Loading...
Specifications Carrier SUBMITTAL Project Bridgeport Distribution Date Thursday, March 07, 2013 CITY OF TIGARD Approved .gl Ni {--[ ✓i Conditionally Approved [ ] See Letter to: FoI low [ ] Attached Permit N s bey •• F' - `v■1 Addre•s: By: .Silts Date: Ira Approved plans shall be on job site. OFFICE COPY . RECEIVES CLIMATE CONTROL MAR 7 2013 16500 SW 72" Ave Portland OR 97224 CITY OF TiGARD HEATING a. AIR CONDmONIN6 BUILDING DIVISION 508A53 41122 —FAR: 503.968.1224 Bridgeport Distribution 16520 SW 72nd Ave Tigard, OR 97224 Overview lir IUNIT TO BE REPLACED k: •, -t-. . - ti; : / ice .� ,, „ ..f."., ,,* y. c' T_t r . � � _ "1 h; )1 � _ 1 I.• }�" _, _ • !' � • � � '—� �{ T � ' a ir t _ . y. y � S r er z , . , i 1 ri rj r � � .n r te, ;C � �a fi / • ) .Y ll ,1 *',1# ' I • ,. t• mo t' C/ ,f - -M1 - I 's• } ' - ' I J • , , r� s k 7 tr WI-, n . t - 4 , e ; i d ,. 1 A,. m 1 1 1 ,1 , r a S. •, 1, F .1.et' ;- S- 41.3 r _Jai. tit sta �I,: L _ _4 . • . 1 e ,! /- / . � � 1 ROOF ACCESS DOOR USE "BLUE KEY" SYSTEM DESIGN INSTALLATION -- SERVICE MAINTENANCE Page 1011 CLIMATE CONTROL 16500 SW 72a° Ave Portland OR 97224 -- HEATING a AIR CONDONING 503.453.4822 — FAX: 503.968.7224 Bridgeport Distribution 16520 SW 72 Ave Tigard, OR 97224 .. Map N • SW Kenton Or C m , I ■ . "-, 's .: 7e• k, l 6 4 SW Asnfol , i i p• ‘ 4, 7f, N Asteurc SI 11 . v: ( 1 I i ; Haring Ave 1 : ° \ co ) I l 54,1 -‘ ,."‘' kC : :\\1:'' S 'llii. . r: 15‘4: ; . 5 ' 2.7F, ;., lz ( ( 4.... , I ■ z ;7: . Se...itte St F (' A` Commun oral i , ity a s Ch t'' SW e-ood st . SW Alder SI ., ) ;If } ,; Washolgton CI 514,04 ., 0-1 71 - A/ * /----' / -5. ,. 4 S -- ., I i E , .9 : r) r,, i ). ,...,,,_ , —S. / •- ( '--•-•_..." • A ......--- - ---,_ • I i 0 • 727-------- .. '-' / / W , - : - 2 IX ._ • V. ' • f 1 i . ...1: '-I- i Lockwood • g s, aL cl-' 1 • PrOducte. 13 4.7. , , w CA ' • li > g /; i (41S° a5 a / '`' 1 P ' ' II r., .. * ' 6 ( , 3' . . I c ol Dr i 1 . ' ( k • ,i.6 / Jean f;TI Jean Rd co ii '‘i • 5 ., ' ' Bridgekil 1 .1 SP/ Village ei 4" `11,/ P- / N., g SYSTEM DESIGN INSTALLATION —SERVICE--- MAINTENANCE Page 1 of 1 S ' �j 1 7 ff( 4j ` I ®��t� MICR -HOLD for C arr i er n I Part Number: � � tit 48/50TC A/B04- A/B07,A/D08, A09,A/D12,D14,D16; FORM NO. 4250 =8P DATE: 2/12 50TCQ A04-A07,D08 -014; 48 /50HC A04- A07,D08 -D14; SOHCQ A04-A07,1308-D12; 48 /50TF,TM,HJ 004-014; 48150HE 003 -006; 0406 -0100 SUBMITTED TO Cityoingard 50TFQ 004 -014; 5OHJQ 008 -009 Units COMPANY: Climate Control DRAWN BY JOB NAME: Lincare EQUIPMENT NOTES: FEATURES; • Manufactured from 16 ga galvinized steel • Package includes: • (4) Hold -Down brackets • (48) s10 x 1/2" tek screws (12) per bracket • Some units may require additional Hold- Downs. 1110" • Use of this bracket provides a secure connection of the O rooftop unit to the curb, but does not result in a calcu- lated curb. 1" O • When attaching the brackets, confirm there will be no 0 interference with anything on the unit base rail. 4.129" .941" O O O O 2.757" 6 THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION • 3035 N. SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN. 46226 • 1-800.662 -4822 ••• MICROMETL WEST • 905 SOUTHERN WAY • SPARKS, NV 89431 • 1-800-8844682 Table Of Contents Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM Unit 1 3 Unit Report 4 Certified Drawing 5 Performance Summary 7 Packaged Rooftop Builder 1.34 Page 2 of 9 Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM Unit 1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.34 Page 3 of 9 Unit Report For Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM Unit Parameters Dimensions (ft. in.) & Weight (lb.)''" Unit Model 48TCDA06A2A6 -0A0A0 Unit Length 6' 2.375" Unit Size 06 (5 Tons) Unit Width 3' 8" Volts- Phase - Hertz 460 -3 -60 Unit Height 2' 9.375" Heating Type Gas ••• Total Operating Weight 579 lb Duct Cfg• Vertical Supply / Vertical Return Low Heat ••• Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size 1/2 Condensate Drain Line Size 3/4 Return Air Filter Type Throwaway Return Air Filter Quantity' 2 Return Air Filter Size 16 x 25 x 2 Unit Configuration Medium Static Option Al /Cu - Al /Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA06A2A6 -0A0A0 Rooftop Unit 1 Packaged Rooftop Builder 1.34 Page 4 of 9 Certified Drawing for Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM NOTES: ��yyIU UNITED r.0, e0[ u05 r� 000.111 I1 1A[ PIOP11+l a ❑ nlu 00300101100 sue Ies1M a n[a6 OIg1105 TO OPCNRAII 1. DIMENSIONS ARE IN INCHES DIMENSIONS UNIT U A '�.Y -r-r TECNxaaIES s +A.cos[, n e 1[ 000(03130 3000 000 111.1 [t <a0(0 (30 rw7 rx[ pp� ql fWerl rUiL IA[i P[IIOA.IM[L OA IN I I ARE IN MILLIMETERS. ' "WE II�� CAAAIEN lui+ cO 1 01 .1[L 001 A[ P1 030(01 D 01 u[[0 nrxout [IAxI [A u[[vrAU[ d CO2711321. I8TC -A0e 33 7/8 IB 5/8 A0r0u+10A•1111711111 CO31Ar. 2. S CENTER OF GRAVITY 18411 ( *T21 I E I8TC -105 18 J77 CONNECTION SIZES 3. y DIRECTION OF AIR FLOW 48TCA06 33 JIB t/ 8 A 1 3 /8' (351 DIA FIELD POWER SUPPLY HOLE 18411 (7171/1 B 2' 1501 DIA POWER SUPPLY KNOCKOUT 48TC'A01 1, 3/e 11 1/8 110511 (7771 C 1 311' 1511 DIA GAUGE ACCESS PLUG 11 -3/8 D 1/8' 1221 DIA FIELD CONTROL WIRING HOLE n 18481 E 3 /I'-II NPT CONDENSATE DRAIN I 1 /2' -I4 APT GAS CONNECTION ' • —7 G 2 1/2 ' 1611 DIA POWER SUPPLY KNOCK-OUT 7 : + 8187 EIOP710NAL 1H000 16 FILTER ACCESS ' (1061 1700E -LESS) PANEL co p , I iNAUTNC -B ASC CHART CONDENSER THESE NOTES REQUIRED FOR USE ACCE 55 COIL CAB iNPNp001A01, DO7A01 • • PANEL -- _ - THREADED WIRE A[0'D NOR[ INDOOR COIL ^ - CONDUIT SIZE USE SIZES INAL.1 MO. ACCESS PANEL N I /2' ACC. 7/8' 122.21 1I1I1 � 1 � 1 /l/�/ \ 25.5/8 10 -7 /8 M I /1' 24V 7/8' (22.21 t� I " " ""'� 1 RETURN _~ • [2771 R N Y 111 1001,0031 POWER 1 ( /B' 128.11 01•N .��1:]$I 14 1111 "\ ®/ AIR 21• 10051 1 /2' FPl GAS 1 3/76' 13D. 01 111171 � _�� 2 -5/8 \ \� "'_ �,• F INGS F BASEPAH' FACTORY OPTION. BACK 1671 �; j� FITTINGS FOR ONLY 0,8, 8 Z ARE PROVIDED TIP E ALT. - SELECT EITHER 3 //' OR 1!1' CURB ° N CONDENSATE 17 -1 // ( ' FOR POWER, DEPENDING ON WIRE 512E WIDTH 1 • A DRAIN OPENING (1511 1 1 J • Y IN BASEPAN SUPPLY 26 -1 /r 29 3(8 SUPPPLY 0011 PROVIDES 3/1' FP1 1NRU CURB 115918 Z AIR (613] 17171 FLANGE 6 FITTING. 71 113121 1 SEC THRU THC 4 ; 1571 6 -1/1 Id111 (36 \--1-.......,4 � i S j BASE CHART . • 25 �� 1 AI /8 •••-- 3.3/8 ~ IJOTI 1851 / FLUF !6361 . 11001 HOOD - 18 -1/2 -.N., N TOP (4101 4.5/8 11181 101/2 12651 1351d E L[C7A ICAL �_ 137] E = I DISCONNECT - _, LOCATION - -- __ CONDENSER — — • W II CONTROL ANC ACCESS BLOWER I COIL — !!h: ACCESS PANEL ACCESS CONDENSATE ILTER .G = _ DRAIN 3 I 15 OPTIONAL 16381 lir , �. I 1/2 OPTIONAL 16 RITORN OUTSIDE Ilk FACTORY INSTALLED FACL 11 -3 /8 1127] 1 AIR AIR COXVE — — I ISCONNEED ANDLC 12891 SUPPLY AIR 1 OUTLET gggg _ i DISCONNECT / 21.1 /1 � = = N 1 1 -68 6 ' __ = m I (539] El (1601 I} 6 -1 /8 ��� ■�� 3-3/1 HANDLE I - 8.3/8 6 -5/8 1 1951 16 -3/4 116118 12131 11681 11711 (152] (11871 11 -3/8 .., 26 -3/4 (18881 (681 BAROMETRIC 31 -I/4 RELIEF 17931 FLOW 4 LEFT FRONT AIRPLY RETURN RIGHT AIR 003(1 0011 31112011013 48TC 04 -07 SINGLE ZONE ELECTRICAL 222 1 OF 11 -24 -08 09 -29-08 COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.34 Page 5 of 9 Certified Drawing for Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM UNITES O.O. 001 COCA TRp COMMIT IS TOE PRORIpT OF CORM C@VWATIOR 9N1RI6610R M lab[ ORAgR6I OR OOCORIII6 TECHROLOGICS loan[. n RO 11 O[l1Y[I[O UAOR iN[ [IIRU1 Cg01f10R iNAf 1N[ pp tf RD CM5111UT[ FAR1 TRA CQ RR ARC[ N C G STD. UNIT CORNER CORNER CORNER CORNER CApp1Ep 11[=1 CO1TIn1 nu wr R[ Olules[OOR O9I0 nTRWI Ce1n Ac6nlac[ d CplAai. UNI7 WEIGHT HEIGHT fAl WEIGHT 191 WEIGHT IC/ WEIGHT (D) HEIGHT CORV0uTI0R'6 olnu CORSIn. LBS. KG. LBS. KG._ LBS. KG. LBS. KG. LBS. NG. I I 2 481C•601 483 219 111 50 125 57 131 59 116 53 39 19911 23 15811 16 3/8 14161 681C-A05 537 211 124 56 139 63 145 68 129 59 39 19911 23 15841 17 11321 181C•806 569 258 131 _59 117 67 151 70 ' 137 ' 62 39 19911 23 15941 17 I/1 1138) 48TC -901 652 296 150 68 169 76 176 80 157 11 39 19911 23 15811 20 1/8 15111 CORNER A CORNER B 9 . — . - - • 0 0 14 ■ CORNER D I CORNER C 1, .. I TOP { } K ...... • iii z t::00 , ; i' i': : 00 FRONT SKIT Oaf SUMMERS 48TC 04 -01 SINGLE ZONE ELECTRICAL REV 20F2 11 -24 -08 09 -29 -08 COOLING WITH GAS HEAT 48TM500993 5 Packaged Rooftop Builder 1.34 Page 6 of 9 • Performance Summary For Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM Part Number:48TCDA06A2A6 -0A0A0 ARI SEER 13.00 Base Unit Dimensions Unit Length 74.4 in Unit Width 44.0 in Unit Height 33.4 in Operating Weight Base Unit Weight. 569 lb Medium Static Option 10 lb Total Operating Weight 579 lb Unit Unit Voltage- Phase - Hertz 460 -3 -60 Air Discharge Vertical Fan Drive Type* Belt Actual Airflow 1750 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB 67.0 F Entering Air Enthalpy 31.44 BTU /lb Evaporator Leaving Air DB• 56.4 F Evaporator Leaving Air WB 56.0 F Evaporator Leaving Air Enthalpy 23.75 BTU /lb Gross Cooling Capacity 60.54 MBH Gross Sensible Capacity 44.53 MBH Compressor Power Input 4.41 kW Coil Bypass Factor 0.045 Heating Performance Heating Airflow 1750 CFM Entering Air Temp 70.0 F Leaving Air Temp 101.2 F Gas Input Capacity 72.0 MBH Gas Heating Capacity 59.00 MBH Temperature Rise 31.2 F Supply Fan External Static Pressure 0.50 in wg Fan RPM• 1108 Fan Power 0.83 BHP NOTE Selected IFM RPM Range: 1035 - 1466 Electrical Data (Before July 30, 2012) Minimum Voltage 414 Maximum Voltage* 506 Compressor RLA• 7.7 Compressor LRA 52 Outdoor Fan Motor Qty 1 Outdoor Fan FLA (ea) 0 8 Indoor Fan Motor Type* MED Indoor Fan Motor FLA 2.6 Combustion Fan Motor FLA (ea) 0.24 Power Supply MCA 13 Power Supply MOCP (Fuse or HACR) 20 Packaged Rooftop Builder 1.34 Page 7 of 9 Performance Summary For Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM Min. Unit Disconnect FLA 13 Min. Unit Disconnect LRA• 69 Electrical Convenience Outlet None Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA 3.4 Power Supply MCA:.. 14 Power Supply MOCP• 20 Disconnect Size FLA 14 Disconnect Size LRA 82 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz 85.8 86.4 84.0 125 Hz 80.2 77.1 82.2 250 Hz 72.1 63.6 76.3 500 Hz 68.2 61.8 74.8 1000 Hz 64.9 61.2 72.5 • 2000 Hz 59.0 55.2 68.8 4000 Hz 60.6 50.6 65.6 8000 Hz 55.7 43.0 61.8 A- Weighted 71.7 67.2 78.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground 30.0 ft \ - ` I °' 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground 5.7 ft \ s \ f 4. Height of obstruction 0.0 ft q 0 " '' _ �- • \ U • 5. Horizontal distance from obstruction to receiver ft \ t 40 6. Horizontal distance from unit to obstruction 0.0 ft \ 0 \� Detailed Acoustics Information Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center (Lw), dB 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 87.2 Lw A- Weighted Sound Power Levels at Unit's Acoustic Center (LwA), dBA 57.8 66.1 67.7 71.6 72.5 70.0 66.6 60.7 77.7 LwA Sound Pressure Levels at Distance Specified above (Lp), dB 51.6 49.8 43.9 42.4 40.1 36.4 33.2 29.4 54.8 Lp A- Weighted Sound Pressure Levels at Distance Specified above (LpA), dBA 25.4 33.7 35.3 39.2 40.1 34.2 28.3 45.3 LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Packaged Rooftop Builder 1.34 Page 8 of 9 Performance Summary For Unit 1 Project: Bridgeport Distribution 03/07/2013 Prepared By: 10:49AM • Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 1s I MM 1�ORPM MIME 16 4 111. N 12 i �`�1�� 3. 00:. a 1D �`.mitoommor. 1 03 7COWIM c n 0 6 \ _ M II 1 I I E 04 � 200: i��. 0. �� . \BHP • 10 BH 02 ..„ 4 ..„ iimmomiri m ___...........mummign m 03 CE 09 12 15 18 21 24 21 Airilow(CFM- thousands) RPM= 1108 BHP =0.83 MaximumRPM =1466 MaximumHP =2.90 Note: Pleasecontactapplicationengineeringforse lectionsoutsidetheshadedlegion SC - System Curve RP -Rated Po int 1 , Packaged Rooftop Builder 1.34 Page 9 of 9