Specifications RECEIVED MAY 2 9 2009 Longstaff Condominiums CITY OF TIGARD Tigard, OR BUILDING DIVISION RCM Homes, Inc. FP 5 2 6 o - at.rn 39 9 Z 5 A v►o(a.v s 0+ 1 3 WI I - F p 5 2..c r o 9 - c v - c r o ya 838-0 M 2— c+ Se t 5 l v - ca y 1 3 16, 6k) r cr10 y Z 9. o ./t4 � 5 � r3 5 ff52ov9 o 2 p 52c.ra -c 9 � 1, r plo 5 2 07) - U-vTo y 5 9 I CPO " r r DMS Electric, Inc. 8504 SE Stark St. Portland, OR 97216 Ph (503) 209 9298 Fax (503) 252 6611 Fire Alarm Load Calculations Bldg 1, 2, 4 — 8 L❑NGSTAFF C ❑ND❑MINIUMS EOL (10) -NAC SECOND FLOOR EOL 2 (6) (1) FACP - NAC 1 -ZONE 1- FS - TS -EOL -ZONE 2- -' 120 VAC -IP - HSI-EOL FIRST FLOOR 1 RISER DIAGRAM - FIRE ALARM FA -0 LONGSTAFF CONDOMINIUMS LEGEND SYMBOL DESCRIPTION MANUFACTURER MODEL MOUNTING DATA MOUNTING HEIGHT IFACP I FIRE ALARM SILENT KNIGHT SK -2 FACTORY SUPPLIED 72 INCHES TO CONTROL PANEL ENCLOSURE TOP OF BOX HORN SYSTEM PA400 2 1/2' (64nn) ONE BETWEEN 80 AND 96 INCHES TO CENTER OR U SENSOR GANG BOX 6 INCHES BELOW CEILING TO CENTER OF BOX [5k HORN /STROBE SYSTEM SENSOR P2RK 2 1/2' (64nn) ONE GANG BOX BETWEEN FIRST AND SECOND FLOOR © SMOKE DETECTOR SYSTEM SENSOR 2WB 2 1/2' (64nn) ONE GANG BOX CEILING MOUNTED 6 INCHES FROM WALLS ® TAMPER SWITCH BY OTHERS IFSI FLOW SWITCH BY OTHERS a U N Q W Lt_ J al O SYSTEM a OPERATION ra n 0o WATER FLOW SWITCH X X TAMPER SWITCH X Global Project Values . t SILENT Project Name:I Longstaff Condo Standby Hours: 24 l i KNIGI I'!' Project ID:I Alarm Mins: 5 I Prepared By:JVIad Palrnk Derating Factor: 1 2 SK -4 Calculations Date:{5!20 /2009 Voltage Drop Warning Threshold % :I 10 1 Max NAC Current: 2.5 Amps Panel ID: SK -4 (3 amp version) J Model: SK -4 Fire Alarm Control Panel *Max Panel Current: 3.0 Amps Location: [Sprinkler Closet I Volts: 24 VDC * Maximum panel current can be 6.0 Amps with optional transformer Ckt.# Circuit Name p� Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL SK -4 SK -4 Main Control 1 0.085 0.175 SK -CAC4 SK -CAC4 Class A Mod. 0.000 0.000 SK -4XTM SK -4XTM Transmit. Mod. 0.000 0.000 SK -4XZM 1 SK -4XZM Relay Mod. 0.000 0.000 SK -4XLM SK -4XLM LED Module 0.000 0.000 IDC -1 Initiating Device Ckt 1 0.000 0.000 IDC -2 Initiating Device Ckt 2 0.000 0.000 IDC -3 Initiating Device Ckt 3 0.000 0.000 IDC -4 Initiating Device Ckt 4 0.000 0.000 NAC -1 Notification Appl Ckt 1 0.000 0.315 #18 Stranded 6.39 200 2.56 19.59 3.95% NAC -2 Notification Appl Ckt 2 0.000 0.250 #18 Stranded 6.39 200 2.56 19.76 3.13% Non -Rst Pwr Non - Resettable Power 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Reset Pwr Resettable Power 0.000 0.000 1.59 0.00 20.40 0.00% Total Standby Current (Amps) 0.085 0.740 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 2.040 0.062 Total Alarm AH Required Command Shortcuts Total Combined AH Required 2.10 Multiply By The Derating Factor 1.20 Print Page Minimum Battery AmpHours Required 2.52 SK -4 (3 amp version) on the Web Configure Circuits fe ;.'.',1 Circuit Configuration Project information Project framer Longstaff Condo Project ID: 0 Prepared By: Vlad Pain* Date: 5/20/2009 0 'd E ° 0 . r. Panel 1E). SK -4 ( iamb n c O . C1 t PO /trie Inroatrna Device Gkt I DewCe Current Draw Each Current Draw ,al - , ,�.. ,.x ,a, Standby Alarm rtardby Alai rn Unused o -000 a 000 _ 0 0. ooc Unused 0.000 0000 0 .000 0.000 Unused 0.000 _ 0 1 n 000 1 0. 000. � Unused I 0O0, 0 0 000 1 0 000 i 0000 _ 0 000 Totals ', ,.. -- Ckt. Number IDC 2 I is,, x Panel (U: 5K-4 (3 amp version).. CO . Name. Inniatmg Device Dkt 2 Qiy 'Device Currant Draw Each Current Draw Iota' r .. Star iby Alain E�rand55 Alarm 1 Unused 0000 O.00O O0o0 0.000 Unused 0.000 0.000 I 0 000 0.000 Unused 4000 ( 0'100 0 000 0 000_ Unused 0 . 000 1 0000 0 000 0.000 T 0.000 0000 Totals, 0.00) 1 0 000 Ckt. Nwnner IDC I : I Panel ID: SK -4. (3 amp version) Cot. Name: Initiating Device Clst 3 C1iy a D o w ce Canard Draw Each Current Draw Total . x Standby. Alarm Standby. Alarm Unused -- - -- - -__ -- 0 000. i 0 000 0.000 1 0.000 __ Unused 0.000 0.000 0000 0000 Unused :.. 0.000 0.000 0.000 0.000 Unused 0 000 0.000 0 000 0.000 0000 0.000 Totals j 0 000 1 0 000 Ckt Number IDC -4 Ckt. Name: balloting Der, - ice 541 a. Qty Deg ,, •rsni Draw E ach Current Draw T otal - -_ _ -_ -_ .___ -_____ _ _ Standby Alarm _Standby Alarm Unused 0 000 I 0.0005 0,000 T O 00 Unused 0 000 0000 0.000 _I 0 000 Unused 0000 0 000 0 000 I 0 000 Unused 0000.1 0000 0000 _ ➢OJ ` - __- _. _ I, 0000 I, ....0000 1 Totals :... 0.000 I .0 .000 Panel ID: 5K-4 (3 ump version) Ckt. Name: Notification Ape, Ckt 1 : Max Circuit Current: 2.5 Amps ,= ce CCurrent Draw Each Current Draw Total Y^ . . <ecz' ` ^ *: %=�i _ - ;4�_ Standby Airum Tdrrdhy Alar 6 _ ystem Sensor H12/24 Horn 0 0 025 0 000 c 50 _ ' I 1 System Sensor P24110 Nom/Strobe 0.000 0 165 0 000 j 0 1 65 I I I Unused 9 t lo00 o coo I o ont_ srT 0*000 0 000 t Unused �"' :, '' I ..,0,000. 0 000 '..I Totals =:_ . , 0.315 I Gel : NUrntier DAG -2 Panel ID SK a ti zday : rsen; CId. Name Notification Appi Cki 2 Max Ciral . Current: 2 5 A , ps Qty Device Current Draw Each Current Drive lot.' o-- .r. ' . Standb Alarm, Standby_ Alarm _ 10 System Sensor H12/24 Horn 0 -000 0 -025 0.000 0 250 y Unused 0.000 0 000 i 0. , 0. ace Unused _ 0.000 0 000 _4 . 0 .000 0.000 , Unused `-A.000 L 0000 0.00 I 0 000 i , 1_ 000 i 0000;_1 T otals OC 0,250 Ckl. Number: Non-Bst Pwr Panel ID: SK-4 (3 crop version) - Ckt. Name. Nor.- Aeeetlable Power - Max CirCint Current 5 Amps • Orr Device Current Draw Each Current Draw Total Standby Alarm : . Standby Alarm ' Unused _ 0000 0000 _ 0 000 0000 Unused 0 000 0 000 � 0 000 ± .... 0 000 ' o Unused 0.000 0 000 0 000 I 0 coo Unused _; ?.000 0 pop__ 0.000 I 0.000 I r -.. 0.000 1 0.000 I Totals l 0 000 10 000 1 FIRE ALARM CONTROL PANEL SK -4 & SK -4E Fire Alarm F Control Panel t 4 -zone fire protection at a price that won't burn your budget. The SK -4 and SK -4E (SK -4 /E) are four zone conventional fire alarm control panels (FACPs) that bring the latest in microprocessor technology to conventional fire controls. The SK -4 is a 120 VAC FACP and the SK -4E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small- to medium -sized commercial, industrial, and institutional buildings. For more information about the SK -4 /E system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763- 493 -6435. Description • Support for synchronization of The four zone SK 4/E is a 24 VDC standard ANSI audible signals and FACP that provides four Class B ADA compliant strobes per NFPA 72 initiating device circuits and two Class • Selectable for System Sensor, B notification appliance circuit (NAC). Wheelock, and Gentex protocols • Selective silence feature allows The SK -4 /E NAC protocol includes the manual silence of horns while strobes ability to silence audible devices while continue to flash on the same NAC strobes continue to flash, using only a . Program for combination tamper single pair of wires. The SK -4 /E is also supervisory monitor and waterflow compatible with conventional input alarm on one zone - devices such as two- and four -wire • Silent or audible walk test operation smoke detectors, pull stations, mode .--, waterflow devices, tamper switches and • Alarm verification selectable per zone other normally -open contact devices. • Program each zone for supervisory or Activation of a compatible smoke fire with separate red and yellow detector or any normally -open fire LEDs alarm initiating device activates audible • Disable switches provided per zone SK and visual signaling devices, illuminates • Program NACS for Device Circuits (IDCs) indicating LED, sounds the piezo — Silence inhibit Initiating ( ) sounder at the FACP, activates the — Auto silence Operating Voltage: 22 VDC nominal; Standby FACP alarm relay, and operates an — Strobe synchronization Standby Current: 4 mA optional module used to notify a remote — Temporal or steady signal Alarm Current: 15 mA min station or initiate an auxiliary control — Silenceable or nonsilenceable Short- circuit Current: 40 mA max function. — Disable Loop Resistance: 1000 max The SK -4 /E is compatible with System • Form C alarm, trouble, and EOL Resistor: 4.7K 0, 1/2 watt Sensor® i detectors providing supervisory relays NACs Signaling Current: 2.5A @ 24 VDC advanced features such as drift • 3A total usable current with standard transformer or 5A compensation, maintenance alert, and total (2.5A per NAC) with additional freeze warning. Automatic • 6A total usable current with optional ( P ) second transformer (PN SK -TRM24 optional transformer, power - limited synchronization of audio /visual devices or SK- TRM24E) EOL Resistor: 4.7K 0, 1/2 watt is provided, using three selections for • Optional dress panel (PN SK- DP2 /4) Form C Relays manufacturer protocol. Types: Trouble, alarm, and Electrical Specifications supervisory Features SK -4 Primary AC: 120 VAC @ 50/60 Contact Ratings: 2A @ 30 VAC, • Four Style B (Class B) initiating Hz, 2.3A resistive device circuits (IDCs) SK -4E Primary AC: 240 VAC @ 50 Hz, • Two Style Y (Class B) notification 1.15A appliance circuit (NAC) Wiring: 14 AWG (2.0 mm with 600 V SILENT • Optional module converts all IDCs insulation min KNIGHT and NACs to Class A (PN SK -CAC4) 'i�► f by Honeywell FIRE ALARM CONTROL PANEL SK -4 & SK -4E . Fire Control Panel a I� Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK -41E. The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices, alarm notification devices, and an on -board annunciator. It shall be compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply, four Class B initiation circuits which shall accommodate heat detectors, smoke detectors, and manual pull stations. Smoke detection shall be achieved with either 2- or 4 -wire detectors that are compatible with the system. The initiation inputs shall be programmable as 1) verification zones in which detectors are automatically reset one time before signaling an alarm condition; or 2) combination waterflow supervisory zones that allows the FACP to distinguish between an alarm switch (waterflow device) and a supervisory switch (tamper) installed on the same circuit. The FACP shall have two 2.5 amp or 5 amp (with an additional optional standard transformer) programmable notification outputs. It shall have dedicated relays for alarm, trouble, and supervisory. It shall have two power outputs, one resettable and one non - resettable, each rated at 500 mA. The FACP shall have an on -board annunciator to indicate alarm, supervisory, trouble, and maintenance conditions. The annunciator must include LEDs for AC, GENERAL TROUBLE, ALARM SILENCE, WALK TEST, EARTH FAULT, AND LOW BATTERY. The annunciator shall also contain LEDs to annunciate fire alarms, troubles, supervisory, and maintenance by zone. The FACP must be fully operational from the annunciator and include buttons for ACKNOWLEDGE, ALARM, SILENCE, RESET, and WALK TEST. The annunciator must also have separate DISABLE switches for each zone and notification circuit.rr Electrical Specifications (cont) Installation SK -4XTM Auxiliary Output The SK-4 /E can be surface mounted Transmitter Module. Provides a Resettable and non - resettable using two key slots at the top of the supervised output for local energy Operating Voltage: 24 VDC nominal backbox and two additional 0.25" municipal box transmitter and alarm Current: 500 mA max, power - limited; diameter holes at the bottom, or semi- and trouble reverse polarity. total current for nonresettable power, flush mounted using the optional Trim resettable power and two NACs must Ring P/N TR -1 -R SK -4XLM not exceed 6.OA (requires additional LED Interface Module. transformer) Approvals SK -XRM24 NFPA 72; UL Listed; Battery 110 Volt Transformer 3 -6A. Type: Sealed lead acid only CSFM 7165-0559: 145; • Charging Circuit: 27.6 VDC @ 0.8A MEA 297- 01 -E -3 SK- XRM24E 220 Volt Transformer 3 -6A. max normal flat charge Ordering Information Charging Capacity: 18 AH SK-4 SK -RZA4 Size: 7 AH max allowed in FACP. 120 VAC Four Zone Conventional Remote Annunciator. Larger batteries can housed FACP in an RBB accessory cabinet SK -4XZM Compatible Initiating and NAC SK-4E Zone Relay Module. Devices 240 VAC Four Zone Conventional RBB See SK document PN 52612. FACP Remote Battery Box Accessory Mechanical Specifications Accessories Cabinet. Use if back up batteries are Cabinet Backbox Dimensions: SK-DP2/4 too large to fit into FACP cabinet. 14.5" W x 15" H x 3" D Dimensions: 16 "W x 10 "H x 6 "D Dress Panel. Allows access to the (36.83 W x 38.10 H x 7.62 D cm) panel controls but restricts access to P Digital Communicator Accessories Cabinet Door: system wiring. 14.677" W x 15.342" H x 0.375" D 5104B (37.28 W x 38.97 H x 0.95 D cm) SK -CAC4 Six -zone fire control communicator Cabinet Color: Red Class A Convertor. Converts Style B 5129 Telephone Requirements: (Class B) IDC5 to Style D (Class A) and Four channel slave fire communicator FCC Part 15 and Part 68 approved Style B (Class B) NACs to Style Z Type of Jack: RJ31X (two required) (Class A) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA Ts KNIGHT keep our product information up -to -date and accurate. We cannot cover all FORM# 350305 Rev. C 12/06 specific applications or anticipate all requirements. All specifications are Honeywell subject to change without notice. For more information, contact Silent Knight Copyright © 2006 Silent Knight by 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. .SYSTEM SENSOR " c4 A Mini -Horns The SpectrAlert'Advance series of mini -horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. SPECTFVklert A V N C E Features The MHR and MHW mini -horns operate at 12 and 24 volts and are 12 and 24V operation ideal for hotel, motel or residential fire system applications, where • a smaller notification device is desired. The mini -horns offer high • High and low volume settings and low volume settings, and temporal or non - temporal tones. The • Temporal and non - temporal tones horns can be mounted to single gang back boxes for aesthetically • Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini -horns can operate between 32 and 120 Mini - Alert' sounders degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings M .C1) LISTED APPROVED approved I `•x711 1728nO MEA7 •7-E 7135.1651196 SpectrAlert Advance Mini -Horn Specifications • Architectural /Engineering Specifications Mini -horns shall he a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini - horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync-Circuit" Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4,61 x 2.9'W x .45D Weight 2.67 oz. Operating Temperature Range 32 °F to 120 °F (0 ° C to 49 °C) Mounting Surface: single -gang back box Flush: 4 "x 4" BBD deep back box (2 deep) Electrical Specifications Input Terminals 12 to 18AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8 -33 Operating Voltage with MDL 9 -33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8 - -175 VDC 8 - -17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16 33 VDC 16 - -33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non - temporal High 72 71 75 74 80 79 4 Non - temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) 8 -17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non - temporal High 22 17 . 29 25 4 Non- temporal Low 17 13 21 19 Ordering Information Part No. Description MHR r Mini -Horn, Red MHVV Mini -Horn, White *' 1167E # 020075ysttm Sensor. ✓ // J lI -= 3825 Ohio Avenue • St. Charles, IL 60174 RmtetsperlfrAonsatMectto change wimarc notice.tm6t Mtemsensorcom for SENSOR Phone: 800- SENSOR2• Fax: 630- 377 -6495 Current product Information, including the latest vasioi ar this data sheet. A05.0414000. 1/07.41743 SYSTEM SENSOR Selectable Output F Horns, Strobes, and Horn /Strobes ash, SpectrAlert* Advance selectable - output horns, strobes, F :` and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAlert Features The SpectrAlert Advance series of notification appliances is • Electrically compatible with existing SpectrAlert products designed to simplify installations, with features such as plug in • Automatic selection of 12 or 24 -volt operation at 15 and 15/75 designs, instant feedback messages to ensure correct installation of candela individual devices, and 11 field - selectable candela settings for wall and ceiling strobes and horn /strobes. • Plug -in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, When installing Advance products, first attach a universal mounting 30, 75, 95, 110, 115, 135, 150, 177, 185 plate to a four -inch square, four -inch octagon or double -gang • Same mounting plate for wall- and ceiling -mount units junction box.The two -wire mounting plate attaches to a single -gang • Shorting spring on mounting plate for continuity check before junction box. installation Next, connect the notification appliance circuit wiring to the SEMS • Tamper resistant construction terminals on the mounting plate. • Outdoor wall and ceiling products rated from —40 °F to 151 °F • Design allows minimal intrusion into the back box Finally, attach the horn, strobe or horn /strobe to the mounting plate • Horn rated at 88+ dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the • Rotary switch for horn tone and three volume selections mounting plate's terminals. The device will temporarily hold in place • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) with a catch until it is secured with a captured mounting screw . outdoor requirements • Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification Compatible with MDL sync module appliances. Outdoor strobes and horn /strobes (two wire and four • wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. SIGNALING 70 7125- 1653.1868ndoor strobes) MEA 7300-1653 (ou[doa Arobes) 7 125- 1653:188 (horrBllobes. approved chimtrobes) LISTED APPROVED rail 7135-1653.189(han /s s, climes) • 54011 3023172 M06452 -054 55512 53593 SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4 x 1 -inch back box, 4 -inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 1 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spear Alert Advance products, when used with the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn /strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective. service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn /Strobe Combination The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn /strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn /strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn /strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn /strobe models over a single pair of wires. The module shall mount to a 4 x 4n/16 x 21/2-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PhysicaliElectrical Specifications Standard Operating Temperature 32 °F to 120°F (0 °C to 49 K Series Operating Temperature —40 °F to 151°F ( -40°C to 66 °C) Humidity Range 10 to 93% non - condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 x 2.5 "high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7W x 2.50 (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61x4.7Wx1.3 mm Lx119mmWx33mm Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91. x 5.0W x 2.20 (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1 "diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1W x 2.0D (145 rnrn L x 130 rnrn W x 51 rnrn 0) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 "diameter x 2.0" high (180 mm diameter x 51 mm high) Wall -mount trim ring dimensions (TR -HS, TRW -HS) 5.71 x 4.812W x 0.35D (146 mm L x 122W mm x 9 D mm) Ceiling -mount trim ring dimensions (TRC- HS,TRCW -HS) 6.9 "diameter x 0.35 high (176 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 605 -0395 -005 UL Current Draw Data - UL Max. Strobe Current Draw (mA RMS) UL Max. Morn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15° 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75' 142 148 77 81 Temporal Medium 44 49 58 69 30' NA NA 94 96 Temporal Low 38 44 44 48 75" NA NA 158 153 Non - temporal High 57 56 69 75 95' NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 SO 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DClnput 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non- temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16 -33 Volts 16-33 Volts DClnput 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn /Strobe Output (dBA) ratings must be reduced in accordance with this table. 8 -17.5 16 -33 24 Volt Nominal Strobe Output (cd} Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32 °F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 ' 76 83 80 94 89 75 44 4 Non - temporal High 82 82 88 88 93 92 100 100 95 70 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 78 85 85 90 90 97 98 150 150 9t Coded Low 75 75 81 81 88 85 96 92 177 177 tSettings 7, 8, and 9 are not available on 2 -wire horn /strobe. 185 185 A9.`- 0195-005 SpectrAlert Advance Dimensions 5.98" PC2R* PC2RH* PC2RK° PC2RHK° PC2W*t PC2WH *t PC4R PC4RH PC4RK PC4RHK° 1« Wall Horn /Strobes Strobe, Standard cd, Red SRH *t Strobe, High cd, Red SRK° Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn /Strobes Wall -mount horn /strobes Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description P2R *t 2-wire Horn /Strobe, Standard cd Red • P2RH* 2 -wire Horn /Strobe, High cd, Red P2RK * ° 2 -wire Horn /Strobe, Standard cd, Red, Outdoor P2RHK° 2 -wire Horn /Strobe, High cd, Red, Outdoor P2W* 2 -wire Horn /Strobe, Standard cd, White P2WH* 2-wire Horn /Strobe, High cd, White P4R* 4 -wire Horn /Strobe, Standard cd, Red P4RH* 4 -wire Horn/Strobe, High cd, Red P4RK° 4 -wire Horn /Strobe, Standard cd, Red, Outdoor P4RHK° 4 -wire Horn/Strobe, High cd, Red, Outdoor P4W* 4 -wire Horn/Strobe, Standard cd, White P4WH* 4-wire Horn /Strobe, High cd, White Wall Strobes SR *t 2 -wire Horn/Strobe, Standard cd, Red 2 -wire Horn/Strobe, High cd, Red 2 -wire Horn/Strobe, Standard cd, Red, Outdoor 2 -wire Horn /Strobe, High cd, Red, Outdoor 2 -wire Horn/Strobe, Standard cd, White 2 -wire Horn/Strobe, High cd, White 4-wire Horn /Strobe, Standard cd, Red 4 -wire Horn /Strobe, High cd, Red 4 -wire Horn/Strobe, Standard cd, Red, Outdoor 4 -wire Horn /Strobe, High cd, Red, Outdoor SYSTEM SENSOR SCRH* SCRK° SCRHK° SCW*t SCWH *t Horns HR HRK° HW Accessories BBS -2 BBSW -2 BBSC -2 BBSCW -2 TR -HS TRW -HS TRC -HS TRCW -HS 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800- SENSOR2 • Fax: 630 -377 -6495 2.5' Ceiling -mount horn /strobes h `` 5.1 -4 Wall weatherproof back box Horn, Red Horn, White 6.2' Model Description Ceiling Horn /Strobes (cont d.) PC4W 4 -wire Horn /Strobe, Standard cd, White PC4WH 4 -wire Horn /Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red Strobe, High cd, Red Strobe, Standard cd, Red, Outdoor Strobe, High cd, Red, Outdoor Strobe, Standard cd, White Strobe, High cd, White Horn, Red, Outdoor Back Box Skirt, Wall, Red Back Box Skirt, Wall, White Back Box Skirt, Ceiling, Red Back Box Skirt, Ceiling, White Trim Ring, Wall, Red Trim Ring, Wall White Trim Ring, Ceiling, Red Trim Ring, Ceiling, White Ceiling weatherproof back box Notes: * Add " -P "to model number for plain housing (no "FIRE" marking on cover), e.g., P2R -P. t Add " -SP "to model number for "FUEGO" marking on cover, e.g., P2R -SP. # "Standard cif; refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings. "High cd: refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K "include a weatherproof back box. ❑ Add " -R "to model number for weatherproof replacement device (no back box included). 02008 System Sensor. Product specifications subject to change without notice.Vmit systemsensoccon for current product Information. including the latest version ofthbdata sheet AOS -0395 - 005.8/08.82018 Honeywell GENESIS SERIES CABLE Low Voltage ('able Part No. 3126 Description: 18 AWG 3/C CL2P /CMP Compliance: UL Standard 13, NEC Article 725 Construction: Conductor 18 AWG 16/30 STR Bare Copper No. of Conductors 3 Assembly Tubed jacket over twisted insulated conductors Insulation Type Plenum PVC Color Blk, Red, Wht Thickness 0.007" nom. • Diameter 0.060" nom. Lay Length 2.5" nom. Jacket Type PVC Plenum Thickness 0.015" nom. Diameter 0.160" nom. HONEYWELL 18 AWG 3/C (ETL) CMP -CL2P 3038058 (RoHS) W, /O# XXXXXX -XXX C(ETL) FT6 Legend (Ink Print) XXXXXFTRM #ABCDEF12345678 Properties Temperature Rating -20 to 60 ° C Operating Voltage 300 Volts max. Capacitance 28 pf /ft nom. Impedance 72 Ohms nom. • DC Resistance 6.5 Ohms /M' at 20 ° C Flame Rating UL 910, CSA FT6 • SYSTEM �$ SENSOR t Photoelectric Smoke Detectors System Sensor's i series smoke detectors represent significant advancement in conventional detection. The i family is founded on three principles: installation *M ease, intelligence, and instant inspection. Features Installation ease. The i line redefines installation ease with its Plug-in detector line, mounting base included plug in design.This allows an installer to pre -wire the bases included • with the heads.The large wire entry port and in -line terminals • Large wire entry port provide ample room for neatly routing the wiring inside the base. • In -line terminals with SEMS screws The base accommodates a variety of back box mounting methods, • Mounts to octagonal and single -gang backboxes, 4- square as well as direct mounting with drywall anchors.To complete the backboxes, or direct to ceiling installation, i heads plug in to the base with a simple Stop -Drop 'N Lock' action. • Stop -Drop 'N Lock attachment to base • Removable detector cover and chamber Intelligence. i detectors offer a number of intelligent features • Built-in remote maintenance signaling to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i line to minimize • Drift compensation and smoothing algorithms nuisance alarms.Two -wire i3 detectors needing cleaning can • Simplified sensitivity measurement generate a remote maintenance signal, when connected to the Wide angle, dual color LED indication 2W-MOD2 loop test/maintenance module, or to a panel equipped • with the i protocol. This signal is indicated by LEDs located at the • Loop testing via EZ Walk feature module and the panel. The SENS -RDR, a wireless device, displays the • Built -in test switch sensitivityof i detectors in terms of percent per- foot - obscuration. Instant inspection. The i series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test /maintenance module or a panel with the i protocol, the EZ Walk loop test feature is available on two -wire i detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ( ® ) MEA kISFM • LISTED APPROVED ICI approved approved _, ?31 29C - 01 - 2_:93 rh Smoke Detector Specifications • Architectural/Engineering Specifications Smoke detector shall be a System Sensor i Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W -B) or a combination photoelectric/thermal (Model 2WT -B, 4WT-B) with thermal sensor rated at 135 °F (57.2 °C).The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a plaster ring, or direct mount to.the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre - wiring of the base and the head shall be a plug -in type.The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT -B, 4W1-B) conditions. When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non - polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2 -wire: 100 pA; 4-wire: n, /a Alarm Contact Ratings 2 -wire: n/a; 4 -wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 63 oz. (178 grams) Operating Temperature Range 2W -B and 4W -B: 32 °F -120 °F (0 °C- 49 °C); 2WT-B and 4WT -B: 32 °F -100 °F (0 °C- 37.8 °C) Operating Humidity Range 0 to 95% RH non - condensing Thermal Sensor 135 °F (57.2 °C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41 °F (5 °C) Sensitivity 2.5%/ft. nominal Input Terminals 14 -22 AWG Mounting 3 -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W -B No 2-wire 130 mA max. limited by control panel 2WT -8 Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA @ 12V, 23mA @ 24V 41NT B Yes 4 -wire 20 mA @ 12V, 23mA @ 24V Accessories 2W -MOD? 2 -wire loop test / maintenance module RT Removal / replacement tool SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter C2* SntM. :,or 3825 Ohio Avenue • St. Charles, IL 60174 htvxKtyx F a:k zvRrectU.:harx,Nmx . nMi:^ot'tsystFrx , nraellot SENSOR Phone: 800-SENSOR2 • Fax: 630- 377 -6495 <wag przzluo iironation. "`k`x" "KlamAl ' aa`ashe` ". A05.0318.006. 7/06 • #1676 ' CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS -DA and PS -SA Conventional Pull- stations s 4 Easy to Install and Operate A The PS- DA/PS -SA Pull Stations are non -coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS- DAPS -SA pull stations includes both single- action and dual- action models equipped with key lock / reset. It was designed to meet multiple applications with the installer and end -user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS -SA simple to install, maintain, and operate. Operation `mii` r 0 The single- action pull- station is v a ctivated by a single pull -down of � � ; r�� the alarm handle. The dual- action versions require pushing in the t.MPuJE'r I t Ili Tf • handle, then pulling the handle � i�j down for activation. The PS 11. ,t p' nt rv-, 4 DA/PS -SA manual pull stations are ' UL listed and meet the ADA requirement of a 5 -lbs. maximum pull force to activate. Operating__ .�- instructions are molded into the handle along with Braille text. , , t t Molded terminal numbers can be D ; , ± t' t found adjacent to the wiring termi- w nals. S i 1 1 Models: PS -DA PS -DASP PS -SA— Single action with 'pigtail' Features: Specification: connections and a key lock reset. • UL Listed Dimensions: Pigtail wires are provided for con- . CSFM Listed Height: 5 -1/2" (13.97 cm) nection to the Fire Alarm Control Width: 4" (10.16 cm) Panel's (FACP) initiation circuit. • Meets ADA requirements Depth: 1- 7/16" (3.65 cm) • Operating instructions are mold- Operating PS -DA — Dual action model with ed into the handle along with temperature: 32 °F to 120 °F screw terminal connections and a Braille text. (0 °C to 49 °C) key lock reset. • Made of durable Lexan Electrical: Switch Contact PS -DASP — Same as PS -DA • Available in Spanish Rating: 0.25A@ 30 VAC except with both English and K ey resettable or VDC Spanish operating instructions. • Easy to Install and operate SILENT Y p Accessories: . Iti KNIGHT • Single or dual action SB -v0 Surface Mount • Surface mount box available Back -box by Fioneroleti BG -1 R Trim Ring CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS -DA and PS -SA Conventional Pull- Stations P i Engineering Specification Manual Fire Alarm Stations shall be non -code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back -box SB -10; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national /local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE /FUEGO" on the PS -DASP shall appear on the front of the station in white letters, approximately 3/4" high. 4r �.. + FIRC F IRE ►��� d . : e; a € • t f to ` `i 1 f S, , : Ti] 1 A 4 r l' . ,, - r 4 MO D ` . DI 'i PS -SA Front View PS -DASP Front View PS -SA Rear View PS -DA Rear View SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA ij keep our product information up -to -date and accurate. We cannot cover all P/N 350241 Rev. B specific applications or anticipate all requirements. All specifications are sub- © 2008 Honeywell International Inc. - ject to change without notice. For more information, contact Silent Knight lid 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. • Phone: (763) 493 -6400 or (800) 328 -0103, Fax: (763) 493 -6475. www.silentknight.com