Loading...
Correspondence 0001" M C5I.2_0 1 e/ Job No.: CEN-090 Harper Date: 02/04/2013 � p ;. Houf Peterson To: Dave Cady, Pulte Group Righellis Inc. ENGINEERS•PLANNERS LANDSCAPE ARCNITECTS•SURVEYORS From: Steven J Entenman P.E., S.E. -- - - - —• -- Project/Subject: Summer Creek Townhomes—Building 5, Lot 17&21 ❑ Fax- Number: ; Number of pages (If you did not receive the correct number of pages,please call 503-221-1131) ® E-mail ❑ Mail ❑ Hand Deliver ❑ Interoffice Dave, Per our phone conversation with you, it is our understanding that the second level type"9° holdowns at the front of the building were not installed as specified in detail 11 on sheet S7.0. Instead of wrapping the holdown straps around the beam as originally detailed, the bottom of the Simpson MST60 straps were aligned with the bottom face of the beam, and then secured to the front face of the beam and the holdown posts above. We have reviewed this existing condition, and determined that the reduced strap capacity is adequate to resist the code required uplift. We therefore take no exceptions to this existing condition. If you have any questions please do not hesitate to contact our office. Sincerely, Stttucru44( HARPER HOUF PETERSON RIGHELLIS INC. cA PRO/r �t.NGtNE4.4, Qy J ,2.320 J OREGON Steven J Entenman P.E., S.E. '‘ `?2y 15.x# #Q- Structural Manager N J. ENICI EXPIRESI 12-31-2013 205 SE Spokane Street Suite 200 Portland,OR 97202 PHONE 503.221.1131 FAX 503.221.1171 www.hhpr.com