Permit q CITY OF TIGARD MASTER PERMIT
0 COMMUNITY DEVELOPMENT Permit#: MST2013-00194
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/09/2013
Parcel: 2S 101 DC05700
Jurisdiction: Tigard
Site address: 13495 SW 74TH AVE
Subdivision: PACIFIC RIDGE Lot: 9
Project: Waldon
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $0.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Fum>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: N Other Description:
Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
WALDRON,W WAYNE JR DYNAMIC POWER INNOVATION LLC Required Items and Reports(Conditions)
13495 SW 74TH AVE 236 SE BAKER STREET
TIGARD,OR 97223 MCMINNVILLE,OR 97128
PHONE: 503-684-9002 PHONE: 503-857-0416
FAX:
Total Fees: $328.88
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be d in actor.. .. with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
d . ATTENTION: Or=.•on law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
9 2-001-0010 through OAR•52-'•1-009. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
Is ued By: M% 11 / ' Permittee Signature: , /. ..—s./,„d_,i
Call 503.639.4175 by 7:00 a.m.for the next available inspection date. /
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the Job site at the time of each inspection.
" RECEIVED
Building Permit Application
Residential AUG 2 2 2013 FOR OFFICE USE ONLY
City of Tigard Received / 03/ Permit NeST.20/3 DO//y
g g CITY OF TIGARD DateB � -QSt�'
° 13125 SW Hall Blvd.,Tigard,OR 97223
Plan Review
Phone: 503.718.2439 Fax: 503.598.19 Other Permit:
`BUILDING DNISIO Date/B : �� 1' El Page 2 for
I'IGAItD Inspection Line: 503.639.4175 Date Reary.By: U g
Internet: www.tigard-or.gov Notified/Method: / /(� �'/e Supplemental Information
E,19-iL- - & •
TYPE OF WORK REQUIRED DATA:I-AND 2-FAMILY DWELLING
❑New construction ❑ Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replaccmcnt ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
® I-and 2-family dwelling ❑Commercial/industrial Valuation: $
❑Accessory building ❑ Multi-family Number of bedrooms:
❑Master builder ❑Other: Number of bathrooms: • i
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 13495 Sw 74th Ave New dwelling area: square feet
City/State/ZIP:Tigard,Oregon 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Waldon Solar Covered porch area: square feet
Cross street/directions to job site:SW Cherry Drive Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision:Pacific Ridge Lot no.:9 Permit fees*are based on the value of the work performed.
Tax map/parcel no.:2S101 DC05700 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
6.7kW Roof Mounted Solar Array Valuation: $
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name:Wayne Waldon Type of construction:
Address: 13495 SW 74th Ave
Occupancy groups:
City/State/ZIP:Tigard,Oregon 97223 Existing:
Phone:(503)684-9002 Fax:( ) New:
® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name:Dynamic Power Innovation Structural plan review fee(or deposit):
Contact name:Josh Kopczynski FLS plan review fee(if applicable):
Address:236 SE Baker Street
Total fees due upon application:
City/State/ZIP: McMinnville,Oregon 97128 Amount received:
Phone:(503)857-0416 Fax::( )
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail:dee @dpisolar.com
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Submit two(2)sets of roof plan with connection details
Business name: Dynamic Power Innovation and fire department access,along with the 2010 Oregon
Address:236 SE Baker Street Solar Installation Specialty Code checklist.
Permit Fee(includes plan review $180.00
City/State/ZIP:McMinnville,Oregon 97128 and administrative fees):
Phone:(503)857-0416 Fax:( ) ' State surcharge(12%of permit fee): $21.60
CCB lic.: 185494 A//OS Total fee due upon application: $201.60 ✓/
r • This permit application expires if a permit is not obtained
Authorized signature: '4_,�(� , , within 180 days after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry
Print name:Josh Kopczynski Date: • .. Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-461 3T(1 1/02/COM/W EB)
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
City of Tigard Received Permit No.:
lipq a 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By:
C . Phone: 503.718.2439 Fax: 503.598.1960 Associated permits:
24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical
TIGARD
Internet: www.tigard-or.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW 1 Yes I No 1 N/A
1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑
• 3 Verification of approved plat/lot. ❑ ❑ ❑
4 Fire district approval required. Name of district: ❑ ❑ ❑
5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑
6 Sewer permit. ❑ ❑ ❑
7 Water district approval. ❑ ❑ ❑
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑
9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ ❑ ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
I I Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ ❑
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-11.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator; lot area;building coverage area;percentage of coverage; impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑
over 10 feet long and/or any beam/joist carrying a non-uniform load. _
20 Manufactured floor/roof truss design details. ❑ ❑ ❑
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑
architect licensed in Ore!on and shall be shown to be applicable to the •ro'ect under review.
JURISDICTIONAL SPECIFICS I
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ ❑
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑
27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
l:\Building\Permits\BU P-RESPermitApp.doc 02/24/2011 440-461 3T(11/02/COM/W EB)
0
RECEIVED
Electrical Permit Application FOR circler t v1:ONI.l.
City of Tigard AUG 22 2013 PartitNo.: i/ T?.o/3-x/9 4
• 13175 SW Hall Blvd.,Tigard,OR 9Aq., OF Ti al) plan Review
Other Permit
ti Phone 503.718.2439 Fax 5035 DateB .
,_,G A,:D Inspection Line: 503.639.4175 BUILDING DN ISION Date Ready/By. � PI See Page 2 for
Internet: www.tigard-or.gov Notified/Method: Supplemental information
TYPE OF WORK PLAN REVIEW
❑New construction ®Addition/alteration/replacement Please check all that apply(submit sets of plans wlttetos checked below):
❑Service or feeder 400 amps or more ❑Balding over three stories.
❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 130 volts or ❑Floating buildings.
less to ground,or exceeds 14,000 ❑Commercial-use agricultural
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for an other installations buildings.
❑Multi-family ❑Master builder ❑Other: ❑Fun pump. ❑Installation of 150 KVA or
❑Emergency system. larger separately derived system.
- ,JOB SITE INFORMATION AND LOCATION 0 Mdilion of new motor load of 0"A","E","1-2","1-3",
100HP or mom. OacapancY•
Job no.:3S41343-4762 Job site address:13495 SW 74th Avenue Reereatinnal vehicle
❑Six or more residential units. ❑ parks.
❑Health-care frenies. ❑Supply voltage for more than
City/State/ZIP: Tigard,OR 97223 ❑Hazardous locations. 600 volts nominal
Suite/bldgJapt no.: I Project name:Weldon Solar ❑Service or feeder 600 amps or more.
FEE SCHEDULE
Cross street/directions to job site:SW Cherry Dove Description I Qtr. I Fa. I Total 1 •
New residential single-or multi-family dwelling unit
Includes attached garage.
Subdivision: Pacific Ridge Lot no.:9 1,000 sq.ft or less 168.54 4
Ea add'1500 sq.R or portion 33.92 1
Taxmap/parcel no.: 2S101DC05700 Limited energy,residential
75.00 2
DESCRIPTION OF WORK (with above sq.ti.)
. Limited energy,multi-family 75.00 2
8.7 kw roof mounted solar array residential(with above so.ft)
Renewable Energy el See Page 2 .
Services or feeders installation,alteration,and/or relocation
®:PROPERTY OWNER I . - ❑ TENANT 200 amps or less 100.70 2
201 amps to 400 amps 133.56 2
Name: Wayne Weldon 401 amps to 600 amps 200.34 2
Address: 13495 SW 74th Avenue 601 amps to 1,000 amps 301.04 2
Over 1,000 amps or volts 552.26 2
City/State/ZIP: Tigard,OR 97223 Temporary services or feeders installation,alteration,and/or
Phone:(503)684-9002 I Fax:( ) relocation
200 amps or less 5936 1
Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2
Owner signature: Date: Breath draft—new,aleration,or extension,per panel _
' .❑ APPLICANT I ® CONTACT PERSON A.Fee for branch circuits with
above service or feeder fee, 7.42 2
Business name: Cherry City Electric each branch circuit
B.Fee for brands circuits without
Contact name: Stephanie Woodward service or feeder fen,fust 56.18 2
branch circuit
Address: 8100 NE St Johns Road,#13-101 Each add9 branch circuit 7.42 2
Miscellaneous(service or feeder not included)
City/State/ZIP: Vancouver,WA 98665 Each manufactured cared or modular
Phone:(360)571-4411 I (360) 571-4410 dwelling,service and/or feeder 67.84 2
Fax: Reconnect only 67.84 2
E-mail: soodward@chenycityelectric.com Pump or irrigation circle 67.84 2
.' . CONTRACTOR Sign or outline lighting 67.84 2
Business name: Cherry City Electric Signal circuit(s)or limited-energy See
panel,alteration,or extension. Page 2 2
Address: 8100 NE St Johns Road,#D-101 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
City/State/ZIP:Vancouver,WA 98665 Investigation(1 hr min) 66.25/hr
Phone:(360)571-4411 I Fax:( 360)571-4410 Industrial plant(I br min) 7818/hr
Inspections for which no fee is 90.00/
0:33 Lie.: 91668 I Electrical Lie.:37-620C .1 Suprv.Lie:5719S specifically listed('hr min)
ELECTRICAL.PERMIT MEE
Suprv.Electrician signature,required: Subtotal:
Print name: Trace Thompson Date:6/25/13 Plan review(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: TOTAL PERMIT FEE
Print name: Dale:
This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
• Number of inspections allowed per permit
l SauddingTermas1EI.C_PomitApp_ELR ERndoe Rev 05/21/2013 410-4615T(11/O5/COMtw13a
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY:' :1 FEE SCHEDULE
Fee for all residential systems combined ... $75.00 Description I Qty. I Fee 1 Total 1 . _
Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva X 133.56 133.56 2
n Audio and Stereo Systems*
15.01 to 25 kva 200.34 2
111 Burglar Alarm Wind generation systems in excess of 25 kva:
25.01 to 50 kva 301.04 2
❑ Garage Door Opener* 50.01 to 100 kva 552.26 2
>100 kva(fee in accordance with 552.26 2
OAR 918-309-0040)
n Heating, Ventilation and Air Conditioning
System* Solar generation systems in excess of 25 kva: •
Each additional kva over 25 7.42 3
n Vacuum Systems* >100 kva—no additional charge 0.0 3
nEach additional inspection over allowable in any of the above:
Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed('h hr min)
COMMERCIAL WORK ONLY: -j ELECTRICAL PERMIT FEES
Fee for each commercial system $75.00 Subtotal:
(SEE OAR 918-309-0000) Plan review,if required(25%of permit fee):
State surcharge(12%of permit fee):
Check Type of Work Involved: TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
❑ Audio and Stereo,Systems days after it has been accepted as complete.
Number of inspections allowed per permit.
Ti Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
Ti HVAC
Ti Instrumentation
Ti Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
Ti Protective Signaling
Ti Other
Total number of commercial systems:
*No licenses are required. Licenses are required
for all other installations
I'Building\Permits\ELC_PermitApp_ELR_ERE doc Rev 05/212013
•
ys;20/3 y
RECEIVED
Cty of Building i Tigard D
ivision
• AUG 2 2 2013
- 13125 SW Hall Blvd,Tigard, OR 97223 CITYOFTIGARD
Phone: 503.718.2439 Fax: 503.598.1960 BUILDINGDNISION
T I GARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 13495 SW 74th Ave
City: Tigard Zip: 97223
Owner's Name: Wayne Waldon Date: 06/21/2013
Contractor's Name: Dynamic Power Innovation CCB #: 185494
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® No OSSC or ORSC for
design requirements.
Is the wind exposure ® Yes If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
® Yes the prescriptive path.
above
❑ No
1
I:/Building/Fortes/PhotoVoltaic-Checklist.docx
Is the construction
Type of material wood and does ® Yes If"Yes", qualifies for
the construction qualify the path.
Construction as "conventional light 111 p rescri prescriptive p
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. 111 Yes "Yes", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof No
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
I:/Building/Forms/PhotoVoltaic-Checkl ist.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑
No the prescriptive path.
115 lbs for 60 inch
spacing or less?
111 Yes "Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal anels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less qualifies for the
inches
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. ''/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the • If"Yes", qualifies for
solar modules module to the roof L Yes the prescriptive path.
surface. ❑ No
3
I:/Build ing/Fomis/PhotoVoltaic-Checkl ist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SolarWorld
Model Number: 240 Poly
Listing Agency: UL
4
(:/Building/Forms/PhotoVoltaic-Checklist.docx