Permit CITY OF TIGARD MECHANICAL PERMIT up P ` COMMUNITY DEVELOPMENT Permit #: MEC2013 00091 T FGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 02/12/2013 Parcel: 2S102DA00401 Jurisdiction: Tigard Site address: 13125 SW HALL BLVD PERMITS Project: City of Tigard Subdivision: BARNUM PARK Lot: 9 Project Description: Adding air distribution w /control damper T stat to new private office Contractor: REITMEIER MECHANICAL Owner: TIGARD, CITY OF 19570 SW 90TH CT 13125 SW HALL TUALATIN, OR 97062 TIGARD, OR 97223 PHONE: 503 - 603 -0205 PHONE: FAX: 503 - 603 -0150 • FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 02/12/2013 $112.04 Class of Work: ALT Type of Const: Plan Review 02/12/2013 $28.01 Occupancy Grp: Occupancy Load: 12% State Surcharge - Mechanical 02/12/2013 $13.44 Stories: 1 Info Process /Archiving - Sm $0.50 (up to 02/12/2013 $2.00 11x17) Project Valuation: $1,900.00 ' Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: • Vents w/o Appliances: 50 or Greater HP: Air Conditioning: - . Heat Pump: Appliances Vent Fans: Vent Systems: Total $155.49 Hoods: Comm Incinerators: - Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: • Duct Work: Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: ^��� %` // 6121 / 1 Permittee Signature: /� L /�Iv/�� -��1� cr , i �y (� C ��jr Call 503.639.4175 by 7 :00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application g�� FOR OFFICE USE ONLY . City of Tigard RECEIVED D Receivea 'gyp Date /By: - I I �� Permit No.:LA EG9.42) 3 - 0(20 13125 SW Hall Blvd., Tigard. OR 97223 Plan Review t -' '-'_ Phone: 503.718.2439 Fax: 503.598.196 Other Permit: Ins Inspection Linc: 503.639.4175 `� 12 2013 Date/By: &p,w/ 3' - 0003 Tt ti ALtlt p Date Ready /By: Juris: 0 See Page 2 for Internet. www.tigard or.gov Notified /Method: ; 1C, Supplemental Information CITY OF TIGARD TYPE o ?,14bING DIVISION COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction ddition /alteration /replacement performed. Indicate the value (rounded to the nearest dollar) of all El Demolition El Other: mechanical materials, equipment, labor, overhead, and profit. Value: $ NCO CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES* El 1- and 2- family dwelling Commercial /industrial El Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating /cooling: Air conditioning Job site address: I'i 25" S,.,..) \-kisnti (requires site plan showing placement) 46.75 Furnace 100,000 BTU (ducts /vents) 46.75 City /State /ZIP: T\ ( fs -Q.-V a- G { 1 Z V'S Furnace 100,000+ BTU (ducts /vents) 54.91 Suite /bldg. /apt. no.: I Project name: • 7 L Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended. etc. 46.75 Subdivision: Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 r Gas fireplace /insert 33.39 N 4 k - �X (;-1 NAL- � 't 'ST �t.%V r1 O ^ 3 " C-O Flue vent for water heater or gas - kvtiQ ti • ; STA.--r- ,Co � fireplace 23.32 MCA^' Log lighter (gas) 23.32 Qil \ 0 RCe" arYxC -e Wood /pellet stove 33.39 Wood fireplace /insert 23.32 ❑ PROPERTY OWNER I ❑ TENANT Chimney/liner/flue/vent 23.32 Other: 23.32 Name: �.`''\ op, Z ( . 71 . 01: Environmental exhaust and ventilation: Address: Range hood/other kitchen equipment 33.39 City /State /ZIP: Clothes dryer exhaust 33.39 Singlc -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 23.32 El APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 23.32 Business name: ;l vtul __ A4 N -� t' Other: 23.32 '_ "� Fuel piping: Contact name. o . _ er � - ,p�e..1�v $14.15 for first four; $4.03 for each additional Address: t 50 qdl�- CaJv,( Fumacc, etc. I Gas heat pump City /State /ZIP: Totirit 04 0 170(, L No <' Wall /suspended/unit heater i Phone: (i g3 C cn J " c ! Fax: : ( 5�1) ( t Water heater ��"� " - & r Fireplace E -mail: f v - LID / c .6 vt"�,. P.,✓ Vv�X41 n.. CD'^i Range 1 C CONTRACTOR Barbecue Business name: See Clothes dryer (gas) Other: Address: MECHANICAL PERMIT FEES* City /State /ZIP: Subtotal Phone: ( ) Fax: ( ) Minimum permit fee ($90.00) Plan review (25% of permit fee) CCB lie.: 1537'7 o State surcharge (12% of permit fee) TOTAL PERMIT FEE i S� 4 k Authorized signature' / f --c--G--- This permit application expires if a permit is not obtained within 180 //�� days after it has been accepted as complete. Print name: /2 ro , ( ^ ' _ • � Lr �� ,p� Date: Z. /2 /3 * Fec methodology set by Tri- County Building Industry Service Board 1: \Building \Permits \ MEC- PermitApp doc 0 440 -4617T (I1 /02 /COWWEB) RECEIVED FEB 1 2 2013 CITY OFTIGARD BUILDING DIVISION Exist. Ext. Walls /// t _ ExisTtn., 14 s/A Data i Co ;1 $ oa� e ., [116 s T c frt I Exist. GLB -._- Exisz 1 N /4" �A Doc F� la x 0 `` , Exist. 6x6 Col. t/te m WI. 1. w/te m p. Frtn. w /aµ GI. w /tep. G1, New Box Col. to match Exist. r 0. .. ,i * New Walls - _Bop Z013 •- 0O013 3 -5/W' Mtl. Studs @ 24 "oc - 10 -ft. Ht. 5/8" Type'X' Gyp. Ea. Side - fire block @ ceiling or as req. 0 FLOOR PLAN SCALE: 1 /4" = 1'-0" NEW PRIVATE OFFICE - City of Tigard 1 -1 1 -1 3 Centrex Construction 8250 SW Hunziker Rd., Tigard, OR 97223 ph 503 - 684 -0443 Johnson ' /;(� FEB 12 2013 Code No. LIT - 1900616 Controls November 13, 2009 CRS! OF-TIGARD T600xxx -4 and T600xxx -4 +PIR Series BUILDING DIVISION Thermostat Controllers Description -- — The T600xxN -4 and T600xxN -4 +PIR Series , Controls 0Jf gib gib Non - programmable and T600xxP -4 and Co /_ T600xxP -4 +PIR Series Programmable Thermostat Controllers are specifically designed for control of single- stage, multi- stage, and heat pump commercial heating and cooling equipment. The T600xxP -4 and T600xxP -4 +PIR Series Thermostat Controllers are also specifically designed for control of rooftop units (with and RoamTema . RootaTemP without economizers). 68,0 °F 68.0 °F The T600xxx -4 +PIR Series Thermostat ( t!) - ` r,c,� (.7.)L.4) 0 II ll ��,.,��I"l Controllers have occupancy sensing capability \ \� U `/ u built into the device. These are stand -alone devices that maximize up to 30% energy savings in high- energy usage light commercial T600xxx -4 and T600xxx -4 +PIR Series Thermostat Controllers buildings, such as schools and hotels, during occupied times by using additional setpoint strategies. • t wo configurable digital inputs — provide Features g g p P The T600xxx -4 and T600xxx -4 +PIR Series additional inputs for advanced functions • Thermostat Controllers provide exceptional onboard occupancy sensor (Passive such as remote night setback, occupancy temperature control in an easy -to -use and Infrared [PIR] Models) — provides energy override, and service or filter alarms flexible package. All models have over savings without additional installation • over 20 configurable parameters – enable time /cost 20 configurable parameters, enabling the the thermostat controller to adapt to any thermostat controllers to adapt to a variety of Password protection option — protects application, allowing installer parameter applications. against undesired thermostat controller access without opening the cover tampering The T600xxx -4 and T600xxx -4 +PIR Series • backlit Liquid Crystal Display (LCD) — • configurable auxiliary output — provides Thermostat Controllers include several offers real -time control status of the 24 VAC control for exhaust fans, lighting, T600HCx -4 and and other auxiliary functions models: single-stage (T600HCx-4 environment in easy -to -read, English plain T T600HCx -4 +PIR Series), heat pump text messages with constant backlight that economizer output (600MEP -4 and T600MEP -4 +PIR models) — controls (T600HPx-4 and T600HPx -4 +PIR Series), ) ( ) brightens during user interaction multi -stage (T600MSx -4 and T600MSx -4 +PIR • simplified setpoint adjustment — enables economizer operation for single- and Series), and economizer (T600MEP -4 and the user to change the setpoint by simply multi -stage unitary rooftop equipment T600MEP -4 +PIR). All models employ a pressing the UP /DOWN arrow keys Repair Information unique, Proportional- Integral (PI) p • five easy -to -use interface keys — allow for time - proportioning algorithm that virtually If either the T600xxx -4 or T600xxx -4 +PIR eliminates temperature offset associated with easy commissioning and adjustment of the Series Thermostat Controller fails to operate traditional, differential -based thermostat thermostat controller and eliminates the within its specifications, replace the unit. For a controllers. need for DIP switches replacement thermostat controller, contact the • three Light- Emitting Diodes (LEDs) — nearest Johnson Controls® representative. Refer to the T600xxx -4 and T600xxx -4 +PIR provide fan, heating, and cooling status at P Series Thermostat Controllers Product Bulletin a glance (LIT- 12011583) for important product application information. Accessories Code Number Description SEN - 600 - Remote Inside Air Temperature Sensor SEN -600 -4 Remote Inside Air Temperature Sensor with Occupancy Override and LED TE-6361M-11 Duct Mount Air Temperature Sensor TE - 6363P - Outside Air Temperature Sensor TEC- 3 -PIR2 Cover with Occupancy Sensor 1. Additional TE- 63xx -x Series 10k ohm Johnson Controls Type II Thermistor Sensors are available; refer to the TE -6300 Series Temperature Sensors Product Bulletin (LIT - 216320) for more details. When a TE- 63xx -x Series Sensor is installed according to remote sensing wiring, the thermostat controller controls based off the temperature sensed by the TE- 63xx -x Series Sensor. 2. The TEC -3 -PIR Accessory Cover can be used to replace the existing cover on a non -PIR T600xxx -4 Series Thermostat Controller to provide occupancy sensing capability. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2012 Johnson Controls, Inc. www.johnsoncontrols.com 1 of 3 NFB24, NFB24 - NFX2 NFX24 - On /Off, Spring Return, 24 V BELT MO • Torque min. 90 in for control of air dampers � t1 Application •; For On/Off, fail -safe control of dampers in HVAC systems. Actuator sizing should be ° `F: • done in accordance with the damper manufacturer's specifications. Control is On /Off from an auxiliary contact, or a manual switch. I The actuator is mounted directly to a damper shaft up to 1.05" in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. 111 • ii Operation 5 The NFB and NFX series actuators provide true spring return operation for reliable fail safe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the WARRANTY actuator. The NFB and NFX series provides 95° of rotation and is provided with a graduated Yi os 1 position indicator showing 0° to 95 °. C E TEMP,0,0.9 a U� °S ERG. EQUIP. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. Technical Data NFB24, NFB24 - S, NFX24, NFX24 - S Power supply 24 VAC ± 20 % 50/60 Hz The NFB24 -S and NFX24 -S versions are provided with two built -in auxiliary switches. 24 VDC +20% / 10 °/a These SPDT switches are provided for safety interfacing or signaling, for example, for fan start-up. The switching function at the fail -safe position is fixed at +10 °, the other Power consumption running 6 W switch function is adjustable between +10° to +90 °. The NFB24, NFB24 -S, NFX24 holding 2.5 W and NFX24 -S actuator is shipped at +5° (5° from full fail -safe) to provide automatic Transformer sizing 8.5 VA (class 2 power source) compression against damper gaskets for tight shut -off. Electrical connection NFB24... 3 ft, 18 GA appliance cable, 1/2" conduit connector Dimensions (Inches [mm]) -S models: two 3 ft, 18 gauge appliance cables E with 1/2" conduit connectors Ic -2 (supplied) z NFX24... 3 ft [1m], 10 ft [3m] or 16 ft [5m] 18 GA 0 1/2' Centered 3/4' Centered 1.05' Centered La appliance or plenum cables, with or without 1/2" (Default) (Field Selectable) (Field Selectable) 3 conduit connector -S models: two 3 ft [1m], 10 ft [3m] or 16 ft [5m] appliance cables, with or without 1/2" conduit connectors m o .I Overload protection electronic throughout 0 to 95° rotation ''I Control on /off II� 111 ��I I/ Torque 90 in -lb [10 Nm] minimum IIINIII Direction of rotation spring reversible with CW /CCW mounting — II� 11 Mechanical angle of rotation 95° (adjustable with mechanical end stop, 35° to _ — -- 95 °) ∎ o - Ta 969 246 Running time motor < 75 seconds 2 31 [58.78] 5.31 [1350 spring 20 seconds CP -4 °F to 122 °F [ -20 °C to 50 °C]; E < 60 seconds 0 -22 °F [ -30 °C] �, �� o Po indication visual indicator, 0° to 95° rImdtb > �t „II III I I I■ 026 65 0 IIIIIIII■ . _ ,mu eri (0° is full spring return position) ti; 0 - -- Manual override 5 mm hex crank ( Allen), supplied I lair � % ' IMF rr �i�r ° Humidity max. 95 %RHnon-condensing ` � II�I�II�I�_ m Ambient temperature -22 °F to 122 °F [ -30 °C to 50 °C] v i • ® IIIIIIII 1 IU • Storage temperature -40 °F to 176 °F [ -40 °C to 80 °C] � •i `' Housing Nema 2, IP54, Enclosure Type2 03e 93 0 Housing material zinc coated metal and plastic casing 125 [3 o Agency listings t cULus acc. to UL60730 1A/ 2 14, o CAN /CSA E60730 -1:02, CE acc. to 2 i 004/108/EC & 2006/95/EC Noise level <50dB(A) motor © 75 seconds 562dB(A) spring return Servicing maintenance free Quality standard ISO 9001 Weight 4.15 lbs (1.9 kg); 4.4 lbs (2.0 kg) with switches t Rated Impulse Voltage 800V, Type of action 1.M (1,AA.B for -S version), Control Pollution Degree 3. NFB24 S NFX24 -5 Auxiliary switches 12 x SPDT 3A (0.5A) ® 250 VAC, UL approved one set at +10 °, one adjustable 10° to 90° 800 -543 -9038 USA 866- 805 -7089 CANADA 203- 791 -8396 LATIN AMERICA 67 Johnson �J)) Code No. LIT - 1923150 Controls : Issued February 25, 2010 RD -2000 Round Control Dampers Description Johnson Controls provides top - quality, low- leakage RD -2000 Round Control Dampers for use in Heating, Ventilating, and Air '"•�. Conditioning (HVAC) systems that fit your size and application requirements. Round dampers are available with seals for low- leakage control dampers and are easily installed in round / " ducts. Round dampers are available with or without a factory- installed actuator. 1 �� Features • Formed shroud \ e • Available factory- installed actuator • One -piece construction Applications ° Furnish and install round control dampers manufactured by Johnson Controls. Damper shrouds are to be constructed of formed 20 -gauge RD -2000 Round Control Dampers galvanized steel, mechanically joined. Blade rotation shall not exceed 80 degrees. Damper blades are to be constructed with 1 -piece or 2 -piece Repair Information 16 -gauge or 20 -gauge galvanized steel, determined by size. If the RD -2000 Round Control Damper fails to operate within its specifications, replace the unit. For a replacement RD -2000 Damper performance shall be designed for tight shutoff. Damper, contact the nearest Johnson Controls® Leakage rating at 4 in. Water Gauge (w.g.) differential pressure representative. with 5 Ib•in. /sq ft closing torque shall not exceed 10 cfm per square foot. Dampers without actuators must be rated to operate over a temperature range of -20 to 200 °F ( -29 to 93 °C). Damper sizing shall be by the designer in accordance with accepted industry practices to ensure proper system performance. Factory- installed electric and pneumatic actuators are available. Selection Chart Not all combinations are available, check the selector tool software application for valid combinations. Code Number R C G d d NC Product Family R = Round dampers Application B = Balancing (no seals) C = Control (Class II) L = Low Leakage Control (Class I) Shroud Type A = Aluminum (Class I only) G = Galvanized steel S = Stainless steel (304) Diameter 4 to 24 in., 1 in. increments Actuators B = Bracket with no actuator E = Electric non- spring return M = Manual locking quadrant N = None P = Pneumatic, D -3062 S = Spring return electric Control Signal B = Floating with two Single -Pole Double -throw (SPDT) auxiliary switches E = Proportional with two SPDT auxiliary switches P = 8 -13 lb spring range Operation NC = Normally Closed NO = Normally Open 1. Based on torque requirements, RCG construction dampers use M9106 or M9206 actuators on all sizes, and RLG construction dampers use M9210 and M9220 actuators on all sizes. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2010 Johnson Controls, Inc. www.johnsoncontrols.com 1 of 2