Correspondence °93 -a0 /9 66-3 ie. C TUALATIN VALLEY FIRE & RESCUE ' AND c.,•1_--,,,,,, BEAVERTON FIRE DEPARTMENT U J 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, OR 97076 • (503) 526 -2469 • FAX 526 -2538 RF &RES , October 20, 1993 SSOE, Inc. 1050 Wilshire Dr., Suite 260 Troy, Michigan 48084 Re: Mervyn's Washington Square Mall 9400 S.W. Washington Square Road Tigard, Oregon 97223 5889C- 060 -106 Gentlemen: This is a Fire and Life Safety Plan Review and is based on the 1991 editions of the Uniform Fire Code (UFC) and those sections of the Uniform Building Code (UBC) and Uniform Mechanical Code (UMC) specifically referencing the fire department, and other local ordinances and regulations. Plans reveiwed by this office are acceptable as sub- mitted, subject to the following: Plans referred to and examined by this office contain no provisions for the alteration or installation of automatic sprinkler system. Not less than three sets of plans for the installation shall be submitted to this office for approval prior to installation. UBC 302(b) Approval of submitted plans is not an approval of omissions or oversights by this office or of non- compliance with any applicable regulations of local government. "Working" Smoke Detectors Save Lives !; SSOE, Inc. October 20, 1993 Page 2 If I can be of any further assistance to you, please feel free to contact me at 526 -2502. Sincerely, ene Birchill, DFM Plans Examiner GB:kw ` cc: City of Tigard Building Department .L 9'3 -o19 9 9 ' n ;, C > r '� TUALATIN VALLEY FIRE & RESCUE ; : c 41; . 1 AND <� "`v .. ' BEAVERTON FIRE DEPARTMENT 9;1 U GJ +' 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, OR 97076 • (503) 526 -2469 • FAX 526 -2538 F & RES September 28, 1993 Robert B. Polk 3 -D Protection Systems, Inc. 0110 S.W. Porter Street Portland, Oregon 97201 Re: Retro Fit Alarm System Upgrade Washington Square 9400 S.W. Washington Square Road 5889C- 060 -000 Dear Mr. Polk: This is a Fire and Life Safety Plan Review and is based on the 1991 editions of the Uniform Fire Code (UFC) and those sections of the Uniform Building Code (UBC) and Uniform Mechanical Code (UMC) specifically referencing the fire department, and other local ordinances and regulations. Plans submitted to this office for review and approval of the above noted fire alarm system are conditionally approved, subject to the following: Based on a test to occur of visual fire alarms, additional visual devices may be required to be installed. This is based on Uniform Building Code Section 3109(n)2 Paragraph 3 dealing with spaces exceeding 100 feet in horizontal dimension and requiring visual alarms placed around the perimeter of said area. If the demonstration test reveals that adequate illumination is provided, system may be installed in accordance with submitted plans, otherwise additional visual alarms will need to be installed. This Plans Examiner is somewhat confused by single tamper flow switches at multiple locations as there are multiple valves and risers at each one of these "Working" Smoke Detectors Save Lives r Robert B. Polk September 28, 1993 Page 2 automatic sprinkler system locations. If the old system is to be removed and the new system to be put on, then each riser shall have a flow switch and each valve shall be supervised. A member of this office shall witness all tests. Please provide 24 hour notification prior to anticipated test times. Once the system has been installed, completed, and tested, a Completion Certificate shall be filled out and forwarded to this office. Please note Completion Certificate is located in National Fire Protection Association Standard 72. Approval of submitted plans is not an approval of omissions or oversights by this office or of non- compliance with any applicable regulations of local government. If I can be of any further assistance to you, please feel free to contact me at 526 -2502. Sincerely, dP' Gene Birchill, DFM Plans Examiner GB:kw cc: City of Tigard Building Department