Loading...
Permit • y U CITY OF TIGARD MASTER PERMIT : COMMUNITY DEVELOPMENT Permit #: MST2012 -00302 T 1GARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 02/25/2013 Parcel: 1 S 133CA14700 Jurisdiction: Tigard Site address: 11084 SW MALLOW TER Subdivision: VILLAGE AT SUMMER CREEK Lot: 70 Project: Village at Summer Creek, Lot 70 Project Description: Building 20, new SFA. Includes residential fire sprinklers. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 40 sf Basement: 0 sf Left: 10 Parking Spaces: 0 Height: 32 Bathrooms: 3 Second: 573 sf Garage: 480 sf Front: 8 Smoke Dwelling Units: 1 Third: 573 sf Right: 3.5 Detectors: Yes Total: 1186 sf Value: $145,059.44 Rear: 3.5 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs /Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 0 Drywell- Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc!Feeders Branch Circuits 1000 sf or less: 1 0 -200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0 Ea add! 500 sf: 2 201 -400 amp: 0 201 -400 amp: 0 W/O Svc/Fdr: 0 Mfd Home /Feeder /Svc: 0 401 -600 amp: 0 401 -600 amp: 0 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY • SF Residential Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: V BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R -3 1186 Owner: Contractor: CENTEX HOMES CENTEX HOMES Required Items and Reports (Conditions) 3884 SE AERIE AVE 11241 SLATER AVE NE STE 100 1 Ersn Cntrl 503 - 639 -4175 HILLSBORO, OR 97123 KIRKLAND, WA 98033 PHONE: 971- 246 -1417 PHONE: 425- 216 -3400 FAX: Total Fees: $13,975.57 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -00 s hrough • R 952- 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling .232.1987 or 1.800 332.2344. Issued B \ ! %u .�. Permittee Signature: i tg. Call 503.639.4175 by 7:00 a.m. for the next available inspection da . This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • . Building Permit ApplicatU E"ED Residential DEC 1 1 2012 City of Tigard OF TIGARD Received /• ry , g— Permit No.: f y 7p .o/A.-456 302 • 13125 SW Hall Blvd., Tigard, OR Phone: 503.639.4171 Fax: 5(g �. +� G DNI Plan Review t, Uare/By : 2 ?i 71 ( - OtherPermir: vFw2eZol� - 3�0 . l - 1 i_ q It D Inspection Line: 503.639.4175 Date Reams: „�^ huia ® See Page 2 for Internet: www.tigard -or.gov N ( f I r'fJ g Supplemental Information U ti TYPE OF WORK REQUIRE DATA: 1- AND 2- FAMILY DWELLING ® New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all El Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indi •: ted on this application- ® I- and 2- family dwelling ❑ Commercial/industrial Valuation: • .t S136,8 09 34 i6rf7 44 ❑ Accessory building ❑ Multi - family Number of bedrooms: 2 ❑ Master builder ❑ Other: Number of bathrooms: 3 JOB SITE INFORMATION AND LOCATION / Total number of floors: 3 Job site address: 1 / r0 1( S w Th �o L-. - T r f' c e New dwelling area: 1186 square feet City /State/ZIP: TIGARD OR, 97223 Garage/carport area: 480 square feet .5 3 Suite/bldg. /apt. no.: - ) I -D Project name: VILLAGE AT SUMMER CREEK Covered porch area: 18 square feet 673 Cross street/directions to job site: CORNER OF SW BARROWS RI), Deck area: 128 square feet 4-0 SW 135 AVE, AND SW SCHOLLS FERRY RD Other structure area: ( ��� square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: VILLAGE AT SUMMER CREEK Lot no.: 7 Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. NEW SFR TOWNHOUSES Valuation: S UNIT C 1186 SQ. FT. Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: CENTEX HOMES Type of construction: Address: 3884 SE Aerie Ave. Occupancy groups: Y gro ps: City/State/ZIP: Hillsboro OR, 97123 Existing: Phone: (971)246 -1417 Fax: (503)608 -3061 New: ® APPLICANT ❑ CONTACT PERSON NOTICE Business name: CENTEX HOMES All contractors and subcontractors are required to be Contact name: Bill Waggoner licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 3884 SE Aerie Ave. jurisdiction in which work is being performed. If the City / State/ZIP: Hillsboro, OR 97123 applicant is exempt from licensing, the following reasons apply: Phone: (971) 246 -1417 Fax: : (503) 608 -3061 E -mail: bill.waggoner@pulte.com CONTRACTOR Business name: CENTEX HOMES BUILDING PERMIT FEES" Address: 3884 SE Aerie Ave. (Please rdQ mfersd►e+drr &) City/State/ZIP: Hillsboro OR, 97123 Structural plan review fee (or deposit): Phone: (971) 246 -1417 Fax: (503) 608 -3061 FLS plan review fee (if applicable): CCB lic.: 182591 Total fees due upon application: ` Amount received: th Authorized signature _ This permit application expires if a permit Is not obtained within 180 days after it has been accepted as complete. Print name: Dave Templeton I Date: s S �j/ L I • Fee methodology set by Tri Building Industry /// Service Board. I: \Building\Permits\BUP -RES PermitApp.doc 10/01/09 4404613T(I 1 /02/COM/WEB) ( S o 3 .`77-5- • •. J Plumbing Permit ApplicCEiD Building Fixtures FOR OFFICE t SE ONLY City of Tigard pt : C 1 1 2012 Date/By: /X if /1 ( h Permit No fl%r ?e!9 -op .30 IN • 13125 SW HaII Blvd., Tigard, OR 97223 �p � Plan Review . Phone: 503.639.4171 Fax: Ei r.�B Date/By: Other Permit No;f91oQ 8.o11 -0002. TIGARD Inspection Line: 503.639.41U s BUILDING DIVISION Date Ready /By: tuns 68 See Page 2 for Internet: www.tigard - or.gov Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ® New construction 0 Demolition For special information use checklist. Description I Qty. I Ea. I Total ❑ Addition/alteration /replacement ❑ Other: New 1 - 2 - family dwellings (includes 100 ft. for each utility connection CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® I- and 2- family dwelling ❑ Commercial /industrial SFR (2) bath 437.78 SFR (3) bath I 500.32 500.3 ❑ Accessory building ❑ Multi- family Each additional bath/kitchen 25.02 ❑ Master builder ❑ Other: Fire sprinkler ( sq. ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: ii 0 S // to [(0 T Drywall, leach h line, 1. Catch basin or drain 18.76 ne, or trench drain 18.76 City /State /ZIP: TIGARD OR, 97223 Footing drain (no. linear ft.: N) 1 Page 2 Suite/bldg. /apt. no. Project t name: VILLAGE AT SUMMER CREEK Manufactured home utilities 50.03 Cross street/directions to job site: CORNER OF SW BARROWS RD, Manholes 18.76 SW 135 AVE, AND SW SCHOLLS FERRY RD Rain drain connector I 18.76 Sanitary sewer (no. linear ft.: 1.00) I Page 2 Storm sewer (no. linear ft.: 100) I Page 2 Water service (no. linear ft.: 100) I Page 2 Subdivision: VILLAGE AT SUMMER CREEK I Lot no.: 70 ____ Fixture or item: Tax map /parcel no.: Backftow preventer 31.27 Backwater valve 12.51 DESCRIPTION OF WORK Clothes washer I 25.02 NEW SFR TOWNHOUSES Dishwasher I 25.02 UNIT C 1186 SQ. FT. Drinking fountain 25.02 Ejectors /sump 25.02 ® PROPERTY OWNER l ❑ TENANT Expansion tank 12.51 Name: CENTEX HOMES Fixture/sewer cap 25.02 Floor drain /floor sink/hub 25.02 Address: I 338 .s flat^; e Ave Garbage disposal I 25.02 City / State/ZIP: / l)S.}7o /0, OR q 7/3 Hose bib 2 25.02 Ice maker I 12.51 ❑ APPLICANT ® CONTACT PERSON Interceptor /grease trap 25.02 Business name: CENTEX HOMES Medical gas (value: $ ) Page 2 // lti n et' Primer 12.51 Contact name: Roof drain (commercial) 12.51 Address: 38,3' S E / e`I D AB Sink/basin/lavatory 5 25.02 City /StaterLlP: ;f /, J fc 0 R 7j 3 Solar units (potable water) 62.54 Fax: : (503) 608 - 3061 Tub /shower /shower pan 2 12.51 E-mail bill. '-' , ere Pu / fr. CO/y.% Urinal 25.02 '/ Water closet 3 25.02 CONTRACTOR ■ Water heater I 37.52 Business name: CRAFTWORK PLUMBING INC. Water piping/DWV 56.29 Address: 7737 SW CIRRUS DR Other: 25.02 City /State/ZIP: BEAVERTON OR, 97008 Subtotal Minimum permit fcc: 572.50 CCB Lie.: 79666 Plumbing Lic. no.: 20 - 148PB Plan review (25 % of permit fee) /74,, State surcha (I 2% of permit fee) Authorized signature: A - TOTAL PERMIT FEE Th is permit application expires if a permit is not obtained within 180 days I Print name: PETER POLLARD Date: 0" f?../0 after it has been accepted as complete. 'Fee methodology set by Tri -County Building Industry Service Board. 1 1 Building \Permits \PLAtti- PermitApp doc 10101/09 440-4616T( t0/O2/COM/WEB) _ .. RECEIVED Mechanical Permit Application ,, n FOR OFFICE USE ONLY City of Tigard DEC 1 1 2012 Received �ij 11 �� l. - � A Ilig g Re a Received /y 8 Y Permit N o.: U ✓ q 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review o Phone: 503.639.4171 Fax: 503 � TIGARD Other Permit o1 w Q-2cri2.• -0oe1 Inspection Line: 503.639.4175 Date/ Ry. TI °A RD B UILDING DIVISION Date Ready/By. echo Supplemental See Page 2 for Internal: www.tigard or.gov Notified/Method: Supplemental Information in _ "-'1 .-4-'; 1;;i:01 .f.A.',1,', sri 4i .jaRgi:M 4f 'f r c� I R c V L;r1 r k e. : a 1 C 1. a , r[7 a, 6 e Al S i !• Mechanical permit fees are based on the value of the work ® New construction ❑Addition /alteration /replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit i r . 1 W*,- o i5 ?i5: :u 'e c1Ir `+t ` ? 4;ic ' ir.t. g ( � Value: $ hx ,k:1' 3 \,Ili iiiitl i. 0 011' 17 nr /, I ]I stx ® I- and 2- family dwelling ❑ Commercialindustrial ❑ Accessory building "� / "- " ° IJ� , "''` For special information use checklist. ❑ Multi- family 0 Master builder ❑ Other: Description I Qty. I Ea. I Total u•'a . ;1; ; ;t 4,%Cai ! Iali-itrif4i_Qa 1 111 0 � 1(a i�i . 70e O., r1.tg,I .,,W�: �.�`_ _ .�, . ..� Heating/cooling "1/0„, ^ Air conditioning Job site address: I ) 3'1 S J r/ k (� (requires site plan showing placement) 46.75 City/ State/ZIP: TIGARD OR, 97223 Furnace 100,000 BTU (ducts/vents) 1 46.75 46.75 Furnace 100,000+ BTU (ducts/vents) 54.91 SuitefbldgJapt. no.: 9,0 I Project name: VILLAGE AT SUMMER CREEK Heat pump 61.06 Cross street/directions to job site: CORNER OF SW BARROWS RD, Duct work 23.32 SW 135Th AVE, AND SW SCHOLLS FERRY RD Hydranic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Flue/vent for any of above 23.32 Subdivision: VILLAGE AT SUMMER CREEK I Lot no.: 7 _ Other: 23.32 Tax map /parcel no.: Other fuel appliances rr,fw•a 7 7 - 'rtT :•^iu4 - "M IL • €1111 ;1~! W -: ��. 0 ;t:1 i e i, :..1W } Water heater 1 23.32 23.32 Gas fireplace 33.39 NEW SFR TOWNHOUSES for Flue vent for water heater or gas UNIT C 1186 SQ. FT. fireplace 23.32 Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 k' =' A : a ■u f r1 j Z..irk. yr-.,R . + z- ' = W' • ice` . °� 0t Chimney/liner/flue/vent 23.32 - �a :;rs (]t �k..•�`s• •�,L`.�•,a: Other. 23.32 Name: CENTEX HOMES Environmental exhaust and ventilation Address: 1 38811 SE ,4er; a /1 U Range hood /other kitchen e equipment 1 33.39 33.39 City/ State/ZIP: 1 1445 6 c , o Q q71 a 3 Clothes dryer exhaust 1 33.39 33.39 Single-duct exhaust (bathrooms, Phone: ( q71- d y6 - ) L1 1-7 Fax: (503)608 -3061 toilet compartments, utility rooms) 4 23.32 93.28 "� `a' eI:jis: y c am =} �' ^4g :`'pi:7.f O O •,g (i FRS Attic/crawlspace fans 23.32 rt ' ti,riYA- ._':i6: ®`�t�!�- �iL�rr3C'i,'.J: a, . Business name: CENTEX HOMES Other. 23.32 Fuel piping Contact name: g,// k,p 9 o /It e " $14.15 for first four; 54.03 for each additional Address: 3 88 4 . / '4 r; a A ✓ !? Gas heaea h pt pump p City/ State/ZIP' J+;I/ 0 1 9 7A Wall/suspended/unit heater Phone: q-- _/ j 7 Fax: : (503) 608 -3061 Water heater 1 Fireplace E -mail: 12'!!. w 40. 0/I - / - , rr7 Range I i r r*r7j v s � 100}' i '. ? p r ea ti: k�5-y sI ; "4 ,:- 1 . ro Barbecue �1.. -. .., d - Jw..u .Yl... )- .G�7t� .slaw � - O- ,�+Jl �%� •R ~J:' - �i•aa1 . 0 Y. f Business name: MUEHE QUALITY HEATING INC. Clothes dryer (gas) Other. Address: 7301 SW !CABLE LANE, STE 500 '' • --f.64 y 'n5 iIA41.A:; r '• ; City/State/ZIP: PORTLAND OR, 97224 Subtotal Minimum permit fee ($90.00) Phone: (503) 598 -0966 I Fax: (503) 598 - 8498 Plan review (25% of permit fee) CCB lic.: 50096 State surcharge (12% of permit fee) TOTAL PERMIT FEE Authorized signature: - This permit application expires if a permit Is not obtained within 180 days after it has been accepted as complete. I Print name: KYLE Date I • Fee methodology set by Tri- County Building Industry Service Board 1: 10uildv :g\PermitsiMEC- PermitApp.dcc 10/01/09 440.4617T (I I /02/COM/WEB) Electrical Permit A licati FOR OFFICE USE ONLY City of Tigard Received ° 13125 SW Holt BIvd.,Ti ard,OR 97223 � 123 Date/By: /2. / / //r Cl-f7 PcmlitNo.: H Orgy/ } �.� -7- n g Date/By: ao► �'O Plan Review Phone: 503.639.4171 Fax: 503.598. Other Permit: U o y ' 02 T I GA RI) Inspection Line: 503.639.4175 " � � 1 201 1 2 3 Date Ready/By: Juris: Br see l'age 2 for Internet: www.tigard or.gov Notified/Method: Supplemental Information • Addition /a e TYPE ' A TIGARD PLAN'REVIFiW ® New construction ❑ ill 1 , 14, rftratgilraiiON Please check all that apply (submit 2 sets of plans w /items checked below): ❑ Service or feeder 400 amps or more ❑ Building over three stories. ❑ Demolition ❑ Other where the available fault current ❑ Marinas and boatyards. • CATEGORY OF CONSTRUCTION exceeds 10.000 amps at 150 volts or ❑ Floating buildings. El - and 2 - family dwelling 0 Commercial/industrial less to ground, or exceeds 14.000 ❑ Commercial -use agricultural 0 apps for all other installations. buildings. ❑ Multi - family ❑ Master builder ❑ Other: ❑ Fire pump. ❑ Installation or 75 KVA or JOB SITE INFORMATION AND LOCATION ['Addition Emergency system. larger separately derived system. ❑ Addition of new motor load of ❑ "A ", `E ", "I -2 ", `I -3 ", Job no.: Job site address: � "4/4— T 10010' or more. occupancy. ( I 0 g J ( S c--- 1 f'�. ❑ Six or mom residential units. ❑ Recreational vehicle parks City/State/ZIP: TIGARD OR 97223 ❑ Health -care facilities. ❑ Supply voltage for more than ❑ Hazardous locations. 600 volts nominal. Suite/bldg. /apt. no.: 9 � I Project name: VILLAGE AT SUMMER CREEK ❑ Service or feeder 600 minas ormom. FEE SCHEDULE Cross street/directions to job site: CORNER OF SW BARROWS RD, Deacrlpron I Qty. I Fee. I Total I • nt New residential single- or multi - family dwelling unit. SW 135 AVE, AND SW SCHOLLS FERRY RD Includes attached garage. Subdivision: VILLAGE AT SUMMER CREEK Lot no.: 70 1,000 sq. R. or less _ I 168.54 168.54 4 Tax map /parcel no.: - — Ea. add'I 500 sq. R. or portion Z 33.92 I Limited energy, residential I 75.00 75.00 2 DESCRIPTION OF WORK (with above sq. ft.) NEW SFR TOWNHOUSES Lim residential h I above sq R.) 75.00 2 Services or feeders installation, alteration, and/or relocation 200 amps or less 100.70 2 ® PROPERTY OWNER I ❑ TENANT 201 amps to 400 amps 133.56 2 Name: CENTEX HOMES 401 amps to 600 amps 200.34 2 601 apps to 1,000 amps 301.04 2 Address: 38, if SFA enr C A Over 1,000 amps or volts 552.26 2 l y�s �Jo /0 R Temporary services or feeders installation, alteration, and/or City /5tatelZ1F. /4 , 971d3 relocation Phone: q 7 i -a y ( - /y /7 Fax: (503- 503 -6031 200 amps or less 59.36 1 Owner installation: This installation is being made on property that 1 own which is not 201 amps to 400 amps I25.08 2 intended for sale, le ren y �se t oLpchan e according to ORS 447, 449, 670, and 70 401 amps to 599 amps 168.54 2 tt Branch circuits - new, alteration, or extension, per panel Owner signatures • li - Date: 5 — 22 I_ A. Fee for branch circuits with ® APPLI NT I ❑ CONTACT PERS above service or feeder fee. 7 42 2 each branch circuit Business name: CENTEX HOMES B. Fee for branch circuits without service or feeder fee, first 56.18 2 Contact name: 053111 4.470ntl' branch circuit '� pm ,/ n Each add'I branch circuit 7.42 2 Address 300 ' ..SE /7e/':e A Miscellaneous (service or feeder not Included) City/State/ZIP Each manufactured or modular 67.84 2 Ci ty • /'�//(.s�0(0, OR 9 � id3 dwelling, service and/or feeder Phone. ' '• ?7I I Fax: : (503) 608 - 3061 Reconnect only 67.84 2 l Pump or irrigation circle 67.84 2 E-mail. d /l n� a -c Sign or outline lighting 67.84 2 CONTRACTOR Signal circuit(s) or limited -energy Business name: GARNER ELECTRIC panel, alteration. or extension. Paget 2 Each additional inspection over allowable in any of the above Address: 2920 SE BROOKWOOD AVE, STE A Additional inspection (1 hr min) 6625/ hr City / State/ZIP: HILLSBORO OR, 97123 Investigation (Ihrmin) 66.25/ hr Industrial plant (1 hr min) 78.18/ hr Phone: (503) 648 -4552 I Fax: (503) 642 - 7925 inspections for which no fee is 90,00 / hr specifically listed ('b hr min) CCB Lie.: 182591 I Electrical Lic.: 34 - 305C I Suprv. Lie.: _ , ELECTRICAL PERMIT FEES Subtotal: Suprv. Electrician signature, required: Plan review (25% of permit fee): Print name: CHUCK GARNE' I Date: State surcharge (12% of permit fee): Authorized signature: TOTAL PERMIT FEE: % This permit appikatloo expires If a permit is not obtained within 180 days after It has been accepted as complete. Print name: Date: • Number of inspections allowed per permit I. tauading \Pennus\ELC- PmnitApp.doc 07ro1/10 440 - 4615Th 1 I/0SICOMAVES III Building Division Development Code Provision Review T cA R ° Residential Projects Building Permit No.: H 0l a0 I - aD N o Site Address: 11 O ?q ,to H q-L w �� LO a Project Name & Lot No.: J, R,. cat. qr c l CQ.tEk, kof 70 CWS Service Provider Letter `l Required: Yes ❑ No 0` Received: Yes ❑ No L Routed Plans: Original Plan Submittal Date: /2- //I A 9 " 'l nn ,n- 1st Revision Submittal Date: A /it //3 ( Site Plan Only 2 ^d Revision Submittal Date: ❑ Site Plan Only To the Applicant: Each review type must be approved. If the plan is not approved, please revise and resubmit three (3) copies to the Building Division. Only checked (✓) items are approved. Items not approved and those listed in the notes must be revised prior to re- submittal. For questions please contact the appropriate staff person(s) listed above each section. Staff: please check items along left only if approved. //--� Planning Review (contact / at 503 - 718 - ;WO or /, @tigard- or.gov) Land Use Case No. `7 114' 2 0 o --/ 000/ Zoning TZ -3-'5' C 1>,) Setbacks: Front `3 Rear / b Side 3 S Street Side T h Garage 57 "Z-- 4 M Maximum Building Height: 1 1 S Actual Building Height — -. 7 " I2Y Visual Clearance Er , i / Easements E Sensitive Lands Type: v ❑ Street Trees Protected Trees / / Notes: 41 /i qS 4�1.Df hp. 5 �G /6-.eg ////,„,,,__, T,�e� a i--G� i s/ /1-€4, co-s-- �� /,4 ee "/ � :tt /VJ — CJ - << si r_ alltil i Original Plan: Approved ❑ " Not Approved Er Date: / 71/ � //2 Revision 1: Approved C� Not Approved ❑ Date: .1/ - / f j Revision 2: Approved ❑ Not Approved ❑ Date: (Review Continues on Page 2) Page 1 of 2 Engineering Review (contact Mike White at 503- 718 -2464 or MikeW @ tigard- or.gov) "r" Slope: Notes: Original Plan: Approved -Er Not Approved ❑ Date: / / Revision 1: Approved .Er Not Approved • ❑ Date: Slit f ( 7 Revision 2: Approved ❑ Not Approved ❑ Date: Permit Coordinator Review (contact Albert Shields at 503 - 718 -2426 or albert @tigard - or.gov) ❑ Conditions of Approval Prior to Issuance of Building Permit Notes : Original Plan: Date Sent to Appli ant: Revision 1: Date Sent to A►p ant Revision 2: Date Sent to • pp cant / r / Okay to Issue Permit: Yes Wi o q Date Routed to Building: I' Page 2 of 2 A 0 .,... Village at sw ,, A ' • . Ar ' ' 4 ,e1 1/42 o gef 4 k 0.. ii ■ i ll/re r4) _ Summer Creek 1 AIM :A 111 - P Amilt ) s - _ _ 0. .,„ EF DEC 1 4 CrrYOFTD ' 0 P AP ' BUILDING D li I 11 N ...----- - , , - .,,-• 11- _--- - _ • • • • • • A ti 8 .et6 ' . . 1 lo r: 74 . 6 ... .. ;l........ .,. 7 .... .. ....... • Inill . - ... 11 :0'. . . : :. C; ...... (:):.:- ;...;: ' . • 1 ''..... . .. it , 7 • A . . . .. . f.; - .., - . _sio"....- • • 1: \ . . .. . .... . . , .... . . .. ,.. . .... ... : . - , . . . .. ' i . . . ., % LLL_ _ :---,4,-,.-- Building Plan: 20 23.0 I 1 I Az y-- . I ,.. '6 I I Lots 69, 70, 71, 72 & 73 - -, .1. 0 _ ..,,_ 69 70 71 72 I RE EIVED E 1 1 2013 , I FF/TOW 188.93 I FF/TOW 189.93 /TOW 189.93 Units A-C-B-C-A .. -, . - /TOW 188.93 I I FF FF OW 189.93 ifY FT GARD , GS 188.23 I GS 188.23 I GS 188.73 GS 188.73 I \ TOP 188.39 TOP 188.39 I I GS 189.23 BVIII G D VISION TOP 189.39 ., TOP 189.39 TOP 18 ,. , SITE PLAN , . : ,, , , - , 1 1 I 9.39 - 1 i Scale: 1"-10' 0, 1- % I I I IF .. - 1 1 5v .,....... 1.4/.44( .,...,_ tP I I \ ----r 1-1 r J - -Ti II --- - - 7 - ...1 l C1 1 Set I k f:y7r f- 0 7 "7 1 0 3' I . . r . ■ ' " • • . r .....4._ _ _ .. A-- -,. \ 1 r I : • . " • ' 3.5' . . - - .•. . I 3 7 r • • . '. -, ,- - • • . • , 19.3' 1. . . ' • • • .' fel , 1 7 . . ' 19.3' ..: ,,; 173 173 1 ' . .• .; 1 4.3' 40 I ::' .. . ■ 1 3.3' 1 6.3' . i 1 4.3 i . .. • 1 : . I I 10 , ■ I '... . -, i , : . 1.. , 1 85. 3.5 I ". L... . I ' ..113.7-1 4,401.47, 1.88:,0 I I 188,7s I S'e L (70 iiright#6 e ,, - CI .,:.§:::■;;::;::;'/,::::::::::::k. hiket4Ziga,, ,. ! H ..... • ... 4 074.:0161.11;;;M P ITAMSL I ,::::::':::::Z;;.;.:;?:M§::.;::.:;;Z:.;*.;g•;.... Stl, M ';;',., VP' V.. 1.■ !wow- ,....- :;.AVR*444.04 ,, , - --..,-- - 4 ;^ 7 , - : 7 -' ' ' -,, ' ' - , _ ,‘ - - , - ..,- , _ - B Y:: : :: 11:K: ::,•••:,:, !.., ii.::. .:!: //11.i.. ..... y. , stiiiiiiiii •iitii:•iii:..:., //, w. isis :.v.::: , z,:...::::: - I • -.....--... .'. .. :.:.•:•.:: . :•:••••••::: :.::.:.:.:: : :::.:.:•: : , . ' ... 1 ENGINEERING ASSOCIATES CORPORATION t .... :... ............. .. . . . ... _ _ 17757 Kelok Road Lake Oswego, OR 97034 \ -1 ---- ,, Tel. (503) 636-4005 Fax (503) 636-4015 .. Job No.: CEN -090 Harper Date: 06/10/2013 � ° Houf Peterson To: Dave Cady, Pulte Group Righellis Inc. ENGINEERS • PLANNERS From: Steven J Entenman P.E., S.E. LANDSCAPE ARLMITEL T6•SURVEYORS Project/Subject: Summer Creek Townhomes — Building 20, Lot 69 & 73 ❑ Fax - Number: ; Number of pages M ou did not receive the correct number of pages, please call 503 -221 -1131) E-mail ❑ Mail ❑ Hand Deliver ❑ Interoffice Dave, // 9 "" t enALLow - V12/2— 14/frAo /,-c 5.2Q 2 Per our phone conversation with you, it is our understanding that the second level type "9" holdowns at the_front of the building were not installed as specified in detail 11 on sheet S7.0. Instead of wrapping the holdown straps around the beam as originally detailed, the bottom of the Simpson MST60 straps were aligned with the bottom face of the beam, and then secured to the front face of the beam and the holdown posts above. We have reviewed this existing condition, and determined that the reduced strap capacity is adequate to resist the code required uplift. We therefore take no exceptions to this existing condition. If you have any questions please do not hesitate to contact our office. Sincerely, S .t RUCTUe4 4 HARPER HOUF PETERSON RIGHELLIS INC. 3E0 PROFFf , 4' 320 R 12,M J OREGON . Steven J Entenman P.E., S.E. Y15 . ' 0° - 15;'0 ° - \-r Structural Manager N ENCF' 'EXPIRES.12 -31 -20131 205 SE Spokane Street Suite 200 Portland, OR 97202 PHONE 503.221.1131 FAX 503.221.1171 www.hlrpr.com Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 235 Shear walls/anchors 06/07/2013 00:00 MST2012-00302 PASS Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 245 Firewall 06/11/2013 00:00 MST2012-00302 PART Exterior 1 layer Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 910 Sprinkler rough-in/test 06/12/2013 00:00 MST2012-00302 FAIL 1. Provide correct plans for inspection. Stamped and approved plans do not show floor plan used in unit. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 210 Foundation walls 04/01/2013 11:00 MST2012-00302 PASS Erosion approved Ufer tagged Setbacks Surveyed Geo tech report Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 235 Shear walls/anchors 06/07/2013 00:00 MST2012-00302 PASS Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 240 Exterior sheathing 06/07/2013 00:00 MST2012-00302 FAIL 1. Wrap beams with straps as shown on detail S7.0 #11. Item appears on Pg S4, holdown details 6 thru 10, if applicable, or provide stamped letter from engineer of record showing detail of approved installation. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 615 Mechanical rough-in 06/13/2013 00:00 MST2012-00302 PASS NOTE Low pressure gas test to come Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 105 Underground/slab cover 04/10/2013 00:00 MST2012-00302 FAIL Electrical service conduits not complete Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 245 Firewall 06/11/2013 00:00 MST2012-00302 PART Exterior 1 layer Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 105 Underground/slab cover 04/10/2013 00:00 MST2012-00302 FAIL Electrical service conduits not complete Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 11084 SW MALLOW TER, TIGARD, OR, 97223 Residential - Master Permit 275 Framing 06/28/2013 00:00 MST2012-00302 PASS Violation Summary: Inspector Contractor p . o . STREET TREE TIGARD CERTIFICATION I, `77:0 s-cQ. , owner/agent for , (PLEASE PRINT) (PERMIT HOLDER) do hereby certiji that the following location meets City of Tigard land use and development standards for street tree installation and is consistent with the approved site plan. PERMIT NO.: VNIN S-c' 2.6 L— 60 3 02.. SI"1E ADDRESS: 6 S Li _Cup N∎AlLaw SUBDIVISION: � � e LOT#: —70 SIGNATURE: IC/-44Q,,,,` DATE:E: 9 l s f a ( AGENT) J RECEIVED & VERIFIED BY: , DA1 E: OF TIGARD) ❑ Tree location verified per /proved site plan. I:\Building\Forms\StreetTreeCertificate 05/30/2012 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: Jurisdiction: Of■q-C-2.old. -- eo1 oL 7'`c\ Site Address: \o g -"A) w`a.11 Subdivision/Lot#: -0 -u•�u�n�.. eAeex. Low' —1 and/or Map and Tax Lot #: By my signature below, I certify that a minimum of fifty (50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 Signature: 9 Date: q (�(t3 er nera Contractor/ uthorized Agent Print Name: —TOM ORSC Section N1107.2. High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting.source that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt. I:\Building\Forms'RES-HighEfficiencyLighting.doc 07/01/08 Oregon Residential,Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I, as?S.-e-Q.etr%... , am the general contractor or the owner-builder at the following address: Site Address: City: T Permit#: 1N`$T' 2.012 —a 452 a 2_. Subdivision/Lot#: jux. ■ I L —TO and/or Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: Date: c/ (- 143 G ral Contractor or Owner Builder I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08 FOR OFFICE USE ONLY - SITE ADDRESS: This form is recognized by most building departments in the Tri -County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter T I G A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard- or.gov TO: DEPT: BUILDING DIV I� DATE E D: v�D \ I I I � 5 • y `.3 FROM: �iio, (« G i 1 g T IME COMPANY: ( ,4 A,Vo# k, PHONE: Cj f - 2 127 ia ' 7/3- / 3 i(i)40 ZW- RE: /1062 / f ltr9gi{ f o ' troSt 4) kt«�t~ H517 A?? (ite ddress) 1 (Permit Number) I , 3v0 I LL ft-a := §u_gM � 'iK /�51�11 U � ' ) 50 I U 3 4 (Project name or subdivision name an lot number) << il 30 3 ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: I Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: C_.® -v\ - L& t_ hA ..)4AQA vrti,n.Q. j p-1 0 . FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: _ Fees Due: ❑ Yes ❑ No Fee Description: Amount Due: $ La J Special Instructions: Reprint Permit (per PE): ❑ Yes I o ❑ Don} Applicant Notified: Date: (,i /P1 f ( 1j. j Initials 0-k- . 1:\Building\ Forms \TransmittalLetter - Revisions.doc 05/25/2012