix; shrubs,flowers, barkdust, existing signs, pavement markings, mailboxes, etc., shall be reestablished, reinstalled or replaced,with like kind and material. ROW 17-DRAINAGE CONTROL REQ Applied Notice Effective drainage control is required. Drainage shall be controlled within the work site and shall be so routed that adjacent private property, public property and the receiving system is not adversely impacted.The City may, at any time,order corrective action and stoppage of work to accomplish effective drainage control. ROW 18-UTILITIES PRELOCATION REQ Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0010 through OAR 952-001-0080. Copies of the rules may be obtained from the Center by calling(503)232-1987. If you have questions about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holders expense. ROW 19-UTILITY LOCATIONAL CONFLICT Applied Notice Contractor must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the permit holders expense. Changes must be approved by the City in advance of work performance. Contractor shall coordinate the work with affected utility agencies. • • ROW 20-TRENCH-PATCH/SAFETY/LBILITY Applied Notice A temporary hard-surface patch (Cold mix A.C. or Hot mix A.C. base paving) shall be placed on trenches within roadways at the end of each day's work. No trench, on site or off site, shall be left at any time in an unsafe condition.The permit holder is responsible for and is liable for hazards or damage resulting from the work. ROW 21-REPAIRS REQ-INSPTR OPINION Applied Notice Work provided for under the permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, in the City Inspectors opinion, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the permit holders expense. ROW 22-AS-BUILT/ENGR CERTIF REQ Applied Notice At the end of each year, or an a mutually agreeable yearly date, any entity making changes to its facilities in the public right-of-way shall submit complete"as-built"drawings showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineers certification of installation compliance(form attached). ROW 23-DAILY INSP REPORTS REQ Applied Notice The permit holders Engineer/Inspector shall submit daily inspection reports,on a weekly basis,to the City's Inspector. (see Developer-Engineer Agreement note#5). ROW 24-TESTS/REPTS TO VALIDT CLMS Applied Notice The City's Inspector may, at their discretion, require provision of tests and or reports from the permit holder, permit holder's engineer or contractor to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the permit holder's expense. ROW 25-RELEASE-WAIVER REQ Applied Notice The permit holder shall provide a copy of a properly executed Release&Waiver document to the City for each ownership disturbed by construction activity, as evidence of disturbance resolution and owner satisfaction. ROW 26-MONUMENT PROTECTION REQ Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holders expense. ROW 27-PROB SOLVING-RESPON PARTY Applied Notice The permit holder shall provide to the City Inspector, in writing,the names and 24-hour emergency telephone number of two (2)persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of an emergency. The permit holder shall notify the City Inspector, in writing, of any/all assignment changes. ROW 28-CONSTR SAFETY-RESPON PARTY Applied Notice The permit holder shall cause his contractor to provide to the City Inspector, in writing,the name and 24 hr emergency telephone number of a designated"Competent Person"responsible for construction safety as per OR-OSHA, Chap. 437, Div. 3 Construction, Subdivision P-Excavations.The contractor shall notify the City Inspector of any/all assignment changes. ROW 29-ESMT/RT OF ENTRY-RESPON Applied Notice It is the sole responsibility of the permit holder to provide for proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry, or properly executed easements,shall be provided to the City.The City shall in no way be construed to be liable for the permit holder's failure to obtain or provide for proof of right-of-entry or easements. ROW 01-CUSTOM CONDITION Applied Notice Additional traffic control requirements Submit a plan to keep the rail road right-of-way clear for trains and directing WB Bonita traffic to the curb lane before crossing 72nd. No obstruction of Bonita traffic 6:30-9:00 a.m. and 3:30-6:00 p.m. ROW 02-PERMIT&PLAN REQ ON SITE Applied Notice A copy of the permit and all attachments,and a copy of the approved construction plan and all amendments shall be available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's Standards and Specifications and to these General Conditions. Changes to any of the aforesaid must be approved by the City, in advance of work performance. ROW 03-TRAF CTRL-SPECIF(CITY) Applied Notice The City's standard specification for traffic control is"Manual on Uniform Traffic Control Devices for Streets and Highways", U.S. Dept. of Transportation, F.H.A., 1988 Ed. ROW 04-TRAF CTRL-CONTR RESPON FOR Applied Notice Traffic control shall be provided for by the contractor in accordance with the City's standard specification and, also, in accordance with a City (job specific)approved traffic control plan.A copy of the approved traffic control plan shall be available at the work area. ROW 05-TRAF CTRL-ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without having first obtained written approval from the City Engineer.The permit.holder is responsible for provision of timely notification of traffic flow disruptions to area wide Emergency Services(Tigard Police Dept.,Tualatin Fire&Rescue)and to Tri-Met and Tigard School District. 1111 City o f Tigard Application For Work In Right-Of-Way TIGARD ROW Permit A-\. Property Address/Location(s): SW Bonita Road-Milton Court to Interstate 5 FOR STAFF USE ONLY S IS(o5 / ISIS j 1611 1 1-12 Right-of-Way Case No.: 2-1)13 COI US *Applicant's Name:Kleinfelder Application Accepted: f By: Address:9200 SW Nimbus Avenue, Suite A Application Reviewed&•/6•/1 By;0 City/State;Beaverton, Oregon dip_97008 Application Fee Due: /Verge P ' Contact:Andrew Goodell nrl' Applicant Notified: O`l7 Phone:503 644 9447 f>aa. Receipt No.: Email:agoodell @kleinfelder.com REQUIRED SUBMITTAL Contractor's Name:Kleinfelder INFORMATION CCBtf Expiration: • Application form,completed and signed Address:9200 SW Nimbus Avenue, Suite A • Submit one(1)copy of scaled sketch of Beaverton, Oregon l 97008 the proposed work to be done City/State g 7.ih P 1? Phone:503 644 9447 Fax: • Submit one(1)copy of traffic control Email:agoodell @kleinfelder.com plan Professional Engineered Plans are required Plans By: Kleinfelder for: Address:9200 SW Nimbus Avenue,Suite A • Street Widening City/State:Beaverton, Oregon zip:97008 • Subdivision Infrastructure Phone:503 644 9447 Fax: • Main utility line extension F.,mail:agoodell @kleinfelder.com Rev.6/24/2013 t:curpin\masters\land use applications\row app.docs Description of work:(6)total geotechnical soil borings between 25 and 40 deep.(2)borings to be drilled on Milton Court.(4)borings on Bonita Road.Borings are to characterize subsurface conditions as part of the preliminary design and planning work for the Lake Oswego-Tigard Finished Water Pipeline project.Boring locations shown on attached map. Traffic control plan also attached.One of the borings will have a standpipe piezometer installed in the center turn lane of Bonita with a flush monument at the pavement surface. Estimated value of work(within the public right-of-way): $ Is work related to a LAND-USE DECISION? YES ❑ NO it If so, please specify(MLP,SDR,SUB,etc.)case# Is the work related to a BUILDING PERMIT? YES El NO El If so, please specify(BUILDING PERMIT)case#: AIWA Signature of Applicant/Permittee:c Date Print Name: ^'tart- :c,v t Title: ^.G" Gccxx :..iS T City of Tigard I 13125 SW Hall Blvd.,Tigard,OR 97223 503-718-2464 ( www.tigard-or.gov feiL -• ..iii, ,-,..•;P3/4 ..- ,...., ..,,,,,,04041: ,..,,,--,„,zwif,z,t-u.1.4. --,,mi.f43-4-k...L.F.-vir..1. .. ,,,,„;.--!ii -1,044,,,,,ft4V4470.4.._.• '',.i.ktqw:'-.470-;: ' -.''''''.;"'.*5-P''41.47410,2t43:::':.t."''''‘,,;,,v1'..1.4%‘:4 ..,--nak4ic;4441t*-iii=-71,WPI ';' :,-wi-Rii.t.';'=1*41,1.,,il7.'11:':'..111-22-„''''-i, . s,:..70';tV:747p*,..-'t"-1€7'7,.. "'''':'r:,.-,) ".,.,- -'°,!,...AL-4-Z.,1-ii!Iit*,,iiiir.f7.*-1.='!'=-,..t:r1 ',..;k4g2' Tic*2-- -„ ,.;- KVA 1 .i.:itj::A,,,=gblt,titpo DI• . i:i1J'‘ .:.:-..;,; .YZA:'''.-;:"--,ktiti-!'::41.;0;"2:'!...-77' ,-,"'"-'3.''..1.':-',,..;-.4.41:-1:4: ac..';..+t°,ifkilin, .. .,..............4 s.,.. ' •.--ih,-..,,,-.',nfl.'41.=t-',,-,.i''.,:',,,,,"'27----.,„ :i"Fg: \''':;0'!!lq.t,,t-57"k't.'"'%- tC"J;i:',144, 1‘16.-Lt1/1441441,t61*4-- "-'.,"■46":`,`,Mji;;11:!,tibP 47 1""“'":::..„-",',':,` "' 7444'4;'-''g -'.- ::-.'',..:',3,;:„4"if,;%.*7•,:,4PP.,Li?zItIoNziei-,$\401.:' ..,.21:t.7.5-,.:- 24100.,N:\o'siittV`;414:,'",..N44.14141,,e'l ., ',: ,'..ttr7"77.,-7-::::"t.,',777,3'4:2 741' 1`47: 1''m i..---',.,. >':,-',,,,"'". ,,,,,,,,:r:,...,,,A7i7,.:-,:;:1,74%,,, ,,4:31 ii...kietki4k,I 2 -•Z;tl'i:1,4A:Air..,.,,,,',1i :ra;:,''.l.l4'';-.L* ir-4,,,,,t'A i; e II e;.(4.40.3\,„':7Steii-,,t1aNkit,lt klf 9 .;-':"ViAl;*2 ,_.'''..6',,,,,Ztl.7 4,,,'''-'-'';,..-,',t.:-,,..7,47,.7.,,;:i;: t,„111,', 17.31 ll4ailt7t;I' ,.a dirlT■i.i ilicAak'"---,, t7■R;IZX''6.6r'''j't AP-'-.'-n'i'MieV; e lIkAilt4 .:=':=:": 'Ir. ,'=t-Ilr ,,IN,,...,.,. ,;..,.... ,-....-,. -,-1.1%::,,V 0,44,w,';...vri ..,,A.-it' _ ,-,'y, ,,,,t,,,F;.,,z,,,„wras--4 •ix*, li'',.=,,1,,,...L.-.,-,,,.,,,t,...,.,imikf.r,A,41.4.■-„„..,.....,.. . -- . ,- Vc:en'"' ...;*;;:;;44...mit.lit!,% ,,,,j .,._ , 04,70,•:."04..N:,,,,,%%,,A,:,,4!.144f.ANNViN44,'„,,,q11047).b -41111t.T.,4 ,.:?:103i.AU-4744;,'P:-6?.;=!*1 Vi:lettki4Titi:41!ii ,, . „.,..,. ...,,•=4".?:4T.git.,-;.A4...:-. 3,.,,,t,-\:4.1X-,-,-.A0',N.4.1, T f.*:s.:,,r--1.lino ,ri --7,,,,,,,,c-efai3-1"krf„'--','-.-at"..... . .--z.---4. ..'1'.•fm-...,..;.,....,4:*-,4m--.-=-Nlifi,17,-..,;,....4= ..-`-.2164i 2:''-;-',--,:',.;13;74..,r4n. ''44,f1-4,11:T.Atiltk,,,;.:::-.-?- ,-,,,,,,,,i,,,, „-,,,,,,,,,,,,,4„...* ,,,,,,,,.;‘, 12,4.,,,,.„,,,,, , ,„.*,,,,U4,....71711,4',.f ,—,,,--7,,,,,,k AciiVviV,..;',..0f,tielv,,s, , ■wil%, '13:.•,.- V - „ -...r 1- •,. "rti4,10.1-at.N.-.1-aN, ‘..14:_.„-tt ,,,,,,,,,e,,',,,!(,4,1:42,,,N76,:r!. )• ',,,,„%,„liq4: il:r4iiTo45%,1,::117:7*., 4r7,4.7;.itt"„RI,A4,,?-' \ i (44.41/4-11.4:14 , 'fiCi4P;74‘ II,V''?''''''''‘'''-''''' 'r*---; r.:-.1. ."t''''' '''.10').7T=14'11ikri*47.11,41141;!---=4M F;1,ii.`,!:;;i''0,,7%.1";;4` '.'":‘.:''''',q?•=7..i., 'KL,,*0-344V,Attl:.4.,:,kli 4:=241-ff ,,ik,,,,,,,,,, ,... N1478'ilt. -2":7'-'; '' '' nk,p'tlif44--::";,:- -,5WF:ty.Xii,fg., :_, :,,:i.A.N, . 1.1 h?t,"',X4f :*S,',Iihrika.---:,w4i,f`, qii".;•1 It , q,,,,„ -11.--,-",';IIiiv if.-;'4.11PI,77,',;. s,',•,,'„J'kilitt.e;i:,-:-. • ,•.:„.,,,Iirt: , 1,Nitalv„„,,,,,,,„, sw„:„„„,73,445„r,,,,,t.;11iiiimott.9„,iuxi....00.,ii_„:,,:4„:44,1„,,i1„, iNik,, ■_s,p,"' .' -','-,a'a'T4 ill,a,'".'-4.,,,-,,..4 „Atille‘l''''.`"' ":4'.-'11-49:•;t'-4"Wo",..4,7 '',.7-,,,t,I..,e4141.4,::';1.-,;i4- ,. , ..t. i„.,...12 ,A tivki, ,ii, ,:.,N,,,‘,„:1_.: ',...).i1;■ ,..„.„„-„A n. ., i, v tArt4.7 411,Ni 1 5.4144404_14.*.t5tlY'.47;:- IiI110,i00,44YSI k''''': :"I4sfit.itql 44.tkV2.7M, I.k.'4,1.',.=..l',1 Z!F.,,,:',I'7"4 ' - 111 f Ill ;5 A Go°g 1000 1 400 --zfr.-..'A74.7.41,,,tk4*1141tr.::-.7. „-gty,i'd:.1024.:•''..14, '''' ''."4' '? it,AttiA.:V*q'-,'L' -• iti, ' 1 74F-P'6'i,''''.'. ',.74:ti‘*In..4'• -. feet, e earth ,,. me t e rs1 Stopping/Sight Distance Northwest Buffer Space Traffic Control c Speed(mph( Distance(ft) Spseed Spa gng(h)+� Portland (503)262-6500 Vancouver(360)604-5655 25 75 (Mph) A B I C Fax (503)262-0357 30 100' 100' 100' Toll Free (800)783-9733 30 100 (or less) 35 125 35-40 350' 350' 350_ 45-55 500' 500' 500' 40 150 45 180 50 210 Buffer Buffer 55 250 C% I I Merging tapers=L Shifting taper =1/2L A= Road Work Ahead x2 Lane B= Center Lane Closed Ahead x2 Width 10' 11' 12' 20mphl 70' 75' 80' 25mph 105' 115' 125' 30mph 150' 165' 180' 35mph 205' 225' 245' 40mph 270' 295' 320' 45mph 450' 495' 540' 50mph 500' 550' 600' Buffer 55mph 550' 605' 660' Shifting taper (see chart) O P, Y . ► B n l • • • •J. •-• A= Road Work Ahead x2 B= Reverse Curve Leff xl C= Center Lane Closed xl Owner Project lob Number) Klenfeld Prolecl i Name/Locaer tion SW Bonita Road Tigard OR Prime Contractor Tralim Control Contractor _Kleinfelder Northwest Traffic Control.inc. Conlocl namernumber E-mail Andrew(503)919-1 700 All signs and devices SHALL conform to the MUTCD/OTTCH Prepared by OF Cents 10/4017 WACerI#Exp.4130/2017 Nalthan Burris 03884 007445) Will adjust to field conditions. Plan NOT to scale. Nathan @NWTCI.com File date: 10/04/2013 ■ • Northwest Traffic Control c Portland (503)262-6500 Vancouver(360)604-5655 Fax (503)262-0357 Toll Free (800)783-9733 Stopping/Sight Distance Buffer Space Speed(mph) Distance((f) 25 75 30 100 I — 35 125 40 150 45 180 50 210 Cone taper optional for 55 250 work in one location for less than 15 minutes. 1- • • • C> \S/ L�l Flagging Taper 50'-100'max Device spacing 20' max, A= Road Work Ahead x2 B= Be Prepared to Stop x2 C= Flogger Ahead x2 Posted Sign +/ Speed Spacing(ft) (Mph) A B C 30 100' 100' 100' (or less) 35-40 350' 350' 350' 45-55 500' 500' 500' Owner Project/Job Number Kleinfelder Protect Nome/Locotlon LSW Milton Court Tigard,OR Prime Contractor Traffic Control Conbactori _Klelntelder No_rtbwest lroltic Control inc,I Contact name/number E-mail Andrew(503)919-1700 All signs and devices SHALL conform to the MUTCD/OTTCH Preparedby OPCerIN 10/2013 WA Cede Expo/JO/2017 Will adjust to field conditions. ENalthan_Burris 03884 007445 Plan NOT to scale. I Nathan @NWTCI,com File date: 10/04/2013