Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
V CITY OF TIGARD MASTER PERMIT III a COMMUNITY DEVELOPMENT Permit#: MST2013 00229 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/05/2013 Parcel: 2S109AC03600 Jurisdiction: Tigard Site address: 14687 SW ANGUS PL Subdivision: WILSON RIDGE Lot: 10 Project: Purcell Project Description: Installation of solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $0.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: PURCELL,MIKE P&JACKIE A ELEMENTAL ENERGY LLC Required Items and Reports(Conditions) 14687 SW ANGUS PL 14500 SW 92ND AVE TIGARD,OR 97224 TIGARD,OR 97224 PHONE: 503-679-4032 PHONE: 503-967-5786 FAX: Total Fees: $318.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Cod a d all y er applicable All work will be do = eccordanc= ..th approved plans. This permit will expire if work is not started within 180 days of issue•ce, o if 0 is sus.-nd 4 more the 180 day . ATTENTION: Orego law .=quires you to follow the rules adopted by the Oregon Utility Notification Cente, •Jose rules arjrainn.i.. in OAR 95 -001-0010 through OAR 952-I• -0r•0. Ail may obtain a copy of the rules or direct questions to OUNC by calling 503'32.19:' • :05 Is ued By: •� =� =��%� _i�,• Permittee Signature: .... ��' ' ` Call 503.639.4175 by 7:00 a.m.for the next available inspection•ate., This permit card shall be kept in a conspicuous place on the Job site until com•letio. • the project. Approved plans are required on the Job site at the time of each In-•ect+ . Building Permit Application Residential / / ( J;, a,i /11-- ��,-- I��� FOR OFFICE USE ONLY I. City of Tigard ll�� Received ry Date/By: lD a /3 , / Permit No.:Ml rrl w/ --,z) Q q 13125 SW Hall Blvd.,Tigard,OR 97 r 2013 Plan Review OY.dJ CiCJ'� Phone: 503.718.2439 Fax: 503.598. 9 d Date/By: ICYp Other Permit: TIGARD Inspection Line: 503.639.4175 ---vi �, Date ReadyBy: Juan: El See Page 2 for Internet: www.tigard-or.gov if. ,,--- �Y 1(LA' I hW- ij . • M-thud:// � Supplemental Information TYPE OF WORK / RE ED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit a s*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Z Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ ❑Accessory building CI Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: /4; Job site address:14687 SW Angus PI New dwelling area: square feet City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Purcell Residence PV Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST 1 Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. i 7kW Prescriptive Roof Mounted PV System Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Mike&Jackie Purcell Type of construction: Address:14687 SW Angus PI City/State/ZIP:Tigard,OR 97224 Occupancy groups: Existing: Phone:(503)679-4032 Fax:( ) yp ® APPLICANT New: ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name:Elemental Energy LLC (Please refer to fee schedule) ti Contact name:John Grieser Structural plan review fee(or deposit): 1 Address: 14500 SW 92nd Ave FLS plan review fee(if applicable): City/State/ZIP:Tigard,OR 97224 Total fees due upon application: Phone:(503)967-5786 Fax: :( ) Amount received: t E-mail:john @elementalenergy.net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:Elemental Energy LLC Submit two(2)sets of roof plan with connection details Address: 14500 SW 92"d Ave and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP:Tigard,OR 97224 Permit Fee(includes plan review and administrative fees): $180.00 Phone:(503)967-5786 Fax/ ) CCB lit.:195141 ithkre State surcharge(12%of permit fee): 60�"AIN Total fee due upon application: $201.60 Authorized signature: / / , / This permit application expires if a permit is obtained within 180 days after it has been accepted as comp Print name:John Gries I Date: 10/28/2013 I *Fee methodology set by Tri-County Building Industry J Service Board. 1:\Building\Pemiits\B UP-RESPcrmitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) Electrical Permit Application �_�,� ��, ;. ,,if U,' FOR OFFICE USE ONLY li City of Tigard Received �e� r, '��n 40 y g Date/B : /D , Permit No.: d 13125 SW Hall Blvd.,Tigard,OR 97223 OCT 2 0 2013 Plan Review 0, ' Phone: 503.718.2439 Fax: 503.598.1960 DateB Other Permit: TIGARD Inspection Line: 503.639.4175 ( Date Ready/By: Luris: ® See Page 2 for Internet: www.tigard-or.gov C�Y��u" ���:(„��� Notified/Methal: Supplemental Information ^^r r.;,v^a� rr•.:,ar. TYPE OF WORK':- PLAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked below): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑ Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived system. ❑Addition of new motor load of ❑"A","E","I-2","I-3", Job no.: Job site address: 14687 SW Angus PI I OOHP or more. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP:Tigard,OR 97224 ❑Health-care facilities. ❑Supply voltage for more than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name:Purcell Residence PV ❑Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total I • New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq.ft.or less 168.54 4 Ea.add'I 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.0.) Limited energy,multi-family 75.00 2 7kW Roof Mounted Presctive PV Install residential(with above sq.ft.) Renewable Energy ® See Page 2 Services or feeders installation,alteration,and/or relocation ® PROPERTY OWNER ❑ TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Name:Mike&Jackie Purcell 401 amps to 600 amps 200.34 2 Address: 14687 SW Angus P1 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP:Tigard,OR 97224 Temporary services or feeders installation,alteration,and/or Phone:(503)679-4032 Fax:( ) relocation 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel ® APPLICANT I ❑ CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name:Elemental Energy LLC each branch circuit B.Fee for branch circuits without Contact name:John Grieser service or feeder fee,first 56.18 2 branch circuit Address: 14500 SW 92nd Ave Each add]branch circuit 7.42 2 City/State/ZIP:Tigard,OR 97224 Miscellaneous(service or feeder not included) Each manufactured or modular 67.84 2 Phone:(503)967-5786 Fax: :( ) dwelling,service and/or feeder Reconnect only 67.84 2 E-mail:john @elementalenergy.net Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:Advantage Electric LLC Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address:814 SE 46th Ave Each additional inspection over allowable in any of the above City/State/ZIP:Portland,OR Additional inspection(1 hr min) 66.25/hr Investigation(I hr min) 66.25/hr Phone:(503)2355854 Fax:( ) di�/N Industrial plant(I hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 190742 Electrical Lic.:.C-622 Suprv.Lic.: 4619S specifically listed(%hr min) Suprv. Electrician signature,required: _ d! Imo �_ ELECTRICAL PERMIT FEES Subtotal: Print name: Dan Broughton b e: 10/28/F Plan review(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Date: days after it has been accepted as complete. * Number of inspections allowed per permit. 1:\ItuildinglPermits\i'l C_PermiiApp_tit.R_IiRti.doc Re,1)5/21/2013 440-46151'(I Il05/CUM/WI'.11 PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-NTS TABLE OF CONTENTS 1. 7 KW DC,6.02 KW AC SOLAR PHOTOVOLTAIC SYSTEM 2. 3 STORY COMPOSITE SHINGLE ROOF AT 24°PITCH. ARRAY PITCH MAGNETIC TRUE -° xw PAGE 3. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT RUN PLACEMENT ORIENTATION ORIENTATION •-. r� O C I C� 3 O4. Q. 1 # DESCRIPTION WITH CUSTOMER. AR-01 24° 204° 180° - {•�•. . v v `J PV-01 SITE PLAN&MECHANICAL 4. CONTACT:MIKE PURCELL ..- 5. DESIGN CRITERIA: q . F 5.1. SYSTEM WEIGHT:3LBSisc1FT. TOTAL PV ARRAY AREA 504 FT2 PV-02 RACKING LAYOUT • 5.2. EFFECTIVE WIND SPEED: 90 MPH 3-SEC GUST. `°°' "" LARGEST PV SECTION: 38 FT PV-04 SINGLE LINE DIAGRAM 5.3. WIND EXPOSURE CATEGORY:B 1::..• r ROOF SLOPE: 24° 5.4. SNOWLOAD: 25 PSF + ° " • 5.5. OCCUPANCY CATEGORY: II ROOF AREA MEASURED IN PLAN VIEW: 2472FT2 w_•, PV ARRAY/ROOF AREA: 20.39 % ELECTRICAL EQUIPMENT LOCATIONS: NTS SITE PLAN -SCALE= 0.012141 PROPERTY LAYOUT i 1j/11 OCT 2 8 2013 s.. ATTACHMENTS SHALL BE SPACED NC GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS • - •^:`;• '•` PROPERTY LOCATED WITHIN 3 FEET OF A ROOF SETBACKS EDGE, HIP, SAVE OR `MIDGE. '' . '.•.•` r)SISC 305./!.3's) :v: (N) PV PRODUCTION METER *�.� (EXTERIOR WALL) 4 CITY` �JF ,,<1GARD Approved JF`�/w��j� [V3/ (E) SERVICE Conditionally Approved [ ] ENTRANCE& UTILITY METER See Letter t0:Follow Permit Nu . [ ] #---- PPPIIIIIT (INTERIOR WALL) Attached• '� � r V _[_ I (E) MAIN PANEL �r (INTERIOR WALL) Address: ��� U:L a71 By: pp. Date: • �' l I Approved plans (N)SOLADECK (E) ROOF VENT shall be on job site. COMBINER/DISCONNECT 0 0 0 0 0 0 0 TYP 0 OFFICE COPY Y/7 FIRE SETBACKS FIRE SETBACKS (3'TYP) (N)ARRAY AR-01 (3'TYP) • 1 1 En ELEMENTAL ENERGY ENGINEER: JOHN G ELEMENTAL ENERGY PURCELL SITE PLAN & REV A DRAFTER: JOHN G. OR CCB#: 195141 14687 SW ANGUS PL,TIGARD, OR 97224 MECHANICAL PV 01 10/27/2013 • • RACKING LAYOUT BUILDING EAST FACING ELEVATION: . \ ...„,;,, ,`. 8"MAX HEIGHT OF MODULES %04 STAND OFF ` 44'-0" — 3'-7" —/ 26' --o —o —43 —8 -e- -e- o o e- o c o--o o—o o --O O —G- I —o —0 — —0- — -e-- — o c o —o o — o I —0 o — -e 0 0 0 0 0 0 - -0 —e I --o 0 -e- -e- — e- c 0— —o o — -e I —o o — o — ---e- — -e- — 0-- 0— —0 0 — -e 0 2Z-0" .-0 - 0 — —e- — -0 e— C 0 --0— 0 - 0 I —o —o -- -e — -e- -e- e- 0— o— —o — -e -e —0 \--- -e- — -e-- e- c o —o --o MOUNTING DETAIL: I �(N)STANDOFF (E)2"X8" @ 4'TYP #2 DOUGLAS FIR PREFABRICATED I PV MODULE TRUSS P @ 24 OC TYP SNAPNRACK FLASHED L-FOOT KIT STEP 3: SECURE L-FOOT (MIN)5/16" 18 x 4"SS HLS TO STANDOFF BASE TO l' 5/16"SS SPLIT I (MIN 2.5"THREADED SHANK MOUNTING RAILS LOCK WASHER I EMBEDMENT INTO STRUCTURAL SECURE FLASHING AND ROOFING MEMBER) STEP 2:SLIP FLASHING OVER SNAPNRACK L-FOOT I L-FOOT BASE 2'_6" 5/16"x 3/4"FLAT WASHER STEP 1: BOLT L-FOOT BASE SNAPNRACK CHANNEL NUT I 5/16"-18 x 3/4"SS HCS TO ROOF WITH LAG BOLT SNAPNRACK STANDARD RAIL \ I i —' 5/16"-18 SS FLAT HEX NUT s �\ 5/16"SS SPLIT LOCK WASHER SNAPNRACK L-FOOT BASE �\ �� - ROOF DECKING 40000. SEAL PENETRATION AND UNDER BASE WITH 1- RAINBUSTER(OR O/ EQUIVALENT)SEALANT (E)ROOF 4 • DECKING SNAPNRACK n COMPOSITION 6 so,\0,I' FLASHING co tP`ElED IN (E)RAFTER SNAPNRACK RACKING SYSTEM SERIES 100: L-FOOT MOUNTING DETAIL Ex) ELEMENTAL ENERGY ENGINEER: JOHN G ELEMENTAL ENERGY PURCELL RACKING REV: A DRAFTER: JOHN G. OR CCB#: 195141 14687 SW ANGUS PL, TIGARD, OR 97224 LAYOUT PV 02 10/27/2013 LINE DIAGRAM: 120/240 VAC t SINGLE PHASE SERVICE VOLTAGE DROP CALCS PORTLAND GENERAL ELECTRIC DC MODULES TO COMBINER; © METER#: VOLTAGE DROP FOR 240 VAC,4 WIRE, 1.0M PORTRAIT • ENGAGE CABLES AND M215S, END FED(FROM SPEC. UTILITY SHEET) IS 0.29% • GRID j EXISTING COMBINER TO MAIN PANEL; 100ft. MAX: C200A MAIN %VD= (2 x 100 x 11.25 x1.26/1000)/240= 1.18% q BREAKER WALL PENETRATION ENPHASE: M215 TOTAL V.D. =0.29%+ 1.18= 1.47% EXISTING SOME PAIRS MICROINVERTER %--- 200A MAIN (N)SOLADECK NOT SHOWN PV MODULES PANEL ETO COMBINER & _ FOR CLARITY _ PV /� FACILITY y PRODUCTION METER DISCONNECT s �, �-( 1 +CD 3 3 3 2 2 v O Q Q o� - �� o INVERTER OUTPUTS CONNECT ENPHASE ENGAGE CABLE LDK: 250D CONNECTED TO OUTPUT CABLE TO END TRUNK (28) MODULE/INVERTER PAIRS 40A PV BREAKER 250V METER SOCKET ENGAGE CABLE ENGAGE CABLE TERMINATION KIT (2)CIRCUITS OF(14) PAIRS EACH OPPOSITE SIDE OF 240V METER BUSBAR 200A, FORM 2S UTILITY TO LOAD SIDE PV TO LINE SIDE _ NOTES TO INSTALLER: CONDUIT SCHEDULE ETO PROJECT # CONDUIT CONDUCTOR NEUTRAL GROUND 1. UTILITY CONDUCTORS TO LOAD SIDE, BOTTOM 2. PV CONDUCTORS TO LINE SIDE,TOP 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 3. AC/DC VOLTAGE DROP MAXIMUM AT 2% RESPECTIVELY 2 3/4" EMT OR EQUIV. ENPHASE ENGAGE CABLE NONE (1)6 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 POINT OF INTERCONNECTION: MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS BACKFED BREAKER ON MAIN PANEL LDK: 250D 250 W SYSTEM SIZE 7 kW 1. ADD 40 AMP PV BREAKER TO MAIN PANEL 2. MAIN PANEL RATING:200 A OPEN CIRCUIT VOLTAGE 37.8 V SYSTEM OPEN CIRCUIT VOLTAGE 37.8 V 3. MAIN PANEL MAIN BREAKER RATING: 200 A OPEN CIRCUIT VOLTAGE: (690.7) 41.8 V SYSTEM OPERATING VOLTAGE(690.7) 41.78 V MAX POWER VOLTAGE 29.9 V MAX ALLOWABLE DC VOLTAGE 45 V SHORT CIRCUIT CURRENT 8.92 A SYSTEM OPERATING CURRENT 8.38 A ELECTRICAL NOTES: SHORT CIRCUIT CURRENT(690.8(A)(1)) 11.15 A SYSTEM SHORT CIRCUIT CURRENT 8.92 A 1. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2011 NEC. LABEL PLACEMENT:AC BREAKER 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2011 NEC. (INSIDE OR FRONT OF PANEL) 3. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 4. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 5. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 8.92 AMPS MODULE SHORT CIRCUIT CURRENT. 13.92 AMPS DERATED SHORT CIRCUIT CIRCUIT(690.8(a)&690.8(b)). • EXII) ELEMENTAL ENERGYIDRAFTER:ENGINEER: JOHN G ELEMENTAL ENERGY PURCELL SINGLE LINE REV: A JOHN G. OR CCB#: 195141 14687 SW ANGUS PL, TIGARD, OR 97224 DIAGRAM PV 04 10/27/2013 Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14687 SW ANGUS PL, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection 2013-11-07 (null) MST2013-00229 PASS - No C of O Violation Summary: Inspector Contractor A457-62-0 13— ao2Z1 • City of Tigard 1111 Building Division RECEIVED 13125 SW Hall Blvd,Tigard,OR 97223 Phone:503.718.2439 Fax:503.598.1960 TIGARD Inspection Line: 503.639.4175 OCT 2 8 2013 www.tigard-or.gov CITY OF TIGARD 1r DING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14687 SW Angus PI City: Tigard Zip: 97224 Owner's Name: Mike & Jackie Purcell Date: 10/28/13 Contractor's Name: Elemental Energy LLC CCB #: 195141 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard . Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? • structures other than " ", above qualifies for ❑ Yes the If Yes presc riptive path. ❑ No 1 IJBuilding/Forms/Photovoltaic-Checklist.docx Is the construction Type of material wood and does Yes yP the construction qualify If"Yes",qualifies for Construction as "conventional light 0 No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3)of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the t yp e of ❑ of wood shingle/shake one of the three types material roofing material g checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof If"Yes",qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 l:/B uilding/Forms/PhotoV oltaic-Checklist.docx Yes If"Yes", ualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for I I Yes the prescriptive path. No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for Yes the prescriptive path. j No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to - inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? n Yes the prescriptive path. No Is the roof decking of WSP min. 1/2"thickness, I Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/l 2"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:/Building/Fonns/PhotoVoltaic-Check Iist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and,as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: LDK Model Number: 250D Listing Agency: UL s 4 IJ Building¢/Fonns/Phaovoltaic-Checklist.docx