Certificate of Occupancy 71 a CITY OF TIGA CERTIFICATE OF OCCUPANCY
a : Permit #: MST2012 -00242
COMMUNITY DEVELOPMENT Permit Issued: 10/11/2012
T [CARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Parcel: 2S104BB09000
Jurisdiction: Tigard
Site address: 14231 SW WALNUT CREEK CT
Subdivision: WALNUT CREEK Lot: 7
Project Description: New SF
Class of Work: NEW
Type of Use: SF
Type of Constr: VB
Occupancy Group: R -3
Occupancy Load:
Fire Sprinkler Required:
Project Name: Walnut Creek, Lot 7
Owner: LEGEND HOMES CORPORATION
12755 SW 69TH AVE STE #100
TIGARD, OR 97223
Phone: 503 - 620 -8080
Contractor: LEGEND HOMES
12755 SW 69TH AVE #100
TIGARD, OR 97224
Phone: 503 - 620 -8080
Fax: 503 - 598 -8900
This Certificate issued 2/27/2013 grants occupancy of the above referenced building or portion thereof
and confirms that the building has been inspected for compliance with the 2011 State of Oregon Specialty
Codes for the group, occupancy, and use under which the referenced permit was issued.
Mark VanDomelen
Building Official
City of Tigard
POST IN CONSPICUOUS PLACE
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
SA; I, A k Sv l J V 2 r l , am the general contractor or the owner- builder
at the following address:
Site Address: I 4 3 1 i . i/ 1A( 114
City: 4Ar A
Permit #: /1,� ` T 2 2L —0o ,l
Subdivision/Lot� #/: L J 7
and/or
Map and Tax Lot #:
To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918- 480 -0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture- sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
ild
Signature: d LJ. 4114,..I Date:
Y..#2/I 3
Gen; al Co tractor or Ow ( f ilder
I:\Bui l ding\Form\RES- MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code N1107.
HIGH - EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: A e s �D t 2 _ 002,4 2 Jurisdiction: 6 � d
Site Address: 14, 2'5 1 51A,- j 1 jvi,v 3 (N&k J� O/
Subdivision/Lot l/ V � �p
#: , e�J k
and/or
Map and Tax Lot #:
By my signature below, I certify that a minimum of fifty (50) percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)
Signature: Date: 2-Z r
h
Ow r /General Contractor t • riz e Agent
Print Name: "k S 1),‘,./404
ORSC Section N1107.2. High - efficiency interior lighting systems. A minimum of fifty (50) percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent, or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw -in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent, or a minimum efficacy of 40 lumens per
input watt.
RBuilding\Forms\RES- HighEfficiencyLighting.doc 07/01/08
.71 STREET TREE
: I...
TIGARD CERTIFICATION
I, P v S v I owner/ agent for Le)&ind liesme5 ,
(PLEASE PRINT) (PERMIT HO R)
do hereby cert% that the following location meets
City of Tigard land use and development standards
for street tree installation and is consistent
with the approved site plan.
PERMIT NO.: M5 T--- 20 t2- on 24 2
ST1 E ADDRESS: 1 + 2� ) w W / /I (
SUBDIVISION: _ i LOT #: 7
_ _
SIGNATURE: / 1 .. L � i _ DATE: E: - Z) 1 3
(OWN :�7/AGENT)
RECEIVED & •
VERIFIED BY. DA'11J:
(CITY OF 17GARD)
❑ Tree location verified per approved site plan.
I:\ Building \Forms \StreetTreeCertificate 05/30/2012
Mark Sullivan
From: GLENN C WAER [gbopwaer @msn.com]
Sent: Thursday, February 21, 2013 6:09 PM
To: Mark Sullivan; Mike Goodrich; Carol Eisenlohr
Subject: WC L -7 final inspection
Inspection Date: 2/21/13
Project Address: 14231 SW Walnut Creek Way
Energy Path: ETO
Path measures: Pass
Duct test: Pass
Maximum CFM allowed: 109
Test results: 65
Thermal Enclosure Check list: Pass
Blower Door test: Pass
Maximum ACH allowed: 5
Test results: 4.7
Re- inspection required: NO
Action required: None - House certified
Thanks
Glenn
Glenn Waer Energy Consulting
dba Willowaer
16266 Hiram Ave
Oregon City, OR 97045
503 - 701 -3165
1