Loading...
Report Carlson Geotec _111Cal Mafn Box Salem Office Bend Office P.O.BoX 23814 4060 Hudson Ave., NE P.O. Box 7918 A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Phone (503) 684 -3460 Phone (503) 589.1252 Phone 541 GeOtechnical Consulting ( ) ( ) 330 -9155 Construction Inspection and Related Tests FAX (503) 870.9147 FAX (503) 589 -1309 FAX (541) 330-9163 CGT No: G0602953.A 8 -, 0000 ( + � 7 —) I 'i FIELD REPORT DATE COVERED: April 28, 2008 PROJECT: TVFR Fire Station 50 "Walnut" ADDRESS: / 2 ( /',� .1258b -3W Walnut Street, Tigard, Oregon:. ~ ` BY: M. David Irish ()Ai WEATHER: Cloudy, -60 °F PURPOSE OF VISIT: Subgrade & Proof -Roll Observation Carlson Geotechnical (CGT) staff, David Irish, arrived on site at about 10:55 a.m. at the request of Matt with DBEC Excavation & Construction (DBEC). The purpose of my visit was to observe the exposed subgrade soils on a portion of the site. I met with Rick, with DBEC, at the site. Proof -roll Observation: Today I observed a proof -roll of the parking area at the north end of the proposed fire station. The approximate area proof - rolled today is marked out on the attached site plan (elevations were provided by DBEC). Rick informed me that there was approximately 2.5 feet of fill (1 - minus crushed rock from Cobb Rock Products) to be placed within the area proof - rolled to reach finished elevations. The proof -roll test was performed using a fully loaded, dual axle, dump truck and revealed areas of minor pumping and rutting as the tires of the dump truck passed over the fill. I informed Rick of my observations and that I observed the fill to be below optimum moisture for compaction. I recommended that the fill be watered down and recompacted. I informed Rick that no more fill should be placed within the area indicated until another proof -roll test could be observed by CGT personnel. Rick indicated that he understood and agreed with my recommendations. Based on my observations the area proof - rolled today has not been prepared in general conditions with CGT recommendations and additional proof -roll testing will be necessary. Subgrade Observation: I observed the DBEC crew excavate the southwest corner for the proposed fire station building. The area observed measured approximately 28 feet (east -west) by 38 feet (north- south). Most of the area was over - excavated 4- inches to allow for a minimum 16 -inch rock section. The only exception was the northwest corner of the area, which was over - excavated approximately 2 feet to remove large tree roots. The area that was over - excavated approximately 2 feet measured approximately 10 feet by 10 feet. The exposed subgrade soils consisted mainly of native, brown, moist, silt. Probing the exposed subgrade soils with a 1/2-inch-diameter soil probe and using moderate effort, I was generally able to penetrate the exposed subgrade soils 8 to 10 inches, indicating soft soil conditions. While on -site, Rick brought to my attention that the basement of the previously existing residential structure located on the site had been backfilled prior to the DBEC crew's arrival on- site. I observed that the basement excavation was located within the southwest corner of the proposed parking area and measured approximately 20 feet (east -west) by 40 feet (north - south). Pot - holing through the center of the backfilled excavation revealed that the excavation TVFR Fire Station 50 'Walnut' Tigard, Oregon CG Project No. G0602953.A April 28. 2008 was approximately 4 feet in depth and had been backfilled with crushed rock and sand and that construction debris (concrete and brick) was still present at the bottom of the excavation. I recommended to Rick that the undocumented fill be removed from the excavation and that the excavation be backfilled with structural fill. Rick indicated that he understood and agreed with my recommendations. Based on my observations the subgrade soils observed within the southwest corner of the proposed building have been prepared in general conditions with CGT recommendations. I left the site at about 12:15 p.m. Should you have any questions regarding this report, please contact us at (503) 601 -8250. Respectfully submitted; Carlson Geotechnical M. David Irish yan T. Houser, CEG Senior Engineering Assistant Senior Engineering Geologist Note: Our reports pertain to the locations observed at the time of our visit only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. ATTACHMENTS: Site Plan (1 page) DISTRIBUTION: Mr. Gary Wells, TVFR, FAX: 503.642.9655 Daniel Watkins, City of Tigard Building Department, FAX: 503.624.3681 Lance Cerny, Lewis & Van Vleet, FAX: 503.885.1206 Jeff Bringenberg, Peck Smiley Ettlin Architects, FAX: 503.248.0223 Michael Krecklow, First Cascade Corporation, FAX: Kendra Laminack, PBS Environmental, FAX 360.696.9064 Matt, DBEC Excavation & Construction, FAX: 503.513.6254 WALNUT STREET FIRE STATION - TIGARD, OREGON SITE PLAN • f ;4 i w ` . P o . + •.. . + f . • • . ••• +d j O < ••� ` ta.: _ ••• Se ' I . ; . d . t, < _ +. 1111111111:1•• :.:. S + . e' •- a • :-..-4- 1 01 ' :IA. . *IV ■ :- - ',4g.:-.. •••._ s ....• • ". - 4 . - • . NIPS • :•,_ ■ • . . ,' " .- i• -''77 • Z\ :" 46. ! ;••34`.---;-- : - • , • • • ::: ::•: :1A- ::- T.:-4. : ' • l ' i -Z . : ; sy".•'-.:•,t• -- . 01 % ` .: •. + mil[• .'` •• •+ ' • : ' • • • 11'D co • k • • :: . :...•• /•/ nYiji auW4 • tL 4' : ; ' + • . d • .." ' • ' l !''. 1 ' • ., • ' •5::::::0 :14irNItlilirli., lim i _ Aim...........:4;60 .- -" • . • -•• ■,. 4. ' .•:;.••• ■ i' ., t . 4 , e .....---- . .. 11..L - :. I P ' . ' "., 4 • '• • ? 4' ".. ;gil : ! 1 I ' KII-wile i mi _______.„. .• . ..t.p.., * .,..:.....:.• ":.. . •• .. -• , 0 : _,,r . �O � .. Q � `s�_r -3 ..‘ . 1.• • - i -41. 7 . ....,./r-.. . .,..-, N .....: ., . ..... --. : . . i . . 2.,.... ...i . . , . : ,,...... ........> :,.......\ . .. . ....... . .ter • DATE COVERED: .......-•-• . q.18,,,oy < - „w . •.•hin. r r NOTES: LEGEND Drawing based on approved construction CGT Job No. drawings. G0602953.A , Approximate Scale i inch = 40 feet Gp►R 0p Carlson Geotechnical INMEINEMIE Construction P.O. Box 23814 UMMENIMENNEMII. Observation ° 503.60i4250 ` Tigard, Oregon 97281 0 40 80 • Plan