Report (4) • • � 110 Main Office Salem Office Bend Office P.O. • Box 23814 �J60 Hudson Ave., -NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carls•pn e� C t 141(� �1►1 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 iY i 110. FAX (503) 684 0954 FAX (503) 589 1309 FAX (541) 330 -9163 - December 16, 2008 T0806977 Permit No. BUP2008 -00022 • FIELD INSPECTION REPORT • DATES COVERED: December 5, 2008 PROJECT: Tualatin Valley Fire & Rescue - Fire Station #50 • ADDRESS: 12617 SW Walnut Street - Tigard, OR INSPECTOR: J.P. Haynes - COP #864, OBOA #792, ACI #1087712, ICC #5309887- 86/ -84 12 -05 -08 - Concrete 1 As requested by Matt with First Cascade Corporation, CTI representative was on site and performed required inspections /tests. • Cemex mix #13082 was used - approximately 30 Yds were placed on this day. Approved work/concrete poured at "west approach" to fire station. CTI representative noted, per conversation with First Cascade representative "Matt ", #4 rebar placed at 24" min for entire site. No detail observed. • Slum. 5" Air 5.6% Conc Temp 58 °F • Amb Temp 42 °F * ** CHECK ONE BOX ONLY * ** YES NO 1. This is a preliminary inspection only. — OR — ❑ 2. The work inspected conforms to acceptance criteria listed above. If "No," the portions of the work that are non - conforming items are clearly stated above and will be added to the NCL. ® ❑ Remaining portions of the work, which are not preliminary in nature, are to be considered as conforming. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectf y submitted, CARLS• TESTING, INC. Jame . Hietpas Pr Manager /ck I: Tualatin Valley Fire & Rescue — Gary Wells City of Tigard Building Division Lewis & Van Vleet Inc — Lance Cerny Peck Smiley Ettlin Architects — Jeff Bringenberg jef f@psearch5; ( 01 First Cascade Corporation — Michael Krecklow nn chaelk @firstcascade con, First Cascade Corporation — Matt Hubei matth @firstcascade.com 12 -05 -08 fr doc Main Office Salem Office Bend Office • P.O. Box 23814 ,0 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 FAX (503) 589 -1309 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (541) 330 -9163 • . December 29, 2008 T0806977 Permit No. BUP2008 -00022 FIELD INSPECTION REPORT DATES COVERED: November 6, 2008 PROJECT: Tualatin Valley Fire •& Rescue - Fire Station #50 ADDRESS: 12617 SW Walnut Street - Tigard, OR INSPECTOR: Jim Hietpas, Sr. CTI is removing the low break NCL for the above - mentioned project. Concrete has been removed and replaced. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. • Respectfully .ubmitted, • CARLSO TESTING, INC. • i J - F. Hietpas P 4ect Manager . H /ks cc: Tualatin Valley Fire & Rescue - Gary Wells City of Tigard Building Division Lewis & Van Vleet Inc - Lance Cerny Peck Smiley Ettlin Architects - Jeff Bringenberg• jeff@psearchs.com First Cascade Corporation - Michael Krecklow mi chael k @fi rstcascade . com First Cascade Corporation - Matt Hubei matth @firstcascade.com Template T0806977 Iemnl llmfd • • Carlson Testing, Inc. • NCL of Low Compressive Strength Tests & Compaction Tests Dec 29, 2008 • T0806977. Project Name: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Project Address: 12617 SW WALNUT STREET TIGARD OR Permit No: BUP2008 -00022 P.O. No: Project Manager: JAMES F. HIETPAS Compliance CTI Sign -Off Date Corrected Sample Type Register # Date Molded Date Tested Set # Days PSI Strength Req CONCRETE FOR THIS POUR JAMES F. HIETPAS 11/06/200,, HAS BEEN REMOVED AND Concrete 88015 11/06/2008 12/04/2008 28 1530 3000 REPLACED. Concrete 88015 11706/2008 12/04/2008 28 1440 3000 Concrete 88015 11/06/2008 12/04/2008 28 1700 3000 • Average f'c @ 28 days 1556 Location: EAST APPROACH • CC:TUALATIN VALLEY FIRE & RESCUE - GARY WELLS CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY CARLSON GEOTECHNICAL - RYAN HOUSER PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG FIRST CASCADE CORPORATION - MICHAEL KRECKLOW FIRST CASCADE CORPORATION - MATT HUBEL Page: 1 ¢¢ o Inc. :onstruction I & Related Tests Carlson Testing nc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone(503)684 -3460 Phone(503)589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS • Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 •Date Molded: 12/10/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: ARRIETA' S CONCRETE Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 6573 Load #: 1 Ticket#: 22 9 417 86 Weather: OVERCAST Test Time: 8 : 15 AM Air Temp. at Sampling Time: 4 2 Cylinders were cast for the following locations: Total Concrete Placement Location: . REPLACEMENT APPROACH, EAST SIDE Strength Requirement: 3000 psi fc @ 28 Days Slump: 5.000" % Air: 5. 20% Mix Number: 1308248 Conc. Temp: 56 Cement Type: 1/II Max Agg• 3/ 4 Admix/Amt: HOT WATER, • WINTERSET Cubic Yards: 10 Register Number: 0088832 Lab Location: TIGARD Set Test @ Date Test Total Unit Type Of Tested No. Days Rec'd Date Load Area PSI Fracture By I 7 12/11/2008 12/17/2008 42128 12.49 3370 2 RH2 28 12/11/2008 01/07/2009 28 12/11/2008 01/07/2009 28 12/11/2008 01/07/2009 El Distribute attachments. Average f c@ 28 days Please see reverse side for additional information. Job Number: T0806977. Register Number: 0088832 Date Molded: 12/10/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 < l in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps. no well- defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly 2nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By Ty Toiler On 12/18/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • _onstruction Inspections & Related Tests Carlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 • Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 . ' Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/21/2008 Job Number: T0806977. Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast By: J. HIETPAS JR. Concrete Supplier: CEMEX Truck #: 6071 Load #: 1 Ticket#: 10193564 Weather: PARTLY CLOUDY Test Time: 8 : 10 AM Air Temp. at Sampling Time: 50 Cylinders were cast for the following locations: MID POINT Total Concrete Placement Location: SLAB ON GRADE BEHIND FIRE HOUSE Strength Requirement: 3000 psi f c 28 Days Slump: 5.000" % Air: 5.4 0% Mix Number: 1308248 Conc. Temp: 63 Cement Type: I Max Agg: PER GRAVEL Admix/Amt: DARASET = 29 OZ, WRDA64 = 122 OZ 10/40 + — Cubic Yards: Register Number: 0088421 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 11/24/2008 11/28/2008 39612 12.49 3170 3 RH2 28 11/24/2008 12/19/2008 55600 12.50 4450 2 AF 28 11/24/2008 12/19/2008 57000 12.50 4560 2 AF 28 11/24/2008 12/19/2008 56600 12.50 4530 3 AF ❑ Distribute attachments. Average Cc @ 28 days 4 510 Please see reverse side for additional information. Job Number: T0806977 . Register Number: 0088421 Date Molded: 11/21/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 —* < 1 in. [25 nun] Type l Type 2 Type 3 Reasonable well - formed Well - Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than I in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends: tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Tolle On 1 2/29/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. :onstruction Inspections & Related Tests C arlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard. Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 ' Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 • REPORT OF 9 X 8 CONCRETE TEST SPECIMENS • Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/24/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETAS • Cast By: J. HIETPAS JR. Concrete Supplier: CEMEX Truck #: 6070 Load #: 1 Ticket#: 10193579 Weather: CLEAR Test Time: 7 : 10 AM Air Temp. at Sampling Time: 30 Cylinders were cast for the following locations: MID POINT OF LOAD . Total Concrete Placement Location: DRIVEWAY BEHIND BUILDING LEADING OUT TO WEST ENTRANCE (NO GRID LINES) Strength Requirement: 3000 psi f' c @ 28 Days Slump: 5.500" % Air: 4 . 80% Mix Number: 1308298 Conc. Temp: 60 Cement Type: I Max Agg: PER GRAVEL Admix/Amt: DARA1000 = 30 OZ, WRDA64 = 198 OZ 10/200 +- Cubic Yards: Register Number: 0088504 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 . 11/25/2008 12/01/2008 33370 12.56 2660 2 RH2 28 11/25/2008 12/22/2008 53490 12.56 4250 2 RH2 28 11/25/2008 12/22/2008 53270 12.56 9240 3 RH2 ❑ Distribute attachments. Average f @ 28 days 9250 Please see reverse side for additional information. Job Number: T0806977. Register Number: 0088504 Date Molded: 11/24 /2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 --IIP < 1 in. [25 mm] X )\\ ;'/Ii\ . • Type I Type 2 Type 3 Reasonable well :formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no • than 1 in. [25 mm] of - through caps, no well - defined well - formed cones • cracking through caps cone on other end \ • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly and of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/29/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CT1's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. , Inc. . onstruction In & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box. 7918 • • Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/24/2008 Job Number: T080697.7. Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETAS Cast By: J. HIETPAS JR. Concrete Supplier: CEMEX Truck #: 7694 Load #: 9 Ticket#: 10193587 Weather: CLEAR Test Time: 9 : 30 AM Air Temp. at Sampling Time: 34 Cylinders were cast for the following locations: MID POINT OF LOAD Total Concrete Placement Location: DRIVEWAY BEHIND BUILDING, LEADING OUT TO WEST ENTRANCE (NO GRID LINES) Strength Requirement: 3000 psi f @ 28 Days Slump: 5.500" % Air: 5.00% Mix Number: 1308248 Conc. Temp: 62 Cement Type: I Max Agg: PEA GRAVEL Admix/Amt: DARA1000 / WRDA64 90/200 +- Cubic Yards: Register Number: 0088505 Lab Location: TIGARD Set Test @ • Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture ' By II 7 11/25/2008 12/01/2008 39208 12.56 3120 2 RH2 28 11/25/2008 12/22/2008 47604 12.56 3790 3 RH2 28 11/25/2008 12/22/2008 49700 12.56 3960 4 RH2 El Distribute attachments. Average f c@ 28 days 3880 Please see reverse side for additional information. Job Number: T0806977. Register Number: 0088505 Date Molded: 11/29 /2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 - < 1 in. [25 mm] • X )\ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly .nd of cylinder is pointed ends: tap with hammer to with unbonded caps) distinguish from Type 1 I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS . TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/29/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. �'onstruction Inspections & Related Tests Carlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard. Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 . Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/26/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: - Cast By: A. NUNLEY Concrete Supplier: CEMEX Truck #: 6071 Load #: 1 Ticket#: 10193606 Weather: OVERCAST Test Time: 7 : 05 AM Air Temp. at Sampling Time: 40 Cylinders were cast for the following locations: Total Concrete Placement Location: SOUTH SIDE DRIVEWAY AND SOUTH END PATIO GRID LINE 3.5 /B —G • . Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 6.00% Mix Number: 130824 8 Conc. Temp: 64 Cement Type: I / I I Max Agg: 3/ 4 Admix/Amt: DARA100 = 31 OZ, WRDA64 = 148 OZ 10 Cubic Yards: Register Number: 0088 62 6 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 12/01/2008 12/03/2008 30527 12.56 2430 2 RH2 14 12/01/2008 12/10/2008 34700 12.49 2780 2 MEM 28 12/01/2008 12/24/2008 45100 12.50 3610 3 MEM 28 12/01/2008 12/24/2008 44500 12.50 3560 4 MEM 0 Distribute attachments. Average fc @ 28 days 3590 Please see reverse side for additional information. Job Number: T0806977 . Register Number: 0088626 Date Molded: 11/26/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < 1 in. [25 mm] • ./).\\ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/29/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. ma. ODe sue.. Bad Oka . Carlson Testing, Inc. X03 Salea OR 97301 : ;u7 O Ma9 /rs Far 15031684-0954 Far 15031589.1309 Fax 0411330.9163 Construction Materials Testing & Inspection Special Inspection FINAL SUMMARY LETTER January 6, 2009 T0806977 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Tualatin Valley Fire & Rescue — Fire Station #50 12617 SW Walnut Street — Tigard, OR Permit# BUP2008-00022 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Adhesive Anchors Structural Masonry Structural Welding- Shop & Field All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's. design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without 'nor authorization from this office. If there a : ny further questions regarding this matter, please do not hesitate to contact this office. Respec r y submitt • CARLS11 . TEST . , INC. m - F. tps P. - Manager J ks Tualatin Valley Fire & Rescue — Gary Wells Lewis & Van Vleet Inc — Lance Cemy Peck Smiley Ettlin Architects — Jeff Bringenberg First Cascade Corporation — Michael Krecklow First Cascade Corporation — Matt Hubei Nah Carlson Testing, Inc. 8430 "° B, St. NE 63025 Rd 911 71grm; OR 07123 Cd OR 97301 Bad OR 97707 Mow (303) 681.3160 Phone (303) 389 -1712 Mow (341) 330.9/55 Construction Materials Testing & Inspection Fm 6031681 OOSI F�6[N /3891300 Fm /51/1 330-9163 Special Inspection FINAL SUMMARY LETTER January 6, 2009 T0508904A City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: CWS Durham Aeration Basin 3 Repair 16060 SW 85 Avenue — Tigard, OR Permit# BUP2008 -00333 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Structural Welding — Field Only All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there ar any further questions regarding this matter, please do not hesitate to contact this office. Respe ly submitted CARLS• TESTING, INC. Jam:- Hietpas Pr. - Manager JF cc. Clean Water Services (Durham) — Joel Borchers Peterson Structural Engineers — Erick Peterson G H McCulloch Inc — Brock Inman Main Office Salem Office Bend Office P.O. Box 23814 j0 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684-3460 FAX (503) 684 -0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 1309 FAX (541) 330 -9163 January 6, 2009 T0806977 Permit No. BUP2008 -00022 FIELD INSPECTION REPORT DATES COVERED: January 6, 2009 PROJECT: Tualatin Valley Fire & Rescue — Fire Station #50 ADDRESS: 12617 SW Walnut Street — Tigard, OR INSPECTOR: Jim Hietpas, Sr. As requested, CTI representative was onsite this date for special inspection to clear outstanding item for finalizing the above - mentioned project. Based on the engineer of record's letter dated August 7, 2008 and drawing, CTI is removing the outstanding note on our report dated August 6, 2008. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectful submitted, CARLS , TESTING, INC. , Ja - : . Hietpas Pr' ect Manager J ' H /ks c: Tualatin Valley Fire & Rescue — Gary Wells City of Tigard Building Division Lewis & Van Vleet Inc — Lance Cerny Peck Smiley Ettlin Architects — Jeff Bringenberg jeff@psearchs.com First Cascade Corporation — Michael Krecklow michaelk @firstcascade.com First Cascade Corporation — Matt Hubei matth @firstcascade.com Template T0806977 vJd . Construction In & Related Tests 'Carlson Testing Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone(503)589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: . ASTM C31 /C172/C192/C617/C1064/C231/C143 Date 'Molded: 12/05/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: . Cast By: J. HAYNES Concrete Supplier: CEMEX Truck #: 6573 Load #: 1 Ticket#: 10193639 Weather: CLEAR Test Time: 10:10 AM Air Temp. at Sampling Time: 42 Cylinders were cast for the following locations: WEST DRIVEWAY APPROACH Total Concrete Placement Location: SAME AS ABOVE Strength Requirement: 3000 psi fc @ 28 Days Slump: 5.000" % Air: 5. 60% Mix Number: 1308248 Conc. Temp: 58 Cement Type: 1 /1 1 Max Agg• 1.0 Admix/Amt: DARA1000 = 31 OZ, WRDA64 = 148 OZ Cubic Yards: 10/30 Register Number: 0088764 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 12/08/2008 12/12/2008 40648 12.56 3240 1 RH2 28 12/08/2008 01/02/2009 55514 12.56 4420 2 RH2 28 12/08/2008 01/02/2009 59111 12.56 4710 3 RH2 28 12/08/2008 01/02/2009 58525 12.56 4660 2 RH2 El Distribute attachments. Average f c@ 28 days 4600 Please see reverse side for additional information. Job Number: T0806977 . Register Number: 0088764 Date Molded: 12/05/2008 Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 —► < 1 in. [25 mm] Type l Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE'& RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 01/06/2009 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. . { :. . . Carlson Testing ,Inc. °11 71gv'{ OR 97727 Salrt Q4 973°! 8nd OR 97701 Roam. (507) 691.3!60 Ma r (303) 3891131 Mom 011)330-913.1 Far 1503) 681 -0951 Far 15 031 589-1309 Fm 15111 33 0 -91 I• Construction Materials Testing &'Inspection • Special Inspection RECEVED FINAL SUMMARY LETTER January 6, 2009 JAN 0 7 2009 T0806977 CITY OF TIGARD PLANNING/ENGINEERIN City of Tigard ' 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Tualatin Valley Fire & Rescue — Fire Station #50 12617 SW Walnut Street - Tigard, OR • . .: Permit# BUP2008 -00022 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following items) per our inspection reports only: Reinforced Concrete Installation of Adhesive Anchors Structural Masonry - Structural Welding- Shop & Field All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders -_ and applicable workmanship provisions of the State Building Code and Standards, as well as the structural.engineer's. design changes, approvals and verbal instructions. . Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced,.except in • full, without • Oar authorization from this office. If there a : ny further questions regarding this matter, please do not hesitate to contact this office. Respec r y submitte• CARLS1i TEST . , INC. m - - F. tps P P. - t Manager J ks Tualatin Valley Fire & Rescue — Gary Wells Lewis & Van Vleet Inc — Lance Cemy Peck Smiley Ettlin Architects — Jeff Bringenberg First Cascade Corporation — Michael Krecklow First Cascade Corporation — Matt Hubei JRN -07 -2009( WED) 09:34 ,- P.001 /001 LEWIS & J S1IO VC • A\\\ 4 17-* io) vria' VAN VLEET �U�`� Inc orpora Letl principals chi-15c. vr,n vlppt. p.e. gag.' J. Icwl5. p.e. FINAL SUMMARY REPORT DATE: January 7, 2009 JOB NO.: 07132 PROJECT: TVF &R Station 50 LOCATION: 12617 SW Walnut Street, Tigard, OR • CONTRACTOR: First Cascade Corp. OWNER: TVF &R PERMIT NO. BUP2008 -00022 • TO: Brian Blalock - City of Tigard Building Division Lewis & Van 'fleet Inc. Consultirw, Engineers prepared structural design docunieuts and monitored the aIn,ve- referenced project throughout its construction. We visited and observed the project throughout the course of construction, and prepared clarification and correction documents as required by the contractor. We also received and reviewed copies of reports from Carlson Testing Inc. regarding required special inspections, including their final summary letter dated January 6, 2009. To the best of our knowledge, the project construction conforms to the calculations, plans and details prepared by this office. Sign ::emY, P Lanc . cc: Jeff Bringenb g — PSE • Michael Kirklow -- First Cascade consulting engineers 18660 s.w. boones ferry road tualatln, oregon 97052 (503] 885.8605 phone • [503] 885.1206 fax • :� • ,r Construction I & Related Tests Carlson Testing, Inc. Geotechnical Consulting • Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS • Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 12/05/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: J. HAYNES Concrete Supplier: CEMEX Truck #: 6573 Load #: 1 Ticket#: 10193639 Weather: CLEAR Test Time: 10:10 AM Air Temp. at Sampling Time: 42 Cylinders were cast for the following locations: WEST DRIVEWAY APPROACH Total Concrete Placement Location: SAME AS ABOVE Strength Requirement: 3000 psi fc @ 28 Days Slump: 5.000" % Air: 5. 60% Mix Number: 1308248 Conc. Temp: 58 Cement Type: I /II Max Agg: 1.0 Admix/Amt: DARA1000 = 31 OZ, WRDA64 = 148 OZ 10/30 Cubic Yards: Register Number: 0088764 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 12/08/2008 12/12/2008 40648 12.56 3240 1 RH2 28 12/08/2008 01/02/2009 28 12/08/2008 01/02/2009 28 12/08/2008 01/02/2009 E l Distribute attachments. Average f @ 28 days Please see reverse side for additional information. 7 Job Number: T0806977. gister Number: 0088764 c ite Molded: 12/05/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 1 in. [25 mm] /)\\ ; Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end f • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly 2nd of cylinder is pointed ends: tap with hammer to with unbonded caps) . distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager:. JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/15/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office :i Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 s� • Tigard, Oregon 97281 Salem, O 97301 Bend, Oregon 97708 Ca 9 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative K. THRALL OBOA 347 was on site this date Dec. 10, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? © Yes No ❑ N/A Name: WATT Company: FIRST CASCADE 2. Monitored loads arriving at job site for correct: Mix #: 1308248 2. Type of work: ® Concrete © Reinforcing 5 .0 % Slump /o Air 5 . 2 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS • 4. Inspection was 'IBC' © Continuous ❑ Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field EI At precast shop 4. Inspected placing and consolidation of approx. 10 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? x 2. Forms clear of debris? SAME AS REINFORCING x 3. Type, grade, size, quantity, spacing and x condition conform? 4. Verified forms will nominally result in hardened concrete of the required x cross- sectional dimensions. • • 5. Verified location of reinforcing steel, pipes, • conduits and sleeves with respect to x minimum concrete cover. 6. Verified type and location of splices, length After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. x 7. Verified support & anchorage of reinforcing REPORT SUMMARY steel in the forms. x 1. Work inspected was: ® Completed El In progress 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications El Shop drawings with regard to weld inspection, quantity, and x E RFI E Design change E Submittal E N/A permits issued. 10. Verified cast in place anchors. Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). D Yes El No ® N/A A REPLACEMENT APPROACH EAST SIDE 4. Noncompliance item(s) were reinspected this date, details on following page(s). © Yes No ❑ N/A ❑ Conform © Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). ❑ Distribute attachments. Page 1 of 2 1 Daily Report of Reinforced Concreted. For: 12/10/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 12/12/2008 KRT /DM TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM �t, Construction Inspections & Related Tests Carlson Testing, Inc; Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF GROUTED BLOCK PRISM TEST SPECIMENS Test Method: ASTM 01314 Date Molded: 10/24/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 ' Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 • Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: KLINGER MASONRY INC • Concrete Supplier: GLACIER NORTHWEST Cast By: D. SUMINSKI Truck #: 400 Ticket #: 194187 Weather: CLEAR Cu Yds: 7 Load #: 1 • Temp High: 65 Temp Low: Location of Placement: CMU WALLS GENERATOR ROOM, TRASH ENCLOSURE, SCREEN WALL AND SIGN Grout Strength Requirement: psi fig @ Test Time: 12:30 PM Grout Temp: 64 Prism Strength Requirement: 1500 psi I'm @ 28 Slump: Grout Type: Grout Mix ID: 885 Type of Mortar: Masonry Unit Type: CMU Register Number: 87676 Lab Location: TIGARD Prism Test @ Date Width Height Length Net Area Max Load Net Compr hp /tp hp /tp Correct. Break No. . in Tested Days Strength Ratio CF Net Str. Type Y ( ) ( in. ) ( in. ) C i ) ( lb. ) (Psi) (Psi) YP IA 28 11/21/2008 7.66 16.09 8.57 65.64 182800 2780 2.10 1.008 2800 3A IB 28 11/21/2008 7.65 16.22 8.54 65.33 198500 3040 2.12 1.016 3090 4B Compressive Strength of Masonry: fm psi (average or 1.25 x least individual value, whichever is less) • Distribute attachments. Please see reverse side for additional information. Job Number: T0806977. M Register Number: 87676 NDate Molded: 10/24/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 1) Conical Break 2) Cone & Shear 3) Cone & Split rill FM rfi A 11 11 IA ) IN Side B i \ FM Side A (End) A B A B A B (Front) 5) Semi- Conical 7) Face Shell 4) Tension Break Break 6) Shear Break Separation R 11 w LEI a / - _ A B A B A B A B The net area of concrete masonry units other than 100% solid units is determined by test method C140. The compression machine upper bearing plate dimensions are 20 "L x 14 "W x 4 "T and the lower plate dimensions are 20 "L x 14 "W x 4 "T. Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/24/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms am conditions of CTI's General Conditions in effect at the time of this report is prepared. No party other than those to whom P P P rtY m o CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. * � Inc. Construction Inspections & Related Tests 'Carlson Testing I Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/27/2008 Job Number: T0806977 . Permit #:. BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast By: A. LEWIS Concrete Supplier: CEMEX Truck #: 6071 Load #: 2 Ticket#: 126153 Weather: CLEAR Test Time: • 1:30 PM Air Temp. at Sampling Time: 71 • Cylinders were cast for the following locations: PARKING AREA ON EAST SIDE OF STRUCTURE. Total Concrete Placement Location: SAME AS ABOVE NOTE: SET ONE WAS 6X12'S FABRICATED THIS MORNING. THIS IS SET 2 AND THEY ARE ' 4X8'S! Strength Requirement: 3000 psi f c @ 28 Days Slump: 5.000" % Ai 1 . 90% Mix Number: 1308248 Conc. Temp: 65 Cement Type: i /II Max Agg: 1. Admix/Amt: Cubic Yards: 21 Register Number: 0087748 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI F racture By II 7 10/28/2008 11/03/2008 34983 12.56 2790 3 AF 28 10/28/2008 11/24/2008 59000 12.56 4700 4 MEM 28 10/28/2008 11/24/2008 56700 12.56 4510 3 MEM 28 10/28/2008 11/24/2008 61700 12.56 4910 4 MEM ❑ Distribute attachments. Average fc @ 28 days 4 710 Please see reverse side for additional information. .Job Number: T0806977. IIIIIkister Number: 0087748 fate Molded: 10/27/2008 Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 — 1 < 1 in. [25 mm] )\\ ij\■ ` Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly znd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/25/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. , r • �l 'T .• Inc. onstruction Inspections & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 • • Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 - 1252 Phone (541) 330 -9155 • Fax (503) 684 -0954 Fax (503) 589 - 1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/06/2008 Job Number: T0806977 . Permit #:. BUP2008 - 00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETA CONCRETE Cast By: K. THRALL - Concrete Supplier: CEMEX Truck #: 1 Load #: 1 Ticket#: 22927906 Weather: OVERCAST Test Time: 1: 15 PM Air Temp. at Sampling Time: 61 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST APPROACH . Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 15.00% Mix Number: 13 0 Conc. Temp: 7 2 Cement Type: I / I I Max Agg: 3 /4 Admix/Amt: AEA = 3 OZ, POZZ = 20 OZ, NC534 = 1% Cubic Yards: 10 Register Number: 0088015 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 11/07/2008 11/13/2008 28699 12.56 2280 3 RH2 28 11/07/2008 12/04/2008 19274 12.56 1530 4 • RH2 28 11/07/2008 12/04/2008 18072 12.56 1440 3 RH2 28 11/07/2008 12/04/2008 21326 12.56 1700 3 RH2 ❑ Distribute attachments. Average re @ 28 days 1560* Please see reverse side for additional information. r ;14. Job Number: T0806977 . ister Number: 0088015 te Molded: 11/06/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 - < 1 in. [25 mm] i Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly mnd of cylinder is pointed • ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. • Remarks: TALK TO GARY WELLS AND SLAB ON GRADE WILL BE REMOVED ASAP 12/09/2008 PER J. HIETPAS TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/05/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • `fi Carlson Testing, Inc. k- NCL of Low Compressive Strength Tests & Compaction Tests Dec 08, 2008 T0806977. • Project Name: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Project Address: 12617 SW WALNUT STREET TIGARD OR Permit No: BUP2008 -00022 P.O. No: Project Manager: JAMES F. HIETPAS • Compliance CTl Sign -Off Date Correcte Sample Type Register # Date Molded Date Tested Set # Days PSI Strength Reg Concrete 88015 11/06/2008 12/04/2008 28 1530 3000 Concrete 88015 11/06/2008 12/04/2008 28 1440 3000 Concrete 88015 11/06/2008 12/04/2008 28 1700 3000 Average f'c @ 28 days 1556 Location: EAST APPROACH • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO :CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY CARLSON GEOTECHNICAL - RYAN HOUSER PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG FIRST CASCADE CORPORATION - MICHAEL KRECKLOW FIRST CASCADE CORPORATION - MATT HUBEL Page: 1 SO Inc. onstruction In & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard. Oregon 97281 Salem, Oregon 97301 Bend. Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone(541)330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 6 X 12 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/27/2008 Job Number: T0806977. Permit #: BUP2008 -00022 . Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project : TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast By: A. LEWIS Concrete Supplier: CEMEX Truck #: 2462 Load #: 1 Ticket#: Weather: CLEAR Test Time: 8 : 05 AM Air Temp. at Sampling Time: 59 Cylinders were cast for the following locations: UNREINFORCED SIDEWALK ON EAST SIDE OF BUILDING. CYLINDERS CAST EAST AT CONTRACTOR'S REQUEST. Total Concrete Placement Location: SAME AS ABOVE Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" %fi 1 . 90% Mix Number: 1308248 Conc. Temp: 62 Cement Type: I /1 I Max Agg: . 1 . 0 Admix/Amt: Cubic Yards: 12 Register Number: 0087751 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/28/2008 11/03/2008 73900 28.18 2620 2 BR 28 10/28/2008 11/24/2008 117556 28.26 4160 3 RH2 28 10/28/2008 11/24/2008 111056 28.26 3930 2 RH2 28 10/28/2008 11/24/2008 117325 28.26 4150 3 RH2 • ❑ Distribute attachments. Average Cc @ 2 8 days 4080 Please see reverse side for additional information. Job Number: T0806977. isterNumber: 0087751 OIL Molded: 10/ 27/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < l in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end • • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/25/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. , e Construction Inspections & Related Tests 'Cartson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/28/2008 Job Number: T0806977 . Permit #: BUP2008- 00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW - . Subcontractor: Cast By: K. THRALL Concrete Supplier: CEMEX • Truck #: 7667 Load #: 3 Ticket#: 22922347 Weather: SUNNY Test Time: 8: 30 AM Air Temp. at Sampling Time: 4 4 Cylinders were cast for the following locations: . Total Concrete Placement Location: EAST CURB LINE DRIVE FROM CATCH BASIN TO LIGHT POLE Strength Requirement: 3000 psi f c @ 28 Days Slump: 5.500" % Air: 4.80% Mix Number: 1308248 Conc. Temp: 7 1 Cement Type: i / I I Max Agg• 3 / 4 Admix/Amt: Cubic Yards: 30 Register Number: 0087778 Lab Location: TIGARD • Set Test @ Date Test Total Unit Type Of Tested No. Days Rec'd Date Load Area. PSI Fracture By I 7 10/29/2008 11/04/2008 44700 12.56 3560 2 RH2 28 10/29/2008 11/25/2008 61567 12.56 4900 2 WR 28 10/29/2008 11/25/2008 65653 12.56 5230 2 WR 28 10/29/2008 11/25/2008 62067 12.56 4940 3 WR E Distribute attachments. Average fc @ 28 days - 5020 Please see reverse side for additional information. Job Number: T080 6977. Illitister 0087778 ite Molded: 10/28 /2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < 1 in. [25 mm] • ■ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends: tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Inc. onstruction In & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/28/2008 Job Number: T0806977. Permit #:... BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL .KRECKLOW Subcontractor: Cast By: K. THRALL Concrete Supplier: CEMEX . Truck #: 6573 Load #: 1 Ticket#: 22922652 Weather: SUNNY Test Time: 1:30 PM Air Temp. at Sampling Time: 61 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST PARKING SOUTH END Strength Requirement: 3000 psi f c@ 28 Days Slump: 6.000" % Air: 4.80% Mix Number: 1308248 Conc. Temp: 7 1 Cement Type: i / I i Max Agg: 3 / 4 • Admix/Amt: Cubic Yards: 10/20 + Register Number: 0087779 Lab Location: TIGARD Set Test @ . Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By II 7 10/29/2008 11/04/2008 42800 12.56 3410 3 RH2 28 10/29/2008 11/25/2008 58054 12.56 4620 2 WR 28 10/29/2008 11/25/2008 52429 12.56 4170 2 WR 28 10/29/2008 11/25/2008 55725 12.56 4440 1 WR ❑ Distribute attachments. Average f c @ 28 days 4 410 Please see reverse side for additional information. Job Number: T0806977. leister 0087779 OIL Molded: 10/28/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < 1 in. [25 mm] )\\ . Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly .tnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • 11 1. 0 Construction Inspections & Related Tests Carlson Testing, Inc. Geotechnical Consulting • Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 . Fax(503)684 -0954 Fax(503)589 -1309 Fax(541)330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/26/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 • Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast -By: A. NUNLEY Concrete Supplier: CEMEX Truck #: 6071 Load #: 1 Ticket#: 10193606 Weather: OVERCAST Test Time: 7 : 05 AM Air Temp. at Sampling Time: 40 Cylinders were cast for the following locations: Total Concrete Placement Location: SOUTH SIDE DRIVEWAY AND SOUTH END PATIO GRID LINE 3.5 /B —G Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 6.00% Mix Number: 130824 8 Conc. Temp: 64 Cement Type: 1 /1 I Max Agg: 3/ 4 Admix/Amt: DARA100 = 31 OZ, WRDA64 = 148 OZ 10 Cubic Yards: Register Number: 0088626 Lab Location: TIGARD Set • Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 12/01/2008 12/03/2008 30527 12.56 2430 2 RH2 28 12/01/2008 12/24/2008 28 12/01/2008 12/24/2008 • 28 12/01/2008 12/24/2008 0 Distribute attachments. Average f @ 28 days Please see reverse side for additional information. Job Number: T0806977 . Glister Number: 0088626 Otte Molded: 11/26/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 --� < 1 in. [25 mm] • X Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 --- Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly 2nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/04/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • Construction Inspections & Related Tests 'Carlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/24/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 .. .Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor:. FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETAS Cast By: J. HIETPAS JR. Concrete'Supplier: CEMEX Truck #: 6070 Load #: 1 Ticket#: 1019357 9 Weather: CLEAR Test Time: 7 : 10 AM Air Temp. at Sampling Time: 30 Cylinders were cast for the following locations: MID POINT OF LOAD Total Concrete Placement Location: DRIVEWAY BEHIND BUILDING LEADING OUT TO WEST ENTRANCE (NO GRID LINES) Strength Requirement: 3000 psi fc @ 28 Days Slump: 5.500" % Air: 4 . 80% Mix Number: 1308248 Conc. Temp: 60 Cement Type: I Max Agg: PER GRAVEL Admix/Amt: DARA1000 = 30 OZ, WRDA64 = 148 OZ 10/200 +- Cubic Yards: Register Number: 0088504 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 11/25/2008 12/01/2008 33370 12.56 2660 2 RH2 28 11/25/2008 12/22/2008. 28 11/25/2008 12/22/2008 0 Distribute attachments. Average fc @ 28 days Please see reverse side for additional information. • Job Number: T0806977. •gisterNumber: 0088504 ate Molded: 11/24/2008 Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 — . 11 ‘ , .< 1 in. [25 mm] Type 1 Type 2 Type 3 Reasonable well- formed Well - Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well- formed cones cracking through caps cone on other end • • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly z.nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/02/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • 0 SConstruction Inspections & Related Tests Inc. .Carlson Testing, Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 ' Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/24/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 • Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS • Project•'TUALAT VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: ARRIETAS Cast By: J. HIETPAS JR. Concrete Supplier: CEMEX Truck #: 7694 Load #: 9 Ticket#: 10193587 Weather: CLEAR Test Time: 9: 30 AM Air Temp. at Sampling Time: 34 Cylinders were cast for the following locations: MID POINT OF LOAD Total Concrete Placement Location: DRIVEWAY BEHIND BUILDING, LEADING OUT TO WEST ENTRANCE (NO GRID LINES) Strength Requirement: 3000 psi f c @ 28 Days Slump: 5.500" % Air: 5.00% . Mix Number: 1308248 Conc. Temp: 62 Cement Type: I Max Agg: PEA GRAVEL Admix/Amt: DARA1000 / WRDA64 90/200 +- Cubic Yards: Register Number: 0088505 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By II 7 11/25/2008 12/01/2008 39208 12.56 3120 2 RH2 28 11/25/2008 12/22/2008 28 11/25/2008 12/22/2008 El Distribute attachments. Average rc @ 28 days Please see reverse side for additional information. Job Number: T0806977 . (Mister Number: 0088505 Sate Molded: 11/24/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < 1 in. [25 mm] )\\\ Type 1 Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end f Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly ..nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/02/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. e Construction Inspections & Related Tests C arlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/21/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 j Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION – MICHAEL KRECKLOW Subcontractor: Cast By: J. HIETPAS JR. Concrete Supplier: CEMEX Truck #: 6071 • Load #: 1 Ticket#: 10193564 Weather: PARTLY CLOUDY Test Time: 8: AM Air Temp. at Sampling Time: 50 Cylinders were cast for the following locations: MID POINT Total Concrete Placement Location: SLAB ON GRADE BEHIND FIRE HOUSE Strength Requirement: 3000 psi f'c @ 28 Days Slump: 5.000" % Air: 5.40% Mix Number: 1308248 Conc. Temp: 63 Cement Type: I Max Agg: PER GRAVEL Admix/Amt: DARASET = 29 OZ, WRDA64 = 122 OZ 10/40 +– Cubic Yards: Register Number: 0088421 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 11/24/2008 11/28/2008 39612 12.49 3170 3 RH2 28 11/24/2008 12/19/2008 • 28 . 11/24/2008 12/19/2008 28 11/24/2008 12/19/2008 ri Distribute attachments. Average f c @ 28 days Please see reverse side for additional information. Job Number: T0806977. glister Number: 0088421 •ate Molded: 11/21/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 --► < 1 in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly .tnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • j Inc. Construction In & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard. Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503)684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/31/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 . Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETA' S CONCRETE Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 6070 Load #: 1 Ticket#: 22924 7 8 0 Weather: RAIN Test Time: 10 : 15 AM Air Temp. at Sampling Time: 52 Cylinders were cast for the following locations: TRASH AND FUEL PUMP ENCLOSURE SLAB Total Concrete Placement Location: ABOVE, PLUS EAST DRIVE CENTER AND SECTION J SOUTH END, 60' SOUTH TO NORTH (LIGHT POLE TO LIGHT POLE) Strength Requirement: 3000 psi fc @ 28 Days Slump: 4.500" % Air: 4 . 90% Mix Number: 130824 8 Conc. Temp: 62 Cement Type: I/ I I Max Agg• 3/ 4 Admix/Amt: Cubic Yards: 10/20 Register Number: 0087927 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 11/03/2008 11/07/2008 47380 12.56 3770 2 RH2 28 11/03/2008 11/28/2008 65667 12.49 5260 3 RH2 28 11/03/2008 11/28/2008 61639 12.49 4940 2 RH2 28 11/03/2008 11/28/2008 65163 12.49 5220 3 RH2 Distribute attachments. Average f c@ 28 days 514 0 Please see reverse side for additional information. Job Number: T0806977. Illtster 0087927 MIL Molded: 10/31 /2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 —♦ < 1 in. [25 mm] • j ' i\ x Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. * .• ID 0 Construction Inspections & Related Tests .Carlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/30/2008 Job Number: T0806977 . Permit #:', BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: FIRST CASCADE Cast By: A. LEWIS Concrete Supplier: CEMEX Truck #: 6071 Load #: 1 Ticket#: 2293710 Weather: OVERCAST Test Time: 8 : 15 AM Air Temp. at Sampling Time: 52 Cylinders were cast for the following locations: SE QUADRANT OF PARKING LOT SLAB ON GROUND Total Concrete Placement Location: SAME AS ABOVE Strength Requirement: 3000 psi t'c @ 28 Days Slump: 5.000" % Air: 4 .50% Mix Number: 13082 4 8 Conc. Temp: 64 Cement Type: I/ 1 I Max Agg: 3/ 4 Admix/Amt: Cubic Yards: 20 Register Number: 0087837 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/31/2008 11/06/2008 41381 12.62 3280 4 RH2 28 10/31/2008 11/27/2008 60700 12.49 4860 3 MEM 28 10/31/2008 11/27/2008 61000 12.49 4880 3 MEM 28 10/31/2008 11/27/2008 60900 12.49 4880 4 MEM 0 Distribute attachments. Average f c @ 28 days 4870 Please see reverse side for additional information. Job Number: T0806977. •gisterNumber: 0087837 /bate Molded: 10/30/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 -- 11 0. < 1 in. [25 mm] Type l Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end f Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. • Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Inc. all Constructio In & Related Tests 'Carlson Testing, I Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 • REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/29/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETAS CONCRETE Cast By: K. THRALL • Concrete Supplier: CEMEX Truck #: 6071 Load #: 2 Ticket#: 22922958 Weather: FOGGY Test Time: 8 : 30 AM Air Temp. at Sampling Time: 45 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST DRIVE CENTER AND SECTION CATCH BASIN TO LIGHT POLE Strength Requirement: 3000 psi t'c @ 28 Days Slump: 6. 000" % Air: 5.20% Mix Number: 130824 8 Conc. Temp: 72 Cement Type: I / I I Max Agg: 3/ 4 Admix/Amt: • Cubic Yards: 20/40 Register Number: 0087803 Lab Location: TIGARD . Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/30/2008 11/05/2008 44479 12.56 3540 2 RH2 28 10/30/2008 11/26/2008 61200 12.50 4900 3 MEM 28 10/30/2008 11/26/2008 66800 12.50 5340 4 MEM 28 10/30/2008 11/26/2008 59600 12.50 4770 3 MEM ❑ Distribute attachments. Average f c @ 28 days 5000 Please see reverse side for additional information. • .Job Number: T0806977. Illikister Number: 0087803 •ate Molded: 10/29/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 . < 1 in. [25 mm] i t s /)\\ . I l Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly 2nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance. criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/01/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Inc. Construction Inspections & Related Tests Carlson Testing d Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503)684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRET TEST SPECIMENS • Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 11/26/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: A. NUNLEY Concrete Supplier: CEMEX Truck #: 6071 Load #: 1 Ticket#: 10193606 Weather: OVERCAST Test Time: 7 : 05 AM Air Temp. at Sampling Time: 4 0 Cylinders were cast for the following locations: Total Concrete Placement Location: SOUTH SIDE DRIVEWAY AND SOUTH END PATIO GRID LINE 3.5 /B -G J Strength Requirement: 3000 psi t'c @ 28 Days Slump: 6. 000" % Air: 6. 00% Mix Number: 1308248 Conc. Temp: 64 Cement Type: I /II Max Agg• 3/ Admix/Amt: DARA100 = 31 OZ, WRDA64 = 148 OZ Cubic Yards: 10 ' Register Number: 0088626 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 12/01/2008 12/03/2008 30527 12.56 2430 2 RH2 14 12/01/2008 12/10/2008 34700 12.49 2780 2 MEM 28 12/01/2008 12/24/2008 28 12/01/2008 12/24/2008 ❑ Distribute attachments. Average fc @ 28 days Please see reverse side for additional information. Job Number: T0806977. Register Number: 0088626 Date Molded: 11/26/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 -- 1 < 1 in. [25 mm] )\\ . ' 1 Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running , through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly .tnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. • Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM • Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 12/10/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CT1's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. 11/18/08 TUE 10:21 FAX 503 601 8254 Carlson Geotechnical 2]001 Car sail Geotechnical Main x2381 Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 9T 08 Geotechnical Consulting Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Construction Inspection and Related Tests FAX (503) 670.9147 FAX (503) 589.1309 FAX (541) 3309163 Final Summary Letter (1,6 ,2c S' - ao 2 Z November 17, 2008 Mr. Gary Wells Tualatin Valley Fire & Rescue 20665 SW Blanton Street Aloha, Oregon 97007 Final Summary Letter of Geotechnical Construction Observation Services Walnut Street Fire Station 12585 SW Walnut Street Tigard, Oregon CGT Project Number G0602953A Carlson Geotechnical (CGT) served as Geotechnical Engineer of Record (EoR) for the Walnut Street Fire Station located at 12585 SW Walnut Street in Tigard, Oregon. As geotechnical engineer, we performed a geotechnical investigation of the site, the results of which were presented in our Report of Geotechnical Investigation and Site - Specific Seismic Hazards Study dated January 9, 2007. CGT performed geotechnical construction observation services during site grading on an on -call, part -time basis between April 18, 2008, and October 28, 2008. Our site visits were scheduled by your contractor, First Cascade Corporation. Copies of our field reports were forwarded to you as the work progressed, and are available in our office for your review. The following is a summary of our observations: • Site Stripping: Based on our field observations, the site was stripped of surface vegetation, undocumented fill, and organic topsoil in building and pavement areas in general accordance with our recommendations. In addition, concrete footings and pavements associated with previous structures were removed from the site. • Subgrade Soils: Based on the results of our proofrolling and probing, the subgrade soils within parking lot and building locations were prepared in general accordance with our recommendations. • Site Grading: Site grading consisted of the placement and compaction of 1 crushed rock imported from Cobb Rock. Based on laboratory testing, the material contained over 30 percent in excess of 1' /cinches, making testing with nuclear density gauge unreliable. Up to approximately 8 feet of structural fill was placed under the northern portion of the site. CGT observed proof -rolls of the structural fill in parking and building 11/18/08 TUE 10:21 FAX 503 ' ' 8254 Carlson Geotechnical (]002 Walnut Street Fire Station Tigard, Oregon CGT Project Number G0602953A November 17, 2008 areas, which indicated that they were placed in general accordance with our recommendations. • Building Subgrade: Based on our field observations, the native subgrade for the fire station was prepared in general accordance with our recommendations. Preparation activities included overexcavation of soft sandy silt soils present across the site to provide a minimum of 16 inches of imported granular fill under all footing and slab elements. Compaction of the granular fill was confirmed by proof -roll observation and observation of additional compactive effort. Based on our observations, the granular fills placed within the overexcavation areas were compacted in general accordance with our recommendations. • Footing Subgrades: Based on our observations, the footing subgrades located within the footprint of the fire station and trash enclosure were prepared in general accordance with our recommendations. • Floor Slab Subgrade and Base Rock: Based on our proof -roll observations, the subgrade and base rock for the floor slab areas located within the footprint of the fire station were prepared in general accordance with our recommendations. • Pavement Subgrade and Base Rock: Parking lot areas were overexcavated to provide a minimum of 12 inches of imported granular structural fill under concrete pavement subgrade elevation in order to limit settlement. The southern portion of the west parking area overlapped the footprint of the former residence location, which had been previously backfilled with fill. The fill was overexcavated to firm native subgrade and replaced with documented structural fill. Based on the results of our probing and proof -roll observations, the pavement subgrade soils and base rock we observed, which typically consisted of granular structural fill or native sandy silt soils, were prepared in general accordance with our recommendations. Based on our observations, as documented in our field reports, and to the best of our knowledge, within our scope of work, the above geotechnical summaries accurately reflect our observations. Our services were provided on an on -call, part-time basis, in which we relied on the contractor to contact our office for the scheduling of our services. We cannot be held contractually responsible for those items, if any, that we did not observe or test. Carlson Geotechnical Page 2 of 3 11/18/08 TUE 10:21 FAX 503 "1. 8254 Carlson Geotechnical ll003 Walnut Street Fire Station Tigard, Oregon CGT Project Number G0602953A November 17, 2008 Should you have any questions regarding the recommendations or opinions presented in this report, please contact us at (503) 601 -8250. Sincerely, CARLSON GEOTECHNICAL h f OREGON , C ' , RYAN T. MOUSER / Il / ..4� y � i f.. ,30.0 Ryan T. Houser, CEG William M. Weyrauch, P.E. Senior Engineering Geologist Principal Geotechnical Engineer rhouser aPcarlsontestino.com bwevrauchncarlsontesting.com Distribution: Mr. Gary Wells, TVFR, Mail Daniel Watkins, City of Tigard Building Department, FAX: 503.624.3681 Lance Cerny, Lewis & Van Vleet, FAX: 503.885.1206 Jeff Bringenberg, Peck Smiley Ettlin Architects, FAX: 503.248.0223 Michael Krecklow, First Cascade Corporation, FAX: 503.699.8985 Kendra Laminack, PBS Environmental, FAX: 360.696.9064 • Doc ID: G:IGEOTECIi1PROJECTS12006 ProjectsVrtgard Fire Station COSIFInaI Summary Letter.doc Carlson Geotechnical Page 3 of 3 • •\ • - Main Office .item Office Bend Office • P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS • Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977 . Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD ' CTI representative K. THRALL OBOA 347 was on site this date Nov. 06, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? ® Yes ❑ No ❑ N/A Name: MATT Company: FIRST CASCADE 2. Monitored loads arriving at job site for correct: • Mix #: 130 2. Type of work: © Concrete fl Reinforcing Slump 6 % Air 15.0* 3. Work included: © Sampling 0 Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous 1=1 Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field El At precast shop 4. Inspected placing and consolidation of approx. 10 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? X 2. Forms clear of debris? X EAST APPROACH 3. Type, grade, size, quantity, spacing and X condition conform? *TWO TESTS TAKEN - APPROX. 6 CY APART 4. Verified forms will nominally result in hardened concrete of the required X THE FOLLOWING NON - COMPLIANCE ITEM WAS ADDED: cross - sectional dimensions. * NCL #1: AIR CONTENT 16 %, MAX ALLOWED 6 1/2" AS • 5. Verified location of reinforcing steel, pipes, X PER APPROVED MIX DESIGN. •conduits and sleeves with respect to minimum concrete cover. 6. Verified type and location of splices, length X After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. 7. Verified support & anchorage of reinforcing REPORT SUMMARY steel in the forms. X 1. Work inspected was: ® Completed In progress 8. Verified structural embedments in the forms 2. Completed work inspected was not in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications Shop drawings with regard to weld inspection, quantity, and X ❑ RFI ❑ Design change 0 Submittal ❑ N/A permits issued. • 10. Verified cast in place anchors. X Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). ® Yes El No N/A 4. Noncompliance item(s) were reinspected this date, details • on following page(s). 0 Yes ❑ No © N/A E Conform ❑ Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. ® See additional report page(s). ❑ Distribute attachments. Page 1 of 2 .J Daily Report of Reinforced Conci For: 11/06/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/13/2008 KRT /CK TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM • Carlson Testing, Inc. Incompleted Items List (NCL) Nov 14, 2008 • T0806977. Project Name: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Project Address: 12617 SW WALNUT STREET TIGARD OR Permit No: BUP2008 -00022 P.O. No: Project Manager: JAMES F. HIETPAS Item # Insp. Date Item Description • Compliance CTI Sign -Off Date Corrected 1 KRT 11/06/2008 AIR CONTENT 15% - MAX ALLOWED IS 6 1/2" AS PER APPROVED MIX DESIGN. • •A TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO:CITY'OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY CARLSON GEOTECHNICAL - RYAN HOUSER • )- PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG FIRST CASCADE CORPORATION - MICHAEL KRECKLOW . FIRST CASCADE CORPORATION - MATT HUBEL Page: 1 • • • • V' 1 ,onstruction Inspections & Related Tests 'Carlson Testing, Inc. Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS 'Test'Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/15/2008 Job Number: T0806977 . • Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: M. LARSON Concrete Supplier: X Truck #: 6071 Load #: 1 Ticket#: 22915508 Weather: CLOUDY /COOL Test Time: 2:00 PM Air Temp. at Sampling Time: 62 Cylinders were cast for the following locations: Total Concrete Placement Location: 3 LIGHT POLE BASES; 1 EAST, 1 WEST, AND 1 SOUTH OF BUILDING • Strength Requirement: 3000 psi f @ 28 Days Slump: 4.250" % Air: 5.00 0 Mix Number: 1308248 Conc. Temp: 66 Cement Type: Max Agg: 3/4 ' Admix/Amt: AEA Cubic Yards: 5 Register Number: 0087443 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/16/2008 10/22/2008 40955 12.49 3280 2 RH2 28 10/16/2008 11/12/2008 58681 12.56 4670 3 RH2 28 10/16/2008 11/12/2008 61179 12.56 4870 2 RH2 . 28 10/16/2008 11/12/2008 61821 12.56 4920 2 RH2 • • .0 Distribute attachments. Average fc @ 28 days 4820 Please see reverse side for additional information. Job Number: T0806977. Register Number: 0087943 Date Molded: 10/15/200 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 - ► < 1 in. [25 mm] Type 1 Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well- formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/14/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Inc. Construction In & Related Tests Testing, es ing, I Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503)684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS • Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 ,Date Molded: 11/06/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: ARRIETA CONCRETE Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 1 Load #: 1 Ticket#: 22927406 Weather: OVERCAST Test Time: 1: 15 PM Air Temp. at Sampling Time: 61 Cylinders were cast for the following locations: • Total Concrete Placement Location: EAST APPROACH Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 15.00% Mix Number: 130 Conc. Temp: 72 Cement Type: I / I i Max Agg: 3/ 4 Admix/Amt: AEA = 3 OZ, POZZ = 20 OZ, NC534 = 1% 10 Cubic Yards: Register Number: 0088015 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSl Fracture By I 7 11/07/2008 11/13/2008 28699 12.56 2280 3 RH2 28 11/07/2008 12/04/2008 28 11/07/2008 12/04/2008 28 11/07/2008 12/04/2008 a Distribute attachments. Average f c@ 28 days Please see reverse side for additional information. Job Number: T0806977 . . Register Number: 0088015 Date Molded: 11/06/208 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 < 1 in. [25 mm] )\\\ Type 1 Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well- defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly ..nd of cylinder is pointed ends: tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. • Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/14/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. *• .:onstruction Inspections & Related Tests Carlson Testing, Inc. Geotechnical Consulting • Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 • REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/31/2008 Job Number: T0806977. Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: ARRIETA' S CONCRETE Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 6070 Load #: 1 Ticket#: 22924780 Weather: RAIN Test Time: 10:15 AM Air Temp. at Sampling Time: 52 Cylinders were cast for the following locations: TRASH AND FUEL PUMP ENCLOSURE SLAB Total Concrete Placement Location: ABOVE, PLUS EAST DRIVE CENTER AND SECTTION J SOUTH END, 60' SOUTH TO NORTH (LIGHT POLE TO LIGHT POLE) Strength Requirement: 3000 psi f c @ 28 Days Slump: 4.500" % Air: 4 . 90% Mix Number: 1308248 Conc. Temp: 62 Cement Type: I/ I I Max Agg: 3/4 . Admix/Amt: Cubic Yards: 10/20 Register Number: 0087927 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. , Days Rec'd Date Load PSI Fracture By I 7 11/03/2008 11/07/2008 47380 12.56 3770 2 RH2 28 11/03/2008 11/28/2008 28 11/03/2008 11/28/2008 28 11/03/2008 11/28/2008 . 0 Distribute attachments. Average fc @ 28 days Please see reverse side for additional information. Job Number: T0806977. Register Number: 0087927 Date Molded: 10/31/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 --� < 1 in. [25 mm] d Type l Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/10/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office .,alem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 -Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative K. THRALL OBOA 397 was on site this date Oct. 31, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE _1. Checked in with superintendent or client representative. 1. Mix Design approved? ® Yes ❑ No ❑ N/A Name: MATT Com an FIRST CASCADE 2. Monitored loads arriving at job site for correct: P y Mix #: 1308298 2. Type of work: © Concrete © Reinforcing Slump 4 . 5 % Air 4 . 9 3. Work included: IN Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous ❑ Periodic Number of sets 1 Samples per set 1 5. Work performed: ® In the field ❑ At precast shop 4. Inspected placing and consolidation of approx. 20 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? x 2. Forms clear of debris? SAME AS REINFORCING - x 3. Type, grade, size, quantity, spacing and x condition conform? 4. Verified forms will nominally result in hardened concrete of the required x cross - sectional dimensions. 5. Verified location of reinforcing steel, pipes, conduits and sleeves with respect to X minimum concrete cover. 6. Verified type and location of splices, length After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. X REPORT SUMMARY 7. Verified support & anchorage of reinforcing x I. Work inspected was: Completed In progress steel in the forms. P ® P ❑ P g 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. © Approved plans and specifications ❑ Shop drawings 9. Verified structrual embedments in the forms with regard to weld inspection, quantity, and x ❑ RFI ❑ Design change ❑ Submittal ❑ N/A • permits issued. • 10. Verified cast in place anchors. x Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). ❑ Yes ❑ No ® N/A • EAST DRIVE CENTER SECTION APPDX. 60' FROM SOUTH 4. Noncompliance item(s) were reinspected this date, details TO NORTH; FROM SOUTH END (LIGHT POLE TO LIGHT on following page(s). ❑ Yes ❑ No © N/A POLE) TRASH AND FUEL PUMP ENCLOSURE SLAB 1=1 Conform 1=1 Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE . Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. ❑ See additional report page(s). ❑ Distribute attachments. Page 1 of 1 Daily Report of Reinforced Concrt._ For: 10/31/2008 CTI Job #: T0806977 . Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/11/2008 KRT /ARR TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM • .:onstruction Inspections & Related Tests 'Carlson Testing, Inc. Geotechnical Consulting • Main Office Salem Office Bend Office . P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/08/2008 Job Number: T0806977 . - Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS . Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD 'Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: Y. VITRUK Concrete Supplier: CEMEX Truck #: 2459 Load #: 1 Ticket#: 10196726 Weather: CLEAR Test Time: 12 : 25 Air Temp. at Sampling Time: 53 Cylinders were cast for the following locations: SAME AS BELOW Total Concrete Placement Location: FOOTINGS FOR: PYLON SIGN TRASH ENCLOSURE AND TWO GENERATOR ENCLOSURES. Strength Requirement: 3000 psi Pc @ 28 Days Slump: 3.500" % Air: 1.40% Mix Number: 1308161 Conc. Temp: 62 Cement Type: I /1 I Max Agg: 3/ 4 Admix/Amt: Cubic Yards: 6 . Register Number: 0087281 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/09/2008 10/15/2008 42140 12.56 3360 3 RH2 28 10/09/2008 11/05/2008 64282 12.56 5120 4 RH2 28 10/09/2008 11/05/2008 66418 12.56 5290 3 RH2 . 28 10/09/2008 11/05/2008 64439 12.56 5130 2 RH2 El Distribute attachments. Average Pc @ 28 days 5180 Please see reverse side for additional information. Job Number: T0806977. - Register Number: 0087281 Date Molded: 10/08/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 -- a' <1 in. [25mm] )\\ 7 / g1 \ Type l Type 2 Type 3 Reasonable well - formed Well - Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end J \ Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly tnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/06/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. T Inc. .2onstruction In & Related Tests ,Carison 1 esting, I Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Te Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date.Molded: 10/29/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE — GARY WELLS 1 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: ARRIETAS CONCRETE Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 6071 Load #: 2 Ticket#: 22922958 Weather: FOGGY Test Time: 8:30 AM Air Temp. at Sampling Time: 4 5 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST DRIVE CENTER AND SECTION CATCH BASIN TO LIGHT POLE Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 5.20% Mix Number: 13082 4 8 Conc. Temp: 7 2 Cement Type: I/ I I Max Agg• 3/ 4 Admix/Amt: Cubic Yards: 20 / 4 0 Register Number: 0087803 Lab Location: TIGARD Set Test @ Date Test Total Unit Type Of Tested No. Days Rec'd Date Load Area PSI Fracture By I 7 10/30/2008 11/05/2008 44479 12.56 3540 2 RH2 28 10/30/2008 11/26/2008 28 10/30/2008 11/26/2008 28 10/30/2008 11/26/2008 El Distribute attachments. Average f c@ 28 days Please see reverse side for additional information. Job Number: T 0806977 - Register Number: 0087803 Date Molded: 10/29/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 — < 1 in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than I in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/06/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. - onstruction Inspections & Related Tests _ - Carlson Testing, Inc. nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard. Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone(503)589 -1252 Phone (541) 330 -9155 • Fax (503) 684 -0954 . Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31/ C172/C192/C61 7/C1064/C231/C143 • Date Molded: 10/28/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Cli TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD • Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 7 667 Load #: 3 Ticket#: 22 92234 7 Weather: SUNNY Test Time: . 8 : 30 AM Air Temp. at Sampling Time: 4 4 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST CURB LINE DRIVE FROM CATCH BASIN TO LIGHT POLE Strength Requirement: 3000 psi fc @ 28 Days Slump: 5.500" % Air: 4 .80% Mix Number: 13082 4 8 Conc. Temp: 7 1 Cement Type: I / I I Max Agg: 3/ 4 Admix/Amt: Cubic Yards: 30 Register Number: 0087778 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/29/2008 11/04/2008 44700 12.56 3560 2 RH2 28 10/29/2008 11/25/2008 28 10/29/2008 11/25/2008 28 10/29/2008 11/25/2008 El Distribute attachments. Average fc @ 28 days Please see reverse side for additional information. Job Number: T0806977. Register Number: 0087778 Date Molded: 10/28/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 < 1 in. [25 mm] )\\ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end f Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed - ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/05/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information.contained in this document. Inc. onstruction In & Related Tests Carlson Testing, nc• Geotechnical Consulting Main Office Salem Office . Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/28/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW . Subcontractor: Cast By: K. THRALL Concrete Supplier: CEMEX Truck #: 6573 Load #: 1 Ticket#: 22922652 Weather: SUNNY Test Time: 1: 30 PM Air Temp. at Sampling Time: 61 Cylinders were cast for the following locations: Total Concrete Placement Location: EAST PARKING SOUTH END Strength Requirement: 3000 p si fc @ 28 Days Slu mp: 6.000" % Air: 4.80% Mix Number: 130824 8 Conc. Temp: 7 1 Cement Type: I / I I Max Agg: 3/ 4 Admix/Amt: 10/20 + Cubic Yards: Register Number: 008777 9 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Recd Date Load PSI Fracture By II 7 10/29/2008 11/04/2008 42800 12.56 3410 3 RH2 28 10/29/2008 11/25/2008 28 10/29/2008 11/25/2008 28 10/29/2008 11/25/2008 El Distribute attachments. Average f c@ 28 days Please see reverse side for additional information. Job Number: T0806977- Register Number: 0087779 Date Molded: 10/28/2008 Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 — 1 1 1 0 X < 1 [25 mmj Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/05/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office Salem Office Bend Office P.O. Box 23814 .60 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684-3460 FAX (503) 684 -0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 1309 FAX (541) 330 -9163 SAMPLE DATA AND LABORATORY TEST REPORT OF CONCRETE CYLINDERS CTI Job # T0806977 PROJECT Tualatin Valley Fire & Rescue - Fire Station #50 CTI LABORATORY REGISTER NO 1520 HIGHWAY 12617 SW Walnut Street, Tigard COUNTY Washington DATA SHEET NO TECHNICIAN CARD NO. 44302 CONTRACTOR First Cascade Corporation - Michael Krecklow FA PROJECT NO. BID ITEM NO PROJECT MANAGER SUBMITTED BY Adam Rose / Carlson Testing Inc. - SAMPLE DATA • CONCRETE FOR USE IN (LOCATION OR PLACEMENT) BRIDGE NO STRENGTH REQUIRED _ Light Pole Base - _ 3300 PSI 28 DAY CONCRETE SUPPLIER Glacier Northwest FIELD TESTS BY Adam Rose #44302 REPRESENTED BY SET NO SIZE (in) DATE CAST DATE SHIPPED QCT (PLEASE PRINT) NO OF CYLINDERS 4 1 4X8 09/26/08 - Adam Rose #44302 TEST SPECIMENS AT DAYS INDICATED QCT SIGNATURE A. 7 B 281c 28ID 281E IF IG IH— t • MIX DESIGN LAB OR I D NO DESIGN DESIGN CEMENT + FLYASH CONTENT - FREE (SURFACE) MOISTURE % INFO 0342 3300 PSI 570 lb/yd 3 1 1/2 " -3/4 "• 0.50 3/4 " -#4: 0.00 SAND: 3.00 FIELD TEST CONCRETE TEMP. SLUMP AIR CONTENT UNIT WEIGHT CEMENT + FLYASH CONTENT FIELD W/C RATIO RESULTS 78 ° F 6 in 3 % 140.8 Ib /ft 562 lb/yd 0.41 BY WT. CONCRETE BATCH WEIGHTS ADDITIVES CEMENT FLYASH 1 1/2" -3/4' 3/4' -#4 SAND WATER WATER AT JOB 275 ozl 4235 lb 905 IbI 16580 IbI n/a IbI 11300 IbI 203 gall 0 gal INITIAL CURE OF LOW TEMP HIGH TEMP AMBIENT TEMP QUANTITY REPRESENTED BY SAMPLE CYLINDERS 62 ° F 83 ° F 73 ° F 9 yd Field Remarks: LAB USE ONLY BELOW LABORATORY REPORT TESTED ACCORDING TO DATE DATA SHEET RECEIVED DATE CYLINDERS RECEIVED AASHTO T22 (ASTM C39) • CYLINDER ID DATE OF AGE DAYS MAXIMUM LOAD SPECIMEN AREA STRENGTH (PSI) LAB REMARKS BREAK OBSERVED FAILURE BREAKS A 10/03/2008 7 43,500 12.49 3480 • Columnar Vertical Cracking (Both Ends) B 10/24/2008 28 57,800 12.49 . 4630 Diagonal Fracture C 10/24/2008 28 57,800 12.49 4630 Columnar Vertical Cracking (Both Ends) D 10/24/2008 28 53,600 12.49 4290 Cone (One End) W/ Veritcal Cracks E F G H Average 28 Day 4520 OO 0 FAIL CERTIFIED TECHNICIAN (PLEASE PRINT) COMPANY NAME URE DATE Marlowe Mings #43840 Carlson Testing Inc. 10/24/08 P /Prolecis/ General /2008rt0806977/0DOT /Con Reg #1520 (9- 26.08) JP CC: Tualatin Valley Fire & Rescue - Gary Wells •City of Tigard Building Division Lewis & Van Vleel Inc - Lance Cerny Peck Smiley Elllin Architects - Jeff Bringenberg 1ef flgpsearchs cam FuSI Cascade Corporation - Michael Krecklow CTI PROJECT MANAGER James F Hletpas Information contained herein is not to be reproduced, except in full, without prior authorization • Carls ®n Testing Inc• -- 'onstruction In & Related Tests Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard. Oregon 97281 Salem. Oregon 97301 Bend. Oregon 97708 Phone (503) 684 -3460 Phone(503)589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/27/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Cli TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast By: A. LEWIS Concrete Supplier: CEMEX Truck #: 6071 Load #: 2 Ticket#: 126153 Weather: CLEAR Test Time: 1:30 PM Air Temp. at Sampling Time: 71 Cylinders were cast for the following locations: PARKING AREA ON EAST SIDE OF STRUCTURE. Total Concrete Placement Location: SAME AS ABOVE NOTE: SET ONE WAS 6X12'S FABRICATED THIS MORNING. THIS IS SET 2 AND THEY ARE 4X8'S! • Strength Requirement: 3000 psi £c @ 28 Days Slump: 5.000" % Air: 1 . 90 Mix Number: 1308248 Conc. Temp: 65 Cement Type: I /II Max Agg• 1.0 Admix/Amt: Cubic Yards: 21 Register Number: 0087748 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By II 7 10/28/2008 11/03/2008 34983 12.56 2790 3 AF 28 10/28/2008 11/24/2008 28 10/28/2008 11/24/2008 28 10/28/2008 11/24/2008 El Distribute attachments. Average f'c @ 28 days Please see reverse side for additional information. Job Number: T0806977. Register Number: 0087748 Date Molded: 10/27/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 — < 1 in. [25 mm] ■ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/04/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. .:onstruction Inspections & Related Tests -- Carlson Testing, Inc. . Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 6 X 12 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 ,Date Molded: 10/27/2008 Job Number: T0806977 . . Permit #: BUP2008 -00022 Cli TUALATIN VALLEY FIRE & RESCUE — GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 • Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION — MICHAEL KRECKLOW Subcontractor: Cast By: A. LEWIS Concrete Supplier: CEMEX • Truck #: 24 62 Load #: 1 Ticket#: Weather: CLEAR Test Time: 8:05 AM Air Temp. at Sampling Time: 59 Cylinders were cast for the following locations: UNREINFORCED SIDEWALK ON EAST SIDE OF BUILDING. CYLINDERS CAST EAST AT • CONTRACTOR'S REQUEST. Total Concrete Placement Location: SAME AS ABOVE • • Strength Requirement: 3000 psi fc @ 28 Days Slump: 6.000" % Air: 1 . 90% Mix Number: 1308248 Conc. Temp: 62 Cement Type: I /II Max Agg: 1.0 Admix/Amt: Cubic Yards: 12 Register Number: 0087751 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/28/2008 11/03/2008 73900 28.18 2620 2 BR 28 10/28/2008 11/24/2008 28 10/28/2008 11/24/2008 28 10/28/2008 11/24/2008 0 Distribute attachments. Average f @ 28 days Please see reverse side for additional information. Job Number: T0 . Register Number: 0087751 Date Molded: 10/27/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < 1 in. [25 mm] /)\\\ i i ( ‘ I Type l Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. • Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 11/04/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office .alem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977 . Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative K. THRALL OBOA 347 was on site this date Oct. 28, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? ® Yes ❑ No ❑ N/A Name: MATT y Com an FIRST CASCADE 2. Monitored loads arriving at job site for correct: Company: Mix #: 1308248 2. Type of work: © Concrete ® Reinforcing Slump 6 . 0 % Air 4.8 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous ❑ Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field At precast shop 4. Inspected placing and consolidation of approx. 40 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? X 2. Forms clear of debris? SAME AS REINFORCING X 3. Type, grade, size, quantity, spacing and X - condition conform? 4. Verified forms will nominally result in hardened concrete of the required X cross - sectional dimensions. 5. Verified location of reinforcing steel, pipes, conduits and sleeves with respect to X minimum concrete cover. 6. Verified type and location of splices, length After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. REPORT SUMMARY 7. Verified support & anchorage of reinforcing steel in the forms. X 1. Work inspected was: ® Completed ❑ In progress 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications ❑ Shop drawings with regard to weld inspection, quantity, and .x ❑ RFI ❑ Design change El Submittal El N/A permits issued. 10. Verified cast in place anchors. X Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). ❑ Yes ID No © N/A EAST PARKING SOUTH END 4. Noncompliance item(s) were reinspected this date, details on following page(s). ❑ Yes No © N/A Conform ❑ Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. ❑ See additional report page(s). Distribute attachments. Page 1 of 1 • Daily Report of Reinforced Concr, For: 10/28/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/04/2008 KRT /ARR TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Main Office alem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Carlson 'Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 • Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD ' CTI representative K. THRALL OBOA 347 • was on site this date oct. 28, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. I. Mix Design approved? ® Yes ❑ No (2 N/A Name: MATT Company: FIRST CASCADE 2. Monitored loads arriving at job site for correct: P Mix #: 1318248 2. Type of work: © Concrete © Reinforcing Slump 5 . 5 % Air 4. 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous 0 Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field At precast shop 4. Inspected placing and consolidation of approx. 4 0 • cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? x 2. Forms clear of debris? SAME AS REINFORCING x 3. Type, grade, size, quantity, spacing and x condition conform? 4. Verified forms will nominally result in hardened concrete of the required x cross - sectional dimensions. 5. Verified location of reinforcing steel, pipes, conduits and sleeves with respect to x minimum concrete cover. 6. Verified type and location of splices, length x After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. REPORT SUMMARY 7. Verified support & anchorage of reinforcing x 1. Work inspected was: Completed In progress steel in the forms. p ® p p g • 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. © Approved plans and specifications ❑ Shop drawings 9. Verified structrual embedments in the forms with regard to weld inspection, quantity, and x 0 RFI 0 Design change ❑ Submittal ❑ N/A permits issued. 10. Verified cast in place anchors. x Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on • elevations (floors) and drawing details]: following page(s). ❑ Yes 0 No ® N/A EAST CURB LINE CATCH BASIN TO LIGHT POLE. 4. Noncompliance item(s) were reinspected this date, details REPORTY OF 9/27/2008 NOT ON SITE. on following page(s). E Yes El No © N/A Conform ❑ Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. 0 See additional report page(s). Distribute attachments. Page 1 of 1 Daily Report of Reinforced Concr, For: 10/28/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/04/2008 KRT /ARR TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF.BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Main Office .alem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281. Salem, Oregon 97301 Bend, Oregon 97708 Car 1 son Testing, Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative K. THRALL OBOA 347 was on site this date Oct. 29, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? ® Yes ❑ No 0 N/A Name: MATT Company: FIRST CASCADE 2. Monitored loads arriving at job site for correct: Mix #: 1308248 2. Type of work: © Concrete © Reinforcing 6 .0 % Slump /o Air 5.2 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous Ei Periodic Number of sets 1 Samples per set 4 • 5. Work performed: ® In the field ❑ At precast shop 4. Inspected placing and consolidation of approx. 4 0 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? X 2. Forms clear of debris? • SAME AS REINFORCING X 3. Type, grade, size, quantity, spacing and X condition conform? 4. Verified forms will nominally result in hardened concrete of the required X cross - sectional dimensions. 5. Verified location of reinforcing steel, pipes, .conduits and sleeves with respect to minimum concrete cover. 6. Verified type and location of splices, length X After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. REPORT SUMMARY 7. Verified support & anchorage of reinforcing • steel in the forms. X 1. Work inspected was: ® Completed ❑ In progress 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications El Shop drawings with regard to weld inspection, quantity, and X RFI ❑ Design change ❑ Submittal ❑ N/A • permits issued. 10. Verified cast in place anchors. X Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). ❑ Yes ❑ No ® N/A EAST DRIVE CENTER- SECTION FROM CATCH BASIN TO 4. Noncompliance item(s) were reinspected this date, details LIGHT POLE. on following page(s). ❑ Yes El No © N/A ❑ Conform 0 Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. Ej See additional report page(s). ❑ Distribute attachments. Page 1 of 1 Daily Report of Reinforced Concr. • For: 10/29/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: • In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/04/2008 • KRT /ARR TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM • • Main Office - 'tlem Office Bend Office P.O. Box 23814 4( .udson Ave., NE P.O. Box 7918 Tigard; Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Carlson Testing, Inc. Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Masonry Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS • Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD • CTI representative D. SUMINSKI OBOA 340 was on site this date Oct. 24, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) _ PO Number: SCOPE OF INSPECTION SAMPLING 1. Checked in with superintendent or client representative. 1. Grout mix design approved? ® Yes El No ❑ N/A Name: KLINGER MIX # 885 Company: CASCADE 2. Type of grout samples made? N /A 2. Type of work: © Grout Mortar Number of sets Samples per set ri Prism Reinforcing • Solid Grout Partial Grout 3. Mortar mix design approved? ❑ Yes ❑ No ® N/A Mortar Type 3. Work included: ® Sampling © inspection 4. Type of mortar samples made? N/A 4. Inspection was "IBC" ® Level 1 ❑ Level II ❑ N/A Number of sets Samples per set 5. Work performed: © In the field ❑ At precast shop 5. Type of prism samples made? GROUTED CMU UNIT INSPECTION Yes No N/A Number of sets 1 Samples per set 2 1. Reviewed previous inspection reports? X Location of material placement [to include grid lines, elevations 2. Verified material stored properly, appropriately, (floors) and drawing details]: and meet the requirements of the project? X • . - SAME AS REINFORCING 3. Verified placement of masonry units and x construction of mortar joints. 4. Verified size & location of structural elements. x 5. Verified cleanouts provided. x 6. Verified welding of resteel was inspected. Confirmed by: x 7. Verified protection of masonry during cold x (below 40F) or hot (above 90F) weather. REPORT SUMMARY 8. Resteel size, grade, spacing, splices, and x clearances conform? 1. Work inspected was: © Completed ❑ In progress 9. Verified test prisms contain the same masonry units, grout, and mortar as the building. x 2. Completed work inspected was in compliance with ® Approved plans and specifications ❑ Shop drawings 10. Verified structural embedments in the forms with regard to weld inspection, quantity, and x ❑ RFI 0 Design change 0 Submittal 0 N/A permits issued. Document #(s) Dated: . 11. Verified type, size and location of anchors. x • 12. Verified minimum dimensions of spaces 3. Noncompliance item(s) were noted this date, details on provided for placement of grout. x following page(s). El Yes El No ® N/A . 13. Verified grout space clean. x 4. Noncompliance item(s) were reinspected this date, details 14. Verified consolidation by mechanical on following page(s). L Yes El No © N/A vibration & reconsolidation after loss of x water. • ❑ Conform ❑ Remain in progress Description of structure inspected [to include grid lines, Report(s) findings were discussed and left with elevations (floors) and drawing details]: KLINGER SCREEN WALL GENERATOR ROOM, TRASH ENCLOSURE AND o f CASCADE SIGN CMU WALLS. Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. El See additional report page(s). El Distribute attachments. Page 1 of 1 Daily Report of Masonry For: 10/24/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 11/03/2008 DS /ARR • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Carlson Testing, Inc. .= onstruction I & Related Tests Geotechnical Consulting Main Office Salem Office Bend Office. P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 • Tigard, Oregon 97281 Salem Oregon 97301 Bend. Oregon 97708 Phone (503) 684 -3460 Phone(503)589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/15/2008 Job Number: T0806977. . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: M . LARSON Concrete Supplier: X Truck #: 6071 Load #: 1 Ticket#: 22915508 Weather: CLOUDY /COOL Test Time: 2 : 00 PM Air Temp. at Sampling Time: 62 Cylinders were cast for the following locations: • Total Concrete Placement Location: 3 LIGHT POLE BASES; 1 EAST, 1 WEST, AND 1 SOUTH OF BUILDING Strength Requirement: 3000 psi Cc @ 28 Days Slump: 4 . 250" % Air: 5.00% Mix Number: 1308248 Conc. Temp: 6 6 Cement Type: Max Agg: 3/ 4 Admix/Amt: AEA Cubic Yards: 5 Register Number: 0087993 Lab Location: TIGARD • Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/16/2008 10/22/2008 40955 12.49 3280 2 RH2 28 10/16/2008 11/12/2008 28• 10/16/2008 11/12/2008 28 10/16/2008 11/12/2008 • ❑ Distribute attachments. Average Cc @ 28 days Please see reverse side for additional information. • Job Number: T0806977. , Register Number: 0087943 Date Molded: 10/15/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 -- 6 < 1 in. [25 mm] • Type l Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less • end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end • f Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type I Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 10/23/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office alem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 • Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD • CTI representative M. LARSON OBOA 240 was on site this date Oct. 15, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? © Yes ❑ No ❑ N/A Name: MATT Com an FIRST CASCADE 2. Monitored loads arriving at job site for correct: pan Mix #: 1308298 2. Type of work: © C © Reinforcing Slump 4 % Air 5.0 • 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 X 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous ❑ Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field El At precast shop 4. Inspected placing and consolidation of approx. 5 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations (floors) and drawing details]: 1. Reviewed previous inspection reports? X 2. Forms clear of debris? SAME AS REINFORCING X 3. Type, grade, size, quantity, spacing and X condition conform? 4. Verified forms will nominally result in hardened concrete of the required X cross - sectional dimensions. 5. Verified location of reinforcing steel, pipes, conduits and sleeves with respect to X minimum concrete cover. 6. Verified type and location of splices, length After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. X 7. Verified support & anchorage of reinforcing REPORT SUMMARY steel in the forms. X 1. Work inspected was: ® Completed In progress 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications El Shop drawings with regard to weld inspection, quantity, and X ❑ RFI ❑ Design change ❑ Submittal ❑ N/A permits issued. 10. Verified cast in place anchors. X Document #(s) Dated: Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). ❑ Yes ❑ No M N/A 3 LIGHT POLE BASES 1 ON WEST SIDE, ONE ON EAST 4. Noncompliance item(s) were reinspected this date, details SIDE AND ONE ON SOUTH SIDE OF BUILDING. on following page(s). ❑ Yes ❑ No © N/A El Conform ❑ Remain in progress Report(s) findings were discussed and left with MATT Of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. El See additional report page(s). ❑ Distribute attachments. Page 1 of 1 Daily Report of Reinforced Concr, For: 10/15/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: • In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 10/23/2008 ML /ARR TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM 10/29/08 WED 09:45 FAX 503 601 8254 Carlson Geotechnical am. C G� r1 y^� y� Carlson �i�Q echniCal O. B ox Office 81 Salem Office Bend Office P.O. B ox 23814 4060 Hudson Ave., NE P.O. Box 7918 A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem. OR 97301 Bend, OR 97708 Geotechnical Consulting Phone (503) 6844460 Phone (503) 589.1252 Phone (541) 330.9155 Construction Inspection and Related Tests FAX (503) 670 -9147 FAX (503) 589 -1309 FAX (541) 330 -9163 6� � CGT No: G0602953.A Q,2 - 07) 22-- FIELD REPORT (3 Pages) DATE COVERED: October 28, 2008 PROJECT: TVFR Fire Station 50 "Walnut" ADDRESS: 12585 SW Walnut Street, Tigard, Oregon BY: M. David Irish WEATHER: Dark, --50 °F PURPOSE OF VISIT: Proof -Roll Observation Carlson Geotechnical (CGT) staff, David Irish, arrived on site at about 6:00 a.m. at the request of Mike with First Cascade Corporation. The purpose of my visit was to observe a proof -roll of the parking lot and driveway baserock. I met with Dave Roberts of DBEC Excavation & Construction at the site. PROOF-ROLL OBSERVATION With the exception of the northern section of parking spaces located along the east side of the Fire Station, I observed a proof -roll of the parking lot and driveway baserock located along the west, east and north side of the newly constructed TVFR Fire Station building. The concrete parking lot slab within the northern section of parking spaces located along the east side of the Fire Station had already been poured. The baserock consisted of a mixture of /< -inmch -minus and 1' -inch -minus crushed rock imported from Cobb Rock Products. Mr. Roberts indicated that up to 2 vertical feet of crushed rock had been placed since CGTs last site visit on October 17, 2008. Mr. Roberts indicated that the parking lot and driveway areas located along the east side of the Fire Station were at finished, planned, baserock elevation and the concrete slab would be poured today. Mr. Roberts also indicated that the remainder of the parking lot and driveway areas were within 3 inches of finished, planned, baserock elevation and the concrete slab for these areas would be poured at a future date. The proof -roll was performed using a fully loaded, tandem -axle, dump truck and revealed no significant signs of rutting or deflection /pumping of the baserock. Based on my observations the baserock within the parking lot and driveway areas proof - rolled today has been prepared in general accordance with CGT recommendations. 10/29/08 WED 09:45 FAX 503 601 8254 Carlson Geotechnical a002 TVFR Fire Station 50 Walnut' Tigard, Oregon CGT Project No. G0602953,A October 28, 2008 Page 2 of 3 CLOSURE I informed Mr. Roberts of my observations and recommended that, since the baserock in the areas of the parking lot and driveways where the concrete slab pour date is unknown could be disturbed by heavy construction traffic, the baserock in those areas should be re- compacted prior to the pouring of the parking lot and driveway concrete slabs. I left the site at about 6:45 a.m. Should you have any questions regarding this report, please contact us at (503) 601 -8250. Respectfully submitted; Carlson Geotechnical 69L-)c-i i 7 M. David Irish -I 'yan T. Houser, CEG Senior Engineering Assistant Senior Engineering Geologist Note: Our reports pertain to the locations observed at the time of our visit only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. ATATCHMENT: Site Plan DISTRIBUTION: Mr. Gary Wells, TVFR, FAX: 503.642.9655 Daniel Watkins, City of Tigard Building Department, FAX: 503.624.3681 Lance Cerny, Lewis & Van Vleet, FAX: 503.885.1206 Jeff Bringenberg, Peck Smiley Ettlin Architects, FAX: 503.248.0223 Michael Krecklow, First Cascade Corporation, FAX: 503.699.8985 Kendra Laminack, PBS Environmental, FAX: 360.696.9064 Matt, DBEC Excavation & Construction, FAX: 503.513.6254 • Main Office slem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 C arlson 'Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Reinforced Concrete • Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977 . Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD . CTl representative Y. VITRUK OBOA 770 was on site this date Oct. 08, 2008 to perform Special Inspection for: • Permit BUP2008 -00022 - DFS #(s) PO Number: SCOPE OF INSPECTION CONCRETE 1. Checked in with superintendent or client representative. 1. Mix Design approved? © Yes ❑ No 0 N/A Name: MATT Company: FIRST CASCADE 2. Monitored loads arriving at job site for correct: Mix #: 1308161 2. Type of work: © Concrete Reinforcing Slump 4 +/- 1 % Air 1. 3. Work included: © Sampling © Inspection 3. Type of samples made? 4 x 8 CONCRETE CYLINDERS 4. Inspection was 'IBC' © Continuous El Periodic Number of sets 1 Samples per set 4 5. Work performed: ® In the field p At precast shop 4. Inspected placing and consolidation of approx. 6 cubic yards of concrete. REINFORCING Yes No N/A Location of concrete placement [to include grid lines, elevations • (floors) and drawing details]: 1. Reviewed previous inspection reports? x 2. Forms clear of debris? SAME AS UNDER REINFORCING. x 3. Type, grade, size, quantity, spacing and x condition conform? 4. Verified forms will nominally result in hardened concrete of the required x • cross- sectional dimensions. 5. Verified location of reinforcing steel, pipes, conduits and sleeves with respect to x minimum concrete cover. 6. Verified type and location of splices, length X After samples are tested, results will follow on break report. of contact laps, and min. diameter of bends. REPORT SUMMARY 7. Verified support & anchorage of reinforcing steel in the forms. x 1. Work inspected was: ® Completed 0 In progress 8. Verified structural embedments in the forms x 2. Completed work inspected was in compliance with with regard to fabrication, quality and type. 9. Verified structrual embedments in the forms © Approved plans and specifications El Shop drawings with regard to weld inspection, quantity, and x RFI El Design change ❑ Submittal ❑ N/A permits issued. 10. Verified cast in place anchors. Document #(s) Dated: • Description of structure inspected [to include grid lines, 3. Noncompliance item(s) were noted this date, details on elevations (floors) and drawing details]: following page(s). El Yes ❑ No © N/A .FOOTINGS FOR PYLON SIGN (IN FRONT OF BLDG) , 4. Noncompliance item(s) were reinspected this date, details TRASH ENCLOSURE & 2 GENERATOR ENCLOSURES on following page(s). ❑ Yes No © N/A (NORTH /EAST OF BLDG), REFERENCE DETAIL A.1.2. ❑ Conform ❑ Remain in progress Report(s) findings were discussed and left with MATT of FIRST CASCADE Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. 0 See additional report page(s). ❑ Distribute attachments. Page 1 of 1 Daily Report of Reinforced Concr. For: 10/08/2008 CTI Job #: T0806977. Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, • CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 10/10/2008 YV /JWA TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Inc. • 'onstruction In & Related Tests C arlson Testing, nc• Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS , Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 10/08/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS . Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: Y . VITRUK Concrete Supplier: CEMEX Truck #: 24 59 Load #: 1 Ticket#: 1019672 6 Weather: CLEAR Test Time: 12:25 Air Temp. at Sampling Time: 53 Cylinders were cast for the following locations: SAME AS BELOW Total Concrete Placement Location: FOOTINGS FOR: PYLON SIGN TRASH ENCLOSURE AND TWO GENERATOR ENCLOSURES. Strength Requirement: 3000 psi Pc @ 28 Days Slump: 3.500" % Air: 1.40% Mix Number: 1308161 Conc. Temp: 62 Cement Type: I /11 Max Agg: 3/ 4 Admix/Amt: Cubic Yards: 6 Register Number: 0087281 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 10/09/2008 10/15/2008 42140 12.56 3360 3 RH2 28 10/09/2008 11/05/2008 28 10/09/2008 11/05/2008 28 10/09/2008 11/05/2008 • Distribute attachments. Average f c @ 28 days Please see reverse side for additional information. Job Number: T0806977. . Register Number: 0087281 Date Molded: 10/08/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 —♦ < 1 in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well- formed cones cracking through caps cone on other end .\ Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly tnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW MICHAELK @FIRSTCASCADE.COM FIRST CASCADE CORPORATION - MATT HUBEL MATTH @FIRSTCASCADE.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 10/16/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Main Office Salem Office Bend Office P.O. Box 23814 .60 Hudson Ave., NE P.O. Box 7918 I • Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 FAX (503) 589 -1309 Phone (541) 330 -9155 1 FAX (503) 684 -0954 FAX (541) 330-9163 SAMPLE DATA AND LABORATORY TEST REPORT • OF CONCRETE CYLINDERS CTI Job # T0806977 PROJECT "Tual Va Iey_F -&- Rescue— Fire - Station- #50 ----J CTI LABORATORY REGISTER NO 1520 . HIGHWAY 12617 SW Walnut Street, Tigard COUNTY Washington DATA SHEET NO TECHNICIAN CARD NO. 44302 CONTRACTOR First Cascade Corporation - Michael Krecklow FA PROJECT NO. BID ITEM NO PROJECT MANAGER SUBMITTED BY Adam Rose / Carlson Testing Inc. SAMPLE DATA CONCRETE FOR USE IN (LOCATION OR PLACEMENT) BRIDGE NO. STRENGTH REQUIRED Light Pole Base 3300 PSI 28 DAY CONCRETE SUPPLIER Glacier Northwest FIELD TESTS BY Adam Rose #44302 REPRESENTED BY SET NO. SIZE (in) DATE CAST DATE SHIPPED QCT (PLEASE PRINT) NO OF CYLINDERS 4 1 4X8 09/26/08 Adam Rose #44302 TEST SPECIMENS AT DAYS INDICATED QCT SIGNATURE A. . 7 B. 28Ic 28ID. 281E. IF IG• IH.- MIX DESIGN LAB OR I.D. NO. DESIGN DESIGN CEMENT + FLYASH CONTENT FREE (SURFACE) MOISTURE % - INFO 0342 3300 PSI 570 lb/yd 1 1/2 " - 3/4 ": 0.50 3/4 " 0.00 SAND: 3.00 FIELD TEST CONCRETE TEMP. SLUMP AIR CONTENT UNIT WEIGHT CEMENT + FLYASH CONTENT FIELD W/C RATIO RESULTS 78 ° F 6 in 3 % 140.8 Ib /ft 562 lb/yd 0.41 BY WT. CONCRETE BATCH WEIGHTS ADDITIVES CEMENT FLYASH 11/T-3/4" 3/4 "-#4 SAND WATER WATER AT JOB 275 ozl 4235 lb 905 IbI 16580 IbI n/a IbI 11300 IbI 203 gall 0 gal INITIAL CURE OF LOW TEMP HIGH TEMP AMBIENT TEMP QUANTITY REPRESENTED BY SAMPLE CYLINDERS 62 ° F 83 ° F 73 ° F 9 yd Field Remarks: LAB USE ONLY BELOW I LABORATORY REPORT TESTED ACCORDING TO DATE DATA SHEET RECEIVED DATE CYLINDERS RECEIVED AASHTO T22 (ASTM C39) CYLINDER ID DATE RF AGE DAYS MAXIMUM LOAD SPECIMEN AREA STRENGTH (PSI) LAB REMARKS OBSERVED FAILURE BREAKS A 10/03/2008 7 43,500 12.49 3480 - Columnar Vertical Cracking (Both Ends) B 10/24/2008 28 C 10/24/2008 28 D 10/24/2008 28 E F G H Average 28 Day ® PASS 0 FAIL CERTIFIED TECHNICIAN (PLEASE PRINT) COMPANY NAME ViTURE DATE Marlowe Mings #43840 Carlson Testing Inc. 10/03/08 PlProlects/ Genera1/2008rr08o6977/0DOT /ConReg #1520 (9- 26-08) ip CC: Tualatin Valley Fire & Rescue - Gary Wells City of Tigard Building Division / Lewis & Van Vleet Inc - Lance Cerny Peck Smiley Ettlin Architects - Jeff Bringenberg 7eff @psearchs. com First Cascade Corporation - Michael Krecklow -- -it- - CTI PROJECT MANAGER Arih ":11111P • � James F. Hietpas Information contained herein Is not to be reproduced, except In f h out prior authorization. 4 onstruction Inspections & Related Tests C arlson Testing Inc. , Geotechnical Consulting Main Office Salem Office Bend Office'-' P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 =:, Tigard. Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRET TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 06/12/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 'Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: K. BARNETT Concrete Supplier: CEMEX Truck #: 7664 Load #: 1 Ticket#: 22834 0 3 8 Weather: PARTLY CLOUDY, COOL Test Time: 8:20 Air Temp. at Sampling Time: 55 Cylinders were cast for the following locations: SLAB ON GRADE AT APPROXIMATELY D -2 Total Concrete Placement Location: SLAB ON GRADE D -E, 1 -3 Strength Requirement: 3500 psi t'c @ 28 Days Slump: 4.000" % Air: 1.70% Mix Number: 1308184 Conc. Temp: 65 Cement Type: 1 -II Max Agg: 3/4 - - Admix/Amt: Cubic Yards: Register Number: 008427 4 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By 7 06/13/2008 06/19/2008 49100 12.56 3910 4 MEM 28 06/13/2008 07/10/2008 70400 12.56 5610 3 MEM 28 06/13/2008 07/10/2008 74200 12.56 5910 3 MEM 28 06/13/2008 07/10/2008 75800 12.56 6040 2 MEM ID Distribute attachments. Average l'c @ 28 days 5850 Please see reverse side for additional information. T 0806977. 00842 0'6'/12/2008 Job Number: Aegister Numb Date M olded:- Project: TUALATIN VALLEY FIRE & RESCUE – FIRE STATION #50 — < 1 in. [25 mm] X /)\\ ;11\ i 1 Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, Tess end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well- formed cones cracking through caps cone on other end \ . _ f i Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly :nd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toller On 07/11/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • I Capls ®n Testing, Inc. onstruction Inspections & Related Tests Geotechnical Consulting Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave.. NE P.O. Box 7918 Tigard, Oregon 97281 Salem. Oregon 97301 Bend, Oregon 97708 " Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 06/13 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project : TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD . Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Subcontractor: ARRIETA' S CONCRETE Cast By: J. HALL Concrete Supplier: CEMEX Truck #: 7664 Load #: 2 Ticket#: 1016 5 5 2 9 Weather: PARTLY CLOUDY, MILD Test Time: 8 : 55 AM Air Temp. at Sampling Time: 66 Cylinders were cast for the following locations: SLAB ON GRADE AREA C /D -1/3 • Total Concrete Placement Location: SLAB ON GRADE AREA E /G -1/3, TRASH ENCLOSURE FOOTINGS SPREAD FOOTINGS G/D - SOUTH OF 3 AND TRENCH DRAINS BOTTOM FOOTINGS AT CENTER OF BUILDING Strength Requirement: 3500 psi f c @ 28 Days Slump: 4.500" % Air: 1.00% Mix Number: 1308184 Conc. Temp: 7 6 Cement Type: I - I I Max Agg: 3 / 4 Admix/Amt: 10/20 Cubic Yards: Register Number: 0084315 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By I 7 06/16/2008 06/20/2008 54400 12.56 4330 4 MEM 28 06/16/2008 07/11/2008 73500 12.56 5850 2 MEM • 28 06/16/2008 07/11/2008 78000 12.56 6210 3 MEM 28 06/16/2008 07/11/2008 66900 12.56 5330 4 MEM Distribute attachments. Average fc 2 8 days 5800 Please see reverse side for additional information. Job Number: T0806977. Register Number: 0084315 Date Molded: 06/13/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 < l in. [25 mm] Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends. Tess end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well- defined well - formed cones cracking through caps cone on other end Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly .nd of cylinder is pointed ends: tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW • Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toller On 07/14/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Carlson Testing, Inc. { onstruction In & Related Tests Geotechnical Consulting . Main Office Salem Office Bend Office • P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS • TestMethods• ASTM C31 /C172/C192/C617/C1064/C231/C143 Date Molded: 06/11/2008 Job Number: T0806977 . Permit #: BUP2008 -00022 Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project : TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE CORPORATION - MICHAEL KRECKLOW • Subcontractor: Cast By: L. WARFIELD Concrete Supplier: CEMEX Truck #: 7664 Load #: 1 Ticket#: 22832965 Weather: OVERCAST Test Time: 8 : 15 AM Air Temp. at Sampling Time: 52 Cylinders were cast for the following locations: NORTH END OF SLAB SECTION NOTED Total Concrete Placement Location: SLAB ON GRADE, GRID A -C, 1 -3 Strength Requirement: 3500 psi fc @ 28 Days Slump: 5.000" % Air: 1. 60% Mix Number: 1308184 Conc. Temp: 63 Cement Type: 1 -II Max Agg: 1 Admix/Amt: 10 / 3 0 • Cubic Yards: Register Number: 0084227 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By 7 06/12/2008 06/18/2008 51600 12.56 4110 4 DH 14 06/12/2008 06/25/2008 59000 12.56 4700 3 MEM 28 06/12/2008 07/09/2008 68900 12.56 5490 4 MEM 28 06/12/2008 07/09/2008 67300 12.56 5360 4 MEM 0 Distribute attachments. Average f c@ 28 days 54 30 ' Please see reverse side for additional information. Job Number: T0806977. ttegister Number: 0084227 Date Molded: 06/11/2008 Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 • -- 1 1 b X< 1 in. [25 mm] /)\\ ; Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well- defined well - formed cones cracking through caps cone on other end • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toller On 07/11/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. onstruction Inspections & Related Tests C Testing, Inc. Geotechnical Consulting Main Office Salem Office ' Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 ' Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 • Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 • REPORT OF 4 X 8 CONCRETE TEST SPECIMENS . Test Methods: ASTM C31 /C172/C192/C617/C1064/C231/C143 • Date Molded: 06/20/2008 Job Number: T0806977. Permit #: BUP2008 -00022 Client: TUALATIN FIRE & RESCUE - GARY WELLS . • Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 • Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD Contractor: FIRST CASCADE. CORPORATION - MICHAEL KRECKLOW Subcontractor: Cast By: K. BARNETT Concrete Supplier: CEMEX Truck #: 573 Load #: 2 Ticket#: 22840397 Weather: CLEAR, COOL Test Time: 8:00 AM Air Temp. at Sampling Time: 60 Cylinders were cast for the following locations: ' SLAB ON GRADE 2.8 -C.8 Total Concrete Placement Location: SLAB ON GRADE 2.5 -3, C -D Strength Requirement: 3000 psi Pc @ 28 Days Slump: 5.750" % Air: 2.10% Mix Number: 1308184 Conc. Temp: 7 3 Cement Type: 1 1 1 Max Agg: 3/4 Admix/Amt: Cubic Yards: Register Number: 0084583 Lab Location: TIGARD • Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By 7 06/23/2008 06/27/2008 49300 12.56 3930 4 DH • 28 06/23/2008 07/18/2008 62500 12.56 4980 2 WR 28 06/23/2008 07/18/2008 64600 12.56 5140 2 WR 28 06/23/2008 07/18/2008 66700 12.56 5310 2 WR ❑ Distribute attachments. Average f c @ 28 days 5140 Please see reverse side for additional information. Job Number: T0806977 . Register Number: 0084583 Date Molded: 06/20/2008 Project: TUALATIN VALLEY FIRE & RESCUE — FIRE STATION #50 -- 11 0 < 1 in. [25 mm] )\\ 7 g1 \ Type 1 Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end • Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. . . Remarks: • • • TUALATIN VALLEY FIRE & RESCUE - GARY WELLS - TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toller On 07/21/2008 Our report pertains to the material tested only. The information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. • • Main Office lem Office Bend Office P.O. Box 23814 40601`fudson Ave., NE P.O. Box 7918 , • Tigard, Oregon 97281 Salem, Oregon 97301 Bend, Oregon 97708 - Carlson Testing, Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330-9155 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541)330 -9163 Daily Report of Structural Steel •Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative J. KING OBOA 416 was on site this date Sep. 04, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION Location of steel inspection [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent, client or shop rep. Name: MATT FILLET WELDS ON 1" X 1/4" X 8" BAR TO BASE Company: FIRST CASCADE PLATE 2. Inspection was "IBC" ❑ Continuous © Periodic FIXES TO COLUMN CAPS AT 12 COLUMNS 3. -Work performed: © In the field ❑ At fab shop • 4. If shop inspection do they have fabrication and QC procedures? ❑ Yes ❑ No © N/A INSPECTION - Yes NoN /A 1. Reviewed previous inspection reports? X 2. Verified steel materials are in compliance by reviewing random samples of the mill test reports, steel ID X markings or other documentation. 3. Verified weld filler materials conform. X 4. Checked steel members to see they were fabricated and ' erected in accordance with the workmanship and X tolerances required. '5. Checked welded studs and structural connections were REPORT SUMMARY installed as required. X 6. Verified high strength bolts and fasteners conform. x 1. Work inspected was: © Completed ❑ In progress 7. Verified the quality of welds produced by welders, 2. Completed work inspected was in comp liance with • w elding operators, and tackers conform. X P P P 8. Verified steel frame joint details for bracing, stiffening, ❑ Approved plans and specifications ❑ Shop drawings member locations, and application of joint details at each X RFI El Design change El Submittal ❑ N/A connection are in compliance by random sampling. Document #(s) DTL A PER ENG INSP Dated: 08/07/08 • WELDER INFORMATION 3. Noncompliance item(s) were noted this date, details on Welders Name: TED OVERHOLT following page(s). ❑ Yes ❑ No © N/A Certification #: ON FILE 4. Noncompliance item(s) were reinspected this date, details • Yes No N/A on following page(s). ❑ Yes ❑ No © N/A 1. Verified the contractor's Welding Procedure Specifications are in conformance with X El C onform Remain in progress ❑ P g AWS requirements. • 2. Verified the essential variables outlined in the Report(s) findings were discussed and left with Welding Procedure Specifications were X MATT employed during execution of the work. o f FIRST CASCADE 3. Verified the weldability of reinforcing steel Based on the Code, approval is required from the Building Official before the other than ASTM A706. X SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. ❑ See additional report page(s). ❑ Distribute attachments. Page 1 of 1 Daily Report of Structural Steel For: 09/04/2008 CTI Job #: T0806977 . Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: • • In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, • CARLSON TESTING, INC. James Hietpas Reviewed By: Steven W Leach Project Manager Review Date: 09/11/2008 JK /CK TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW Main Office - Salem Office Bend Office • P.O. 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, Oregon 9 Carls ®n Testing, Inc. Bend, Oregon Phone (503)684 -3460 Phone (503)589 -125125 2 Phone (541)330 -9150-915 5 Fax (503) 684 -0954 Fax (503) 589 -1309 Fax (541) 330 -9163 Daily Report of Proprietary Anchors •Client: TUALATIN VALLEY FIRE & RESCUE - GARY WELLS Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 CTI Job #: T0806977. • Address: 12617 SW WALNUT STREET TIGARD OR Jurisdiction: TIGARD CTI representative A. NUNLEY OBOA 866 was on site this date Aug. 06, 2008 to perform Special Inspection for: Permit BUP2008 -00022 DFS #(s) PO Number: SCOPE OF INSPECTION - Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. OBSERVED THE INSTALLATION OF 23 VERT 3/4" Name: MATT THREADED ROD 13/16" DIA WITH 9 "•EMBEDMENT PER Company:. F -IRST CASCADE 9/S1.2 BASE PLATE DETAIL, GRID LINES 2 /C -D (11) • & 3 /C -D 912). 2. was "IBC" © Continuous El Periodic NOTE: 1 WAS NOT DRILLDNEEDS TO BE DONE AT A PROPRIETARY ANCHORS LATER DATE. e ( W /V e i • Yes No N /AC previous inspection reports? _ J_!. ' A44 1. Reviewed P P P x 2. Reviewed evaluation report? x Verified following items meet manufacturer's REPORT SUMMARY published installation instructions. 3. Verified minimum embedment depth of the 1. Work inspected was: ® Completed ❑ In progress • anchors. x 4.Verified installation of the anchors. 2. Completed work inspected was in compliance with x ® Approved plans and specifications ❑ Shop drawings 5. Verified anchor diameter. x 6. Verified steel grade. x ❑ RFI ❑ Design change ❑ Submittal ❑ N/A 7. Verified hole diameter. x Document #(s) Dated: 8. Verified type of drill bit used. x 9. Verified hole cleaning method. x 3. Noncompliance item(s) were noted this date, details on 10. Verified. adhesive application. x following page(s). Yes No ®N /A 11. Verified edge distance. x 4. Noncompliance item(s) were reinspected this date, details 12. Verified spacing. x on following page(s). ❑ Yes ❑ No ® N/A 13. Verified installation torque. x ❑ Conform ❑ Remain in progress Evaluation report number & date: Report(s) findings were discussed and left with . ESR -1967 • MATT 12 -01 -05 o f FIRST CASCADE Name of product being installed HILTI HY -150 Batch Number 073622L4 Expiration Date 11 - 08 Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can • be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. ❑ See additional report page(s). Page of ❑ Distribute attachments. 1 1 Daily Report of Proprietary Anchors For: 08/06/2008 CTI Job #: T0806977. - Project: TUALATIN VALLEY FIRE & RESCUE - FIRE STATION #50 Notes: • • In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: James Hietpas Review Date: 08/15/2008 ALN /JWA TUALATIN VALLEY FIRE & RESCUE - GARY WELLS TO: CITY OF TIGARD BUILDING DIVISION LEWIS & VAN VLEET INC - LANCE CERNY PECK SMILEY ETTLIN ARCHITECTS - JEFF BRINGENBERG JEFF @PSEARCHS.COM FIRST CASCADE CORPORATION - MICHAEL KRECKLOW