Permit q CITY OF TIGARD BUILDING PERMIT lig 2 - COMMUNITY DEVELOPMENT Permit #: BUP2013 -00195 T I Q ARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/31/2013 Parcel: 2S113AB00500 Jurisdiction: TIGARD Site address: 16083 SW UPPER BOONES FERRY RD 310 Project: Sterling Bank Subdivision: FANNO CREEK ACRE TRACTS Lot: PT 37 Project Description: TI - Corporate office space build -out Contractor: BARTEL CONTRACTING INC Owner: G &S FC LLC PO BOX 160 16083 SW UPPER BOONES FERRY RD, GLADSTONE, OR 97027 STE TIGARD, OR 97224 PHONE: 503 - 650 -4084 PHONE: FAX: 503 -650 -4104 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIB DC Provision Review, COM TI - Ping 07/31/2013 $70.00 Occupancy Grp: B Occupancy Load: 49 DC Provision Review, COM TI - LRP 07/31/2013 $10.00 Dwelling Units: 0 Permit Fee - Additions, Alterations, 07/31/2013 $718.43 Demolition Stories: 3 Height: 0 ft 12% State Surcharge - Building 07/31 /2013 $86.21 Bedrooms: 0 Bathrooms: 0 Plan Review 07/31/2013 $466.98 Value: $48,595 Plan Review - Fire Life Safety 07/31/2013 $287.37 Info Process /Archiving - Lg $2.00 (over 07/31/2013 $12.00 11x17) Floor Areas: COT Address Fee 07/31/2013 $50.00 Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,700.99 Required: Required Items and Reports (Conditions) Fire Sprinkler: Yes Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended f'. more the 180 days. ATT , • I: • - • .11 law requires you to follow the rules adopted by the Oregon Utility Notification enter. Those les are forth in OAR 952 -001 4 01 0 through OAR • -00 : • T0. You may obtain a copy of the rules or direct questions to OUNC by calling 503.2 f 19: or 1.800 3;/.2344. Issue By: / I , - f / f Permittee Signature: • =aa aI ` �/ Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept In a conspicuous place on the job stte until completion of the project. Approved plans are required on the Job site at the time of each inspection. Building Permit Application Commercial RECEIV FOR OFFICE USE ONLY 11 City of Tigard Date /B 7 �b Permit No.: : C.� t i ,, 13-00/ ,, s ard, OR 97223 q 13125 SW Hall Blvd., Tig JUL 3 0 2013 e Plan Review ,AIF,_ Phone: 503.718.2439 Fax: 503.598.19 Date /B : r Other Permit: T I GA RD Inspection Line: 503.639.4175 ulTY OFTIGARD Date Ready /By: luris la See Page 2 for • Internet: www.tigard - or.gov BUILDING DIVISION! Notified/Method: Supplemental Information TYPE OF WORK REQUIRED DATA: I- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition /alteration/replacement ❑ Other: equipment. materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 111 I- and 2- family dwelling ® Commercial /industrial Valuation: $ ❑ Accessory building 1=1 Multi-family Number of bedrooms: I=1 Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 16083 SW Upper Boones Ferry Road New dwelling area: square feet City /State /ZIP: 97224 Garage /carport area: square feet Suite/bldg. /apt. no.: B/310 Project name: Sterling Bank TI Covered porch area: square feet Cross street/directions to job site: SW Upper Boones Ferry and Fanno Creek PL Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: W248495 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Corporate office space tenant improvement. This application for Valuation: $$48,595.00 Acoustical ceiling, metal stud framing, drywall, openings, core drill, rough Existing building area: 4032 square feet carpentry, roof patch, and fireproofing. New building area: 4032 square feet ® PROPERTY OWNER ❑ TENANT Number of stories: l ot3 Name: Norris, Beggs, & Simspon ATTN: Monique Clouser Type of construction: Tenant Improvem Address: 121 SW Morrison, Suite 200 Occupancy groups: City /State /ZIP: Portland, OR 97204 Existing: B & S -1 Phone: (503)684 -6000 Fax: (503)624 -0636 New: B & S -1 ❑ APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Bartel Contracting, Inc Structural plan review fee (or deposit): Contact name: Steve Sprawkins FLS plan review fee (if applicable): Address: PO Box 160 / 135 E Hereford St City /State /ZIP: Gladstone, OR 97027 Total fees due upon application: Phone: (503) 819 -9623 Fax: : (503) 650-4104 Amount received: E -mail: steve@bartelcontracting.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof -iop mounted PhotoVoltaic Solar Panel System. Business name: Bartel Contracting, Inc Submit two (2) sets of roof plan with connection details and tire department access. along with the 2010 Oregon Address: PO Box 160 / 135 E Hereford St Solar Installation Specialty Code checklist. City /State /ZIP: Gladstone, OR 97027 Pennit fee (includes plan review $180.00 and administrative fees): Phone: (503) 650 -4084 Fax: (503) 650 -4104 State surcharge (12% of permit fee): $21.60 CCB lie.: 79970 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Michael James Date: 7/24/2013 * Fee methodology set by Tri- County Building Industry Service Board. I: \Building \Permits \BUP -COM PermitApp.doc 02/24/2011 440- 4613T(I I /02 /COM /WEB) Building Division Development Code Provision Review TIGARD Commercial Projects - No Associated Land Use Case Building Permit No: o90/-00/7c 1:,ICExpedited Review Project Name: t 2 1.t OE!) &ADS Site Address: lie& g 3 6 (.t. ✓-' ,zero Suite /Bldg #: . Plans Routed: Original Plan Submittal Date: 7 /3/ // 5 Routed By: - 1 s` Revision Submittal Date: Routed By: 2n Revision Submittal Date: Routed By: To the Applicant: ➢ If the proposed use is not permitted within the zone, please contact the Building Division to cancel the permit application. Building Permit Technicians (503) 718 -2439. D. If a land use is required and for all other questions, please contact the staff person listed above the Planning Review section. Staff: please check items along left only if approved. 1� Planning Review (contact JtA d ; T4 at (503) 718 -fit 551 or 3 Iota; 7z. @ti - or. Proposal: ( vi 4 r i,v, w+ t.t.h ntt.✓ vFRLe. f .S ( Alec 144.5 pf� I, b c.La �aca..,'f... hie i.� bLc u $ ).c.J 0 ('i tt Zoning 17 Permitted Use Yes e No ❑ Land Use Required: Yes ❑ No Notes: LAY Approved ❑ Not Approved ❑ DCPR Not Required — No DCPR Fees Due Date Routed to Building: I: \C URPLN\Masters \Development Code Provision Review\DCPR_COM_NoLandUse.doc Rev. 01/16/13 Building Division Over- The - Counter (OTC) Building Permit T Gn Rb Check List Project Description: APPLICATION SPECIFIC INFORMATION GENERAL INFORMATION Class of Work *: kr Occupancy Group: Type of Construction: 2� Type of Use * *: CCM. Occupancy Load: Oregon Specialty Code: 7 ) SPECIFICS Number of Stories: '3 Building Height: Mixed Use: Number of Dw Units: Number of Bathrooms: Number of Bedrooms: BUILDING SQ FT - SCHOOL CET OTHER SQUARE FOOTAGES Story Square Footage: Accessory Structure: Covered Porch: Basement: Garage: Deck: Total Square Footage: Carport: Mezzanine: • SETBACKS Sideyard Setback — Left Sideyard Setback — Front Sideyard Setback — Right Sideyard Setback — Back CONSTRUCTION Exterior Walls: Openings Protected: Firewall Separation: N: S: N: S: Occupancy Separation: E: W: E: W: Access. Parking Spaces: REQUIRED ITEMS Fire Sprinklers: � Fire Alarms: Smoke Detectors: Sprinkler Type: Alarm Type: Protected Corridors: Standpipe Required: Pull Stations Required: _ Parapet: Hazard Group: Battery Calcs Provided: Density: Cut Sheets Provided: Design Area: K Factor: Total Project Valuation: $ ) .00 FEES DUE $ Q.CZ DC Prov Rvw, COM TI — Ping $ ((ACC) DCProvRvw,COMTI —LRP DC Provision Review Fee for COM TI,(effective 7/1/2013) $ pk--7- Permit Fee — Add, Alt, Demo Project Valuation Planning LRP $ J 12% State Surcharge • Up to $4,999 $0.00 $0.00 $ -IIIM "j Plan Review, Structural $5,000 - $74,999 $70.00 $10.00 $ , Plan Review, Fire Life Safety $75,000 - $149,999 $174.00 $26.00 $ J Z, O. Info Proc /Arch, Lg (over 11x17 $2.00) $150,000 and over $278.00 $41.00 $ Info Proc /Arch, Sm (up to 11x17 $0.50) $ Metro Construction Excise Tax $ School Construction Excise Tax $ Hourly Rate Fee $ Hourly Rate State Surcharge $ Misc. Admin Fee $ Other: $ Other: Building Staff: Date /Time: $ f 0, TOTAL FE DUE *TYPE OF USE: COM = commercial; CMS = commercial manufa red structure. **CLASS OF WORK ACS = accessory; ADD = addition; ADU = acces welling unit; ALT = . on; DEM = demo; NEW = new; OTR = other (use for fences, decks, retaining walls, signs, awnings or canopies). I: \Building \ Forms \OTC - BUP.docx 07/01/2013