The plans for the project have been reviewed for conformity to applicable codes.
Please submit the following items for review and completion of the plan review
process.
ACCESSIBILITY
All areas and facilities shall be accessible to persons with disabilities (OSSC.
Chapter 31].
1✓ The exit pathway between the district secretary area and the corridor exit
shall not be less than 42• wide (ADAAG 25C). The floor plan measures 30°
wide' PRA t) P) 1_I 7
' 5 •
A : Al]. doors with controls and i'
hardware shall be of the type providing
/iceo irS accessibility to persons with disabilities (Section 3109 (c)]. Hardware on
doors shall have lever or other shape not requiring tight grasping.
F}AW1l•AWdri$ pinching, or twisting to operate. Controls shall require a force no
Ms greater than 5 pounds- -force to activate (Section 3109 (c)].
3 The thermostats shall be located above the finish floor within the reach
range of Section 3109 (b) E or F. pley)a6 11E04 )JO7E d 1 MIDI
/ Provide cross sections of counters and work stations having the reach
I L. ranges as specified in Section 3109 (b) 3a. Counter tops and sinks shall
Iii no higher than .34° 'above finish - _floor, have knee clearance and ional provision
additional s ecified i Section 3109 K 2 & 3.
L I )9e lj FIRS Aria LIPg QTY K.ITG STYLE SI 4 CLI NE r' TC4)
1. I am unable to determine the exiting for the employee lounge. Provide a
1. floor plan of the exit way and the exiting system it terminates
into.
i
a. The exit way must be constructed to
one -hour fire resistive
corridorconatruction. N1 WIT . ribs NoT
b. Walls of a corridor and its celiling must be of not less than one -
hour fire - resistive construction with all openings and penetrations
protected (Section 3305(g)).
c. Protection of corridor walls and ceilings shall include the
following (Sections 4304, 4305 and 43061:
1. Fire dampers for heat duct penetrations.
- 2. Canopies for recessed light fixtures.
3. Metal pipe extensions for plumbing penetrations.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
d5 08:47 WU:, 884 %L97 C:i"il Ur iikyARD 1pjuUt/Uuk
6 .6" -
Kim I. Prucunier RA
June 23, 1995
Page 2
/,
,! 7 All doorways penetrating the one hour fire- resistive corridor
construction shall be protected by a tight - fitting smoke and draft
control assembly having a 20- minute fire - protection rating [Section
3305 (H)]. Doors shall be self- closing or automatic - closing (Section
4306 (f)].
2. When the occupant load of the corridor reaches 50, the corridor shall lead
V to 2 separate exiting systems (Section 3305 (e)].
3. The exiting system within the proposed remodel area shall enter into a one
hour fire resistive corridor providing not less than two directions from
any point within the corridor to separate exits.
W 4. Provide exit illumination within the corridor and the executive lounge.
5. Provide a larger scope floor plan showing the exiting from the stairway at
the first floor and the second floor at the opposite end of the area
designated corridor.
cAZ Provide 2A -103C fire extinguishers mounted throughout at a travel distance
not exceeding 75*. Awr�•_�1l 1
CAL ��1�V� 1V
F AUX
Supply air and return air ducting into the fire rated corridors shall be
protected with fire dampers [Section 4305 (b)]. 100 O '1 9I)
PLUMBING GAM. f to ea JPO.
1. Provide three copies of the Plumbing Plan. A separate permit process is
required.
SPRZNXLEA
1. Provide three copies of the sprinkler system modification plan with
hydraulic calculations. A separate permit process is _ reu ��R
required.
��
edd. work
This plan review does not include electrical. `�
•
Please make these corrections and additions to the appropriate pages of the
drawings and submit 3 copies of the revised plans. If you need to discuss any of
these requirements, please do not hesitate to call.
Sinc rely, .
C.
James Funk
Plans Examiner
JF:jr
c: Washington Square Inc.
700 Fifth Ave., #2600
Seattle, WA 98104 -5026
wcruwZMuPLS -42c.o e
r 1
a3eS
June 07,1995
Mr. Jim Funk
Building Inspector
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223
RE: Mervyn's, Washington Square Mall
Dear Mr. Funk,
Enclosed please find four sets of prints and specifications for the tenant improvements at the
Mervyn's store at Washington Square Mall. As we discussed on the phone an architectural firm
sealing drawings in the state of Oregon has to operate as a Professional Corporation registered in the
state. The same is not true for a Professional Engineer. He needs only be registered as a P. E. to
legally seal the documents.
Please accept the enclosed documents to fulfill the legal permit requirements. They are sealed by a
P. E. registered in the state and have not been altered since our previous submittal. It is SSOE's
intention that these documents may be substituted for the documents originally submitted on May
17,1995.
If you have any further questions or concerns, please call.
Thank you,
SSOE Inc.
• :
J r
Kim L. Procu •er R.A.
Project Manager
cc: 946039 -00 /file
Dick Canfield
Ken Hanson
Pam Quinn (Mervyn's)
SSOE, INC ARCHITECTS ENGINEERS
1050 Wilshire Drive • Suite 260 • Troy, Michigan 48084 • 810 - 643 -6222 • Fax 810 -643 -6225
TOLEDO OH • FLINT, MI • TROY, MI • NASHVILLE, TN • BELLEVUE, WA
t , ,wo 75- al' 2-24
MEMORANDUM
CITY OF TIGARD, OREGON
TO: Jim Funk
FROM: Michael Rudd
DATE: June 21, 1995
SUBJECT: Mervyn's
Washington Square
The remodel or tenant improvement for Mervyn's will not require
electrical plan review.
From: FINANCE /JIM
Subject: Re:mervyn's fire dept copy, do not have skip it
To: JEANNE
X -To: FINANCE /JEANNE
Date: 1 Aug 95 08:03:45
From: FINANCE /JEANNE
Subject: To: JIM
X -To: JIM
Date: 31 Jul 95 15:19:40
NEED A FIRE DEPT COPY OF PLANS FOR MERVYN'S BUP95 -0224
THANKS ZOO w S C2 . .